Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 LAccepted-AOC | L1 | Accepted-AOC Bid accepted by tender Committee |
Tender Value
₹10.7 L
EMD Value
₹16,100
Closing Date
3 Sept 2021, 6:00 pmClosed
The Executive Engineer Electrical
O/o The chief Engineer, Harbour Engineering Electrical Division, Kamaleswaram,TVPM
Fisheries Station_Westhill_Renovation of existing rooms in Office building to Aquatic Animal Health Lab_Electrification
2021_HED_436163_1
26/HEED/2021-22/S
Open Tender
Electrical Works
Item Rate
90 days
Vellayil_West Hill_Kozhikode
Please refer Tender documents.
5 documents required · 5 mandatory
₹3,310
Yes
₹16,100
Yes
2 Dec 2021
25 Aug 2021
6 Sept 2021
25 Aug 2021
3 Sept 2021
25 Aug 2021
Amount
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Supply of 4 core 10 sq mm PVC insulated and PVC sheathed armoured aluminum cable
Supply of 4 core 6 sq mm PVC insulated and PVC sheathed armoured aluminum cable
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.upto 4 X 10sq. mm (28mm)
Providing and fixing10 SWG copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe on earth electrode including connection with copper thimble excavation and re-filling as required.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Earthing with GI earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.Group C
Supplying and fixing medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20mm
Supplying and fixing medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
Supplying and drawing following sizes of FR LSPVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 4 sq. mm
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supply and fixing 3/5 W LED ,BC, lamp OSRAM or equivalent
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6module metal box in recess
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3module metal box in recess
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 module metal box in recess
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.16A 1 way switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.RJ 11 Telephone jack
Supplying and fixing 6 way (4 + 18), Double door , horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 40A, four pole, (three phase and neutral), 415 volts,Residual current circuit breaker with Overcurrent Protection (RCBO), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing the following pole 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing the following pole 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
Supplying 21 W LED BattenTube light fitting 1200 mm BN021C LED20S PSU CDL 6500K Philips or equivalent
Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required (excluding reinforcement).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Mild steel and Medium Tensile steel bars
Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supply, fabrication, conveyance and fixing of 40 mm dia Medium class GI pipe with clamps made from 20 x 3 mm MS flat bent to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of epoxy paint over a coat of epoxy primer, making good the damages, colour washing etc as required (for the installation of outdoor light fittings).
Conveyance, installation, testing and commissioning of T 5 outdoor light fitting with FL lamps/LED/ SV/ MH/ CDMT light fittings with all accessories and lamp etc. of all types directly on the existing pipe/ pole including giving connections with the existing wiring etc as required
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing of surface/ recess mounting, vertical type, 415 volts,Dust and waterproof ,IP66 Hensel make or equivalent FP VN 0801 transparent door( 8 + 24 module) VTPN poly carbonate distribution board , with provision for MCCB as incomer, interconnection between incomer Isolator and bus bars of inclusive of125 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's painted, inclusive of , tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.
Supplying and fixing steel sheet 4 way prewired vertical type double door TP&N MCB distribution board with MCCB as incomer for 415 volts on surface/ recess complete with loose wire box of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FR PVC insulated copper conductor upto the terminal connector/ neutral link, earthing etc as required .
Supply, conveyance and fixing 40 A, 25 kA (Ics=100%Icu), 3pole, MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing DB as required
Supply of superior quality copper earth socket for the 3.15mm (10 SWG) earth conductor including crimping etc. as required.
Supplying Ultra sleek recessed downlight for low height false ceiling in square profile.DN097B LED10S-6500 PSU WH, >= 1000 lumens, 6500K .(Philips or equivalent)
Installation, testing and commissioning of pre-wired, LED light fitting of all types, complete with all accessories directly on ceiling after cutting the false ceiling to the required dimension including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supply of ceiling fans of 1200 mm sweep Category B Ceiling fan excluding resistance type regulator
Supply and fixing cast aluminium stove enameled elliptical shaped bulk head fittings with porcelain holder and mesh guard suitable for 3-14W LED lamps including connection etc as required.
Supply and installation of Hensel-Walther or equivalent make thermoplastic IP67,3PIN, 16A, 3P+N+E , IP67 weather proof, dust proof, environment friendly, recyclable, halogen & silicon free low toxicity low fume development anti-acid & anti-corrosive flame retardant wall mounting inter locking switched socket with provision for fixing 40A 4P RCCB
Supply and installation of Hensel-Walther or equivalent make thermoplastic IP67 weather proof, dust proof, environment friendly, recyclable, halogen & silicon free low toxicity low fume development anti-acid & anti-corrosive flame 3PIN.16A, 3P+N+E , IP67 plug top
Supply and drawing 3 core 1.0 sq.mm multi-core PVC insulated & PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections .
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required.
Supply and fixing 105 x 50 mm UPVC Cable Management System with base and lid LEGRAND or equivalent along with all required accessories as per the site condition on surface/recess including switch plate
Supply and fixing 80 x 50 mm UPVC Cable Management System with base and lid LEGRAND or equivalent along with all required accessories as per the site condition on surface/recess including switch plate
Numbering of ceiling fan/ exhaust fan as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and drawing 2 pair 0.5 sq mm FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Supplying and fixing following Modular base & cover plate on existing CMS as required.3 Module
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supply, installation, testing and commissioning of 3 KVA/2.4kW Online UPS Systems (Numeric Onfiniti , 1PH-1PH,FMI ) Floor Mountable Double conversion Pure Online UPS System( 72VDC or above) with built in Isolation Transformer ,Connecting in Standalone Configuration, Input Voltage 160V-280 VAC and output voltage :230V +/-1% , battery using 12 V C10 rated , 6 nos , 100AH Quanta/Exide make Tubular battery, recommended for 120 minutes backup (Minimum VAH 7200) and suitable Battery Rack for housing the batteries. The UPS should have ISO ,BIS,CE .PeP certification & RoHS marking. Warranty: 3 year onsite for UPS & 4 year for Battery
Supplying and fixing 12way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 40A, two pole, (single phase and neutral), 240 volts,Residual current circuit breaker with Overcurrent Protection (RCBO), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying Keselec Schreder make Street light luminaire 20W LED, an IP66 optical & control gear compartment, a die cast aluminium painted housing, Polycarbonate protector with in built lenses, with easily accessible control gear compartment, suitable for horizontal mounting (Ø32- 42mm), System power (including driver loss) of 20W with luminous efficacy > 90 Lumen/W at Ta 25⁰C. Lifetime residual flux @ Tq 35⁰C @ 50,000 hours = 70%, Ta = 50⁰C, in built surge protection of 4kV (in Differential and Common mode), Power Factor > 0.95, Colour Rendering Index > 70 and Cool white light (5700⁰K). Warranty: 5 year.
Supply,installation,testing and commissioning of 15kVA/12 KW three phase Diesel Generator set with standered control panel,radiator cooled diesel engine developing 23 BHP at 1500 rpm with CPCBII approved acoustic enclousure and standard accessories coupled to brushless self excited Alternator rated 12 KW/15 KVA at 415 volts conforing to IS/IEC 60034-1mounted on Channel Iron Base Frame complete with in built Fuel Tank of 62 Ltrs capacity facory assembled and fixed with all test certifications (Prefe rred make: Engine CUMMINS, KIRLOSKAR,CATERPILLER; Alternator : BHEL EML, KIRLOSKAR, STAMFORD including transportation, unloading,leading to the plinth ,and erection at site
Supply and providing First Aid Chart duty framed and placed in a conspicuous location for clear vision
Supply and providing 9 litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint "FIRE" mounted on MS angle frame work/wall bracket fillled with fine sand, painting the frame work/floor stand including making good the damages, colour washing etc.as required.
Supply and providing 6 mm thick & 1 m wide electrical grade chequered type rubber mat to withstand 3.3 KV dielectric strength conforming to IS 15652/2006
Supply and providing 6Kg stored pressure ABC Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required.
Supply and installation of wall mounting cubicle type dust and vermin proof size 4 , 600x300x214 mm, Mi 9410 Hensel make thermoplastic box including supply and fixing 63A,415V,50HZ,AC 23A duty,4pole ON LOAD CHANGE OVER SWITCH-1No,Panel surface mounting 96 Sq.mm LED Multi-function meter with three line display to read V,A,,kVA,kVAr,PF,KW and frequency of make Schnider or equivalent suitable for 415V,50Hz with RS 485 communication port - 2Nos, 2A single pole MCB (C curve) - 6 Nos, 30/5 A Tape wound CT-3Nos,32A two way disconnectable type neutral link-2 Nos,16mm dia Phase indication lamp-Red and Yellow-2 Nos,Blue-1No including giving connection using 10.0 sq.mm pvc insulated copper wire.
Supply and providing single line diagram duly framed,laminated and placed in a conspicuous location for clear vision
Charges for preparing documents, schematic diagram for obtaining sanction for energisation from kerala state electrical inspectorate and KSEB
First fill of diesel
Exhaust piping with MS Class B pipe of 50mm dia, heavy duty bend and flexible connector, MS support etc.including 2 coat heat resistant painting.
Making thermal insulation on exhaust piping (using glass wool & Aluminium cladding)
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required.
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_619858.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .