Design, Supply, Erection, Testing, Commissioning & Modification of 25 KV AC OHE of Multitracking between Chhayapuri - Bajwa section on Vadodara Division of Western Railway.
TR-C-10-2025-26-T-RI~WR
TR-C-10-2025-26-T-RI
Open
Works - General
6 Months
Vadodara, Gujarat
₹0
₹3.5 L
6 Mar 2026
11 Feb 2026
20 Feb 2026
excavation and supply of all materials viz., sand, cement, and ballast etc.) S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Schedule () B-Steel items 23616123.00 Please see Item Breakup for details. 13476000.00 AT Par 13476000.00
and Bridge mast, AT masts, Feeder mast etc. Please see Item Breakup for details. 1694130.00 AT Par 1694130.00
portals etc. (SPS) Please see Item Breakup for details. 4914180.00 AT Par 4914180.00
and inside the tunnel. Please see Item Breakup for details. 54845.00 AT Par 54845.00 4 Description:- Supply of pull-off arrangement for OHE. Please see Item Breakup for details. 220300.00 AT Par 220300.00 5 Description:- Supply of guy rod assembly Please see Item Breakup for details. 1019358.00 AT Par 1019358.00
counter weight assembly and SS wire rope for conventional OHE as per RDSO Spec. TI/SPC/OHE/ATD/0060(Rev. 2) or latest for conventional OHE. Please see Item Breakup for details. 1096000.00 AT Par 1096000.00 7 Description:- Supply of all types of GI bonds (40 X 6 mm) DYCEE-C-BRC-ELEC/WESTERN RLY Please see Item Breakup for details. 51900.00 AT Par 51900.00 8 Description:- Supply of Earth electrode Please see Item Breakup for details. 9750.00 AT Par 9750.00 9 Description:- Supply of GI flat for earth (50 X 6 mm) Please see Item Breakup for details. 263580.00 AT Par 263580.00 10 Description:- Supply of Antibird disc on insulator end fitting Please see Item Breakup for details. 652080.00 AT Par 652080.00 11 Description:- Supply of Anti Monkey Climbing device (AMCD) as monkey scare for mast Please see Item Breakup for details. 145200.00 AT Par 145200.00 12 Description:- Supply of Anti Monkey Climbing device as monkey scare for Portal Please see Item Breakup for details. 18800.00 AT Par 18800.00
type-III, UV stabilized s per IS 16008(Part-2)-2016/PVC Virgin HDPE Net Preferably in black colour. S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Schedule () C-Switch Gear, Insulators & other Elec. Items 2107380.00 Please see Item Breakup for details. 273226.00 AT Par 273226.00 1 Description:- Supply of 25 KV double pole, 3150A isolator with interlocking mechanism. Please see Item Breakup for details. 410220.00 AT Par 410220.00 2 Description:- Supply of 25KV single pole, 1600A isolator without earth contact assembly. Please see Item Breakup for details. 292700.00 AT Par 292700.00
insulator) of overhead equipment. Please see Item Breakup for details. 83508.00 AT Par 83508.00 4 Description:- Supply of materials for termination of single conductor with 9 t cut-in insulator Please see Item Breakup for details. 314352.00 AT Par 314352.00 5 Description:- Supply of section insulator assembly including core and cut-in insulator. Please see Item Breakup for details. 171020.00 AT Par 171020.00 6 Description:- Supply of 25KV solid core cut-in insulator Please see Item Breakup for details. 271170.00 AT Par 271170.00 7 Description:- Supply of 25KV solid core suspension insulator. Please see Item Breakup for details. 170700.00 AT Par 170700.00 8 Description:- Supply of 25KV post insulator Please see Item Breakup for details. 32538.00 AT Par 32538.00
supply. Please see Item Breakup for details. 87946.00 AT Par 87946.00
& Anti climbing device. S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Schedule () D-Copper items and PVC cables 1762715.00 Please see Item Breakup for details. 1589295.00 AT Par 1589295.00
supply of number plates & various types of caution & other boards including shock treatment chart etc. Please see Item Breakup for details. 9320.00 AT Par 9320.00 2 Description:- Supply of Catenary wire splice Over & above as required for item D1 Please see Item Breakup for details. 23940.00 AT Par 23940.00 3 Description:- Supply of Contact wire splice over & above as required for item D1 Please see Item Breakup for details. 13340.00 AT Par 13340.00 4 Description:- Supply of copper strip for earthing (25mm x 3mm) Please see Item Breakup for details. 71880.00 AT Par 71880.00 5 Description:- Supply of 18mm solid copper busbar. Please see Item Breakup for details. 54940.00 AT Par 54940.00
DYCEE-C-BRC-ELEC/WESTERN RLY S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Schedule () E-Erection 4474873.00 Please see Item Breakup for details. 127464.00 AT Par 127464.00
As erected LOP,SED,TWR with appendix etc. Please see Item Breakup for details. 843480.00 AT Par 843480.00
transformer masts, TTC and portals Please see Item Breakup for details. 103620.00 AT Par 103620.00 3 Description:- Erection of fabricated and galvanized steel works other than traction mast (SPS) Please see Item Breakup for details. 387320.00 AT Par 387320.00
and inside the tunnel Please see Item Breakup for details. 6405.00 AT Par 6405.00 5 Description:- Erection of pull-off arrangement for OHE Please see Item Breakup for details. 38575.00 AT Par 38575.00 6 Description:- Erection of guy rod assembly Please see Item Breakup for details. 113040.00 AT Par 113040.00
including counter weight assembly and SS wire rope for conventional OHE as per RDSO Spec. TI/SPC/OHE/ATD/0060(Rev. 2) or latest for conventional OHE. Please see Item Breakup for details. 276000.00 AT Par 276000.00 8 Description:- Erection of all types of GI bonds Please see Item Breakup for details. 18804.00 AT Par 18804.00 9 Description:- Erection of Earth electrode Please see Item Breakup for details. 3300.00 AT Par 3300.00 10 Description:- Erection of GI flat for earth (50mmx6mm) laid in ground/exposed Please see Item Breakup for details. 19020.00 AT Par 19020.00 11 Description:- Erection of 25 KV double pole isolator with interlocking mechanism Please see Item Breakup for details. 23660.00 AT Par 23660.00 12 Description:- Erection of 25KV single pole isolator without earth contact assembly Please see Item Breakup for details. 37150.00 AT Par 37150.00
cut-in insulator) of overhead equipment. Please see Item Breakup for details. 40250.00 AT Par 40250.00 14 Description:- Erection of anti-creep with 9T insulator over & above as incl. in E21 Please see Item Breakup for details. 36960.00 AT Par 36960.00 15 Description:- Erection of section insulator assembly including core and cut-in insulator Please see Item Breakup for details. 18820.00 AT Par 18820.00 16 Description:- Erection 25KV solid core cut-in insulator Please see Item Breakup for details. 33030.00 AT Par 33030.00 17 Description:- Erection of 25KV solid core suspension insulator Please see Item Breakup for details. 17580.00 AT Par 17580.00 18 Description:- Erection of 25KV Post/Support insulator Please see Item Breakup for details. 3220.00 AT Par 3220.00
supply Please see Item Breakup for details. 6408.00 AT Par 6408.00
assembly, LV box & anti climbing device Please see Item Breakup for details. 332025.00 AT Par 332025.00
wires, fixing of number plates & various type of boards Please see Item Breakup for details. 75000.00 AT Par 75000.00
cable from AT to DB DYCEE-C-BRC-ELEC/WESTERN RLY Please see Item Breakup for details. 480.00 AT Par 480.00 23 Description:- Erection of copper strip for earthing. (25 x 3mm) Please see Item Breakup for details. 5580.00 AT Par 5580.00 24 Description:- Erection of 18mm solid copper busbar. Please see Item Breakup for details. 820.00 AT Par 820.00 25 Description:- Erection of 18mm solid copper busbar terminal Please see Item Breakup for details. 6800.00 AT Par 6800.00 26 Description:- Erection of 150 sqmm copper feeder wire. Please see Item Breakup for details. 197360.00 AT Par 197360.00 27 Description:- Transfer of OHE from one support to another and adjustment of droppers Please see Item Breakup for details. 76388.00 AT Par 76388.00
catenary wire etc. Please see Item Breakup for details. 4259.00 AT Par 4259.00 29 Description:- Dismantling & removal of Auxiliary transformer with DO fuse Please see Item Breakup for details. 10674.00 AT Par 10674.00 30 Description:- Dismantling & removal of Isolator complete Please see Item Breakup for details. 143720.00 AT Par 143720.00 31 Description:- Dismantling & removal of Mast, portal, TTC & other small part steel Please see Item Breakup for details. 137450.00 AT Par 137450.00 32 Description:- Breaking of concrete foundation of Masts, portals & TTC Please see Item Breakup for details. 15876.00 AT Par 15876.00 33 Description:- Dismantling & removal of Guy rod assembly Please see Item Breakup for details. 34000.00 AT Par 34000.00 34 Description:- Dismantling of feeder wire Please see Item Breakup for details. 42072.00 AT Par 42072.00 35 Description:- Providing (Supply & erection) of Sectioning diagram board at stations Please see Item Breakup for details. 31000.00 AT Par 31000.00 36 Description:- Digging of Cable trench 450mm wide and 1200mm depth Please see Item Breakup for details. 52000.00 AT Par 52000.00 37 Description:- Supply and laying of bricks and sand in cable trench for protection of cable. Please see Item Breakup for details. 10020.00 AT Par 10020.00 38 Description:- Tree Trimming / cutting Please see Item Breakup for details. 79410.00 AT Par 79410.00
various size upto 450 mm dia. Please see Item Breakup for details. 51980.00 AT Par 51980.00 40 Description:- Erection of Antibird disc Please see Item Breakup for details. 69720.00 AT Par 69720.00 41 Description:- Erection of Anti Monkey Climbing device as monkey scare for mast Please see Item Breakup for details. 11620.00 AT Par 11620.00 42 Description:- Erection of Anti Monkey Climbing device as monkey scare for Portal Please see Item Breakup for details. 7400.00 AT Par 7400.00
type-III, UV stabilized as per IS 16008 (Part-2) -2016/PVC Virgin HDPE Net Preferably in black colour. Please see Item Breakup for details. 43200.00 AT Par 43200.00
Please see Item Breakup for details. 47350.00 AT Par 47350.00
mounting arrangement for different type of mast and portal for existing line. Please see Item Breakup for details. 193040.00 AT Par 193040.00
OHE. Please see Item Breakup for details. 120505.00 AT Par 120505.00 47 Description:- Supply & Erection of a 160sqmm Copper Jumper on existing OHE Please see Item Breakup for details. 108500.00 AT Par 108500.00 48 DYCEE-C-BRC-ELEC/WESTERN RLY 48 Description:- Provision of False Catenary Under FOB for Existing OHE Please see Item Breakup for details. 41172.00 AT Par 41172.00 49 Description:- Splicing & extension on existing OHE (where require) Please see Item Breakup for details. 35256.00 AT Par 35256.00 50 Description:- Dismantling of section insulator other than Schedule item No. E28. Please see Item Breakup for details. 8760.00 AT Par 8760.00 51 Description:- Dismantling of Existing Anti creep other than Schedule item No. E28. Please see Item Breakup for details. 27095.00 AT Par 27095.00 52 Description:- Dismantling of Regulating Equipment other than Schedule item No. E28. Please see Item Breakup for details. 5755.00 AT Par 5755.00 53 Description:- Dismantling of Termination other than Schedule item No. E28. Please see Item Breakup for details. 104000.00 AT Par 104000.00
Transportation of Released material from work site to Railway depot. Please see Item Breakup for details. 190480.00 AT Par 190480.00
Traffic block is subject to have extra rate.
The price shall include all works mentioned in cum all classes of soil, concrete or, masonry/drains/walls and rock. The price shall also include the cost of digging, cement concrete & soil refilling. The price shall be same for any shape and size of concrete blocks for foundation, in calculating the individual volume of concrete, fraction of a cubic meter beyond the third decimal shall be rounded off to the next nearest third decimal. The price shall apply for concreting of all foundations for masts, gantries, portals, anchor blocks for guy rods and fencing uprights. For purposes of computation of volume of concrete, the volume of steel work embedded in the foundation block and muff shall be ignored. Cost of all concrete will be paid for only under item No.1 and the prices of other item shall not include. For purposes of compilation of volume of concrete, the volume of concrete shall include the volume of sand and bitumen in sand core foundation. For purposes of compilation of volume of concrete, the volume of each muff for all masts shall be taken as 0.02 cum., except for masts with balance weights and for column of portal, each head span masts, 2 or 3 track cantilever masts and special fabricated masts for which the volume of muff shall be taken as 0.08 cum. irrespective of the size and shape of muff on a flat basis. Mixture for casting of foundation shall be 1:3:6 and mixture for grouting shall be 1:2:4. Curing of foundation shall be done by contractor for 28 days. No scroll will be supplied by Railway; contractor will use his scroll. Necessary details like, type, implantation, chainage shall be supplied by Railway. Contractor has to prepare standard cube of size 150x150x150mm for every 25 cum of foundation cast & is to be tested in the Govt. approved laboratory as per IS- 516/1959(or Latest) to obtain the result as per DYCEE-C-BRC-ELEC/WESTERN RLY 516/1959(or Latest) to obtain the result as per IS 456/1978. Cement used shall OPC cement grade 53 only to confirm latest IS of OPC cement grade 53. The price also cover cost for smooth plasters on exposed foundation and muff. Note: for Schedule "A" 1.The prices under item shall be same for any shape of size of Concrete blocks, cable trenches & brick wall. In calculating the individual volume of concrete and brick wall fraction of a cubic meter beyond the third decimal shall be rounded off to the nearest third decimal. 2.The prices under Item shall apply for concreting at all pedestals plinths and foundations for gantries/portals and supporting steel work and cable trenches. 3.For purpose of computation of volume of concrete and brick wall under Item, the volume of steel work embedded in the foundation block or muff shall be ignored. 4.The volume of each muff will be included in the volume of concrete for the respective foundation for purpose of computation of volume of concrete. 5.The prices shall include cost of embodiment of drain pipes, conduits for cable or earthing flats where necessary. 6.In respect of concrete for cable trenches the price shall not include the cost of cable supports and trays, which shall be supplied and erected by the contractor and shall be paid for under item. 7.Dowel bars in special foundations and nominal reinforcement in block cotton soil foundation will be necessary such nominally reinforced foundations in black cotton soil will be payable under item. The steel for nominal reinforcement and dowel bars will be supplied by the contractor and the concrete mixture in such a case shall be as for normal foundation 1:3:6. Total 7331590.00 Schedule Schedule B-Steel items Supply of rolled or fabricated and galvanized traction mast, TTC, Portal with boom and Bridge mast, Item- 1 AT masts, Feeder mast etc. S No. Item Description of Item Unit Qty Rate Amount No DYCEE-C-BRC-ELEC/WESTERN RLY
Supply of traction main masts of OHE MT comprising rolled, broad flanged beams, fabricated K- series, B series, portal upright, boom pieces & associated fittings, D.A., extension chairs and AT Masts, feeder mast, bridge mast etc. 1.The price shall cover cost of fabrication, galvanization, and supply of individual tractions masts & Bridge mast. 2.Galvanization shall be as per Railway Specification No. ETI/OHE/13(4/84) with C.S. No. 4 (05/2018) or latest with galvanization thickness of 1000 gram per sq. meter. 3.In case, required size of channels are not available as per approved drawing, higher size of channels can be used with approval of Dy. Chief Electrical Engineer (construction) and payment as per actual black weight will be paid. 4.The price shall also include the straightening of masts/portal uprights etc bent during transit and cutting of masts/portal uprights to suit the site condition. 5.For standard fabrication of steel work or structures for which RDSO/CORE approved drawing are available, the black steel weight of steel work as specified in RDSO/CORE drawing, shall be considered for payment. 6.However in case the unit sectional weight of any member indicated in RDSO's drawing is not in conformity with the unit sectional weight as per the latest IS specification the weight of the fabricated steel work shall be calculated on the basis of latest IS specification and the same will be considered for payment for the nonstandard fabricated steel work, the calculated weight to be considered for payment under this item shall be included in the relevant drawing based on latest IS sectional weight at the time of submitting the designs for approval of the purchaser. 7.There will be no addition for increased weight due to galvanizing or painting or reduction for holes or screw cut. 8.Galvanization damaged during transportation/ carting will be touch up with cold ZINC paints by tenderer. 9.Crane will be arranged by railway for Portal boom erection only on demand by contractor. 10.Materials will be supplied at site of work. 11.Payable unit weights for standard mast. 12. Sr. No.Type of mastBlack Weight (Kg) as per drawingSr. No.Type of mastBlack Weight (Kg) as per drawing 16"x6"x25.15 BFB352.4513NB- 4210.20 28"x6"x35 RSJ494.0014NB-5252.36 3B-150369.6915NB-6301.95 4B- 175422.8916RU627.48 5B-200474.1917RE- 1634.33 6B-250695.2718RE-2660.56 9NU365.2619RB-1432.58 8NE1183.8820RB- 2507.71 9NE2199.1821RB-3586.49 Sr. No.Type of mastBlack Weight (Kg) as per drawingSr. No.Type of mastBlack Weight (Kg) as per drawing 10NB168.8322RB-4665.26 11NB2110.9923RB-5717.88 12NB-3160.58 Total 13476000.00 Item- 2 Supply of fabricated and galvanized steel works other than traction mast, TTC, portals etc. (SPS) S No. Item Description of Item Unit Qty Rate Amount No DYCEE-C-BRC-ELEC/WESTERN RLY
The price shall cover cost for supply of SPS for MT different type of masts, portals, DA, isolator, boom. Payment of SPS will be made as per black steel weight of material as per RDSO/CORE latest approved drawings and supplier. 1.The price shall cover cost of fabrication, galvanization, supply setting before grouting of individual tractions masts. 2.Galvanization shall be as per Railway Specification No. No. ETI/OHE/13(4/84) with C.S. No. 4 (05/2018) or latest with galvanization thickness of 1000 gram per sq. meter. 3.In case, required size of channels are not available as per approved drawing, higher size of channels can be used with approval of Dy. Chief Electrical Engineer (construction) and payment as per actual black weight will be paid. 4.The price shall also include the straightening of masts/portal uprights etc bent during transit and cutting of masts/portal uprights to suit the site condition. 5.For standard fabrication of steel work or structures for which RDSO/CORE approved drawing are available, the black steel weight of steel work as specified in RDSO/CORE drawing, shall be considered for payment. 6.However in case the unit sectional weight of any member indicated in RDSO's drawing is not in conformity with the unit sectional weight as per the latest IS specification the weight of the fabricated steel work shall be calculated on the basis of latest IS specification and the same will be considered for payment for the nonstandard fabricated steel work, the calculated weight to be considered for payment under this item shall be included in the relevant drawing based on latest IS sectional weight at the time of submitting the designs for approval of the purchaser. 7.There will be no addition for increased weight due to galvanizing or painting or reduction for holes or screw cut. 8.Galvanization damaged during transportation/ carting will be touch up with cold ZINC paints by tenderer. 9.Materials will be supplied at site of work. Total 1694130.00 Supply of single cantilever assembly complete with insulator for conventional OHE and inside the Item- 3 tunnel. S No. Item Description of Item Unit Qty Rate Amount No DYCEE-C-BRC-ELEC/WESTERN RLY
1.The price shall cover on a flat rate basis for Each supply of bracket assembly with all required component on a traction mast or Support on drop arm and shall include those on high/low level platform in the vicinity of turnouts over bridges or overlaps and at all locations with reduced encumbrance/ terminating wires as per latest RDSO drawing. 2.Hot dip zinc galvanisation of Tubes & fittings used on OHE cantilever, Guide tube etc. shall be 800 gram/sqmtr as per A&C correction slip no.4 of ETI/OHE/13(4/84) or latest. 3.The price shall include the cost of supply of all components including galvanized steel tube duly fabricated and Porcelain insulators 1050/1600 mm CD as desired by open line) for polluted Zone (Id. 6000-1, 6030-1) including bolts, nuts etc. if any. 4.The price shall cover supply of all components including registered arm dropper for cantilever assembly as per latest RDSO drawing. 5.The price shall cover supply of double suspension clamp with thimble for anticreep centre. 6.The price shall cover supply of suspension clamp with thimble as per latest RDSO drawing. 7.All component should be as per latest RDSO specification and drawings, SMI, TI etc, 8.The price shall cover supply of RRA clamp must be with packing saddle as per drawing ETI/OHE/P/1370-1 rev-J or latest RDSO specification and drawings, SMI, TI. 9.The price shall include provision of packing saddle (RI No 1174) in catenary suspension clamp (RI No. 1160) as given in Modified drawing of suspension clamp (Drg. No. RE/33/P/1160 Rev K) as mandated vide RDSO MI No. TI/MI/0059 Dtd 05.09.24 (Drg. Attached in Annex II of above MI) 10.Composite insulators shall be used in polluted Zone and stone pelting areas with prior approval of Dy.CEE/C. 11. The price also covers cost for testing of insulator (ST/BT/9T) with Hydraulic insulator testing machine. Calibrated Insulator testing machine shall be arranged by contractor. 12.All Components shall have complied Latest RDSO/CORE specification. (Note: Forge type fittings shall be used instead of MCI wherever applicable.) Total 4914180.00 Item- 4 Supply of pull-off arrangement for OHE. S No. Item Description of Item Unit Qty Rate Amount No
The price shall cover supply of all components Each required for a pull-off arrangement to pull OHE equipment, including head span mast fittings complete with M.S. angle equalizing plate assembly steady arm, catenary dropper clip, contact wire swivel clip and fittings, including porcelain 9 ton insulators (1050mm CD) conductors, small jumpers (50 Sq.mm) wire. The price shall cover erection of all components including composite solid core insulators, small jumper wire and conductors. Total 54845.00 Item- 5 Supply of guy rod assembly S No. Item Description of Item Unit Qty Rate Amount No DYCEE-C-BRC-ELEC/WESTERN RLY
1.The price shall cover supply of guy rod Each assembly of various lengths for traction masts/portal upright complete with mast guy rod fittings, guy rod with adjustments and parts to be grouted etc in the anchor block including S.P.S. 2.The price shall not include the cost of supply of dwarf masts. 3.Galvanization shall be as per Railway Specification No. No. ETI/OHE/13(4/84) with C.S. No. 4 (05/2018) or latest with galvanization thickness of 1000 gram per sq. meter. 4.The price shall also cover the cost of supply of following components:- Railway ID No.Description of componentsQty/unit 3241,3251,3252,3291Mast Anchor Fitting for all type of structure1 No 3242 ,3231,3232Mast guy rod fitting with 4 sets of bolts of 20 mm dia of suitablelengthwithnuts,Locknuts,washersfor attachments to mast/S.P.S including appropriate fitting1 No 5001-3Stud bolts for draft mast (850mm)2 Nos. -Triangular attachment for Dwarf mast1 No 5002Guy rod stirrup1 Set 5004or5005or 5006.1 or 5070- 1Guy rod with nut, washer, split pin1 Set 5007- 1Anchor 'V' bolt1 Set 5008Anchor loop1 Set 5220-2, 5221,5222Guy rod double strap assembly.1 Set Note: All components should be as per latest RDSO Drawing and Specification with Revision (if any). Total 220300.00 Supply of regulating equipment 3 pulley type complete with all accessories including counter Item- 6 weight assembly and SS wire rope for conventional OHE as per RDSO Spec. TI/SPC/OHE/ATD/0060(Rev. 2) or latest for conventional OHE. S No. Item Description of Item Unit Qty Rate Amount No DYCEE-C-BRC-ELEC/WESTERN RLY
The price shall cover supply of regulating Each equipment 3 pulley type complete with all accessories including SS wire rope and counter weight assembly for 2000kgf tension including 9 Tonne adjuster & 9T Porcelain Insulator CD 1050 mm with double strap assembly, and normal/antitheft guide tube assembly (RI 5026- 4,5,6,7, 3076-4, 5, 6, 7) including supply of regulating equipment as per RDSO Specification No. TI/SPC/OHE/ATD/0060 Rev.-2 with latest A&C Slip or latest and stainless steel wire rope as per Rly Specification No. TI/SPC/OHE/WR/1060(06/2006) With A & C No.1, 2, 3 & 4 or latest, suitable for 3 Pulley ATD required for regulating equipment suitable for 2000kgf tension as per latest RDSO drawings & specification and small parts steel work, if any. The price shall also cover supply of anti-falling device (with extra fitting 3241 & 3243-01No. each), anti-climbing (stiffener) Angle on Anchoring, double eye distance rod with fasteners counter weight as per RDSO Drawing and mast fittings for all type mast. The price also covers cost for compliance of Latest Technical circular, MI/SMI's, Reliability action plan etc. (if applicable) Galvanization of all component shall be as per Railway Specification No. No. ETI/OHE/13(4/84) with C.S. No. 4 (05/2018) or latest with galvanization thickness of 1000 gram per sq. meter. Hot dip zinc galvanization of Guide tube shall be 800 gram/sqmtr as per A&C correction slip no.4 of ETI/OHE/13(4/84) or latest. The price shall cover the provision of pipe on Hex tie rod of ATD's as per RDSO MI No. TI/MI/0035 Rev-1 dt.28.09.2001 (or latest). The provision on Hex tie rod shall be on ATDs connected on Turnouts, X-overs, Neutral sections, other short tension lengths and tension length with FTA on other end. The length of pipe shall be as per procedure given in RDSO MI. The pipe shall be of 20mm dia GI, medium class as per IS 1161- 1979 (or latest). The ending clamp shall be installed correctly duly following instruction given in RDSO SMI No. TI/MI/0051 dt. 08.12.2017 (latest). Total 1019358.00 Item- 7 Supply of all types of GI bonds (40 X 6 mm) S No. Item Description of Item Unit Qty Rate Amount No DYCEE-C-BRC-ELEC/WESTERN RLY
1.The price shall cover for supply of all Each materials including GI flat 40 x 6 mm required to provide GI structure bond and other type of bonds to connecting a traction mast or structures to the nearest non track circuited rail, or earth electrode including all fasteners at both ends. The galvanization shall be done as per RDSO specification No. ETI/OHE/13(4/84) with C.S. No. 4 (05/2018) or latest ensuring quality of zinc, base metal, surface preparation. The weight of Zinc coating to be adopted is 750g/sqm. If galvanization is damaged due to hole drilling, welding, cutting, handling, erection etc. the rectification shall be done as per clause 8 of RDSO specification No. ETI/OHE/13(4/84) with ACS 1-4 (using zinc based solder/zinc based paints). 2.The price shall include shaping and drilling of the bond. 3.The price shall also include provision of heat shrinkable PVC sleeve & HDPE pipe as per latest guideline for structure bond under track circuited rail. Total 1096000.00 Item- 8 Supply of Earth electrode S No. Item Description of Item Unit Qty Rate Amount No
The price shall cover supply of an earth Each electrode assembly as per RDSO Drawing No.ETI/PSI/222 Rev-A & ETI/OHE/P/7021 or latest & RDSO specification No. TI/SPC/OHE/Fittings/0130 with A&C Slip No1, ETI-OHE-13 (4-84) may 2018, TI/SPC/OHE/Fittings/0130-10/13-Rev-1 with all accessories & fasteners for switching station of 4.00 mtrs length. The price also covers the provision of a protective concrete box with removable cover. Hot dip zinc galvanization of earth electrode tube shall be 800 gram/sqmtr as per A&C correction slip no.4 of ETI/OHE/13(4/84) or latest. Total 51900.00 Item- 9 Supply of GI flat for earth (50 X 6 mm) S No. Item Description of Item Unit Qty Rate Amount No
The price shall cover supply per meter length Metre of 50x 6 mm GI Flat. The galvanization shall be done as per RDSO specification No. No. ETI/OHE/13(4/84) with C.S. No. 4 (05/2018) and latest ensuring quality of zinc, base metal, surface preparation. The weight of Zinc coating to be adopted is 750g/sqm. If galvanization is damaged due to hole drilling, welding, cutting, handling, erection etc. the rectification shall be done as per clause 8 of RDSO specification No. ETI/OHE/13(4/84) with ACS 1 - 4 (using zinc- based solder/zinc based paints). The price also cover cost for supply of fasteners required for connecting the flat with earth bus. The price also covers cost for welding where ever required. Total 9750.00 Item- 10 Supply of Antibird disc on insulator end fitting S No. Item Description of Item Unit Qty Rate Amount No DYCEE-C-BRC-ELEC/WESTERN RLY
The price shall cover supply of Antibird disc on Each ST, BT & 9 ton insulators end fittings as per RDSO Drg No. TI/DRG/OHE/ABD/RDSO/00000/19/0 Rev.-I (Sh- 1 & 2) or latest, under RDSO MI No. TI/MI/00059 Rev 3 or latest. The disk shall be made up of polycarbonate of fire-flammability rating of V-2 or higher as per UL94, from Group 01, class 2 of latest from Group 01, Class 2 of ASTM D 3935-2, with additional properties as given in SMI. Material shall be procured from RDSO/CORE Approved vendor. Total 263580.00 Item- 11 Supply of Anti Monkey Climbing device (AMCD) as monkey scare for mast S No. Item Description of Item Unit Qty Rate Amount No
The price shall include supply and fabrication Each of Anti Monkey scare measure for OHE mast at Monkey menace prone areas as per RDSO SMI No. TI/MI/0056 Rev-2 or ltest. The AMCD shall be barbed wire frame type as per Drg no TI/SK/OHE/ANTIMON/RDSO/00001/08/0 given in Annexure I OR Cylindrical arrangement as per drawing given in Annexure II. Location and type of AMCD shall be jointly decided by SSE/Elect/Construction and SSE/TRD and approved by Sr.DEE/TRD. One sample for each type of OHE mast /Structure is to be fabricated and submitted to concern SSE for approval before utilization at site. Any modification suggested by concern SSE based on practical implication must be incorporated in the design. Total 652080.00 Item- 12 Supply of Anti Monkey Climbing device as monkey scare for Portal S No. Item Description of Item Unit Qty Rate Amount No
The price shall include supply and fabrication Each of Anti Monkey scare measure for OHE Portal/TTC at Monkey menace prone areas as per RDSO SMI No. TI/MI/0056 Rev-2 or latest. The AMCD shall be barbed wire frame type as per Drg no TI/SK/OHE/ANTIMON/RDSO/00001/08/0 given in Annexure l OR Cylindrical arrangement as per drawing given in Annexure II. Location and type of AMCD shall be jointly decided by SSE/Elect/Construction and SSE/TRD and approved by Sr.DEE/TRD. One sample for each type of OHE mast /Structure is to be fabricated and submitted to concern SSE for approval before utilization at site. Any modification suggested by concern SSE based on practical implication must be incorporated in the design. Total 145200.00 Supply of Nylon/plastic Net- High density polyethelene (HDPE) monofilament netting type-III, UV Item- 13 stabilized s per IS 16008(Part-2)-2016/PVC Virgin HDPE Net Preferably in black colour. S No. Item Description of Item Unit Qty Rate Amount No
The price shall include supply of Anti Bird high Sqm density poly ethelene (HDPE) filament netting type III, UV stabilized as per IS 16008 (Part-2)-
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .