| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-AOC | ₹28.3 L Quoted ₹28.8 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹29.7 L+₹93,896.60 (3.26%)Rejected-AOC | ₹29.7 L+₹93,896.60 (3.26%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹29.8 L+₹1.1 L (3.70%)Rejected-AOC | ₹29.8 L+₹1.1 L (3.70%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹30.0 L+₹1.2 L (4.13%)Rejected-AOC MUKALATH VALAYANCHIRANGARA PO PERUMBAVOOR ERNAKULAM KOCHI 683556 | PERUMBAVOOR | ERNAKULAM | KERALA | 683556 | ₹30.0 L+₹1.2 L (4.13%) | L4 | Rejected-AOC Rejected |
| 5 | L5₹30.3 L+₹1.6 L (5.41%)Rejected-AOC 22 1685 ST JACOB CHURCH LANE PAMBAIMOOLA EDACOCHIN ERNAKULAM KERALA 682010 | ERNAKULAM | ERNAKULAM | KERALA | 682010 | ₹30.3 L+₹1.6 L (5.41%) | L5 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | WELTRONENGINEERINGSERVICES L9 | ZOOM ENTERPRISES L5 | Kuriako Mathai and company L4 | M/S AARJAY ASSOCIATES L2 | Super Constructions L7 | AVM CONSTRUCTION L6 | ELAN ENGINEERS L8 | Bell Builders L3 | M/s S & S Enterprises/ Suresh Shivasankarapillai L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of Brick work or stone/boulder masonry, laid built in cement mortor complete all as specified and directed | 3 | Cum | 1,325 ₹3,975 | 1,400 ₹4,200 | 1,350 ₹4,050 | 1,250 ₹3,750 Lowest | 1,400 ₹4,200 | 1,550 ₹4,650 | 1,605 ₹4,815 | 1,500 ₹4,500 | 1,250 ₹3,750 Lowest |
| 2.00 | M&L Pre-cast cementconcrete block masonry with solid blocks, exc. 10cm in width and setting in mortar,complete Type C 1 1:3:6 set in CM 1:6 complete all as spd and directed by Engineer in Charge | 10 | Cum | 9,500 ₹95,000 | 12,000 ₹1,20,000 | 9,000 ₹90,000 Lowest | 10,000 ₹1,00,000 | 9,500 ₹95,000 | 9,300 ₹93,000 | 9,105 ₹91,050 | 9,500 ₹95,000 | 9,680 ₹96,800 |
| 3.00 | Taking down cement plaster on brick or stone wall etc including raking out joints, hacking for keys, scrubbing down with water etc.complete all as specified and directed | 360 | Sqm | 110 ₹39,600 | 120 ₹43,200 | 90 ₹32,400 Lowest | 95 ₹34,200 | 100 ₹36,000 | 110 ₹39,600 | 95 ₹34,200 | 90 ₹32,400 Lowest | 90 ₹32,400 Lowest |
| 4.00 | M&L Rendering 15mm thick on fair faces of brick work in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed | 280 | Sqm | 330 ₹92,400 | 340 ₹95,200 | 350 ₹98,000 | 310 ₹86,800 Lowest | 310 ₹86,800 Lowest | 350 ₹98,000 | 395 ₹1,10,600 | 350 ₹98,000 | 315 ₹88,200 |
| 5.00 | M&L Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces incl finished even and smooth without using extra cement complete all as specified and directed | 130 | Sqm | 350 ₹45,500 | 360 ₹46,800 | 350 ₹45,500 | 330 ₹42,900 Lowest | 330 ₹42,900 Lowest | 350 ₹45,500 | 345 ₹44,850 | 375 ₹48,750 | 345 ₹44,850 |
| 6.00 | M/L for Preperation of new plastered surfaces of wall and apply of two coats of oil bound distemper over a coat of primer complete all as specified and directed | 280 | Sqm | 130 ₹36,400 | 120 ₹33,600 | 125 ₹35,000 | 120 ₹33,600 | 110 ₹30,800 | 100 ₹28,000 | 85 ₹23,800 Lowest | 100 ₹28,000 | 125 ₹35,000 |
| 7.00 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. | 130 | Sqm | 130 ₹16,900 | 150 ₹19,500 | 175 ₹22,750 | 150 ₹19,500 | 140 ₹18,200 | 150 ₹19,500 | 125 ₹16,250 Lowest | 140 ₹18,200 | 150 ₹19,500 |
| 8.00 | M/L for Complete removal of existing treatment and preparation of old surfaces of wall and applying two coat of oil bound distemper over a coat of primer complete all as specified and directed | 40 | Sqm | 125 ₹5,000 Lowest | 150 ₹6,000 | 150 ₹6,000 | 140 ₹5,600 | 165 ₹6,600 | 160 ₹6,400 | 185 ₹7,400 | 160 ₹6,400 | 145 ₹5,800 |
| 9.00 | M/L for Complete removal of existing treatment and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. | 30 | Sqm | 165 ₹4,950 Lowest | 180 ₹5,400 | 175 ₹5,250 | 175 ₹5,250 | 190 ₹5,700 | 250 ₹7,500 | 205 ₹6,150 | 180 ₹5,400 | 170 ₹5,100 |
| 10.00 | Excavation in trenches in soft/loose soil not exc 1.5 m wide and not exceeding 1.5 mtr in depth for foundation etc shaft, cesspits, manholes etc not exc. 10 sqm on plan and getting out complete all as specified & directed. | 12.5 | Cum | 345 ₹4,312.5 Lowest | 390 ₹4,875 | 400 ₹5,000 | 360 ₹4,500 | 420 ₹5,250 | 350 ₹4,375 | 375 ₹4,687.5 | 350 ₹4,375 | 365 ₹4,562.5 |
Tender Value
₹28.8 L
EMD Value
₹57,600
Closing Date
23 Jul 2025, 6:00 pmClosed
Shri RK Singh IDSE CWE(NW) Kochi
CWE(NW) Kochi
ADDITION ALTERATION AND SPECIAL REPAIR TO BUILDING NO. P-33 AT AYUDH VIHAR RESIDENTIAL AREA OF NAD ALWAYE
2025_MES_718188_1
CWE(NW)KOCHI/81563
Open Tender
Civil Works
Item Rate
180 days
Kochi
As per NIT
7 documents required · 7 mandatory
₹500
GE(NS) Kochi
₹57,600
Yes
20 Sept 2025
2 Jul 2025
25 Jul 2025
2 Jul 2025
23 Jul 2025
16 Jul 2025
Amount
Demolition of Brick work or stone/boulder masonry, laid built in cement mortor complete all as specified and directed
M&L Pre-cast cementconcrete block masonry with solid blocks, exc. 10cm in width and setting in mortar,complete Type C 1 1:3:6 set in CM 1:6 complete all as spd and directed by Engineer in Charge
Taking down cement plaster on brick or stone wall etc including raking out joints, hacking for keys, scrubbing down with water etc.complete all as specified and directed
M&L Rendering 15mm thick on fair faces of brick work in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed
M&L Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces incl finished even and smooth without using extra cement complete all as specified and directed
M/L for Preperation of new plastered surfaces of wall and apply of two coats of oil bound distemper over a coat of primer complete all as specified and directed
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
M/L for Complete removal of existing treatment and preparation of old surfaces of wall and applying two coat of oil bound distemper over a coat of primer complete all as specified and directed
M/L for Complete removal of existing treatment and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
Excavation in trenches in soft/loose soil not exc 1.5 m wide and not exceeding 1.5 mtr in depth for foundation etc shaft, cesspits, manholes etc not exc. 10 sqm on plan and getting out complete all as specified & directed.
Returning, filling in, trenches the soil in layers not excceding 25 cm thick, watering and well ramming complete all as specified and directed.
Removal of surplus soil to a distance exc 250 mtr but not excceding 500 mtr away & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L Cement concrete type D2 1:4:8 ( 40mm graded stone aggregate) as in foundations, filling and mass-concrete complete all as specified.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed
S&F pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof overing/cladding to all, fixed with self tapping screws all as specified .
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Dismantling timber scantling 40 sq.cm and over in section in any position complete all as specified.
Dismantling of existing timber framed work in fillets , rails, posts, rafters, purlins etc under 4 sq cm in section complete all as specified.
M&L Roof tiles, Mangalore pattern, interlocking at side joints, laid dry complete all as specified and directed
M&L ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in lime mortar 1:3 or cement mortar 1:6 complete all as specified and as directed by Engg In Charge.
S&F steel work in tubular trusses, I section,angle, as purlins,rafter etc including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979Grade St-240 for square or rectangular tube complete all as specified
Preparation of new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed
S & F Anodised aluminium snap grid frame work for false ceiling with size of grid 605x605mm all as specified
S&F 12 mm thick Gypsum board in ceiling fixed with screw as per manufacturers instructions complete all as specified and directed by Engr-in-Charge.
Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) not exc. 1.50 sqm each and removing from store complete all as specified.
Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) exc. 1.50 sqm but n.exc 4 sqm each and removing from store complete all as specified.
M&L solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube, suppling & fixing in opening as per specification & drawing
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F Anodised aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
M&L Anodised aluminium powder coated door shutters aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing handle 2 nos in each door hinges anodised aluminium snap beading screw etc complete all as specified.
M/L aluminium powder coated window and ventilator shutters, fixed type/ side hung type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, Powder coated aluminium snap beading, screws etc. complete all as specified
S&F sheet glass ordinery quality frosted on one side, 4mm thick and glazing with oil putty/wooden beads in squars n exc 0.5 sqm each pane.
S & F in aluminium extruted body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as spd and as directed by Enginee in Charge
M&L Dismantling floor, hearth or wall tiling including cement mortor bedding complete all as specified and directed
M&L 25mm thick cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in floor finished even and fair complete all as specified and directed
S&F Vitrified ceramic tiles light shade 10mm thick (square/rectangular) area of each tile exc 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or bedding layers in CM 1:6. complete all as specified and directed.
All as per item No.37 but skirting over 10 mm thick CM 1:3 plater complete all as specified and directed
M&L for Joint free Non skid Ceramic coloured tiles 7-8 mm thick (square/ rectagular) polished,area of each tiles exc 0.11sqm but not exceeding 0.18 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding in CM 1:6 complete all as specified and as directed cement to match complete all as specifed and as directed
M/L for Glazed ceramic coloured tiles in vertical surface 350x250x7mm/ 450x350x7mm thick over 10mm thick screed bed in CM 1:4, set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed
M&L 20mm thick Granite(of any type) machine cut, in cooking platform incl bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing types over 20mm cement screed 1:4 and jointed with grey cement slurry mixed with pigment to match the shed of the slab including rubbing and polishing complete all as specificed and directed.
Rounding to edges of stone slab one edge cooking platform and other simlar work complete all as specificed and directed.
M&L for re-inforced cement concrete 1:2:4 Type B0 using 12.5 mm graded stone aggregate as in fins, facias, parapets , slab etc.complete all as specified and directed
M&L formwork to sides and soffits of floor or roof beams, beam haunchings,girders, bressummers,lintels, cantilevers, shelves including supports,overhangs,etc. also splays between floors and beams, etc.
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
S & F in repair vitreous china, wash down water closet (EWC) with seat cover coloured, closed pattern with flat bottom and cover with mild steel (CP) or aluminium hinging device fixed with necessary bolts complete all as specified.
S & F Wash basins (size 580x450mm), Vitreous China (flat back or angle back type) in repair, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe
S & F in repairs, 10 ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed
S&F Chromium plated fancy type bib tap 15mm complete all as specified and directed
S & F Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and directed.
S & F PVC connection 15mm with PTMT nuts of length 450mm long complete all as specified and directed.
S & F in repairs chromium plated fancy type pillar cock 15mm dia complete all as specified and directed
S&F in repairs fancy type 15mm dia CP angle Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed
M & L for cutting holes in brick work for concealed water tubing and making good to facing where required and pointing to cement mortor 1:3, cutting not exc 10 cm girth complete all as specified and directed.
Taking down GI tubing 15mm complete all as specified and directed.
Taking down GI tubing 20mm complete all as specified and directed.
Supplying and laying of CPVC pipes 20mm outer diameter, SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified.
Supplying and laying of CPVC pipes 25mm outer diameter, SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified.
S & F grating doom 100mm dia of PTMT complete all as specified and directed.
S & F 32mm dia waste fittings, brass,chromium plated for glazedware sinks, basins, etc.with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed in wash basin complete all as specified and directed.
S&F waste pipe for wash basin of size 32mm dia complete all as specified and directed
S & F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S & F brass chromium plated tubular towel rail 20mm dia D type 60 cm long between flanges complete all as specified and directed.
Demolition of cement concrete in ground floors and paving n.exc 15 cm thickness below or above ground level complete allas specified.
M&L for 100mm thick PCC 1:3:6 Type C2 40mm graged aggregate as in sub base floor complete all as specified.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment incl 15mm thick screed bed 1:6 complete all as specified.
M&L for Cement concrete tiles 30cm x 30cm x 20mm thick, machine pressed over 20mm thick screed bed in CM 1:6 and set jointed and pointed with grey cement with pigment in neat cement slurry in floors, and cut and polished complete all as specified and directed.
M&L Providing, cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in hunching, coping , benching etc complete all as specified as directed.
M&L for 50mm thick PCC 1:3:6 Type C1 20mm graged aggregate as in plinth protection finished even and smooth using extra cement complete all as specified.
Dismantling and cleaning of old APP roof treated surface any description complete all as specified and directed.
M&L for PCC screed to slope including providing batching mixing transporting and laying controlled screed concrete of M20 grade of average 75mm thickness with a minimum thickness of 50mm at drain points and slope of 1:150 or required as per the site condition at all levels by admixing necessary admixtures CONPLAST WL or equivalent @150ml per bag or cement and mixing graded fibrillated 100% virgin poly propylene fibres in concrete at the rate of 0.9Kg/cum as per manufactures specification.
M&L Rendering 10mm thick in CM 1:3 on roof surfaces incl finished even and smooth without using extra cement with WPC complete all as specified and directed Note : WPC will measured and paid seperately.
Supply only liquid water proofing compound complete all as specified and directed.
Material and Labour preparation of roof surface by throughly wire brused ,washed ,dried up,cleaned of all the forein matters and dust ,and applying bitumenous primer @250gms/sqm ,and then laying 4mm thick APP modified bituminous membrane with non woven polyster matt as reinforced weighting not less than 4.00kg per sqm ,laid on primed surface with torch application method by providing overlap minimum 100mm longitudnal and 150mm on transerve direction .All angles and similar projections should be sealed well with extra care to ensure full bondage,all joints and changes in direction should be curved with cement mortar 1:3 mixed with SBR Latex @ 200ml /bag of cement.
S&F in repair 1.25mm thick Steel rolling shutters, with out ball bearing, as specified including top cover, an?choring rod, hasp and staple and one shop coat of primer; erected in position as indi?cated, complete: push pull or manual type complete all as specified as directed.
S&F in repair Safety leaver locks mild steel with 4 levers for rolling shutters complete all as specified as directed.
S&F in repair Ball bearing for rolling shutters complete all as specified as directed.
Taking down existing steel rolling shutters from brackets with all connected fittings such as shaft,helical spring ,bearing,bottom plate,top cover etc and removing from site complete all as specified as directed.
Taking down existing steel rolling shutters from brackets with all connected fittings such as shaft,helical spring ,bearing,bottom plate,top cover,anchoring rod,haps and staple etc checking for thear function , replacing any worn out and unserviceable parts as required greasing ,welding,reparing,servicing for smooth functioning of shutter and connected items and refixing to their orisinal position complete all as directed.(Replacement of items will be measured seperately)
S&F Bottom plate with 2.5mm thickness and with widtg suitable for fixing of existing shutter including connected items for fixing complete all as specified as directed.
S&F steel top cover of thickness not less than 0.9mm and with widtg suitable for fixing to existing rolling shutter and to cover up the top portion completely including end plate and all connetted items ig requires for fixing complete all as specified.
S&F Steel lath for rolling shutters not less than 1.25mm thick and with strip width suitable for fixing to existing rolling shutters including connected items for fixing complete all as specified.
S&F helical spring for counter balancing rolling shutters made from high tension steel spring, 7mm thick and 45cm long complete all as specified.
M&L for preparation of old painted surfaces exc 10cm width or girth and applying one coat of synthetic enamel paint on steel/iron surfaces all as specified
S&F PVC (SWR) pipes single socketed in any length 75mm bore with rubber ring joints fixed to walls complete all as specified.
S&F PVC (SWR) bends any radius mm bore complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed
Supplying and laying of CPVC pipes SDR 13.5 & Plain CPVC SDR 11 fittings in trenches complete all as specified for 25 mm outer dia bore.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified for 20 mm outer dia bore complete all as specified and directed.
S&F, 500 litres capacity Rotational moulded polyethylene water storage tanks (ISI marked) (Cylindrica; vertica; with closed top) hoisted & fixed in position complete all as specified and as directed.
Supply and fix, Ball brass valves,high pressure 25mm with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed
M&L for PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) Cement concrete in foundations, filling and mass concrete.(Foundation to water tank) complete all as specified and directed
Supply and fixing , CPVC Ball Valve outer diameter 25 mm screwed both ends or flanged complete all as specified and directed
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above SSRs should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed
M& L for Point wiring using approved colour coding as per IS(Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross sectional area, copper conductor unsheathed FRLSH cable 1100 Volts grade including PVC Open conduit and connected accessories ISI marked with concealed sunken boxes with modular cover plate, PVC boxes, modular outer cover etc of suitable moudules, including 1.5 sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLSH cable single core multistranded cable as earth continuity wire for one light controlled by one switch complete all as specified and as directed by Engr-in-charge.
All as per item No 97 but One ceiling fan point controlled by one switch complete all as specified and directed
All as per item No 97 but One exhaust fan point controlled by one switch complete all as specified and directed
All as per item No 97 but One 3 pin socket outlet 5 amps on the independent board complete all as specified and directed
All as per item No 97 but with cable 4 sqmm for One 3/5 pin socket outlet 15 amps on the independent board complete all as specified and directed
Supply and Fix in repairs Modular Switch 1 way, 6 Amps, 1 module complete all as specified and directed.
Supply and Fix in repairs Modular Socket, 6 A- 2/3 pin combined 2 module complete all as specified and directed.
Supply and Fix in repairs Modular Socket, 6/16 A- 2/3 pin combined 2 module complete all as specified and directed.
Supply and Fix in repairs Modular Switch 1 way, 16 Amps, 1 module complete all as specified and directed.
Supply and Fix in repairs Modular fan step regulator 120w, 2 module complete all as specified and directed.
S&F Ceiling rose in repairs , 3 phase/PVC/polycarbonate, isolated body, 65 x 50mm, 3 terminals complete all as specified and directed
Supply and fix LED tube light fitting of 20 watt, Extruded aluminium housing enhances safety, high quality PC Diffuser, easy to install Efficacy 110/125 lumen/watt complete all as specified and directed.
S&F in repairs, SPN, 16 way MCB distribution board, with 200 Amps rated bus bar, double door flush type, with IP-54 protection, isolated neutral bars, door earthing, suitable for SPN/DP MCB/RCBO as incomer and SP MCB as outgoing complete with all accessories all as specified and directed by Engineer-in Charge.
Supply and fixing, in repairs, SPN-63 Amps rating 240V, 10KA 'B' curveminiature circuit breaker (MCB) and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing, in repairs, SPN-32 Amps rating 240V, 10KA 'B' curveminiature circuit breaker (MCB) and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing in repairs 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
Material and Labour for 50 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc including clamps, nut, bolt and washers etc after taking out unserviceable pipe complete all as specified and directed.
Taking down fan, ceiling cable end,dismantling blades and removing fan and blades to store complete all as specified and directed.
M & L for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed.
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFMwith service value 6.00 BEE. Five starrated with brushless direct current motor (BLDC) complete all as specified and directed.
S & F exhaust fan, steel body AC single phase 230V of size 300mm sweep with blade and frame and louvers complete all as specified and directed.
M & L in repairs for Earthing complete with GI Steel earth plate electrode 600 × 600 × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) earth plate paced on all side with charcoal mixed with salt to a thickness of 150mm in layers,with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth wire of size 4 mm, dia by means of bolts, nuts, check soldered and revetted to earth plate. Earth wire will be protected by using 15mm dia bore GI pipe light grade. The earthing includes PCC Pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 mtrs etc complete all as shown in electrical plate No. 3 of SSR Part-I 2009,connected to earthing test point all as specified or indicated including testing on completion
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and directed.
M/S AARJAY ASSOCIATES (BID ID -3368312)
Bell Builders (BID ID -3367889)
Kuriako Mathai and company (BID ID -3367936)
ZOOM ENTERPRISES (BID ID -3367823)
AVM CONSTRUCTION (BID ID -3368214)
Super Constructions (BID ID -3368599)
ELAN ENGINEERS (BID ID -3367464)
WELTRONENGINEERINGSERVICES (BID ID -3367411)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .