Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC D NO CC XX 1487 B1 CC 18 1786 B1 NEAR VVLP SCHOOL KONAM PALLURUTHY P O KOCHI 682006 | ERNAKULAM | KERALA | 682006 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹25.2 L+₹2.0 L (8.62%)Rejected-Finance 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹25.9 L+₹2.7 L (11.5%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹48,000
Closing Date
14 Aug 2021, 6:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2021_MES_461198_1
GE MAINT EZHIMALA 8395
Open Tender
Civil Works
Item Rate
180 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹48,000
Yes
2 Sept 2021
19 Jul 2021
16 Aug 2021
19 Jul 2021
14 Aug 2021
2 Aug 2021
20 Jul 2021 - 27 Jul 2021
Amount
Taking down existing walk in chiller (Cold Room) with cold storage rack of any type by carefully removing the electrical connections and cables from the existing locations and deposite to AGE E/M store complete all as specified and as directed by the Engg-in-charge.
Supply and installation of walk in chiller units indoor/ outdoor complete (size 11.10"x6.75"x8.00") refrigerant R407C suitable for three phase AC supply complete with copper condenser including the following specification all as specified and as directed by the Engg-in-charge:- (a) Model No - CR-1 (b) Panel Thickness - 60mm (c) Door Size (850x1950mm) - 01No (d) Prod loading Kgs/Dav - 313 (e) Incoming Temp in Deg C - 30 (f) Final Room Temp Deg C - +2 to +8 (g) Offered Ref Capacity in BTU/Hr - 10000 (h) Refrigerant - R407C (j) Air Cooled Unit - CCO-127-HA (k) Condencing - Air Cooled (l) Defrosting - Air off cycle (m) Evaporator - CSCI-08-SS (n) Compressor - Emerson/Tecumseh Make: Celfrost / Desmon-Italy / Foster UK
M&L for SS 304 Cold Room storage rack of size 4.0"x1.8"x5.6" constructed of 5 shelf starting at 150mm and then equal distance constructed with 38mm dia SS pipe of 16 SWG SS 304 under support 18 SWG 304 SS shelf, double beaded on all side & 4 Nos 38mm SS 304 tubular legs with heavy duty nylon adjustable bullet feet complete all as specified and as directed by the Engg-in-charge.
Supply and installation walk in chiller units indoor/ outdoor complete with (size 9.30"x 8.00"x8.00") refrigerant R407C suitable for three phase AC supply complete with copper condenser including the following specification all as specified and as directed by the Engg-in-charge:- (a) Model No - CR-2 (b) Panel Thickness - 60mm (c) Door Size (850x1950mm) - 01No (d) Prod loading Kgs/Dav - 311 (e) Incoming Temp in Deg C - 30 (f) Final Room Temp Deg C - +2 to +8 (g) Offered Ref Capacity in BTU/Hr - 10000 (h) Refrigerant - R407C (j) Air Cooled Unit - CCO-127-HA (k) Condencing - Air Cooled (l) Defrosting - Air off cycle (m) Evaporator - CSCI-08-SS (n) Compressor - Emerson/Tecumseh Make: Celfrost / Desmon-Italy / Foster UK
M&L for SS 304 Cold Room storage rack of size 3.6"x1.8"x5.6" constructed of 5 shelf starting at 150mm and then equal distance constructed with 38mm dia SS pipe of 16 SWG SS 304 under support 18 SWG 304 SS Shelf, double beaded on all side & 4 Nos 38mm SS 304 tubular legs with heavy duty nylon adjustable bullet feet complete all as specified and as directed by the Engg-in-charge.
Supply and install Walk in Freezer units indoor/ outdoor complete with (size 6.20"x 8.00"x8.00") refrigerant R404A suitable for three phase AC supply complete with copper condenser including the following specification all as specified and as directed by the Engg-in-charge:- (a) Model No - FR-2 (b) Panel Thickness - 100mm (c) Door Size (850x1950mm) - 01No (d) Prod loading Kgs/Day - 115 (e) Incoming Temp in Deg C : -10 (f) Final Room Temp Deg C : -18 to -20 (g) Offered Ref Capacity in BTU/Hr - 6000 (h) Refrigerant - R404A (j) Air Cooled Unit - CFO-084-HA (k) Condencing - Air Cooled (l) Defrosting - Electric (m) Evaporator - CKFI-08-SSX (n) Compressor - Emerson/Tecumseh Make: Celfrost / Desmon-italy / Foster UK
M&L for SS 304 Cold Room storage rack of size 3.6"x1.8"x5.6" constructed of 4 shelf starting at 150mm and then equal distance constructed with 38mm dia SS pipe of 16SWG SS 304 under support 18SWG 304SS Shelf, double beaded on all side & 4 Nos 38mm SS304 tubular legs with heavy duty nylon adjustable bullet feet complete all as specified and as directed by the Engg-in-charge.
Notes: For Item Ser No 2 to 7:- (a) Contractor may visit the site before quoting of tender to assess the actual requirement of works and no extra cost will be entertained on this account. (b) Out door unit comprising compressor with motor,air cooled copper condenser with fan and motor unit shall be installed outside the building/on roof top. (c) Refrigerant copper pipe for suction and discharge line with insulation, condensing water drain pipe & protected by suitable size of PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cables as per site requrement, all these items are to be provided by contractor and no extra cost will be paid to contractor on this account. (d) Making good the disturbed surface to match the existing surface after completion of installation work etc. (e) PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of indoor/outdoor unit or powder coated MS bracket fixed on wall / roof top as per manufacture's instruction with necessary grouting MS hold fast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor/indoor unit complete all as specified and as directed. (f) Contractor has to provide all types of tools, any type of materials required for cold room and contractor will be fully responsible for complete testing of plant after completion of work. (g) Contractor has to provide half yearly complete servicing upto 01 years (checking refrigerent pressure, loose connection,leakage of refrigerant,topup of refrigerant if required, servicing and cleanning of PCB) will be provided by OEM and no extra cost will be paid on this account.
M&L for replacement of sub main wiring complete using 4 runs of 10 sqmm and two runs of 10 sqmm PVC insulated unsheathed FRLSH multistranded copper conductor ISI marked 1100 V grade in surface/concealed PVC conduit fixed in wall/floor,passing through wall/ceiling complete all as specified and directed by Engr-in-Charge. Notes:- (i) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (ii) Six runs of cable and one run of conduit /cassing & capping with necessary accessories will be measured as one unit length. (iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
Suppy & fix in replacement for fixing sheet metal enclosures DBs 4 way double door with 200 amps rated bus bar complete all as specified and directed by Engr-in-Charge.
Suppy & fix MCB TPN 63 Amps complete all as specified and directed by Engr-in-Charge.
Jack Electrolinks Private Limited
devan enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .