Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC 1723 GUPTA AND SONS SECTOR 39 B CHANDIGARH CHANDIGARH CHANDIGARH 160036 UDYAM CH 01 0042756 | CHANDIGARH | CHANDIGARH | 160036 | ₹1.1 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.1 Cr+₹2.6 L (2.35%)Rejected-AOC | ₹1.1 Cr+₹2.6 L (2.35%) | L2 | Rejected-AOC L2 |
| 3 | L3₹1.2 Cr+₹5.4 L (4.80%)Rejected-AOC GANDHI CHOWK LANSDOWNE DISTT PAURI GARHWAL PIN 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | ₹1.2 Cr+₹5.4 L (4.80%) | L3 | Rejected-AOC L3 |
| 4 | L4₹1.2 Cr+₹7 L (6.24%)Rejected-AOC 159 SHIV NAGAR MODIPURAM MEERUT 250 110 UP | MEERUT | UTTAR PRADESH | 250110 | ₹1.2 Cr+₹7 L (6.24%) | L4 | Rejected-AOC L4 |
| 5 | L5₹1.3 Cr+₹14.3 L (12.8%)Rejected-AOC SHOP NO 1 KARGI CHOWK HARIDWAR BY PASS DEHRADUN UTTARAKHAND | ₹1.3 Cr+₹14.3 L (12.8%) | L5 | Rejected-AOC L5 |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
3 Jun 2021, 6:00 pmClosed
CWE Dehradun
CWE Dehradun
ADDN ALTN CUM SPECIAL REPAIR OF OTM ACCN OF 4/4 GR AT DEHRADUN.
2021_MES_426064_3
9602/DDN/39/E8
Open Tender
Civil Works
Item Rate
270 days
Dehradun
As per tender documents
8 documents required · 8 mandatory
₹1,000
GE(P) Dehradun
₹2.2 L
Yes
16 Jul 2021
6 May 2021
5 Jun 2021
6 May 2021
3 Jun 2021
21 May 2021
Amount
Demolition of brickwork or stone/ boulder masonry including all quoins, arches, pillars, etc, built in cement mortar or cement lime mortar complete all as specified and directed.
Dismantling of Asbestos cement (corrugated ted, semi corrugated, etc.) sheets in roof coverings complete all as specified and directed.
Dismantling of CGI corrugated (or semi corrugated ) sheets in roofs covering including ridge and wind ties etc. complete all as specified and directed.
Dismantling of timber scantling 40 sqcm and over in section, in any position as in unframed or framed work complete all as specified and directed.
S&F second class hard-wood in of timber scantling, framed work in wrought complete all as specified and directed.
All as per srl item No 5 here in before but except timber scantling.
Taking down roof trusses (framed) clear span not exc 10 mtr complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Taking down chowkhats or frames area exc 1.50 Sqm but not exc 4.0 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkhats or frames area not exc 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
S&F in second class hard wood plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
M&L for mild steel work as in wind ties for roof including securing bolts, etc., and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
M&L for two coats of synthetic enamel paint on new steel Surfaces of any description, not otherwise, described, over 10cm width or girth over a coat of primer including preparation of surface complete all as specified and directed.
M&L for cutting holes in brick walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed.
M&L 2nd class Hard wood, 35mm thick factory made plain framed paneled shutter (Two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and slide as per IS: 1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F 35 mm thick factory made IInd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (with sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); supplied and fitted to chowkats complete all as specified and directed.
S&F galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
M&L for two coats of synthetic enamel paint on new wooden Surfaces of any description, not otherwise, described, over 10cm width or girth over a coat of primer including preparation of surface complete all as specified and directed.
M&L 100mm long Butt hinges, medium weight, cold rolled mild steel and fexed complete all as specified and directed.
S&F for 125 mm long Aluminium handles, cast type, anodized complete all as specified and directed.
S&F for 200 mm long Aluminium tower bolt, anodised complete all as specified and directed.
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Complete all as specified and directed.
S&F 300mm size, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with out glazing bars, dovetailed or welded complete all as specified and directed.
S&F mild steel chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain let in and fixed independently in wooden frames L or T section support for shelves etc., and similar articles conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
S&F 4 mm thick Sheet glass, ordinary quality and glazing with oil putty in square in n.exc 0.5 sq.m in each pane complete all as specified and directed.
M&L for Brickwork with subclass 'B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
M&L for Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 20 mm thick bedding layer of CM 1:4 over with and including cement slurry 3 kg/sqm complete all as specified and directed.
M&L for 8 to 10 mm thick coloured ceramic tiles of size 600x600 mm laid over and including 10 mm thick bedding layer of CM 1:3 as in skirting/dado complete all as specified and directed.
S&F Anodised aluminium snap grid frame work for false ceiling, Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified with 6mm Non asbestos fibre cement building fixed or laid/inserted to timber/GI/Aluminium framework with screw, flat or sloping complete all as specified and directed.
M&L for complete removal of existing treatment from wall surface complete all as specified and directed.
M&L for rendering 12mm thick on fair faces of brick work or concrete surfaces in CM 1:6 complete all complete all as specified and directed.
M&L for two coats of oil bound distemper over a coat of primer including preparation of surface complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in (in two layer ist layer 10 mm thick in CM (1:6) and IInd layer mixed with water proofing compound 5 mm thick in CM 1:4 complete all as specified and directed for external services complete all as specified and directed. Note : WPC shall be measured and paid separately
Supply Only integral water proofing compound.
M&L two coats of cement based paint over a coats of primer including preparation of surface on newly plastered surface of wall complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for PCC 1:3:6 type C 1 (20 mm graded aggregate ) , plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified and directed.
M&L for forming construction joint 30mm deep x 10mm wide filled with polysulphide sealing compound over polyethylene back up rod complete all as specified and directed.
M&L for 50 mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in floor surface finished even and smooth without using extra cement including roughning of old surface of concrete complete all as specified and directed.
M&L Preparing surface of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with creosote complete all as specified and directed.
M&L for mild steel work as in hold fasts; conforming to Fe410-0 or Fe 310-0 complete all as specified and directed.
M&L two coats of black Japan paint on surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and directed.
S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and complete all as specified and directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets
Fixing only Celing Board complete all as specified and directed.
M&L for mild steel work as in roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
M&L for mild steel work as in compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc complete all as specified and directed.
M&L for hard core of gauge n.exc 63mm broken stone or boulder deposited spread and levelles in layers n.exc 15 cm thick watered and rammed to a true surface etc complete all as specified and directed
S&F Steel ventilators with centre hung shutter including hinges, steel peg stay, complete all as specified and directed.
M&L for applying a coat of black japan paint on surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and directed.
Surface dressing n exc 15 cm deep getting out hard dense soil complete all as specified and directed.
Excavating in trenches, n.exc 1.5m wide & n.exc 1.5m in depth; for foundation, etc or for shafts, wells, cesspits, laying of pipe/cable manholes, pier holes, etc. nexc10 sq m on plan & n exc 1.5 m in depth & getting out in any type of soil complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (40mm graded aggregate) Cement concrete in foundation, fillings & mass concrete complete all as specified and directed.
M&L for RCC 1:2:4 type B1 (20mm graded aggregate) use in Foundation, including rafts, footing, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles & mass concrete complete all as specified and directed.
M&L RCC 1:2:4 type B1 (20mm graded aggregate) use in beams, cantilevelers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L RCC 1:2:4 type B1 (20mm graded aggregate) use in Chajjas complete all as specified and directed.
Use and waste form work (rough finished surfaces of concrete) to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
Use and waste form work (rough finished surfaces of concrete) to sides & soffits of floor or roof beams haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors & beams, etc complete all as specified and directed.
Use and waste form work (rough finished surfaces of concrete) to chullah hoods, chajjas, troughs & similar items including edges complete all as specified and directed.
M&L for mild steel bars 10mm dia & over, cut to length bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and directed.
All as per srl item No 63 above but 5mm dia & over upto & including 10cm dia in stirrups, spacers & binders.
M&L for cutting out bricks, forming toothing for, & bonding for brick work built in new brick work in CM (1:6) including value of new materials entering old walls & jointing & pointing CM (1:3) complete all as specified and directed.
M&L for cutting openings through walls for door, windows & other openings or enlarging existing openings, etc. built in CM 1:6 or cutting out defective masonry for underpinning including providing, fixing & removing, shoring, cleaning & stacking bricks & removing surplus to store & rubbish out of the premises complete all as specified and directed.
M&L cement concrete (1:3:6) , type C-2 concrete bed to drain pipes including packing and haunching against the sides of pipes after they are laid and tested of 110 mm bore complete all as specified and directed
Excavation over areas, exc 1.5 m deep and getting out in hard dense soil complete all as specified and directed.
M&L PCC 1:5:10 Type E2 (40 mm graded aggregate) for foundations, filling and mass concrete complete all as specified and directed.
M&L 40 mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) for floor, finishing th cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for glazed ceramic tiles (200x200mm) x 7mm thick, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 20 mm thick bedding layer of CM 1:4 over including cement slurry 3 kg/sqm complete all as specified and directed.
M&L for gGlazed ceramic tiles in vertical surface 350x250mmx7mm/450X350X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10 mm thick bedding layer of CM 1:3 as in skirting/dado complete all as specified and directed.
M&L for hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks, straight or curved on plan exc 6m mean radius, in half brick work thick wall built in CM 1:4 complete all as specified and directed.
Use and waste form work (rough finished surfaces of concrete) to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed..
M&L RCC 1:2:4 type B 1 (20 mm graded aggregate) usr in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L Precast cement concrete in 1:2:4, type B-1, 20mm thick graded stone aggregate in manhole cover slab set in CM 1:4. complete all as specified and directed.
M&L for mild steel bars 6 to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to TMT bars complete all as specified and directed.
M&L for cement concrete 1:4:8 type D2 (40 mm graded aggregate) using in surface channels and drains complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 55 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc complete all as specified and directed.
M&L for PVC (SWR) pipes 110 mm bore size single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
M&L Cement concrete 1:3:6, type C2 concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested of 150mm bore complete all as specified and directed.
M&L for PCC 1:2:4 type B0 using 12.5 mm aggregate in coping complete all as specified and directed.
S&F 110 mm PVC (SWR) bends any radius complete all as specified and directed.
S&F PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed.
S&F 32mm dia Waste coupling of PTMT (half or rull threaded) complete all as specified and directed.
S&F 32 mm dia Low density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls. Ceilings or in floors etc complete all as specified and directed..
S&F grating doom 125 mm dia with waste hole of PTMT, Minimum weight 40 gms complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed..
M&L for 5 mm thick rendering on fair faces of brick work or concrete surfaces of CM 1:3 in ceiling complete all as specified and directed.
M&L three coats of white wash on fair faces of brick work or concrete surfaces in ceiling including preparing of surface complete all as specified and directed.
S&F 20mm dia steel tubes, `medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F 15mm dia steel tubes, `medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F 20mm bore Stop valves, cast copper alloy screwed pressure, with crutch of butterfly handle, screwed both ends for iron pipe for unions and fixed complete all as specified and directed.
S&F 15 mm bore Bib taps, cast copper ally with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, fancy type with chromium plated complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing with water etc complete all as specified and directed.
M&L for applying one coats of white wash on old surface complete all as specified and directed.
M&L a coat of cement based paint on old surfaces of wall incl prepration on plastered surface
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 20 mm thick bedding layer of CM 1:4 over slab/sub base/grade with hacking incl cement slurry 3 kg/sqm complete all as specified and directed.
M&L a coats of white wash including preparation of old plastered surface of ceiling complete all as specified and directed.
S&F low density polythene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floorings, etc of 32mm complete all as specified and directed.
S&F in repairs Grating doom 100 mm dia of PTMT. Minimum weight 25 gms complete all as specified and directed.
S&F in repair 75 mm out side diameter PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
S&F in repair 15mm bore Stop valves, cast copper alloy screwed pressure, with crutch of butterfly handle, screwed both ends for iron pipe for unions complete all as specified and directed.
Taking up or down steel tubing 15/20 mm bore and connections complete all as specified and directed.
S&F Fiber glass reinforced plastic (FRP) door shutters of 30mm thick are to be made with unsaturated polyester resin moulded to 3mm FRP laminate for forming hollow rails and stiles, suitably treated and seasoned rubber wood are to be fitted inside at required places for fixing of fitting cast monolithically with 5mm thick FRP laminate for panels with gel coat finish and with average weight of 8 kg/Sqm complete all as specified and directed.
S&F Fiber glass reinforced plastic (FRP) door frame of 100mm X 60mm thick are to be laminated with inner core of treated and seasoned rubber wood and outer core of average 2mm thick FRP with gel coat finish weighing an average of 4 Kgs/RM complete all as specified and directed..
S&F 150mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S&F 100mm stainless steel butt hinges medium weight complete all as specified and directed..
S&F Aluminium anodised barrel tower bolts of extruded sections and fixed 150mm size.
S&F Aluminium handles, cast type anodised of 150mm size complete all as specified and directed..
S&F in repair Brass chromium plated shower rose 125mm size. with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
M&L rendering 10mm thick 1:3 CM on brick work or concrete surface finished even and smooth without using extra cement with using WPC complete all as specified and directed. (Note WPC shall be measured and separately
M&L for applying APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) laid on primed surface by forced application complete all as specified and directed.
M&L for applying Bitumen primer on plastered surfaces for use in waterproofing and damp-proofing treatments as per manufacturer instruction complete all as specified and directed.
M&L for two coats of aluminium paint Surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and directed.
M&L for Cutting in to existing man holes for connecting new drains, making good to pipes and rendering, cutting out existing benching & forming branch channel in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required for 150 mm pipe complete all as specified and directed.
S&F in repair Vitreous china wash down water closet Pedestal pattern including, Seat and cover all fittings complete all as specified and directed.
S&F in repair Vitreous china water closet squatting pan of pattern 'long pan' size 580 mm white with 'P' or 'S' trap complete including concrete bedding complete all as specified and directed.
S&F in repair PVC valve less symphonic action type flushing cistern low level 10 ltr capacity white with inlet ball valve float and handle including flush pipe complete all as specified and directed.
S&F in repair concussive push button taps cast copper alloy screwed for iron pipes and fixed to 15mm bore complete all as specified and directed.
S&F 15 mm bore PVC connection with brass nuts of 450 long complete all as specified and directed.
S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed.
M&L for brushing neat cement slurry with 3.0 kg of cement per sqm complete all as specified and directed.
M&L for cement concrete type B-1, 1:2:4 (20 mm graded aggregate) 100 mm thick as in floors and paving complete all as specified and directed..
M&L for applying two coats of plastic emulsion paint over one coat of primer including preparation of surface on concrete surfaces (not exc 10 cm width or grith) complete all as specified and directed.
M&L 100 mm thick Cement concrete type D2, 1:4:8 (40mm graded aggregate) for sub base of floor complete all as specified and directed.
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in near cement slurry in floors including Screed bed or bedding layer or mortar 15mm layer of mortar 15mm thick for laying floor finishes complete all as specified and directed.
M&L for PVC (SWR) pipes single 75 mm bore socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
Removing excavated soil to a distance exceeding 100 metres but not exceeding 150 metres and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Demolition and breaking up drain pipe (Salt glazed ware, AC or re-inforced concrete) set in cement mortar of 150mm bore complete all as specified and directed.
S&F SGSW drain pipes 150 mm dia laid in trenches and jointed complete all as specified and directed.
M&L for rendering 10mm thick on fair faces of brick work / concrete surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
Demolition of re-inforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed..
M&L Walling of random rubble, brought upto coursed ,well bonded, bedded & solidly hearted, built in CM 1:6 complete all as specified and directed
M&L for raised pointing to random or polygonal rubble, uncoursed on brought up to courses complete all as specified and directed.
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed.
Excavating over areas, n exc 1.5 m deep and getting out in hard/dense soil complete all as specified and directed.
Supply and laying replacement 50mm bore of pipe steel pipe galvanized, “Medium class”, laid in trenches including testing complete with fittings such as flanges ,unions, reducers, sockets bends ,elbows, tee, chech nuts, caps, plug etc ISI marked for flowing for following sizes complete all as specified and directed.
All as per srl item No. 142 above but 25 mm bore.
Supply and fix 50mm nominal bore gun metal gate valve heavy duty duly ISI marked, with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
All as per srl item No. 144 above but 25 mm bore.
M&L for Removing of excavated soil to a distance n. exc. 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M & L for construction of brick masonary valve pit of size 600x600x600 mm (internal dimensions) with brick work of sub class B old size bricks built in cement mortar 1:4 and 10 mm thick rendering on internal and exposed external surfaces and including 40x40x6mm mild steel angle frame 3.15 mm thick mild steel sheet cover with lifting handle and locking arrangement including painting steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer complete all as specified, shown on drawing and as directed.
M&L in replacement in existing point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS-H grade in and including medium duty concealed PVC conduit 20 mm dia or higher and conduit fittings and all accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.2mm thick, duly painted for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, including continuous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS-H grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of the following. (Note: Colour code shall be maintained as per IE rule) Note : cost of cutting chases on walls excluding ceiling portion n.exc 10cm width and making good surfaces with cement mortar (1:4) as directed , deemed included in quoted rate.
(a) One light point /bell buzzer point controlled by one-one way switch.
(b) One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
(c) One three pin 5 Amp socket on same board with other switches.
(d) One three pin 5 Amp socket on independent board
All as per item No 148 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity conductor of size 2.5 Sq mm.
M&L for new point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS-H grade in and including medium duty concealed PVC conduit 20 mm dia or higher and conduit fittings and all accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.2mm thick, duly painted for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, including continuous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS-H grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of the following. (Note:- Colour code shall be maintained as per IE rule) Note : cost of cutting chases on walls excluding ceiling portion n.exc 10cm width and making good surfaces with cement mortar (1:4) as directed , deemed included in quoted rate.
(a) One light point /bell buzzer point controlled by one-one way switch.
(b) One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
(c) One three pin 5 Amp socket on same board with other switches.
(d) One three pin 5 Amp socket on independent board
All as per item No 150 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity conductor of size 2.5 Sq mm complete all as specified and directed.
S&F switch piano flush, button type 5 Amp SP 250 V AC complete all as specified & directed.
S&F switch piano flush button type 15 Amps SP 250 V AC complete all as specified & directed.
S&F socket outlet multipurpose 3 Pin 5 Amp 250 V AC complete all as specified & directed.
S&F socket outlet two in one three pin 5 Amp and 15 Amp 2 module 120 W flush type complete all as specified and directed.
S&F stepped type electronic fan regulator flush type two module 400 Watt on the existing phenolic laminated sheet etc as required complete all as specified and directed.
S&F ceiling rose, 3 terminal/PVC/polycarbonate, isolated body 250 V AC complete all as specified and directed..
S&F lamp holder PVC/polycarbonate type with back plate suitable for batten fittings.250 V AC.
M&L sub main wiring with 2 Single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multi stranded of size 6 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed, conduit heavy duty accessories and fittings wit chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multi stranded of size 6.0 Sq. mm. as earth wire up to common earth and connected to earth dolly complete all as specified & directed including taking down old sub main wiring complete all as specified and directed.
M&L sub main wiring with 2 Single core PVC insulated unsheathed FRLS -Hcable 1100 Volts grade heavy duty copper conductor multi stranded of size 6 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed, conduit heavy duty accessories and fittings wit chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multi stranded of size 6.0 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed.
S&F in replacement sheet metal enclosures 240 volt with 200 amps rated copper bus bar for double door 8 way IP-43DB's lk-09suitable for one MCB SPN as incoming and 6 MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engr-in-charge . (Note ;- MCBs shall be measured and paid separately).
S&F NEW sheet metal enclosures 240 volt with 200 amps rated copper bus bar for double door 8 way IP-43DB's lk-09suitable for one MCB SPN as incoming and 6 MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engr-in-charge. (Note:-MCBs shall be measured and paid separately).
Supply & fixing and Testing TP & N Vertical load line (VTPN) 4 way 415 Volts 50 Hz indoor type double door sheet metal enclosure IP-43 DB's IK-09 flush mounted with 250 Amp Copper bus bar for each phase with two neutral bar & two earthbar and cable ties for cable management including Provision of MCCB 63 Amps,ICs=100%ICu, 16KA four pole as in comer including connecting terminal strip complete and SP MCBs as out going etc complete pre wired with suitable size copper conductor. The DB's shall hold type test certificate (CPRI) as per IEC 61439-3 complete all as specified and directed by Eng-in-charge including taking out old unserviceable DB and removing from site and making good of disturbed surface .(Note :-(a) MCB/ MCCB shall be measured and paid separately) (b) item no 161 to 163 make of DB shall be same make of MCCB/MCBs to be incorporated
S&F MCB double pole 240 Volt 10 KA 40 Amp 'B' series conforming to ISI marked complete all as specified & directed.
S&F MCB single pole and 240 volt 10 KA 5-32 Amp 'B' series conforming to ISI marked all as specified and directed .
S&F MCCB 415 Volt 16 KA 3 pole 63 Amp magnetic trip release & setting as incoming with fixing arrangement complete all as specified and directed.
S&F in replacement wall mounted LED tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed including taking down old tube light fitting . Make: (i) Philips cat part No TMC1001xT LED 13-20w WH(Tube Batten) MAS LED 1200mm 18W-865-T-81 (ii) Wipro Cat part No WI0921208 (Tube Batten) LL13-181-650 (Tube)/ (iii) Havells Cat Part No REGAL BATTEN 8UPTO 1X20W SSBS WH( Batten)PHOTONULTRAE2.01213T118WLED 865 SPC
S&F wall mounted LED tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed including taking down old tube light fitting .Make: (i) Philips cat part No TMC1001xT LED 13-20w WH(Tube Batten) MAS LED 1200mm 18W-865-T-81 (ii) Wipro Cat part No WI0921208 (Tube Batten) LL13-181-650 (Tube)/ (iii) Havells Cat Part No REGAL BATTEN 8UPTO 1X20W SSBS WH( Batten)PHOTONULTRAE2.01213T118WLED 865 SPC
S&F LED light fitting 1x10 w bulk head fitting complete with accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size Make: : (i) PHILLIPS CAT PART No :- WT140WLED7SCWPSUS1PC (ii) HAVELLS CAT PART No :- HEXAFT 10W LED 857SSYMBOPC .(iii) WIPRO CAT Part No :- LW07-141-XXX- 57XX
S & F high efficiency LED bulbs 1 X 12 watt that can be used as a ready replacement for existing GLS ad CFL direct fit in holder complete all as specified and directed. Make (i) Phillips stellar bright high wattage 12 W LED bulb.(ii) HAVELLS CAT PART No LHEAABP71L1W012 (iii) C&S CAT PART No CORONA-RND/18W/W
Taking down & Re fix ceiling fan of any type of sweep single phase 230 volts with down rod , canopy, blades etc including connecting with twisted three cord flexible copper conductor cable (23/.0076 ) from ceiling rose to connector of fan after greasing/oiling, painting etc and writing MES No on fan complete all as specified and directed.
Supply & fix ceiling Fan 1200 mm any type and sweep single phase 230 volts double ball bearing with down rod , canopy, blades etc BEE 5 star rated including connecting with twisted three cord flexible copper conductor cable (23/.0076 ) from ceiling rose to connector of fan and writing MES NO on fan complete all as specified and directed .
S&F Geyser vertical mount type 25 Ltrs capacity five star rated , shockproof and rust proof metal body compact size including two Nos PVC connection heavy duty and connecting with all fixing arrangement of nuts & bolts and fixing on wall complete all as specified & directed .
S&F air ventilation fan metallic body 300mm, 900 RPM with louvers, single phase, 230V AC including necessary, M&L for making hole fixing arrangement on wall with frame hold fast, bolt, washer etc including connection with twisted white three core flexible copper multi stranded conductor cable from ceiling rose to connector all a directed by Engineer-in-charge.
M&L for earthing complete with using galvanized mild steel earth plate (electrode) 600 mm x 600 mmx 6 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to be packed thickness of 15 cm all round the plate using 4 mm dia GI earth lead wire as earth lead moulded and riveted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead protected in and including 15 mm dia GI ‘medium grade’ pipe from upper end of earth plate up to equipment with & including 20 mm dia bore GI pipe ‘medium grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone aggregate) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as per electrical plate No.3 of SSR Part-II 2010 and testing on completion all as specified and directed. Note-(i) If the desired earth resistance is not found within permissible limit, item shall be re-done by Contractor at no extra cost. (ii) Cost of GI wire 4 Sqmm and 15mm dia GI pipe medium grade upto 7.5m is deemed to be included in the rate quoted for this item.
Supply and Fixing in replacement Integral LED Street Light Luminaries comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 45 watt with efficiency 100 lumen/watt at system level, CCT>5700K, with average life class 50,000 burning hours including GI bracket made out of 25 mm GI pipe medium grade and MS clamps for fixing of light fitting complete and connected with twin core PVC insulated copper flexible cable with existing point all as specified and directed. Make (i) Philips Cat Part No :- BRP056 LED53 CW SLF PSU S1 (45W 5300 LUMENS STREET LIGHT) (ii) HAVELLS CAT PART No :- ENDURAPEARLNEOS145WLED757PASYTOPC (iii) C&S CAT PART No :- LTESS1 45WLED/LS
Supplying, laying in replacement, jointing and testing LT underground cable of size 25sqmm4 core heavy duty, 1100 Volts, PVC insulated and sheathed, armoured with multi-stranded aluminium conductor cable conforming to latest IS , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly protected in galvanised steel pipe of suitable sizes all bare conductor of cable duly insulated 1.1 KV grade heat shrinkable sleeve including cable gland and lugging etc at both ends all complete all as specified and directed. Note : Excavation, earth work, cable sand cushioning & cable protection shall be measured separately under relevant items of this schedule.
All as per srl item No 177 above but of size 16sqmm 4 core.
All as per srl item No 177 above but of size 10sqmm 2 core
Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable ) and gently punned down to 18cm thickness all complete all as specified and directed. Note :- Only punned down sand thickness 18CM shall be measured and paid
Supplying and laying old size bricks, laid flat ie length of brick shall be laid across the cable, common burnt clay building bricks sub class `B' designation 75 complete all as specified and directed and testing on completion complete all as specified and directed.
M/S SETHI BROTHERS
PIONEER REFRIGERATION AND ELECTRICALS
Arun Construction Co.
OM TRADERS
M/s Anil Kumar
RAMAPATI ENGINEERING SERVICES
VERDHMAN ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .