| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC | L1 | Accepted-AOC Bidder was technically and financially qualified for award of work | |
| 2 | L2₹12.7 L+₹95,730 (8.18%)Rejected-Finance T C 17 250 CHADIYARA ROAD POOJAPPURA TRIVANDRUM KERALA 695012 | THIRUVANANTHAPURAM | KERALA | 695012 | L2 | Rejected-Finance Financially not lowest | |
| 3 | L3₹13.5 L+₹1.8 L (15.6%)Rejected-Finance ERNAKULAM KERALA 682301 INDIA | ERNAKULAM | KERALA | 682301 | L3 | Rejected-Finance Financially not lowest | |
| 4 | L4₹15.1 L+₹3.4 L (28.8%)Rejected-Finance ASWATHY NIVAS MAMPAZHAKARA PERUMPAZUTHOOR NEYATTINKARA TRIVANDRUM KERALA 695126 | THIRUVANANTHAPURAM | KERALA | 695126 | L4 | Rejected-Finance Financially not lowest |
Tender Value
₹15.6 L
EMD Value
₹31,255
Closing Date
24 Jan 2024, 4:00 pmClosed
Project Engineer cum Estate Officer(I/C)
IISER,Maruthamala.p.o, vithura, Thiruvananthapuram
External Street lighting along the road at the rear side of Visitors Forest Retreat and at the rear side of Residence Area Childrens park at IISER, Thiruvananthapuram
2024_IISRT_791116_1
IISERTVM/EO/EM/237/40/2023-24
Open Tender
Electrical Works
Item Rate
90 days
IISER
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹31,255
6 Feb 2024
18 Jan 2024
25 Jan 2024
18 Jan 2024
24 Jan 2024
18 Jan 2024
Amount
Supply, installation, testing and commissioning of pre-wired LED post top lanterns consisting of lumen level not less than 3300lumens and not more than 45W power, the fixture should be powder coated diecast aluminium housing with clear diffuser, THD<10%, PF>=0.95, 3000K warm white,min 4KV surge protection, IP65 protection, conforms to IS 10322 Part 5 complete, including necessary interconnections and Earthing as required. (Approved Makes: Bajaj Cat No: ARIAN,Havells Cat No: RUBY,Philips BDP102 LED50/830 DS,KLITE KL-4523 Romania)
Supply, installation, testing and commissioning of pre-wired LED post top lantern with glare free indirect lighting consisting of lumen level not less than 3300lumens and not more than 45W power, the fixture should be powder coated diecast aluminium housing with clear diffuser, THD<10%, PF>=0.95, 4000K neutral white,min 4KV surge protection, IP65 protection, conforms to IS 10322 Part 5 complete, including necessary interconnections and Earthing as required. (Approved Makes: Bajaj Tenco BRIL,Havells Spirng6,,KLITE KL-4520 Gema)
Supply and installation of 4mtr high hot dip galvanised conical poles with 118 mm bottom dia & 75 mm top dia made up of 3mm thick HT steel sheet along with base plate of size 200X200X12mm thick along with foundation bolts and suitable reducer to mount the light fixture as mentioned in item no. (1) on reinforced cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation (as per the drawing attached) including excavation, refilling, finishing etc. and with 6A DP MCB , 3core x 1.5sqmm flexible PVC copper cable for interconnecting light fixture to the MCB, GI sheet for connecting cable gland, earthing etc as required. Make: Bajaj/RR ISPAT/Transrail
Supply and installation of 4mtr high hot dip galvanised conical poles on the existing foundation with 118 mm bottom dia & 75 mm top dia made up of 3mm thick HT steel sheet along with base plate of size 200X200X12mm thick with suitable reducer to mount the light fixture as mentioned in item no. (1) and with 6A DP MCB , 3core x 1.5sqmm flexible PVC copper cable for interconnecting light fixture to the MCB, GI sheet for connecting cable gland, earthing etc as required. Make: Bajaj/RR ISPAT/Transrail
Supply & fixing of copper bonded ground rod having min 100 micron of copper coating, diameter of min 14.2 mm with length 600 mm driven into earth with necessary interconnections from pole foundation to earth rod using min 600mm length 10swg Cu. wire. All the interconnections shall be done using stainless steel nut bolts.
Supply of FRLS XLPE power cable of 1.1 kV grade of following size as required.
4C x 6 sqmm Aluminium armoured cable (A2XFY)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. Direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC HUME/ METAL/DWC HDPE pipe as required.
Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1kV grade as required.
4core X 6 sq. mm(19mm)
AKSHITH ELECTRICALS
IDEAL DATACOM NETWORK AND ELECTRICAL SOLUTIONS PVT LTD
FI-TEC POWER SOLUTIONS PVT. LTD
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .