| 1 | L1₹39.0 LAccepted-AOC PLOT NO 3 DIVINE SCHOOL ROAD NEAR BJP KARYALAY PORBANDAR KHAMBHALIYA HIGHWAY BOKHIRA PORBANDAR 360 579 | PORBANDAR | GUJARAT | 360579 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹47.0 L+₹5.0 L (11.9%)Rejected-Finance PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹47.0 L+₹5.1 L (12.2%)Rejected-Finance HQ CWE AHMEDABAD | GANDHINAGAR | GUJARAT | 382006 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹49.9 L+₹8.0 L (19.0%)Rejected-Finance 3 SHITALNATH FLATE 1 NR KHANPUR JAIN TEMPLE OPP BANK OF INDIA SHAHPUR AHMEDABAD GUJARAT 380001 | AHMADABAD | GUJARAT | 380001 | L4 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
7 Aug 2021, 6:00 pmClosed
Maj Yogender Singh
GE Navy Porbandar Tija Mile Porbandar
CERTAIN REPAIRS, MAINTENANCE OF ELECTRICAL WIRING, FITTINGS, FIXTURES, SUBMAIN WIRING AND MAINT, REPAIR OF COOLING APPLIANCES INCLUDING ALLIED WORKS AT INS SARDAR PATEL AND NAE UNDER GE NAVY PORBANDAR
2021_MES_455726_1
9073/PBR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹90,000
Yes
20 Aug 2021
29 Jun 2021
9 Aug 2021
29 Jun 2021
7 Aug 2021
14 Jul 2021
30 Jun 2021 - 13 Jul 2021
Amount
Repair of Cooling Appliances:-
Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the window type air conditioner of 1.5 Ton capacity complete all as specified and directed.
All as per description of item No. 1.00 here-in-before but cassette type 2.0 Ton capacity complete all as specified and directed.
All as per description of item No. 1.00 here-in-before but cassette type 3.0 Ton capacity complete all as specified and directed.
All as per description of item No. 1.00 here-in-before but split type AC 1.5 Ton capacity complete all as specified and directed.
All as per description of item No. 1.00 here-in-before but split type AC 2.0 Ton capacity complete all as specified and directed.
All as per description of item No. 1.00 here-in-before but water cooler 40/60/80 ltrs cooling capacity complete all as specified and directed.
All as per description of item No. 1.00 here-in-before but water cooler 120/150 ltrs cooling capacity complete all as specified and directed.
All as per description of item No. 1.00 here-in-before but refrigerator 190/240 ltrs capacity complete all as specified and directed.
All as per description of item No. 1.00 here-in-before but refrigerator 292/340 ltrs capacity complete all as specified and directed.
All as per description of item No. 1.00 here-in-before but deep frezzer 320 ltrs capacity complete all as specified and directed.
Material and labour for taking out window type Air conditioner 1.5 Ton capacity of any make from its original location, removing the dust from body with blower, cleaning the condenser and cooling coil using water and caustic soda solution and checking all connections including functioning of metal clad socket/ DP switch function of relay capacitors overload protector thermostat fan motor blade fan blower drum oiling / greasing of fan motor, refixing to its original location including testing making it fully functional complete all as specified & directed by Engineer-in-Charge.
Material & labour for servicing the split AC's of various capacities i.e. 1.00/1.50/2.00 Tonne by removing dust with blower, cleaning the outer & inner unit using water and solution, checking all connections and spares making the split AC fully functional complete all as specified & directed by Engineer-in-Charge. Note for item No. 11 & 12: (a) The cost of Minor consumeables is deemed to be included in the quoted rate. (b) Refrigerant gas if required will be measured & paid separately.
M&L for Shifting of split AC from existing location to new location including making good of old location and fixing, connecting and testing split type room air conditioner with wall mounted indoor unit, outdoor (condensing) unit including provision of copper tube, refrigerant topup and return piping of appropriate size duly insulated, condensated water outlet pipe and 3 core copper wire from upto plug / socket complete all as specified & directed by Engineer-in-Charge.
Material and labour for providing body base tray made of 18 SWG MS galvanized sheet of suitable size for window type air conditioners including motor mounting frame nuts and bolts duly painted with synthetic enamel paint and necessary insulation complete for 1.5 ton capacity Air conditioner complete all as specified & directed by Engineer-in-Charge. (Note : Dismantling of compressor for body work and reassembling as per site requirement shall be inclusive in quoted rate).
Material and labour for preparation of old painted surfaces of Refrigerator any capacity by complete scraping old painting an applying two coats of Hi gloss synthetic enamel paint on outer surface (spray painting) as per existing colour and black colour on bottom portion such as compressor complete all as specified & directed by Engineer-in-Charge.
Material and labour for preparation of old painted surfaces of Water cooler any capacity by complete scraping old painting an applying two coats of Hi gloss synthetic enamel painting on outer surface (spray painting) as per existing colour and black colour on bottom portion such as compressor complete all as specified & directed by Engineer-in-Charge.
Supply, install, test & commissioning new compressor sealed reciprocating type suitable for window type AC 1.5 Ton capacity duly charged with fresh Refrigerant gas complete all as specified & directed by Engineer-in-Charge.
All as per description of item No. 17.00 here-in-before but suitable for cassette type 2.0 Ton capacity AC complete all as specified and directed.
All as per description of item No. 17.00 here-in-before but suitable for split type 1.5 Ton capacity AC complete all as specified and directed.
All as per description of item No. 17.00 here-in-before but suitable for split type 2.0 Ton AC capacity complete all as specified and directed.
All as per description of item No. 17.00 here-in-before but suitable for cassette type 3.0 Ton capacity AC complete all as specified and directed.
All as per description of item No. 17.00 here-in-before but suitable for refrigirator 190/240 ltrs capacity complete all as specified and directed.
All as per description of item No. 17.00 here-in-before but suitable for refrigirator 292/340 ltrs capacity complete all as specified and directed.
All as per description of item No. 17.00 here-in-before but suitable for water cooler 40/60/80 ltrs cooling capacity complete all as specified and directed.
All as per description of item No. 17.00 here-in-before but suitable for water cooler 150 ltrs cooling capacity complete all as specified and directed.
All as per description of item No. 17.00 here-in-before but suitable for deep freezers 320 ltrs capacity complete all as specified and directed.
Removing the existing unserviceable burnt fan motor from window / split type AC of capacity 1.5 / 2 Ton and replacing the same with brand new fan motor of same capacity including connecting up and testing complete all as specified and directed.
Supply and fix fan motor suitable for water cooler of any capacity including removing old fan motor and testing complete all as specified and directed.
Supply and fixing fan blade suitable for window/split type Air conditioner of 1.5 / 2.0 Ton capacity including removing old fan blade complete all as specified and directed.
Supply and fixing fan blade suitable for water cooler of any capacity including removing old fan blade complete all as specified and directed.
S & F blower drum suitable for window type Air conditioner of 1.5 Ton / 2.0 Ton capacity including taking down old blower complete all as specified and directed.
S & F Blower motor suitable for split type Air conditioner of 1.5 Ton / 2.0 Ton capacity including taking down old motor complete all as specified and directed.
S & F defective Swing motor and supply & fix Swing motor suitable for split type Air conditioner of 1.5 Ton / 2.0 Ton capacity including taking down old motor complete all as specified and directed.
S & F Front cover grill suitable for window type AC 1.0 Ton / 1.5 Ton / 2.0 Ton capacity AC, including taking down old grill, complete all as specified and directed.
S & F starting capacitor 60 - 80 mfd including taking down old capacitor complete all as specified and directed.
S & F starting capacitor 80 -100 mfd including tking down old capacitor complete all as specified and directed.
S & F starting capacitor 100 - 120 mfd including tking down old capacitor complete all as specified and directed.
S & F running capacitor 25 MFD including tking down old capacitor complete all as specified and directed.
S & F running capacitor 36 MFD including tking down old capacitor complete all as specified and directed.
S & F running capacitor 45 MFD including tking down old capacitor complete all as specified and directed.
All as per description of above item No. 41.00 here-in-before but rotary type complete all as specified and directed.
Supply and fix thermostat switch for window type AC of 1.5 Ton capacity fixed in repair complete all as specified and directed.
Supply and fix thermostat switch for split type AC of 1.5 / 2.0 Ton capacity in fixed in repair / replacement complete all as specified and directed.
Supply and fix thermostat switch for refrigerator of any capacity in fixed in repair / replacement complete all as specified and directed.
Supply and fix thermostat switch for water cooler of any capacity in fixed in repair / replacement complete all as specified and directed.
Supply & Fix new over load relay suitable for Window type AC of 1.5 Ton capacity including taking down old over load relay complete all as specified and directed.
Taking out old unserviceable and Supply & Fix new over load relay suitable for water cooler of any capacity complete all as specified and directed.
Taking out old unserviceable and Supply & Fix new over load relay suitable for refregerator of any capacity complete all as specified and directed.
Supply and fix of Float valve suitable for Water cooler of any capacity complete all as specified and directed.
Supply fixing and clamping jointing copper tubing for suction line and for liquid discharge line duly insulated with suitable insulation material including making hole in wall for passing through and making good to the disturbed surface complete all as specified and directed.
Supply and lay cable PVC insulated 3 core 4 Sq mm with copper conductor cable suitable for indoor unit to outdoor unit complete all as specified and directed.
Supply and lay PVC pipe 20 mm dia heavy duty for drain out condensing water of split AC including cutting of floor / opening of hole in wall and making good after laying of pipe etc match the existing surface complete all as specified and directed.
Supply and fix push cock / lifting cock of 15 mm bore in repair for water cooler of any capacity complete all as specified and directed.
Supply and fix PVC connecting pipe with brass nuts and washers at both ends of length not exceeding 60 cms for connection of water coolers complete all as specified and directed.
Supply and fix GI water tray 2 mm thick for window type AC any capacity with out let system connection provided with PVC pipe of 20 mm dia up to 3 meter length connecting to drain pipe complete all as specified and directed.
Supply and fix PVC drain pipe with necessary saddles of 25 mm size to be used as out let drain to be fixed complete all as specified and directed.
Supply and fix sheet metal enclosure with 2 pin and earth plug and socket complete with single pole MCB of 20 Amps complete all as specified and directed.
Supply & fix new magnetic gasket for refrigerator of 190/240/292/340 liters including taking down old gasket of both door and main body complete all as specified and directed.
Supply, Fixing and Testing Condenser coil of 1.5 Ton window type AC any make with fins cutting in let outlet connecting copper pipe and providing new condensor coil with fins and connecting inlet outlet copper pipe by brazing and replacement of nut bolts including taking out old coil complete all as specified and directed.
All as per description of item No. 60.00 here-in-before but 1.5 ton split type AC complete all as specified and directed.
All as per description of item No. 60.00 here-in-before but 2.0 ton split type AC complete all as specified and directed.
S & F circuit boards from window type AC 1.5 ton capacity and connecting with system with replacing remote control hand set and testing including taking down old circuit board complete all as specified and directed.
All as per description of item No. 63.00 here-in-before but 1.5 ton / 2.0 ton split type AC complete all as specified and directed.
Supply and fix blower fan motor capacitor 4 MFD including taking out old capacitor complete all as specified and directed.
Supply and fix blower fan motor capacitor 6 MFD including taking out old capacitor complete all as specified and directed.
Supply and fix of electric bulb suitable for refrigerator of any capacity screw type / pin type including taking out old bulb complete all as specified and directed.
Supply and fix of Air filter for window type AC of any capacity and type including taking out old filter complete all as specified and directed.
Material and labour for providing outer cover for window type Air conditioner of any shape & size made out of galvanized sheet 20SWG complete all as specified and directed.
Supply & fix new over load protector for 1.5 /2.0 Ton capacity window type Air Conditioner including taking out old over load protector complete all as specified and directed.
Supply and fix multipurpose door lock with duplicate key of refrigerator of any make & capacity fixed in repair / replacement complete all as specified and directed.
S & F cooling coil of window/split type AC any capacity and any make cutting inlet outlet connecting inlet outlet pipe by brazing, securing and replacement of nut bolts including testing & taking down old coil complete all as specified and directed.
Supply and fix wiring kit for AC of capacity 1.5/2.0 ton AC fixed in repair / replacement complete all as specified and directed.
Supply and fix foam type insulating flexible hollow tube for suction and discharge tubes of 1.5/2 Ton capacity split AC fixed in repair / replacement complete all as specified and directed.
Cutting of existing wall / window grills / frame for making suitable space to accomodate window AC making frame with 2 nd class hard wood piece of min of 50 X 50 mm size and up to 60 cm height for fixing of outer cover of AC and supporting structure made out 40 mm X 40 mm X 5 mm thick MS angle iron dully grouted in wall and closing the open space around ACs with the help of 6 mm thick ply wood exterior grade to close air leakage tightening with green felt and painting to wooden surfaces matching to interiors as directed and steel structure with one coat of primer and two coats of synthetic enamelled paint and fixing only window type AC complete connecting and testing all as specified and directed.
Supply & fix furnace contactor 24 V AC,2 pole,30 Amps of split ac 1.5/2 type & capacity fixed in repair / replacement complete all as specified and directed.
S & F filter catridge suitable upto 8-25 ltrs RO Plant including taking out old filter complete all as specified and directed.
S & F carbon filter catridge suitable upto 8-25 ltrs RO Plant including taking out old cartridge complete all as specified and directed.
S & F filter catridge suitable upto 25- 50 ltrs RO Plant including taking out old cartridge complete all as specified and directed.
S & F membrane for reverse osmosis of upto 25 Ltrs for RO Plant including taking out old membrane complete all as specified and directed.
M&L for Diaphragm pump, 24V DC,Rated Current 2.6 Amp,inlet pressure 30 Psi including taking out old pump complete all as specified and directed.
M&L for SMPS adaptor ,230 V AC,50 Hz,24 V DC,3 Amp including taking out old SMPS adaptor complete all as specified and directed.
M&L flow restrictor suitable for RO Plant 25 ltrs capacity including taking out old valve complete all as specified and directed.
M&L solenoid valve,24V AC,0-0.7 Mpa suitable for RO Plant 25 ltrs capacity including taking out old valve complete all as specified and directed.
S&L Tube Roll of size 1x 1/4 " Suitable for RO Plant upto 25 Ltrs Capacity complete all as specified and directed.
S&L Tube Jointer of size 1x 1/4 " Suitable for RO Plant upto 25 Ltrs Capacity complete all as specified and directed.
Taking down aluminium point wiring (light, fan, buzzer, socket or power & AC Points) complete, including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets, etc. removing materials to store for keeping safe custody or for taking credit and making good disturbed surfaces of walls, floors etc as per existing all as Specified and directed by Engr-in-Charge
Repair Maintenance of Electrical fitting, fixtures and allied items:-
Taking down sub main wiring of aluminium conductor PVC insulated cable of any size drawn through rigid steel / PVC conduit GI wire accessories etc complete and removing materials from site except those which are found serviceable kept in safe custody for reuse in the work all as Specified and directed by Engr-in-Charge.
Point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for the following :-
One light point controlled by one one way switch
One fan/ exhaust fan point controlled by one way switch
One buzzer point controlled by one way switch
One 5 Amps 3/5 pin socket outlet on same board with other switches.
One 5 Amps 3/6 pin socket outlet on independent board
One light point controlled by two Nos two way switches
All as per item No. 89 hereinbefore but with using 2.5 sq mm PVC insulated multi-stranded copper conductor FRLS cable for independent switch socket outlet 6 pin 5/15 Amps and incl 1.5 sqmm PVC insulated multi-stranded FRLS copper conductor single core as earth continuity conductor wire duly connected to all common earth point, drawn through and including 20 mm dia PVC surface conduit in any length all as directed at site complete all as specified and directed.
All as per item No. 89 hereinbefore but Point 4 sq mm PVC insulated multi-stranded copper conductor FRLS cable for industrial socket outlet 3 pin 16 Amps point and one single core 2.5 sq mm PVC insulated FRLS unsheathed copper cable as earth continuity conductor (colour green) fixed to dolly complete all as specified and directed.
S & F Switch piano flush type 5/6 Amps single pole one way 230 Volts complete all as specified and directed.
S & F Switch piano flush type 15/16 A single pole one way 230 V fixed complete all as specified and directed.
S & F Socket Outlet 2 in 1, 3 pin 5 Amps flush type 230 Volts fixed complete all as specified and directed.
S & F Socket Outlet 2 in 1 3/6 pin 5and15 Amp flush type 230 V fixed complete all as specified and directed.
S & F Switch piano flush type, 6 amps two way,SP,230 volts AC fixed complete all as specified and directed.
S & F Bell push, flush type 5 Amps 230 Volts complete all as specified and directed.
S & F Stepped modular type electronic fan regulator flush type for 1200 /1400 mm sweep fans complete all as specified and directed.
S & F Modular switch 6 Amps, two way, one module 240 volts,50 Hz fixed complete all as specified and directed.
S & F Modular blank plate, two module 240 volts,50 Hz complete all as specified and directed.
S & F Modular blank plate, three module 240 volts,50 Hz complete all as specified and directed.
S & F Fan step regulator, rotary type, 120 W, modular hum free AC 230 volts,2 module duly ISI marked complete all as specified and directed.
S & F Bell, AC, 230 volts, single pole, ding dong type fixed on and including 03 mm thick plastic laminated sheet cover of suitable size with brass screws and washers etc complete all as specified and directed.
S & F Ceiling rose surface bakelite, 65x50mm 3 terminals complete all as specified and directed.
M & L for Sub main wiring concealed with 2.5Sqmm (Nominal area) two runs of single core cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, confirm to IS with copper conductor drawn into rigid non-metallic PVC concealed conduit complete including 2.5 sqmm (nominal area) single core PVC insulated multistrand unsheathed copper conductor cable FRLS as earth wire and duly connected to all common earth point complete all as specified and directed by Engr-in-Charge.
M & L for Sub main wiring concealed with 4Sqmm (Nominal area) two runs of single core cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, confirm to IS with copper conductor drawn into rigid non-metallic PVC concealed conduit complete including 4 sqmm (nominal area) single core PVC insulated multistrand unsheathed copper conductor cable FRLS as earth wire and duly connected to all common earth point complete all as specified and directed by Engr-in-Charge.
M & L for Sub main wiring concealed with 6Sqmm (Nominal area) two runs of single core cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, confirm to IS with copper conductor drawn into rigid non-metallic PVC concealed conduit complete including 6 sqmm (nominal area) single core PVC insulated multistrand unsheathed copper conductor cable FRLS as earth wire and duly connected to all common earth point complete all as specified and directed by Engr-in-Charge.
M & L for Sub main wiring concealed with 10Sqmm (Nominal area) two runs of single core cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, confirm to IS with copper conductor drawn into rigid non-metallic PVC concealed conduit complete including 10 sqmm (nominal area) single core PVC insulated multistrand unsheathed copper conductor cable FRLS as earth wire and duly connected to all common earth point complete all as specified and directed by Engr-in-Charge. Note for item No. 105.00 to 108.00 :- Cable to be drawn in existing pipe, whereever new pipe directed to be provided, Rigid non metalic conduit and cutting chasing will be measured and paid seprately.
M & L for 15mm Rigid non metalic conduit concealed in wall including all cutting chasing and making good complete all as specified and directed by Engr-in-Charge.
S & F Sheet metal enclosure DB ,Single pole and neutral with 200 Amps rated bus bar,230 volts double door type including connecting all connections of wire to MCBs with proper lugs & arrangements, making good to the disturbed surface after taking down existing DB complete all as specified and directed.
DB 4 way
DB 8 way
DB 12 way
S & F Loadline distribution box 4 way, AC, TP & neutral metal enclosure, double door, 415V AC, concealed type with suitable bus bar, neutral link, earth link suitable for MCCB, 100Amps as incomer and MCB,SP as out going after taking down existing DB fixed in repair / replacement complete all as specified and directed.
S & F Loadline distribution box 8 way, AC, TP & neutral metal enclosure, double door, 415V AC, concealed type with IP-43 protection complete with suitable bus bar, neutral link, earth link suitable for MCCB 125/150Amps as incomer and MCB, SP as out going after taking down existing DB fixed in repair / replacement complete all as specified and directed.
S & F MCCB, 3pole, 415 volt AC, 100 amps, fixed type with breaking capacity 16KA fixed in repair / replacement complete all as specified and directed.
S & F MCCB, 3pole, 415 volt AC, 125 amps, fixed type with breaking capacity 16KA fixed in repair / replacement complete all as specified and directed.
S & F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings for LED Lamp complete all as specified and directed.
S & F Street light fitting bracket, 1.5 mtr long made of galvanized iron pipe of 40 mm bore light grade complete with nut, bolts, washer etc inclusive of one primer coat, one under coat and one finishing coat of silver paint fixed in repair / replacement complete all as specified and directed.
S & F Street light fitting bracket, 2.5 mtr long made of galvanized iron pipe of 40 mm bore light grade complete with nut, bolts, washer etc inclusive of one primer coat, one under coat and one finishing coat of silver paint fixed in repair / replacement complete all as specified and directed.
Taking down of ceiling fan 1200/1400mm sweep of any type and make from ceiling and Overhauling by removing of old grease from bearing of ceiling fan and re-filling new grease including replacement of worn out nut bolt / washer, rubber real bush MS Nut bolts with split pin and rubber bush, canopy and reassembling the fan complete after one coat of white enamel paint and hanging on its original / new position and testing for performance complete all as specified and directed. Note : Ball bearing and Gun metal bush ,capacitor (if reqd) will be paid and measured separately.
Taking down of exhaust fan / wall mounted fan of any type and capacity from position and Overhauling of cleaning and removing of old grease from bearing of ceiling fan and re-filling new grease including replacement of worn out nut bolt / washer, rubber real bush MS Nut bolts with split pin and rubber bush, and reassembling the fan complete after one coat of white enamel paint and hanging on its original / new position and testing for performance complete all as specified and directed. Note : Ball bearing and Gun metal bush ,capacitor (if reqd) will be paid and measured separately.
Taking down of ceiling fan 1200/1400mm sweep of any type and make from ceiling and rewinding the same by opening the body cover, removing old/burnt winding cleaning of slots/ pitches by using any cleaning material by removing iron & carbon dust etc and rewinding the fans with appropriate size of super enamelled copper wire with correct number of turns of auxiliary and main winding and varnishing and backing, soldering new lead of copper wire , duly varnished, dry the winding for adequate period to remove the moisture contents and strengthening the winding and testing , and hanging on its original / new position with MS nut bolts with spilt pin, rubber reel, complete all as specified and directed. Complete all as specified and as directed. Note : Ball bearing and Gun metal bush ,capacitor if required will be paid and measured separately.
Taking down of Exhaust fan / wall mounted fan of any type and make from its existing position and rewinding the same by opening the body cover, removing old/burnt winding cleaning of slots/ pitches by using any cleaning material by removing iron & carbon dust etc and rewinding the fans with appropriate size of super enamelled copper wire with correct number of turns of auxiliary and main winding and varnishing and backing, soldering new lead of copper wire , duly varnished, dry the winding for adequate period to remove the moisture contents and strengthening the winding and testing , and hanging on its original / new position with MS nut bolts with spilt pin, rubber piece, complete all as specified and directed,complete all as specified and as directed. Note : Ball bearing and Gun metal bush ,capacitor if required will be paid and measured separately.
S & F Gun metal bush of any type and size suitable for ceiling fan/ exhaust fan/ Wall fans fixed in repair / replacement complete all as specified and directed.
S & F Ball bearing for Ceiling fan 1200mm / 1400mm sweep fixed in repair / replacement complete all as specified and directed.
S & F Ball bearing for Exhaust fan 230mm / 300 mm/450 mm sweep fixed in repair / replacement complete all as specified and directed.
S & F Ball bearing for Wall mounted fan 380mm / 450mm sweep fixed in repair / replacement complete all as specified and directed.
S & F Capacitor, 230 volts, AC + 5% 2.5 mfd fixed in repair / replacement complete all as specified and directed.
S & F Capacitor, 230 volts, AC + 5% 3.15 mfd fixed in repair / replacement complete all as specified and directed.
S & F Capacitor, 230 volts, AC + 5% 4 mfd fixed in repair / replacement complete all as specified and directed.
M & L for Opening the geyser 25/50 Ltr capacity and taking out inner tank and glass wool from inside the geyser for descaling and washing with acid to remove the scale, dirt etc if any and re-fixing the same after re-assemble into the geyser and proper filling of glass wool around inner tank complete all as specified and directed. Note :-Glass wool will be paid separately under respective item of BOQ as 'supply only'.
Supply only pack glass wool for geyser & solar water heater complete all as specified and directed by Engineer-in-Charge.
S & F Outer tank made out of MS sheet suitable for geyser of capacity 25 Ltr as per sample duly painted with two coats of synthetic enamel paint over a coat of red oxide primer fixed in repair / replacement complete all as specified and directed.
S & F Inner tank made out of steel sheet suitable for geyser of capacity 25 Ltr complete including necessary drilling, brazing work, nut, bolt & washers and testing fixed in repair / replacement complete all as specified and directed.
S & F Plug top 3 pin 15 Amp 240 volts ISI marked fixed in repair complete all as specified and directed.
S & F Gun-metal, ball valve (disc type) screwed both ends for iron pipe, ISI marked of size 15mm bore, fixed in repairs ,complete all as specified and as directed.
S & F Non return valve (gun metal) of size 15mm, fixed in repairs, complete all as specified and directed.
S & F Fusible plug suitable for 25 Ltrs Cap storage type water heater including provn of necessary GI fittings including removal of existing valves complete all as specified and directed.
S & F Indicator lamp assembly complete for water heater (geyser) suitable to work on AC 230 volts supply and to match the existing size any type including disconnecting old lamp assembly complete all as specified and directed.
S & F Supply and fix only MS Nut bolts, washers with split pin as per sample suitable for ceiling fan complete all as specified and directed.
S & F Heating element 1.5 KW of storage type water heater of compatible type (ISI Marked) including making all connections by replacing inter connecting copper conductor cables and removal of old unserviceable elements fixed in repair / replacement complete all as specified and directed.
S & F Thermostat suitable for 25 ltrs capacity storage type water heater including removal of old unserviceable ones fixed in repair / replacement complete all as specified and directed.
S & F Outer cover plate lower suitable for 25 ltrs capacity geyser fixed in repair / replacement complete all as specified and directed.
S & F Geyser aperture plate/flange assembly (as per approved sample) of ISI marked suitable for 25 ltrs capacity geyser fixed in repair / replacement complete all as specified and directed.
S & F Wooden frame of suitable size and length for fixing of exhaust fan in existing hole including all nut/bolts complete all as specified and directed by Engineer-in-Charge.
S & F Pressure release valve suitable for 25 ltrs geyser fixed in repair / replacement complete all as specified and directed.
S & F Drain plug brass with washer suitable for 25 ltrs geysers fixed in repair / replacement complete all as specified and directed.
S & F PVC insulated standerd copper conductor 3 core flexible cable of size 40/0.0076 fixed in repair / replacement complete all as specified and directed.
M & L for Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI Strip 25x4mm by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 32mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover including testing on completion complete all as specified and directed.
M & L for Earthing continuity galvanised strip 25 x 4 mm or main earthing lead fixed to wall with clamps or recess or crosses or buried in ground or drawn in32mm dia bore light grade GI pipe or fixed to poles or any other indicated situation for loop earthing etc as required all as specified and directed by Engr-in-Charge.
S & F 600mm long Geyser hot water heavy duty PVC connecting made out of steel braded flexible pipe with brass female coupling for connecting geyser outlet to existing connecting point 15 mm dia fixed in repair / replacement complete all as specified and directed.
S & F 450mm long Geyser hot water heavy duty PVC connecting made out of steel braded flexible pipe with brass female coupling for connecting geyser outlet to existing connecting point 15 mm dia fixed in repair / replacement complete all as specified and directed.
M & L for Preparation of surface of LT pole i.e. scrapping by brushes, emery paper, caustic soda etc of LT pole 9m/11m long with all connected channel, cross arms caps etc painting one coat of aluminium paint over a coat of anti rusted paint as a primer on steel surfaces and One coat of primer and two coat of exterior acrylic emulsion paint (wheather coat) on Concrete surfaces including numbering by using white paint over a surface of black paint base of size 15cm x 15cm complete all as specified and as directed by Engineer-in-Charge. Note :- Manpower will be provided by contractor per pole per tradesman for scraping of pole for one shut down & for outer rust painting for pole for second shut down the period will only one hour per shut down in various period and timing and day which will be framed by the department.
S & F RCCB 25 Amp 100 mA, two pole, 240V, 50Hz, IP-20, protection against earth fault/leakge current conforming IS-12640-12000, IEC 61008-1, fixed in repairs, complete all as specified and as directed.
S & F RCCB 25 Amp 100 mA, four pole, 240V, 50Hz, IP-20, protection against earth fault/leakge current conforming IS-12640-12000, IEC 61008-1, fixed in repairs, complete all as specified and as directed.
Fixing only LED down light fitting suitable for fixing on wall & surface of capacity sqaure in shape complete with all electrical connection fixed in repair / replacement complete all as specified and directed. (Light fitting will be issued under Sch 'B' free for fixing).
M & L for Painting of Electric geyser of capacity 25 ltrs by applying two coats of high gloss synthetic enamel paint after scraping of old paint complete all as specified and as directed by Engineer-in-Charge.
M & L for Cable jointing kit for 11KV (Earthed) grade cable for Straight through joint heat shrinkable type complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 16 sqmm fixing complete all as specified and as directed.
M & L for Cable jointing kit for 11KV (Earthed) grade cable for Straight through joint heat shrinkable type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 to 50 sqmm fixing complete all as specified and as directed.
M & L for Cable jointing kit for 11KV (Earthed) grade cable for Straight through joint heat shrinkable type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 120 sqmm fixing complete all as specified and as directed.
M & L for Cable jointing kit for 11KV (Earthed) grade cable for Straight through joint heat shrinkable type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 150 to 185 sqmm fixing complete all as specified and as directed.
Laying, connecting and testing only LT UG Cable XLPE / PVC insulted wire armoured electric power cable with stranded aluminium conductor cross sectional area 16 sqmm 4 core suitable for working on 1100 Volts earthed system, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Laying, connecting and testing only LT UG Cable XLPE / PVC insulted wire armoured electric power cable with stranded aluminium conductor cross sectional area 25 sqmm 3.5 core suitable for working on 1100 Volts earthed system, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Laying, connecting and testing only LT UG Cable XLPE / PVC insulted wire armoured electric power cable with stranded aluminium conductor cross sectional area 35 sqmm 3.5 core suitable for working on 1100 Volts earthed system, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Laying, connecting and testing only LT UG Cable XLPE / PVC insulted wire armoured electric power cable with stranded aluminium conductor cross sectional area 50 sqmm 3.5 core suitable for working on 1100 Volts earthed system, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Laying, connecting and testing only LT UG Cable XLPE / PVC insulted wire armoured electric power cable with stranded aluminium conductor cross sectional area 70 sqmm 3.5 core suitable for working on 1100 Volts earthed system, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Laying, connecting and testing only LT UG Cable XLPE / PVC insulted wire armoured electric power cable with stranded aluminium conductor cross sectional area 95 sqmm 3.5 core suitable for working on 1100 Volts earthed system, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Laying, connecting and testing only LT UG Cable XLPE / PVC insulted wire armoured electric power cable with stranded aluminium conductor cross sectional area 120 sqmm 3.5 core suitable for working on 1100 Volts earthed system, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Laying, connecting and testing only LT UG Cable XLPE / PVC insulted wire armoured electric power cable with stranded aluminium conductor cross sectional area 240 sqmm 3.5 core suitable for working on 1100 Volts earthed system, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note For Item No 161 to167:- (a) Lt cable will be issued under Schedule B free for fixing . (b) Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe shall be measured and paid for separately.
Excavation in trenches in any type of soil n.exc 1.5 m wide and n.exc 1.5 m deep and getting out for taking out/laying of cable, GI pipe lines and foundation by manual means compete all as specified and as directed.
Returning, filling in trenches in soil incl spreading, levelling watering and ramming in layer n.exc 25 cm complete all as specified and directed.
Removing of excavated materials soil n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
M & L for Sand cushioning with a layer of sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed.
Supply and laying Unreinforced precast concrete cable cover, ISI marked class LV types 2 flat size 250mm x 150mm x 40mm having minimum average breaking load 200Kg, complying IS:5820-1970 made of concrete used of grade M-20, laid flat in trenches over the cable with the length of concrete cover perpendicular to the direction of the cable length, adjacent / abutting each other complete all as specified.
Supply, fixing and testing of LED Aviation lighting with aluminium housing and polycarbonate cover including taking down old light complete all as specified and directed. Make : Model No. BGAV 302 of Bajaj or equivalent model of make specified here-in-before.
K K Construction Co
roxy enterprise
SHREE CHAMUNDA ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .