Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.5 LAccepted-AOC VILL SIMALGURI P O BALLAMGAURI P S BIJNI DIST CHIRANG BTC ASSAM | CHIRANG | ASSAM | ₹61.5 L | L1 | Accepted-AOC L1 |
| 2 | L2₹62.0 L+₹57,486.94 (0.94%)Rejected-AOC | ₹62.0 L+₹57,486.94 (0.94%) | L2 | Rejected-AOC L2 |
| 3 | L3₹62.2 L+₹74,720.03 (1.22%)Rejected-AOC | ₹62.2 L+₹74,720.03 (1.22%) | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
18 Jan 2021, 4:30 pmClosed
Addl. Chief Engineer cum Director, PWD, BTC, Koj
O/o the Addl. Chief Engineer cum Director, PWD, BTC, Kokrajhar
Construction of Boundary wall, iron gate, earth filling, toilet block, kitchen and car parking at Ultapani Cultural Research Centre, Kokrajhar.
2021_BTC_19881_1
ACE-27/TECH/KOJ/IFB/2016-17
Open Tender
Civil Works
Item Rate
180 days
Kokrajhar
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,850
Principal Secretary, BTC, Kokrajhar
₹1.2 L
Yes
12 Sept 2022
2 Jan 2021
19 Jan 2021
2 Jan 2021
18 Jan 2021
2 Jan 2021
2 Jan 2021 - 18 Jan 2021
Amount
BOUNDARY WALL 1.1. Earth work in excavation for foundation trenches of walls, retaining wall, footing of column,………….. As directed and specified. (A) Up to a depth of 2m below the existing G.L. (a) In ordinary soil.
4.1.1. Providng soling in foundation and under floor with stone quality picked……………..dewatering, complete. (a) Brick on flat soiling.
2.1.1. Plain cement concrete works with coarse aggregate of size 13mm to 32mm in foundation bed, and curing………..complete. (b) In prop. 1 cement : 4 sand : 8 coarse aggregate by volume.
18.1.1. Supplying fitting and fixing in position reinforcement bars Conforming to relevent IS code for..........spacers etc. complete (upto 1st floor level). (b) Other I.S.I. approved TMT bars. SAIL/BISCON/THERMAX 8mm dia col. Jalli
(c ) ISI approved MS road, 6mm dia,
3.2.1. Providing form work of 12mm thick plywood board so as to give a situ reinforced concrete and plain concrete work in: 3.2.1.1. Column, pillars, post & strut of square/rectangular/polygonal in plan or any shape like Tee/L etc. having plane vertical face.
3.1.1.2. Sides and soallits of beam, beam hanching, cantilever girders, bressumers, linters and horizontal ties. (a) For depth not exceeding 1.0 M
2.2.1. Providing and laying plain/reinforcement cement concrete work in Prop. 1:2:4 (1 cement : 2 coarse sand : 4 graded………… and paid separately) (I) Using mixture machine. (A) In sub-structure up to plinth level.
(b) In substructure from P.L. up to 1st floor level etc. (a) Using mixture machine.
4.1.4. Brick work In cement mortar with 1st class brick incl. racking out structure up to plinth level. (c ) In prop. 1:5
2.1.3. Providing and laying 25mm thick damp roof course with Cement concrete in prop. 1:1.5:3 with graded stone agg………… complete as directed.
4.1.8. 1st class brick nogged wall in cement mortar including racking………………. Paid separately. (A) 112mm thick wall (b) In cement mortar in proportion 1:5 (1 cement : 5 sand)
6.2.2. 15mm thick cement plaster in single coat on rough side of single or Half………… exceeding 80mm in curing complete as directed. (b) In cement mortar 1:4
13.2.3. (a) Applying one coat of cement primer of approved brand and manufacture on …………... surface even and sand papered smooth.
(b) Finishing wall with water proofing cement paint of approved brand removal all dirt and remains of loose powdered materials.
IRON GATE 1.1. Earth work in excavation for foundation trenches of walls, retaining wall, septic tank, footing of columns, step including, refilling, return filling the quantity………….. (A) Within a depth upto 2.00m below the existing G.L. (a) In Ordinary soil.
4.1. Providing soling in foundation and under floor at all levels with stone best quality picket jhama bricks………. (a) brick flat soling
2.1.1. Plain cement concrete work with coarse aggregate of size 30mm to 32mm in foundation bed …………… (b) In prop. 1:4:8
18.1.1. Supplying, fitting and fixing in position reinforcements bars………. (b) Other ISI approved TMT bars
3.2.1. Providing form work of 12mm thick ply wood ………. 3.2.1.1. Column, Pillars, posts & Struts of squre/rectangular/polygonal in plan or any shape like Tee/L etc. having plane vertical face.Post, Upto plinth , Above plinth
3.2.1.2. Sides and soffits of beam, beam hunchings contiliver, tie……….. (a) Depth not exceeding 1.00m……….
3.2.1.3. Flat surface such as soffit of suspended floor, roof landing. (a) Floors etc. upto 200mm thickness.
2.2.1. Providing and laying plinth/reinforcement cement concrete works with coarse agg. 20mm down………… (I) Using mixer Machine. (a) In sub-structure upto plinth level. Foundation, footing, column with base, tie and plinth beam. (N) Without using admixture, plaster (a) M15 prop. 1:2:4
(b) In super-structure upto 1st floor level. (ii) Column, pillar,post structure………….. (N) Without using admixture, plasticiser. (a) M15 prop. 1:2:4
6.2.2. 15 mm thick cement plaster in single coat on rough side of single or half brick wall for interior plastrering………. (b) In cement mortar 1:4
17.12. Supplying fitting and fixing double leaf heavy duty iron gate frame made of 40mm X 40mm X 6mm M.S. flat angle
17.13 providing Rails for playing runner
17.14. Providing roller to the gate………….. (a) 25mm X 50mm dia roller
Painting of iron grill and P.C.C. surface……………..
Earth Filling 1.4. Raising low site around the building with approved soil obtained from outside truck carriage including Breaking clods, dressing, etc. Complete including paying necessary with payment of land (b) Other than Guwahati city.
TOILET AND URINAL 1.1 Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil.
4.1.1 Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume
3.1.1. Providing formwork of ordinary timber planking so as to give a rough finish including centering, shuttring, shuttring and propping etc… 3.1.1.1. Foundation, footing, bases of columns pile cap, raft and mass concrete work etc. (b) Using 25mm thick plank.
3.1.1.2. Sides of tie beams, grade beams etc. at or below ground level. (b) Using 25mm thick plank
3.1.1.3. Columns, Pillars, Posts & Strut (b) Using 25mm thick plank
3.1.1.4. Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (b) Using 25mm thick plank
4.1.4. Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary (b) In proportion 1:4.
1.2. Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc.complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (a) With earth or silt or sand obtained by head load with lead upto 90m and lift upto 2m
4.1.8. 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protuding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (b) In cement mortar in proportion 1:5.
6.2.2. 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side c) In cement mortar 1:5
B) On fair side c) In cement mortar 1:5
12.4. Providing fitting and fixing PVC Door shutters of Duroplast DPS-3720 made from extruded PVC stiles and rails….all levels B) With 1st class local wood (ii) 35mm thick
13.2.3. a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
13.5.1. Applying one self/priming coat of acrylic cmulsion coating of Unicem "Rakshak" brand by thinning 1 ltrs of paints with 1 ltrs of water over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even ans sand papered smooth as specified and directed by the
13.4. Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a). Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
13.6.3. Applying priming coat over new wood and based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter sand papering and knotting. (a) With ready mixed paint, Wood primer (pink)
13.6.5. Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter sand papering and stopping. (i) Surfaces over 100mm in width or girth. a) General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
18.3.1. Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. b) Using other ISI marked approved circular hollow section
8.1.1. Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE / SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8mm dia with bitumen washer 25 mm dia x 3 mm thick and 1.6 mm thick limpet washer complete excluding cost of roof truss, purlin etc. (Roof trusses and purlin etc. to be measured and paid separately). (c) 0.55 mm thick
8.1.3. Labour for fitting and fixing Galvd corrugated iron roofing including supplying and fixing with new galvd screw, J hook, bolts nuts, washer etc. complete as directed.
5.7.1.1. Providing ceramic tiles of approved quality of specified size, shapeand thickness not less than 8 mm on floors, skirting, risers and treadsof steps over 15 mm thick base of cement mortar in prop 1:3………as approved and directed by the Department. a) Normal range (Somany/Orient/Nitco/Asian/ Make ii) Of size 400mm x 400mm and above toilet and urinal verandah stairs
5.7.1.2. Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10mm thick in prop 1:3………as specified and directed a) Normal Range (Somany/Orient/Nitco/Asian Make) i) Of size 200mm x 200mm and above
5.1.10. Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15 mm thick
2.2.1. Providing and laying plain/reinforced cement croncrete works cement. Coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (A) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. b) M20 grade concrete or Prop. 1:1.5:3
(b) In super-structure upto 1st floor level. a) M20 grade concrete or Prop. 1:1.5:3
18.1.1. Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works, retaining wall & boundary wall etc.
19.1. Providing plinth protection 50mm thick to cement concrete 1 : 3 : 6 with coarse agg. Of 20mm nominal size including finishing the surface with 10mm thick cement plaster in proportion 1:3 with a floting coat of neat cement finished.
15.3.1. Supplying, fitting, fixing brass fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary C.P. brass screws etc. Complete. (Bright natural matt & satin finished) (A) Sliding door bolt (ii) 250mm X 16mm
(B) Tower bolt (i) 300mm X 10mm
(c ) Door handles (ii) 100mm
26.1.1 Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
19.5 Providing drain with brick work in cement mortar in prop. 1:5 with half brick thick side walls and 100 mm thick CC (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessry shttering for sides and earth work in excavation of foundation trenches and refilling the sides after complete of work etc. as specified. (ii) 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
2.1.3. Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
2.1.4. Plain cement concrete apron in prop 1:4:8 with 20mm down graded coarse agg. Over soling including neat cement finish using cement slurry 2.75 Kg. of cement per Sqm of floor (soling to be measured separately) (b) 50mm thick
5.11. Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick 1:3 Vitrified Durastone (Unpolished heavy duty vitrified tiles
INTERNAL WATER SUPPLY 3.1.2. Supplying fitting and fixing approved uPVC pipes of different sizes, with all necessary "R" brand or similar approved P.V.C. fittings such as bend, tee, elbow, reducer, nipple, plug, long screw, clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed or in trenches (d) 25mm dia
3.2.1. Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. Jaquare make. (ii) Bibcock long thread.
3.8.1. Supplying fitting and fixing overhead adjustable Chrome Plated (C.P.) spray shower 15mm dia. Of sona make with wall flanga as directed and specified. (Pipes will be measured and paid separately) (b) Apex/Kiran/Priya/Star/RimZim/Bugle shower with arm
3.3.1. Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and (iii) 25mm dia
3.6.1. Supplying fitting anf fixing Chrome Plated (C.P.) sink cock of approved brand as directed and Agmeco brand (b) Sink cock two way
EXTERNAL WATER SUPPLY 5.1.1. Supplying fitting and fixing pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc. complete as directed (iv) 32mm diameter
(iii) 25mm diameter
1.5. Supplying, fitting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standared size CP flush pipe, union clamps etc. complete as directed and specified (pipes will be measured separately) (i) Parryware make (ii) Deluxe Single Flush
1.8. Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader and brass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. (i) Parryware make (i) New Magnum
1.13. Providing vitreous China wash basin with CI/MS brackets, C.P. brass chain with plug, PVC waste PEDESTAL BASIN (with pedestal) (ii) Vanice 620 X 485 X850 (Cat. No. C841 P/R) (White/coloured)
KITCHEN AND DINING ROOM 1.1 Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling(return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. A) Upto a depth of 2.00m below the existing ground level. i) In ordinary soil
4.1.1 Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume
3.1.1 Providing form-work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc........ 3.1.1.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (i) Using 25mm thick plank
3.1.1.2 Sides of tie beams, grade beams etc. at or below ground level. (b) Using 25mm thick plank
3.1.1.3. Columns, Pillar, Posts & Strut (b) Using 25mm thick plank
3.1.1.4. Sides and soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (b) Using 25mm thick plank
4.1.4. Brick work in cement mortar with 1st class brick incl. racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary (b) In proportion 1:4
1.3. Earth/sand filling in plinth layers not more than 150mm thick including necessary carriage, watering, remming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With earth or silt or sand obtained by head load with lead upto 90m and lift upto 2m
4.1.8. 1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S. rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick Brick wall b) In cement mortar in proportion 1:5
6.2.2. 15mm thick cement plastering in single coat on single or half brick wall for interior plasrering up to 1st Floor level including arises, internal rounded angles not exeeding 80mm girth and finished even and smooth including curing complete as directed. (A) On rough side (b) In cement morter 1:5
(B) On fair side (c ) In cement mortar 1:5
9.1.2. Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (b) With sal wood
9.9.2 Providing, fitting and fixing full panelled doors/ windows including oxidised M.S butt hinges (100mm x75 mm x3.55mm) with necessary screws (other fittings to be measured and paid separately ) B) With 1st class local wood (ii) 35mm thick
13.2.3 a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
13.5.1. Applying one self-priming coat of acrylic emulsion coating of Unicem "Rakshak" brand by thinning 1 ltrs of paints with 1 ltrs of water over freshly plastered wall surface after throughly brooming the surface free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the
13.4.1 Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a) Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
13.6.3 Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. (b). With ready mixed paint , wood primer (white).
13.6.5 Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. i) Surfaces over 100mm in width or girth. b) High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
18.3.1. Providing fitting, hoisting and fitting of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawings as dierected. (b) Usingh other ISI marked approved circular hollow section.
8.1.1. Providing corrugated galved iron sheet roofting of TATA shaktee/SAIL incl. fitting and fixing necessary Galvenised J or L hooks, bolts and nuts 8mm dia with bitumen washer 25,, dia X 3mm thick and 1.6mm thick limpet washer complete excluding cost of roof truss, purlin etc. (Roof trusses and purlin etc. to be measured and paid separately). (D) 0.55mm thick,
8.1.2. Providing galvd iron ridging of TATA SHAKTEE/SAIL including supplying and fixing necessary galvd screws/washers etc. complete as directed. (C ) 0.55mm thick (ii) 230mm lapping
8.1.3. Labour for fitting and fixing Galvd corrugated iron roofing including supplying and fixing with new galvd screw, J hook, bolts nuts, washer etc. complete as directed.
5.1.4. Providing Vitrified floor tiles of approvedquality of specified size, shapeand thickness not less than 18mm on floors, skirting, risers and treadsof steps over 15mm thick base of cement mortar in prop 1:3…. As approved and directed by the Department. (a) Normal rang (Somany/Orient/Nitco/Varmora/Vita/Marbito/Make (ii) Of size 600mm X 600mm
5.1.10 cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions withfloor. a) 15mm thick.
2.2.1 Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (A) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. b) M20 grade concrete or Prop. 1:1.5:3
(b) In super structure from plinth level up to 1st floor level. (a) M20 grade concrete or Prop. 1:1.5:3
7.10.1. Providing fitting and fixing in position suspended false ceiling using E-Grid (exposed ceiling suspension 2430 system) of grid size 600mm X 600mm/1200mm X 600mm with main runner 38 X 24mm, cross tee 29mm X 24mm & wall angle 24mm X 24mm. Using 4mm/6mm thick High Pressure Steam Cured Non Asbestos Fibre Cement Board as per IS 14862, to be placed in a grid of G.I. system duly suspended with 4mm/6mm dia G.I./M.S. bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light............etc. (A) Standard Ceiling of Everest make or equivalent as directed by the department. (i) Using 6mm thick FC Board
18.1.1. Supplying fitting and fixing in position reinforcwement bars conforming to relevant I.S. code for RCC work/R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are including in the rate ) (Upto 1st floor level). (b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works, retaining wall & boundary wall etc.
19.1. Providing plinth protection 50mm thick to cement concrete 1:3:6 with coarse agg. Of 20mm nominal size including finishing the surface with 10mm thick cement plaster in proportion 1:3 with a floting coat of neat cement finished.
15.3.1. Supplying, fitting, fixing brass fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary C.P. brass screws etc. Complete. (Bright natural matt & satin finished) (A) Sliding door bolt (ii) 250mm X 16mm
B) Tower Bolt (i) 300mm X 10mm
(c ) Door handles (ii) 100mm
(D) Gate shutter hook & eye (iii) 250mm
10.2. Providing, fitting and fixing M.S. grill of required pattern for windows/clerestory windows/ opening with M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. I. Plain grill (a) Fixed to wooden frames
26.1.1 Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
19.5 Providing drain with brick work in cement mortar in prop. 1:5 with half brick thick side walls and 100 mm thick CC (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. (ii) 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm
2.1.3. Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
2.1.4. Plain cement concrete apron in prop 1:4:8 with 20mm down graded coarse agg. Over soling including neat cement finish using cement slurry 2.75Kg. Of cement per sq.m. of floor (soling to be measured separately). B) 50mm thick
5.10.1. Providing poished granite tiles of approved quality, size and shap and thickness not less than 8mm, on walls over 15mm thick, cement mortar bed in prop. 1:3…., complete at all levels as specified and directed.
5.11.2. Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick 1:3 Vitrified (i) Normal range (Size 300mm X 300mm Somany made-Durastone (Unpolished heavy duty vitrified tiles (a) Premium
CAR PARKING 1.1. Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
4.1.1. Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling.
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1 cement : 3 sand : 6 coarse aggregate by volume
3.1.1. Providing formwork of 12 mm thick plywood Board so as to given a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in : 3.2.1.1. Columsn, Pillars, Posts & Strut of square/ rectangular /polygonal in plain or any shape like Tee/L etc. having plane vertical face (b) Using 25mm thick plank
3.2.1.2. Sides and Soffits of beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.
4.1.4. Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary (b) In proportion 1:5.
2.2.1. Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded (A) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1.5:3
(B) In super structure from plinth level up to 1st floor level. (b) M20 grade concrete or Prop. 1:1, 5:3
1.2. Earth/sand filling in plinth in layers not more than 150mm thick including necessary carriage watering. ( c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading .
4.1.8. 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed (A) 112mm thick brick wall (b) In cement mortal in proportion 1:5.
6.2.2. 15 mm thick Cement plaster in single coat on single or half brick wall for interior plasering up to 1st c) In cement mortar 1:4
13.4.1. a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to given and even shade after thoroughly brooming the surface to remove all dirt and remains of loose powdered materials.
18.3.1. Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. a) TATA make Circular Hollow section-CHS of Grade YST-310 conforming to I.S.
8.1.1. Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE /SAIL including fitting and ( C) 0.50 mm thick
18.1.1. Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX)
2.1.4. Plain cement concrete apron in prop 1:4:8 with 20mm down graded coarse agg. Over soling including neat cement finish using cement slurry 2.75Kg. Of cement per sq.m. of floor (soling to be measured separately). B) 50mm thick
5.11.1. Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick 1:3 Vitrified i) Normal range (Sizes 300mm x 300mm and above Somany made-Durastone (Unpolished heavy duty vitrified tiles a) Premium
16/18.4.2. Providing and fixing rolling shutters of approved make made of 80mm wide M.S. laths interlocked together through their entire lenth and jointed together at the ends by end locks mounted on specially designed pipe shaft with bracket plates, guide channels and arrangements for inside and outside locking with push-pull operation complete including cost of wire, spring and hood cover for shutters.
SEPTIC TANK 1/1.1. Earth work in excavation for for foundation trences of wall retaining wall of septic tank footing of column, steps including, refilling, return filling the quantity ………………………. (A) Within a depth upto 2.00 m below the existing G.L. a) In Ordinary soil.
4.1. Providing soling in foundation and under floor at all level stone best quality picked jhama brick, sand. (a) Brick on flat soling.
2.1.1. Plain cement concrete works with coarse agg. Of size 13mm to 32mm in foundation bed………. (b) In prop. 1:4:8
18.1.1. Supplying fitting and fixing in position, reinforcement bars…. (b) Other ISI….
4.1.4. Brick work in cement mortar with 1st class brick including racking out joint and curing complete……… (b) In prop.1:4
2.2.1. Providing and laying plinth/reinforcement cement concrete works with coarse agg. 20mm down………… (I) Using mixer Machine. (a) In sub-structure upto plinth level. Foundation, footing, column with base, tie and plinth beam. (N) Without using admixture, plaster (a) M15 prop. 1:2:4
25.12. Providing precast RCC lab over drain, septic tank etc. in prop. 1:2:4 reinforced with 10mm TMT/HYSD bar @ 150mm centre both way tying with necessary shuttering, curing etc. Complete including fixing in position as directed. (a) 75mm thick slab
6.2.2. 15 mm thick Cement plaster in single coat of single or half brick wall for interior plastering …………. A) On rough side b) In cement mortar 1:4
1.51. Construction of filter bed in soak pit including earth….
WATER SUPPLY WITH DTW BORING 5.3.4. Labour for boring hole for inserting tube well through the difference soil/Rock media… (iv) 150mm dia
5.3.5. Supplying, fitting and fixing pipes plain/bevel ended for casing conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole (ii) PVC PIPE SUPREME/PRINCE/FUSION/SFMC Brand (v) 10mm dia
5.3.6. Supplying, fitting, and fixing suction pipes plain/bevel ended for casing, conforming to relevent IS codes of practice…... (a) TATA/SAIL (Medium) socket should be welded to the pipes. (iv) 50mm diameter
5.3.7. Supplying fitting and fixing G.I. filter 2.00m long
5.3.11. Supplying fitting and fixing check valve including thread to pipes… (e) 50mm dia
5.3.13. Fiushing clearing washing and watering the tube well………
390 Elect. Supplying including installation of open well submersible type water supply motor pump set….. (2) 1.5 HP single Phase.
Supplying and placing plastic cylindrical vertical clausesd top (PCVC) tank of Sintex/Polycon/Patton make over the stagging with manhole cover with (ii) 1000 liter capacity
3.1.2. Supplying fitting and fixing approved UPVC pipes of different size with all necessary R, brand or similar approved PVC….. (A) Exposed or in trenches. (Supreme/Prince/SFMC brand) (a) 50mm dia
(b) 40mm dia
RCC Stage for Placing water Tank 1.1. Earth work in excavation for foundation trences of wall retaining wall of septic tank, footing of column, steps including, refilling, return filling the quantity…………. (A) Within a depth upto 2.00m below the existing G.L. (a) In ordinary soil.
4.1. Providing soling in foundation and under floor at all levels with stone best quality picket jhama bricks………. (a) brick flat soling
2.1.1. Plain cement concrete works with coarse agg. Of size 13mm to 32mm in foundation bed……… (b) In prop. 1:4:8
18.1.1. Supplying fitting and fixing in position, reinforcement bars…. (b) Other ISI approved TMT bars
3.2.1. Providing form work of 12mm thick plywood board …………………. 3.2.1.1. Column, pillars, post & strut ……………… Square, rectangular
3.1.3. Sides and soffits of beam, beam hunching, cantilever… (a) Depth not exceeding 1.00m…..
3.2.1.3. Flat surfaces……….
2.2.1. Providing and laying plinth/reinforcement cement concrete works with coarse agg. 20mm down………… (I) Using mixer Machine. (a) In sub-structure upto plinth level. Foundation, footing, column with base, tie and plinth beam. (N) Without using admixture, plasticiser (a) M15 prop. 1:2:4
(b) In super structure from plinth level up to 1st floor level. (ii) Column, pillar, post, struts………... (a) Without using admixture, plasticiser (a) M15 prop. 1:2:4
9.4.1. Providing barge board of size 200mm X 20mm with 1st class local Hollock/Bonsum timber including fitting and fixing with necessary wood screws etc. complete.
8.1.1. Providing corrugated galvd. Iron sheet roofing of TATA shaktee/SAIL including fitting and fixing necessary galvd. J or L hooks, bolts and nut 8mm dia with bitumen washer 25mm dia X 3mm thick and 1.6mm thick limpet washer complete excluding cost of roof truss, purlin etc. (roof trass and purlin etc. to be measured and paid separately). (a) 0.50mm thick
8.1.4. Providing galvd iron riding of TATA shaktee/SAIL including supplying and fixing necessary galvd screws/washers etc. complete as directed. (A) 0.50mm thick (ii) 230mm lpping.
6.2.2. 15mm thick cement plaster in single coat on rough side of single or half brick wall for interior plastrering………. 9a) on rough side (b) In cement mortar 1:4
13.2.3. (a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surface free from mortar dropping and other foreign matter and including preparing the surface even and sand papered smooth. surface even and sand papered smooth.
(b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required and of required shad on new wall surface (two coats) to give an even shade after thoroughly brooming the surface to removal all dirt and remains of loose powdered materials.
Steel truss with M.S. circular hollow section……………
Add extra for extra height of roofing and R.C.C. works..
ELECTRICAL WORK 1.1. Wiring for light /fan/call bell point with 2X1.5 Sq. mm PVC insulated single core unsheathed industrial (Multistand) cable FR conforming to IS-694 : 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 Volts (Finolex/RR cable or equivalent makes as approved by the Deptt. with flat 19mm ISI market casing 'n' capping) (AKG/Precision/Presto Plast/Polycab/MW or equivalent makes as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push (Anchor Penta/Gold medal/Kolor Kany. Kom/havells or euqvalent make as approved by the Deptt.) GI/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet kany. kom/Havells or equivalent make as approved by the Deptt.) etc. Complete as directed and specified by the Deptt. 1.1.1 Short point up to 3.00 meter length.
1.1.2 Medium point up to 6.00 metre length
1.1.3 Long point up to 10.00 metre length.
1.2 Wiring to 5 a pin 6 Amps plug point with 1.5 Sq. mm P.V.C. insulated single care unsheathed industrial (Multistrand) cable FR conforming to IS- 694 :1990 with flexible bright annealed electroytic copper conductor for voltage grade up to IS0 1100 volots (finolex/RR mm Kable or euquivalent make as approved by the deptt.) 2.2.2. Medium point up to 6.00 metre length
1.3. Wiring for 5/6 pin 16 Amp power plug point with 4 sq. mm PVC insulated S.C. unsheathed industrial multistrand) cable FR conforming to IS- 694 : 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 Volts (Finolex/R.R. cable or equivalent make as approved by the deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG/precision presto plast/polycab/MW or wquivalent make as approved by the deptt.) in surface system, including providing and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta/Gold medel/Kolor Kany. Kom/Havells or equivalent make as approved by the Deptt.) GI/MS switch board (I.S.I. marked) with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete. 1.3.2 Medium point up to 6.00 metre length
1.8. Wiring for drawing sub- main line with PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR cable or equivalent make as approved by the deptt.) in surface flat ISI market casing 'n' capping (AKG/precision/presto plast/polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.1. With 2X2.5 sq.mm + earth continuity with 1 X 1.5 sqmm In flat 19mm ISI market casing 'n' capping system.
1.8.2. With 2X4 sq.mm + earth continuity with 1 X 2.5 sq.mm Cable in flat 19mm ISI market casing 'n' capping system.
1.8.3. With 2X6 sq.mm + earth continuity with 1 X 4 sq.mm Cable in flat 25mm ISI market casing 'n' capping system.
1.11. Wiring for 5 pin 6 amp plug with 1.5 sq mm PVC insulated single core unsheathes industrial (Multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Cable or equivalent make as approved by the Deptt.) including providing & fixing 5 pin 6 amp socket outlet (Anchor penta/Gold medal/Kolor kany. Kom/Havells or equivalent make as approved by the Deptt.) and 6 amp flush type switch (Anchore penta/Gold madal/ kolor Kany. Kom/Havells or equivalent make as approved by the Deptt.) earthing the 3rd pin of the socket as required on the switch board in flat ISI market casing 'n' capping system, when fitted on same board of light and fan.
5.17. Supplying and fitting drawings of weather proof aluminium conductor cable of the following size as directed and specified by the department. 5.17.1. 2.5 sq.mm twin core
11.12. Supplying and fixing of polished brass bracket of 18 S.W.G, 25 cm long cast back plate and brass
11.16. Supplying and fixing of bulk head fitting suitable for CFL lamp complete with all accessories including connection as approved by the Deptt.
15.2 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc. fitted on wall with grounting nuts & bolts as required. complete with making necessary connection as approved, specified and directed by the deptt. 15.2.1. ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 15.2.1.3. 8 way SPN double door.
16.1 Supplying with fitting and fixing DP 10 KA 240/415V 50 Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the Deptt. 16.1.1. B Series (Schneider mg, legrand, Hager, Crabtree Xpro make) 16.1.1.1 6 to 32 A
16.3 Supplying with fitting and fixing of DP 10KA 240V/415V 50Hz MCB of the following capacity complete with makning necessary connection as approved specified and directed by the deptt. 16.3.1. B Series (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 16.3.1.3 63 A
22.7 Supply, Installation & testing of G.i. earth station with perforated 40mm dia and 4.5 meter Long heavy duty GI pipe with necessary 40mm dia. G.I. fittings such as Soket, Tee, elbow, nipple and 50mm X 40mm G.I. reducing socket for funnel including locking arrangement 300mm X 300mm X 6mm hinged cover C.I. earth plated complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt.
22.12. Extra for using salt 5 K and Charcoal 64 K in pipe Earth Stgation pit to provide low impedance group in location of high soil resistivity as and when required and specified by the Deptt.
22.16. Supplying & laying of 8 SWG Copper Earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the Deptt.
27.1. Supplying including fitting and fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connections as approved by the Deptt. As required complete and as directed by the Department. (Without regulator) 27.1.7. Premium model 1400mm sweep. (ORIENT PSPO make)/Usha make/CROMPTON make/Havells/ATC/ V GAURD make)
27.2 Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweep with making necessary connection as approved by the Deptt.) as required complete and as directed by the Deptt. 27.2.1. Domestic 27.2.1.2. Power Flow 225 mm sweep (ORIENT make)
27.6. Supplying fitting and fixing of ceiling fan regulator including connection etc. Complete as required. 27.6.2. Electronic Type
39.3 Supplying including installation, connection as approved by the deptt. testing and commissioning of CENTRIFUNGAL MONOBLOCK PUMP SET complete as directed and specified by the deptt. 39.3.2. 1 HP single phase centrifugal monoblock pump set (Crompton Greaves/Aquatic/CRI/ V Gourd/ Calma make) 2900 rpm with DOL Starter (Crompton Greaves/Control & Switch Gear/BCH/L & T/ Siemens make).
New 12: Supplying, installation, testing and commission of the following LED lamp as directed by the Department. 12.17. Philips LED Tubes Model Essential LED tube 1200mm 25W865 T8 I or equivalent as approved by the Deptt.
12.23. Philips LED bulbs non-dimmable 4 W or equivalent as approved by the Deptt.
Bakul Chandra Brahma
SAKALU BASUMATARY
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .