Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.4 LAccepted-AOC | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹36.2 L+₹77,689.13 (2.20%)Rejected-Finance | L2 | Rejected-Finance Other than L1 after deducting sch of credit Rs 18121 | |
| 3 | L3₹36.5 L+₹1.1 L (3.05%)Rejected-Finance 5 A LANE 1 GREATER KAILASH JAMMU J K 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | L3 | Rejected-Finance Other than L1 after deducting sch of credit Rs 18121 | |
| 4 | L4₹36.8 L+₹1.4 L (3.96%)Rejected-Finance 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L4 | Rejected-Finance Other than L1 after deducting sch of credit Rs 18121 | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Others-Withdrawal from bidder as per application received |
Tender Value
₹33.7 L
EMD Value
₹67,400
Closing Date
29 Nov 2021, 6:00 pmClosed
GE North Akhnoor
GE North Akhnoor C/o 56 APO
SPECIAL REPAIR TO MULE LINE AT BLDG NO P63 AND CERTAIN REVENUE AND MINOR WORKS AT SUNDERBANI MIL STATION UNDER GE NORTH AKHNOOR
2021_MES_478596_2
GE(N)/AKH-49/2021-22
Open Tender
Civil Works
Item Rate
180 days
Sunderbani
Class D cat a i b i
8 documents required · 8 mandatory
₹500
Yes
GE North Akhnoor
₹67,400
Yes
11 Feb 2022
5 Nov 2021
1 Dec 2021
5 Nov 2021
29 Nov 2021
8 Nov 2021
Amount
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Demolition of stone/brick masonary built in cement/cement lime mortar including all quoins arches etc but exlcuding ashlar masonry complete all as specified and directed.
Brickwork with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 complete all as specified and as directed by Engineer -in-Charge
Ditto all as per Srl item No 4 here-in-above but except bricks.
Roughening surface of old concrete floor by picking sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
M&L for brushing neat cement slurry with 3.0kg of cement per sq. metre
M&L for 40mm thick PCC 1:2:4 Type B-1 (using 20mm graded stone aggregate) as in roof padding of roof slab in slope finished surface even and smooth without using extra cement complete all as specified and directed.
Water proofing treatment to RCC roof slab including parapet as under :- (a) Ist Course : Apply a coat of bituminous primer conforming to IS-3384@ 0.40 Kg /Sqm on prepared surface of plaster and after drying of primer, apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm on plastered surfaces. (b) 2nd Course : APP (Atactic Polypropylene) modified polymeric membrane, 5 layered, 3 mm thick weight not less than 4.0 Kg/Sqm with 160 Grams/Sqm non woven polyester made at centre core reinforced laid with 75 mm side overlap and 150 mm end overlap, membrane has to be laid with LPG torch and overlap sealed and finished neat, all joints and changes in direction should be covered with cement mortar 1:3 mixed with SBR latex @200ml/bag of cement and curved before laying of membarance. (c) 3rd Course : Apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm over membrance and dusted with dry sand @ 0.50 to 1 Kg/sqm.
Note : (i) Roof treatment work shall be carried out through approved manufacturers only. (ii) If Non-accesible roof : After providing (a) to (c) provide aluminium paint as per manufacturer instructions. (iii) Covered fillet in PCC 1:2:4 type B0 using 12.5 mm graded crushed stone aggregate of required radius shall be provided at the junction of roof and vertical surface such as parapet wall/mumty around opening and treatment mentioned above shall be applied followed by a cement plaster 20mm thick in cement mortar(1:6).
M&L for machine cut kota stone slab flooring 20-25mm thick as in flooring jointed with grey cement slurry mixed with pigment to match the shade or the slab including rubbing and polishing complete including 20mm thick screed bed in CM 1:4 for laying floor finishes complete all as specified and as directed by Engineer-in-Charge.
M&L for 25 mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) for laying floor finish complete all as specified and directed.
Machine cut kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete,over and including 10 mm thick rendering in cement and sand mortar 1:4. all as specified.
M&L for Glazed ceramic tiles, coloured 450x350x7mm thick on vertical surface such as skirting/dado over & jointed in neat cement slurry & pointed in white or coloured cement to match the shade of tiles including 15 mm thick in CM 1:4 bedding layer to receive tiles complete all as specified and as directed by Engineer-in-Charge.
Rendering 15 mm thick in cement and sand mortar 1:4 on fair faces of brick work or cement concrete surfaces including finishing the surface fair and even (without using extra cement) complete all as specified and as directed by Engineer-in-Charge.
Rendering 15 mm thick in cement and sand mortar 1:6 on other than fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth (without using extra cement) complete all as specified and as directed by Engineer-in-Charge.
Rendering 10 mm thick in cement and sand mortar 1:3 on cement concrete surfaces of ceiling including finishing the surface even and smooth (without using extra cement) complete all as specified and as directed by Engineer-in-Charge.
M&L for Preparation of new treated surfaces of walls and applying two coats of distemper oil emulsion over one coat of chalk whitening complete all as specified and directed.
M&L for Preparation of new treated surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L for preparation of old plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for Preparation of old treated surfaces of walls including washing rubbing down and stopping distempered and applying one coat of distemper oil emulsion complete all as specified and directed.
M&L for Preparation of old treated surfaces of walls and applying one coat of cement base paint complete all as specified and directed.
S&F brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long including brackets complete all as specified and directed by Engineer-in-Charge.
S&F in repair 32 mm dia PVC waste pipe 90 cm long fexible type for Wash basin complete all as specified and as directed.
Taking up or down 15mm steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by Engineer-in-Charge.
Taking up or down 20mm steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by Engineer-in-Charge.
Fixing only tubes any grade 15mm bore to walls and ceiling or in floors etc including provision of new fittings as required (Serviceable galvanised tubes retrieved from respective items shall be laid under these items) all as specified and directed by Engineer - in - Charge .
All as per Srl Item No. 29 here-in-above but for 20mm bore all as specified
S&F 15 mm bore mild steel galvanized steel tubing with screwed socket joints, medium grade, together with all fittings (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors including , screwing and waste and for forged bends on piping as required , cutting through walls, floors and their making good to match with the existing specifications complete all as specified and as directed by Engineer-in-Charge.
All as per Srl Item 31 here-in-above but for 20mm bore all as specified
Bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, for bore dia of pipe 15mm, supplied and fixed in repairs complete all as specified
Dismantling water tanks exc 500 litres and n exc 1000 litres removing to store complete all as specified
Rotational moulded polyethylene water storage tanks of 1000 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc complete all as specified and directed by Engineer-in-Charge.
Rotational moulded polyethylene water storage tanks of 500 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair ball valve high pressure of PTMT with epoxy coated Aluminum rod & high density plastic ball screwed for iron pipe or brass ferrule 20mm bore (minimum weight 210 gms) , complete all as specified and directed by Engineer-in-Charge.
M&L Cement concrete in foundations, filling and mass-concrete Type D2, 1:4:8 (using 40 mm graded stone aggregate) complete all as specified & directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size conforming IS 15658-2006 of 80mm thickness M-35 grade with grey cement and pigment (glazed) over a layer and including 25mm thick sand cushioning complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size conforming IS 15658-2006 of 60mm thickness M-35 grade with grey cement and no pigment over a layer including 25mm thick sand cushioning complete all as specified and directed.
M&L for Plain cement concrete type B-1 1:2:4 (using 20 mm graded stone aggregates) as in benching and copings including weathering, slightly rounded or chamfered angles and throating and necessary form works, all as specified and directed.
M&L for 50 mm thick 75 cm wide PCC type C-1 1:3:6 (using 20mm graded stone aggregate) as in plinth protection laid in bays complete including 75mm thick consolidated hard core of broken stone over rammed earth finishing the surface of concrete topping even & fair, without using extra cement filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight) complete all as specified and as directed by Engineer-in-Charge. Note :- The rate quoted shall be deemed to include for use and waste of form work / screed strips and to divide the area in panels including hardcore.
M&L for Reinforced cement concrete (Nominal mix), type B1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer -in-Charge.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for fair finished surfaces.
TMT reinforcement bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed by Engineer -in-Charge.
M&L for PCC 1:2:4, B-1 (20mm graded stone aggregate) as in surface channels and drains etc complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.
Rough excavation not exceeding 1.5 m deep and getting out in any type of (soft/hard) soil complete all as directed by Engineer-in-Charge.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
M&L for Brickwork with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:4 complete all as specified and as directed by Engineer -in-Charge
S&F 450mm dia reinforced concrete pipes, class NP3, laid and jointed complete with collars all as specified and as directed by Engineer-in-Charge.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints "laid in trenches or in floor", complete all as specified.
Excavation in post holes (or similar holes) in any type of soil, each not exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified.
Surface dressing n exc 15 cm deep in any type of soil complete all as specified.
M& L for hardcore broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C-2, using 40 mm graded stone aggregate, as in post hole filling and mass concrete including necessary form work all as specified and as directed by Engineer-in-charge.
M&L for Brickwork with fly ash bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 complete all as specified and as directed by Engineer -in-Charge
S&F for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 (vertical post -100mm bore, purlins and rafters - 80mm bore)
S&F rolled mild steel section as in main and cross beams, hip and jack, rafters, purlins, where connected to common, rafters and running rails and guides for sliding doors: fixed with angle cleats or other connecting plates conforming to grade Fe410-W (Gde E-250) quality 'B' all as specified
M&L for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpa as in roof overing/ cladding to wall, fixed with self tapping screws etc complete all as specified & directed by Engineer-in-Charge.
Preparation of new steel surfaces of any description over 10 cm in width or girth not otherwise described and apply two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
M&L for Preparation of new treated surfaces of walls and applying two coats of cement base paint complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; and getting out in soft/loose soil for foundation, etc. Or for shafts, wells, cesspits, manholes, pier holes, etc. N exc 10 sq m on plan and n exc 1.5 m in depth and getting out, complete all as specified.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified.
M&L for chequerred cement concrete colour tiles 20 cm x 20 cm x 25mm thick with grey cement and pigment, set, jointed and pointed in neat cement slurry in floors including 15mm thick screed bed in CM (1:6) complete all as specified and as directed by Engineer-in-Charge.
S&F Rolled Mild steel in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) for Fe-410-W (Gde-E-250) quality-B complete all as specified and directed
S&F Bib taps, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, for bore dia of pipe 20mm, supplied complete all as specified
S&F stop valves, cast copper alloy, chromium plated, fancy type, screwed down, high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions, for bore dia of pipe 20mm, complete all as specified and directed by Engineer-in-Charge
S&F stop valves, cast copper alloy, chromium plated, fancy type, screwed down, high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions, for bore dia of pipe 15mm, complete all as specified and directed by Engineer-in-Charge
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqm not exc 4.0 Sqm each complete including making good disturbed portions of wall with new or old bricks , lintels cills etc in CM 1:4 complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.5 Sqm each including making good disturbed portions of wall with new or old bricks, lintels cills etc in CM 1:4 complete all as specified and directed.
S&F for anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed by Engineer-in-Charge.
S&F anodised aluminium door shutters, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified
S&F anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified
S&F 5.5 mm thick sheet glass, ordinary quality fixed to aluminium doors in squares exc 0.5 sqm in each pane complete all as specified and directed.
S&F 12mm thick prelaminated particle board, interior grade, prelaminated both side decorative choice lamination fixed to aluminium doors or similar works complete all as specified & directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks, or stainless steel wire staples all as specified & directed.
S&F Parliament hinges, 100 mm long aluminium alloy anodised and fixed, ISI marked complete all as specified and as directed by Engineer-in-Charge.
S&F 150 mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and as directed.
S&F 100 mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked for windows complete all as specified and as directed.
S&F extruded anodised aluminium alloy handle fabricated type of size 125 mm long ISI marked complete all as specified and as directed.
S&F 300 mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete all as specified and directed.
S&F extruded aluminium section door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified.
S&F 140mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor specified.
S&F Brass mortice lock verticle type 100mm long with 4 levers complete all as specified
Taking down carefully, copper / aluminium conductor unserviceable / perished point wiring (any type) for light/ fan/ light socket or power socket etc complete with fittings such as switches, sockets, ceiling roses, pendant holders, bracket holder, light fittings, regulators etc, including making good to disturbed surfaces of wall/floor etc, complete, all as specified & directed.
Taking down old and unserviceable sub main wiring of any size and description and removable the same from site and making good the disturbed surfaces/portion of wall complete, all as specified & directed.
M&L for Sub main wiring with two runs of 4.0 Sqmm single core FRLS PVC insulated unsheathed cable upto and including 1100 volts grade with multistranded copper conductor drawn through in and including PVC surface conduit or casing caping of 20/30mm, 2.0 mm wall thickness (ISI marked) with all fittings and fixing accessories, surface type on walls, roofs etc including one run of 4.00 Sqmm FRLS PVC insulated copper conductor for earth continuity wire in green color including taking down carefully existing copper submain wiring with PVC surface conduit or casing caping and making good disturbed surfaces complete all as specified & directed by Engineer-in-Charge. Note:- Two runs of copper conductor 4.0 sqmm and one run of 4.00 Sqmm copper earth wire including PVC casing caping will be measured and paid as one unit only.
M&L for Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 1.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in MS sunken box suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed multi stranded copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one light/fan/bell point controlled by one way switch, complete all as specified & directed.
All as per Srl item No. 91 here-in-above but for one 3/5 pin 5 Amps socket outlet on same board with other switches.
All as per Srl item No. 91 here-in-above but for one 3/5 pin 5 Amps socket outlet on independent board.
M&L for point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable 1100 volt grade, single core of 2.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling/false ceiling including cutting chases as required, terminated in MS sunken box suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed multi stranded copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one 3/5 pin socket outlet 16 Amps controlled by one switch on independent board, complete all as specified & directed. Notes for Srl Item No. 91 to 94 (i) Unit rate includes for cutting chases whereever required and sinking for boxes, making good to walls / floors etc., complete, including white wash / colour wash as directed. (ii) Uniform coding of wiring i.e red / yellow / blue for phase black for neutral and green for earth is to be maintained.
S&F in replacement switch socket combination outlet 2 in 1, 6 pin type, 5 and 15 Amp, flush type, multipurpose complete all as specified & directed.
S&F ceiling rose 5 amp, surface type 240 volts bakelite three terminal complete all as specified & directed.
S&F in replacement Switch piano flush type 5 Amps 240 Volt, single pole one way, complete all as specified & directed.
S&F in replacement switch socket combination outlet 2 in 1, 5 pin type, 5 Amp, flush type, multipurpose complete all as specified & directed.
S&F in replacement socket outlet 2 in 1, 5 pin type, 5 Amp, flush type, 240 volts polycarbonate body complete all as specified & directed.
S&F in replacement Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified & directed.
S&F in replacement distribution board double door SPN, 240 volts, 8 way powder coated, CRCA steel sheet constructed as per IS:8623, for surface mounting distribution board, factory made and tested complete, protection IP 36 complete all as specified and directed by Engineer-In-Charge.
S&F in replacement distribution board double door SPN, 240 volts, 4 way powder coated, CRCA steel sheet constructed as per IS:8623, for surface mounting distribution board, factory made and tested complete, protection IP 36 complete all as specified and directed by Engineer-In-Charge.
S&F in replacement MCB, single pole, (SP) 6 to 32 Amp, AC, 10 KA repturing capacity, ISI marked, 240 Volt, 'C' series, including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCB, single pole & neutral, (SPN) 32 Amp, AC, 10 KA repturing capacity, ISI marked 240 Volt, 'C' series, including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified & directed.
S&F Energy saving 10W LED bulk head luminaires, IP-65, oval shape, surface mounted with all other accessories prewired and making connections with copper flexible twisted twin cord of appropriate gauge and length, 230v, 50Hz complete all as specified & directed. Make. Havells, Cat Part No. RUGBYNEONFT10WLED760SSYMBOPC or equivalent in Philips/ Crompton/ Bajaj
Taking down existing wall mounted fan and fixing at same location after necessary repair and connecting upto including provision of PVC insulated twin core copper cable from connector to fan of suitable length complete all as specified.
Periodical maint of 750mm sweep fans such as greasing of bearing/bushes preparing surface of wall mounted fan by scraping out old existing paint with the help of emery paper/wire brush and painting with two coats of white synthetic enamel paint with spray machine rewriting MES Srl No with black paint in capital letters complete all as specified.
S&F Earthing of galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 metre below normal ground level, surrounded on all sides by 150mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to and including earth lead wire 4.0mm (8SWG) by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 40x8mm, 10cm long PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 15mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electrical plate No 3 of SSR Part-I (2009) including taking down old existing earthing complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr, including testing on completion, complete all as specified & directed. Note : (a) The cost of earth work, PCC pit of size shown in electrical plate No.3, funnel, watering pipe, wire mesh, charcoal, dust, common salt, 20mm bore medium grade watering pipe & 15mm bore light grade GI pipe as protection to earth lead wire etc shall be deemed included in the unit rate for earthing. (b) After completion, during testing, if the earth resistance equal or less 2 ohms is not obtained, earthing will be regenerated at no extra cost till the desired earth resistance is obtained.
S&F in replacement 1x7 W LED lamp complete all as specified and directed. Make: Havells Cat Part No. LHLDERUEML8X010 or equivalent in Philips/ Crompton/ Bajaj
S&F surface & wall mounted, LED batten, 20W, 230v, extruded aluminium provided for efficient heat dissipiation with polycarbonate diffuser and integrated electronic driver complete including connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified & directed.Make.Havells Cat Part No ENDURALINEARNEOBS20WLED865SPCWH or equivalent in Philips/ Crompton/ Bajaj etc.
Supply, laying and testing XLPE insulated, electric cable (heavy duty) with stranded aluminium conductor, 1100 volts grade, heavy duty cable, cross-sectional area 25 Sqmm 4 core laid in trenches or passing through pipes complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
M&L for 40mm bore Tubes, 'light grade', galvanised, for cable protection fixed on poles or laid in trenches under floor, ducts etc with fixing clamps, nuts, bolts etc complete all as specified and directed.
Brick well burnt locally available sub class 'B' laid over sand cushioning for mechanical cable protection in trenches with width of brick perpendicular to the length of cable, complete all as specified & directed by Engineer-in-Charge.
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and directed. Note:- Punned thickness of sand will be measured and paid.
JR CONSTRSTRUCTION CO.
NARESH KUMAR AND COMPANY
NATIONAL TRADING COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .