Supply, Installation, Testing, Commissioning and One Year Operation and Maintenance of Power Transformer along with Allied Electrical Equipments of 11 KV Electrical Power Distribution Sub-station for the 124 MLD capacity WTPs and CWPS...
2019_KMDA_259684_1
SE (E/M)-I/3T-01/2017/397
Open Tender
Electrical Work/ Equipment
Item Rate
300 days
Sonarpur.
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹4 L
OFFICE OF THE SUPERINTENDING ENGINEER (E/M)-I
20 Mar 2020
14 Dec 2019
13 Jan 2020
14 Dec 2019
11 Jan 2020
16 Dec 2019
20 Dec 2019
Amount
PART – A ( SUPPLY PART )
Supply, delivery at site and storage of 1500 KVA, 11 KV / 433 V ONAN indoor type Transformers with neutral brought out as per technical specification and all accessories complete
Supply, delivery at site and storage of 4 panel, 350 MVA indoor type H.T. Vacuum Circuit Breaker as per specification with all inter connection
Supply, delivery at site and storage of multi panel 2500 A MV Switch board connected with the secondary side of 1500 KVA transformers suitable for operation at 415 volt, 3 phase, 50 Hz AC system with all interconnection complete as per specification
Supply, delivery at site and storage of 110 V, 100Ah, sealed maintenance free battery comprising of 55 nos., 2 Volts cells with float and boost charger cum DCDB
Supply, Delivery at site and storage of 440V, 240 KVAR, 12 stage automatic power factor improvement capacitor bank ( APFC ) with all inter connection complete suitable for 415 V, 50 Hz system as per specification
Supply, delivery at site and storage of H.T., M.V. & Control Cable as per specification & as follows
i) H.T. Cable
From WBSEDCL’s summation panel to incoming panel of HT Switch gear of 11 KV grade, 300 sq mm dia, Al conductor, XLPE insulated, armoured cable as per specification
From HT Switchgear to two numbers of 1500 KVA Transformer HV side terminal of 11 KV grade, 300 sq mm dia, Al conductor, XLPE insulated, armoured cable as per specification
M.V. Cables / Bus Duct
From two numbers of 1500 KVA transformer secondary side to the two number of 2500A incomers of MV Switchboard, Bus Duct & accessories with adequate size of Aluminium conductor complete with sealing as per specification & direction of E.I.C.
From each of the 1600 A outgoing ACB of 2500 A Substation MV Switchboard to respective incoming ACB of M.V. Panel at Treatment Plant i.e. MCC-I, 1.1 KV grade, 3.5 C, 300 sq mm, Al. conductor, XLPE insulated armoured cable, 5 lengths.
From each of the 1000 A outgoing ACB of 2500 A Substation MV Switchboard to respective incoming ACB of M.V. Panel at Treatment Plant i.e. MCC-2, 1.1 KV grade, 3.5 C, 300 sq mm, Al. conductor, XLPE insulated armoured cable, 3 lengths.
From 2500 A Substation MV Switch Board to Battery Charger, 1.1 KV grade, 4 C x 6 sq mm stranded Cu conductor, XLPE insulated armoured cable.
From Battery Charger / DCDB to H.T. Panel at Sub Station, 1.1 KV grade, 3 C X 2.5 sq mm stranded Cu. Conductor, XLPE insulated armoured cable.
From 2500 A Sub-station MV Switch Board to ventilation system, 1.1 KV grade, 4 C x 6 sq mm stranded Cu. Conductor, XLPE insulated armoured cable.
From 2500 A Substation MV Switch Board to Lighting DB, 1.1 KV grade 4 C x 6 sq mm stranded Cu. Conductor, XLPE insulated armoured cable.
From 2500 A Substation MV Switch Board to HT Switchgear, 1.1 KV grade 3 C x 2.5 sq mm stranded Cu. Conductor, XLPE insulated armoured cable.
Control Cable
Stranded copper conductor of various ratings and of suitable sizes as per specification for all control circuit and interlocking circuits at Substation
Supply, delivery at site and storage of Jointing Materials as per specification & as follows:
All H.T Cables jointing materials ( Dry type, Heat Shrink Joint )
All MV Cables jointing materials for different Cross sections ( Dry type )
All copper control & power Cables jointing materials for different cross sections ( Dry type )
N.B :- No extra payment would be made if the length and diameter of the different sizes of cable & joints varies on the higher side to meet up the requirement of the specification and site condition. Rates must be quoted carefully. This is also applicable for all type of cable joints.
Supply & delivery at site and storage of earthing equipment as per specification and all the other equipments required to comply with latest I.E. Rules
Supply, delivery at site and storage of fire extinguishers as follows:
A-B-C Type ( 5 Kg each )
CO2 Type ( 4.5 Kg each )
Supply & delivery at site and storage of Misc. items such as rubber mats, Shock Treatment Chart, danger boards, sand buckets, Glow sign board etc. as per specification.
Supply & delivery at site and storage of all luminaries, fittings, and fixtures complete with necessary multi-strand copper wires for inside lighting of Substation as per specification.
Supply & delivery at site and storage of Lightning arrestor along with earth strip and earth electrodes all complete as per specification and all other equipment required to comply with latest I.E. Rules.
Supply & delivery at site and storage of spare parts as per specification.
PART – B ( INSTALLATION PART )
Installation at site of 1500 KVA, 11 KV / 433 V ONAN indoor type Transformers with neutral brought out as per technical specification and all accessories complete
Installation at site of 4 panel, 350 MVA indoor type H.T. Vacuum Circuit Breaker as per specification with all inter connection
Installation at site of multi panel 2500 A MV Switch board connected with the secondary side of 1500 KVA transformers suitable for operation at 415 volt, 3 phase, 50 Hz AC system with all interconnection complete as per specification
Installation at site of 110 V, 100Ah, sealed maintenance free battery comprising of 55 nos., 2 Volts cells with float and boost charger cum DCDB
Installation at site of 440V, 240 KVAR, 12 stage automatic power factor improvement capacitor bank ( APFC ) with all inter connection complete suitable for 415 V, 50 Hz system as per specification
Installation / Laying at site of H.T., M.V. & Control Cable as per specification & as follows
i) H.T. Cable
From WBSEDCL’s summation panel to incoming panel of HT Switch gear of 11 KV grade, 300 sq mm dia, Al conductor, XLPE insulated, armoured cable as per specification
From HT Switchgear to two numbers of 1500 KVA Transformer HV side terminal of 11 KV grade, 300 sq mm dia, Al conductor, XLPE insulated, armoured cable as per specification
M.V. Cables / Bus Duct
From two numbers of 1500 KVA transformer secondary side to the two number of 2500A incomers of MV Switchboard, Bus Duct & accessories with adequate size of Aluminium conductor complete with sealing as per specification & direction of E.I.C.
From each of the 1600 A outgoing ACB of 2500 A Substation MV Switchboard to respective incoming ACB of M.V. Panel at Treatment Plant i.e. MCC-I, 1.1 KV grade, 3.5 C, 300 sq mm, Al. conductor, XLPE insulated armoured cable, 5 lengths.
From each of the 1000 A outgoing ACB of 2500 A Substation MV Switchboard to respective incoming ACB of M.V. Panel at Treatment Plant i.e. MCC-2, 1.1 KV grade, 3.5 C, 300 sq mm, Al. conductor, XLPE insulated armoured cable, 3 lengths.
From 2500 A Substation MV Switch Board to Battery Charger, 1.1 KV grade, 4 C x 6 sq mm stranded Cu conductor, XLPE insulated armoured cable.
From Battery Charger / DCDB to H.T. Panel at Sub Station, 1.1 KV grade, 3 C X 2.5 sq mm stranded Cu. Conductor, XLPE insulated armoured cable.
From 2500 A Sub-station MV Switch Board to ventilation system, 1.1 KV grade, 4 C x 6 sq mm stranded Cu. Conductor, XLPE insulated armoured cable.
From 2500 A Substation MV Switch Board to Lighting DB, 1.1 KV grade 4 C x 6 sq mm stranded Cu. Conductor, XLPE insulated armoured cable.
From 2500 A Substation MV Switch Board to HT Switchgear, 1.1 KV grade 3 C x 2.5 sq mm stranded Cu. Conductor, XLPE insulated armoured cable.
Control Cable
Stranded copper conductor of various ratings and of suitable sizes as per specification for all control circuit and interlocking circuits at Substation
Installation at site of Jointing Materials as per specification & as follows:
All H.T Cables jointing materials ( Dry type, Heat Shrink Joint )
All MV Cables jointing materials for different Cross sections ( Dry type )
All copper control & power Cables jointing materials for different cross sections ( Dry type )
N.B :- No extra payment would be made if the length and diameter of the different sizes of cable & joints varies on the higher side to meet up the requirement of the specification and site condition. Rates must be quoted carefully. This is also applicable for all type of cable joints.
Installation at site of earthing equipment as per specification and all the other equipments required to comply with latest I.E. Rules
Installation at site of fire extinguishers as follows:
A-B-C Type ( 5 Kg each )
CO2 Type ( 4.5 Kg each )
Installation at site of Misc. items such as rubber mats, Shock Treatment Chart, danger boards, sand buckets, Glow sign board etc. as per specification.
Installation at site of all luminaries, fittings, and fixtures complete with necessary multi-strand copper wires for inside lighting of Substation as per specification.
Installation at site of Lightning arrestor along with earth strip and earth electrodes all complete as per specification and all other equipment required to comply with latest I.E. Rules.
Carrying out heat run of HT & MV equipments, dehydration of Transformer oil and making ready all HT / MV equipment for High / Medium pressure testing as per rule
Carrying out statutory high pressure testing on all HT equipment & medium pressure testing on MV equipments as per specification including charges of Govt. Inspector
Charges for Diesel Generator set / Temporary power connection from WBSEDCL / CESC for construction purposes
Testing the whole installation & submission of test reports as per specification & direction of EIC
Commissioning the whole installation including trial run for 72 hours on load operation as per specification & direction of EIC
Operation & maintenance of all electrical appliances installed in the substation for a period of one year with adequate number of working personnel for round the clock operation as per requirement and as per specification & direction of EIC
POWER INDIA
G B CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .