Loading…
Loading…
Tender Value
₹1.6 Cr
EMD Value
₹3.2 L
Closing Date
30 Jul 2026, 3:30 pm
Rajkot Division-Signalling work in connection with Engg work of (i)TTR(TWS+WCMSC) 21 sets (ii)RJT-OKHA- CTR(P)-4.190 Tkm & TRR(P)-25.155Tkm (iii)JAM-KNLS Section: CTR(P) From Kms.848.886 to 850.700 Total 1.814 Kms (iv)Viramgam - Rajkot, Wankaner - Navlakhi & Surendranagar - Botad- CTR(P)- 4.013 Tkm, TRR(P)-8.982 Tkm and TSR(P)-50.74 Tkm(v) Kanalus: Rectification of bad layout from Pt 112 towards PBR side by shifting the turnout manually by 18m towards RJT.
DRM-RJT-26-27-SnT-E-10
DRM-RJT-26-27-SnT-E-10
Open
12 Months
Surendranagar, Gujarat
₹0
₹3.2 L
8 Jul 2026
8 Jul 2026
16 Jul 2026
A1-Supply Items [TTR (TWS+WCMSC) 21 sets]
Track Lead Junction Boxes as per C.Rly Drg. No. RST 11509 made from fiber glass along with terminal blocks.
Channel Pins MS (Galvanized) single groove, 7 mm suitable for 4mm dia bonding wire as per spec No IRS S 17 & RDSO Drg No. S-69/M.
GI wire 8 SWG (4mm dia) suitable for track circuit rail bonding.
Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & antioxidant and non flame propagating type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia. (The 4 manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified.
Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes.
Track feed battery chargers, 110V AC input, 2 to 6 V DC Output; as per Specn.No.IRS.S 89/ 2013 with latest amendments. Charger shall be suitable for charging 80 AH battery.
PVC jacketed wire rope for Track Lead connections. PVC jacketed wire ropeshould be 7 of Galvanized steel wire rope 6 mm dia (6x19 stranded wire with steel core of 6 mm dia) heathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1970. Reclaimed or recycled material hould not be used.
Point insulation Complete set as per RDSO Specification IRS: S-40/84 for L-Bracket, Switch bracket, Split-Stretcher bar & Gauge tie plates etc. (52Kg/60Kg as per site requirement)
Relay, AC Immune, plug-in-type, Style 'QTA2', DC Neutral track, 9 ohm DC 2F. 1B 9 contacts, front and back contacts metal to carbon, complete with plug board, retaining clip & connectors confirming to BRS:939A, BRS:966 (Appendix F2), IRS:S 34 & IRS:S 23 & 60 (as applicable).
Miniature, Plug-in Type, DC Neutral Line Magnetically Latched Relay, Style QL1, 24 V DC, 11F-4B Contact, Code ABDEG Spec: BRS:935A ; IRSS 34 ; IRS S 23.
Plug in Type, Tractive Armature, AC Immunized, DC Biased Contactor Relay, Style QBCA1,2HF-4B Contact,24 V DC, Code BCEJK Spec:BRS:943 ; IRS S 34 ; IRS S 23 ;IRSS 60-78.
ARA Terminal blocks with links made of PBT Spec No.s/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4. Per
Termination of outdoor cables, main cables laid in location boxes, Cable termination 13 rack etc at both ends on ARA terminal or on 8 way terminals or on screw less connectors. Both ends of a cable core terminated shall be counted as one terminal. This includes all associated works of pulling out the cable from underground, peeling off insulation, dressing of cable core supported on sting rod with contractor's own material. The work shall be done as per instructions of Rly engineer at site.
Excavation of cable trench as per cable route plan,1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtrs wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route 14 from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m.
Horizontal direction drilling/boring without damage of surface road using Auger Machine. The bore shall be 150 mm dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. 15 The length of the bore shall be minimum 4 Mtrs long. this include insertion of different dia DWC pipe/ GI pipes coupling etc. as per direction of Engineer In charge. Note:- Pipe will be supplied by railway. Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item 16 includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P.(Cables will be maggered before and after its laying by contractor under supervision of Railway Representative and he will submit the maggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.
Erection, Fitting and Rail connection of Track Lead Junction Box on two supports (M.S.angle) with contractor's fixing material and PVC jacketed wire for track lead connection including angles of size 40 x 40 x 5 mm 1200 mm length. This will include drilling of holes for track lead/side connections on rail. The work shall be done as per Drg. No. S&T/Const./JHS/T 115 & instructions of Rly engineer at site. Running
Provision of bonding with GI wire 4mm dia ( 8 SWG) for track jumper & fish plate joints bonds. This will include drilling of 7.0/7.1/7.2 mm dia holes in rails (4 Nos.) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own tools as per instruction of Rly. Engineer at site.
Digital Multimeter of Fluke 287 Industrial, True RMS with temperature, Analog bar graph, Digital display, Backlight, 1000V AC/DC, measure up to 10A, 20A for up to 30 seconds or Superior.
Fixing of Electrical Point Machine on the extended sleepers at points as per std. practice and as per RDSO Drg No. SA 91 51-52 or 9710 or 9161 as per section of rails used. Item includes fixing switch extension bracket, providing insulation for switch extension bracket, fixing ground connection, adjusting opening of the switches and adjusting the point machine with crank handle. The item also includes : (i) Complete material for installation like ground-connections, switch extension brackets, point insulation material, I pipes, wiring materials, various fixing nuts & bolts 20 including castle nuts, spring washers (ii) All smithy & fitting works required at site for complete installation. (iii) Installation of gauge tie plate & providing insulation for gauge tie plate (Insulation in William Stretcher Bar will be Provide by Railways). (iv) Wiring inside the point machine, insertion and termination of tail cable in point machine and junction boxes / location box /cable hut as per extent practice on WR and the instruction of Railway Engineer at site. (v) Supply and fixing of suitable size GI pipes with flange for taking cable into point machine. Note ; The ground connections shall be suitable to the Point Machines as specified by Engineer-in-charge and shall be suitable to the point lay out i.e. 60 Kg. / 52 Kg / 90R as per yard layout. Electrical Point Machine and M-6 / Screw less terminals will be supplied by Railways / covered in Schedule separately.
A2-Supply Items [RJT-Okha - CTR(P) - 4.190 TKM ,TRR(P) - 25.155 TKM]
Track Lead Junction Boxes as per C.Rly Drg. No. RST 11509 made from fiber glass along with terminal blocks.
Channel Pins MS (Galvanized) single groove, 7 mm suitable for 4mm dia bonding wire as per spec No IRS S 17 & RDSO Drg No. S-69/M.
GI wire 8 SWG (4mm dia) suitable for track circuit rail bonding.
Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & antioxidant and non flame propagating type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia. (The 4 manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified.
Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes.
Track feed battery chargers, 110V AC input, 2 to 6 V DC Output; as per Specn.No.IRS.S 89/ 2013 with latest amendments. Charger shall be suitable for charging 80 AH battery.
PVC jacketed wire rope for Track Lead connections. PVC jacketed wire ropeshould be 7 of Galvanized steel wire rope 6 mm dia (6x19 stranded wire with steel core of 6 mm dia) heathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1970. Reclaimed or recycled material hould not be used.
Point insulation Complete set as per RDSO Specification IRS: S-40/84 for L-Bracket, Switch bracket, Split-Stretcher bar & Gauge tie plates etc. (52Kg/60Kg as per site requirement)
Relay, AC Immune, plug-in-type, Style 'QTA2', DC Neutral track, 9 ohm DC 2F. 1B 9 contacts, front and back contacts metal to carbon, complete with plug board, retaining clip & connectors confirming to BRS:939A, BRS:966 (Appendix F2), IRS:S 34 & IRS:S 23 & 60 (as applicable). Per
Termination of outdoor cables, main cables laid in location boxes, Cable termination 10 rack etc at both ends on ARA terminal or on 8 way terminals or on screw less connectors. Both ends of a cable core terminated shall be counted as one terminal. This includes all associated works of pulling out the cable from underground, peeling off insulation, dressing of cable core supported on sting rod with contractor's own material. The work shall be done as per instructions of Rly engineer at site.
Excavation of cable trench as per cable route plan,1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtrs wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route 11 from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m.
Horizontal direction drilling/boring without damage of surface road using Auger Machine. The bore shall be 150 mm dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. 12 The length of the bore shall be minimum 4 Mtrs long. this include insertion of different dia DWC pipe/ GI pipes coupling etc. as per direction of Engineer In charge. Note:- Pipe will be supplied by railway. Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item 13 includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P.(Cables will be maggered before and after its laying by contractor under supervision of Railway Representative and he will submit the maggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.
Erection, Fitting and Rail connection of Track Lead Junction Box on two supports 14 (M.S.angle) with contractor's fixing material and PVC jacketed wire for track lead connection including angles of size 40 x 40 x 5 mm 1200 mm length. This will include drilling of holes for track lead/side connections on rail. The work shall be done as per Drg. No. S&T/Const./JHS/T 115 & instructions of Rly engineer at site. Running
Provision of bonding with GI wire 4mm dia ( 8 SWG) for track jumper & fish plate joints bonds. This will include drilling of 7.0/7.1/7.2 mm dia holes in rails (4 Nos.) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own tools as per instruction of Rly. Engineer at site.
Digital Multimeter of Fluke 287 Industrial, True RMS with temperature, Analog bar graph, Digital display, Backlight, 1000V AC/DC, measure up to 10A, 20A for up to 30 seconds or Superior.
A3-Supply Items [Jamnagar-Kanalus Section : CTR (P) from Kms.
Channel Pins MS (Galvanized) single groove, 7 mm suitable for 4mm dia bonding wire as per spec No IRS S 17 & RDSO Drg No. S-69/M.
ARA Terminal blocks with links made of PBT Spec No.IRS/75/2006(Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4.
Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes.
Track feed battery chargers, 110V AC input, 2 to 6 V DC Output; as per Specn.No.IRS.S 89/ 2013 with latest amendments. Charger shall be suitable for charging 80 AH battery.
PVC jacketed wire rope for Track Lead connections. PVC jacketed wire ropeshould be 5 of Galvanized steel wire rope 6 mm dia (6x19 stranded wire with steel core of 6 mm dia) heathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1970. Reclaimed or recycled material hould not be used.
Point insulation Complete set as per RDSO Specification IRS: S-40/84 for L-Bracket, Switch bracket, Split-Stretcher bar & Gauge tie plates etc. (52Kg/60Kg as per site requirement)
Earth Electrode as per Drg. No. CSTE / 6091
Switch Plate lubricant - Cenolube 100 or better NLGI 00 GRADE Black colored which should be non asphaltic Non bituminous blend of very heavy oils, inert thickeners and lubricating solids coupled with molybdenum disulfide and graphite with no traces of chlorinated solvent such as 1,1,1 trichloroethane which are flammable and harmful to the environment. Should have a blend of select high viscosity index solvent refined severely hydrofinished paraffin base oils and synthetic base fluids. It should incorporate solid lubricants & organo molybdenum disulphide to fill & lubricate micronized asperities to provide & form many films on the contact surfaces to prevent metal-to- metal contact. It shall be designed to be hand applied providing a tough adherent Lubricant film with 8 Tacky semi-dry finish reducing contaminant adhesion. The grease Should Not form a difficult to remove thick DRY film which requires scrapping & solvent cleaning of Switch Plate specially before reapplication The grease should Not need Cleaning or scrapping before Reapplication. The Grease should be formulated for tropical climates and should not contain pour point depressants and should Not be too thin. The grease shall be Resistant to water wash off & dilution, water insoluble, non-melt and chemically resistant to exposed environment. The grease shall be formulated with Extreme Pressure additives, rust and corrosion inhibitors, anti-wear additives to protect external surfaces against the harsh elements in severe climates, thus reducing rust binding and adhesive wear on switch plates Four Ball Weld LOAD (ASTMD2596) >600 Kg, Copper corrosion 24 hrs @ 100c (ASTM D 4048) 1a -2e packing Size 20 kg /25kg Drum.'(Inspection Agency-Consignee)
A4-Supply Items [VG-RJT, WKR-NLK & SUNR-BTD-CTR(P)-4.012 Tkm,
Track Lead Junction Boxes as per C.Rly Drg. No. RST 11509 made from fiber glass along with terminal blocks.
Channel Pins MS (Galvanized) single groove, 7 mm suitable for 4mm dia bonding wire as per spec No IRS S 17 & RDSO Drg No. S-69/M.
GI wire 8 SWG (4mm dia) suitable for track circuit rail bonding.
Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & antioxidant and non flame propagating type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and 4 shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified.
Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes.
Track feed battery chargers, 110V AC input, 2 to 6 V DC Output; as per Specn.No.IRS.S 89/ 2013 with latest amendments. Charger shall be suitable for charging 80 AH battery.
PVC jacketed wire rope for Track Lead connections. PVC jacketed wire ropeshould be 7 of Galvanized steel wire rope 6 mm dia (6x19 stranded wire with steel core of 6 mm dia) heathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1970. Reclaimed or recycled material hould not be used.
Point insulation Complete set as per RDSO Specification IRS: S-40/84 for L-Bracket, Switch bracket, Split-Stretcher bar & Gauge tie plates etc. (52Kg/60Kg as per site requirement)
Relay, AC Immune, plug-in-type, Style 'QTA2', DC Neutral track, 9 ohm DC 2F. 1B 9 contacts, front and back contacts metal to carbon, complete with plug board, retaining clip & connectors confirming to BRS:939A, BRS:966 (Appendix F2), IRS:S 34 & IRS:S 23 & 60 (as applicable). Per
Termination of outdoor cables, main cables laid in location boxes, Cable termination 10 rack etc at both ends on ARA terminal or on 8 way terminals or on screw less connectors. Both ends of a cable core terminated shall be counted as one terminal. This includes all associated works of pulling out the cable from underground, peeling off insulation, dressing of cable core supported on sting rod with contractor's own material. The work shall be done as per instructions of Rly engineer at site.
Excavation of cable trench as per cable route plan,1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtrs wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route 11 from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m.
Horizontal direction drilling/boring without damage of surface road using Auger Machine. The bore shall be 150 mm dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. 12 The length of the bore shall be minimum 4 Mtrs long. this include insertion of different dia DWC pipe/ GI pipes coupling etc. as per direction of Engineer In charge. Note:- Pipe will be supplied by railway. Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item 13 includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P.(Cables will be maggered before and after its laying by contractor under supervision of Railway Representative and he will submit the maggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.
Erection, Fitting and Rail connection of Track Lead Junction Box on two supports 14 (M.S.angle) with contractor's fixing material and PVC jacketed wire for track lead connection including angles of size 40 x 40 x 5 mm 1200 mm length. This will include drilling of holes for track lead/side connections on rail. The work shall be done as per Drg. No. S&T/Const./JHS/T 115 & instructions of Rly engineer at site. Running
Provision of bonding with GI wire 4mm dia ( 8 SWG) for track jumper & fish plate joints bonds. This will include drilling of 7.0/7.1/7.2 mm dia holes in rails (4 Nos.) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own tools as per instruction of Rly. Engineer at site.
Digital Multimeter of Fluke 287 Industrial, True RMS with temperature, Analog bar graph, Digital display, Backlight, 1000V AC/DC, measure up to 10A, 20A for up to 30 seconds or Superior.
A5-Supply Items ( Kanalus: Rectification of bad layout from Pt 112
Position Light Shunt Signal Unit Complete with Post (made of GI Pipe of 80 mm 1 Diameter Medium Class IS Spec. No. IS: 1239 Pt. 1/1990) Base, Hood, and Cover, etc. as per Drg. No. SA-23840, Signal Number Plate, suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item).
Point insulation Complete set as per RDSO Specification IRS: S-40/84 for Switch bracket, Split-Stretcher bar & Gauge tie plates (52 Kg/60Kg as per site requirement).
Supply of DC Track Circuit Accessories as follows :- Track feed battery chargers, 110V AC input, 2 to 6/10 V DC Output; as per Specn. No. IRS.S 89/ 2013 with latest amendments. Charger shall be suitable for charging 80 AH battery.
Supply of DC Track Circuit Accessories as follows :- Choke Coil for Single Rail Track Circuit on 25 KV 50 Hz AC Electrified Section as per Spec No IRS S 65/1983 with latest amendments.
Supply of DC Track Circuit Accessories as follows :- Low maintenance Lead acid secondary cell 2V/80 AH (Track feed Battery), shelf mounting type conforming to IRS:S- 88/2004 or latest (uncharged).
Supply of DC Track Circuit Accessories as follows :- Adjustable Track Feed Resistance disc type 30 ohms as per RDSO Drg. No. SA 20166/M (Adv.) with latest amendments (with Phenolic molded base).
Provision of Field accessories of DC Track Circuits GI wire 8 SWG (4mm Dia) suitable for track circuit rail bonding.
Provision of Field accessories of DC Track Circuits Channel Pins MS (Galvanized) single groove, 7 mm suitable for 4mm Dia bonding wire as per spec No IRS S 17 & RDSO Drg No. S- 69/M.
Supply, Installation, Testing and Commissioning of High Availability Single section digital axle counters with Dual sensor system as per RDSO/SPN/177/2012 version 3or latest. This includes The supply of High frequency web mounting type Tx coil/Rx coil, VR/PR Box duly wired, Vital 9 relays, PR Relays, Clamp with deflector plates & hardware, Dual display reset box with auto resetting facility, Surge voltage protection devices and filter card to be mounted on din rail etc. as per OEM for complete installation & testing& commissioning of(HASSDAC) system NOTE: One set of HASSDAC system will include equipment required to monitor One Up line or One Den line of a full Block Section between two stations. Note: - "Supply of HASSDAC as per RDSO specification along with outdoor industrial grade enclosure (Approved by Railways) similar to Rattle/Pyrotech make.
Miniature, Plug-in Type, DC Neutral Line, Non AC Immunized Relay, Style QN1, 24 V DC, 8F-8B/12F-4BContact, Code ABCDF/ABCDE Spec: BRS: 930; IRS S 34; IRS S 23.
Miniature, Plug-in Type, DC Neutral Line AC Immunized Relay, Style QNA1, 24 V DC, 8F-8B/12F-4BContact, Code ABDGH/ABDFH Spec: BRS: 931A; IRS S 34; IRS S 23; IRS S 60-78.
Universal AC ECR of Q series, type "QECX61" suitable for AC LED all signal aspect, Front & back contact Metal to Carbon type complete with plug board retaining clip & connectors conforming to Spec STS/E/Relays/AC Lit LED Signal/09/2002, BRS: 941A, IRS: S34 and IRS: S23 (as applicable).
Miniature, Plug-in Type, DC Neutral Line Magnetically Latched Relay, Style QL1, 24 V DC, 11F-4B Contact, Code ABDEG Spec: BRS:935A ; IRSS 34 ; IRS S 23.
Plug in Type, Tractive Armature, AC Immunized, DC Biased Contactor Relay, Style QBCA1,2HF-4B Contact,24 V DC, Code BCEJK Spec:BRS:943 ; IRS S 34 ; IRS S 23 ;IRSS 60-78.
Miniature, Plug in Type, M to C,DC Neutral ,Track relay, ACI, Style QTA2, 9 Ohm, 2F- 1B contact, Code - FGHKX Spec : BRS :939-A & 966 (Appx-F2) & IRS : S-23, S-23,S-34 & 60.
Supply of self supported aluminum flat step ladder (conforming to ISI) 5 ft. height. Ladder should be self-supported and it should be made up of rust proof Aluminum of Min 16 SWG. No plastic hinges/Step support should be used.
Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. 17 RDSO/SPN/189/2004. With the latest amendments Disconnect Terminal Block, Screw less type, 4- wire front entry (Two in-put & Two out-put) The color will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3). as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments. Note: Make to be approved by Railway before supply.
Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With the latest amendments Supply of End plate 2.5mm/0.091 in thick as per site requirement.
Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With the latest amendments Supply of End Stopper 10mm/0.0394 in width as per site requirement.
Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With the latest amendments Supply of Carrier Rails for above 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement.
Desk type Electronic Magneto Telephone as per spec No IRS/TC-79/2000 or with latest amendments.
Earth Electrode as per Drg. No. CSTE / 6091.
Supply of Fiber/ SMC/FRP/RCC Earth Chamber.
ARA Terminal blocks with links made of PBT Spec No.s/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4.
SS Location box made of Spl Grade SS 304 of size as per Drg. No. DRM/SG/945 dtd 03.03.2011 (Half app. Case) or latest. Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply.
SS Location box made of Spl Grade SS 304 of size as per Drg. No. DRM/SG/948 dt. 26.04.2011 (Single app. Case) or latest. Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply.
IS 13410: Glass Reinforced Polyester Sheet Moulding Compounds (SMC) Size of Sheet : 1000x1000x8
Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3) or latest.
Flexible cable (Power wire), multi-strand copper conductors cross section 1x6 Sq.mm. ( 85 conductor each diameter 0.30 +/- 0.01) as per IS 694/1990 with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS(S)76/89 or latest. Running
Medium Class G.I. Pipes to IS: 1239 (Pt.)-2004 or latest; 100mm dia. (int. Dia) 3.65 mm thick or above with coupling. G.I. pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. pipes.
B1-NS Items [Supply & Execution - TTR (TWS+WCMSC) 21 sets]
Supply of Drill bits 7.2 mm as per instruction of Engineer-in-charge.
Mini AC/DC Low Current Clamp Meter as per Specn. High Sensitivity, Miniature type Clamp, Resolution of 0.1 mA for AC,1 mA for DC Current, Measurement range 0- 20 A, Make KEW, Fluke OR SIMILAR.
Drilling of holes of different sizes in rails 7.2mm/ 12 mm/16mm/22mm
Maintenence of Signalling gears required for execution of BCM/TTM/FRM work includes 1. Proper dressing of track lead jumpers as required by railway reprsentative at site before and after connecting of BCM/TTM/FRM machines. This includes replacement of defective jumpers. Jumpers will be provided by railway and / or 2.- Fixing, installation and testing of rodding sets for 4 point machines/EPD and FPL of point including all associated geras of mech. points as per direction of railway representative at site, and / or 3. All damaged cables due to BCM/TTM/FRM work should be meggeres properly and if required should be replaced by contractor as directed by railway representative at site. Cable will be supplied by railways. The team to be provided for this work should comprise of Black Smith-1 no., Fitter-1 no and Hepler -2 nos. also it include any work of EOLB or sliding boom and earthing arrangement of Signalling gears, Any other work as per instruction of Railway Engineer. All T &P & jigs required to execute the work will be supplied by contractor.
Supply and placing of Half Round RCC pipes & collars of 150 mm internal dia, 2 meter long (or two pieces of 1 meter long) along with collars as per IS No. 458/2003 of NP type
Shifting of Exposed cables. The item includes Removal of exposed cable from existing trench & laying the same in new trenches. Digging, Placing of capping/Half round RCC pipe covered separately
Removal & reinstallation of Axle Counter/Tx-Rx coil/TLJB (each set consists of web mounting type TX & RX Coils). This will be executed as per instruction of site supervisor.
Switch Plate lubricant - Cenolube 100 or better NLGI 00 GRADE Black colored which should be non asphaltic Non bituminous blend of very heavy oils, inert thickeners and lubricating solids coupled with molybdenum disulfide and graphite with no traces of chlorinated solvent such as 1,1,1 trichloroethane which are flammable and harmful to the environment. Should have a blend of select high viscosity index solvent refined severely hydrofinished paraffin base oils and synthetic base fluids. It should incorporate solid lubricants & organo molybdenum disulphide to fill & lubricate micronized asperities to provide & form many films on the contact surfaces to prevent metal-to- metal contact. It shall be designed to be hand applied providing a tough adherent Lubricant film with 8 Tacky semi-dry finish reducing contaminant adhesion. The grease Should Not form a difficult to remove thick DRY film which requires scrapping & solvent cleaning of Switch Plate specially before reapplication The grease should Not need Cleaning or scrapping before Reapplication. The Grease should be formulated for tropical climates and should not contain pour point depressants and should Not be too thin. The grease shall be Resistant to water wash off & dilution, water insoluble, non-melt and chemically resistant to exposed environment. The grease shall be formulated with Extreme Pressure additives, rust and corrosion inhibitors, anti-wear additives to protect external surfaces against the harsh elements in severe climates, thus reducing rust binding and adhesive wear on switch plates Four Ball Weld LOAD (ASTMD2596) >600 Kg, Copper corrosion 24 hrs @ 100c (ASTM D 4048) 1a -2e packing Size 20 kg /25kg Drum.'(Inspection Agency-Consignee)
Installation of cenolube 100 Grease. Afetr cleaning of old oil and greece and re- lubrication of switch chair plate at point machine at interval of 15 days per point machine. Tightening of nuts check nuts and bolts lock nuts holding the detector slides lock slides with lugs. Workers are required to check for the tightness of the switch plates and points and clean the rust and dust apply Cenolube 100 grease on slide chaires & assembly up to 3 sleepers from the toe of switch. Rate per person for 3 persons to be deployed for 60 days time. (Inspection Agency- Consignee)
Supply of pin branzing materals for rail head connectivity bond. Each set consisting of 10 a) galvanised steel wire in rope lay constitutions 20 sq mm X 145 mm long including Cu legs on both end (SAFE 3070) 1no. b)Brazing Pins (SAFE 10011) 2 nos., c) Ferrules (SAFE 2003) 2nos., Note As per IRS: S-103-2004. (Insp. RITES). (Make: safetrack sweden or similar)
Supply of pin branzing materals for 2.5 Mtr TLJB bond. Each set consisting of a) 11 galvanised steel wire in rope lay consititution 2.5 mts. long including Cu legs on both end (SAFE 3070) 1no. b)Brazing Pins (SAFE 10011) 2 nos., c) Ferrules (SAFE 2003) 2nos., Note As per IRS: S- 103-2004. (Insp. RITES). (Make: safetrack sweden or similar)
Supply of pin branzing materals for 4.5 Mtr TLJB bond. Each set consisting of a) 12 galvanised steel wire in rope lay consititution 4.5 mts. long including Cu legs on both end (SAFE 3070) 1no. b)Brazing Pins (SAFE 10011) 2 nos., c) Ferrules (SAFE 2003) 2nos., Note As per IRS: S- 103-2004. (Insp. RITES). (Make :safetrack sweden or similar)
Installation charge per bond of continuity bond, jumper bonds, earthing bonds by the technician & pin brazing equipment .(For above item no.11,12 &13)
B2-NS Items [Supply & Execution Items - RJT-Okha - CTR(P) -
Supply of Drill bits 7.2 mm as per instruction of Engineer-in-charge.
Mini AC/DC Low Current Clamp Meter as per Specn. High Sensitivity, Miniature type Clamp, Resolution of 0.1 mA for AC,1 mA for DC Current, Measurement range 0- 20 A, Make KEW, Fluke OR SIMILAR.
Drilling of holes of different sizes in rails 7.2mm/ 12 mm/16mm/22mm
Maintenence of Signalling gears required for execution of BCM/TTM/FRM work includes 1. Proper dressing of track lead jumpers as required by railway reprsentative at site before and after connecting of BCM/TTM/FRM machines. This includes replacement of defective jumpers. Jumpers will be provided by railway and / or 2.- Fixing, installation and testing of rodding sets for 4 point machines/EPD and FPL of point including all associated geras of mech. points as per direction of railway representative at site, and / or 3. All damaged cables due to BCM/TTM/FRM work should be meggeres properly and if required should be replaced by contractor as directed by railway representative at site. Cable will be supplied by railways. The team to be provided for this work should comprise of Black Smith-1 no., Fitter-1 no and Hepler -2 nos. also it include any work of EOLB or sliding boom and earthing arrangement of Signalling gears, Any other work as per instruction of Railway Engineer. All T &P & jigs required to execute the work will be supplied by contractor.
Supply and placing of Half Round RCC pipes & collars of 150 mm internal dia, 2 meter long (or two pieces of 1 meter long) along with collars as per IS No. 458/2003 of NP type
Shifting of Exposed cables. The item includes Removal of exposed cable from existing trench & laying the same in new trenches. Digging, Placing of capping/Half round RCC pipe covered separately
Removal & reinstallation of Axle Counter/Tx-Rx coil/TLJB (each set consists of web mounting type TX & RX Coils). This will be executed as per instruction of site supervisor.
Switch Plate lubricant - Cenolube 100 or better NLGI 00 GRADE Black colored which should be non asphaltic Non bituminous blend of very heavy oils, inert thickeners and lubricating solids coupled with molybdenum disulfide and graphite with no traces of chlorinated solvent such as 1,1,1 trichloroethane which are flammable and harmful to the environment. Should have a blend of select high viscosity index solvent refined severely hydrofinished paraffin base oils and synthetic base fluids. It should incorporate solid lubricants & organo molybdenum disulphide to fill & lubricate 8 micronized asperities to provide & form many films on the contact surfaces to prevent metal-to- metal contact. It shall be designed to be hand applied providing a tough adherent Lubricant film with Tacky semi-dry finish reducing contaminant adhesion. The grease Should Not form a difficult to remove thick DRY film which requires scrapping & solvent cleaning of Switch Plate specially before reapplication The grease should Not need Cleaning or scrapping before Reapplication. The Grease should be formulated for tropical climates and should not contain pour point depressants and should Not be too thin. The grease shall be Resistant to water wash off & dilution, water insoluble, non-melt and chemically resistant to exposed environment. The grease shall be formulated with Extreme Pressure additives, rust and corrosion inhibitors, anti-wear additives to protect external surfaces against the harsh elements in severe climates, thus reducing rust binding and adhesive wear on switch plates Four Ball Weld LOAD (ASTMD2596) >600 Kg, Copper corrosion 24 hrs @ 100c (ASTM D 4048) 1a -2e packing Size 20 kg /25kg Drum.'(Inspection Agency-Consignee)
Installation of cenolube 100 Grease. Afetr cleaning of old oil and greece and re- lubrication of switch chair plate at point machine at interval of 15 days per point machine. 9 Tightening of nuts check nuts and bolts lock nuts holding the detector slides lock slides with lugs. Workers are required to check for the tightness of the switch plates and points and clean the rust and dust apply Cenolube 100 grease on slide chaires & assembly up to 3 sleepers from the toe of switch. Rate per person for 3 persons to be deployed for 60 days time. (Inspection Agency- Consignee)
B3-Execution ITems [Jamnagar-Kanalus Section : CTR (P) from Kms.
Drilling of holes of different sizes in rails 7.2mm/ 12 mm/16mm/22mm
As and when required by the Engineer in charge arranging/providing of labours for various safety related works such as protection of track etc. with contractors T&P, equipment etc.Scope of work as furnished in the tender and directed by the Engineer in charge. Per
Termination of outdoor cables, main cables laid in location boxes, Cable termination 3 rack etc at both ends on ARA terminal or on 8 way terminals or on screw less connectors. Both ends of a cable core terminated shall be counted as one terminal. This includes all associated works of pulling out the cable from underground, peeling off insulation, dressing of cable core supported on sting rod with contractor's own material. The work shall be done as per instructions of Rly engineer at site.
Excavation of cable trench as per cable route plan,1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtrs wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route 4 from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m.
Digging of cable trench 0.3 Mtrs. Deep and 0.3 Mtrs. Wide on Asphalted Platform / Road / Hard rocky area. Refilling with earth leveling of trenches & restoring the original surface of trenches.
Cutting of Hard rock in trenches /Preparation of cable way/Chase 150mm wide at the bottom and 300mm deep in hard rock ( Drg prepared by contactor & approved by Engineer In charge)for laying of S&T cables where minimum required depth not possible & which is verified and 6 agreed by Engineer In charge of the work or his reprenstative shall be made as per Drg. No RE/S&T/ALD/SK/301/85. refilling of the same with concrete mixture of 1:3:6 from top of the cable way/ chase. Payment of concrete will be made separately through a seperate item in the schedule of work.
"Horizontal direction drilling/boring without damage of surface road using Auger Machine. The bore shall be 150 mm dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. 7 The length of the bore shall be minimum 4 Mtrs long. this include insertion of different dia DWC pipe/ GI pipes coupling etc. as per direction of Engineer In charge. Note:- Pipe will be supplied by railway. Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. "
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item 8 includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P.(Cables will be maggered before and after its laying by contractor under supervision of Railway Representative and he will submit the maggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.
Supply and placing of Half Round RCC pipes & collars of 150 mm internal dia, 2 meter long (or two pieces of 1 meter long) along with collars as per IS No. 458/2003 of NP type
Supply and installation of RCC cable route marker engraved and painted on both side along the route every 50mm and route diversion as per Drg. No 4014/00/CC4 or latest/ Stone marker.
Cement concrete work for miscellaneous items in the ratio 1 : 3 : 6 . Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor).
Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 12 cement and sand mixture both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks sand and cement to be supplied by the contractor.
Erection, Fitting and Rail connection of Track Lead Junction Box on two supports 13 (M.S.angle) with contractor's fixing material and PVC jacketed wire for track lead connection including angles of size 40 x 40 x 5 mm 1200 mm length. This will include drilling of holes for track lead/side connections on rail. The work shall be done as per Drg. No. S&T/Const./JHS/T 115 & instructions of Rly engineer at site. Running
Provision of bonding with GI wire 4mm dia ( 8 SWG) for track jumper & fish plate joints bonds. This will include drilling of 7.0/7.1/7.2 mm dia holes in rails (4 Nos.) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own tools as per instruction of Rly. Engineer at site.
Shifting of Exposed cables. The item includes Removal of exposed cable from existing trench & laying the same in new trenches. Digging, Placing of capping/Half round RCC pipe covered separately
Installation of earth electrode as per std. practice and connecting it to equipments to be earthed. This item includes digging of pit in earth 3 m deep & fixing earth electrode pipe, casting 16 of cement concrete enclosure & cover as per Drg No. S&T/Tender/27.Soil treatment to be done as per std. practice. This item includes provision of MS flat/earth lead wires as per instruction and soldering of lead wires. The other end of the wire is to be connected to block equipment, power equipment, cable sheath, signals etc. as per site requirements. 7strand GI wire shall be used as earth lead wire. (Supply of earth electrode is covered in Sch. 'A').
Fixing of ARA Terminals /Screw less connectors and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry.
Fixing of GI pipes for crossing the culverts, bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site.
Refixing of electrical point machine, ground connection during phase working (Non 19 interlocked working) after removing the existing fitting if any, adjustment if necessary, cable termination, wiring , testing and commissioning of electrically operated point, fixing and connecting point indicator on derail switch if necessary. The work shall be done as per extant practice on WR & the instruction of Railway Engineer at site
Removal & reinstallation of Axle Counter/Tx-Rx coil/TLJB (each set consists of web mounting type TX & RX Coils). This will be executed as per instruction of site supervisor
Installation of cenolube 100 Grease. Afetr cleaning of old oil and greece and re- lubrication of switch chair plate at point machine at interval of 15 days per point machine. 21 Tightening of nuts check nuts and bolts lock nuts holding the detector slides lock slides with lugs. Workers are required to check for the tightness of the switch plates and points and clean the rust and dust apply Cenolube 100 grease on slide chaires & assembly up to 3 sleepers from the toe of switch. Rate per person for 3 persons to be deployed for 60 days time. (Inspection Agency- Consignee)
Fixing of Electrical Point Machine on the extended sleepers at points as per std. practice and as per RDSO Drg No. SA 91 51-52 or 9710 or 9161 as per section of rails used. Item includes fixing switch extension bracket, providing insulation for switch extension bracket, fixing ground connection, adjusting opening of the switches and adjusting the point machine with crank handle. The item also includes : (i) Complete material for installation like ground-connections, switch extension brackets, point insulation material, I pipes, wiring materials, various fixing nuts & bolts 22 including castle nuts, spring washers (ii) All smithy & fitting works required at site for complete installation. (iii) Installation of gauge tie plate & providing insulation for gauge tie plate (Insulation in William Stretcher Bar will be Provide by Railways). (iv) Wiring inside the point machine, insertion and termination of tail cable in point machine and junction boxes / location box /cable hut as per extent practice on WR and the instruction of Railway Engineer at site. (v) Supply and fixing of suitable size GI pipes with flange for taking cable into point machine. Note ; The ground connections shall be suitable to the Point Machines as specified by Engineer-in-charge and shall be suitable to the point lay out i.e. 60 Kg. / 52 Kg / 90R as per yard layout. Electrical Point Machine and M-6 / Screw less terminals will be supplied by Railways / covered in Schedule separately.
B4-NS Items {Supply & Execution items-[VG-RJT, WKR-NLK & SUNR-BTD-
Supply of Drill bits 7.2 mm as per instruction of Engineer-in-charge.
Mini AC/DC Low Current Clamp Meter as per Specn. High Sensitivity, Miniature type Clamp, Resolution of 0.1 mA for AC,1 mA for DC Current, Measurement range 0- 20 A, Make KEW, Fluke OR SIMILAR.
Drilling of holes of different sizes in rails 7.2mm/ 12 mm/16mm/22mm
Maintenence of Signalling gears required for execution of BCM/TTM/FRM work includes 1. Proper dressing of track lead jumpers as required by railway reprsentative at site before and after connecting of BCM/TTM/FRM machines. This includes replacement of defective jumpers. Jumpers will be provided by railway and / or 2.- Fixing, installation and testing of rodding sets for 4 point machines/EPD and FPL of point including all associated geras of mech. points as per direction of railway representative at site, and / or 3. All damaged cables due to BCM/TTM/FRM work should be meggeres properly and if required should be replaced by contractor as directed by railway representative at site. Cable will be supplied by railways. The team to be provided for this work should comprise of Black Smith-1 no., Fitter-1 no and Hepler -2 nos. also it include any work of EOLB or sliding boom and earthing arrangement of Signalling gears, Any other work as per instruction of Railway Engineer. All T &P & jigs required to execute the work will be supplied by contractor.
Supply and placing of Half Round RCC pipes & collars of 150 mm internal dia, 2 meter long (or two pieces of 1 meter long) along with collars as per IS No. 458/2003 of NP type
Shifting of Exposed cables. The item includes Removal of exposed cable from 6 existing trench & laying the same in new trenches. Digging, Placing of capping/Half round RCC pipe covered separately
Removal & reinstallation of Axle Counter/Tx-Rx coil/TLJB (each set consists of web mounting type TX & RX Coils). This will be executed as per instruction of site supervisor.
Switch Plate lubricant - Cenolube 100 or better NLGI 00 GRADE Black colored which should be non asphaltic Non bituminous blend of very heavy oils, inert thickeners and lubricating solids coupled with molybdenum disulfide and graphite with no traces of chlorinated solvent such as 1,1,1 trichloroethane which are flammable and harmful to the environment. Should have a blend of select high viscosity index solvent refined severely hydrofinished paraffin base oils and synthetic base fluids. It should incorporate solid lubricants & organo molybdenum disulphide to fill & lubricate micronized asperities to provide & form many films on the contact surfaces to prevent metal-to- metal contact. It shall be designed to be hand applied providing a tough adherent Lubricant film with 8 Tacky semi-dry finish reducing contaminant adhesion. The grease Should Not form a difficult to remove thick DRY film which requires scrapping & solvent cleaning of Switch Plate specially before reapplication The grease should Not need Cleaning or scrapping before Reapplication. The Grease should be formulated for tropical climates and should not contain pour point depressants and should Not be too thin. The grease shall be Resistant to water wash off & dilution, water insoluble, non-melt and chemically resistant to exposed environment. The grease shall be formulated with Extreme Pressure additives, rust and corrosion inhibitors, anti-wear additives to protect external surfaces against the harsh elements in severe climates, thus reducing rust binding and adhesive wear on switch plates Four Ball Weld LOAD (ASTMD2596) >600 Kg, Copper corrosion 24 hrs @ 100c (ASTM D 4048) 1a -2e packing Size 20 kg /25kg Drum.'(Inspection Agency-Consignee)
Installation of cenolube 100 Grease. Afetr cleaning of old oil and greece and re- lubrication of switch chair plate at point machine at interval of 15 days per point machine. 9 Tightening of nuts check nuts and bolts lock nuts holding the detector slides lock slides with lugs. Workers are required to check for the tightness of the switch plates and points and clean the rust and dust apply Cenolube 100 grease on slide chaires & assembly up to 3 sleepers from the toe of switch. Rate per person for 3 persons to be deployed for 60 days time. (Inspection Agency- Consignee)
B5-Execution Items ( Kanalus: Rectification of bad layout from Pt 112
Foundation, Erection & Installation of Shunt Signal. Excavation and Casting of 1 foundation for Shunt Signal as per Drg. No. CSTE/6090 with Contractor's own materials including Cement and Anchor Bolts of Standard Size. The required scaffolding, Ferma etc. for Casting of foundation will have to be brought by the Contractor at his own cost.
Foundation, Erection & Installation of Shunt Signal. Erection of Position Light Shunt signal with Base, Post, and Signal unit. Wiring & Fixing of Number Plate .The work shall be done as per instructions of Rly engineer at site.
Fabrication and fixing of 'A' Marker (Drg No. CSTE/6180), 'AG' Marker (Drg No. 3 CSTE/6181), 'P' Marker (Drg No. CSTE/6182), Arrow Marker (Drg No. CSTE/6183), 'G' Marker (Drg No. CSTE/6184), 'C' Marker (Drg No. CSTE/6185). Marker disk on signals as per standard practice All material required for this work shall be supplied by Contractor.
Fixing of Electrical Point Machine on the extended sleepers at points as per std. practice and as per RDSO Drg No. SA 91 51-52 or 9710 or 9161 as per section of rails used. Item includes fixing switch extension bracket, providing insulation for switch extension bracket, fixing ground connection, adjusting opening of the switches and adjusting the point machine with crank handle. The item also includes : (i) Complete material for installation like ground-connections, switch extension brackets, point insulation material, I pipes, wiring materials, various fixing nuts & bolts 4 including castle nuts, spring washers (ii) All smithy & fitting works required at site for complete installation. (iii) Installation of gauge tie plate & providing insulation for gauge tie plate (Insulation in William Stretcher Bar will be Provide by Railways). (iv) Wiring inside the point machine, insertion and termination of tail cable in point machine and junction boxes / location box /cable hut as per extent practice on WR and the instruction of Railway Engineer at site. (v) Supply and fixing of suitable size GI pipes with flange for taking cable into point machine. Note ; The ground connections shall be suitable to the Point Machines as specified by Engineer-in-charge and shall be suitable to the point lay out i.e. 60 Kg. / 52 Kg / 90R as per yard layout. Electrical Point Machine and M-6 / Screw less terminals will be supplied by Railways / covered in Schedule separately. Per Track
Fixing and wiring of DC track circuit equipments i.e. track feed charger, resistance, track relay, battery, PPTC fuses etc., in the Apparatus Case and battery box as per standard 5 practice. Termination of tail cable on M 6 / Screw less terminals WAGO or FINOLEX or similar approved make terminals/ fuse blocks / HRC fuse. Item includes testing /commissioning of track circuit. Complete wiring material (including PPTC fuses) which are not covered in Schedule will be supplied by contractor. (Supply of Track feed battery charger, track feed battery, resistances & 'B' type choke & Track relays will be supplied by Railways / covered in Schedule separately).
Installation of DC track circuits covering points zones also. The item includes provision of continuity bonds of seven strand PVC jacketed wire/ GI wire 8 SWG on rail joints after drilling bond-hole of 7.0/7.1/7.2mm Dia (double bond with sleeves and rail clips are to be provided at each rail joint), insertion of insulated block joint, fixing of Track lead Junction box on MS angle two numbers of size 40X40X5 mm 1200 mm length for track feed/ jumper / track relay ends of track 6 CCTs (as per double TLJB arrangements) and also for fixing jumper cables as per insulation diagram WR Drg No. CSTE/6055 and standard practice, making rail connections through suitable insulated sleeves from Track lead Junction box at TF, jumper & TR end with seven strand PVC jacketed wire /GI wire 8 SWG, rail clips for fixing bond wire on the TLJB as per standard practice, termination of tail cables on bootleg terminals etc. TF/TR wiring shall be fixed on the suitable arrangement on PRC sleepers with the help of hooks. Hooks shall be provided on PRC sleepers with the help of suitable steel bracket. This item also includes fixing & supply of channel pins etc. The item also includes supply of MS angles/ trestles, GI wire 8 SWG / seven strand PVC jacketed wire, hooks, rail clips etc.
Installation, wiring & testing / commissioning of Axle Counter's Reset Box of all types 7 in Cabin/Panel room and wiring the same to integrate with the Axle counter as per the instructions of Railway Engineer at site. This includes laying & termination of cable if any form Panel Room/Axle Counter room /Relay room to Reset Box in DWC pipe / existing ladder.(When reset box is shifted from existing building to new building ).
Fixing & wiring of QNA1 / QNA1K relays for GPR Circuit in apparatus case as per Standard practice. Fixing and wiring material shall be supplied by the contactor.
Installation of Earth Electrode including MS flat for clamp etc. and connection to signalling equipments, lever frames, apparatus cases, signal, relay rack, block instrument, etc. as per technical specification given. This item includes digging of pit in earth 3 M deep & fixing earth 9 electrode pipe, casting of cement concrete enclosure & cover as per RDSO/SPN/ 197/2016.Soiltreatment to be done as per std. practice. This item includes provision of MS Flat, Earth lead wires and Soldering of lead wires. The other end of the wire is to be connected to block equipment, power equipment, cable sheath, and signals etc. as per site requirements. 7strand GI wire shall be used as earth lead wire. Supply of earth electrode is covered in other Item').
Fixing of ARA Terminals /Screw less connectors and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry.
Termination of outdoor cables, main cables laid in location boxes, Cable termination rack etc. at both ends on ARA terminal or on 8 way terminals or on screw less connectors. Both ends 11 of a cable core terminated shall be counted as one terminal. This includes all associated works of pulling out the cable from underground, peeling off insulation, dressing of cable core supported on sting rod with contractor's own material. The work shall be done as per instructions of Rly engineer at site.
Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 12 cement and sand mixture both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks sand and cement to be supplied by the contractor.
Cement concrete work for miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor).
Earthwork in filling in embankment, guide bunds, around buried type abutments, bridge gaps, trolley refuges, rain bunds if provided, platforms etc. with earth excavated from outside railway boundary entirely arranged by the contractor at his own cost as per RDSO's latest guidelines and specifications and special condition of contract including all leads, royalty, lifts, ascents, descents, crossing of nallahs or any other obstructions. The rates shall include all dressing of bank to final profile, demarcation and setting out of profile, site clearance, removing of shrubs, roots of vegetation growth, heavy grass, benching of existing slope of old bank, all handling/re-handling. Taxes, Octroi and royalty etc. as a complete job. Cut trees shall be property of railways and to be deposited in the railway godown unless specified otherwise in the Special conditions of contract.
Dismantling / Releasing of existing Signaling Gears. One Signalling gear will be all parts of one signal (consisting of CLS unit, Signal post along with base) or lever frame (5 levers set), 15 or one point (consisting of all parts of a mechanical point, point machine, ground connections etc.) or one track circuits (consisting of battery box & other parts of DC Track circuit / AFTC /DAC) or one Block instruments or One Lifting Barrier or One Location Box etc. .This includes the cost of transportation of release materials to store depot or as decided by consignee in charge. This work to be done by contactors with his own vehicle and labour. (Per unit means Per Gear).
Dismantling of Concrete foundation/ Demolishing RCC/CC/Stone work /Cutting Tar/ 16 carpentering/ CC Flooring / Precast concrete slab/ Brick work including leading the debris inside Railway limit or outside Railway limit as directed by site in charge. This work to be done by contactors with his own vehicle and labour.
Excavation and Casting of Apparatus Case foundation with contractor's own materials 17 including cement and anchor bolts of standard size. The required scaffolding Ferma etc. for Casting of foundation will have to be brought by the contractor at his own cost Single Case as per Drg No SK 748 or CSTE/5074 or SS Location
Excavation and Casting of Apparatus Case foundation with contractor's own materials 18 including cement and anchor bolts of standard size. The required scaffolding Ferma etc. for Casting of foundation will have to be brought by the contractor at his own cost Half Case as per Drg No SK 747or CSTE/5074 or SS Location.
Installation of Apparatus Cases with miniature 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. 'E' Type lock will be provided by Railway. Single Case
Installation of Apparatus Cases with miniature 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. 'E' Type lock will be provided by Railway. Half Case
Fabrication and fixing of SMC sheet in location box by providing all fixtures as per 21 Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per Drg and arrangement similar to SK 783- 1/2. With latest alterations & as per instructions of Rly engineer at site. Note: SMC sheet will be taken in place of phenolic laminated sheet. Single Case
Fabrication and fixing of SMC sheet in location box by providing all fixtures as per 22 Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per Drg and arrangement similar to SK 783- 1/2. With latest alterations & as per instructions of Rly engineer at site. Note: SMC sheet will be taken in place of phenolic laminated sheet. Half Case
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. This includes supply of paints of Asian Paints/ Nerolac / Dulux / Berger make. Full Case.
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. This includes supply of paints of Asian Paints/ Nerolac / Dulux / Berger make. Half Case.
Excavation of cable trench as per cable route plan, 1 Mtr. deep and of 0.3 Mtr. to 0.6 25 Mtr wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc., covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m.
Horizontal direction drilling/boring without damage of surface road using Auger Machine. The bore shall be 150 mm Dia & shall be done at the depth of minimum 1200 mm from the 26 ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtr long. The HDD with or without HDPE pipe as per direction of Engineer In charge. Note: HDPE pipe supply is taken as separate item. This item also includes cable laying (HDD boring). Running
Placing of DWC/RCC pipes along with collars in trenches at places of track and road crossings, platform cuttings etc. also for straight cable laying. (Cable laying is covered separately.) Running
Laying and fixing of Medium class GI pipes 100 mm Dia (4.5 mm thickness) as per IS 1239 ( Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or 28 less with 10 mm Dia hole, or at any other locations as decided by Site Engineer. The GI pipe is to be filled with chattered compound. It includes supply of all material required for fi Xing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. The e laying and fi Xing to be done as per RDSO drawings No. SDO/cable laying/011 and SDO/cable laying/012, issued vide RDSO document No. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014, or latest. Running
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trucking. This also includes laying of cables in track crossings & road crossings. Item 29 includes provision of labels of colored plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P.(Cables will be daggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.
Supply and installation of RCC cable route marker engraved and painted on both side along the route every 50mm and route diversion as per Drg. No 4014/00/CC4 or latest/ Stone marker.
C1-NS items- Supply & Execution (Kanalus: Rectification of bad layout
Supply of ferrules of different colour, printing termination details/ functions in different colours as per Railway specification and installation in location box CTR and power board etc. All the materials required for the work shall be supplied by the contractor
Fabrication and supply of premium quality ACP sheet 5 mm thickness with eco vinyl printing of approximately size 12inch x 18inch. This item includes lettering / numbering of 2 termination particulars of gears etc. This item also includes all material and resources required for fixing and transportation at station & LC gates. Colour coding of termination details will be as per WR /HQ policy letter. Termination details of location box will be given by Railway. Work will be carried out as per Western Railway practice One sample to be provided before printing to division office for examine/checking/approval.
Supply and placing of Half Round RCC pipes & collars of 150 mm internal dia, 2 meter long (or two pieces of 1 meter long) along with collars as per IS No. 458/2003 of NP type
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
DRM-RJT-26-27-SnT-E-10-GCC2022uptoACS11.pdf
ATTACHMENT
SpecialconditionofcontractCTRTTRwork.pdf
ATTACHMENT
ACSUPTO11_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid