| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.2 LAccepted-AOC VILL BARANGABARI PO KACHUBARI PS TAMULPUR DIST TAMULPUR PIN 781354 | KAMRUP | ASSAM | 781354 | L1 | Accepted-AOC Accepted Finance and Awarded the Work | |
| 2 | L2₹41.4 L+₹1.2 L (3.00%)Rejected-Finance | L2 | Rejected-Finance Financially Rejected | |
| 3 | Rejected-Technical | - | Rejected-Technical Technically Dis-Qualified as the bidder not deposited the requisite EMD. |
Tender Value
₹40.2 L
EMD Value
₹80,380
Closing Date
9 Mar 2023, 2:00 pmClosed
Block Development Officer, GDB
Block Development Officer, Goreswar Development Block, Dist - Baksa, BTC, Assam
Construction of Bodoland Co-Operative Thrift and Credit Society Ltd (1st Floor only) Salbari under Jalah Development Block.
2023_BoTC_29606_1
GDB/SOPD/WPT and BC/51/2019-20/2136
Open Tender
Civil Works - Building
Works
180 days
Salbari under Jalah Development Block
Please refer Tender documents.
5 documents required · 5 mandatory
₹805
₹80,380
Yes
5 Mar 2024
28 Feb 2023
9 Mar 2023
28 Feb 2023
9 Mar 2023
28 Feb 2023
28 Feb 2023 - 4 Mar 2023
CONSTRUCTION OF BODOLAND CO-OPERATIVE THRIFT AND CREDIT SOCIETY LTD(1ST FLOOR ONLY), SALBARI, BAKSA DISTRICT UNDER WPT & BC FOR THE YEAR 2022-23
Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 5.22A.6Thermo-Mechanically Treated(TMT) bars of grade Fe-500 or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.1 Mild steel and Medium Tensile steel bars.
Centering and shuttering including strutting, propping etc. and removal of form for: 5.9.6 columns, pillars, piers, Abutments, posts abd struts.
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Suspended Floors, roofs, landings, balconies and access platform Slab.
5.9.3 Stairs, (excluding landings) except spiral staircases.
Reiforcement cement concrete work in wall (any thickness), including attached plester, buttresses, plinth and string courses, fillets, columns,pillers,piers,abutments,post and struts etc. above plinth level up to floor levle, excluding cost of cetering,shuttering, finidhed and reinforcement.5.2.2 1:1:5:3 (1 cement: 1.5 coarse sand (zone-III) : 3graded stone aggregate 20mm nominal size)
Reiforcement cement concrete work in beams, suspended floors, roofs having slope up to 15' landings balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1:.5:3( 1 cement: 1.5coarse sand (zone III: 3 graded stone aggregate 20 mm nominal size).
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :6.12.2 cement mortar 1:4 (1 cement : 4 coarse sand)
Providing wood work in frames of doors,windows, clerestory windows and other frames wrongth framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) 9.1.1 Second Class teak wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately all complete as par direction of Engineer in charge.(Note:- butt hinges and necessary screws shall be paid separately)9.5.1 Second class teak wood. 9.5.1.1 35mm thick shutters.
Providing and fixing panelling or panelling and glazing panelled or panelled and glazed shutters for doors, windows and clerestory windows(Area of opaning for panel inserts excluding portion inside grooves or rebates to be measured) panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thiek: 9.7.1 second class teak wood
Providing and fixing glazwd shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary serews, 9.9.1 Second class teak wood 9.9.1.1 35mm thick
Providing and fixing factory made uPVC door frame made of uPVC extruded sectiots having an overall dimension as below (tolerance ± 1 mm), with wall thickness 2.0 mm ± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded.The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as p r manufacturer's specification and direction of Engineerin-charge. 9.117.1 Extruded section profile size 48x40 mm
Providing and fixing to existing door frames. 9.118.124 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuift edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (t 0.1 mm) wall thickness. The lock rail made up of H section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the hutter styles by means of plastic/galvanised M.S. 'U' cleats. The shuttr frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness.The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter).
12 mm cement plaster of mix : 13.4.21:6 (1 cement: 6 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix: 13.5.21:6 (1 cement: 6 coarse sand)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square of round bars etc. including priming coat with approved steel primer all comple etc. 9.48.1 Fixed steel windows by welding.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and confirming to IS:15622, of approved make, in all colours and shades, laid on 20mm thick cement morter 1:4 (1 cement : 4 sand), jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. complete. 11.41.2 Size of Tile 600 x 600mm
Providing and laying rectified Glazed Cderamic floor tiles of size 300x300 mm or more(thickness to be specified by the manufacturer), of 1st quality conforming to IS:15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement morter 1:4 (1cement: 4 Coarse sand), jointing with ge=rey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. complete.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-In-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3,3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Distempering with oil bound washable distemper of approved brand and manufacture to 13.41 give an even shade: 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer
Painting walls with water proofing cement paint of required shade: 13:44.1 New work (Two or more coats applied @ 3.84 kg/10sqm)
Applying priming coat: 13.50.1 With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 13.62.1 Two or more coats on new work over an under coat of suitable shade with with ordinary paint of approved brand manufacture.
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodio coating not less than grade AC-10 as per IS 1868) transperent or dyed to required colour or shade, with nuts and screws etc. complete.
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete.
Providing and fixing aluminium handles, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transperent or dyed to required colour or shade, with necessary screws etc. complete.
Sanitary and Water supply Work.
Construction of septic tanks (Detailed Estimate enclosed) 50 Users
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid,10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 17.2.1 W.C. pan with ISi marked white solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P.brass pillar lapseach 3087.70
Providing and fixing mirror of superior glass (of approved quality) and ofrequired shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 17.32.2Rectangular shape 453x357 mm.
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm,height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP bn;1S61'crews with concealed fittings arrangement of approved qualJtyand colour. 17.73.1 450 mm long towel rail with total length of495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms.
Providing and Fixing Soil waste and vent pipes 17.35.1 100 mm dai 17.35.1 1 sand cast iron pipe as par IS: 1729
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 19.32.1With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Water Supply Works.
Boring with 100 mm diameter casin pipe for hand pump / tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand Rm pump / tube well is lowered and tested : 18.42.3Beyond 12 m and up to 18 m depih.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply iluding all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 18.9.7 62.50 mm nominal inner dia Pipes.
Providing and placing in position filters of 40 mm diameter G.I. pipe with brass strainer of approved quality.
Development of tube well in accordance with IS:2800 (Part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor, for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, I/C disinfaction of tubewell, all complete, tools & accessories etc. all as per requirement and direction of Engineer-in-Charge.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and tuitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cementand testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 18.7.5 40mm nominal outer dia pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 18.8.3 25mm nimina outer dia pipes.
18.8.1 15mm nimina outer dia pipes.
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS 8931. 18.52.115 mm nominal bore.
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 18.49.115 mm nominal bore
INTERNAL ELECTRIFICATION WORK A. WIRING.
Wairing for light point/fan point/exhaust fan point/call bell point with 1.5 sq. mm FRLS PVC insulated copper conductar single core cable in surface/ recessed iaminated sheet, suitable size MS box and earrhing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc. as reqired. 1.1.1 Grup A
1.1.2 Group B
1.1.3 Group C point 1191
Wiring for light/power piug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit along with 1 no. 4sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single cor cable in surface/recessed steel conduit as required. 1.7.1.2 X 1.5 sq mm + 1X 1.5 sq. mm earth wire (circuit wiring)
1.7.2 2 X 2.5 sq. mm + 1X 2.5 sq. mm earth wire (submain wiring)
B. SWITCH/SOCKET/PLATE ETC.
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.4 3 pin 5/6 A socket outlet
1.24.5 3 pin 5/6 A socket outlet each 175
Supplying and fixing metal box of following sizes (normal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required 1.22.3 150 mm X 75 mm X 60 mm deep.
1.22.14 200 mm X 300 mm X 100 mm deep.
C. FITTING & FIXTURES.
Supplying and fixing brass batten/angle holder including connection etc. as required.
D. EARTHING.
Earthing with G.I. earth pipe 4.5 meter long , 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for coductor earth electrode, including connection/ termination with GI thimble etc. as required.
E. MCB/MCBDB/RCCB ETC.
Supplying and fixing following way, single pole and neutral, sheet steel,MCB distribution board , 240 V, on surface /recess, complete with tinned copper bus bar, interconnection, powder painted incluging earthing etc. as required. (But without MCB/RCCB/Isolator) 2.3.3 12 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution bord, 415 V, onsurface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnection, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator) 2.4.1 4 way (4+12) Double door
Supplying and fixing following rating , double pope, 240 V, inolator in the existing MCB DB complete with connection, testing and commissioning etc. as required. 2.12.2 63A
F. PANEL BOARD.
Supplying and fixing following rating four pope,(three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivety current 30 mA in this existing MCB DB complete with connections, testing and commissioning etc. as required. 2015.3 63A
Construction of Approach Road
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc. of required strength, thickness for size/shape, made by table vibratory method using PU mould, laid in required colour or pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver bloscks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as per direction of Engineer-In-Charge. 16.91.2 80 mm thick C.C. paver block of M-30 grade with approved colour design and pattern.
CONTINGENCY
Add Contingency.
MISS MAYABATI BRAHMA
MISS MAYABATI BRAHMA
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .