Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical KUNNATH CHALI THALAMUNDA KOODALI | KOODALI | KANNUR | KERALA | - | Rejected-Technical L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical L3 |
Tender Value
Refer Docs
EMD Value
₹31,355
Closing Date
10 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assisstant Executive Engineer
Office of the Assistant Executive Engineer PWD Electrical Subdivision Thalassery
GENERAL-Budget 2023-2024 Town Beautification work for Pachappoyika town in Dharmadam LAC -Providing Decorative Lighting for Pachapoyka Town -General Electrical Work
2023_PWD_619062_1
PWD/BLDG/TR/16450/2023_6_1_1/1
Open Tender
Electrical Works
Item Rate
180 days
Thalassery
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹31,355
28 Nov 2024
4 Nov 2023
13 Nov 2023
4 Nov 2023
10 Nov 2023
4 Nov 2023
Amount
Footpath Lighting
OD121537/2023-2024:Supply installation testing commissioning of Decorative Pole 3 meter height above the ground level made out of GI, tubular pole ‘T’ washed and premièred (ASTM A123) having two section section, bottom section of minimum 1000mm with base dia of 114mm and upper section of minimum 2000mm with dia of 76mm. The pole shaft shall be as per IS 1161.The pole shall have castiron embellishments. The pole shall have base plate of dimension 200x200x12mm. The pole shall be with inbuilt junction looping box at bottom section with 32 A heavy duty 4 way connector for loop in & loop out and with MS base plate.The pole shall be suitable for wind loadings as per IS 875 part 3 1987. Design comply EN40 standard and basic wind speed 169kmph.Pole should hot dip galvanized to 65 microns to IS 2629:985/ IS 4759:1996 / IS 2633:1986. The Pole should be given with two coats of epoxy primer and above that it should be given with polyurethane UV resistant coating (painted with avg. DFT of 70μm). The complete system should be hot dipped Galvanised. ( Kesslec 3M Decorative RILA Pole GI with base plate/Crompton Trossa/bajaj jordhan
OD121538/2023-2024:SITC of LED Decorative Classic luminaire of system wattage 40W, BIS certified with a body and frame of high pressure die cast aluminium, a frosted PMMA protector (IK06) fixed on to the optical unit, separate optical and control gear compartment accessed by opening four screws at the top of the luminaire, a vent pressure equalization unit and pre-cabled as required. The luminaire shall have ingress protection of IP66. Highly efficient temperature resistant lenses for light distribution with several optical options providing excellent photometry to optimally cater to different applications. Overall system efficiency of 110lm/W at correlated colour temperature (CCT) 3000K, colour rendering index (CRI) >70 and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor ≥ 0.95, with BIS certified potted driver having internal surge protection of 4 kV and an additional surge protection device (SPD) of 10 kV. ( KESSLEC RILA 40W WW LED/equivalent)
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
OD157980/2023-2024:Providing 15mm thick cement plaster of mix 1:4 (1 cement: 4 fine sand) at all levels
OD121534/2023-2024:Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete .Thermo-Mechanically Treated bars of grade Fe-500D or more.
90.12.5.3:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm
90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm
9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
90.16.2.4:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.40 mm dia G.I. pipe ( medium class)
OD157968/2023-2024:Supply laying and clamping of the following sizes of B class GI pipe using stain less steel clamps spacing not exceeding 40cms making good the damages as required 32mm dia GI pipe (medium class)
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
90.16.1.10:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.25 mm GI conductor (10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
OD121540/2023-2024:Supply and fixing Time switch 240V AC DIN/BASE mounting(L&T J648B1-Analog version)/Hager in the existing enclosure and giving connection as required-
OD121541/2023-2024:Supply and fixing 25A AC3, MNX 25, 2 Pole power contactor (L&T) conforming to IS/IEC 60947-4-1 & IEC60947-4-1 in the existing enclosure and giving connection as required-
OD121542/2023-2024:Supply and fixing 32A HRC fuse base with HRC fuse link-
OD121543/2023-2024:Supply and fixing of Neutral link 32 A, 2 Way neutral links mounted on DMC/SMC base-
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
90.6.4.1:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 1 Run
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD121544/2023-2024:Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required. 25 mm X 5 mm G.I. strip
OD121545/2023-2024:Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. 2 x 25 x 5 mm GI strip
90.16.1.11:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.06 mm GI conductor (8 SWG)
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
OD121546/2023-2024:Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required. 25x6 mm brass nut and bolt
OD157390/2023-2024:Supply and fixing 32mm dia 6Kgff/cm2 PVC Pipe including fixing the pipe with clamp/clips at 60cm spacing. etc. as required (for service pipe)
OD157403/2023-2024:Supply and installation of bollard light of 1000mm or nearest height on existing concrete foundation with foundation bolts etc. as required (K lite 6955 trio bollard/6976 cuba bollard/ equivalent)
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
OD157965/2023-2024:Supply Conveyance, installation, testing and commissioning of 12W, round surface mounting down light fittings of all types directly on ceiling including giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required.
OD157966/2023-2024:Supply Conveyance, installation, testing and commissioning of 4W integrated LED wall washer light of 250lm ,3000K with IP 65 protection with Aluminium housing, duly wired up for use on 230 V AC supply. (Philips Double Head Wall Washer Gamma LED Wall Light/equivalent)
OD121535/2023-2024:Supply Conveyance, installation, testing and commissioning of 20W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD121539/2023-2024:Supply, conveyance & installation of Hensel make IP 66 / IP 67 weather proof 180x 130 x 77 mm cable junction Box ( KF 1006 B) with Terminal Set 2.5-6 sq.mm Copper
OD121547/2023-2024:Hire and Labour charges for Conreate core cutting
Madhusuthanan K P
sajithvc
Bidder Name
PRADEEP KUMAR.V.K
sajithvc
Madhusuthanan K P
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_929539.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .