Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC TEHSIL SARKAGHAT P O RAKHOH VILL GADHANI SARKAGHAT MANDI HP 175024 | MANDI | HIMACHAL PRADESH | 175024 | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER | |
| 2 | L2₹9.2 L+₹22,278 (2.49%)Rejected-AOC | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 3 | L3₹9.8 L+₹85,325 (9.53%)Rejected-AOC | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 4 | L4₹10.8 L+₹1.9 L (20.8%)Rejected-AOC 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 5 | L5₹12.0 L+₹3.1 L (34.3%)Rejected-AOC 00 KHATA NO 514 4357 PLOT NO 169 3484 KESHARA BHUBANESWAR KHURDA KHORDHA ODISHA 751007 | KHORDHA | ODISHA | 751007 | L5 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
| Sl No | Description | Qty | Unit | Sai Enterprises L5 | AIRCOM L2 | Bedi Refrigeration Works L4 | PANTECH INSTRUMENTS AND SERVICES L3 | VATANUCOOL ENGINEERS L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Disconnecting, dismantling and taking out the existing Air conditioner Split type of any description, any make and in any position 1.5 TR/2 TR capacity, both indoor and outdoor unit single phase, strip opening , cleaning and servicing of the AC with using caustic soda/detergent solution, cleaning of suction air filter and coil of indoor unit and brazing the discharge and suction line, reassembling, fixing and testing of the AC complete, all as specified and directed.
Note: (Applicable for Sch ‘A’ Item No.1& 2). (i) Window/Split type AC's shall be taken from department on "as and where installed" basis.
(ii) Window/Split type AC's are to be maintained for heating as well cooling , where this provision is in the machine.
(iii) The spare parts measured & paid separately as supply only rates. Rate for fixing of spare parts (ie compressor, condensing coil, cooling coil & blower motor) under relevant items shall be included in item No.1&2).
(iv) The contractor shall ensure and asses at the site any initial maintenance required, to make the all Window/Split type AC's in proper working condition, at the time of taking over and he shall be laible to make all listed handed over units functional. (ii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item. | 175 | Each Job | 750 ₹1,31,250 | 400 ₹70,000 | 250 ₹43,750 Lowest | 400 ₹70,000 | 500 ₹87,500 |
| 2.00 | Supply only repaired compressor sealed unit of suitable capacity/ model in the unit properly for 1.5/2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH ) | 3 | Each | 4,800 ₹14,400 | 4,500 ₹13,500 | 5,500 ₹16,500 | 7,000 ₹21,000 | 2,500 ₹7,500 Lowest |
| 3.00 | Supply only new Rotory type compressor sealed unit of suitable capacity/ model in the unit properly for 1.5 TR/2 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH ) | 3 | Each | 4,000 ₹12,000 Lowest | 5,700 ₹17,100 | 8,500 ₹25,500 | 5,000 ₹15,000 | 10,000 ₹30,000 |
| 4.00 | Supply only new condensing coil unit for Split type AC of any type/ any capacity complete, all as specified and directed. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH ) | 3 | Each | 6,500 ₹19,500 | 6,200 ₹18,600 | 4,500 ₹13,500 | 1,000 ₹3,000 Lowest | 7,500 ₹22,500 |
| 5.00 | Supply only blower motor including fan blade, capacitor complete suitable for split type AC 1.5 ton/2.0 ton capacity 1/8 HP, 220 Volts, single phase complete, all as specified and directed. | 3 | Each | 550 ₹1,650 Lowest | 1,400 ₹4,200 | 1,800 ₹5,400 | 1,200 ₹3,600 | 1,500 ₹4,500 |
| 6.00 | M&L for charging refrigerant gas in the system of window/Split type AC of 1.5/2.0 ton capacity complete, all as specified and directed.
(Note : The refrigerant gas measured and paid separately under relevant items as applicable as ‘supply only’). | 25 | Each Job | 1,200 ₹30,000 | 500 ₹12,500 | 400 ₹10,000 Lowest | 1,000 ₹25,000 | 400 ₹10,000 Lowest |
| 7.00 | M&L for replacement of unserviceable starting capacitor 80/100 MFD 230 V AC for window/Split type AC 1.5 Ton/2.0 Ton capacity/water cooler complete, all as specified and directed. (Make : Universal/Sarda ) | 2 | Each | 10 ₹20 Lowest | 90 ₹180 | 150 ₹300 | 150 ₹300 | 50 ₹100 |
| 8.00 | M&L for replacement of unserviceable running capacitor 36/45/50 MFD 230 V for window/Split type AC 1.5 Ton/2.0 Ton capacity complete, all as specified and directed. (Make : Universal/Sarda ) | 4 | Each | 200 ₹800 | 220 ₹880 | 350 ₹1,400 | 200 ₹800 | 50 ₹200 Lowest |
| 9.00 | M&L for replacement of unserviceable overload protection coil (1622) 230 Volts for window/Split type AC 1.5 Ton/2.0 Ton capacity complete, all as specified and directed. | 2 | Each | 5 ₹10 Lowest | 60 ₹120 | 150 ₹300 | 100 ₹200 | 50 ₹100 |
| 10.00 | M&L for replacement of unserviceable Relay (1622) suitable for window/Split type AC 1.5 Ton/2.0 Ton capacity complete, all as specified and directed. | 2 | Each | 5 ₹10 Lowest | 60 ₹120 | 200 ₹400 | 120 ₹240 | 50 ₹100 |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
20 May 2025, 6:00 pmClosed
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
REPAIR /MAINT AND SERVICING OF FANS AC REFRIGERATOR WATER COOLER GEYSERS AT TECH AND RESIDENTIAL AREA AT IRDE UNDER GE (I) RND DEHRADUN
2025_MES_704940_1
GE(I)RND/9462/E8/25-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Dehradun
Class E Category c (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 and 1.5 of section of Part I of MES Manual on contracts-2020 as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
Yes
GE I RND DEHRADUN
₹28,000
Yes
11 Aug 2025
22 Apr 2025
22 May 2025
22 Apr 2025
20 May 2025
6 May 2025
22 Apr 2025 - 6 May 2025
Amount
Disconnecting, dismantling and taking out the existing Air conditioner Split type of any description, any make and in any position 1.5 TR/2 TR capacity, both indoor and outdoor unit single phase, strip opening , cleaning and servicing of the AC with using caustic soda/detergent solution, cleaning of suction air filter and coil of indoor unit and brazing the discharge and suction line, reassembling, fixing and testing of the AC complete, all as specified and directed. Note: (Applicable for Sch ‘A’ Item No.1& 2). (i) Window/Split type AC's shall be taken from department on "as and where installed" basis. (ii) Window/Split type AC's are to be maintained for heating as well cooling , where this provision is in the machine. (iii) The spare parts measured & paid separately as supply only rates. Rate for fixing of spare parts (ie compressor, condensing coil, cooling coil & blower motor) under relevant items shall be included in item No.1&2). (iv) The contractor shall ensure and asses at the site any initial maintenance required, to make the all Window/Split type AC's in proper working condition, at the time of taking over and he shall be laible to make all listed handed over units functional. (ii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item.
Supply only repaired compressor sealed unit of suitable capacity/ model in the unit properly for 1.5/2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )
Supply only new Rotory type compressor sealed unit of suitable capacity/ model in the unit properly for 1.5 TR/2 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )
Supply only new condensing coil unit for Split type AC of any type/ any capacity complete, all as specified and directed. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )
Supply only blower motor including fan blade, capacitor complete suitable for split type AC 1.5 ton/2.0 ton capacity 1/8 HP, 220 Volts, single phase complete, all as specified and directed.
M&L for charging refrigerant gas in the system of window/Split type AC of 1.5/2.0 ton capacity complete, all as specified and directed. (Note : The refrigerant gas measured and paid separately under relevant items as applicable as ‘supply only’).
M&L for replacement of unserviceable starting capacitor 80/100 MFD 230 V AC for window/Split type AC 1.5 Ton/2.0 Ton capacity/water cooler complete, all as specified and directed. (Make : Universal/Sarda )
M&L for replacement of unserviceable running capacitor 36/45/50 MFD 230 V for window/Split type AC 1.5 Ton/2.0 Ton capacity complete, all as specified and directed. (Make : Universal/Sarda )
M&L for replacement of unserviceable overload protection coil (1622) 230 Volts for window/Split type AC 1.5 Ton/2.0 Ton capacity complete, all as specified and directed.
M&L for replacement of unserviceable Relay (1622) suitable for window/Split type AC 1.5 Ton/2.0 Ton capacity complete, all as specified and directed.
M&L for replacement of unserviceable capillary tube and stainer for window/Split type AC of 1.5 ton/2.0 ton capacity complete, all as specified and directed.
M&L for replacement of unserviceable PVC air filter for Split type AC of 1.5 ton/2.0 ton capacity complete, all as specified and directed.
M&L for replacement of unserviceable capacitor for blower motor suitable for window /Split type AC 1.5 ton/2.0 ton capacity complete, all as specified and directed.
M&L for replacement of unserviceable fan blade for blower motor suitable for window /Split type AC 1.5 ton/2.0 ton capacity complete, all as specified and directed.
M&L for replacement of unserviceable swinging motor with louvers as per existing make for Split type AC 1.5 ton/2.0 ton capacity complete, all as specified and directed.
M&L for replacement of unserviceable remote control assembly with PCB plate complete with connections suitable for Split AC 1.5TR/2TR single phase capacity complete all as specified and directed .
M&L for replacement of unserviceable Inverter PCB for Indoor complete with connections suitable for Split AC 1.5TR/2TR single phase capacity complete all as specified and directed .
M&L for replacement of unserviceable Inverter PCB for outdoor complete with connections suitable for Split AC 1.5TR/2TR single phase capacity complete all as specified and directed .
M&L for replacement of unserviceable LCD / LED display unit for Window/split type AC 1.5 / 2.0 ton capacity complete, all as specified and directed.
M&L for replacement of unserviceable 15/20 mm bore PVC flexible conduit complete, all as specified and directed.
Supply and fixing in replacing refrigerant copper tubing 5/8" / 1/2" dia (as per existing one) with 22 gauge , fixed on wall / ceiling with saddle as per site requirement including making joints by brazing / flairing and checking for any leakage complete, all as specified and directed.
Supply and fixing in replacing refrigerant copper tubing 3/8" / 1/4" dia (as per existing one) with 22 gauge , fixed on wall / ceiling with saddle as per site requirement including making joints by brazing / flairing and checking for any leakage complete, all as specified and directed.
Supply and fixing in replacment foam type insulation sleeve for copper tubing 5/8" / 1/2"/ 3/8" / 1/4" dia (as per existing one) binding and securing the insulation firmly with copper tubing as per site requirement complete, all as specified and directed.
M&L for replacement of unserviceable reverse cycle valve in window/Split type AC of 1.5 / 2 TR cap. and welding, brazing with copper tubing and testing complete all as specified and directed. Make : Renutrol/Pacific
M&L for dismantling of storage type water cooler of 40/80/150 ltrs capacity of existing model in various location, shifting to MES Yard for repair/replacement of unserviceable spares and painting the outer body (including replacement of corroded sheet with new one) by spraying enamel paint and reassembling, testing, checking and shifted to existing location, fixing the same by nut, bolt, angle iron structure and masonry work all as directed & specified by Engineer-in-Charge. (NOTE: The spare parts ( ie. compressor, blower motor) measured & paid separately as supply only rates. Rates for fixing of spares parts under the unit rate quoted by the contractor for this item.
Supply only new compressor sealed unit of 40/80/150ltrs capacity of existing model in the unit properly for storage type water cooler of any type complete, all as specified and directed.(Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )
Supply only blower motor including fan blade, capacitor complete suitable for 40/80/150 ltrs capacity, 220 volts, single phase complete, all as specified and directed.
Supply only new condensing coil unit suitable for40/80/150 ltrs capacity, 220 volts, single phase complete, all as specified and directed.
M&L for charging refrigerant gas in the system of water cooler of any capacity complete, all as directed by Engr-in-charge. (Note : The refrigerant gas measured and paid separately under relevant items as applicable as supply only).
M&L for replacement of unserviceable capillary tube and stainer for storage type water cooler of 40/60/150 ltrs capacity complete, all as specified and directed.
M&L for replacement of unserviceable overload protection coil 230 volts for water cooler of 40/60/150 ltrs capacity complete, all as specified and directed.
M&L for replacement of unserviceable relay suitable for water cooler of 40/60/150 ltrs capacity complete, all as specified and directed. ( Make : Indfoss / Usha / Arvind)
M&L for replacement of unserviceable thermostat suitable for water cooler of 40/60/150 ltrs capacity icomplete, all as specified and directed.(Make : Indfoss/Asian).
M&L for replacement of unserviceable starting capacitor 1.5/2.0 MFD 230 V AC for water cooler of capacity 40/60/150 ltrs complete, all as specified and directed. (Make : Universal/Sarda )
M&L for replacement of unserviceable running capacitor suitable for water cooler of capacity 40/60/150 ltrs complete, all as specified and directed. (Make : Indfoss/Sarda).
M&L for replacement of unserviceable fan blade for water cooler of 40/60/150 ltrs capacity complete, all as specified and directed.
M&L for replacement of unserviceable capacitor for blower motor suitable for water cooler of 40/60/150 ltrs capacity complete, all as specified and directed.
M&L for replacement of unserviceable internal wiring of AC, water cooler, refrigerator of any capacity and rewiring the same with 2.5 Sqmm size multi stranded copper cable incl testing checking etc complete, all as specified and directed.
M&L for replacement of head cover gasket for water cooler of 40/60/150 ltrs capacity complete, all as specified and directed.
Supply only refrigerant gas R-22.
Supply only refrigerant gas 134A.
Supply only refrigerant gas R-407/R-410 (HYDRO CARBON)
M&L for replacement of angular valve of size 1/2" suitable for split type AC complete. all as specified & directed by Engineer-in-Charge
M&L for replacement of angular valve of size ¼" suitable for split type AC complete. all as specified & directed by Engineer-in-Charge
M&L for replacement of angular valve of size 5/8" suitable for split type AC complete. all as specified & directed by Engineer-in-Charge
M&L for replacement of angular valve of size 3/8" suitable for split type AC complete. all as specified & directed by Engineer-in-Charge
Supply only Remote control for split/ Window type AC of LG/Samsung/existing make of 1.5 TR/2 TR with battery complete,all as specified & directed by Engineer-in-Charge.
M & L for dismantling of unserviceable voltage stablizer of capacity 3 KVA/4 KVA/5 KVA in various location for repair/replacement of unserviceable parts, cleaning, servicing, checking, reassembling, testing and handed over to MES in serviceable condition all as specified and directed by Engr-in-Charge (Note :- The spare parts measured and paid separately as supply only rates. Rates for fixing of spare parts under relevant items shall be included in item)
Installation only split type AC including indoor/outdoor unit of capacity 1.5 Ton/2 Ton after carried out the repair under item No.2 at new location as directed including providing necessary chiseling/ cutting for fix the indoor/outdoor unit by means of suitable size of nut, bolt, angle iron structure, masonry work and making good the disturbed surface with PCC, plastering,white wash works,testing & checking complete,all as directed & specified by Engineer-in-Charge. (Note :- The spare parts measured & paid separately as supply only rates. Rate for fixing of spare parts (ie compressor, condensing coil, blower motor and nut bolt angle iron structure) under relevant items shall be included in this item) complete. all as directed by Engineer-in-Charge.
Supply &Fixing in replacement of unserviceable Oudoor unit body complete with out compressor unit suitable for existing Split type AC of 1.5 TR capacity, all as specified and directed by Engr-in-Charge.
Supply &Fixing in replacement of unserviceable indoor unit body complete suitable for existing Split type AC of 1.5 TR capacity, all as specified and directed by Engr-in-Charge.
Supply &Fixing in replacement of unserviceable mild steel work as split type AC outdoor/water cooler wheel stand /supporting /protection cage etc. of suitable size of flat iron/Angle iron etc.,cut to shape, including bending and welding as necessary, etc.conforming to Fe.290.Gde-E-165, with and including applying two coats of synthetic enamel paint over a coat of red oxide primer complete, all as specified and directed.
Supply &Fixing in replacement of unserviceable plug top 3 pin, 15/16 Amp capacity complete all as specified and directed. Make : Anchor (Penta deluxe) or equivalent as approved by GE.
Disconnecting and removing the water and electric connections carefully from the existing Geyser of capacity 25/50 ltrs, any make and taking out the same in any position from the existing location. cleaning and de-scaling the inner tank using de-scaling solution mixed with water in suitable proportion till the complete deposits /scale is removed as approved by Engineer-in-Charge, brazing for stopping leakage of copper inner tank/gas welding for inner steel tank, re- assembling the complete Geyser after cleaning, Fixing and installation of Geyser in position and testing to the entire satisfaction of Engineer-in-Charge. Opening the Geyser for inspection, repairs and reassembling the same as per the original assembly after repairs/ replaceing the wourn out unserviceable parts with new parts as ordered including re-fixing same position of the Geyser and making electric connection, water inlet and outlet connection, testing and checking of all the functioning of water inlet outlet valves connected with geysers.all as specified and directed by Engr-in-Charge. Note :- Spare parts if any requires replacement shall be measured and paid for separately.
Supply only Rubber PVC gasket to ensure water tightness for 25/50 liters capacity complete, all as specified and as directed by Engr-in-charge.
Supply only MS base plate cup any type with screws of suitable size as per requirement complete, all as specified and as directed by Engr-in-charge.
Supply only Heating element of the 1.5/2 KW rating as required at site including rubber washers of any make and type complete, all as specified and as directed by Engr-in-charge
Supply only Steel inner tank of 25 litre capacity geyser tank by made out of steel sheets appropriate thickness complete, all as specified and as directed by Engr-in-charge.
Supply only Steel inner tank of 50 litre capacity geyser tank by made out of steel sheets appropriate thickness complete, all as specified and as directed by Engr-in-charge.
Supply only Thermostat with setting range 30°C to 80°C suitable for 230 volts AC, electric supply complete all as specified and directed, Make – Recold / Bajaj,/ Daspass
Supply only Non return valve 15 mm dia cast copper alloy ISI mark complete, all as specified and as directed by Engr-in-charge.
Supply only Safety valve/Fusible plug 15mm complete, all as specified and as directed by Engr-in-charge.
Supply only Chromium plate copper connecting tube 450 mm long with two brass adopters suitable for 15 dia pipe and connecting up complete with washers complete, all as specified and as directed by Engr-in-charge.
Supply only PVC connecting tube 450 mm long with two brass adopters suitable for 15 mm dia pipe and fixing in position ,superior quality as approved by Engineer-in-charge.
M&L in replacement of unserviceable bottom plate of geysers 25/50 liters capacity, same sizes and shape complete all as specified & directed.
M&L in replacement of unserviceable air release valve 15 mm bore for geyser as per existing type complete all as specified and directed.
M&L in replacement of unserviceable Indicating lamp of size /shape as per existing suitable for 230 Volts AC supply. complete all as specified and directed
Supply only assembly type round heating element of the 1.5/2 KW rating as required at site including rubber washers of any make and type complete, all as specified and as directed by Engr-in-charge
Supply only PVC hot and cold connecting tube 600 mm long with two brass adopters suitable for 15 mm dia pipe and fixing in position ,superior quality as approved by Engineer-in-charge.
Supply only Thermostat bellow type with setting range 00°C to 80°C suitable for 230 volts AC, electric supply complete all as specified and directed, Make – Recold / Bajaj,/ Daspass
Supply and fixing fastener of size 3" /4" fixing of geyser complete all as specified and directed.
Supply and fixing 'U' assembly 6 hole for 25 ltr geyser complete all as specified and directed.
Supply and fixing 'U' assembly 6 hole for 50 ltr geyser complete all as specified and directed.
Supply and fixing 'U' assembly 9 hole for 25 ltr geyser complete all as specified and directed.
Supply and fixing 'U' assembly 9 hole for 50 ltr geyser complete all as specified and directed.
Disconnecting , taking down & removing carefully the existing ceiling fan etc. of any description, any sweep and from any position / locations (i.e. Md Accn/ OTM Accn / Md Hostel/ Workshop/ Installations etc) for repairs / servicing / overhauling / painting / numbering etc., dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, hanging / fixing the repaired fans in position, connecting to existing electric sources and testing at site to the entire satisfaction of Engineer-in-Charge complete, all as specified and directed.
Disconnecting , taking down & removing carefully the existing exhaust fans etc. of any description, any sweep and from any position / locations (i.e. Md Accn/ OTM Accn / Md Hostel/ Workshop/ Installations) for repairs / servicing / overhauling / painting / numbering etc., dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, hanging / fixing the repaired fans in position, connecting to existing electric sources and testing at site to the entire satisfaction of Engineer-in-Charge complete, all as specified and directed.
Disconnecting,taking down and removing carefully the existing table fan, Air circulator wall mounting fan,pedestal fan, of any description, any sweep and from any position / locations for repairs / servicing / overhauling / painting / numbering etc., dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, connecting the fans to existing electric sources and testing at site to the entire satisfaction of Engineer-in-Charge complete, all as specified and directed. Note for item 1 to item 3 here in before : (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include for transportation to & fro of fans to workshop if required and approved by the Engineer-in-charge for necessary repairs. (iv)Cost of minor repair i.e. loose connection tightening, oiling greasing, tightening nut- bolts, insulating wire etc deemed to be inclusive in the item rate above. (v) Writing of fan No. and painting of fans shall be measured and paid for separately under appropriate item of Sch ‘A’
Supplying only ball bearing No 6200 (Make SKF/NRB/NBC)
Supplying only ball bearing No 6201 (Make SKF/NRB/NBC)
Supplying only ball bearing No 6202 (Make SKF/NRB/NBC)
Supplying only ball bearing No 6203 (Make SKF/NRB/NBC)
Supply only gun metal bushes of any description and size to suit existing motor shaft.
Supplying only capacitor of capacity 2.5 mfd (PVC body) (Make:- EPCOS/JYOTI/ USHA)
Supplying only capacitor of capacity 4 mfd (PVC body) (Make:- EPCOS/JYOTI/USHA)
Supply only complete hanging assembly set comprising with rubber reel, MS clamps, nuts, bolts with lock pins suitable for any type of fans & down rods of length 300mm.
Supplying only PVC fan blade assembly with necessary MS nuts, bolts & washers suitable for exhaust fans of any descriptions & of 200/-250/300 mm sweep. (Note: Set of three blades shall be measured as one unit and make of assembly shall be as approved by GE.)
Supplying only aluminium cast metal fan blade assembly with necessary MS nuts, bolts & washers suitable for exhaust fans of any descriptions & of 200 to/450 mm sweep. (Note: Set of three blades shall be measured as one unit and make of assembly shall be as approved by GE.)
Supply only MS tube medium grade 15mm dia duly finished with white colour two coats over a coat of red oxide cutting in desired length from 300mm to 1500mm, cutting slot and drilling hole for down rod of fan complete all as specifieda and directed.
Taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire (Make : Atlas/Finolex/Devi Dayal)as approved by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of Engineer-in-charge for the following Fans:-
Rewinding of motor of ceiling fans 1200 mm sweep.
Rewinding of motor of ceiling fans 1400 mm sweep.
Rewinding of motor of exhaust fan of 230/300 mm sweep.
Rewinding of motor of exhaust fan of 450 mm sweep.
Rewinding of motor of wall mounted fan of 400 mm sweep.
Rewinding of motor of air circulating fan of 610 mm sweep.
Rewinding of motor of table fan/ pedestal fan of 400 mm sweep.
Taking down existing worn out louvers of any description , in any position and supplying & fixing new louvers for exhaust fan of 230/300mm sweep complete all as specified & directed. ( Note: The louvers shall be of shape, size and pattern as approved by the Engineer-in-Charge duly painted with two coat of synthetic enamel paint over a coat of red oxide primer)
Taking down existing worn out louvers of any description , in any position and supplying & fixing new louvers for exhaust fan of 450mm sweep complete all as specified & directed. ( Note: The louvers shall be of shape, size and pattern as approved by the Engineer-in-Charge duly painted with two coat of synthetic enamel paint over a coat of red oxide primer)
Disconnecting & taking out old existing unserviceable ceiling fan regulator of any description & in any position / location and Supply and fixing ceiling fan regulator electronic, step type suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply complete all as specified & directed. (Make :- Anchor/Cona/Havells/Legrand/HPL)
M & L for painting of existing fans of any description of ceiling fan of 1200/1400mm sweep with applying one coat of synthetic enamel paint (White) by spray machine including preparation of existing decorated surfaces of fans complete, all as specified and directed.
M & L for painting of existing fans of any description of exhaust fan of 230/300/450mm sweep with applying one coat of synthetic enamel paint grey by spray machine including preparation of existing decorated surfaces of fans complete, all as specified and directed.
Supplying and fixing GI tubing 40mm, medium grade for hanging of ceiling fans including cutting holes in walls built in cement mortar and making good in cement sand mortar 1:4 and finish the surface to match with existing complete, all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor, complete, all as specified and directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm complete, all as specified and directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete, all as specified and directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm complete, all as specified and directed.
Supply and fixing wall mounted fan of, 230 V, 50 Hz, 1350 RPM, 400 mm sweep, Min air delivery 72 CFM complete, all as specified and directed.
AIRCOM (BID ID -3296345)
PANTECH INSTRUMENTS AND SERVICES (BID ID -3299509)
Bedi Refrigeration Works (BID ID -3301226)
Sai Enterprises (BID ID -3294962)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .