Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹1.5 Cr
EMD Value
₹3.0 L
Closing Date
30 Dec 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AS PER THE NIT
AS PER THE NIT
Roofing of Store Block / Pump House and Connection of Store with Existing Hospital at SKIMS MCH Bemina Srinagar
2025_PWDJK_298888_1
NIT No 55/EE/RnB/BM/CS/7262-70 of 2025-26 DATED 22.12.2025
Open Tender
Civil Works
Percentage
180 days
AS PER THE NIT
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,600
AS PER THE NIT
₹3.0 L
22 Dec 2025
22 Dec 2025
31 Dec 2025
23 Dec 2025
30 Dec 2025
23 Dec 2025
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
Providing and fixing hib rib colour coated sheets of 0.5 mm thickness for roofing including hook bolts and nuts of 8 mm dia or PVC limpet washers complete upto any pitch in horizontal/vertical or curved surfaces including ridges/hips or valleys of 60cm overall width of plain precoated sheets wherever required complete
Clearance of site including shifting of utilities pipes cables etc complete job. By way of labours
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: all kinds of soil lead upto 25 mtrs. beyond 1 m from cutting edge.
Providing and laying dry stone soling hand packed in bed incl. Ramming, compacting dressing complete incl. All leads, lifts, head loads and all carriages involved complete.
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). Incl. all leads, lifts , head loads and all carriages of material involved complete.
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) incl. all lead, lifts, head loads and all carriages of all material involved complete.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) incl. all lead, lifts, head loads and all carriages of all material involved complete.
Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns etc for mass concrete.
Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) :
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Painting steel work with deluxe multi surface paint of required shade to give an even shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.80litre/10sqm of approved brand and manufacture.
Electrical
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc. as required
Group A
ceiling roase
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed mecium class PVC conduit as required
2x2.5 sqmm + 1 x 2.5 sqmm earth wire (in minimum 20mm)
2x4 sqmm + 1 x 4 sqmm earth wire (in minimum 20mm)
2x6 sqmm + 1 x 6 sqmm earth wire (in minimum 25mm)
2x10 sqmm + 1 x 6 sqmm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fizing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch connections etc. as required.
Supplying and Fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and Fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc as required.
Supplying and fizing following way, horizontal type three pole and neutral, sheet steel, MCB ontribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. But without MCB/RCCB/Isolator)
6 way (4+18), Double door
Supplying and fixing 5 A to 32 A rating 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required
Single Pole
Double Pole
Plastic Box for MCB 2 way
Supplying and fixing following rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following size/ modules, Gl box alongwith modular base &cover plate for modular switches in recess etc. as required.
4 Module (125mm x 75m)
6 Module (200mm x 75mm)
8 module (125mm x 125mm)
12 module (200mm x 150mm)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/coke and salt as required
Providing and fixing 25 mm X 5 mm G.L. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required
Supply, Installation, Testing and Commissioning of 1200 mm sweep, Ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos, canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS 374-2019), THD less than 10%, remote or Electronic Regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulationresistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
4 feet long hatten 6000/6500k Light having extruded alumlulum lovat stnk with anti glare diffuser with energy efficient electronic driver CRI greater than 80 with mhulmunt sytem lumens 2000 and maximum wattage 20 incitaling connection with multistrand copper conductor 3 cure cable ete as required at sitewith burning hours greater than 50000 Hour's having system lumens 110 Lam/watt
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders both sides (IN & OUT put) in existing cubicir Panel board including drilling holes in cubicle pannel, making connections, ele, as required. 100A, 25 ΚΑ, TPMCCB.
Supplying, Installation, testing and commissioning of factory assembled sheet steel clad powdercoated, stand mounting cubicle board made from 1.6mm thick CIRCA sheet dust and vrrimin proof dully phosphatized and powder coated out door type 3 phase neutral LTpanel Providing with hinged gasketted door padlocking facility and including suitably rated PVC Insulated Inos of 4 strip Aluminiunt bus bar complete with Interconnections, providing lugs, earthing terminals, stand as per site requirement rie Complete with P/F of sultable size of angle iron stand with painted as per site requirement. FRONT OPERATED PANEL
Providing of 3 ½ core XLPE AL, cable Armored of 50 sqmm fresh ones. 1.1KV from Main MCCB 200A to newly to be installed main LT Panel to be Installed at IPD. The job Includes the cost of fixing of above one number PVC Insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of 50 SQMM, cable 3.5 core stze on wall surface (clamped with 40x3mm MS flat clamp) as per site requirement.50MM 3.5 core.
Supplying and making end termination with brass compression gland and aluntintum lugs for 3 1/2 X 50sq. mm (45mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3 1/2 x 50 sqmm (35mm).
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of 3 1/2 core XLPE AI. cable Armored of 50 sq.mm size on cable tray as required. Upto 50 sq. mm (clamped with 1mm thick saddle).
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.70 MB
BOQ_969317.xls
BOQ • 0.54 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .