| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.7 LAccepted-AOC | ₹21.7 L Quoted ₹22.0 L | L1 | Accepted-AOC ACCEPTED BEING LOWEST QUOTED |
| 2 | L2₹23.6 L+₹1.7 L (7.54%)Rejected-AOC | ₹23.6 L+₹1.7 L (7.54%) | L2 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
| 3 | L3₹24.9 L+₹2.9 L (13.4%)Rejected-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | ₹24.9 L+₹2.9 L (13.4%) | L3 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
Tender Value
Refer Docs
EMD Value
₹44,000
Closing Date
12 Sept 2024, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE ARMY GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
REPAIR AND CLEANING OF SEWAGE LINE AND OVERHEAD TANKS AT MIL STN GANDHINAGAR
2024_MES_665591_1
GE(A)/GNR/TOKEN/45 of 2024-25
Open Tender
Civil Works
Item Rate
240 days
MIL STN GANDHINAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE ARMY GANDHINAGAR
₹44,000
Yes
1 Jan 2025
12 Jul 2024
19 Sept 2024
12 Jul 2024
12 Sept 2024
26 Jul 2024
12 Jul 2024 - 24 Jul 2024
Amount
Cleaning of Sewage line upto 100mm bore from gully traps, grease traps, Manholes etc. upto 1.5 m deep by removing all filtn/silt, foreign materials and other deposits whatsoever completely and making the line free from all obstacles and testing the flow of sewer line evenly, smoothly by filling water. The cleaning operation will be carried out in suitable lengths by blocking the first and last manholes of sewage line and removing the silt/sludge & other deposits out side of MD land in covered van/trolley, all as specified & directed.
All as per description of serial item No. 1.00 here-in-before but sewage line upto 150 mm bore and depth of sewage line upto 2m.
All as per description of serial item No. 1.00 here-in-before but sewage line upto 200 mm bore and depth of sewage line upto 3m
All as per description of serial item No. 1.00 here-in-before but sewage line upto 300 mm bore and depth of sewage line upto 4.5m
Cleaning of septic tank of any capacity/sizes or description including cleaning all filtn/silt, foreign materials and other deposits whatsoever completely and making the septic tank free from all obstacles.The cleaning operation will be carried out in suitable TNP and removing the silt/sludge and pumping out fluid, cleaning of sludge from compartment of septic tank including intercepting chamber & washing down with water complete and removing the sludge in covered van/trolley outside the MD land, complete, all as directed.
Cleaning of manholes depth upto 1.5 mtr by removing all filtn/silt, foreign materials and other deposits whatsoever completely and making the Manholes free from all obstacles.The cleaning operation will be carried out in suitable TNP and removing the all silt, sludge, any other materials making clean and flushing with water complete incuding removal of spoils outside MD land and taken out cover slab and reset in the same position after cleaning and testing all as specified and directed. cleaning shall be done either manually or mechanically as required and directed by Engr-in-charge.
All as per description of serial item No. 6.00 here-in-before but depth exceeding 1.5 mtr and not exc 3 mtr deep complete all as specified and directed.
All as per description of serial item No. 6.00 here-in-before but depth exceeding 3.0 mtr and not exc 4.5 mtr deep complete all as specified and directed.
Cleaning of all blockages of Nahani trap/floor trap, bottle trap, gully trap, P or S traps of WCs, 100 mm/75 mm dia CI pipe stacks upto 1st Manhole, CI/SGSW pipe between gully trap & 1st Manhole, CI Tee/Door bends etc to maintain internal sewage system in the area of AGE B/R Gandhinagar and including manual/pressure cleaning pump & flexible rods and other necessary equipments complete all as specified and directed by Engr-in-Charge. Note : (i) Contractor or his authorised representative collect such type of complaints from AGE B/R Gandhinagar complaint cell at 8.30 AM on daily basis except sunday /Holiday. No extra payment shall be made on account of collection of complaint. (ii) Complaint must be completed within 24 hours without any fail otherwise recovery shall be made double the market rate to the contractor.
S&F, in repair, HDPE water storage tank lid black (with arrangement for locking for 500/1000 litres capacity tank complete all as specified and directed by Engineer-in-Charge.
Providing and laying 75mm thick for precast SFRC drain/manholes cover without frame but including complete sides iron sheets (medium ) complying to the standard specifications as mentioned in the IS 12592 BIS Standard minimum load bearing capacity 5 ton /Sqm in circular,square or rectangular shape complete all as specified and directed by Engr-in-Charge. Note :- All Reinforcement and iron sheet including formwork,concrete complete the rate quoted by tenderer is deemed to included in item shall be made good by contractor without any extra cost to the Govt.
Providing and laying 50mm thick for precast SFRC drain cover without frame but including complete sides iron sheets (medium ) complying to the standard specifications as mentioned in the IS 12592 BIS Standard minimum load bearing capacity 3 to 4 ton /Sqm in circular , square or rectangular shape complete all as specified and directed by Engr-in-Charge. Note :- All Reinforcement and iron sheet including formwork,concrete complete the rate quoted by tenderer is deemed to included in item shall be made good by contractor without any extra cost to the Govt.
Cleaning/opening the blockage sewage line of any size and depth all filtn/silt, foreign materials and other deposits whatsoever completely, and making the line free from all obstacles and testing the flow of sewer line evenly, smoothly by filling water. The cleaning operation will be carried out in suitable lengths by blocking the first and last manholes of sewage line and removing the silt/sludge & other deposits using Mechanical Jetting machine vehicle out side of MD land in covered van/trolley, all as specified & directed.
Demolition of brick/stone masonry built in cement/lime mortar of any mix including all quoins pillar ashlars masonry and removal complete all as specified& directed.
M&L for Brickwork with subclass ‘B’ bricks, (OLD SIZE BRICKS) straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified.
All as in item 15, but except bricks
M&L for PCC 1:3:6 type C1 (using 20 mm gradded stone agg )as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, drain channels, copings,parapets copings, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directed.
M&L for cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement Note : Forming fair finished channel for drain using extra cement shall be measured and paid for separately.
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, mixed with water proofing admixture (ISI marked), finished even & smooth without using extra cement complete all as specified. Note : - Supply only water proofing admixture shall be measured and paid for separately.
M&L for rendering 15mm thick in cement plaster 1:4 on stone masonry surfaces or surfaces other than fair face of brick work of walls, mixed with water proofing admixture (ISI marked) finished even & smooth without using extra cement complete all as specified. Note : - Supply only water proofing admixture shall be measured and paid for separately.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified & directed by Engr-in-Charge.
Demolition of reinforced cement concrete as in cover/slab of drain/culvert/septic tank/soakage well all a specified & directed by Engineer-in-Charge.
M&L for precast RCC 1:2:4 type C1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including placing in position and set in CM (1:6) complete all as specified & as directed. Note :- Reinforcement shall be measured and paid for separately.
M&L Mild steel TMT bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to TMT bar complete all as specified and directed by Engr-in-Charge.
Demolition and breaking up drain pipes 150 mm dia (salt glazed ware AC or reinforcement concrete set in cement mortar pipes) complete all as specified and directed.
M&L 150 mm Salt glazed stonware pipe laid and jointed complete with collars and set joint in cement mortar 1:4 complete all as specified and directed.
M&L 150 mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars and set joint in cement mortar 1:4 complete all as specified and directed.
Demolition and breaking up drain pipes 200 mm dia (salt glazed ware AC or reinforcement concrete set in cement mortar pipes) complete all as specified and directed.
M&L 200 mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars and set joint in cement mortar 1:4 complete all as specified and directed.
Demolition and breaking up drain pipes 300 mm dia (salt glazed ware AC or reinforcement concrete set in cement mortar pipes) complete all as specified and directed.
M&L 300 mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars and set joint in cement mortar 1:4 complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate for 150 mm dia bore drain pipe for bed concrete including packing under and hunching against the sides of pipe after they are laid and tested complete.
All as per item No 33 above ditto but 200mm dia bore pipe
All as per item No 33 above ditto but 300mm dia bore pipe
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out
All as per item No 36 above exc 1.5 m deep and n.exc 3 m deep.
M & L cement conc. 1:4:8 type D2 (40 mm graded aggregate) as in foundation, filling and mass conc complete all as specified.
Returning filling in including spreading, levelling watering and well ramming in layers not exc. 25 cm using excavated soil.
Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point
M&L for 150mm dia Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed by Engr-in-Charge.
S&F 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors including demolition old u/s pipe complete all as specified
S&F in repair 150x150mm Salt-glazed stoneware gully traps, square or round mouthed, type `P' all as directed and specifed.
Disconnecting & dewatering of PVC overhead taks, scrubbing the inner surfaces, cleaning & removing all scales, dirt etc from mouth of circulating pipes, washing the tanks with fresh water and disinfecting the same by flushing with liquid chlorine or any other equivalent chemical, reconnecting & refixing in position after cleaning for tank capacity not exc 500 ltrs each including marking the date of cleaning with white paint and stencil all as required & directed. Note: Cleaning shall be done through wash out pipe by marking suitable arrangement to the outlet pipe such as cutting of the pipe providing short piece of pipe fitting and union coupling etc where the wash out pipe are not existing. The dirt etc shall not be allowed to enter the water supply system.
All as per serial item No 44 here-in-above but exc 500 ltr and not exc 1000 ltrs capacity.
S&F Rotational moulded polyethylene water storage tanks( white colour) (cylindrical vertical with closed top) of capacity 500 Ltrs hoisted and fixed in position all as specified in SSR Part I including dismantaling existing water tanks and removing to store, complete all as specified and directed.
All as per serial item No 46.00 here-in-above but 1000 ltrs capacity.
S&F in repair ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed of 20mm dia, minimum weight - 210 gms all as directed by Engr-in-Charge.
Taking up or down 15mm steel tubing and connections, including cleaning for re-fixing or removal to store
Taking up or down 20mm steel tubing and connections, including cleaning for re-fixing or removal to store
S&F, steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 15mm bore of pipe complete all as specified and directed by Engineer-in-Charge.
S&F, steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 20mm bore of pipe complete all as specified and directed by Engineer-in-Charge.
Taking up or down 25/32mm steel tubing and connections, including cleaning for re-fixing or removal to store
S&F, steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 25mm bore of pipe complete all as specified and directed by Engineer-in-Charge.
Refixing old serviceable steel tubing and connections in new or old position (walls, ceilings, floors etc.) for 15/20mm bore of pipe complete all as specified and directed by Engineer-in-Charge.
Refixing old serviceable steel tubing and connections in new or old position (walls, ceilings, floors etc.) for 25mm bore of pipe complete all as specified and directed by Engineer-in-Charge.
Shree Builders (BID ID -3084623)
ALBA AC AND REF SERVICES (BID ID -3086879)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .