Loading…
Loading…
Tender Value
₹1.6 Cr
EMD Value
₹3.2 L
Closing Date
30 Jul 2026, 3:30 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SRDSTE/RJT
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. NOTE: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated / registered atleast 5 years prior to the date of opening of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Definition of similar nature of work: - Any signaling work involving outdoor work and/or addition and/or alteration in existing indoor signaling system OR any CLS or RI or EI or TPWS or IBS or ABS or BPAC work involving Indoor and /or Outdoor work. Similar work to include indoor if the tendered work involves addition and/or alteration in existing indoor signaling system and outdoor if the tendered work involves outdoor work OR any such work involving activities as given in the name of tendered work.
18 conditions · 2 needing a document upload
1.EMD/Bid security is deposited as per Clause 5 of Part I ""regulations for tenders and contract " of tender document. 2. EMD need to be deposited online on www.ireps.gov.in. 3. For the tenders costing upto 50 Lakhs: - No technical and financial credentials required but firm's documents and any other mandatory documents which are demanded in tender are require to be submit at the time of bidding. 4. tender having value more than 50 Lakhs: - Financial and technical credentials required as per GCC applicable and firm's documents and any other mandatory documents which are demanded in tender are require to be submit at the time of bidding.
1. If Tenderer is sole proprietor: Affidavit on Stamp paper of appropriate value declaring that his/her concern is a Proprietary concern or any other documents such as GST Certificate, PAN Card of firm Name etc. is to be submitted. 2. If Tenderer is partnership firm: Notarized partner ship deed Original/Notarized power of attorney. 3. If Tenderer is JV/Limited Company: Copy of Memorandum and Articles of Association of the company. Power of Attorney (duly registered/ notarized as per prevailing law) by the company authorizing the person to do/act on behalf of the company. 4. If Tenderer is Company: Copies of MOA (Memorandum of Association) & AOA (Articles of Association) of the company. Power of attorney duly registered/notarized by the company in favour of the individual signing the tender on behalf of the company. Resolution of Board of directors in regards of approving Power of attorney issued. 5. If Tenderer is Society: Attested copy of the certificate of registration. Deed of formation. Power of attorney in favour of the tender signatory. 6. Copy of PAN number and TIN number.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Rajkot Division-Signalling work in connection with Engg work of (i)TTR(TWS+WCMSC) 21 sets (ii)RJT-OKHA- CTR(P)-4.190 Tkm & TRR(P)-25.155Tkm (iii)JAM-KNLS Section: CTR(P) From Kms.848.886 to 850.700 Total 1.814 Kms (iv)Viramgam - Rajkot, Wankaner - Navlakhi & Surendranagar - Botad- CTR(P)- 4.013 Tkm, TRR(P)-8.982 Tkm and TSR(P)-50.74 Tkm(v) Kanalus: Rectification of bad layout from Pt 112 towards PBR side by shifting the turnout manually by 18m towards RJT.
DRM-RJT-26-27-SnT-E-10
DRM-RJT-26-27-SnT-E-10
Open
Works - General
12 Months
Rajkot, Gujarat
₹0
₹3.2 L
30 Jul 2026
8 Jul 2026
16 Jul 2026
363 items across 11 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 13,92,332.05 | ||
| — | 5.00 | — | — | ||
| Track Lead Junction Boxes as per C.Rly Drg. No. RST 11509 made from fiber glass along with terminal blocks. | — | — | — | 5,603.25 | |
| — | 500.00 | — | — | ||
| Channel Pins MS (Galvanized) single groove, 7 mm suitable for 4mm dia bonding wire as per spec No IRS S 17 & RDSO Drg No. S-69/M. | — | — | — | 3,020 | |
| — | 500.00 | — | — | ||
| GI wire 8 SWG (4mm dia) suitable for track circuit rail bonding. | — | — | — | 34,085 | |
| — | 10.00 | — | — | ||
| Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & antioxidant and non flame propagating type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified. | — | — | — | 19,122 | |
| — | 20.00 | — | — | ||
| Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes. | — | — | — | 5,649.2 | |
| — | 5.00 | — | — | ||
| Track feed battery chargers, 110V AC input, 2 to 6 V DC Output; as per Specn.No.IRS.S 89/ 2013 with latest amendments. Charger shall be suitable for charging 80 AH battery. | — | — | — | 17,616.35 | |
| — | 3.00 | — | — | ||
| PVC jacketed wire rope for Track Lead connections. PVC jacketed wire ropeshould be of Galvanized steel wire rope 6 mm dia (6x19 stranded wire with steel core of 6 mm dia) heathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1970. Reclaimed or recycled material hould not be used. | — | — | — | 16,659.51 | |
| — | 100.00 | — | — | ||
| Point insulation Complete set as per RDSO Specification IRS: S-40/84 for L-Bracket, Switch bracket, Split-Stretcher bar & Gauge tie plates etc. (52Kg/60Kg as per site requirement) | — | — | — | 1,34,593 | |
| — | 30.00 | — | — | ||
| Relay, AC Immune, plug-in-type, Style 'QTA2', DC Neutral track, 9 ohm DC 2F. 1B contacts, front and back contacts metal to carbon, complete with plug board, retaining clip & connectors confirming to BRS:939A, BRS:966 (Appendix F2), IRS:S 34 & IRS:S 23 & 60 (as applicable). | — | — | — | 1,46,367 | |
| — | 21.00 | — | — | ||
| Miniature, Plug-in Type, DC Neutral Line Magnetically Latched Relay, Style QL1, 24 V DC, 11F-4B Contact, Code ABDEG Spec: BRS:935A ; IRSS 34 ; IRS S 23. | — | — | — | 1,55,199.24 | |
| — | 21.00 | — | — | ||
| Plug in Type, Tractive Armature, AC Immunized, DC Biased Contactor Relay, Style QBCA1,2HF-4B Contact,24 V DC, Code BCEJK Spec:BRS:943 ; IRS S 34 ; IRS S 23 ;IRSS 60-78. | — | — | — | 1,55,267.28 | |
| — | 200.00 | — | — | ||
| ARA Terminal blocks with links made of PBT Spec No.s/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4. | — | — | — | 15,000 | |
| — | 200.00 | — | — | ||
| Termination of outdoor cables, main cables laid in location boxes, Cable termination rack etc at both ends on ARA terminal or on 8 way terminals or on screw less connectors. Both ends of a cable core terminated shall be counted as one terminal. This includes all associated works of pulling out the cable from underground, peeling off insulation, dressing of cable core supported on sting rod with contractor's own material. The work shall be done as per instructions of Rly engineer at site. | — | — | — | 4,740 | |
| — | 20.00 | — | — | ||
| Excavation of cable trench as per cable route plan,1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtrs wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m. | — | — | — | 16,780 | |
| — | 50.00 | — | — | ||
| Horizontal direction drilling/boring without damage of surface road using Auger Machine. The bore shall be 150 mm dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtrs long. this include insertion of different dia DWC pipe/ GI pipes coupling etc. as per direction of Engineer In charge. Note:- Pipe will be supplied by railway. Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. | — | — | — | 59,392.5 | |
| — | 2000.00 | — | — | ||
| Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P.(Cables will be maggered before and after its laying by contractor under supervision of Railway Representative and he will submit the maggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. | — | — | — | 18,740 | |
| — | 5.00 | — | — | ||
| Erection, Fitting and Rail connection of Track Lead Junction Box on two supports (M.S.angle) with contractor's fixing material and PVC jacketed wire for track lead connection including angles of size 40 x 40 x 5 mm 1200 mm length. This will include drilling of holes for track lead/side connections on rail. The work shall be done as per Drg. No. S&T/Const./JHS/T 115 & instructions of Rly engineer at site. | — | — | — | 6,956.55 | |
| — | 100.00 | — | — | ||
| — | 2.00 | — | — | ||
| — | 21.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
DRM-RJT-26-27-SnT-E-10-GCC2022uptoACS11.pdf
ATTACHMENT
SpecialconditionofcontractCTRTTRwork.pdf
ATTACHMENT
ACSUPTO11_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].