Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹34.2 Cr
EMD Value
₹34.2 L
Closing Date
17 Nov 2026, 11:00 am3d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
NBCC Bhawan
NBCC Bhawan
Construction and Development of Double Section School Building with Bal Vatika, 09 Unit Staff Quarters and other allied development work at Kendriya Vidyalaya, Barkatha, Distt. Hazaribagh, Jharkhand
NBCC/SBG/etender/2026/204~EWc8b2456a2d014f145f6dd774
NBCC/SBG/etender/2026/204
Open Tender-Domestic
Civil Works General
NBCC Bhawan
₹59,000
₹34.2 L
26 Oct 2026
26 Oct 2026
17 Nov 2026
26 Oct 2026
17 Nov 2026
ABSTRACT OF COST
THE PROPOSED CONSTRUCTION OF KENDRIYA VIDYALAYA CAMPUS AT BARKATHA,
DIST.- HAZARIBAGH, JHARKHAND
SL.NO. PARTICULARS AS PER AS PER DSR- AS PER NON
DSR-2023 (civil) 2025 SOR
1 School building ( G+3)
1.2 Internal Plumbing Works 19,95,281 11,14,791 31,10,072
1.3 Internal Electrical & ELV System Works 1,92,53,184 84,53,916 2,77,07,100
1.4 Internal Fire Fighting System 18,83,166 3,87,972 22,71,138
1.5 Signage Works 4,91,349 4,91,349
2 TYPE -III Quartter (Staff Qtr.) G+1 ( 1 Blocks)
2.2 Internal Plumbing Works 4,06,917 3,29,085 7,36,002
2.3 Internal Electrical & ELV Works 9,32,264 1,43,169 10,75,433
3 TYPE -V Quartter (Principal Quarter G+0)
3.2 Internal Plumbing Works 1,84,889 92,896 2,77,785
3.3 Internal Electrical & ELV Works 5,41,855 1,32,489 6,74,344
4 Site Development and E & M Works
4.02 Substation Building (civil works) 23,16,056 23,16,056
4.04 Boundary Wall & Gate Guard room 2,39,18,209 1,41,929.30 2,40,60,139
4.05 PCC Road , Pathway & Parking 1,31,66,743 1,31,66,743
4.06 Cycle Parking & Covered Pedestrain Shed 33,50,611 33,50,611
4.07 Drinking water kiosk 1,52,371 1,52,371
4.08 Assembly Stage, Sculpture pedestal 3,75,169 3,75,169
4.10 UG Tank with Pump room 1,00,000 Litre 28,87,485 28,87,485
4.11 Septic Tank For (Principal Quarter, Staff Quarter & School Building) 14,28,598 14,28,598
4.12 Landscaping & Horticulture Works 26,13,380 26,13,380
4.13 External Electrical & ELV Works 32,54,239.00 53,73,110 86,27,349
4.14 External Plumbing Works 1,06,68,751 13,31,672 1,20,00,423
4.15 External Firefighting Works 55,44,716.00 1,25,595 56,70,311
Add cost index 10% for Hazaribagh region as per CPWD OM no. 62(H)
Cost i/c GST after Multiplication with multiplying factor 0.973 as per the
CPWD circular on DSR items only 27,87,25,451 3,51,66,904 2,83,39,402 34,22,31,758
SubTotal Including GST [F] :- 34,22,31,758
Digitally signed by PRIYA
PROPOSED CONSTRUCTION OF KV SCHOOL BUILDING (G+3)
ABSTRACT OF COST - CIVIL WORKS
SOR-2023 NON SOR
Sl. No. SOR-2022 DESCRIPTION
A 2 EARTH WORKS 40,28,314.28 -
B 4 CONCRETE WORKS 30,54,193.81 -
C 5 REINFORCED CEMENT CONCRETE WORK 8,17,47,005.84 -
E 8 MARBLE & GRANITE WORK 45,98,271.94 -
K 21 ALUMINIUM WORK 5,826.75 -
L 22 WATER PROOFING 32,96,852.54 -
GRAND TOTAL 16,15,60,209
GRAND TOTAL 16,15,60,209
Digitally signed by PRIYA
BILL OF QUANTITY FOR KV SCHOOL BUILDING (G+3)
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
A 2.00 EARTH WORKS
1 2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding
30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated
earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
2 2.7 Earth work in excavation by mechanical means (Hydralic excavator/manual means)over areas (exceeding
30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated
earth, lead upto 50m and lift upto 1.5m, as directed by Engineer - in Charge
3 2.10 Excavating trenches of required width for pipes, cables, etc. including excavation for sockets, and dressing
of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning
the soil as required, in layers not exc
a 2.10.1 All kinds of soil.
i 2.10.1.2 Pipes, cables, etc. exceeding 80mm dia but not exceeding 300mm dia. Metre 100.00 352.15 35,215.00
4 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not
exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and
5 2.26. Extra for every additional lift of 1.5 m or part thereof in excavation /
banking excavated or stacked materials.
5.2 2.26.2 Ordinary or hard rock Cum 97.58 227.40 22,189.69
6 2.27 Supplying and filling in plinth with sand under floors, including watering,
ramming, consolidating and dressing complete. Cum 449.58 2123.75 9,54,791.00
7 2.28 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep
and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
i 2.28.1 All kinds of soil Sqm 1650.00 34.15 56,347.50
8 2.34 Supplying chemical emulsion in sealed containers including delivery as specified
i 2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% Litre 893.92 234.75 2,09,847
9 2.35 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the
cost of chemical emulsion) :
i 2.35.1.1 Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the
vertical surface of the substructure to a depth of 300mm including excavation channel along the wall &
rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration Metre 385.00 38.90 14,976.50
a) 2.35.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including
drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the
existing floor:
i 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration Sqm 192.50 310.05 59,684.63
TOTAL (Carried Over to Summary of Civil Works) 40,28,314.28 0.00
B 4.00 CONCRETE WORKS
1 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level :
a 4.1.6 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm
nominal size derived from natural sources) Cum 154.09 7178.75 11,06,196.92
b 4.1.8 1 :4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from
natural sources : 8 graded stone aggregate 40 mm nominal
size derived from natural sources) Cum 232.72 6812.00 15,85,280.08
2 4.3 Centering and shuttering including strutting, propping etc. and removal of form work for :
i 4.3.1 Foundations, footings, bases for columns. Sqm 229.44 392.15 89,974.90
3 4.11 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand
(zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural
4 4.12 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement Per 50 kg
as per manufacturer's specification. cement 49.00 18.15 889.35
5 4.13 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg
per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of
cloth lightly soaked in kerosene oil. Sqm 153.86 146.15 22,486.99
6 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6
graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size,
well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling &
dressing & finishing the top smooth. Sqm 231.00 749.30 1,73,088.30
TOTAL (Carried Over to Summary of Civil Works) 30,54,193.81 0.00
C 5.00 REINFORCED CEMENT CONCRETE WORK
1 5.9 Centering and shuttering including strutting, propping etc. and removal of form for :
a 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete. Sqm 1240.93 392.15 4,86,632.01
b 5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. Sqm 89.60 842.50 75,488.00
c 5.9.3 Suspended floors, roofs, landings, balconies and access platform. Sqm 5258.27 927.25 48,75,727.77
d 5.9.4 Shelves (Cast in situ) Sqm 146.63 927.25 1,35,961.89
e 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers Sqm 6511.09 736.40 47,94,763.24
f 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts. Sqm 3689.48 961.30 35,46,700.33
g 5.9.7 Stairs, (excluding landings) except spiral-staircases. Sqm 532.88 764.95 4,07,622.73
Digitally signed by PRIYA
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
h 5.9.15 Small lintels not exceeding 1.5 m clear span, moulding as in
cornices, window sills, string courses, bands, copings, bed
plates, anchor blocks and the like Sqm 1.67 392.15 653.58
i 5.9.16 Edges of slabs and breaks in floors and walls 0.00
j 5.9.19 Weather shade, Chajjas, corbels etc., including edges. Sqm 420.70 951.10 4,00,127.77
2 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding
all complete upto plinth level.
i 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg 135383.77 107.85 1,46,01,139.58
3 5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding
all complete above plinth level.
i 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg 261892.33 107.85 2,82,45,087.45
4 5.33.1 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced
cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland
Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS:
9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing
strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost
of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the 2369.09
following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in
design mix shall be payable separately. In case the cement content in design mix is more than 110% of the
specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear
the cost of extra cement.
a) 5.33.1 All works upto plinth level.
i 5.33.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum Cum 600.00 9504.75 57,02,850.00
b) 5.33.2 All works above plinth level upto floor V level.
i 5.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum Cum 1846.44 9860.40 1,82,06,612.33
TOTAL (Carried Over to Summary of Civil Works) 8,17,47,005.84 0.00
D 6.00 BRICK WORK
1 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and
i 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 172.73 7132.25 12,31,924.80
2 6.32 Brick work with clay flyash F.P.S. (non modular) brick of class designation
7.5 in superstructure above plinth level up to floor five level in :
i 6.32.2 Cement mortar 1 :6 (1 cement : 6 coarse sand) Cum 1434.70 9095.05 1,30,48,708.08
3 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks
of class designation 7.5 in superstructure above plinth level up to floor
3.1 6.13.2 Cement mortar 1 :4 (1 cement :4 coarse sand) Sqm 705.40 1123.80 7,92,728.01
4 6.15 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick
s Analysis Based Honey-comb brick work 250 mm thick with common burnt clay bricks
rate DSR 6.23 of class designation 7.5 in super structure above plinth level upto floor V
level with cement mortar 1 :4 (1 cement : 4 coarse sand). Sqm 96.00 2060.80 1,97,836.39
TOTAL (Carried Over to Summary of Civil Works) 1,53,52,515.73 0.00
E 8.00 MARBLE & GRANITE WORK
1 8.2 Providing and fixing 18mm thick gang saw cut ( premoulded and prepolished) machine cut for kitchen
platforms, vanity counters, window sills , facias and similar locations of required size of approved shade,
colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints
treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing,
moulding and polishing to edge to give high gloss finish etc. complete at all levels.
b) 8.2.2 Granite of any colour and shade
2 8.3.2 Providing edge moulding to 18 mm thick marble stone counters, Vanities
etc., including machine polishing to edge to give high gloss finish etc.
complete as per design approved by Engineer-in-Charge. (Granite work) metre 157.13 510.95 80,283.02
3 8.5 Extra for providing opening of required size & shape for wash basin/
kitchen sink in kitchen platform, vanity counter and similar location in
marble/ Granite/ stone work, including necessary holes for pillar taps etc.
including moulding, rubbing and polishing of cut edges etc. complete. Each 88.00 978.70 86,125.60
4 8.9.2 Stone tile (polished) work for wall lining over 12 mm thick bed of cement
mortar 1 :3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm
including pointing in white cement complete. Granite of any colour and shade Sqm 55.56 3617.55 2,00,991.08
5 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by
the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size
as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement
mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including
pointing in white cement mixed with pigment of matching shade complete.
TOTAL (Carried Over to Summary of Civil Works) 45,98,271.94 0.00
Digitally signed by PRIYA
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
F 9.00 WOOD, WPC & uPVC WORK
1 9.21.1 Providing and fixing ISi marked flush door shutters conforming to IS :
2202 (Part I) non-decorative type, core of block board construction
with frame of 1st class hard wood and well matched commercial 3 ply
veneering with vertical grains or cross bands and face veneers on both
faces of shutters: (35 mm thick including ISi marked Stainless Steel butt hingesn with necessary screws)
2 9.127.2 Providing & Fixing decorative high pressure laminated sheet of plain
I wood grain in gloss / matt/ suede finish with high density protective
surface layer and reverse side of adhesive bonding quality conforming to
IS : 2046 Type S, including cost of adhesive of approved quality. (1.0 mm thick) Sqm 462.25 897.30 4,14,772.44
3 9.23 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door
shutters (over all area of door shutter to be measured). Sqm 231.12 462.35 1,06,859.49
4 9.24.1 Extra for providing vision panel not exceeding 0.1 sqm in all type of
flush doors (cost of glass excluded) (overall area of door shutter to be
measured): Rectangular or square Sqm 202.10 199.15 40,248.22
5 9.26 Extra for cutting rebate in flush door shutters (Total area of the shutter to
6 9.70.2 Providing and fixing IS : 12817 marked stainless steel butt hinges with
stainless steel screws etc. complete : 100X58X1.90 mm Each 372.00 107.10 39,841.20
7 26.86 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid
door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-
60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non
toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC
solvent cement and screwed with full body threaded star headed SS screws having minimum frame density
of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive
strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A
category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in
position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of
Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Note: For WPC
solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be
acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this
account shall be made.
8 26.87 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door
shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium
carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity
index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N
(Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and
resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture
proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body
threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless
steel butt hinges and necessary S.S screws shall be paid separately)
9 9.48.2 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round
bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames
with rawl plugs screws etc. Kg 6097.68 238.35 14,53,382.03
10 9.96.2 Providing and fixing aluminium sliding door bolts, ISi marked anodised
(anodic coating not less than grade AC 10 as per IS : 1868), transparent
or dyed to required colour or shade, with nuts and screws etc. complete : (250x16 mm) Each 131.00 260.60 34,138.60
11 9.97 Providing and fixing aluminium tower bolts, ISi marked, anodised (anodic
coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed
to required colour or shade, with necessary screws etc. complete :
12 9.103 Providing and fixing bright finished brass 100 mm mortice latch and lock,
ISi marked, with six levers and a pair of anodised (anodic coating not less
than grade AC 10 as per IS : 1868) aluminium lever handles of approved
quality with necessary screws etc. complete. Each 6.00 868.95 5,213.70
13 9.82 Providing and fixing bright finished brass hanging type floor door stopper
with necessary screws, etc. complete. Each 205.00 121.65 24,938.25
14 9.165 Providing and fixing bright /matt finished Stainless Steel handles of
approved quality & make with necessary screws etc all complete.
15 9.84 Providing and fixing aluminium extruded section body tubular type
universal hydraulic door closer (having brand logo with ISi, IS : 3564,
embossed on the body, door weight upto 36 kg to 80 kg and door width
from 701 mm to 1000 mm), with double speed adjustment with necessary
accessories and screws etc. complete. Each 6.00 983.15 5,898.90
16 9.135 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using
wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.
16.1 9.135.2 With 12 mm mild steel U beading Sqm 230.04 1228.00 2,82,489.12
Digitally signed by PRIYA
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
17.00 9.147A Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC
multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum
wall thickness of 1. 70 mm for Series R 1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles
conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section
made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and
lnline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade
fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve
for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary
stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion
welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and
drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with
weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved
drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement
and cross sections
of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh /
Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per
design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately.
Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the
manufacturer for
(i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3
(ii) Sites with structure height more than 20m for all wind speeds
9.147.A4 Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for
roller track, wool pile, nylon rollers with SS 304 body.
17.01 9.147.A1.2 Using R3 series with frame (55 mm & above) x (40 mm & above) & sash (30 mm & above) x (55 mm &
above) with zinc alloy (zamak) powder coated handle on every panel along with multi-point locking system
17.02 9.147.C1.1 Fixed window/ ventilator without mullion/ transom. Using R1 series with frame (33 mm & above) x (35 mm &
above). (Height upto 0.90 metre) Sqm 38.34 8247.25 3,16,199.57
18 Providing and installing SGG Evolite Clear (ET 150) Single Glazed Unit (SGU), comprising 6 mm thick
coated glass with coating on Face 2, having a light transmission of 50%, external light reflection of 13%,
internal light reflection of 11%, Solar Heat Gain Coefficient (SHGC) of 0.50 and U-value of 5.0 W/m²K as per
EN 673, complete with all necessary glazing accessories, compatible sealants, labour, handling,
transportation and installation as per approved drawings and manufacturer's specifications.
Classroom Cup Boards & Full ht. Storage
19 9.131.1 Providing and fixing factory made shutters of Pre-laminated particle
board flat pressed three layer or graded wood particle board with one
side decorative finish and other side balancing lamination conforming
to IS: 12823 Grade I Type 11, of approved design, and edges sealed with
water resistant paint and lipped with aluminium 'U' type edge beading
all- round the shutter, including fixing with angle cleat, grip strip, cadmium
plated steel screws, including fixing of aluminium hinges 100x63x4 mm
etc. complete as per architectural drawing and direction of Engineer-inCharge
(Cost of 'U' beading and hinges will be paid for separately).
20 9.167 Providing and fixing 6 mm thick both sides Pre-laminated cement
bonded wood particle board as per IS : 15786:2008 of approved brand
and shade with suitable full threaded steel screws etc. on the backing of
racks, drawer, cupboard, kitchen cabinet under kitchen counter etc. all
complete as per direction of Engineer-in-charge. Sqm 35.16 1010.60 35,532.70
21 9.166.1 Providing and fixing 18 mm thick both sides Pre-laminated cement
bonded wood particle board as per IS : 15786:2008 of approved brand
and shade with suitable full threaded steel screws etc. in partitions, boxes,
shelves, racks and cupboard, kitchen cabinet under kitchen counter etc.
all complete as per direction of Engineer-in-charge (Note: Fittings to be
paid separately).
22 9.170.1 Providing and fixing stainless steel fancy handle of approved make fixed
with SS screws etc. complete as per direction of Engineer-in-charge. (200mm) Each 196.00 186.65 36,583.40
23 9.171 Providing and fixing stainless steel soft closing spring hinges at 0 degree
hinges (hydraulic type) of approved make/brand to cupboard shutters
with full threaded steel screws including making necessary recess in
board and finished etc. complete as per direction of Engineer-in-charge. Each 316.00 272.00 85,952.00
TOTAL (Carried Over to Summary of Civil Works) 95,87,004.76 15,37,825.98
G 10.00 STEEL WORK
1 10.3 Providing and fixing in position collapsible steel shutters with vertical
channels 20x1 0x2 mm and braced with flat iron diagonals 20x5 mm
size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia
steel pulleys, complete with bolts, nuts, locking arrangement, stoppers,
handles, including applying a priming coat of approved steel primer. Sqm Rate only 11439.60 0.00
2 10.5.1 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset
plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of
approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces. Sqm 7.56 5804.35 43,880.89
Digitally signed by PRIYA
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
3 10.6 Supplying and fixing rolling shutters of approved make, made of required
size M.S. laths, interlocked together through their entire length and jointed
together at the end by end locks, mounted on specially designed pipe
shaft with brackets, side guides and arrangements for inside and outside
locking with push and pull operation complete, including the cost of
providing and fixing necessary 27.5 cm long wire springs manufactured
from high tensile steel wire of adequate strength conforming to IS: 4454 -
part 1 and M.S. top cover of required thickness for rolling shutters.
3.1 10.6.1 80x1 .25 mm M.S. laths with 1.25 mm thick top cover Sqm 5.76 3653.20 21,042.43
4 10.15.1 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-
Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of
required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved
steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm
of C.C. 1 :3:6 (1 Cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)
5 10.18 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140
mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid
shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock
at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
6 10.25 Steel work welded in built up sections/ framed work, including cutting,
hoisting, fixing in position and applying a priming coat of approved steel
primer using structural steel etc. as required.
a 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works KG 8210.00 172.60 14,17,046.00
7 10.27 Providing and fixing carbon steel galvanised ( minimum coating 5 micron)
dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480
N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6
grade sleeve, including drilling of hole in frame , concrete/ masonry, etc.
as per direction of Engineer-in-charge.
8 MR-2 Providing, fabricating and fixing of M.S. decorative grill as per design comprising of 16 mm square M.S. rod/
flat/ square bar with frame and supports, covered with 3 mm thick M.S. laser-cut sheet, including cutting,
welding, grinding, edge finishing, fixing in position with necessary clamps/fasteners, and applying one coat of
suitable metal primer, complete in all respects as per approved design and drawing.
TOTAL (Carried Over to Summary of Civil Works) 18,68,082.54 7,04,996.54
H 11.00 FLOORING WORK
1 11.26.1 Kota stone slab flooring over 20 mm (average) thick base laid over and
jointed with grey cement slurry mixed with pigment to match the shade of
the slab, including rubbing and polishing complete with base of cement
mortar 1 : 4 (1 cement : 4 coarse sand) :
2 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars
laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse
sand) and jointed with grey cement slurry mixed with pigment to match
the shade of the slabs, including rubbing and polishing complete. Sqm 378.11 2354.70 8,90,327.38
3 11.31 Extra for pre finished nosing in treads of steps of Kata stone/ sand stone
4 11.32 Extra for Kata stone/ sand stone in treads of steps and risers using single
length above normal size up to 2.00 metre. Sqm 172.80 44.15 7,629.12
4 DSR- 11.41A Providing and laying Vitrified tiles in floor in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08% and
conforming to IS: 15622, of approved brand & manufacturer, in all colours
and shade, laid on 20 mm thick cement mortar 1 :4 (1 cement: 4 coarse
sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the
joints with white cement and matching pigments etc. The tiles must be cut
with the zero chipping diamond cutter only . Laying of tiles will be done
with the notch trowel, plier, wedge, clips of required thickness, leveling
system and rubber mallet for placing the tiles gently and easily.
4.1 11.41A.1.3 Double charge vitrified tile polished finish of size (Size of Tile 600 x 1200 mm) Sqm 518.53 1577.15 8,17,798.60
4.2 11.41A.3.1 Glazed Vitrified tiles MatUAntiskid finish of size (Size of Tile 600 x 600 mm) Sqm 453.29 1464.85 6,63,995.45
5 MR-3 Providing and fixing 15 mm thick acid resistant tiles of approved make, size 800 × 2400 mm, on prepared
surface using approved high polymer modified/acid resistant tile adhesive, including preparation and cleaning
of surface, application of adhesive of required thickness, cutting and fitting of tiles to required size and
shape, maintaining proper line, level and alignment, filling and sealing of joints with suitable acid-resistant
epoxy/chemical-resistant grout, complete in all respects as per manufacturer’s specifications and as directed
by the Engineer-in-Charge. Sqm 12.75 3592.53 45,804.76
6 11.48 Grouting the joints of flooring tiles having joints of 3 mm width, using
epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10
kg of hardener and 0.20 kg of resin per kg), including filling / grouting and
finishing complete as per direction of Engineer-in-charge.
Digitally signed by PRIYA
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
7 11.55.1 Providing and laying flamed finish Granite stone flooring in required
design and patterns, in linear as well as curvilinear portions of the building
all complete as per the architectural drawings with 18 mm thick stone
slab over 20 mm (average) thick base of cement mortar 1 :4 (1 cement: 4
coarse sand) laid and jointed with cement slurry and pointing with white
cement slurry admixed with pigment of matching shade including rubbing,
curing and polishing etc. all complete as specified and as directed by the
Engineer-in-Charge :
Flamed finish granite stone slab Jet Black, Cherry Red, Elite
Brown, Cat Eye or equivalent. Sqm 118.21 3186.70 3,76,683.87
8 11.56 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as
curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab
over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with
cement slurry and pointing with white cement slurry admixed with pigment of matching shade including
rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
11.56.1 Polished Granite stone slab jet black,cherry Red ,Elite Brown,Cat Eye or equivalent sqm 137.50 4481.30 6,16,178.75
9 16.68 Providing and laying 60 mm thick faciory made cement concrete
interlocking paver block of M -30 grade made by block making machine
with strong vibratory compaction, of approved size, design & shape, laid
in required colour and pattern over and including 50 mm thick compacted
bed of coarse sand, filling the joints with line sand etc. all complete as per
the direction of Engineer-in-charge. sqm 684.20 972.00 6,65,042.40
10 16.89 Providing and laying matt finished vitrified tile of size 300x300x9.8 mm
having with water absorption less than 0.5% and conforming to IS: 15622
of approved make in all colours and shades in for outdoor floors such as
footpath, court yard, multi modals location etc., laid on 20 mm thick base
of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns
including grouting the joints with white cement mixed with matching
pigments etc. complete as per direction of Engineer-in-Charge. Sqm 68.37 1455.65 99,522.79
TOTAL (Carried Over to Summary of Civil Works) 1,38,29,238.73 45,804.76
I 12.00 ROOFING
1 12.21 Providing and laying gola 75x75mm in cement concrete M15 grade including finishing with cement mortar 1:3
(1 cement : 3 fine sand) as per standard design in 75x75 mm deep chase. rmt. 309.00 305.15 94,291.35
2 12.55 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm
x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70
and initial emittance> 0.75 on waterproof and sloped surface of terrace,
laid on 20 mm thick cement sand mortar in the ratio of 1 :4 (1 cement : 4
coarse sand) and grouting the joints with mix of white cement & marble
powder in ratio of 1 :1, including rubbing and polishing of the surface upto
3 cuts complete, including providing skirting upto 150 mm height along
the parapet walls in the same manner. Sqm 350 1703.95 5,96,382.50
3 12.45 Providing and fixing false ceiling at all heights including providing and
fixing of frame work made of special sections, power pressed from M.S.
sheets and galvanized with zinc coating of 120 gms/sqm (both side
inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm
wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre
to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia
x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle
hangers of 25x1 0x0.50 mm of required length with nuts & bolts of required
size and other end of angle hanger fixed with intermediate G.I. channels
45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to
which the ceiling section 0.5 mm thick bottom wedge of 80 mm with
tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre
to centre, shall be fixed in a direction perpendicular to G.I. intermediate
channel with connecting clips made out of2.64 mm dia x 230 mm long G.I.
wire at every junction, including fixing perimeter channels 0.5 mm thick
27 mm high having flanges of 20 mm and 30 mm long, the perimeter of
ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre,
with 25 mm long dry wall screws@ 230 mm interval, including fixing of
gypsum board to ceiling section and perimeter channel with the help of
dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and
finishing to a flush finish of tapered and square edges of the board with
recommended jointing compound , jointing tapes , finishing with jointing
compound in 3 layers covering upto 150 mm on both sides of joint and two
coats of primer suitable for board, all as per manufacturer's specification
and also including the cost of making openings for light fittings, grills,
diffusers, cutouts made with frame of perimeter channels suitably fixed,
all complete as per drawings, specification and direction of the Engineer
in Charge but excluding the cost of painting with :
3.1 12.45.3 12.5 mm thick tapered edge gypsum moisture resistant board Sqm 362.68 1529.10 5,54,568.25
TOTAL (Carried Over to Summary of Civil Works) 12,45,242.10 0.00
J 13 FINISHING WORK
1 13.4 12 mm cement plaster of mix :
2 13.5 15 mm cement plaster on rough side of single or half brick wall of mix:
Digitally signed by PRIYA
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
3 5.30 Add or deduct for plaster drip course/ groove in or moulding to R.C.C. projections.plastered surface Metre 1412.60 78.40 1,10,747.84
4 13.16 6 mm cement plaster of mix :
4 13.21 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by per bag of
the manufacturers. 50KG
5 13.26 Providing and applying plaster of paris putty of 2 mm thickness over
plastered surface to prepare the surface even and smooth complete. Sqm 153.75 262.70 40,389.47
6 13.83.2 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound
) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats
wherever required to achieve even shade and colour. Two coats Sqm 18927.86 142.80 27,02,898.71
7 13.85.3 Applying priming coats with primer of approved brand and manufacture,
having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface
having VOC content less than 50 grams/litre Sqm 18774.11 73.95 13,88,345.77
8 13.45.1 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28
ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm Sqm 4546.51 223.60 10,16,599.41
9 13.47 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
i 13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer
10 MR-4 Providing and applying premium quality decorative exterior textured paint finish having natural Travertine
Stone Effect* on external plastered/RCC wall surfaces, using an approved weather-resistant, water-based
acrylic/polymer-modified decorative texture coating system, including: Sqm 483.67 1411.58 6,82,740.47
11 13.50 Applying priming coat :
ii 13.50.3 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised
iron/ steel works Sqm 1706.78 67.40 1,15,036.90
12 13.62 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even
i 13.62.1 Two or more coats on new work over an under coat of suitable
shade with ordinary paint of approved brand and manufacture Sqm 1706.78 226.25 3,86,158.75
13 13.68.1 French spirit polishing : Two or more coats on new works including a coat of wood filler Sqm 554.69 446.25 2,47,532.20
Expansion joints
14 5.28 Providing and fixing in position 12 mm thick bitumen impregnated fiber. board conforming to IS: 1838, per cm
including cost of primer, sealing compound Grade-A in expansion joints. depth per
15 5.29.2.1 Providing and fixing sheet covering over expansion joints with iron screws
as per design. Aluminium fluted strips 3.15 mm thick. (150 mm wide) Rmt 161.00 567.60 91,383.60
16 26.91 Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain
white colour board Jali, CNC (Computer numeric control) routed of approved design by Engineer-in -charge
which are machine cut for duct/shaft covering, partitions and facades comprising of virgin polymer of K value
58-60 (Suspension Grade), calcium corbonate and natural fibers (wood powder/ rice husk/ wheat husk) and
non toxic additives(maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and
screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2, modulus of elasticity
850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer
proof, water/ moisture proof and fire retardant and fixing on M.S (mild steel) frame made of 25 x 25 x 1.5 mm
square hollow box section including applying a priming coat of approved steel primer, placed at grid made at
1.0 x 1.0 m or as per requirement at site with necessary stainless steel fasteners and SS screws etc., all
complete as per direction of Engineer-In- Charge. Note: M.S (mild steel) framework with priming coat and
necessary SS fasteners and SS screws shall be paid separately.
17 MR-5 Providing, fitting and fixing customised artistic wall mural on building wall using glass mosaic tesserae of
nominal size 20 mm × 20 mm × 4 mm thick, of approved quality, colours, shades, textures and finish,
arranged to reproduce the approved artist’s image, composition and colour scheme, including preparation of
scaled working drawings, colour mapping, numbered installation panels and approved sample; preparation of
sound wall substrate, cleaning, removal of loose material, local repairs and minor surface levelling; supplying
and applying approved white polymer-modified adhesive specifically suitable for glass mosaic and the
specified wall exposure, with compatible primer wherever required; positioning, cutting, shaping, aligning and
firmly bedding mosaic pieces to achieve full adhesive contact; filling joints with approved compatible grout in
selected colours; providing flexible sealant at movement joints, perimeters and junctions as detailed;
finishing edges and corners, removing mounting paper/film where applicable, cleaning and protecting the
completed mural, replacing defective pieces and making good adjoining surfaces; including all materials,
skilled mosaic-artisan labour, tools, equipment, carriage, handling, wastage, staging, scaffolding, working
platforms, safety arrangements and their dismantling at the locations and heights indicated in the drawings,
complete as per approved artwork, specifications and directions of the Engineer-in-Charge.
18 MR-6 Providing and fixing 24 gauge Chicken Wire mesh in junction of block work & RCC works at corner/wall
surface as per direction of Engineer-In-Charge. Sqm 38.50 266.86 10,274.11
Digitally signed by PRIYA
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
19 MR-7 Providing, fabricating, supplying and fixing factory-manufactured, kiln-fired terracotta jali modules, nominal
size 205 × 205 mm, or other sizes, thicknesses and patterns specified in the approved drawings, including
four-petal, diagonal, geometric or combination designs, of approved quality, shade and manufacture, free
from cracks, distortion and defective edges; assembled in panels within purpose-designed mild steel
supporting framework, comprising perimeter frames, intermediate horizontal and vertical members, angles,
channels, flats, hollow sections, brackets, bearing supports and retaining members of sizes and thicknesses
as per approved structural and shop drawings. Sqm 168.37 5105.21 8,59,551.21
20 MR-8 Providing and fixing factory-made modular toilet cubicle system comprising 12 mm thick compact high-
pressure laminate (HPL) partition panels, pilasters and doors, in approved colour with suede finish, including
doors of size 600 × 1785 mm, divider height 1820 mm and overall height 1995 mm, including 150 mm floor
clearance, with nylon adjustable feet, gravity hinges, coat hooks, door knobs and thumb-turn occupancy
indicators; aluminium U-channels, door-stopper channels and top rails; all screws, wall plugs, noise tape and
necessary fittings, including cutting, drilling, edge finishing, transportation, unloading, shifting, installation and
alignment, complete as per approved drawings, manufacturer’s recommendations and directions of Engineer-
in-Charge. Make: Greenlam Sturdo Essentia Serene or approved equivalent.
TOTAL (Carried Over to Summary of Civil Works) 1,73,21,962.04 33,37,070.81
K 21.00 ALUMINIUM WORK
1 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up
standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733
and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including
necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc.
Aluminium sections shall be smooth, rust free, straight, mitred and jointed echanically wherever required
including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all
complete as per architectural drawings and the directions of Engineer-in-charge. Glazing and paneling to be
paid for separately) :
a) 21.1.1 For fixed portion.
i 21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) KG 5.00 530.90 2,654.50
b 21.1.2 For shutters of doors, windows & ventilators including
providing and fixing hinges/ pivots and making provision
for fixing of fittings wherever required including the cost of
EPDM rubber / neoprene gasket required (Fittings shall be
paid for separately)
1 21.1.2.2 Powder coated aluminium (minimum
thickness of powder coating 50 micron) KG 5.00 634.45 3,172.25
2 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM
rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-
charge . (Cost of aluminium snap beading shall be paid in basic item):
i 21.3.2 With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) Sqm 0.00 1505.25 0.00
TOTAL (Carried Over to Summary of Civil Works) 5,826.75 0.00
L 22.00 WATER PROOFING
1 22.3 Providing and laying water proofing treatment to vertical and horizontal
surfaces of depressed portions of W.C., kitchen and the like consisting of:
(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water
proofing compound conforming to IS : 2645 in recommended proportions
including rounding off junction of vertical and horizontal surface.
(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand)
mixed with water proofing compound in recommended proportion
including rounding off junction of vertical and horizontal surface.
(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7
kg. per sqm of area.
(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of
PVC sheet should be 100 mm wide and pasted to each other with bitumen
Digitally signed by PRIYA
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
2 22.7 Providing and laying integral cement based water proofing treatment
including preparation of surface as required for treatment of roofs,
balconies, terraces etc consisting of following operations:
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement
admixed with water proofing compound conforming to IS. 2645 and
approved by Engineer-in-charge over the RCC slab including adjoining
walls upto 300 mm height including cleaning the surface before treatment.
(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm
to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse
sand) admixed with water proofing compound conforming to IS : 2645
and approved by Engineer-in-charge over 20 mm thick layer of cement
mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-in-charge
to required slope and treating similarly the adjoining walls upto 300 mm
height including rounding of junctions of walls and slabs.
(c) After two days of proper curing applying a second coat of cement slurry
using 2.75 kg/ sqm of cement admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge.
(d) Finishing the surface with 20 mm thick jointless cement mortar of mix
1:4 (1 cement :4 coarse sand) admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge including
laying glass fibre cloth of approved quality in top layer of plaster and
finally finishing the surface with trowel with neat cement slurry and making
pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for
a minimum period of two weeks for curing and for final test. “All above operations to be
done in order and as directed and specified by the Engineer-in-Charge”:
2.01 22.7.1 With average thickness of 120 mm and minimum thickness
TOTAL (Carried Over to Summary of Civil Works) 32,96,852.54 0.00
ALL SUB-HEAD TOTAL 15,59,34,511.06 56,25,698.09
GRAND TOTAL 16,15,60,209
GRAND TOTAL 16,15,60,209
Digitally signed by PRIYA
PROJECT: PROPOSED KENDRIYA VIDYALAYA CAMPUS AT BARKATHA, DIST.- HAZARIBAGH, JHARKHAND
MAIN SCHOOL BUILDING (G+3)
DETAILED ESTIMATE OF INTERNAL PLUMBING
Amount as per Amount as
S.No. DSR -2023 / NS Description Unit Qty. Rate (Rs.)
DSR (Rs.) per MR (Rs.)
Sub- Head - ( I ), Sanitary Fixture & CP Fittings
1 DSR-17.1 Providing and fixing water closet squatting pan (Indian type
W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low
fixtures complete, including cutting and making good the walls
andlevel white P.V.C. flushing cistern, including flush pipe, with
manually controlled device (handle lever) conforming to IS :
7231, with all fittings and floors wherever required :
DSR-17.1.1 White Vitreous china Orissa pattern W.C. pan of size
580x440 mm with integral type foot rests Each 10 6767.4 67,674.00
2 DSR-17.3 Providing and fixing white vitreous china pedestal type water
closet (European type) with seat and lid, 10 litre low level white
vitreous china flushing cistern & C.P. flush bend with fittings &
C.I.brackets, 40 mm flush bend, overflow arrangement with
specials of standard make and mosquito proof coupling of
approved municipal design complete, including painting of
fittings and brackets, cutting and making good the walls and
floors wherever required :
DSR-17.3.1 W.C. pan with ISI marked white solid plastic seat and lid Each 65 8006.6 5,20,429.00
3 DSR-17.4 Providing and fixing white vitreous china flat back or wall corner
type lipped front urinal basin of 430x260x350 mm and
340x410x265 mm sizes respectively with automatic flushing
cistern with standard flush pipe and C.P. brass spreaders with
brass unions and G.I clamps complete, including painting of
fittings and brackets, cutting and making good the walls and
floors wherever required :
DSR-17.4.2 One urinal basin with 5 litre white P.V.C. automatic flushing
DSR-17.4.2 Range of two urinal basins with 5 litre white P.V.C. automatic
flushing cistern Each 4 9612.4 38,449.60
DSR-17.4.3 Range of three urinal basins with 10litre white P.V.C. automatic
flushing cistern Each 4 13417.3 53,669.20
DSR-17.4.4 Range of four urinal basins with 10 litre white P.V.C. automatic
flushing cistern Each 7 18759.95 1,31,319.65
4 DSR-17.7 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP
Brass single hole basin mixer of approved quality and make,
including painting of fittings and brackets, cutting and making
good the walls wherever required:-
(a) White Vitreous China Wash basin size 550x400 mm
with a 15 mm CP Brass single hole basin mixer Each 7 3960.55 27,723.85
5 DSR-18.22 Providing and fixing C.P. brass shower rose with 15 or 20 mm
DSR-18.22.1 150 mm diameter Each 17 222.35 3,779.95
6 DSR-17.31 Providing and fixing 600x450 mm beveled edge mirror of
superior glass (of approved quality) complete with 6 mm thick
hard board ground fixed to wooden cleats with C.P. brass screws
and washers complete. Each 99 1607.95 1,59,187.05
7 DSR-17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm
long, 200 mm wide with minimum distances of 37 mm from wall
face with concealed fittings arrangement of approved quality
and colour,weighing not less than 88 gms.
8 DSR-17.73 Providing and fixing PTMT towel rail complete with brackets
fixed to wooden cleats with CP brass screws with concealed
fittings arrangement of approved quality and colour.
DSR-17.73.2 600 mm long towel rail with total length of 645 mm, width
78 mm and effective height of 88 mm, weighing not less
9 DSR-18.65 Providing and fixing PTMT soap Dish Holder having length of
138mm,breadth 102mm, height of 75mm with concealed fitting
arrangements,weighing not less than 106 gms.
Digitally signed Page 1 of 5
Amount as per Amount as
S.No. DSR -2023 / NS Description Unit Qty. Rate (Rs.)
DSR (Rs.) per MR (Rs.)
10 DSR-17.71 Providing and fixing PTMT liquid soap container 109 mm
wide,125 mm high and 112 mm distance from wall of standard
shape with bracket of the same materials with snap fittings of
approved quality and colour, weighing not less than 105 gms.
11 DSR/17.22B Providing and fixing CP Brass Single lever telephonic wall mixer
of quality & make as approved by Engineer in charge.
(a) 15 mm nominal dia Each 17 6940.75 1,17,992.75
12 DSR/17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin
including P.V.C. waste fittings complete.
DSR/17.28.2 Flexible pipe
13 DSR/17.69 Providing and fixing PTMT Waste Coupling for wash basin and
sink, of approved quality and colour.
DSR/17.69.1 Waste coupling 31 mm dia of 79 mm length and 62mm breadth
weighing not less than 45 gms Each 7 115.3 807.10
DSR/17.70 Providing and fixing PTMT Bottle Trap for Wash basin and sink.
DSR/17.70.1 Bottle trap 31mm single piece moulded with height of 270 mm,
effective length of tail pipe 260 mm from the centre of the
waste coupling, 77 mm breadth with 25 mm minimum water
seal, weighing not less than 260 gms. Each 99 367.1 36,342.90
15 DSR/18.49 Providing and fixing C.P. brass bib cock of approved quality
conforming to IS:8931 :
DSR/18.49.1 15 mm nominal bore Each 92 506.8 46,625.60
16 DSR/18.53 Providing and fixing C.P. brass angle valve for basin mixer and
geyser points of approved quality conforming to IS:8931
DSR/18.53.1 15 mm nominal bore Each 184 574.3 1,05,671.20
17 NS Providing, fixing, testing and commissioning of heavy duty chrome
plated brass health faucet conforming to relevant IS/CPWD
specifications, comprising trigger operated hand spray, SS braided
flexible hose of 1.2 m length, wall bracket, 15 mm CP brass angle
valve with wall flange, complete with all accessories, connection to
water supply line, cutting/chasing, making good the wall and
testing complete in all respects.
Approved Make: Jaquar / Hindware / Cera / Kohler / Parryware /
Equivalent approved.
18 NS Providing and fixing white vitreous china counter top wash basin of
approved make, conforming to IS 2556 (Part 4), of size
approximately 550 × 400 mm and 15mm dia CP Pillar tap, complete
with 32 mm dia CP brass waste coupling, cutting/opening in
counter wherever required, fixing with approved sealant, making
good the counter, testing and commissioning complete in all
respects as directed by the Engineer-in-Charge.
Approved Make: Jaquar / Kohler / Hindware / Cera / Parryware /
Equivalent approved.
19 NS Providing and fixing 680 mm long vertical grab bar made of 32 mm
dia stainless steel (SS 304) pipe with satin finish, including
mounting flanges, stainless steel screws, fasteners and necessary
accessories, securely fixed to the wall in the accessible toilet for
persons with disabilities, complete in all respects as directed by the
Engineer-in-Charge.
Approved Make: Jaquar / Hindware / Cera / Parryware / Equivalent
approved. Each 7 4409.00 30,863.00
20 NS Providing and fixing vertical swing grab bar, approximately 738 mm
long × 300 mm wide × 100 mm projection, fabricated from 32 mm
dia AISI 304 stainless steel tube with satin finish, including 3 mm
thick wall-mounting plate, hinged swing-up mechanism with
vertical locking arrangement, six-point wall fixing and necessary
fasteners, complete as directed by the Engineer-in-Charge.
Approved Make: Jaquar / Hindware / Cera / Parryware / Equivalent
Sub- Head - ( II ), Soil, Waste, Vent & Rain Water pipe
Digitally signed Page 2 of 5
Amount as per Amount as
S.No. DSR -2023 / NS Description Unit Qty. Rate (Rs.)
DSR (Rs.) per MR (Rs.)
1 MR Supply fixing and testing UPVC SWR pipe confirming to IS:13592
for waste connection from wash basin and pantry sink to floor
trap or thermosyphonage pipe with solvent cement joints
including all the fittings laid above the fall ceilling connected in
wall etc the shall include wall chiseling making good the same in
cement mortar etc complete include with all necessary support
like GI hangers support GI grip and bolts GI clamp etc in fall
ceilling area as well as supplying and fixing GI slotted angle iron
bracket hangers supports with necessary drilling holes to suit
the insertion of pipe clamps deburring brick work concrete
supports etc as per detailed drawing for supporting soil waste
and rain water pipes and water supply pipes in shaft with
suitable GI clamps GI bolts anchor nuts and washers fixed on
shaft walls, outer walls etc.
2 MR Providing and fixing M.S. holder bat clamps of approved design
including cost of cutting holes and making good the walls etc.
3 MR Providing fixing and testing UPVC SWR plain ring type 90 Deg
Bend with door IS:14735
4 MR Providing fixing and testing UPVC SWR plain ring type 45 Deg
5 MR Providing fixing and testing UPVC SWR plain Single Y Branch
with Door type fitting IS:14735
6 MR Providing fixing and testing UPVC SWR plain Reducing Single Y
Branch Door type fitting IS:14735
7 MR Providing fixing and testing UPVC SWR plain Tee Branch with
Door type fitting IS:14735
8 MR Providing and fixing and testing UPVC single floor trap with all
necessary UPVC pipes connection extension pipe and reducing
tee for water pipe connections from toilet and wash area.
8 MR Providing and fixing 75 mm dia, 3 mm thick Stainless steel
grating with frame for floor traps or drains of required pattern
including cutting and making good the floors complete.
9 DSR /4.1 Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering - All work
up to plinth level:
DSR /4.1.3 1:2:4 (1 cement :2 coarse sand: 4 hard stone aggregate 20mm
and down gauge). Cum 2.00 7878.5 15,757.00
10 DSR/12.22 Making khurras 45x45 cm with average minimum thickness of 5
cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m
x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1
cement : 3 coarse sand) and a coat of neat cement, rounding the
edges and making and finishing the outlet complete.
11 DSR /12.41 Providing and fixing on wall face unplasticised Rigid PVC rain
water pipes conforming to IS : 13592 Type A, including jointing
with seal ring conforming to IS : 5382, leaving 10 mm gap for
thermal expansion, (i) Single socketed pipes.
Digitally signed Page 3 of 5
Amount as per Amount as
S.No. DSR -2023 / NS Description Unit Qty. Rate (Rs.)
DSR (Rs.) per MR (Rs.)
DSR /12.41.2 110 mm diameter Metre 200 377.4 75,480.00
12 DSR /12.42 Providing and fixing on wall face unplasticised - PVC moulded
fittings/ accessories for unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for thermal
DSR /12.42.1 Coupler
DSR /12.42.3 Single tee with door
DSR /12.42.5 Bend 87.5
13 DSR /12.43 Providing and fixing unplasticised -PVC pipe clips of approved
design to unplasticised - PVC rain water pipes by means of
50x50x50 mm hard wood plugs, screwed with M.S. screws of
required length, including cutting brick work and fixing in
cement mortar 1:4 (1 cement : 4 coarse sand) and making good
the wall etc. complete.
14 DSR /12.44 Providing and fixing to the inlet mouth of rain water pipe cast
iron grating 15 cm diameter and weighing not less than 440
grams. Each 10 54.7 547.00
15 DSR-18.58 Providing and fixing PTMT grating of approved quality and
18.58.1 Circular type
16 N.S Providing, fixing, testing & commisioning of cast iron cleanout
plug with suitable insetkeys for opening male threaded joint
with G.I. socket caulked to HCI soil pipe pipe including cost of
joint material.
Sub- Head - ( III ), Internal Water Supply
1 DSR /18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all
CPVC plain & brass threaded fittings, including fixing the pipe
with clamps at 1.00 m spacing. This includes jointing of pipes &
fittings with one step CPVC solvent cement and testing of joints
complete as per direction of Engineer in Charge.
Internal work - Exposed on wall
DSR /18.7.1 15 mm nominal outer dia Pipes Metre 286.8 -
DSR /18.7.2 20 mm nominal outer dia Pipes Metre 335 -
DSR /18.7.3 25 mm nominal outer dia Pipes Metre 20 401.55 8,031.00
DSR /18.7.4 32 mm nominal outer dia Pipes Metre 75 518.55 38,891.25
DSR /18.7.5 40 mm nominal outer dia Pipes Metre 702.95 -
DSR /18.7.6 50 mm nominal outer dia Pipes Metre 934.15 -
2 DSR /18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all
CPVC plain & brass threaded fittings, i/c fixing the pipe with
clamps at 1.00 m spacing. This includes jointing of pipes &
fittings with one step CPVC solvent cement and the cost of
cutting chases and making good the same including testing of
joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the
DSR/18.8.1 15 mm nominal outer dia Pipes Metre 497.8 -
DSR/18.8.2 20 mm nominal outer dia Pipes Metre 260 537.6 1,39,776.00
DSR/18.8.3 25 mm nominal outer dia Pipes Metre 425 627.25 2,66,581.25
DSR/18.8.4 32 mm nominal outer dia Pipes Metre 739.3 -
3 DSR/18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply including all
CPVC plain & brass threaded fittings This includes jointing of
pipes & fittings with one step CPVC solvent cement, trenching,
refilling & testing of joints complete as per direction of Engineer
Pipe running at terrace level
DSR/18.9.6 50 mm nominal inner dia Pipes Metre 50 794.25 39,712.50
DSR/18.9.7 65 mm nominal inner dia Pipes Metre 1674.4 -
Digitally signed Page 4 of 5
Amount as per Amount as
S.No. DSR -2023 / NS Description Unit Qty. Rate (Rs.)
DSR (Rs.) per MR (Rs.)
DSR /18.9.8 80 mm nominal inner dia Pipes Metre 2166.35 -
DSR /18.9.9 100 mm nominal inner dia Pipes Metre 3271.7 -
DSR /18.9.10 150 mm nominal inner dia Pipes Metre 6822.7 -
4 MR Providing and fixing forged brass operated ball valve of full flow
of superior quality having minimum working pressure of 16
4.1 25 mm nominal bore Each 16 3262.00 52,192.00
4.2 50 mm nominal bore Each 2 9015.00 18,030.00
Digitally signed Page 5 of 5
SUMMRY OF ESTIMATE OF INTERNAL ELECTRICAL WORKS & ELV SYSTEM OF SCHOOL BUILDING
(G+3)& ASSEMBLY HALL, KV, BARKATAHA, HAZARIBAGH
SLNO DESCRIPTION DSR AMOUNT
1 SCHEDULE ITEMS (DSR-2025)
i) TOTAL OF SUB-HEAD :1-WIRING 52,55,665.00
TOTAL OF SUB-HEAD :2 MCCB,MCB & DB'S 6,38,717.00
TOTAL OF SUB-HEAD :3 HOT DIP Galvanized CABLE TRAY 74,600.00
TOTAL OF SUB-HEAD :4 EARTHING SYSTEM 2,12,780.00
v) TOTAL OF SUB-HEAD :5 LIGHTNING CONDUCTOR 1,92,347.00
vi) TOTAL OF SUB-HEAD :6 LED LIGHT & FAN 12,51,799.00
vii) TOTAL OF SUB-HEAD :7 MV CABLE LAYING ,JOINTING & END
TERMINATION 20,124.00
viii) TOTAL OF SUB-HEAD :8 SOLAR PV POWER GENERATION 27,14,000.00
ix) TOTAL OF SUB-HEAD :9 LIFT 16,84,225.72
x) TOTAL OF SUB-HEAD :10 UNITERRUPTED POWER SUPPLY 5,05,748.00
xi) TOTAL OF SUB-HEAD :11 HIGH WALL SPLIT AC 4,35,390.00
xii) SUB-HEAD :12 LOW VOLTAGE SYSTEM SCHEDULE ITEMS 49,56,430.00
xiii) SUB-HEAD :13 PUBLIC ADDRESS SYSTEM SCHEDULE ITEMS 13,11,358.00
TOTAL OF SCHEDULE ITEMS (PART-A) (DSR-2025 (ELEC.& 1,92,53,183.72
2 NON SCHEDULE ITEMS NON SCHEULE AMOUNT
i) TOTAL OF NON SCHEDULE ITEMS (PART-B) 83,15,653.00
ii) TOTAL OF PUBLIC ADDRESS SYSTEM (PART-C) 1,38,263.00
TOTAL (NON SCHEDULED ITEMS) (PART-B & C) 84,53,916.00
GRAND TOTAL ( (SCHEDULED ITEMS DSR-2025) PART-A 2,77,07,099.72
GRAND TOTAL ( (SCHEDULED ITEMS DSR-2025) PART-A 2,77,07,099.72
+(NON-SCHEDULED ITEMS ) PART-B
Digitally signed by PRIYA
ESTIMATE FOR INTERNAL ELECTRICAL WORKS & ELV SYSTEM FOR SCHOOL BUILDING (G+3), & ASSEMBLY HALL, KV, BARKATAHA, HAZARIBAGH
Sl. Item Description AMOUNT (NON
No. Code. UNIT QTY RATE SCHEDULE
SCHEDULE ITEMS (DSR-2025) (PART-A)
SUBHEAD :1_WIRING
1 D.S.R Point Wiring in Medium Class PVC Conduit, with Modular type Switch: Wiring for
1.10 light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/ HFFR PVC
( Page insulated copper conductor single core cable in surface/recessed Medium Class PVC
No.-03) conduit, with modular type switch, modular plate, suitable size of GI box and earthing the
point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc as
2 D.S.R Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper Point 18 1,803.00 32,454.00
1.11 conductor single core cable in surface / recessed medium class PVC conduit, 2way modular
( Page switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR
No.-03) PVC insulated copper conductor single core cable etc. as required.
3 D.S.R Wiring for light/power plug with 2x4 Sq.mm FRLS/HFFR PVC insulated copper conductor Mtr. 1800 373.00 6,71,400.00
1.12 single core cable in surface/recessed Medium Class PVC conduit along with 1 No. 4 Sq.mm
( Page FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing etc. as
No.-03) required.
4 D.S.R Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of
1.14 FRLS/HFFR PVC insulated copper condcutor, single core cable in surface/ recessed Medium
( Page Class PVC conduit as required.
5 D.S.R Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed
1.18 copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC
( Page conduit as required
6 D.S.R Supplying and fixing of following sizes of medium class PVC conduit along with accessories
1.21 in surface/recess including cutting the wall and making good the same in case of recessed
( Page conduit as required.
7 D.S.R Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with
1.22 suitable size of phenolic laminated sheet cover in front
( Page including painting etc. as required.
8 D.S.R. Supplying and fixing following modular switch/ socket on the existing modular plate &
1.24 switch box including connections but excluding modular plate etc. as required.
1.24.4 3 pin 5/6A socket outlet Each 40 136.00 5,440
1.24.6 Telephone socket outlet Each 18 168.00 3,024
9 D.S.R. Supplying and fixing two module stepped type electronic fan regulator on the Each 282 402.00 1,13,364.00
1.25 existing modular plate switch box including connections but excluding modular plate etc. as
( Page required.
10 D.S.R. Supplying and fixing following size/ modules, GI box along with modular base & cover plate
1.27 for modular switches in recess etc. as required.
11 D.S.R. Supplying and fixing suitable size GI box with modular plate and cover in front on surface Each 10 545.00 5,450.00
1.31 or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A
( Page modular switch, connections etc. as required.
12 D.S.R. Supplying and fixing suitable size GI box with modular plate and cover in front on surface Each 116 659.00 76,444.00
1.32 or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and
( Page 15/16 A modular switch, connections etc. as required.
13 D.S.R. Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block Each 300 104.00 31,200.00
1.33 including connections etc. as required
14 D.S.R. Supplying and fixing brass batten/ angle holder including connection etc. as required. Each 85 154.00 13,090.00
15 D.S.R. Installation, Testing and Commissioning of exhaust fan in the existing opening, including
1.50 making good the damage, connection, testing, commissioning etc. as required.
16 D.S.R. Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (
1.55 without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper
( Page conductor single core cable in surface/ recessed PVC conduit, and earthing the point with
No.-11) 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
17 D.S.R. Supplying and fixing suitable size GI box with modular plate and cover in front on surface Each 210 757.00 1,58,970.00
1.56 or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2
( Page nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non
No.-11) residential buildings).
18 D.S.R. Supplying & fixing suitable size GI box with modular plate and cover in front on surface or Each 10 807.00 8,070.00
1.57 in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP
( Page MCB, "C" curve including connections, painting etc. as required.
TOTAL OF SUB-HEAD :1 52,55,665.00
SUBHEAD :2 MCCB,MCB & DB'S
19 D.S.R. Providing and fixing following rating and breaking capacity and pole MCCB with
1.57 thermomagnetic release and terminal spreaders in existing cubicle panel board including
( Page drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage
No.-11) 690V etc. as required.
20 D.S.R 2.3 SPN DB:- Supplying and fixing following way, single pole and neutral, sheet steel, MCB
( Page distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral
No.-14) bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as
required. (But without MCB/RCCB/Isolator)
2.3.4 16 way, Double door Each 2 3,367.00 6,734.00
21 D.S.R 2.4 TPN DB :- Supplying and fixing following way, horizontal type three pole and neutral,
( Page sheet steel, MCB distribution board, 415 V, on surface/recess,complete with tinned copper
No.-14) bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including
earthing etc. as required. (But without MCB/RCCB/Isolator).
22 D.S.R 2.4 VTPN DB:- Supplying and fixing of following ways surface/ recess mounting, vertical type,
( Page 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted,
No.-14) inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for
mounting MCBs (but without MCBs and incomer ) as required .
(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
23 D.S.R MCB:- Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature
2.10 circuit breaker suitable for inductive load of following poles in the existing MCB DB
( Page complete with connections, testing and commissioning etc. as required.
2.10.3 Double pole Each 2 696.00 1,392.00
2.10.5 Triple pole and neutral Each 18 1,301.00 23,418.00
24 D.S.R Supplying and fixing following rating, double pole, single phase and neutral), 240 V,
2.14 residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing
( Page MCB DB complete with connections, testing and commissioning etc. as required.
25 D.S.R Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at
2.21 least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single
( Page red colour on front side as required.
TOTAL OF SUB-HEAD :2 6,38,717.00
SUBHEAD :3 HOT DIP Galvanized CABLE TRAY
26 D.S.R Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray
4.6 (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%,
( Page in convenient sections, joined with connectors, suspended from the ceiling with two
No.-26) numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts,fastener etc as
4.6.2 150 mm width x 50 mm depth x 1.6 mm thickness Mtr. 40 803.00 32,120.00
4.6.4 300 mm width x 50 mm depth x 1.6 mm thickness Mtr. 40 1,062.00 42,480.00
TOTAL OF SUB-HEAD :3 74,600.00
SUBHEAD :4 EARTHING SYSTEM
27 D.S.R. Earthing with G.I. earth plate 600 mm X 600 mm X6 mm thick including accessories, and
5.4 ( Page providing masonry enclosure with cover plate having locking arrangement and watering
No.-30) pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
i) LT Panel for School Building:- 2 nos
ii) 9 nos. VTPN DB (2 nos. in each Floor) + 1 no. for UPS) = 2x4+2= 10 nos.
ii) 1 no. Lift - 2 nos.
Total G.I.Plate Earthing - 14 nos. Each 14 8,351.00 1,16,914.00
28 D.S.R. Earthing with copper earth plate 600 mm X 600 mm X3 mm thick including accessories,
5.6 and providing masonry enclosure with cover plate having locking arrangement and
( Page watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
i) For Ups- 2 nos.
ii) Rack- 1 no.
ii) EPBEAX Machine-1 no.
29 D.S.R. Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip Mtr 20 1024.00 20,480.00
5.8 earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as
( Page required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring
No.-31) washer spaced at 50mm)
30 D.S.R. Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth Mtr 70 160.00 11,200.00
5.9 electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as
( Page required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring
No.-31) washer spaced at 50mm)
31 D.S.R. Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing Mtr 30 139.00 4,170.00
5.19 along with existing surface/recessed conduit /sub main wiring /cable as required.
TOTAL OF SUB-HEAD :4 2,12,780.00
SUBHEAD :5 LIGHTNING CONDUCTOR
32 D.S.R. Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. Each 11 609.00 6,699.00
6.1 tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including
( Page holes etc. complete as required.
33 D.S.R. Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for Each 350 148.00 51,800.00
6.6 lightning conductor complete as required.(For horizontal run)
34 D.S.R. Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for Each 165 238.00 39,270.00
6.7 lightning conductor complete as required.(For vertical run)
35 D.S.R. Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, Each 11 140.00 1,540.00
6.10 with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required
36 D.S.R. Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and Each 11 7,658.00 84,238.00
5.2 ( Page providing masonry enclosure with cover plate having locking arrangement and watering
No.-30) pipe etc. with charcoal/ coke and salt as required.
37 D.S.R. Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth Mtr 55 160.00 8,800.00
5.9 electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as
( Page required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring
No.-31) washer spaced at 50mm)
TOTAL OF SUB-HEAD :5 1,92,347.00
SUB-HEAD :6 LED LIGHT & FAN
Note:- All LED Light fittings LM 79 and LM 80 reports need to be submitted with all
accessories and 50,000.00 hrs shall as burning life. Samples of alltype LED light fixtures
are to be submitted to the Engineering Incharge and each LED Light should have minimum
100lm/W for the approval prior to procurement of light fixtures. Make Havels, Bajaj/
Signify-Philips/Wipro.
38 D.S.R. LED Down lighter (COB Type) (System lumen efficacy ≥105 < 120 lm/Watt ).
Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter
(Round/ Square/ Rectangular) COB Type of following body material and construction as
per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating
voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C,
internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%
, P.F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should
be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning
Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K
/4000°K/5700°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)
<3, Maximum power consumption should not more than the specified rating and
Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name
Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external
connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core
cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen
efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required
for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved
by Engineer-in-Charge as per requirement. (Thermal management: heat sink of
aluminium housing such that LED junction temperature shall not rise above 90°C) Powder
coated die cast /Extruded aluminium Body including trim with Aluminium Reflector .
39 D.S.R. LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).
8.9 Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of
( Page following body material and construction as per IS : 10322 with driver (Replaceable) as per
No.-45) the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt,
frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5
KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker
free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of
minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT
3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard DeviationColour
Matching) <3, Maximum power consumption should not more than the specified rating and
Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/
Embossing/ Screen printing on housing. complete in all respect i/c external connections
with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing
etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120
lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per
BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-
Charge as per requirement. (Thermal management: heat sink of aluminium housing such
that LED junction temperature shall not rise above 90°C). Powder coated die cast
/Extruded aluminium Body (Thickness > 1.20 mm)
D.S.R. 18- 22 Watt
D.S.R. 40 Watt
40 D.S.R. LED Street light fixture, powder coated pressure die cast aluminium body (System lumen
8.12 efficacy ≥105 <120 lm/Watt) (to use as building outer light)
Supplying, installation, Testing & Commissioning of Street light (to be use as Building
Outer Light) LED fixture powder coated pressure die cast aluminium body with driver as
per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC,
frequency 50/60 hz, Operating temp range -5°C to 50°C, internal surge protection of 5 KV
L,N,E as per IEC 61000-4-5,61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage
and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per
IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit
in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000
Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation
IES TM-21-11 report,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM
(Standard Deviation Colour Matching) <5, Maximum power consumption should not more
than the specified rating and Fixture shall be of relevant BIS standard complete in all
respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper
conductor single core cable and earthing etc. as required with Minimum 5 year OEM
warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and
all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall
be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat
8.12.12 sinkWofLED
LIGHT such that LED junction temperature shall not rise above 90°C). Each 8 1,782.00 14,256.00
41 D.S.R. Brush Less Direct Current (BLDC) Fan without Remote:-
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct
Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium
alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper
winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum
as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less
than 10%, suitable for operation with regulator
for speed control and all remaining accessories including safety pin, nut bolts, washers,
temperature rise=75 0C (max.), insulation resistance more than 2
mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS
374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR,
9.2.3 PVC insulated
1200mm, copper
service conductor
value single core cable
≥ 6.0 CM/Min/Watt, and earthing
air delivery etc. as(Minimum)
210 CM/Min required. Each 282 2,695.00 7,59,990.00
TOTAL OF SUB-HEAD :6 12,51,799.00
SUB-HEAD :7 MV CABLE LAYING ,JOINTING & END TERMINATION
42 D.S.R. Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of
10.7 1.1 KV grade of following size on wall surface as required.
i) 10.7.1 Upto 35 sq. mm (clamped with 1mm thick saddle) Mtr 90 64.00 5,760.00
ii) 10.7.2 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) Mtr 40 151.00 6,040.00
43 DSR Supplying and making end termination with brass compression gland and aluminium lugs
11.1 for following size of PVC insulated and PVC sheathed / XLPE aluminium
TOTAL OF SUB-HEAD :7 20,124.00
SUB-HEAD :8 SOLAR PV POWER GENERATION
44 DSR Solar Photovoltaic Power Plant :- Supplying Installation, Testing and Commissioning
17.1 of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS,
( Page IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD
No.-91- Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells
93) module, net metering facility, necessary control, protections, earthing, cabling, mounting
structure, junction boxes, power conditioning units, Real time online web interfaced Data
Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes,
cable trays and other accessories etc. as required.
a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above,
manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC
61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at
STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in
solar power plants/ systems must be warranted for their output peak watt capacity, which
should not be less
than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be
designed to operate in relative humidity upto 100% with temperature between -10 0C and
+85 0C. Further, each PV module used in any solar power project must have Radio
frequency identification tag with information such as name of manufacturer, month and
year of manufacturing, country of origin (separately for Solar cell and module), I-V curve,
Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab
issuing IEC certificate.
b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three
phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of
10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion
less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for
outdoor and Minimum IP 21 for indoor, Built-in
meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller
Microprocessor /DSP. PCU/inverter shall be capable of complete automatic
operation including wake-up, synchronization & shutdown. The PCU shall be able to
withstand unbalanced load conforming to IEC standard with shutdown/standby mode. It
must be provided with grid islanding along with manual disconnect pole isolation switch
besides automatic disconnection. Minimum protections: Mains Under / Over Voltage, Over
current, Over/Under grid frequency, Over temperature, Surge voltage induced at output
due to external source,
Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections as per
applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC
current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous &
cumulative AC output power, Daily DC energy produced and other parameters applicable
standard. Communication interface RS 485 / RS 232
c) Module mounting structure: The roof top solar plant generation units shall be installed
by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as
per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level /
ground level. The mounting structure would be designed to sustain wind load and seismic
parameter of the site of installation. All the structure shall be
design as per applicable BIS code and the material shall also confirm the applicable BIS
Code. Structural material shall be corrosion resistant and electrolytically compatible with
the materials used in the module frame, its fasteners, nuts and bolts. The suitable
arrangements for maintenance and cleaning shall be provided.
d) Real time online web interfaced Data Monitoring System complete with accessories for
various parameters such as Solar Irradiance, temperature, AC
Output Voltage and current, Output Power, Power factor, DC Input Voltage and Current,
Time Active, Time disabled, Time Idle, Power produced and other
parameters as per standard practices.
e) Array junction box & Main junction box with IP 65 protection and termination
arrangement for incoming and outgoing cable along with glands, lugs and other accessories
etc. as required. Each junction box shall be made of GRP/FRP/Powder Coated Aluminium
/cast aluminium alloy with full dust, water & vermin proof arrangement with High quality
Suitable capacity Metal Oxide Varistors(MOVs) (semiconductor diode with resistant applied
voltage)/ surge arrestors and suitable Reverse Blocking Diodes, isolation switches isolate
the DC input to Inverter, copper bus bar etc.
f) Lightning, surge voltage protection, earthing protection and grid islanding.
g) Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated
copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with
supplying & fixing of necessary channel/conduit, GI cable trays, supports, lugs, thimble
and other accessories etc. as required.
h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal kWp 50 54,280.00 27,14,000.00
cladded, having copper bus bar, having required protection and control gears, connection-
interconnection, etc. as required.
TOTAL OF SUB-HEAD :8 27,14,000.00
SUB-HEAD :9 LIFT
45 DSR 13 Passenger Lift :- Supplying, Installation, Testing & Commissioning of following
21.1 capacity passenger Machine room less (MRL) lift with regenerative drive as per CPWD
( Page General Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC
No.-109- 2016 as amended upto date having provision for barrier free access as per Harmonised
110) Guidelines & Standards for Universal Accessibility in India - 2021 of MoHUA, serving
different floors in the lift shaft as per detailed specifications enclosed and as under
including all other equipment and accessories complete as required:-
(i) Speed-1 MPS
(ii) Floors-5 (G+4)
(iii) Travel -17 Meters (approx.)
(iv) Stops & opening- 5 stops and 5 openings
(v) Controller: A.C. variable voltage & variable frequency
(vi) Automatic rescue device (ARD) complete with dry maintenance free batteries as
vii) Operation: Microprocessor based single automatic push button/simplex selective
collective/duplex collective selective with/without attendant
(viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system
(ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish)
on all sides and stainless steel decorative ceiling with fans (indirect
throw) and LED fitting.
(x) The car flooring should be smooth and antiskid as approved by engineer-in-charge.
(xi) Type of doors
(a) Car: Power operated, centre opening horizontal sliding stainless steel scratch proof
(Moon Rock/Honeycomb/ Hairline Finish).
(b) Landing doors: stainless steel scratch proof .
(xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent
to control panel in the lift car.
(xiii)Voice announcement system in the car to
announce the position of the elevator in the hoist way as the car passes or stops at floor
served by the elevator.
(xiv) Closed loop Control System, protection against power fluctuation, self diagnostic
control, Landing doors 2 hours Fire rated, Overload detection and
protection, Overspeed Governer, Dot Matrix LED D & P Indicators In Car & Landings, BMS
Compatibility, tamper proof infrared curtain covering almost the entire height of the lift car
door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera,
suitable NVR and HDD for 30 days storage
backup , Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup
for fan and light fitting for 1 hour, pit ladder.
(xv) The lift doors shall have a vision panel to enable
persons with hearing impairment to signal for help or assistance in the event of an
(xvi) An appropriate technological support be provided (Through emergency messaging
|services or alarms etc.) to respond to the emergency requirements of person with hearing
impairment or deafness.
(xvii) In case of failure of ARD or other electronic devices, a provision of manual rescue be
TOTAL OF SUB-HEAD :9 16,84,225.72
SUB-HEAD :10 UNITERRUPTED POWER SUPPLY ( UPS)
46 DSR Online UPS- Input supply: Three Phase, Output supply: Three Phase.
No.-190- Supplying, installation, Testing & Commissioning of following capacity at full load (Unity
Power Factor) at operating temperature 0 to 40 0C, Relative humidity 0 to 95%, Online
double conversion true sine wave Uninterrupted hot swapable (allow for the replacement
or addition of battery modules without shutting down the entire system) modular Power
Supply (UPS) system with N+1 modules (N denotes total number of modules required for
rated capacity). The UPS shall include a Rectifier, inverter, battery bank suitable for 30
minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS
rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container)
and Static Bypass switch along with for manual bypass, suitable isolation transformer for
additional protection against neutral faults etc. (As per correction Slip-1 DSR-568-H E &M-
2025- Chapter- 26) UPS shall have inbuilt phase sequence correction. The UPS systems
offered are to be of the latest technology with Digital Control Microprocessor based for
reliable operation using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier &
inverter (3 Level) with PWM (Pulse Width Modulation). The quality of design, manufacturing
and inspection process should confirm to the relevant Inter-national standards such as
IEC/EN/VDE. The operating efficiency of the UPS systems shall be >96% while operating
on battery mode and delivering quality power to the 100% non-linear loads.
Current total harmonic effect(ITHD) on the input grid shall be < 5% at 50 %load. (The
required LC ( inductor (L) and a capacitor (C)) filters shall be included in UPS cost),
extreme power factor kit to be included to limit the input power factor (PF) to 0.99 and
output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ),
however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads.
UPS shall be suitable for incoming supply AC : 3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC
Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins,
Sine wave output. Non condensing, noise level less than 60db at 1 meter distance,
protections: Input Under voltage over voltage, abnormal out voltage, battery over
charging, output over current, short circuit protection, battery deep discharge protection,
10KV surge. UPS must comply with low voltage electromagnetic compatibility (EMC)
achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency
Independent (VFI)-type UPS.
Communication RS232/RS485/SNMP port open protocol for BMS integration, all hardware &
software for iOT Communication as per approved by Engineering in charge. Required
battery racks and interconnecting copper conductor cables of suitable size and connectors
and all required accessories are inclusive of the cost). This system must provide a means
for logging and alarming of all monitored points plus email notification. Forced air-cooling
with integral inbuilt fans with redundancy (if one fan fail UPS should be able to handle at
least 80% of the load, Noise Level 65 DB at 1 meter distance. The system shall be in
compliance IEC 62040- 1,2 & 3, IS: 16242 and CPWD Specification. Display Panel
(minimum) (In-build 5 inch or more LC Display / LED) to display:-
a) Input: Voltage, current, Frequency.
b) Bypass: Voltage, Frequency
c) Output: Voltage, frequency, Current.
d) Battery: 191DELHI SCHEDULE OF RATES (E&M)-2025 Voltage, Capacity
e) Load: KVA, KW, Percentage
f) Temperature: STS, Inverter, PFC.
g) Event Logging & Statistical Data (On LCD/LED): UPS should capture and display up to
3000 events like:Over temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-
circuit / Device Fail / InverterFail / Rectifier Fail / Bypass Fail, etc.
h) Statistical Data: No. of power failures /Transfers to Bypass /Total Running time, etc.
i) Mains Mode of Operation/Battery Mode of Operation /Bypass feeding the load/UPS Fault
/Battery charging and discharging, overload, battery voltage and battery capacity.
j)Audible Alarms : Mains Failure,Battery Low Alarm, UPS Overload, Fault, Shutdown, Input
Over, Under Voltage, Output Over, Under Voltage,Battery Over,Under Voltage, Over Load
and short circuit, Over Temperature. The UPS should have QR code which should contain
drawing, test report OEM manual, Geo- Tag of manufacturing location etc. (Make:-
Numeric, Eton, Vertive, APC-Scnider)
26.2.3 30 KVA (Each Power module shall be < 10 KVA) Set 1 5,05,748.00 5,05,748.00
TOTAL OF SUB-HEAD :10 5,05,748.00
SUBHEAD :11 HIGH WALL SPLIT AC
47 DSR Supplying , Installation, Testing and Commissioning of Air
32.2 Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit
( Page (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell
No.-242- elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power
243) cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant,
wireless Remote control, suitable for working between 180- 260V with low & high voltage
cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air
circulation of following capacity with Scroll / rotary compressor. The system shall be able to
deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer
(OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical
cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical
Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329,
capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391
Part II 2023. The system shall be able to operate up to 50 0C (out door ambient
temperature). Inverter Type - Cooling only
32.2.3 1.5 TR with 5 Star BEE Rating set 10 43,539.00 4,35,390.00
TOTAL OF SUB-HEAD :11 4,35,390.00
SUB-HEAD :12 LOW VOLTAGE SYSTEM SCHEDULE ITEMS
TELEPHONE SOLUTION
47 D.S.R. Supplying, Installation, Testing & Commissioning of Analog phones having standard Each 18 1,544.00 27,792.00
38.4 feautres like 16 digit LCD display, 2 way speaker, caller ID and number storage facility etc.
( Page complete as required.
48 D.S.R. Supplying and drawing 20 Pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, Mtr 80 344.00 27,520.00
38.5 unarmored telephone cable in the existing surface/ recessed steel/ PVC Conduit etc.
( Page complete as required.
DATA NETWORKING SYSTEM
49 D.S.R. Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2
39.3 indoor Network Switch having features and specifications etc. as mentioned here under: At
( Page least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports
No.-269) with non-blocking architecture by having Switching capacity of min. 128 Gbps (As per
correction Slip-1 DSR-568-H E &M- 2025) and packet forwarding rate of 95Mpps (As per
correction Slip-1 DSR-568-H E &M- 2025) or higher, 16K MAC table. Console Port, USB
port, Stacking support of min. 4 units (As per correction Slip-1 DSR-568-H E &M- 2025)
per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction,
Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD
Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3,
UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN,
VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+
Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p.
ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP
V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying
Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge
protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications:
FCC, CE marked, UL/EN, RoHS and relevant MTCTE{TEC)/BIS compliance/
39.3.1 certification as applicable,
24 port PoE Layer etc. complete
2 Network Switch with PoE as required.
Support of 370W or higher with each copper Each 12 1,25,393.00 15,04,716.00
port supporting 802.3at PoE+ min.
50 D.S.R.- Supplying, installation, Testing and commissioning of following capacity 24 port Layer 3 Each 1 1,93,791.00 1,93,791.00
39.4 (P. Network Switch having features and specifications etc. as mentioned
no-.270) here under: At least 20 X RJ-45 Gigabit Ethernet Ports and additional 4 combo
DSR-2025 10/100/1000 base-t/SFP Ports with additional 4 SFP+ ports non-blocking architecture by
having Switching capacity of min. 128Gbps and packet forwarding rate of 95Mpps or
higher, 16K MAC table. Console Port, USB port, Internal AC Power supply with operating
temperature of 0 to +50 0C. Stacking port with stacking support of minimum 8 units per
stack. 48K Mac address, 9K or more Jumbo frame, ERPS with enabling ring to converge in
less than 50 ms from node or link failure, Static routing, Static, 6to4, ISATAP and GRE,
IPv6 Neighbor Discovery (ND), BGP, ISIS, MPLS, VRRP v2, OSPFv2/v3, PBR, Route
Redistribution, RIPv1/v2/ng, IP Helper all L3 Protocols should support from day 1 for both
IPv6 and IPv4, 802.1x, Port security , Radius CTACACS+ authentication C accounting,
DAD, DAI, DoS attack prevention, SSH, Guest VLAN, IP Access List, MAC Access List.
Multicast: VLAN, PIM-SM, PIMDM, PIM- SDM, PIM-SMv6, DVMRP v3 and MSDP, IGMP C
MLD Snooping, Flow mirroring, IGMP C MLD Snooping Ǫuerier, Per-VLAN IGMP C MLD
Snooping. SNMP, Dual configurations, Multiple images, RMON, LLDP/LLDP-MED, sFlow,
DHCP/BOOTP Client, IPv4/IPv6, Syslog server, Debug command, 802.3ah Ethernet Link
OAM, 802.1ag Connectivity Fault, Y.1731 OAM, 802.1Ǫbb Priority- based Flow Control
(PFC), Dying Gasp, Cable Diagnostics , 6 kV surge protection on all Gigabit Ethernet ports
and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product
must be on Trusted Telecom Portal of Department of Telecommunication,Government of
India etc. complete as required.
51 D.S.R. Supplying, Installation, Testing and commissioning of small form-Pluggable (SFP) for
39.6 Network Switches. Must be hot Pluggable, RoHS Complaint, etc. complete as required.
39.6.1 1G SFP Single Mode/Multi Mode Each 13 4,211.00 54,743.00
52 D.S.R. Supplying, Installation, Testing and commissioning of indoor Wireless Access Point for High Each 8 35,559.00 2,84,472.00
39.8 density use having features and specifications etc. as mentioned here under- WiFi6
( Page 802.11ax 574Mbps (2.4GHz) + 2402Mbps (5GHz), WIFI 6 Certified/WI-FI Alliance, MG
No.-273) 2.5G LAN POE Port, having console mangement function (As per correction Slip-1 DSR-
568-H E &M- 2025) factory reset, WPA/WPA2/WPA3™ Personal/Enterprise, WEP 64/128-
bit, SSID broadcast disable, MAC address access control, Internal RADIUS Customizable
Captive Portal, Auto Channel, Works as Access Point, WDS, with AP, Wireless
Client/Mesh,Web (HTTP), Secure Socket Layer (SSL), Traffic control, Support ATF/Fast
Roaming/Band Steering, Supports enhanced security – WPA-PSK/WPA2- PSK/WPA3-PSK
and RADIUS client, and Cipher negotiation, and MAC/ IP ACL for networks, Certifications:
FCC, CE,. marked, UL/EN, RoHS and relenant MTCTE ( TEC)/ BIS Compliance/
certification as applicable (As per correction Slip-1 DSR-568-H E &M- 2025) Works as
Standalone, Compatible with S/W & H/W Controller with addtional features like - Real-Time
Monitoring and Alerts, Rich Advanced Features, Centralized Device Management, Role-
Based Administration, Real-Time Monitoring, VLAN and Access Control, Auto RF
Management and Bandwidth Optimization, Multi-SSID and Captive Portal
Authentication.OEM/Product must be on Trusted Telecom Portal of Department of
Telecommunication, Government of India etc. complete as required
53 D.S.R. Supplying, Installation, Testing and commissioning of indoor Wireless Controller having Each 1 1,13,228.00 1,13,228.00
39.10 features and specifications etc. as mentioned here under- The network controller shall be a
( Page dedicated hardware appliance designed for centralized management of wireless access
No.-274) points, It must support the
management of up to 500 networking devices, The system should be on-premise, ensuring
data privacy and complete control over network configurations. It must include an intuitive
user interface for real-time
monitoring, device discovery, firmware upgrades, scheduling, and mass configuration
deployment. Features such as role-based administration, multi-sitemanagement. AP to
controller communication shall be use of industry standards-based (IEEE or IETF) CAPWAP
or any tunneling protocols as per guidelines of DoT.The controller should support Layer 2
and Layer 3 device discovery, VLAN configuration, MAC ACL groups, IGMP snooping, and
bandwidth optimization. Automatic radio frequency (RF) management and access policy
enforcement are required for reliable wireless performance. The solution must offer a
comprehensive dashboard with network topology, floor plan views, client and device lists,
and alert notifications. For authentication, it should support a range of methods including
database, external RADIUS, LDAP, and passcode or MAC-based access.
It should provide detailed traffic analytics, logs, and customizable reporting for network
visibility and planning. Firmware and configuration backup and
restoration functions must be available, with USBbased log storage supported. Physical
specifications should include a compact form factor with a minimum of one 2.5G Ethernet
port and USB 3.0 port, and it must be MTCTE,CE, FCC, and RoHS certified. The controller
should operate reliably within a 0°C to 40°C temperature range and 10–90% non-
humidity. /Product must be on Trusted Telecom Portal of Department of
Telecommunication, Government of India etc. complete as required.
54 D.S.R. Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must Each 13 5,278.00 68,614.00
39.11 be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch
(Page No.- Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-
274) 568.2-D etc. complete as required.
55 D.S.R. Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should
39.12 have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc.
(Page No.- complete as required.
39.13.1 Copper Patch Cords of length 1m (3ft) Each 255 173.00 44,115.00
39.13.2 Copper Patch Cords of length 3 m (10ft) Each 154 405.00 62,370.00
56 D.S.R. Supplying, Installation, Testing and commissioning of CAT6A Copper Information Outlet Each 164 302.00 49,528.00
39.15 (IO) with face plate of color as per site requirement, should have ETL/UL verification
( Page program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and
No.-275) Components should be from same OEM to maintain compatibility and interoperability etc.
complete as required.
57 D.S.R. Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. Each 164 9.00 1,476.00
39.16 RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-
(Page No.- 2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required.
58 D.S.R. Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper
39.18 cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable
(Page No.- suitable for high speed data networking application supporting upto 10Gbps over a 100
275) meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for
easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1,
Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC
11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter
should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc.
complete as required.
59 D.S.R. Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring.
39.19 The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following
(Page No.- Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-
277) core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE-
Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage
Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db / km) at Operational
Wavelength 1310 nm and ± 0.22 db / km at Operational Wavelength 1550 nm. type of
fiber should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675. The value for
Mode-filed, Cladding Diameter 9.2 ± 0.4 μm and 125 ± 0.7 μm correspondingly. The
Dispersion value < 3.5 < 18 ps/nm-km and PMD value < 0.2 ps/km and Cable Cutoff
wavelength < 1260 nm i/c splicing & marking etc complete as required.
39.19.1 6 Core Multi Mode Optical Fiber Cable Meter 125 64.00 8,000.00
60 D.S.R. Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable
39.21 saddles for jumper management, suitable to manage both splices and terminations, Pre-
(Page No.- assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal
278) splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber
storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter,
Removable front and rear covers for better access to interior of LIU, Should be Single /
Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws,
and spiral wrap tube etc complete as required.
61 D.S.R. Supplying and fixing Patch Cord of Optical Fiber Multi Mode or Single Mode LC to LC Fiber Each 5 705.00 3,525.00
39.22 Duplex having high precision ceramic ferrule with good concentricity, Fiber corning single
(Page No.- mode G652D, Cable Type 2mm with Mechanical specification Apex Offset < 50 μm, Fiber
278) Height + 100 nm, End-face radius of Curvature 7mm < R <25mm, Repeatability < 0.2 dB,
(As per correction Slip-1 DSR-568-H E &M- 2025) Working ambient Temperature – 5 0C
to +50 0C, Storage Temperature – 10 0C to +50 0C, Length -- 2meter, Type -- LC-LC
Duplex etc complete as required.
62 D.S.R. Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm
39.23 CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6
(Page No.- mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber
278) protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color-
RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3
numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc.
complete as required.
39.23.1 6U Rack (to use as equipment Rack for PA System) Each 4 6,939.00 27,756.00
63 D.S.R. Supplying and fixing 42U Rack with 6 inch Castor wheels and front brake Floor Standing Each 1 32,954.00 32,954.00
39.25 Rack with Main Frame Pillar of 1.6mm CRCA Sheet with removable side panels, L- Shape
(Page No.- adjustable Vertical Mounting Rail of 2mm with 'U'Marking completely knocked-down
278-279) condition (CKD) Shape, fitted with 4 number cooling fans, minimum 8nos two line cable
entry/exit provision at top and bottom with rubber protection, Front door 5mm Toughened
Glass with MS frame or MS perforated with lock, Rear MS vented or perforated door,
Powder coated Color- RAL- 7035 or black, complied with UL & RoHS, 2 x 6 sockets 16A
power distribution units, 3 numbers closed cable organizer, Hardware mounting screws
packet of 20 x 1 number, etc. complete as required.
63 5MP/6MP IP IR DOME CAMERA
D.S.R. Supplying Installation Testing and Commissioning of 5/6MP IP IR Dome Camera having
40.5 followingspecifications and features etc :-
( Page 1)Type of Camera: Dome Camera
No.-286) 2) Image Sensor: 1/2.8" or better progressive Scan CMOS get color image even at night
3) Signal System: PAL/NTSC
4) Minimum Illumination: 0.008Lux@ F1.4, AGC ON, 0 lux with IR or better
5) Imaging: 1/3s to 1/30000s Shutter Support, Auto Gain Control , White Balance- Auto,
Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.
6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded
7) Signal to Noise Ratio: > 50 dB
8) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto
switch, IR Source- Inbuilt IR LED's with effective distance upto 50 Mtrs integrated IR 30
Mtrs for colour view in night.
9) Video Compression (Minimum): H.265 or better, Audio:- G.711U/A, G.711Mu, G.726,
10) Wide Dynamic Range: WDR (120dB or more)
11) Digital Noise Reduction: DNR (2D/3D) On/Off
12) Streaming: Triple streaming, configurable
13) Video Streaming & Frame Rates: Triple streaming configurable Main stream: 5/6MP
@25/30 fps, Sub streams: D1@25/30 fps or better
14) Image Setting: Rotate Mode, saturation,
brightness, contrast, sharpness adjustable through client software or web browser
15) Profile Management: User configuration import, export
16) Security: User Authentication, Water Marking
17) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto
512 GB. It should be supplied with minimum 128GB memory Card.
18) Recording Management: Format SD, overwrite, storage management, video to NAS
device,19) Edge Analytics : Tripwire, Intrusion, Motion Detection
20) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP
conflict detection; memory card state detection; memory space detection
21) Alarm Support: It should have 1/1 Alarm In/ Out Port
22) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external
Mic. and Speaker (As per site requirement) with G.711U/A/ G.711Mu/ AAC/ G.726 audio
23) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP,
PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,
40.5.1 5MP/6MP IP IR 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement) Dome Camera. Each 86 12,800.00 11,00,800.00
5MP/6MP IP IR BULLET CAMERA
64 D.S.R. Supplying Installation Testing and Commissioning of 5MP/6 MP IP IR Bullet Camera having
40.6 following specifications, type of lens and features etc :-
(Page No.- 1) Type of Camera: Bullet Camera
288) 2) Image Sensor: 1/2.8" or better progressive Scan CMOS get color image even at night
3) Signal System: PAL/NTSC
4) Minimum Illumination: 0.006Lux@ F1.4, AGC ON, 0 lux with IR or better
5) Imaging: 1/3s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light
Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.
6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded
7) Signal to Noise Ratio: > 50 dB
8) Lens Type & Focus: as given below.
9) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto
switch, IR Source- Inbuilt IR LED's with effective distance upto 50 Mtrs integrated IR and
30 Mtrs for colour view in night.
10) Video Compression (Minimum): H.265 or better, Audio:- G.711U/A, G.711Mu, G.726,
11) Wide Dynamic Range: WDR (120dB or more)
12) Digital Noise Reduction: DNR (2D/3D) On/Off
13) Streaming: Triple streaming, configurable
14) Video Streaming & Frame Rates: Triple streaming , configurable Main stream:
5MP/6MP @25/30 fps, Sub streams: D1@25/30 fps or better
15) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable
through client software or web browser
16) Profile Management: User configuration import, export
17) Security: User Authentication, Digital Water Marking
18) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto
512 GB. It should be supplied with minimum 128GB memory Card.
19) Recording Management: Format SD, overwrite, storage management, video to NAS
Edge Analytics: Tripwire, Intrusion, Motion Detection
21) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP
conflict detection; memory card state detection; memory space detection
22) Alarm Support: It should have 1/1 Alarm In/ Out Port
23) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external
Mic. and Speaker (As per site requirement) with G.711U/A / G.711Mu/
AAC/ G.726 audio compreesion
40.6.1 5MP/6MP IP IR 2.8 to 3.6/6/8/12 mm fixed lens (as per site requirement outdoor Bullet Each 5 12,525.00 62,625.00
65 D.S.R. Supplying Installation Testing and Commissioning of following Channel Network Video
40.11 Recorder (NVR) with camera licenses to record for all channels having specifications and
(Page No.- features etc as mentioned below :
301) 1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses to
record per NVR and to provide a live view, storage and simultaneously
Multi-channel playback of all IP camera or more and must be ONVIF with minimum support
of 384 Mbps incoming Bandwidth.
2) NVR should support video compressions : H.265 or better, H.264, MJPEG.
3) Must support 1 channel RCA Input, 2 channel RCA Output for Two-way Talk with
G.711U/A, G.711u, PCM, G726 audio compressions.
4) Intelligent auto power on when power resumes after power outage.
5) Storage: It should support minimum 8 SATA Slots with 16TB capacity (As per
correction Slip-1 DSR-568-H E &M- 2025)/ Slot and RAID support of RAID 0/1/5/6/10.( 4
SATA ( 32 Channel) & 8 SATA Slot for 64 Channel).(As per correction Slip-1 DSR-568-
6) Connectivity Interface : 2 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x
RS232, 1x eSATA Port
7) Backup Interface : Its should have 4 Nosx USB port (2x USB3.0, 2xUSB2.0)
8) Video Output Ports: 2x HDMI and 2 VGA
9) Alarm Ports: It should have 16/8 Ch In/ Out ports to connect various type of external
sensors and output devices like hooter/ Siren etc.
10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated
mobile number for power failure, HDD failure, vandalism, tempring, network disconnection
11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for
alerts and viewing.
12) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6, UDP, DHCP, DNS, SMTP, UPnP, IP Filter,
PPPoE, FTP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T,
Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP
13) Standards: CE, FCC, RoHS, BIS Certified
14) Power Supply : Should support AC100-240V, 50/60Hz Power supply.
15) Operating Condition : -5°C to 50°C, humidity 90% (max) (non-condensing)
16) The VMS application shall support all the features & functionalities of the offered
17) VMS should consist Licenses for all channels to record Cameras with General, motion
detection, intelligent, alarm and POS recording modes. VMS should be provided with
Camera Licenses , with no\ dependency of VMS licenses by binding with the MAC
40.11.2 64 Channel Network Video Recorder (NVR) having display split :- Main screen: Each 2 82,600.00 1,65,200.00
66 D.S.R. Supplying, Installation, Testing and Commissioning following capacity Serveillance grade
40.12 Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch
( Page form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM,
No.-304) UKCA, VCCI, CB-Scheme, TUV, UL Certifications.
67 D.S.R. Access Control System with Face recognition
Supplying, Installation, Testing and Commissioning of Access Control System comprising of
Face and fingerprint Recognition, Smart Card, QR Code, NFC &
PIN Code based Reader, following sizes of 5” IPS TFT Touch Screens, 1GB RAM, 8 GB ROM,
Live Face Detection with anti-spoofing against 2D photograph,
mobile selfie & video, Fake Fingerprint and face Detection Technology, 30,000 Face storage
(1:N) /, 3,000 fingerprint (1:N), QR code 30,000, 30,000 card
storage (1:N), 2 lakh transaction storage, 20,000 image logs, onboard dual camera (colour
& IR) Primary camera min 2MP, Support Face authentication & verification from up to 1
meters, Communication protocols WiFi, TCP/IP, Wiegand
Out, Wiegand IN, USB, MQTT protocol, Blacklist Employee Management, User wise
authentication modes; Built in Lock Control, Mask Detection & Alert (configurable),
40 to 30,000 lux illumination, IP65 for Ingress Protection, Certification: CE, FCC, BIS,
ROHS, etc. Metal Enclosure with battery backup, suitable for mounting on metal
surface/metal frames/ wooden frames/wall/flap barriers including all mounting bracket &
accessories complete etc. as required
41.1.1 5" IPS TFT Touch Screen Each 2 58,306.00 1,16,612.00
67 D.S.R. LED Display
Supplying, Installation, Testing and Commissioning of following size LED display (LED
monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth
and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or
better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing
angle (H/V): 170°/ 170°, response time less than 12ms, Display control shall be on
monitor screen and programmable with remote (remote shall be supplied with system),
Key Board, Optical Mouse, etc. as required.
42.4.3 55 inch or larger (LED DISPLAY) Each 2 82,057.00 1,64,114.00
TOTAL OF LOW VOLTAGE SYSTEM SUB-HEAD :12 49,56,430.00
SUB-HEAD :13 PUBLIC ADDRESS SYSTEM SCHEDULE ITEMS
A) D.S.R. PUBLIC ADDRESS SYSTEM
68 28.3.1 Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, 1 1,32,115.00 1,32,115.00
MP4 player (including 6 zone button paging station) with seamless integration facility with Each
main fire alarm panel for voice evacuation complete as required.
69 28.3.3 Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall 63 1,891.00 1,19,133.00
speakers complete as required Each
70 28.3.7 Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms 5 1,52,368.00 7,61,840.00
operating at 240 Volt AC Supply complete as required. Each
71 28.3.8 Supplying, installation, testing & commissioning of exit point directional sound speaker with 5 10,618.00 53,090.00
voice and integral audio amplifier with selectable sound pulse patterns complete as Each
72 28.3.9 Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with 1 85,450.00 85,450.00
microphone assembly complete as required. Each
B) D.S.R. CABLING & WIRING
73 28.5.3 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the
existing surface / recessed steel conduit of following pairs, cores and size including
connections and interconnections etc. as required.
74 28.5.3.1 speaker cable Single pair, 2-core, 1.5 sqmm 2400 61.00 1,46,400.00
75 D.S.R. Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm
39.23 CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6
(Page No.- mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber
278) protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color-
RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3
numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc.
complete as required.
39.23.3 15U Rack (To use as Equipment Rack PA SYSTEM- FOR ASSEMBLY HALL ) Each 1 13,330.00 13,330.00
TOTAL OF PUBLIC ADDRESS SYSTEM SUBHEAD :13 13,11,358.00
TOTAL OF SCHEDULE ITEMS (PART-A) (DSR-2025 (ELEC.& ELV) 1,92,53,183.72
NON SCHEDULE ITEMS (PART-B)
SUBHEAD :13 (ELECTRICAL & ELV)
LED LIGHT FIXTURES
68 N.S. Note:- All LED Light fittings LM 79 and LM 80 reports need to be submitted with all
accessories and 50,000.00 hrs shall as burning life. Samples of alltype LED light fixtures
are to be submitted to the Engineering In charge and each LED Light should have
100lm/W for the approval prior to procurement of light fixtures.
(N.S.-i) Supply of 9W/10W LED Bulb (Luminous Flux- 600lm, CCT-6500K (Cool W 9/10 watt LED Each 85 104.00 8,840.00
Bulb, B22, 6500 Khite), CRI-80, Rated Voltage- 220V/ 240V. Beam Angle- 120 degree
(N.S.-ii) Supply and fixing of 10 W LED Type Bulk Head luminaire (Metal Body) with minimum Each 10 2,375.00 23,750.00
efficency 100lm/w in comprising of pressure die cast housing, acrylic diffuser, IP 66
protection and complete with ectronic driver etc. dirctly on wall or ceiling including
connection with 1.5 Sq. mm, FRLS PVC cu conductor cable etc. as required with lamp
(N.S.iii) Supply, installation, testing and commissioning of 2ft 10W LED Batten delivering an initial Each 62 621.00 38,502.00
system lumen of 1000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W.
The housing should be made of Extruded Aluminium with polycarbonate diffuser. The
operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered
electronic driver with input voltage range of 150 to 270V , PF ≥ 0.9 ,THD ≤ 10%, 50,000
Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have
minimum surge protection of 2.5KV. The luminaire shall be with following certifications:
LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard.
(N.S.iv) Supply, installation, testing & commissioning of 5W LED Foot/Step Light 4000K light, Each 20 1,053.00 21,060.00
Having minimum IP-65 and Efficacy minimum 100 Lm/W, LM6 high pressure die cast
aluminium housing, Glass/Acralic cover surface mounting , clip and surface as required
with complete accessories.
(N.S.v) Supply, installation, testing & commissioning of Environmental friendly, energy saving long Each 16 9,286.00 1,48,576.00
life, vertical surface mounting pressure 50W Warm White in Circular shape Ceiling
suspended decorative LED corrision resistant dia cast alluminium housing ( Light engine )
well glass luminaires with high power LED as light source. 4000K light as required with
complete accessories.
69 N.S. All Exhaust shall be of minimum 2 years of Warranty. Samples of all Fans are to be
submitted to the Engineer-in- charge for the approval prior to procurement of Exhaust
(i) Supply of 230mm 230V AC single phase,1440RPM Exhaust Fan, double ball bearing (Metal Each 9 2,002.00 18,018.00
Body, metalick blade,- Light Duty) exhaust fan as required.
ii) Supply of 300mm 230V AC single phase,1440RPM Exhaust Fan, double ball bearing (Metal Each 20 2,364.00 47,280.00
Body, metalick blade,- Light Duty) exhaust fan as required.
70 N.S. LT CABLE 1.1 KV
Supply of following size of 1.1KV (A2XFY) XLPE / PVC Insulated / PVC sheathed (Heavy
Duty) armoured electric cable with aluminium conductor as ) Extruded PVC Type ST2 Outer
Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date
Amendments.Make:- Polycab, Havells, Ultra Tech, KEI, Gloster , AltraVolt.)
a)) SITC of 3.5 Core 25 Sq. mm. XLPE PVC Al. / Ar. Cable 1.1 KV Mtr. 100 497.00 49,700.00
b) SITC of 3.5 Core 50 Sq. mm. XLPE PVC Al. / Ar. Cable 1.1 KV Mtr. 50 856.00 42,800.00
68 N.S. 80L WATER PURIFICATION COOLER
SITC OF 80L Water Purification Cooler (80 Liter | 40 L/Hr) Cooling Capacity & 80L Storage |
Cold Water | Stainless Steel
a)Colour- Stainless Steel
b) Capacity- 80 litres
c) Brand- BLUE STAR,Voltas, Havells
d) Product Dimensions - 8.5D x 66.5W x 114H Centimeters
e)Installation Type- Plumbed
DETAIL SPECIFICATION OF
a)High-Efficiency Cooling System: Delivers 40 litres per hour cooling with an 80-litre
storage tank, ensuring uninterrupted cold water supply for 100–120 users, ideal for
schools, offices, and commercial settings.
b) Dual Tap Dispensing: Features 2 cold water taps to enable simultaneous usage, reducing
wait time during high-demand periods and enhancing user convenience.
c) Optimized Cooling Technology: Powered by R134a refrigerant and a 2.5 Amp system, it
offers energy-efficient cooling while maintaining consistent water temperature throughout
d) SS Body: The stainless steel rust resistant body ensures long-lasting performance, while
the food grade tank delivers pure, contaminant free water. The extra large stainless steel
water tray effectively prevents water splashing and ensures rapid drainage.
e) Multiple Features: A sturdy compressor which guarantees durability and reliability. With
its fast cooling technology, this machine rapidly cools water. It is an environment friendly
machine. This machine is equipped with an openable lid with a locking mechanism for
cleaning and safety purposes.
f) Installation Charges as per Actuals (Whether you buy offline or online, Brand applies
installation charges as per actuals on site) or as per actuals
g) 1-YEAR WARRANTY + 5-YEAR COOLING COIL WARRANTY: Comes with a 1-year
comprehensive warranty and an extended 5-year warranty on the cooling coil for added
Cost of 80L WATER PURIFICATION COOLER Each 8 52,980.00 4,23,840.00
69 N.S. INTERACTIVE TOCH PANEL 75"with inbuilt AI Camera and noise cancelling mic.
SITC OF 75" Intractive Touch Panel with inbuilt AI Camera and noise cancelling mic.
Interactive Flat Panel Digital Board with Stand, 8 GB RAM 128 GB ROM, Ai-Copilot,
Multitouch Screen Display for Teaching & Office Use
A) Brand BIG VUE,Hickvision, LG, Samgung.
B) Colour PRO C)Material
Recommended Uses For Product Office, School E)
Mounting Type Wall Mount
75 Inch 4K AI Interactive Flat Panel with Android 14, 48MP AI Camera, 8-Mic Array, 20-
Point Multi-Touch, 4K UHD Display, Wireless Screen Sharing, Smart Whiteboard & Video
Conferencing etc.
Detail Specification of 75" Intractive Touch Panel with inbuilt AI Camera and
noise cancelling mic.
i) 75" Ultra HD 4K AI Display – Premium IPS display with 3840 × 2160 UHD resolution, anti-
glare toughened glass and 178° viewing angle delivers stunning visuals for classrooms,
conference rooms and training centers.
ii)48MP AI Camera with 8-Mic Array – Built-in 48MP AI Auto-Tracking Camera and 8-array
AI Noise Cancellation Microphones provide professional-quality video conferencing with
automatic speaker tracking and crystal-clear voice pickup
iii) Android 14 Smart Collaboration – Latest Android 14 operating system with AI
Whiteboard, annotation tools, wireless screen sharing, browser, file manager and
productivity applications for interactive learning and business meetings.
iv)20-Point Ultra Fine Multi-Touch – High-precision infrared touch technology enables
multiple users to write, draw and collaborate simultaneously using fingers or stylus pens
with ultra-low response time.
v)Accessories: Power Cord, Remote, USB-C cable, USB A-B cable, HDMI cable, Stylus Pen
vi)Rich Connectivity & Powerful Audio – Dual Band Wi-Fi, Bluetooth, HDMI, USB Type-C,
USB, LAN, OPS Slot and dual 20W stereo speakers ensure seamless connectivity and
immersive audio performance.
vii)Three years on Site Warranty.
ix) Touch Technology: IR, Touch Points: 60, Pen Tip Size: 2.8mm/8mm, Port Connection:
USB Type B x 4, Compatible OS: Windows 8.1/10/11; Chrome OS; MacOS 10.15/11/12
x)This product comes with the Android operating system and includes an OPS slot. The
OPS slot allows the device to function as a dual processing unit and enables memory
expansion. Please note that the OPS module is not included with the system
xi) The above 75" Interactive Touch Panel with inbuilt AI Camera and noise cancelling mic -
4K UHD Display with resolution 3840x2160 pixels. Anti-glare, Anti-Smudge and anti-
blocking design, Inbuilt Dual-OS - in build AI Camera , Windows & Android, D-LED
Backlight, 1.07 billion colour depth, 400 cd/m2 brightness, 4000:1 Contrast Ratio, 60Hz
refresh rate, 178-deg Viewing Angle, 6.5ms response time, 4GB RAM, 32GB Internal
Memory, Android-11 inbuilt OS, 20-point multi touch, Built-in OPS Slot, Input Slots: HDMI
In × 1, LINE In × 1, VGA In × 1, AV In × 1, Type-C × 1, Output Slots: HDMI OUT × 1,
Audio Line Out(3.5 mm jack) × 1, SPDIF OUT × 1, Transmission Inteface: USB 3.0 × 3,
USB 2.0 × 1, TYPEC x 1(11 W), LAN/RJ45 × 1, TOUCH-USB × 1, RS232 × 1. Built-in
2x16Watt Speaker.
Cost of INTERACTIVE TOCH PANEL 75" ) Interactive Touch Panel with inbuilt AI Camera SET 38 1,71,732.00 65,25,816.00
and noise cancelling mic -
N.S.I Supply, fitting fixing and testing of 63A/ FP. 10kA, C Series MCB .(Make:-MCB-LEGRAND- Each 8 2,738.00 21,904.00
DX³/SCHNEIDER- ACTI-9/SIEMENS- BETA GUARD/ L&K- AU VERSION.)
71 N.S. LT PANEL FOR SCHOOL BUILDING (G+3)
Supplying, designing, manufacturing and commissioning in correct alignment position,
effecting proper connection of all incomer and outgoing feeders of LT Panel , unloading at
site, shifting to loaction, fitting, fixing and testing of meter Panel, fabricated out of 2 mm
thick (14SWG) CRCA sheet steel for Load bearing and 1.6 mm or 16 SWG Unload Bearing,
dust and vermin proof with reinforcement of suitable size iron channel, size 75 mm x 40
mm x 6 mm, (or ISMB CHANNEL) with proper lifting arrangement, (IP-42) fully
compartmentalized cubical type (folded joints construction), Floor Mounted, totally
enclosed, accessories, all out going feeders protection & meters as required, factory built
sheet steel enclosed extendable panel and suitable for use on 415V, 3 phase, AC Supply, 4
wire, 50 C/S, system having 25 KA fault capacity, housed with incoming and outgoing
aluminum bus bars, interconnection, interlocking between feeders etc. with indicating
lamps, push buttons, necessary accessories, all out going feeders protection & meters as
The sheet steel under go minimum 7 tanks treatment followed by finishing of powder
coating of minimum 60 micron thickness, duly compartmentalized having accessories
mounted inside the cubical panel, earthing with 2 Nos. earth studs.
The LT Panel shall be totally enclosed, completely dust and vermin proof. Synthetic rubber
gaskets (neoprene/DPDM) between all adjacent units and beneath all covers shall be
provided to render the joints dust proof. All doors and covers shall be fully gasketed and
shall be lockable. Doors shall have concealed hinges. All the doors shall be suitably
reinforced by channel to provide rigidity. Panel shall have suitable cable entry from
bottom/Top and suitable arrangement for aluminum cable termination.
The LT Panel shall be provided with a thermostatically controlled heating arrangement (200
W) to take care of high humidity conditions. A 6/16A socket with sitch as service outlet
(single phase) and 1 no. 10W LED LAMP with holder shall be provided in one of the
compartments as service outlet in the panel. The complete panel shall be fuse less type,
for control circuits 2A SP MCB's to be used.
For the protection of equipment & feeders, switchgear shall be provided with required O/C
& S/C releases. Selection of switchgear rating shall be made on the basis of load current &
fault withstand capacity.
Panel Builder will provide shop drawing SLD & GA drawing along with BOM with CAT. No. of
each and every components and switch gears of Meter Panel for approval of Consultant or
concirned department. Inspection of the Meter Panel shall be carried out at Panel Builder's
factory by the Consultantor departmental engineers before final delivery for that all
arrangements shall be made by the contractor.
Location :- IN SUB STATION BUILDING
The Name Plate for each feeder must be in Anodized Aluminium Sheet.
The Panel Builder must be CPRI approved. Panel builder must produce test certificate for
Type Tested & Short Ckt withstand capacity as per IEC-60439-II from CPRI.
MCCB:- L&K-DSine/ LEGRAND-DPX³/SCHNEIDER-NSX/ SIMENS- 3VJ-3WJ
MCB- C Series 10kA _ Legrand- DX³/Schneider- ACTI-9/Siemens- Beta Guard/ L&K- AU
Panel Size - As per Drawing and shall be provided at the time of work order.
1 Set of Fabrication part of LT Panel & busbar system, with AL. bus bar and
interconnection FRLS cables) in 14 SWG (2 mm Thick) CRCA Sheet Steel enclosure (IP-42)
without components. Name of Panel builders:- EAP Kolkata, Green Galaxy Kolkata, A.C.
Popwer Kolkata, JMD, Kokar, Ranchi, Meditiron, SIRDO, BIT Meshra, Ranchi. Amichand
Technology, Jamshedpur.
1 Sets Multifunction Meter having LED mete display accuracy Class 1 as per IEC 62053-21,
should have an active RS-485 port, in built RTC, Aux Supply: 44-277Vac/dc. Parameters:
Volts, Amps, PF, THD, F, W, Wh, VA, VAh, Var, Varh, Runhrs, Onhrs Interrupts, THD for
V&I per phase, individual harmonics for V&I upto 15th level complying with IEC61557-12.
Min/Max for eight parameters. Sampling rate: 64 samples per cycle.
3 Nos. CT of different power as per incomer & out going /5VA -5 class one Epoxy resin cast
CT (3 Nos.)=1 Set.
3 Sets Phase indicating light shall be protected by 2 Amps SP MCB's for incomer &
1 no. 400A/FP/MCCB (36kA) with adjustable Thermomagnetc Release , with S/C, O/L
protection, alkong with ON OFF TRIP indication and with extended front rotary handle and
spreader links in Both End. (Cable Size :-1 Run 3.5 C 240 SQ MM AL. AR. Cable.)
OUT GOING FEEDERS WITHOUT DG
5 nos. 100/P MCCB (25kA) with adjustable thermomagnetc release type with S/C & O/L
protection, and front rotary Handle and spreader links in both end. (For Power All Floor
VTPN DB and 1 no. as spare.(Cable Size :- 1 Run 3.5 C 50 SQ MM AL. AR. Cable.)
1 no. 63/P MCCB (25kA) with adjustable thermomagnetc release type with S/C & O/L
protection, and front rotary Handle and spreader links in both end. (1 no. as spare (Cable
Size :- 1 Run 3.5 C 35 SQ MM AL. AR. Cable.)
1 no. 25/P MCCB (25kA) with adjustable thermomagnetc release type with S/C & O/L
protection, and front rotary Handle and spreader links in both end as future use.
FEEDERS WITH DG SUPPORT
Provision of Mechnical interlocking between 200A/FP/25KA MCCB as common incoming for
essential load and 1 No. of 200A on load TPN Change over as D.G incomer, in such a way
so that the two supplies are not parallel at any time.
1 no. 200A/FP/MCCB (25kA) with adjustable Thermomagnetc release , with S/C, O/L
protection, alomg with extended front rotary handle and spreader links in both ends.
1 No. 200A TPN on load Manual ON Load Change over panel mounted open execution type
and suitable bus arrangement for Cable termination. (Cable Size :- 1 Run 3.5 C 120 SQ MM
AL. AR. Cable.) Make-L&K/Sucomo/ Legrand.
10 nos. 63/P MCCB (25kA) with adjustable thermomagnetc release type with S/C & O/L
protection, and front rotary Handle and spreader links in both end. (4 nos. for Light VTPN
DB, 2 nos. for Lift Machines (1 working and one future use), 1 No. for UPS, 1 no. for fire
fighting, , 1 no. for Roof Top Solar Panel Feeder,and 1 no. as spare (Cable Size :- 1 Run
3.5 C 25 SQ MM AL. AR. Cable.)
2 nos. 25/P MCCB (25kA) with adjustable thermomagnetc release type with S/C & O/L
protection, and front rotary Handle and spreader links in both end. 1 no. for Pump Panel
and 1 no. as spare
3 no. 32A DP MCB C Series of 10 kA
Total Cost of LT Panel. Set 1 8,07,039.00 8,07,039.00
72 N.S. EPABX SYSTEM
EPABX SYSTEM along Server Software and Unified Communication Server
Software and Hot StandBy Server Software System-Epabx
Supply, fitting, fixing, commissioning and testing of IP based 100% non-blocking IP EPABX Set 1 1,32,808.00 1,32,808.00
System should be a IP Compatible with rich feature set of the system and can be
connected with pure Voice over IP (VoIP) communication network across corporate Local
and Wide Area Networks (LAN and WAN) as & when required.
• IP PBX SYSTEM along Server Software and Unified Communication Server Software and
Hot StandBy Server Software Pabx System-Epabx
• Central Processing Unit: The system main software should be open architecture based.
The CPU of main system shall be 32 bit processor working at 2.0 GHz or better. The
system should be Wall mountable.
• System Architecture should be latest pure IP and should be wall Mountable
• Meet-me conference 30 party X 2 from day 1 must be available.
• Must Support Unified Communications •
Equipped with 20 Analog extensions , 1 IP Extensions loaded from day expandable upto 2
IP Extensions, VOIP CARD in built charger, battery with one our back up facitity.
• 20 Analog Trunk Ports, 1 SIP Trunk , 01 Ports Auto Attendant- EPABX .
Make:- Avaya/Syntel by Arvind Telecom/Alacatel
TELEPHONE SOLUTION
73 N.S.I Krone box:-
Providing, fixing, connecting & testing of Krone box (Telephone Tag Block) in a
thermoplastic, IP 65 (weather proof) enclosure, internally embedded gasket, anti corrosive,
insulated and shock proof with provision for cable through IP 65 glands complete in all
respects. (Make : Matrix/Alcatel/Avaya.
i) 10 pair Tag Block (krone Box) (136 mm x 253 mm x 115 mm) Each 2 1,328.00 2,656.00
ii) 50 pair Tag Block (krone Box) (300 mm x 300 mm x 70 mm) Each 1 3,064.00 3,064.00
TOTAL OF NON SCHEDULE ITEM (PART-B) 83,15,653.00
74 N .S ( PUBLIC ADDRESS SYSTEM) PART-C
(N.S.-i) SITC of Handheld combo variable frequency, high quality, UHF band frequency dual Each 2 38,899.00 77,798.00
wireless Microphone System, 80 selectable UHF Channels. UHF Operating Frequency Range-
583-683 MHZ, back light display for frequency. Separate LCD display doe channels, high
quality capsul in handheld mic, XLR balanced and unbalaced out, flight case. (1 no for
Podium at Assdembly Hall & 1 no. in Principal room for announcement)
(N.S.-ii) WOODEN PODIUM FOR ASSEMBLY HALL
SITC of wooden podium / lectern made of high-quality engineered wood / commercial No 1 60,465.00 60,465.00
plywood with premium laminate finish, sturdy construction, sloping top writing surface,
concealed cable management and provision for keeping laptop/documents, complete with 1
No. flush-mounted connectivity dataplate comprising 1 No. HDMI female port, 1 No. VGA
(15-pin) female port, 1 No. 3.5 mm AUX audio input socket and 1 No. 5/6A, 230V AC
power socket with proper earthing. The podium shall include all necessary internal cabling,
connectors, mounting accessories and hardware as required
TOTAL OF NON SUBHEAD ITEM (PART-C) 1,38,263.00
TOTAL (NON SCHEDULED ITEMS) (PART-B & C) 84,53,916.00
GRAND TOTAL ( (SCHEDULED ITEMS DSR-2025) PART-A +(NON-SCHEDULED 2,77,07,099.72
GRAND TOTAL ( (SCHEDULED ITEMS DSR-2025) PART-A +(NON-SCHEDULED 2,77,07,099.72
PROJECT: PROPOSED KENDRIYA VIDYALAYA CAMPUS AT BARKATHA, DIST.- HAZARIBAGH, JHARKHAND
MAIN SCHOOL BUILDING (G+3)
DETAILED ESTIMATE OF FIRE FIGHTING AND FIRE DETECTION SYSTEM
DSR E&M- SOR Amount NON-SOR TOTAL Amount
DSR E&M- SOR Amount NON-SOR TOTAL Amount
S.No. Description Unit Qty. SOR Rate (Rs.) Market Rate
2025/ NS (Rs.) Amount (Rs.) (Rs.)
Internal Piping
1 DSR-25 Providing, laying, testing & commissioning of ’C’ class heavy
27.7 duty MS pipe conforming to IS 3589/IS 1239 including Welding,
fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc.
and fixing the pipe on the wall/ceiling with suitable
clamp/support frame and painting with two or more coats of
synthetic enamel paint of required shade complete as required :
2 DSR-25 (A) Supplying, installation, testing and commissioning of electric
27.4 driven terrace pump suitable for automatic operation and
consisting of following, complete in all respects, as required:
(B) Horizontal type, multistage, centrifugal, split casing pump of
cast iron body & bronze impeller with stainless steel shaft,
mechanical confirming to IS : 1520
(C) Suitable HP squirell cage induction motor TEFC type suitable
for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55
class of protection for enclosure, horiziontal foot mounted
type with Class-’F’ insulation, conforming to IS-325.
(D) M.S. fabricated common base plate, coupling, coupling
guard, foundation bolts etc. as required.
(E) Suitable cement concrete foundation duly plastered and with
anti vibration pads.
3 MR Fire pump control panel (DOL/Star-Delta Starter) for 7.5 HP, 900
LPM Fire pmp, Atomatic/Manal, IS:13947, NFPA 20, IEC 60947,
UL 508, Power supply 415 AC, 3-Phase, 50Hz.
4 DSR-25 Supplying, fixing, testing and commissioning of butterfly valve of
27.11 PN 1.6 rating with bronze/gunmetal seat duly ISI marked
complete with nuts, bolts, washers, gaskets conforming to IS
13095 of following sizes as required :
Supplying & Fixing of Gunmetal Bourdon Type pressure gauge
with gunmetal isolation ball valve tapping and connecting pipe
and nipple for pump sets, complete in all respects, as per
Technical Specifications and Drawings, suitable for working
pressure of 250 PSI. Cost shall be inclusive of providing any
short pieces, nipples, elbows etc as required.
Providing, installation, testing and commissioning of non-return
valve of following sizes confirming to IS: 5312 complete with
rubber gasket, GI bolts, nuts, washers etc.as required :
6 DSR-25 Supplying and fixing orifice plate made out of 6 mm thick ₹ 1,436.00 ₹ 28,720.00
27.13 stainless steel (Grade304) with orifice of required size to be
fitted between flange & landing valve of external and internal
hydrants to reduce pressure at the outlet to the level of 3.5
kg/cm2 complete as required. Set 20 ₹ 28,720.00
7 DSR-25 Providing, installation, testing and commissioning of stainless
27.15 steel Y-strainer fabricated out of 1.6 mm thick stainless steel,
Grade 304, sheet with 3 mm dia holes with stainless steel
8 DSR-25 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with
27.16 63 mm dia male and female couplings duly bound with GI wire,
rivets etc. conforming to IS 636 (type-A) as required :
9 DSR-25 Supplying & fixing 63 mm dia gun metal short branch pipe with
27.18 20mm nominal internal diameter size nozzle conforming to IS
903 suitable for instantaneous connection to interconnect hose
Internal Hydrant
Digitally signed by 1 of 2
DSR E&M- SOR Amount NON-SOR TOTAL Amount
DSR E&M- SOR Amount NON-SOR TOTAL Amount
S.No. Description Unit Qty. SOR Rate (Rs.) Market Rate
2025/ NS (Rs.) Amount (Rs.) (Rs.)
10 DSR-25 Supplying and fixing single headed internal hydrant valve with
27.9 instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia
with cast iron wheel ISI marked conforming to IS 5290
(Type -A) with blank Gunmetal/Stainless Steel cap and chain as
27.9.2 Single headed Stainless Steel Set 20 ₹ 6,632.00 ₹ 1,32,640.00 ₹ 1,32,640.00
11 MR Supplying & installation of approved 1.6mm thick M.S. fire hose
cabinet (750x600x250mm) made ot of 16 gauge M.S. sheet
capable of accomodating two sets of RRL hose pipes, fittings &
accessories. The box shall have a front glass door with lock and
key arrangement & shall be painted with post office red color
Sprinkler System
12 DSR-25 Providing, fixing, testing & commissioning of 15mm dia
27.21 quartzoid bulb type sprinklers of rating 68 degree centigrade
with required accessories :
Fire Detection and Alarm System
13 Supplying, installation, testing and commissioning of micro
processor based intelligent addressable main fire alarm panel,
central processing unit with the following loop modules and
capable of supporting not less than 240 devices (including
detectors) and minimum 120 detectors per loop and loop length
up to 2 km, network communication card, minimum 320
character graphics/ LCD display with touch screen or other
keypad and minimum 4000 events history log in the non volatile
DSR-25 memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48
28.2.1 hrs back-up with 24 volt sealed maintenance free batteries with
automatic charger.
The panel shall have facility to connect printer to printout log
and facility to have seamless integration with analog/digital
voice evacuation system (which is part of the schedule of work
under SH: PA System) and shall be complete with all accessories
. The panel shall be compatible for IBMS system with open
protocol BACnet/ Modbus over IP complete as per
specifications.
14 Supplying, installation, testing and commissioning of Smoke ₹ 92,948.00
detector and mounting base with LED light complete as
15 DSR-25 Supplying, installation, testing & commissioning of intelligent ₹ 66,888.00
28.2.6 addressable programmable sounder complete as required.
16 DSR-25 Supplying, installation, testing & commissioning of addressable ₹ 97,512.00
28.2.14 manual call point complete as required. Each 24 ₹ 4,063.00 ₹ 97,512.00
17 DSR-25 Supplying, installation, testing and commissioning of response ₹ 7,344.00
28.2.5 indicator on surface/recessed MS box having two LED , metallic
cover complete with all connections etc as required.
18 DSR-25 Supplying and laying of 2x1.5 sqmm fire survival armoured ₹ 5,21,100.00
28.5.1 cable, 600/1000V rated with annealed copper conductor having
glass mica fire barrier tape covered by an extruded layer of cross
linkable ethylene propylene rubber (EPR) insulation and LSZH
inner bedding, steel wire armouring & LSZH outer sheath
complete as required. metre 1350 ₹ 386.00 ₹ 5,21,100.00
Fire Extinguishers
19 MR Providing of ABC powder type( stored pressure) Fire
Extinguisher 4 KG. Capacity,ISI marked, IS 15683 for class 4 A
&89 B type of fire field with MAP -90 complete in all
20 MR Providing of CO2 type( stored pressure) Fire Extinguisher
4.5 KG. Capacity,ISI marked, IS 15222 with all accessories
complete in all respect.(Manual) Set 10 ₹ 4,500.00 ₹ 45,000.00 ₹ 45,000.00
21 MR Supplying & Fixing, Fire Buckets 9 litres capacity round bottom
sand buckets along with bucket stand (Wall hanging type) as
per local fire officer's standards and located at ground floor.
Emergency Lights
22 MR Supply, installation, testing and commissioning of LED
emergency light fitting, 6–10W, minimum 2 hours backup, with
lithium-ion/SMF battery, automatic operation on mains failure,
complete with driver, housing, wiring, mounting accessories,
and all necessary connections as per site requirement.
TOTAL FOR SOR-ITEMS ₹ 18,83,166.00
TOTAL FOR NON SOR-ITEMS ₹ 3,87,972.00
GRAND TOTAL ₹ 22,71,138.00
GRAND TOTAL ₹ 22,71,138.00
Digitally signed by 2 of 2
KV BARKATHA | SIGNAGE BOQ
Item Zone Item specification — supply and installation complete Size / extent Unit Quantity Rate (₹) Amount (₹)
Representative visual — concept only
S01 Outdoor Illuminated main school identity. Providing, fabricating, supplying
and fixing school entrance identity sign comprising 4 mm exterior
ACP fascia with 0.30 mm minimum aluminium skins on 40×40×2
mm MS box frame, zinc-rich primer and two coats exterior PU
paint, routed bilingual lettering and approved KVS emblem backed
with 3 mm opal acrylic, low-voltage LED modules, IP67 drivers in 3600 × 900 mm each 1 34,675.42 34,675.42
accessible enclosure, sealed joints, SS anchors, internal wiring and
testing; mounted to existing sound entrance wall, complete. No
new masonry included. Electrical supply point measured separately
S02 Outdoor Secondary gate identity. Providing and fixing non-illuminated gate
identification board of 3 mm exterior-grade aluminium composite
panel with aluminium skins minimum 0.25 mm, exterior printed
polymeric vinyl and UV-resistant matt overlaminate, sealed edges,
rounded corners, stainless steel screws and concealed fixings, on
25×25×1.6 mm painted MS frame including SS wall anchors, 1800 × 600 mm each 2 4,454.35 8,908.71
complete; existing wall mounting.
S03 Outdoor Campus orientation map. Providing and fixing campus map of 3
mm exterior-grade aluminium composite panel with aluminium
skins minimum 0.25 mm, exterior printed polymeric vinyl and UV-
resistant matt overlaminate, sealed edges, rounded corners,
stainless steel screws and concealed fixings, with YOU ARE
HERE, north arrow, pedestrian and accessible routes, approved 1200 × 900 mm each 1 5,482.28 5,482.28
building labels and legend, on 25×25×1.6 mm painted MS frame
including wall fixings, complete. Graphic preparation from
approved plan included.
S04 Outdoor Pedestrian direction sign on post. Providing and fixing single-face
directional board of 3 mm exterior-grade aluminium composite
panel with aluminium skins minimum 0.25 mm, exterior printed
polymeric vinyl and UV-resistant matt overlaminate, sealed edges,
rounded corners, stainless steel screws and concealed fixings,
fixed to one 60×60×3 mm painted MS post, board top about 2100 900 × 450 mm; one face each 6 6,852.85 41,117.10
mm above finished ground, with 250×250×10 mm base plate, four
M16 anchors, 450×450×600 mm M20 concrete footing over 75 mm
lean concrete, excavation, backfill and making good, complete.
Member sizes are budget basis; submit wind/stability design before
S05 Outdoor Parking and traffic control on post. Providing and fixing
traffic/parking board comprising 2 mm aluminium sheet with
engineering-grade retroreflective film, approved pictograms and
bilingual legend, 50×50×3 mm painted MS post, top about 2100
mm, 200×200×10 mm base plate, M12 anchors, 400×400×600 mm
M20 footing over 75 mm lean concrete, excavation and backfill 600 × 450 mm; one face each 8 4,111.71 32,893.68
complete; submit stability details.
S06 Outdoor Assembly point sign on post. Providing and fixing green assembly-
point board of 3 mm exterior-grade aluminium composite panel
with aluminium skins minimum 0.25 mm, exterior printed polymeric
vinyl and UV-resistant matt overlaminate, sealed edges, rounded
corners, stainless steel screws and concealed fixings, with
pictogram on 50×50×3 mm painted MS post, top about 2100 mm, 600 × 600 mm each 2 4,797.00 9,593.99
200×200×10 mm base plate, M12 anchors and 400×400×600 mm
M20 concrete footing over 75 mm lean concrete including
excavation and backfill, complete; coordinate safe location with fire
evacuation plan.
S07 Outdoor Sports area identity and rules. Providing and fixing wall/fence
mounted sports identity and concise safety-rules board of 3 mm
exterior-grade aluminium composite panel with aluminium skins
minimum 0.25 mm, exterior printed polymeric vinyl and UV-
resistant matt overlaminate, sealed edges, rounded corners,
stainless steel screws and concealed fixings, on 25×25×1.6 mm 900 × 600 mm each 7 3,769.07 26,383.47
painted MS frame, with SS clamps/anchors, complete.
S08 Outdoor Garden and activity area identity. Providing and fixing wall/low-
fence mounted area identity sign of 3 mm exterior-grade
aluminium composite panel with aluminium skins minimum 0.25
mm, exterior printed polymeric vinyl and UV-resistant matt
overlaminate, sealed edges, rounded corners, stainless steel
screws and concealed fixings, with concealed SS fixings or clamps 600 × 300 mm each 6 1,439.10 8,634.59
to existing support, complete.
S09 Outdoor Service and hazard board. Providing and fixing safety/service
identification sign of 3 mm exterior-grade aluminium composite
panel with aluminium skins minimum 0.25 mm, exterior printed
polymeric vinyl and UV-resistant matt overlaminate, sealed edges,
rounded corners, stainless steel screws and concealed fixings,
approved warning colours and pictograms, SS screws or fence 450 × 300 mm each 6 1,014.22 6,085.33
clamps, complete; wording and voltage on electrical signs
approved by electrical consultant.
Digitally signed by PRIYA
S10 Outdoor Residential block identity. Providing and fixing residential block
identity board of 3 mm exterior-grade aluminium composite panel
with aluminium skins minimum 0.25 mm, exterior printed polymeric
vinyl and UV-resistant matt overlaminate, sealed edges, rounded
corners, stainless steel screws and concealed fixings, wall
mounted with SS screws and plugs, complete. 600 × 300 mm each 3 1,439.10 4,317.30
S11 Outdoor Residence number plate. Providing and fixing individual dwelling
number plate of 3 mm exterior-grade aluminium composite panel
with aluminium skins minimum 0.25 mm, exterior printed polymeric
vinyl and UV-resistant matt overlaminate, sealed edges, rounded
corners, stainless steel screws and concealed fixings, bilingual
number/identifier, SS screws and plugs, complete. 200 × 100 mm each 9 479.70 4,317.30
S12 Indoor Classroom and Balvatika door plate. Providing and fixing
classroom identification plate of 3 mm solid aluminium panel,
powder-coated finish, UV-printed high-contrast Hindi and English
lettering with matt protective clear coating, rounded corners and
concealed screw fixings, including approved room number and
class label, complete. 300 × 150 mm each 38 712.70 27,082.46
S13 Indoor Specialist and administration door plate. Providing and fixing
specialist/administration room identification plate of 3 mm solid
aluminium panel, powder-coated finish, UV-printed high-contrast
Hindi and English lettering with matt protective clear coating,
rounded corners and concealed screw fixings, complete.
S14 Indoor Service-room identification. Providing and fixing service-room
identification sign of 3 mm solid aluminium panel, powder-coated
finish, UV-printed high-contrast Hindi and English lettering with
matt protective clear coating, rounded corners and concealed
screw fixings, with appropriate hazard pictogram where needed,
S15 Indoor Toilet identification with pictogram. Providing and fixing toilet
identification plate of 3 mm solid aluminium panel, powder-coated
finish, UV-printed high-contrast Hindi and English lettering with
matt protective clear coating, rounded corners and concealed
screw fixings, clear male/female/child pictogram with bilingual text,
complete; no cubicle-door plates included. 200 × 200 mm each 32 644.17 20,613.37
S16 Indoor Accessible tactile and Braille identity. Providing and fixing tactile
accessibility sign on 2 mm powder-coated aluminium base with
raised pictogram and characters, Grade 1 Braille in approved
language, non-glare high-contrast finish, rounded edges and
concealed screws, complete; locate adjacent to latch side at
accessible reach height subject to consultant approval. Includes 300 × 200 mm each 14 1,576.16 22,066.18
bilingual printed text; specialist Braille proof required.
S17 Indoor Main school directory. Providing and fixing main directory sign of 3
mm solid aluminium panel, powder-coated finish, UV-printed high-
contrast Hindi and English lettering with matt protective clear
coating, rounded corners and concealed screw fixings, in
25×25×1.6 mm painted MS backing frame, approved floorwise
room list, arrows and colour bands, complete. 900 × 1200 mm each 1 5,482.28 5,482.28
S18 Indoor Floor directory. Providing and fixing floorwise directory of 3 mm
solid aluminium panel, powder-coated finish, UV-printed high-
contrast Hindi and English lettering with matt protective clear
coating, rounded corners and concealed screw fixings, in
aluminium edge frame, with current floor marker, room list and
arrows, complete. 600 × 900 mm each 4 3,220.84 12,883.36
S19 Indoor Corridor directional panel. Providing and fixing single-face corridor
direction panel of 3 mm solid aluminium panel, powder-coated
finish, UV-printed high-contrast Hindi and English lettering with
matt protective clear coating, rounded corners and concealed
screw fixings, approved arrows and up to three destinations,
mounted flat to wall or beam without reducing headroom, 600 × 200 mm each 16 1,507.63 24,122.03
Digitally signed by PRIYA
S20 Indoor Stair and floor marker. Providing and fixing stair identification and
floor marker of 3 mm solid aluminium panel, powder-coated finish,
UV-printed high-contrast Hindi and English lettering with matt
protective clear coating, rounded corners and concealed screw
fixings, bilingual floor number and stair ID, complete.
S21 Indoor Drinking water identification. Providing and fixing drinking-water
sign of 3 mm solid aluminium panel, powder-coated finish, UV-
printed high-contrast Hindi and English lettering with matt
protective clear coating, rounded corners and concealed screw
fixings, including potable-water pictogram, complete.
S22 Indoor Lab and activity safety rules. Providing and fixing concise safety-
rule board of 3 mm solid aluminium panel, powder-coated finish,
UV-printed high-contrast Hindi and English lettering with matt
protective clear coating, rounded corners and concealed screw
fixings, with room-specific pictograms and bilingual instructions,
complete; text proofed by school/subject teacher. 450 × 600 mm each 8 1,850.27 14,802.16
S23 Indoor School conduct and safeguarding board. Providing and fixing
bilingual school conduct/information board of 3 mm solid
aluminium panel, powder-coated finish, UV-printed high-contrast
Hindi and English lettering with matt protective clear coating,
rounded corners and concealed screw fixings, max 150 words
equivalent including safety pictograms and approved school 600 × 900 mm each 4 3,015.25 12,061.02
contact fields, complete; excludes general display/notice boards.
S24 Indoor Evacuation plan board. Providing and fixing location-specific
evacuation plan printed on photoluminescent film bonded to 2 mm
aluminium sheet, matt finish, showing YOU ARE HERE, correct
orientation, escape route, stairs, fire equipment and assembly
point, including graphic preparation and SS fixings complete;
prepare from approved fire plan and validate every location. 450 × 600 mm each 8 2,192.91 17,543.30
S25 Indoor Photoluminescent exit-direction sign. Providing and fixing
photoluminescent escape-direction sign on 1.5 mm aluminium
backing with green/white running-man pictogram, arrow and
bilingual legend, complete with SS screws; submit glow
performance test certificate suitable for approved fire strategy.
These supplement electrically illuminated exit signs. 300 × 150 mm each 24 507.11 12,170.66
S26 Indoor Battery-backed LED exit sign. Supplying, installing, testing and
commissioning maintained LED EXIT sign, double-face display
where required, rigid aluminium housing with green/white
pictogram and bilingual legend, minimum 90-minute rechargeable
battery backup, automatic changeover, charge indicator, test
switch, wall/ceiling brackets and internal wiring complete; electrical 300 × 150 mm nominal each 16 2,261.44 36,183.05
supply point measured under S31. Confirm required autonomy with
fire consultant.
S27 Indoor Fire equipment identification. Providing and fixing
photoluminescent fire-equipment identification sign on 1.5 mm
aluminium backing with red/white pictogram and bilingual text,
complete with SS screws, coordinated to actual installed
equipment; equipment itself excluded.
S28 Indoor Fire action instruction board. Providing and fixing fire-action
instruction board on 1.5 mm aluminium backing with
photoluminescent printed face, pictograms, approved bilingual
instructions, alarm/office contact fields and SS fixings complete.
S29 Indoor Lift safety and restricted access. Providing and fixing
caution/restricted-access plate of 3 mm solid aluminium panel,
powder-coated finish, UV-printed high-contrast Hindi and English
lettering with matt protective clear coating, rounded corners and
concealed screw fixings, approved pictogram and bilingual text,
Digitally signed by PRIYA
S30 Indoor Glazed-door visibility manifestation. Providing and applying
durable opaque frosted/coloured safety manifestation film in two
continuous 50 mm wide bands on clear glass at architect-approved
visible heights, including cleaning, cutting, alignment and finishing
complete. Measured as actual running length of film per band;
glass and door signs excluded. 50 mm wide; two bands m 40 109.65 4,385.82
S31 Electrical Electrical supply point for illuminated signs. Providing and
connecting dedicated sign supply point from existing nearby
protected lighting circuit, with 2×1.5 sq.mm copper FRLS
conductors plus 1×1.5 sq.mm earth in 20 mm conduit for route up
to 10 m each, local isolating switch, weatherproof junction box
where outdoors, termination, earthing continuity, testing and One point; maximum 10 m
making good, complete; no new DB, long feeder, trench or meter route
included. Gate sign final circuit and protection to be checked by
electrical consultant.
TOTAL BUDGET 4,91,349.35
Digitally signed by PRIYA
PROPOSED CONSTRUCTION OF STAFF QUARTER TYPE-III (G+1)
ABSTRACT OF COST - CIVIL WORKS
SOR-2023 NON SOR
Sl. No. SOR-2022 DESCRIPTION
A 2 EARTH WORKS 2,49,750.65 -
B 4 CONCRETE WORKS 2,48,066.58 -
C 5 REINFORCED CEMENT CONCRETE WORK 51,34,899.81 -
D 6 BRICK WORK 12,44,991.32 -
E 8 MARBLE & GRANITE WORK 3,54,242.94 -
G 10 STEEL WORK 3,20,852.74 -
H 11 FLOORING WORK 7,78,277.33 -
J 13 FINISHING WORK 14,09,656.84 -
K 21 ALUMINIUM WORK 3,784.18 -
L 22 WATER PROOFING 1,45,156.24 -
GRAND TOTAL 1,13,83,668
GRAND TOTAL 1,13,83,668
Digitally signed by PRIYA
BILL OF QUANTITYFOR STAFF QUARTER TYPE-III (G+1)
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
A 2.00 EARTH WORKS
1 2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas
(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and
disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-
i 2.6.1 All kinds of soils Cum 271.38 177.50 48,169.42
2 2.7 Earth work in excavation by mechanical means (Hydralic excavator/manual means)over areas
(exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and
disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by Engineer - in
3 2.10 Excavating trenches of required width for pipes, cables, etc. including excavation for sockets,
and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated
soil, and then returning the soil as required, in layers not exc
a 2.10.1 All kinds of soil.
i 2.10.1.2 Pipes, cables, etc. exceeding 80mm dia but not exceeding 300mm dia. Metre 20.00 352.15 7,043.00
4 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in
layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and
watering, lead up to 50 m and lift upto 1.5 m.
5 2.26. Extra for every additional lift of 1.5 m or part thereof in excavation /
banking excavated or stacked materials.
5.2 2.26.2 Ordinary or hard rock Cum 6.00 227.40 1,364.40
6 2.27 Supplying and filling in plinth with sand under floors, including watering,
ramming, consolidating and dressing complete. Cum 28.57 2123.75 60,665.13
7 2.28 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15
cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
i 2.28.1 All kinds of soil Sqm 385.00 34.15 13,147.75
8 2.34 Supplying chemical emulsion in sealed containers including delivery as specified
i 2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% Litre 54.42 234.75 12,775.10
9 2.35 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment
(excluding the cost of chemical emulsion) :
i 2.35.1.1 Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm
of the vertical surface of the substructure to a depth of 300mm including excavation channel
along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1%
a) 2.35.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm
apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2
Coarse sand) to match the existing floor:
i 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration Sqm 145.12 310.05 44,994.46
TOTAL (Carried Over to Summary of Civil Works) 2,49,750.65 0.00
B 4.00 CONCRETE WORKS
1 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of
centering and shuttering - All work up to plinth level :
a 4.1.6 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone
aggregate 40 mm nominal size derived from natural sources) Cum 14.73 7178.75 1,05,760.22
b 4.1.8 1 :4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from
natural sources : 8 graded stone aggregate 40 mm nominal
size derived from natural sources) Cum 12.35 6812.00 84,127.35
2 4.3 Centering and shuttering including strutting, propping etc. and removal of form work for :
i 4.3.1 Foundations, footings, bases for columns. Sqm 15.36 392.15 6,023.42
3 4.11 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2
coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal
size derived from natural sources).
4 4.12 Extra for providing and mixing water proofing material in cement concrete work in doses by
weight of cement as per manufacturer's specification. Per 50 kg
5 4.13 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality
using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and
finally with a piece of cloth lightly soaked in kerosene oil. Sqm 22.22 146.15 3,247.64
Digitally signed by PRIYA
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
6 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone -
III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40
mm nominal size, well rammed and consolidated and grouted with fine sand, including
necessary excavation, levelling & dressing & finishing the top smooth.
TOTAL (Carried Over to Summary of Civil Works) 2,48,066.58 0.00
C 5.00 REINFORCED CEMENT CONCRETE WORK
1 5.9 Centering and shuttering including strutting, propping etc. and removal of form for :
a 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete. Sqm 136.48 392.15 53,520.63
b 5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
c 5.9.3 Suspended floors, roofs, landings, balconies and access platform. Sqm 383.95 927.25 3,56,015.32
d 5.9.4 Shelves (Cast in situ) Sqm 36.98 927.25 34,285.07
e 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers Sqm 481.39 736.40 3,54,492.94
f 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts. Sqm 207.06 961.30 1,99,046.78
g 5.9.7 Stairs, (excluding landings) except spiral-staircases. Sqm 42.71 764.95 32,667.19
i 5.9.16 Edges of slabs and breaks in floors and walls
j 5.9.19 Weather shade, Chajjas, corbels etc., including edges. Sqm 15.12 951.10 14,380.63
2 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position
and binding all complete upto plinth level.
i 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg 5923.70 107.85 6,38,871.05
3 5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position
and binding all complete above plinth level.
i 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg 15697.39 107.85 16,92,963.81
4 5.33.1 Providing and laying in position ready mixed or site batched design mix cement concrete for
reinforced cement concrete work; using coarse aggregate and fine aggregate derived from
natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in
recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve
durability and workability without impairing strength; including pumping of concrete to site of
laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and
reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be
payable separately. In case the cement content in design mix is more than 110% of the specified
minimum cement content, the contractor shall have discretion to either re-design the mix or bear
the cost of extra cement.
a) 5.33.1 All works upto plinth level.
i 5.33.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum Cum 55.07 9504.75 5,23,437.28
b) 5.33.2 All works above plinth level upto floor V level.
i 5.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum Cum 119.08 9860.40 11,74,130.70
5 5.30 Add for plaster drip course/ groove in plastered surface or moulding to
R.C.C. projections. metre 330.70 78.40 25,926.88
TOTAL (Carried Over to Summary of Civil Works) 51,34,899.81 0.00
D 6.00 BRICK WORK
1 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in
foundation and plinth in:
i 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 14.22 7132.25 1,01,436.64
2 6.32 Brick work with clay flyash F.P.S. (non modular) brick of class designation
7.5 in superstructure above plinth level up to floor five level in :
i 6.32.2 Cement mortar 1 :6 (1 cement : 6 coarse sand) Cum 100.37 9095.05 9,12,826.06
3 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks
of class designation 7.5 in superstructure above plinth level up to floor
3.1 6.13.2 Cement mortar 1 :4 (1 cement :4 coarse sand) Sqm 187.80 1123.80 2,11,047.39
4 6.15 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half
brick masonry. Sqm 187.80 104.80 19,681.23
TOTAL (Carried Over to Summary of Civil Works) 12,44,991.32 0.00
E 8.00 MARBLE & GRANITE WORK
1 8.2 Providing and fixing 18mm thick gang saw cut ( premoulded and prepolished) machine cut for
kitchen platforms, vanity counters, window sills , facias and similar locations of required size of
approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4
coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch
ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc.
complete at all levels.
b) 8.2.2 Granite of any colour and shade
Digitally signed by PRIYA
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
2 8.3.2 Providing edge moulding to 18 mm thick marble stone counters, Vanities
etc., including machine polishing to edge to give high gloss finish etc.
complete as per design approved by Engineer-in-Charge. (Granite work) metre 23.40 510.95 11,956.23
3 8.4 Extra for fixing marble /granite stone, over and above corresponding
basic item, in facia and drops of width upto 150 mm with epoxy resin
based adhesive, including cleaning etc. complete. metre 23.40 568.55 13,304.07
1 8.5 Extra for providing opening of required size & shape for wash basin/
kitchen sink in kitchen platform, vanity counter and similar location in
marble/ Granite/ stone work, including necessary holes for pillar taps etc.
including moulding, rubbing and polishing of cut edges etc. complete. Each 4.00 978.70 3,914.80
4 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be
specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle
green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and
dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with
grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of
matching shade complete.
TOTAL (Carried Over to Summary of Civil Works) 3,54,242.94 0.00
F 9.00 WOOD, WPC & uPVC WORK
1 9.21.1 Providing and fixing ISi marked flush door shutters conforming to IS :
2202 (Part I) non-decorative type, core of block board construction
with frame of 1st class hard wood and well matched commercial 3 ply
veneering with vertical grains or cross bands and face veneers on both
faces of shutters: (35 mm thick including ISi marked Stainless Steel butt hingesn with necessary
2 9.127.2 Providing & Fixing decorative high pressure laminated sheet of plain
I wood grain in gloss / matt/ suede finish with high density protective
surface layer and reverse side of adhesive bonding quality conforming to
IS : 2046 Type S, including cost of adhesive of approved quality. (1.0 mm thick) Sqm 58.22 897.30 52,240.81
3 9.23 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges
of flush door shutters (over all area of door shutter to be measured).
4 9.24.1 Extra for providing vision panel not exceeding 0.1 sqm in all type of
flush doors (cost of glass excluded) (overall area of door shutter to be
measured): Rectangular or square
5 9.26 Extra for cutting rebate in flush door shutters (Total area of the shutter to
be measured). Sqm 10.66 106.70 1,137.42
6 9.70.2 Providing and fixing IS : 12817 marked stainless steel butt hinges with
stainless steel screws etc. complete : 100X58X1.90 mm
7 26.86 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid
door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of
K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice
husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated
with miter joints after applying PVC solvent cement and screwed with full body threaded star
headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of
2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of
elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of
being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S
hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of
Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Note:
For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of
profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but
no extra payment on this account shall be made.
8 26.87 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain
flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension
Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic
additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum
and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive
strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class
A category with property of being termite/ borer proof, water/moisture proof and fire retardant
and fixing with stainless steel butt hinges of required size with necessary full body threaded star
headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless
steel butt hinges and necessary S.S screws shall be paid separately)
9 9.46.2 Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two
chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever
necessary complete : 20 mm dia Rmt 63.54 393.25 24,987.11
10 9.48.2 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats,
square or round bars etc. including priming coat with approved steel primer all complete.Fixed to
openings /wooden frames with rawl plugs screws etc. Kg 412.99 238.35 98,436.64
Digitally signed by PRIYA
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
11 9.96.2 Providing and fixing aluminium sliding door bolts, ISi marked anodised
(anodic coating not less than grade AC 10 as per IS : 1868), transparent
or dyed to required colour or shade, with nuts and screws etc. complete : (250x16 mm)
12 9.97 Providing and fixing aluminium tower bolts, ISi marked, anodised (anodic
coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed
to required colour or shade, with necessary screws etc. complete :
13 9.103 Providing and fixing bright finished brass 100 mm mortice latch and lock,
ISi marked, with six levers and a pair of anodised (anodic coating not less
than grade AC 10 as per IS : 1868) aluminium lever handles of approved
quality with necessary screws etc. complete. Each 4.00 868.95 3,475.80
14 9.82 Providing and fixing bright finished brass hanging type floor door stopper
with necessary screws, etc. complete. Each 38.00 121.65 4,622.70
15 9.165 Providing and fixing bright /matt finished Stainless Steel handles of
approved quality & make with necessary screws etc all complete.
16 9.84 Providing and fixing aluminium extruded section body tubular type
universal hydraulic door closer (having brand logo with ISi, IS : 3564,
embossed on the body, door weight upto 36 kg to 80 kg and door width
from 701 mm to 1000 mm), with double speed adjustment with necessary
accessories and screws etc. complete. Each 4.00 983.15 3,932.60
17 9.135 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory
windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of
dia. 0.50 mm all complete.
17.1 9.135.2 With 12 mm mild steel U beading Sqm 7.38 1228.00 9,062.64
18.00 9.147A Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead
free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded
profiles having minimum wall thickness of 1. 70 mm for Series R 1 and R2 profiles and 2.10 mm
for Series R3 and R4 profiles conforming to EN: 12608 in any shape,
colour and design duly reinforced with galvanized mild steel section
made of required shape & size as per CPWD Specification, uPVC extruded glazing beads,
interlocks and lnline sash adaptor (where ever required) of appropriate dimension, EPDM
gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head,
comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS
1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc.
Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically
jointed duly sealed at all corners, including drilling of holes for fixing
hardware and drainage of water etc. After fixing frame the gap between frame and adjacent
finished wall shall be filled with weather proof silicon sealant over backer rod of approved size
and quality, all complete as per approved drawing conforming to CPWD specification & direction
of Engineer-in-Charge. Section of steel reinforcement and cross sections
of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire
mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance
coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid
Note:- Structural design proof checked from a Government Engineering Institute, to be provided
by the manufacturer for
(i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3
(ii) Sites with structure height more than 20m for all wind speeds
18.1 9.14 7 .A 1 Two track two panels sliding window with Aluminium channel
for roller track, wool pile, nylon rollers with SS 304 body.
18.2 9.147.A1.1 Using R2 series with frame (40 mm & above)
x (40 mm & above) & sash (25 mm & above)
x (50 mm & above) with zinc alloy (zamak)
powder coated touch locks with hook (Height
18.3 9.147.A4 Three track three panels sliding window with two glazed
& one wire mesh panels with Aluminium channel for roller
track, wool pile, nylon rollers with SS 304 body.
18.4 9.147.A4.1 Using R2 series with frame (70 mm & above) x
(40 mm & above) & both glazed and fly screen
sash (25 mm & above) x (50 mm & above)
with zinc alloy (zamak) powder coated touch
locks with hook. (Height upto 1.2 metre). Sqm 14.76 10993.55 1,62,264.80
18.5 9.147.C1.1 Fixed window/ ventilator without mullion/ transom. Using R1 series with frame (33 mm & above)
x (35 mm & above). (Height upto 0.90 metre) Sqm 2.88 8247.25 23,752.08
Digitally signed by PRIYA
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
19.00 MR-1 Providing and installing SGG Evolite Clear (ET 150) Single Glazed Unit (SGU), comprising 6 mm
thick coated glass with coating on Face 2, having a light transmission of 50%, external light
reflection of 13%, internal light reflection of 11%, Solar Heat Gain Coefficient (SHGC) of 0.50
and U-value of 5.0 W/m²K as per EN 673, complete with all necessary glazing accessories,
compatible sealants, labour, handling, transportation and installation as per approved drawings
and manufacturer's specifications. Sqm 34.42 3095.46 1,06,533.45
20 9.131.1 Providing and fixing factory made shutters of Pre-laminated particle
board flat pressed three layer or graded wood particle board with one
side decorative finish and other side balancing lamination conforming
to IS: 12823 Grade I Type 11, of approved design, and edges sealed with
water resistant paint and lipped with aluminium 'U' type edge beading
all- round the shutter, including fixing with angle cleat, grip strip, cadmium
plated steel screws, including fixing of aluminium hinges 100x63x4 mm
etc. complete as per architectural drawing and direction of Engineer-inCharge
(Cost of 'U' beading and hinges will be paid for separately).
21 9.167 Providing and fixing 6 mm thick both sides Pre-laminated cement
bonded wood particle board as per IS : 15786:2008 of approved brand
and shade with suitable full threaded steel screws etc. on the backing of
racks, drawer, cupboard, kitchen cabinet under kitchen counter etc. all
complete as per direction of Engineer-in-charge.
22 9.170.1 Providing and fixing stainless steel fancy handle of approved make fixed
with SS screws etc. complete as per direction of Engineer-in-charge. (200mm)
TOTAL (Carried Over to Summary of Civil Works) 10,53,843.77 1,06,533.45
G 10.00 STEEL WORK
1 10.3 Providing and fixing in position collapsible steel shutters with vertical
channels 20x1 0x2 mm and braced with flat iron diagonals 20x5 mm
size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia
steel pulleys, complete with bolts, nuts, locking arrangement, stoppers,
handles, including applying a priming coat of approved steel primer. Sqm 0.00 11439.60 0.00
2 10.5.1 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm
M.S. gusset plates at the junctions and corners, all necessary fittings complete, including
applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal
3 10.15.1 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with
rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and
grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws
and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long
embedded in cement concrete block 15x10x10 cm of C.C. 1 :3:6 (1 Cement : 3 coarse
sand: 6 graded stone aggregate 20 mm nominal size) Kg 162.00 195.20 31,622.40
4 10.18 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of
internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked
for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3
mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S.
bar bent to shape as per standard drawing. Each 36.00 220.65 7,943.40
5 10.25 Steel work welded in built up sections/ framed work, including cutting,
hoisting, fixing in position and applying a priming coat of approved steel
primer using structural steel etc. as required.
a 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works KG 1191.90 172.60 2,05,721.94
6 10.27 Providing and fixing carbon steel galvanised ( minimum coating 5 micron)
dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480
N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6
grade sleeve, including drilling of hole in frame , concrete/ masonry, etc.
as per direction of Engineer-in-charge.
TOTAL (Carried Over to Summary of Civil Works) 3,20,852.74 0.00
H 11.00 FLOORING WORK
1 DSR 11.41A Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the
manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved
brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1
cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the
joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping
diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of
required thickness, leveling system and rubber mallet for placing the tiles gently
1.1 11.41A.1.3 Double charge vitrified tile polished finish of size (Size of Tile 600 x 1200 mm)
Digitally signed by PRIYA
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
1.2 11.41A.3.1 Glazed Vitrified tiles MatUAntiskid finish of size (Size of Tile 600 x 600 mm)
2 11.48 Grouting the joints of flooring tiles having joints of 3 mm width, using
epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10
kg of hardener and 0.20 kg of resin per kg), including filling / grouting and
finishing complete as per direction of Engineer-in-charge.
3 11.55 Providing and laying flamed finish Granite stone flooring in required
design and patterns, in linear as well as curvilinear portions of the building all complete as per
the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of
cement mortar 1 :4 (1 cement: 4 coarse sand) laid and jointed with cement slurry and pointing
with white cement slurry admixed with pigment of matching shade including rubbing, curing and
polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
3.1 11.55.1 Flamed finish granite stone slab Jet Black, Cherry Red, Elite
Brown, Cat Eye or equivalent. Sqm 6.12 3186.70 19,502.60
4 11.56 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as
well as curvilinear portions of the building all complete as per the architectural drawings with 18
mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse
sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with
pigment of matching shade including rubbing, curing and polishing etc. all complete as specified
and as directed by the Engineer-in-Charge.
4 11.56.1 Polished Granite stone slab jet black,cherry Red ,Elite Brown,Cat Eye or equivalent sqm 37.70 4481.30 1,68,922.60
TOTAL (Carried Over to Summary of Civil Works) 7,78,277.33 0.00
I 12.00 ROOFING
1 12.21 Providing and laying gola 75x75mm in cement concrete M15 grade including finishing with
cement mortar 1:3 (1 cement : 3 fine sand) as per standard design in 75x75 mm deep chase.
2 12.55 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm
x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70
and initial emittance> 0.75 on waterproof and sloped surface of terrace,
laid on 20 mm thick cement sand mortar in the ratio of 1 :4 (1 cement : 4
coarse sand) and grouting the joints with mix of white cement & marble
powder in ratio of 1 :1, including rubbing and polishing of the surface upto
3 cuts complete, including providing skirting upto 150 mm height along
the parapet walls in the same manner. Sqm 155 1703.95 2,63,941.86
3 12.45 Providing and fixing false ceiling at all heights including providing and
fixing of frame work made of special sections, power pressed from M.S.
sheets and galvanized with zinc coating of 120 gms/sqm (both side
inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm
wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre
to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia
x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle
hangers of 25x1 0x0.50 mm of required length with nuts & bolts of required
size and other end of angle hanger fixed with intermediate G.I. channels
45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to
which the ceiling section 0.5 mm thick bottom wedge of 80 mm with
tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre
to centre, shall be fixed in a direction perpendicular to G.I. intermediate
channel with connecting clips made out of2.64 mm dia x 230 mm long G.I.
wire at every junction, including fixing perimeter channels 0.5 mm thick
27 mm high having flanges of 20 mm and 30 mm long, the perimeter of
ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre,
with 25 mm long dry wall screws@ 230 mm interval, including fixing of
gypsum board to ceiling section and perimeter channel with the help of
dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and
finishing to a flush finish of tapered and square edges of the board with
recommended jointing compound , jointing tapes , finishing with jointing
compound in 3 layers covering upto 150 mm on both sides of joint and two
coats of primer suitable for board, all as per manufacturer's specification
and also including the cost of making openings for light fittings, grills,
diffusers, cutouts made with frame of perimeter channels suitably fixed,
all complete as per drawings, specification and direction of the Engineer
in Charge but excluding the cost of painting with :
12.45.3 12.5 mm thick tapered edge gypsum moisture resistant board Sqm 29 1529.10 44038.08
TOTAL (Carried Over to Summary of Civil Works) 3,33,612.54 0.00
J 13 FINISHING WORK
1 13.4 12 mm cement plaster of mix :
2 13.5 15 mm cement plaster on rough side of single or half brick wall of mix:
Digitally signed by PRIYA
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
3 13.16 6 mm cement plaster of mix :
4 13.21 Extra for providing and mixing water proofing material in cement plaster work in proportion per bag of
recommended by the manufacturers. 50KG
5 13.26 Providing and applying plaster of paris putty of 2 mm thickness over
plastered surface to prepare the surface even and smooth complete.
6 13.83.2 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile
Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture,
including applying additional coats wherever required to achieve even shade and colour. Two
7 13.85.3 Applying priming coats with primer of approved brand and manufacture,
having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on
wall surface having VOC content less than 50 grams/litre Sqm 28.80 73.95 2,129.76
8 13.45.1 Finishing walls with textured exterior paint of required shade :
New work (Two or more coats applied @ 3.28 ltr/10 sqm)
over and including priming coat of exterior primer applied @
9 13.47 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required
i 13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of
exterior primer applied @ 2.20 kg/10 sqm) Sqm 408.84 171.10 69,952.01
10 13.50 Applying priming coat :
ii 13.50.3 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel
galvanised iron/ steel works Sqm 183.88 67.40 12,393.69
11 13.62 Painting with synthetic enamel paint of approved brand and manufacture of required colour to
give an even shade :
i 13.62.1 Two or more coats on new work over an under coat of suitable
shade with ordinary paint of approved brand and manufacture Sqm 183.88 226.25 41,603.44
12 13.68.1 French spirit polishing : Two or more coats on new works including a coat of wood filler Sqm 29.11 446.25 12,990.34
13 MR-6 Providing and fixing 24 gauge Chicken Wire mesh in junction of block work & RCC works at
corner/wall surface as per direction of Engineer-In-Charge. Sqm Rate only 266.86
TOTAL (Carried Over to Summary of Civil Works) 14,09,656.84 0.00
K 21.00 ALUMINIUM WORK
1 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded
built up standard tubular sections/appropriate Z sections and other sections of approved make
conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with
expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and
sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free,
straight, mitred and jointed echanically wherever required including cleat angle, Aluminium snap
beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per
architectural drawings and the directions of Engineer-in-charge. Glazing and paneling to be paid
for separately) :
a) 21.1.1 For fixed portion.
i 21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) KG 2.50 530.90 1,327.25
b 21.1.2 For shutters of doors, windows & ventilators including
providing and fixing hinges/ pivots and making provision
for fixing of fittings wherever required including the cost of
EPDM rubber / neoprene gasket required (Fittings shall be
paid for separately)
1 21.1.2.2 Powder coated aluminium (minimum
thickness of powder coating 50 micron) KG 1.50 634.45 951.68
2 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with
EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the
directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
i 21.3.2 With float glass panes of 5 mm thickness (weight not less
TOTAL (Carried Over to Summary of Civil Works) 3,784.18 0.00
L 22.00 WATER PROOFING
Digitally signed by PRIYA
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
1 22.3 Providing and laying water proofing treatment to vertical and horizontal
surfaces of depressed portions of W.C., kitchen and the like consisting of:
(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water
proofing compound conforming to IS : 2645 in recommended proportions
including rounding off junction of vertical and horizontal surface.
(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand)
mixed with water proofing compound in recommended proportion
including rounding off junction of vertical and horizontal surface.
(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7
kg. per sqm of area.
(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of
PVC sheet should be 100 mm wide and pasted to each other with bitumen
2 22.7 Providing and laying integral cement based water proofing treatment
including preparation of surface as required for treatment of roofs,
balconies, terraces etc consisting of following operations:
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement
admixed with water proofing compound conforming to IS. 2645 and
approved by Engineer-in-charge over the RCC slab including adjoining
walls upto 300 mm height including cleaning the surface before treatment.
(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm
to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse
sand) admixed with water proofing compound conforming to IS : 2645
and approved by Engineer-in-charge over 20 mm thick layer of cement
mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-in-charge
to required slope and treating similarly the adjoining walls upto 300 mm
height including rounding of junctions of walls and slabs.
(c) After two days of proper curing applying a second coat of cement slurry
using 2.75 kg/ sqm of cement admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge.
(d) Finishing the surface with 20 mm thick jointless cement mortar of mix
1:4 (1 cement :4 coarse sand) admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge including
laying glass fibre cloth of approved quality in top layer of plaster and
finally finishing the surface with trowel with neat cement slurry and making
pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded
with water for a minimum
period of two weeks for curing and for final test. “All above operations to be
done in order and as directed and specified by the Engineer-in-Charge”:
2.01 22.7.1 With average thickness of 120 mm and minimum thickness
TOTAL (Carried Over to Summary of Civil Works) 1,45,156.24 0.00
ALL SUB-HEAD TOTAL 1,12,77,134.93 1,06,533.45
GRAND TOTAL 1,13,83,668
GRAND TOTAL 1,13,83,668
Digitally signed by PRIYA
PROJECT: PROPOSED KENDRIYA VIDYALAYA CAMPUS AT BARKATHA, DIST.- HAZARIBAGH, JHARKHAND 22.10.26
STAFF QUARTERS BUILDING (G+1)
DETAILED ESTIMATE OF INTERNAL PLUMBING
Amt. As per Amt. As per
S.No. DSR -2023 / NS Description Unit Qty. Rate (Rs.)
Sub- Head - ( I ), Sanitary Fixture & CP Fittings
1 DSR-17.1 Providing and fixing water closet squatting pan (Indian type
W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low
fixtures complete, including cutting and making good the walls
andlevel white P.V.C. flushing cistern, including flush pipe, with
manually controlled device (handle lever) conforming to IS :
7231, with all fittings and floors wherever required :
DSR-17.1.1 White Vitreous china Orissa pattern W.C. pan of size
580x440 mm with integral type foot rests Each 4 6767.4 27,069.60
2 DSR-17.3 Providing and fixing white vitreous china pedestal type water
closet (European type) with seat and lid, 10 litre low level white
vitreous china flushing cistern & C.P. flush bend with fittings &
C.I.brackets, 40 mm flush bend, overflow arrangement with
specials of standard make and mosquito proof coupling of
approved municipal design complete, including painting of
fittings and brackets, cutting and making good the walls and
floors wherever required :
DSR-17.3.1 W.C. pan with ISI marked white solid plastic seat and lid Each 4 8006.6 32,026.40
3 DSR-17.7A Providing and fixing wash basin with C.I. brackets, 15 mm dia CP
Brass single hole basin mixer of approved quality and make,
including painting of fittings and brackets, cutting and making
good the walls wherever required:-
(a) White Vitreous China Wash basin size 550x400 mm
with a 15 mm CP Brass single hole basin mixer Each 8 3960.55 31,684.40
4 DSR/17.10 Providing and fixing Stainless Steel A ISi 304 (18/8) kitchen sink
as per IS: 13983 with C.I. brackets and stainless steel plug 40
mm, including painting of fittings and brackets, cutting and
making good the walls wherever required :
DSR/17.10.1 Kitchen sink with drain board
DSR/17.10.2 Kitchen sink with drain board
5 DSR-18.22 Providing and fixing C.P. brass shower rose with 15 or 20 mm
DSR-18.22.1 150 mm diameter Each 8 222.35 1,778.80
6 DSR-17.31 Providing and fixing 600x450 mm beveled edge mirror of
superior glass (of approved quality) complete with 6 mm thick
hard board ground fixed to wooden cleats with C.P. brass screws
and washers complete. Each 8 1607.95 12,863.60
7 DSR-17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm
long, 200 mm wide with minimum distances of 37 mm from wall
face with concealed fittings arrangement of approved quality
and colour,weighing not less than 88 gms.
8 DSR-17.73 Providing and fixing PTMT towel rail complete with brackets
fixed to wooden cleats with CP brass screws with concealed
fittings arrangement of approved quality and colour.
DSR-17.73.2 600 mm long towel rail with total length of 645 mm, width
78 mm and effective height of 88 mm, weighing not less
9 DSR-18.65 Providing and fixing PTMT soap Dish Holder having length of
138mm,breadth 102mm, height of 75mm with concealed fitting
arrangements,weighing not less than 106 gms.
10 DSR-17.71 Providing and fixing PTMT liquid soap container 109 mm
wide,125 mm high and 112 mm distance from wall of standard
shape with bracket of the same materials with snap fittings of
approved quality and colour, weighing not less than 105 gms.
11 DSR/17.22B Providing and fixing CP Brass Single lever telephonic wall mixer
of quality & make as approved by Engineer in charge.
(a) 15 mm nominal dia Each 8 6940.75 55,526.00
12 DSR/17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin
including P.V.C. waste fittings complete.
Digitally signed Page 1 of 4
Amt. As per Amt. As per
S.No. DSR -2023 / NS Description Unit Qty. Rate (Rs.)
DSR/17.28.2 Flexible pipe
13 DSR/17.69 Providing and fixing PTMT Waste Coupling for wash basin and
sink, of approved quality and colour.
DSR/17.69.1 Waste coupling 31 mm dia of 79 mm length and 62mm breadth
weighing not less than 45 gms Each 8 115.3 922.40
DSR/17.69.2 Waste coupling 38 mm dia of 83 mm length and 77mm breadth,
weighing not less than 60 gms Each 8 122.40 979.20
DSR/17.70 Providing and fixing PTMT Bottle Trap for Wash basin and sink.
DSR/17.70.1 Bottle trap 31mm single piece moulded with height of 270 mm,
effective length of tail pipe 260 mm from the centre of the
waste coupling, 77 mm breadth with 25 mm minimum water
seal, weighing not less than 260 gms. Each 8 367.1 2,936.80
DSR/17.70.2 Bottle trap 38 mm single piece moulded with height of 270 mm,
effective length of tail pipe 260 mm from the centre of the
waste coupling, 77 mm breadth with 25 mm minimum water
seal, weighing not less than 263 gms. Each 8 0.00 -
15 DSR/18.49 Providing and fixing C.P. brass bib cock of approved quality
conforming to IS:8931 :
DSR/18.49.1 15 mm nominal bore Each 16 506.8 8,108.80
DSR/18.50 Providing and fixing C.P. brass long nose bib cock of approved
quality conforming to IS standards and weighing not less than
DSR/18.50.1 15 mm nominal bore Each 8 820.7 6,565.60
16 DSR/18.53 Providing and fixing C.P. brass angle valve for basin mixer and
geyser points of approved quality conforming to IS:8931
DSR/18.53.1 15 mm nominal bore Each 16 574.3 9,188.80
17 NS Providing, fixing, testing and commissioning of heavy duty chrome
plated brass health faucet conforming to relevant IS/CPWD
specifications, comprising trigger operated hand spray, SS braided
flexible hose of 1.2 m length, wall bracket, 15 mm CP brass angle
valve with wall flange, complete with all accessories, connection to
water supply line, cutting/chasing, making good the wall and
testing complete in all respects.
Approved Make: Jaquar / Hindware / Cera / Kohler / Parryware /
Equivalent approved.
Sub- Head - ( II ), Soil, Waste, Vent & Rain Water pipe
1 MR Supply fixing and testing UPVC SWR pipe confirming to IS:13592
for waste connection from wash basin and pantry sink to floor
trap or thermosyphonage pipe with solvent cement joints
including all the fittings laid above the fall ceilling connected in
wall etc the shall include wall chiseling making good the same in
cement mortar etc complete include with all necessary support
like GI hangers support GI grip and bolts GI clamp etc in fall
ceilling area as well as supplying and fixing GI slotted angle iron
bracket hangers supports with necessary drilling holes to suit
the insertion of pipe clamps deburring brick work concrete
supports etc as per detailed drawing for supporting soil waste
and rain water pipes and water supply pipes in shaft with
suitable GI clamps GI bolts anchor nuts and washers fixed on
shaft walls, outer walls etc.
2 MR Providing and fixing M.S. holder bat clamps of approved design
including cost of cutting holes and making good the walls etc.
3 MR Providing fixing and testing UPVC SWR plain ring type 90 Deg
Bend with door IS:14735
4 MR Providing fixing and testing UPVC SWR plain ring type 45 Deg
Digitally signed Page 2 of 4
Amt. As per Amt. As per
S.No. DSR -2023 / NS Description Unit Qty. Rate (Rs.)
5 MR Providing fixing and testing UPVC SWR plain Single Y Branch
with Door type fitting IS:14735
6 MR Providing fixing and testing UPVC SWR plain Tee Branch with
Door type fitting IS:14735
7 MR Providing and fixing and testing UPVC single floor trap with all
necessary UPVC pipes connection extension pipe and reducing
tee for water pipe connections from toilet and wash area.
8 MR Providing and fixing 75 mm dia, 3 mm thick Stainless steel
grating with frame for floor traps or drains of required pattern
including cutting and making good the floors complete.
9 DSR /4.1 Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering - All work
up to plinth level:
DSR /4.1.3 1:2:4 (1 cement :2 coarse sand: 4 hard stone aggregate 20mm
and down gauge). Cum 0.60 7878.5 4,727.10
10 DSR/12.22 Making khurras 45x45 cm with average minimum thickness of 5
cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m
x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1
cement : 3 coarse sand) and a coat of neat cement, rounding the
edges and making and finishing the outlet complete.
11 DSR /12.41 Providing and fixing on wall face unplasticised Rigid PVC rain
water pipes conforming to IS : 13592 Type A, including jointing
with seal ring conforming to IS : 5382, leaving 10 mm gap for
thermal expansion, (i) Single socketed pipes.
DSR /12.41.2 110 mm diameter Metre 45 377.4 16,983.00
12 DSR /12.42 Providing and fixing on wall face unplasticised - PVC moulded
fittings/ accessories for unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for thermal
DSR /12.42.1 Coupler
DSR /12.42.3 Single tee with door
DSR /12.42.5 Bend 87.5
13 DSR /12.43 Providing and fixing unplasticised -PVC pipe clips of approved
design to unplasticised - PVC rain water pipes by means of
50x50x50 mm hard wood plugs, screwed with M.S. screws of
required length, including cutting brick work and fixing in
cement mortar 1:4 (1 cement : 4 coarse sand) and making good
the wall etc. complete.
14 DSR /12.44 Providing and fixing to the inlet mouth of rain water pipe cast
iron grating 15 cm diameter and weighing not less than 440
grams. Each 6 54.7 328.20
15 DSR-18.58 Providing and fixing PTMT grating of approved quality and
18.58.1 Circular type
18.58.1.1 100 mm nominal dia Each 16 37.6 601.60
Sub- Head - ( III ), Internal Water Supply
1 DSR /18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all
CPVC plain & brass threaded fittings, including fixing the pipe
with clamps at 1.00 m spacing. This includes jointing of pipes &
fittings with one step CPVC solvent cement and testing of joints
complete as per direction of Engineer in Charge.
Internal work - Exposed on wall
Digitally signed Page 3 of 4
Amt. As per Amt. As per
S.No. DSR -2023 / NS Description Unit Qty. Rate (Rs.)
DSR /18.7.1 15 mm nominal outer dia Pipes Metre 286.8 -
DSR /18.7.2 20 mm nominal outer dia Pipes Metre 335 -
DSR /18.7.3 25 mm nominal outer dia Pipes Metre 40 401.55 16,062.00
DSR /18.7.4 32 mm nominal outer dia Pipes Metre 518.55 -
DSR /18.7.5 40 mm nominal outer dia Pipes Metre 702.95 -
DSR /18.7.6 50 mm nominal outer dia Pipes Metre 934.15 -
2 DSR /18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all
CPVC plain & brass threaded fittings, i/c fixing the pipe with
clamps at 1.00 m spacing. This includes jointing of pipes &
fittings with one step CPVC solvent cement and the cost of
cutting chases and making good the same including testing of
joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the
DSR/18.8.1 15 mm nominal outer dia Pipes Metre 497.8 -
DSR/18.8.2 20 mm nominal outer dia Pipes Metre 30 537.6 16,128.00
DSR/18.8.3 25 mm nominal outer dia Pipes Metre 30 627.25 18,817.50
DSR/18.8.4 32 mm nominal outer dia Pipes Metre 739.3 -
3 DSR/18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply including all
CPVC plain & brass threaded fittings This includes jointing of
pipes & fittings with one step CPVC solvent cement, trenching,
refilling & testing of joints complete as per direction of Engineer
Pipe running at terrace level
DSR/18.9.6 50 mm nominal inner dia Pipes Metre 50 794.25 39,712.50
DSR/18.9.7 65 mm nominal inner dia Pipes Metre 1674.4 -
DSR /18.9.8 80 mm nominal inner dia Pipes Metre 2166.35 -
DSR /18.9.9 100 mm nominal inner dia Pipes Metre 3271.7 -
DSR /18.9.10 150 mm nominal inner dia Pipes Metre 6822.7 -
4 DSR/18.48 Providing and placing on terrace (at all floor levels) polyethylene Per 3000 11 33,000.00
water storage tank IS: 12701 marked, with cover and suitable litre
locking arrangement and making necessary holes for inlet, outlet
and overflow pipes but without fittings and the base support for
5 MR Providing and fixing forged brass operated ball valve of full flow
of superior quality having minimum working pressure of 16
5.1 25 mm nominal bore Each 12 3262.00 39,144.00
5.2 50 mm nominal bore Each 1 9015.00 9,015.00
Digitally signed Page 4 of 4
SUMMRY OF INTERNAL ELECTRICAL WORKS TYPE-III ( G+1) QUARTER AT KV
HAZARIBAGH (1 BLOCK)
SL. NO DESCRIPTION TOTAL
1 SCHEDULE ITEMS (PART-A)
i) TOTAL OF SUB HEAD :1 7,39,751.00
ii) TOTAL OF SUBHEAD :2 39,791.00
iii) TOTAL OF SUBHEAD :3 18,302.00
iv) TOTAL OF SUBHEAD :4 61,438.00
v) TOTAL OF SUBHEAD :5 70,696.00
vi) TOTAL OF SUBHEAD :6 2,286.00
TOTAL OF SCHEDULE ITEMS (PART-A) 9,32,264.00
2 TOTAL OF NON SUBHEAD ITEM (PART-B) 1,43,169.00
TOTAL OF PART-A +PART-B (SCHEDULE-DSR-2025 &
NOIN SCHEDULE ITEMS)
Digitally signed by PRIYA
ESTIMATE FOR INTERNAL ELECTRICAL WORKS TYPE-III ( G+1) QUARTER AT KV HAZARIBAGH
Sl. Item Description UNIT QTY RATE AMOUNT (DSR- AMOUNT (NON
No. Code. 2025) SCHEDULE
SCHEDULE ITEMS (DSR-2025) (PART-A)
SUBHEAD :1_WIRING
1 D.S.R Point Wiring in Medium Class PVC Conduit, with Modular type Switch: Wiring
1.10 for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/
( Page No.-HFFR PVC insulated copper conductor single core cable in surface/recessed Medium
03) Class PVC conduit, with modular type switch, modular plate, suitable size of GI box
and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor
single core cable etc as required.
2 D.S.R Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated Point 2 1,803.00 3,606.00
1.11 copper conductor single core cable in surface / recessed medium class PVC conduit,
( Page No.-2way modular switch, modular plate, suitable GI box and earthing the point with
03) 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as
3 D.S.R Wiring for light/power plug with 2x4 Sq.mm FRLS/HFFR PVC insulated copper Mtr. 300 373.00 1,11,900.00
1.12 conductor single core cable in surface/recessed Medium Class PVC conduit along
( Page No.-with 1 No. 4 Sq.mm FRLS/HFFR PVC insulated copper conductor single core cable
03) for loop earthing etc. as required.
4 D.S.R Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of
1.14 FRLS/HFFR PVC insulated copper condcutor, single core cable in surface/ recessed
( Page No.-Medium Class PVC conduit as required.
5 D.S.R Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper Mtr. 360 54.00 19,440.00
1.18 conductor PE insulated, shielded with fine tinned copper braid and protected with
( Page No.-PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
6 D.S.R Supplying and fixing of following sizes of medium class PVC conduit along with
1.21 accessories in surface/recess including cutting the wall and making good the same
( Page No.-in case of recessed conduit as required.
7 D.S.R. Supplying and fixing following modular switch/ socket on the existing modular plate
1.24 & switch box including connections but excluding modular plate etc. as required.
1.24.4 3 pin 5/6A socket outlet Each 24 136.00 3,264
1.24.5 6 pin 15/16 amp socket outlet Each 20 219.00 4,380
1.24.7 TV antenna socket outlet Each 12 168.00 2,016
1.24.8 Bell push Each 4 159.00 636
8 D.S.R. Supplying and fixing two module stepped type electronic fan regulator on the Each 16 402.00 6,432.00
1.25 existing modular plate switch box including connections but excluding modular
( Page No.-plate etc. as required.
9 D.S.R. Supplying and fixing following size/ modules, GI box along with modular base &
1.27 cover plate for modular switches in recess etc. as required.
1.27.1 1or 2 module (75mmx 75mm) ( For TV Out Lets) Each 12 354.00 4,248.00
10 D.S.R. Supplying and fixing suitable size GI box with modular plate and cover in front on Each 28 545.00 15,260.00
1.31 surface or in recess, including providing and fixing 3 pin 5/6 A modular socket
( Page No.-outlet and 5/6 A modular switch, connections etc. as required.
11 D.S.R. Supplying and fixing suitable size GI box with modular plate and cover in front on Each 16 659.00 10,544.00
1.32 surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular
( Page No.-socket outlet and 15/16 A modular switch, connections etc. as required.
12 D.S.R. Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden Each 40 104.00 4,160.00
1.33 block including connections etc. as required
13 D.S.R. Supplying and fixing brass batten/ angle holder including connection etc. as Each 32 154.00 4,928.00
1.34 required.
14 D.S.R. Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as Each 4 112.00 448.00
1.38 required.
15 D.S.R. Installation, Testing and Commissioning of exhaust fan in the existing opening,
1.50 including making good the damage, connection, testing, commissioning etc. as
( Page No.-required.
16 D.S.R. Supplying and fixing suitable size GI box with modular plate and cover in front on Each 12 757.00 9,084.00
1.56 surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular
( Page No.-socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For
11) light plugs to be used in non residential buildings).
17 D.S.R. Supplying & fixing suitable size GI box with modular plate and cover in front on Each 8 807.00 6,456.00
1.57 surface or in recess including providing and fixing 25 A modular socket outlet and
( Page No.-25 A modular SP MCB, "C" curve including connections, painting etc. as required.
TOTAL OF SUB HEAD :1 7,39,751.00
SUBHEAD :2 MCCB,MCB & DB'S
18 D.S.R 2.3 SPN DB:- Supplying and fixing following way, single pole and neutral, sheet steel,
( Page No.-MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus
14) bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including
earthing etc. as required. (But without MCB/RCCB/Isolator)
2.3.4 16 way, Double door Each 4 3,367.00 13,468.00
19 D.S.R MCB:- Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve,
2.10 miniature circuit breaker suitable for inductive load of following poles in the
( Page No.-existing MCB DB complete with connections, testing and commissioning etc. as
20 D.S.R Supplying and fixing following rating, double pole, single phase and neutral), 240
2.14 V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the
( Page No.-existing MCB DB complete with connections, testing and commissioning etc. as
21 D.S.R Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild Each 1 315.00 315.00
2.21 steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with
( Page No.-inscription in single red colour on front side as required.
TOTAL OF SUBHEAD :2 39,791.00
SUBHEAD :3 EARTHING SYSTEM
22 D.S.R. Earthing with G.I. earth plate 600 mm X 600 mm X6 mm thick including Each 2 8,351.00 16,702.00
5.4 ( Page accessories, and providing masonry enclosure with cover plate having locking
No.-30) arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt
23 D.S.R. Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip Mtr 10 160.00 1,600.00
5.9 earth electrode, including connection/ terminating with G.I. nut, bolt, spring,
( Page No.-washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of
31) G.I. nut bolt & spring washer spaced at 50mm)
TOTAL OF SUBHEAD :3 18,302.00
SUBHEAD :4 LIGHTNING CONDUCTOR
24 D.S.R. Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, Each 4 609.00 2,436.00
6.1 G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate
( Page No.-including holes etc. complete as required.
25 D.S.R. Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for Each 110 148.00 16,280.00
6.6 lightning conductor complete as required.(For horizontal run)
26 D.S.R. Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for Each 35 238.00 8,330.00
6.7 lightning conductor complete as required.(For vertical run)
27 D.S.R. Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm Each 4 140.00 560.00
6.10 long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete
( Page No.-as required
28 D.S.R. Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and Each 4 7,658.00 30,632.00
5.2 ( Page providing masonry enclosure with cover plate having locking arrangement and
No.-30) watering pipe etc. with charcoal/ coke and salt as required.
29 D.S.R. Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip Mtr 20 160.00 3,200.00
5.9 earth electrode, including connection/ terminating with G.I. nut, bolt, spring,
( Page No.-washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of
31) G.I. nut bolt & spring washer spaced at 50mm)
TOTAL OF SUBHEAD :4 61,438.00
SUBHEAD :5 LED LIGHT & FAN
Note:- All LED Light fittings LM 79 and LM 80 reports need to be submitted with all
accessories and 50,000.00 hrs shall as burning life. Samples of alltype LED light
fixtures are to be submitted to the Engineering Incharge and each LED Light
should have minimum 100lm/W for the approval prior to procurement of light
30 D.S.R. LED Down lighter (COB Type) (System lumen efficacy ≥105 < 120 lm/Watt
Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down
lighter (Round/ Square/ Rectangular) COB Type of following body material and
construction as per IS : 10322 with driver as per the requirement with Driver
efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz,
Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV
with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80,
UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life
time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with
70% of initial Lumen maintained till life ends, CCT 3000°K
/4000°K/5700°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color
Matching) <3, Maximum power consumption should not more than the
specified rating and Fixture shall be confirming to relevant BIS standards.
Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing
Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR,
PVC insulated copper conductor single core cable and earthing etc. as required
with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120
lm/Watt output . LM79 & LM80 Test report and all testing required for LED
fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by
Engineer-in-Charge as per requirement. (Thermal management: heat sink of
8.4.3 12 -15 watthousing such that LED junction temperature shall not rise above 90°C)
aluminium Each 16 1,042.00 16,672.00
31 D.S.R. LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).
8.9 Supplying, Installation, Testing & Commissioning of LED surface mounted Batten
( Page No.-light of following body material and construction as per IS : 10322 with driver
45) (Replaceable) as per the requirement with Driver efficiency >85%, Operating
voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40
°C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD <
10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life
time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with
70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K
/6500°K (As per ANSI Bin), SDCM(Standard DeviationColour Matching) <3,
Maximum power consumption should not more than the specified rating and Fixture
shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/
Embossing/ Screen printing on housing. complete in all respect i/c external
connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single
core cable and earthing etc. as required with Minimum 5 year OEM warranty.
System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and
all testing required for LED fixtures as per BIS shall be submitted. Shape size and
CCT shall be as approved by Engineer-in-
Charge as per requirement. (Thermal management: heat sink of aluminium housing
such that LED junction temperature shall not rise above 90°C). Powder coated die
cast /Extruded aluminium Body (Thickness > 1.20 mm)
32 D.S.R. LED Street light fixture, powder coated pressure die cast aluminium body (System
8.12 lumen efficacy ≥105 <120 lm/Watt) (to use as building outer light)
Supplying, installation, Testing & Commissioning of Street light (to be use as
Building Outer Light) LED fixture powder coated pressure die cast aluminium body
with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-
270 Volt AC, frequency 50/60 hz, Operating temp range -5°C to 50°C, internal
surge protection of 5 KV L,N,E as per IEC 61000-4-5,61000-3-2, P. F.≥0.95, IP-
66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per
CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the
road and the project requirement., suitable to fit in up to 65mm dia pipe, life time
(LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of
initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11
report,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard
Deviation Colour Matching) <5, Maximum power consumption should not more
than the specified rating and Fixture shall be of relevant BIS standard complete in
all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated
copper conductor single core cable and earthing etc. as required with Minimum 5
year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 &
LM80 Test report and all testing required for LED fixtures as per BIS shall be
8.12.11 45 Shape size
W LED STRRET LIGHTand CCT shall be as approved by Engineer-in-Charge as per Each 2 1,366.00 2,732.00
33 D.S.R. Brush Less Direct Current (BLDC) Fan without Remote:-
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less
Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium
alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope,
copper winding, steel/Al body Power Factor not less than 0.9, Service Value
(CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD
(Total Harmonic Distortion) less than 10%, suitable for operation with regulator
for speed control and all remaining accessories including safety pin, nut bolts,
washers, temperature rise=75 0C (max.), insulation resistance more than 2
mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan
compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR,
PVC insulated copper conductor single core cable and earthing etc. as required.
9.2.3 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
TOTAL OF SUBHEAD :5 70,696.00
SUBHEAD :6 GI PIPE
1 DSR-2025 Providing, laying and fixing following dia G.I. pipe (medium class) in ground
15.13 complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as
( Page No.-required
TOTAL GI SUBHEAD :6 2,286.00
TOTAL OF SCHEDULE ITEMS (PART-A) 9,32,264.00
NON SCHEDULE ITEMS (PART-B)
(ELECTRICAL & ELV)
LED LIGHT FIXTURES
2 N.S. Note:- All LED Light fittings LM 79 and LM 80 reports need to be submitted with all
accessories and 50,000.00 hrs shall as burning life. Samples of alltype LED light
fixtures are to be submitted to the Engineering Incharge and each LED Light
should have minimum 100lm/W for the approval prior to procurement of light
(N.S.-i) Supply of 9W/10W LED Bulb (Luminous Flux- 600lm, CCT-6500K (Cool W 9/10 watt Each 32 104.00 3,328.00
LED Bulb, B22, 6500 Khite), CRI-80, Rated Voltage- 220V/ 240V. Beam Angle- 120
(N.S.-ii) Supply and fixing of 10 W LED Type Bulk Head luminaire (Metal Body) with Each 4 2,375.00 9,500.00
minimum efficency 100lm/w in comprising of pressure die cast housing, acrylic
diffuser, IP 66 protection and complete with ectronic driver etc. dirctly on wall or
ceiling including connection with 1.5 Sq. mm, FRLS PVC cu conductor cable etc. as
required with lamp
(N.S.iii) Supply, installation, testing and commissioning of 2ft 10W LED Batten delivering Each 8 621.00 4,968.00
an initial system lumen of 1000 lumens & the luminaire shall be with system
efficacy ≥ 100 lm/W. The housing should be made of Extruded Aluminium with
polycarbonate diffuser. The operating CCT shall be 6500K with CRI of ≥80. The
luminaire shall be with BIS Registered electronic driver with input voltage range of
150 to 270V , PF ≥ 0.9 ,THD ≤ 10%, 50,000 Hrs LED Life with L70 Criteria and
Ingress Protection of IP20. Luminaire shall have minimum surge protection of
2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by
LED manufacture along with Photo Biological Safety Standard.
3 N.S. All Exhaust shall be of minimum 2 years of Warranty. Samples of all Fans are to
be submitted to the Engineer-in- charge for the approval prior to procurement of
(i) SITC of 230mm 230V AC single phase,1440RPM Exhaust Fan, double ball bearing Each 12 2,002.00 24,024.00
(Metal Body, metalick blade,- Light Duty) exhaust fan as required.
4 (N.S. i) Meter Panel for Type-III Quarers (4 Units in One Block) 2 BHK (G+1)
Supplying, designing, manufacturing and commissioning in correct alignment
position, effecting proper connection of all incomer and outgoing feeders of Smart
Meter Panel , unloading at site, shifting to loaction, fitting, fixing and testing of
meter Panel, fabricated out of 2 mm thick (14SWG) CRCA sheet steel for Load
bearing and 1.6 mm or 16SWG Unload Bearing, dust and vermin proof with
reinforcement of suitable size iron channel, size 35mmx35mmx4mm with proper
lifting arrangement, (IP-42) fully compartmentalized cubical type (folded joints
construction), wall mounted, totally enclosed, accessories, all out going feeders
protection & meters as required, factory built sheet steel enclosed extendable panel
and suitable for use on 415V, 3 phase, AC Supply, 4 wire, 50 C/S, system having
25 KA fault capacity, housed with incoming and outgoing aluminum bus bars,
interconnection, interlocking between feeders etc. with indicating lamps, push
buttons, necessary accessories, all out going feeders protection & meters as
The sheet steel under go minimum 7 tanks treatment followed by finishing of
powder coating of minimum 60 micron thickness, duly compartmentalized having
accessories mounted inside the cubical panel, earthing with 2 Nos. earth studs.
The Smart Energy Meter Panel shall be totally enclosed, completely dust and
vermin proof. Synthetic rubber gaskets (neoprene/DPDM) between all adjacent
units and beneath all covers shall be provided to render the joints dust proof. All
doors and covers shall be fully gasketed and shall be lockable. Doors shall have
concealed hinges. All the doors shall be suitably reinforced by channel to provide
rigidity. Panel shall have suitable cable entry from bottom/Top and suitable
arrangement for aluminum cable termination.
The Smart Energy Meter Panel shall be provided with a thermostatically controlled
heating arrangement (200 W) to take care of high humidity conditions. A 6/16A
socket with sitch as service outlet (single phase) and 1 no. 10W LED LAMP with
holder shall be provided in one of the compartments as service outlet in the panel.
The complete panel shall be fuse less type, for control circuits 2A SP MCB's to be
For the protection of equipment & feeders, switchgear shall be provided with
required O/C & S/C releases. Selection of switchgear rating shall be made on the
basis of load current & fault withstand capacity.
Panel Builder will provide shop drawing SLD & GA drawing along with BOM with
CAT. No. of each and every components and switch gears of Meter Panel for
approval of Consultant or concirned department. Inspection of the Meter Panel
shall be carried out at Panel Builder's factory by the Consultantor departmental
engineers before final delivery for that all arrangements shall be made by the
Location :- Near Stair.
The Name Plate for each feeder must be in Anodized Aluminium Sheet.
MCCB:- L&K-DSine/ LEGRAND-DPX³/SCHNEIDER-NSX/ SIMENS- 3VJ-3WJ
MCB- C Series 10kA _ Legrand- DX³/Schneider- ACTI-9/Siemens- Beta Guard/ L&K-
Make of Smart Energy Meter (Kwh- Meter) :- L&K, Socomo/Secure, HPL.
Name of Panel Bulder:- Name of Panel builders -Name of Panel builders:- EAP
Kolkat, Green Galaxy Kolkata, JMD, Kokar, Ranchi, STEC, SIRDO, BIT, Meshra,
Meditiron, SIRDO, BIT Meshra, Ranchi. Amichand Technology, Jamshedpur.
The panel includes 415V, 100A, 3Ph, 25KA, 50Hz, TPN Electrolytic Aluminium Bus
Bar (E91E) GI Earth Bus with removable glands plates, cable glands at sending and
receiving ends, including connection with outgoing feeders complete in all respects.
The electrolytic Aluminium bus bar as per I:S 5082 of suitable length and insulated
by heat shrinkable sleeves Red, yellow, Blue and Black as R Y B & N. The current
density of bus bar shall be minimum 0.8 A / sq mm. Minimum clearance between
live parts / neutral to earth shall be 19 mm. However clearances between terminals
at components shall be as per applicable individual standard for components.
Interconnections between the main bus bars and individual units shall be made
using vertical / horizontal Bus Bar to individual MCB shall be made with 2.5, 4 & 6
Sq mm FRLS PVC Cu. wire aluminium bus bars of adequate rating. AL. Bus Bar will
be supported on insulators made of non-hygroscopic, non-inflammable material
with tracking index equal to or more than that defined in BIS.
1 Set of Fabrication part of LT Panel & busbar system, with AL. bus bar and
interconnection FRLS cables) in CRCA Sheet Steel enclosure (IP-42) without
components. Name of Panel builders - as per approved make list.
1 Sets Multifunction Meter having LED mete display accuracy Class 1 as per IEC
62053-21, should have an active RS-485 port, in built RTC, Aux Supply: 44-
277Vac/dc. Parameters: Volts, Amps, PF, THD, F, W, Wh, VA, VAh, Var, Varh,
Runhrs, Onhrs Interrupts, THD for V&I per phase, individual harmonics for V&I upto
15th level complying with IEC61557-12. Min/Max for eight parameters. Sampling
rate: 64 samples per cycle. MAKE- L& K / SCCHEIDER-EM6400/ Legrand-
3 Nos. CT of different power as per incomer & out going /5VA -5 class one Epoxy
resin cast CT (3 Nos.)=1 Set.
3 Sets Phase indicating light shall be protected by 2 Amps SP MCB's for incomer &
1 No. 63 A F/P MCCB (25kA) with adjustable thermomagnetc release type with S/C
& O/L protection, and front rotary Handle and spreader links in both ends Cable
Size 3.5 C 35 Sq.mm Al,Ar, Cable)
5 nos. 40 DP/10kA/C Serise MCB(1 no. as spare) & 4 nos. 220V/Single Phase, 2
Wires 10-60A LCD Smart Energy Meter with optical port and box, Frequency 50Hz,
Complying to IP51, with LCD Display, kWh LED, encrypted STS based token System
with RS485 Modbus and polycarbonate box along with Vending/Server charges per
meter per annum with 40A DP /10 kA MCB including 32 Sq.mm. 3 studs brass
terminal. (4 nos for quarters and 1 no. as spare) LCD Display Smart Energy meter
in panel. (Note:- Location of all kWh Meter shall be out side the Meter Panel as per
the latest Guide lines of SEB, and shall be installed in a Systematic formation and
demarcation with respective Quarter no. and Block No.)
a) 5 nos. 40A/DP/10kA/ C Series MCB (1 no. As spare or for future use )
b) 4 no. 220V/single Phase, 2 Wires 230V 10-60A LCD energy Smart Meter with
optical port and box.
c) 5 nos. 32 Sq.mm. 3 studs brass terminal (1 no. as spare or for future use)
Total Cost of Smart Energy Meter Panel of Type III, one Residential Block (G+1) Sets 1 98,557.00 98,557.00
5 Accessories for TV SYSTEM
N.S. Supply, erection, testing and commissioning of splitter / tap off mounted in suitable
sizes MS boxes for MATV system and shall be suitable for interactive system.
i) Four Way (S-4) (Make:- Reputed of as directed by I/E or Consultant Each 2 528.00 1,056.00
ii) Four way tap off (T4) (Make:- Reputed of as directed by I/E or Consultant) Each 2 868.00 1,736.00
TOTAL OF NON SUBHEAD ITEM (PART-B) 1,43,169.00
TOTAL OF PART-A +PART-B (SCHEDULE-DSR-2025 & NOIN SCHEDULE 10,75,433.00
PROPOSED CONSTRUCTION OF PRINCIPAL QUARTER (G+0)
ABSTRACT OF COST - CIVIL WORKS
SOR-2023 NON SOR
Sl. No. SOR-2022 DESCRIPTION
A 2 EARTH WORKS 1,79,036.27 -
B 4 CONCRETE WORKS 2,32,736.82 -
C 5 REINFORCED CEMENT CONCRETE WORK 28,96,936.06 -
D 6 BRICK WORK 7,39,198.80 -
E 8 MARBLE & GRANITE WORK 1,22,017.71 -
F 9 WOOD, WPC & uPVC WORK 4,40,504.77 62,775.99
G 10 STEEL WORK 78,785.68 -
H 11 FLOORING WORK 3,58,829.32 -
I 12 ROOFING WORKS
J 13 FINISHING WORK 7,78,623.05 -
K 21 ALUMINIUM WORK 6,181.28 -
L 22 WATER PROOFING 3,10,808.70 -
GRAND TOTAL 65,12,355
GRAND TOTAL 65,12,355
Digitally signed by PRIYA
BILL OF QUANTITYFOR PRINCIPAL QUARTER (G+0)
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
A 2.00 EARTH WORKS
1 2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over
areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting
out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by
Engineer-in-charge.
i 2.6.1 All kinds of soils Cum 198.58 177.50 35,247.36
2 2.7 Earth work in excavation by mechanical means (Hydralic excavator/manual means)over areas
(exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and
disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by Engineer - in
3 2.10 Excavating trenches of required width for pipes, cables, etc. including excavation for sockets,
and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the
excavated soil, and then returning the soil as required, in layers not exc
a 2.10.1 All kinds of soil.
i 2.10.1.2 Pipes, cables, etc. exceeding 80mm dia but not exceeding 300mm dia. Metre 30.00 352.15 10,564.50
4 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc.
in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and
watering, lead up to 50 m and lift upto 1.5 m.
5 2.26. Extra for every additional lift of 1.5 m or part thereof in excavation /
banking excavated or stacked materials.
5.2 2.26.2 Ordinary or hard rock Cum 4.36 227.40 990.55
6 2.27 Supplying and filling in plinth with sand under floors, including watering,
ramming, consolidating and dressing complete. Cum 25.39 2123.75 53,911.42
7 2.28 Surface dressing of the ground including removing vegetation and inequalities not exceeding
15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
i 2.28.1 All kinds of soil Sqm 186.00 34.15 6,351.90
8 2.34 Supplying chemical emulsion in sealed containers including delivery as specified
i 2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% Litre 57.46 234.75 13,488.15
9 2.35 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment
(excluding the cost of chemical emulsion) :
i 2.35.1.1 Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres /
sqm of the vertical surface of the substructure to a depth of 300mm including excavation
channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with
1% concentration
a) 2.35.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm
apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement
: 2 Coarse sand) to match the existing floor:
i 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration Sqm 38.40 310.05 11,905.92
TOTAL (Carried Over to Summary of Civil Works) 1,79,036.27 0.00
B 4.00 CONCRETE WORKS
1 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of
centering and shuttering - All work up to plinth level :
a 4.1.6 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone
aggregate 40 mm nominal size derived from natural sources) Cum 17.80 7178.75 1,27,790.70
b 4.1.8 1 :4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from
natural sources : 8 graded stone aggregate 40 mm nominal
size derived from natural sources) Cum 4.86 6812.00 33,106.32
2 4.3 Centering and shuttering including strutting, propping etc. and removal of form work for :
i 4.3.1 Foundations, footings, bases for columns. Sqm 10.80 392.15 4,235.22
3 4.2 Providing and laying cement concrete in retaining walls, return walls,
walls (any thickness) including attached pilasters, columns, piers,
abutments, pillars, posts, struts, buttresses, string or lacing courses,
parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,
sunken floor etc., up to floor five level, excluding the cost of centering,
shuttering and finishing:
3.1 4.2.5 1 :3:6 (1 cement : 3 coarse sand (zone-Ill) derived from
natural sources : 6 graded stone aggregate 20 mm nominal
size derived from natural sources) Cum 2.00 9311.40 18,622.80
Digitally signed by PRIYA
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
4 4.11 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2
coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm
nominal size derived from natural sources).
5 4.12 Extra for providing and mixing water proofing material in cement concrete work in doses by Per 50 kg
weight of cement as per manufacturer's specification. cement 9.00 18.15 163.35
6 4.13 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved
quality using 1.7kg per square metre on damp proof course after cleaning the surface with
brushes and finally with a piece of cloth lightly soaked in kerosene oil.
7 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand
(zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick
ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand,
including necessary excavation, levelling & dressing & finishing the top smooth.
TOTAL (Carried Over to Summary of Civil Works) 2,32,736.82 0.00
C 5.00 REINFORCED CEMENT CONCRETE WORK
1 5.9 Centering and shuttering including strutting, propping etc. and removal of form for :
a 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete. Sqm 96.90 392.15 37,999.34
b 5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
c 5.9.3 Suspended floors, roofs, landings, balconies and access platform. Sqm 184.50 927.25 1,71,077.63
d 5.9.4 Shelves (Cast in situ) Sqm 14.78 927.25 13,700.58
e 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers Sqm 316.29 736.40 2,32,916.32
f 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts. Sqm 98.88 961.30 95,053.34
g 5.9.7 Stairs, (excluding landings) except spiral-staircases. Sqm 0.00 764.95 0.00
i 5.9.16 Edges of slabs and breaks in floors and walls
j 5.9.19 Weather shade, Chajjas, corbels etc., including edges. Sqm 13.32 951.10 12,668.65
2 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete upto plinth level.
i 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg 5684.28 107.85 6,13,049.06
3 5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete above plinth level.
i 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg 7967.15 107.85 8,59,256.88
4 5.33.1 Providing and laying in position ready mixed or site batched design mix cement concrete for
reinforced cement concrete work; using coarse aggregate and fine aggregate derived from
natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in
recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to
improve durability and workability without impairing strength; including pumping of concrete to
site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,
finishing and reinforcement as per direction of the engineer-in-charge; for the following grades
of concrete. Note: Extra cement up to 10% of the minimum specified cement content in
design mix shall be payable separately. In case the cement content in design mix is more than
110% of the specified minimum cement content, the contractor shall have discretion to either
re-design the mix or bear the cost of extra cement.
a) 5.33.1 All works upto plinth level.
i 5.33.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum Cum 37.02 9504.75 3,51,859.90
b) 5.33.2 All works above plinth level upto floor V level.
i 5.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum Cum 48.94 9860.40 4,82,563.07
5 5.30 Add for plaster drip course/ groove in plastered surface or moulding to
R.C.C. projections. metre 150.20 78.40 11,775.68
TOTAL (Carried Over to Summary of Civil Works) 28,96,936.06 0.00
D 6.00 BRICK WORK
1 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in
foundation and plinth in:
i 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 20.43 7132.25 1,45,731.53
2 6.32 Brick work with clay flyash F.P.S. (non modular) brick of class designation
7.5 in superstructure above plinth level up to floor five level in :
i 6.32.2 Cement mortar 1 :6 (1 cement : 6 coarse sand) Cum 50.84 9095.05 4,62,393.78
3 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks
of class designation 7.5 in superstructure above plinth level up to floor
3.1 6.13.2 Cement mortar 1 :4 (1 cement :4 coarse sand) Sqm 106.69 1123.80 1,19,892.88
4 6.15 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of
half brick masonry. Sqm 106.69 104.80 11,180.61
Digitally signed by PRIYA
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
TOTAL (Carried Over to Summary of Civil Works) 7,39,198.80 0.00
E 8.00 MARBLE & GRANITE WORK
1 8.2 Providing and fixing 18mm thick gang saw cut ( premoulded and prepolished) machine cut for
kitchen platforms, vanity counters, window sills , facias and similar locations of required size
of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1
cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment,
epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss
finish etc. complete at all levels.
b) 8.2.2 Granite of any colour and shade
8.2.2.2 Area of slab over 0.50 sqm Sqm 5.03 5136.30 25,809.91
2 8.3.2 Providing edge moulding to 18 mm thick marble stone counters, Vanities
etc., including machine polishing to edge to give high gloss finish etc.
complete as per design approved by Engineer-in-Charge. (Granite work) metre 7.03 510.95 3,589.42
3 8.4 Extra for fixing marble /granite stone, over and above corresponding
basic item, in facia and drops of width upto 150 mm with epoxy resin
based adhesive, including cleaning etc. complete. metre 7.03 568.55 3,994.06
1 8.5 Extra for providing opening of required size & shape for wash basin/
kitchen sink in kitchen platform, vanity counter and similar location in
marble/ Granite/ stone work, including necessary holes for pillar taps etc.
including moulding, rubbing and polishing of cut edges etc. complete. Each 2.00 978.70 1,957.40
4 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to
be specified by the manufacturer), of approved make, in all colours, shades except burgundy,
bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps
and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and
jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed
with pigment of matching shade complete.
TOTAL (Carried Over to Summary of Civil Works) 1,22,017.71 0.00
F 9.00 WOOD, WPC & uPVC WORK
1 9.21.1 Providing and fixing ISi marked flush door shutters conforming to IS :
2202 (Part I) non-decorative type, core of block board construction
with frame of 1st class hard wood and well matched commercial 3 ply
veneering with vertical grains or cross bands and face veneers on both
faces of shutters: (35 mm thick including ISi marked Stainless Steel butt hingesn with
necessary screws) Sqm 6.30 2392.65 15,073.70
2 9.127.2 Providing & Fixing decorative high pressure laminated sheet of plain
I wood grain in gloss / matt/ suede finish with high density protective
surface layer and reverse side of adhesive bonding quality conforming to
IS : 2046 Type S, including cost of adhesive of approved quality. (1.0 mm thick)
3 9.23 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all
edges of flush door shutters (over all area of door shutter to be measured).
4 9.24.1 Extra for providing vision panel not exceeding 0.1 sqm in all type of
flush doors (cost of glass excluded) (overall area of door shutter to be
measured): Rectangular or square
5 9.26 Extra for cutting rebate in flush door shutters (Total area of the shutter to
be measured). Sqm 6.30 106.70 672.21
6 9.70.2 Providing and fixing IS : 12817 marked stainless steel butt hinges with
stainless steel screws etc. complete : 100X58X1.90 mm
7 26.86 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid
door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer
of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/
rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)
fabricated with miter joints after applying PVC solvent cement and screwed with full body
threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw
withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58
N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A
category with property of being termite/borer proof, water/moisture proof and fire retardant
and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length
complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners
shall be paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance
in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions
on plus side shall be acceptable but no extra payment on this account shall be made.
Digitally signed by PRIYA
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
8 26.87 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid
plain flush door shutter of required size comprising of virgin polymer of K value 58-60
(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat
husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum
density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge),
minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance
to spread of flame of Class A category with property of being termite/ borer proof,
water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required
size with necessary full body threaded star headed counter sunk S.S screws, all as per
direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws
shall be paid separately)
9 9.46.2 Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with
two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc.,
wherever necessary complete : 20 mm dia 30.95 30.95 393.25 12,171.09
10 9.48.2 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats,
square or round bars etc. including priming coat with approved steel primer all complete.Fixed
to openings /wooden frames with rawl plugs screws etc. Kg 271.80 238.35 64,783.53
11 9.96.2 Providing and fixing aluminium sliding door bolts, ISi marked anodised
(anodic coating not less than grade AC 10 as per IS : 1868), transparent
or dyed to required colour or shade, with nuts and screws etc. complete : (250x16 mm) Each 15.00 260.60 3,909.00
12 9.97 Providing and fixing aluminium tower bolts, ISi marked, anodised (anodic
coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed
to required colour or shade, with necessary screws etc. complete :
13 9.103 Providing and fixing bright finished brass 100 mm mortice latch and lock,
ISi marked, with six levers and a pair of anodised (anodic coating not less
than grade AC 10 as per IS : 1868) aluminium lever handles of approved
quality with necessary screws etc. complete. Each 6.00 868.95 5,213.70
14 9.82 Providing and fixing bright finished brass hanging type floor door stopper
with necessary screws, etc. complete. Each 20.00 121.65 2,433.00
15 9.165 Providing and fixing bright /matt finished Stainless Steel handles of
approved quality & make with necessary screws etc all complete.
16 9.84 Providing and fixing aluminium extruded section body tubular type
universal hydraulic door closer (having brand logo with ISi, IS : 3564,
embossed on the body, door weight upto 36 kg to 80 kg and door width
from 701 mm to 1000 mm), with double speed adjustment with necessary
accessories and screws etc. complete. Each 1.00 983.15 983.15
17 9.135 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory
windows using wire gauge with average width of aperture 1.4 mm in both directions with wire
of dia. 0.50 mm all complete.
17.1 9.135.2 With 12 mm mild steel U beading Sqm 9.66 1228.00 11,862.48
18.00 9.147A Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead
free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded
profiles having minimum wall thickness of 1. 70 mm for Series R 1 and R2 profiles and 2.10
mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape,
colour and design duly reinforced with galvanized mild steel section
made of required shape & size as per CPWD Specification, uPVC extruded glazing beads,
interlocks and lnline sash adaptor (where ever required) of appropriate dimension, EPDM
gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head,
comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS
1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc.
Profile of frame, sash & mullion (if required) shall be mitred cut and fusion
welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing
hardware and drainage of water etc. After fixing frame the gap between frame and adjacent
finished wall shall be filled with weather proof silicon sealant over backer rod of approved size
and quality, all complete as per approved drawing conforming to CPWD specification &
direction of Engineer-in-Charge. Section of steel reinforcement and cross sections
of uPVC profiles to be as per design approved by Engineer-in-Charge.
Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high
performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231
shall be paid separately.
Note:- Structural design proof checked from a Government Engineering Institute, to be
provided by the manufacturer for
(i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3
(ii) Sites with structure height more than 20m for all wind speeds
Digitally signed by PRIYA
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
18.1 9.14 7 .A 1 Two track two panels sliding window with Aluminium channel
for roller track, wool pile, nylon rollers with SS 304 body.
18.2 9.147.A1.1 Using R2 series with frame (40 mm & above)
x (40 mm & above) & sash (25 mm & above)
x (50 mm & above) with zinc alloy (zamak)
powder coated touch locks with hook (Height
18.3 9.147.A4 Three track three panels sliding window with two glazed
& one wire mesh panels with Aluminium channel for roller
track, wool pile, nylon rollers with SS 304 body.
18.4 9.147.A4.1 Using R2 series with frame (70 mm & above) x
(40 mm & above) & both glazed and fly screen Sqm 16.92 10993.55 1,86,010.87
Fixed mm & ventilator
window/ above) x (50 mm &mullion/
without above) transom. Using R1 series with frame (33 mm &
above) x (35 mm & above). (Height upto 0.90 metre) Sqm 2.16 8247.25 17,814.06
19.0 MR-1 Providing and installing SGG Evolite Clear (ET 150) Single Glazed Unit (SGU), comprising 6
mm thick coated glass with coating on Face 2, having a light transmission of 50%, external
light reflection of 13%, internal light reflection of 11%, Solar Heat Gain Coefficient (SHGC) of
0.50 and U-value of 5.0 W/m²K as per EN 673, complete with all necessary glazing
accessories, compatible sealants, labour, handling, transportation and installation as per
approved drawings and manufacturer's specifications.
20 9.131.1 Providing and fixing factory made shutters of Pre-laminated particle
board flat pressed three layer or graded wood particle board with one
side decorative finish and other side balancing lamination conforming
to IS: 12823 Grade I Type 11, of approved design, and edges sealed with
water resistant paint and lipped with aluminium 'U' type edge beading
all- round the shutter, including fixing with angle cleat, grip strip, cadmium
plated steel screws, including fixing of aluminium hinges 100x63x4 mm
etc. complete as per architectural drawing and direction of Engineer-inCharge
(Cost of 'U' beading and hinges will be paid for separately).
19 9.167 Providing and fixing 6 mm thick both sides Pre-laminated cement
bonded wood particle board as per IS : 15786:2008 of approved brand
and shade with suitable full threaded steel screws etc. on the backing of
racks, drawer, cupboard, kitchen cabinet under kitchen counter etc. all
complete as per direction of Engineer-in-charge.
20 9.170.1 Providing and fixing stainless steel fancy handle of approved make fixed
with SS screws etc. complete as per direction of Engineer-in-charge. (200mm)
TOTAL (Carried Over to Summary of Civil Works) 4,40,504.77 62,775.99
G 10.00 STEEL WORK
1 10.3 Providing and fixing in position collapsible steel shutters with vertical
channels 20x1 0x2 mm and braced with flat iron diagonals 20x5 mm
size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia
steel pulleys, complete with bolts, nuts, locking arrangement, stoppers,
handles, including applying a priming coat of approved steel primer. Sqm 0.00 11439.60 0.00
2 10.15.1 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with
rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and
grinded finish, with profiles of required size, including fixing of necessary butt hinges and
screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10
cm long embedded in cement concrete block 15x10x10 cm of C.C. 1 :3:6 (1 Cement : 3
coarse sand: 6 graded stone aggregate 20 mm nominal size)
3 10.18 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of
internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface
hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by
means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of
12 mm dia M.S. bar bent to shape as per standard drawing. Each 12.00 220.65 2,647.80
4 10.25 Steel work welded in built up sections/ framed work, including cutting,
hoisting, fixing in position and applying a priming coat of approved steel
primer using structural steel etc. as required.
a 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works KG 221.00 172.60 38,144.60
5 10.27 Providing and fixing carbon steel galvanised ( minimum coating 5 micron)
dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480
N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6
grade sleeve, including drilling of hole in frame , concrete/ masonry, etc.
as per direction of Engineer-in-charge.
TOTAL (Carried Over to Summary of Civil Works) 78,785.68 0.00
H 11.00 FLOORING WORK
Digitally signed by PRIYA
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
1 DSR 11.41A Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the
manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of
approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar
1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including
grouting the joints with white cement and matching pigments etc. The tiles must be cut with
the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier,
wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles
1.1 11.41A.1.3 Double charge vitrified tile polished finish of size (Size of Tile 600 x 1200 mm)
1.2 11.41A.3.1 Glazed Vitrified tiles MatUAntiskid finish of size (Size of Tile 600 x 600 mm)
2 11.48 Grouting the joints of flooring tiles having joints of 3 mm width, using
epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10
kg of hardener and 0.20 kg of resin per kg), including filling / grouting and
finishing complete as per direction of Engineer-in-charge.
3 11.55 Providing and laying flamed finish Granite stone flooring in required
design and patterns, in linear as well as curvilinear portions of the building all complete as per
the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of
cement mortar 1 :4 (1 cement: 4 coarse sand) laid and jointed with cement slurry and pointing
with white cement slurry admixed with pigment of matching shade including rubbing, curing
and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
3.1 11.55.1 Flamed finish granite stone slab Jet Black, Cherry Red, Elite
Brown, Cat Eye or equivalent. Sqm 13.73 3186.70 43,765.34
4 11.56 Providing and laying Polished Granite stone flooring in required design and patterns, in linear
as well as curvilinear portions of the building all complete as per the architectural drawings
with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1
cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement
slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all
complete as specified and as directed by the Engineer-in-Charge.
4 11.56.1 Polished Granite stone slab jet black,cherry Red ,Elite Brown,Cat Eye or equivalent sqm 4.43 4481.30 19,829.75
TOTAL (Carried Over to Summary of Civil Works) 3,58,829.32 0.00
I 12.00 ROOFING WORKS
1 12.21 Providing and laying gola 75x75mm in cement concrete M15 grade including finishing with
cement mortar 1:3 (1 cement : 3 fine sand) as per standard design in 75x75 mm deep chase.
2 12.55 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm
x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70
and initial emittance> 0.75 on waterproof and sloped surface of terrace,
laid on 20 mm thick cement sand mortar in the ratio of 1 :4 (1 cement : 4
coarse sand) and grouting the joints with mix of white cement & marble
powder in ratio of 1 :1, including rubbing and polishing of the surface upto
3 cuts complete, including providing skirting upto 150 mm height along
the parapet walls in the same manner. Sqm 167 1703.95 2,84,559.65
TOTAL (Carried Over to Summary of Civil Works) 3,05,920.15 0.00
J 13 FINISHING WORK
1 13.4 12 mm cement plaster of mix :
2 13.5 15 mm cement plaster on rough side of single or half brick wall of mix:
3 13.16 6 mm cement plaster of mix :
4 13.21 Extra for providing and mixing water proofing material in cement plaster work in proportion per bag of
recommended by the manufacturers. 50KG
5 13.26 Providing and applying plaster of paris putty of 2 mm thickness over
plastered surface to prepare the surface even and smooth complete. Sqm 711.73 262.70 1,86,971.95
6 13.83.2 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile
Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture,
including applying additional coats wherever required to achieve even shade and colour. Two
Digitally signed by PRIYA
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
7 13.45.1 Finishing walls with textured exterior paint of required shade :
New work (Two or more coats applied @ 3.28 ltr/10 sqm)
over and including priming coat of exterior primer applied @
8 13.47 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required
i 13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of
exterior primer applied @ 2.20 kg/10 sqm) Sqm 211.97 171.10 36,267.72
9 13.50 Applying priming coat :
ii 13.50.3 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on
steel galvanised iron/ steel works Sqm 45.92 67.40 3,094.84
10 13.62 Painting with synthetic enamel paint of approved brand and manufacture of required colour to
give an even shade :
i 13.62.1 Two or more coats on new work over an under coat of suitable
shade with ordinary paint of approved brand and manufacture Sqm 45.92 226.25 10,388.83
11 13.68.1 French spirit polishing : Two or more coats on new works including a coat of wood filler Sqm 64.76 446.25 28,900.94
12 MR-6 Providing and fixing 24 gauge Chicken Wire mesh in junction of block work & RCC works at
corner/wall surface as per direction of Engineer-In-Charge. Sqm Rate only 266.86
TOTAL (Carried Over to Summary of Civil Works) 7,78,623.05 0.00
K 21.00 ALUMINIUM WORK
1 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with
extruded built up standard tubular sections/appropriate Z sections and other sections of
approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with
fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,
at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be
smooth, rust free, straight, mitred and jointed echanically wherever required including cleat
angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all
complete as per architectural drawings and the directions of Engineer-in-charge. Glazing and
paneling to be paid for separately) :
a) 21.1.1 For fixed portion.
i 21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) KG 5.00 530.90 2,654.50
b 21.1.2 For shutters of doors, windows & ventilators including
providing and fixing hinges/ pivots and making provision
for fixing of fittings wherever required including the cost of
EPDM rubber / neoprene gasket required (Fittings shall be
paid for separately)
1 21.1.2.2 Powder coated aluminium (minimum
thickness of powder coating 50 micron) KG 2.00 634.45 1,268.90
2 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc.
with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the
directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic
i 21.3.2 With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
TOTAL (Carried Over to Summary of Civil Works) 6,181.28 0.00
L 22.00 WATER PROOFING
Digitally signed by PRIYA
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. RATE DSR AMT. NSOR AMT.
1 22.7 Providing and laying integral cement based water proofing treatment
including preparation of surface as required for treatment of roofs,
balconies, terraces etc consisting of following operations:
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement
admixed with water proofing compound conforming to IS. 2645 and
approved by Engineer-in-charge over the RCC slab including adjoining
walls upto 300 mm height including cleaning the surface before treatment.
(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm
to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse
sand) admixed with water proofing compound conforming to IS : 2645
and approved by Engineer-in-charge over 20 mm thick layer of cement
mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-in-charge
to required slope and treating similarly the adjoining walls upto 300 mm
height including rounding of junctions of walls and slabs.
(c) After two days of proper curing applying a second coat of cement slurry
using 2.75 kg/ sqm of cement admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge.
(d) Finishing the surface with 20 mm thick jointless cement mortar of mix
1:4 (1 cement :4 coarse sand) admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge including
laying glass fibre cloth of approved quality in top layer of plaster and
finally finishing the surface with trowel with neat cement slurry and making
pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded
with water for a minimum
period of two weeks for curing and for final test. “All above operations to be
done in order and as directed and specified by the Engineer-in-Charge”:
1.01 22.7.1 With average thickness of 120 mm and minimum thickness
TOTAL (Carried Over to Summary of Civil Works) 3,10,808.70 0.00
ALL SUB-HEAD TOTAL 64,49,578.59 62,775.99
GRAND TOTAL 65,12,355
GRAND TOTAL 65,12,355
Digitally signed by PRIYA
PROJECT: PROPOSED KENDRIYA VIDYALAYA CAMPUS AT BARKATHA, DIST.- HAZARIBAGH, JHARKHAND
PRINCIPAL QUARTER BUILDING (GF)
DETAILED ESTIMATE OF INTERNAL PLUMBING
S.No. DSR -2023 / NS Description Unit Qty. Rate (Rs.) Amt. as per DSR
Sub- Head - ( I ), Sanitary Fixture & CP Fittings
1 DSR-17.1 Providing and fixing water closet squatting pan (Indian type
W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low
fixtures complete, including cutting and making good the walls
andlevel white P.V.C. flushing cistern, including flush pipe, with
manually controlled device (handle lever) conforming to IS :
7231, with all fittings and floors wherever required :
DSR-17.1.1 White Vitreous china Orissa pattern W.C. pan of size
580x440 mm with integral type foot rests Each 1 6767.4 6,767.40
2 DSR-17.3 Providing and fixing white vitreous china pedestal type water
closet (European type) with seat and lid, 10 litre low level white
vitreous china flushing cistern & C.P. flush bend with fittings &
C.I.brackets, 40 mm flush bend, overflow arrangement with
specials of standard make and mosquito proof coupling of
approved municipal design complete, including painting of
fittings and brackets, cutting and making good the walls and
floors wherever required :
DSR-17.3.1 W.C. pan with ISI marked white solid plastic seat and lid Each 3 8006.6 24,019.80
3 DSR-17.7A Providing and fixing wash basin with C.I. brackets, 15 mm dia CP
Brass single hole basin mixer of approved quality and make,
including painting of fittings and brackets, cutting and making
good the walls wherever required:-
(a) White Vitreous China Wash basin size 550x400 mm
with a 15 mm CP Brass single hole basin mixer Each 4 3960.55 15,842.20
4 DSR/17.10 Providing and fixing Stainless Steel A ISi 304 (18/8) kitchen sink
as per IS: 13983 with C.I. brackets and stainless steel plug 40
mm, including painting of fittings and brackets, cutting and
making good the walls wherever required :
DSR/17.10.1 Kitchen sink with drain board
DSR/17.10.2 Kitchen sink without drain board
DSR/17.10.1.1 610x510 mm bowl depth 200 mm Each 1 4940.8 4,940.80
5 DSR-18.22 Providing and fixing C.P. brass shower rose with 15 or 20 mm
DSR-18.22.1 150 mm diameter Each 4 222.35 889.40
6 DSR-17.31 Providing and fixing 600x450 mm beveled edge mirror of
superior glass (of approved quality) complete with 6 mm thick
hard board ground fixed to wooden cleats with C.P. brass screws
and washers complete. Each 4 1607.95 6,431.80
7 DSR-17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm
long, 200 mm wide with minimum distances of 37 mm from wall
face with concealed fittings arrangement of approved quality
and colour,weighing not less than 88 gms.
8 DSR-17.73 Providing and fixing PTMT towel rail complete with brackets
fixed to wooden cleats with CP brass screws with concealed
fittings arrangement of approved quality and colour.
DSR-17.73.2 600 mm long towel rail with total length of 645 mm, width
78 mm and effective height of 88 mm, weighing not less
9 DSR-18.65 Providing and fixing PTMT soap Dish Holder having length of
138mm,breadth 102mm, height of 75mm with concealed fitting
arrangements,weighing not less than 106 gms.
10 DSR-17.71 Providing and fixing PTMT liquid soap container 109 mm
wide,125 mm high and 112 mm distance from wall of standard
shape with bracket of the same materials with snap fittings of
approved quality and colour, weighing not less than 105 gms.
11 DSR/17.22B Providing and fixing CP Brass Single lever telephonic wall mixer
of quality & make as approved by Engineer in charge.
Digitally signed Page 1 of 4
S.No. DSR -2023 / NS Description Unit Qty. Rate (Rs.) Amt. as per DSR
(a) 15 mm nominal dia Each 4 6940.75 27,763.00
12 DSR/17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin
including P.V.C. waste fittings complete.
DSR/17.28.2 Flexible pipe
13 DSR/17.69 Providing and fixing PTMT Waste Coupling for wash basin and
sink, of approved quality and colour.
DSR/17.69.1 Waste coupling 31 mm dia of 79 mm length and 62mm breadth
weighing not less than 45 gms Each 4 115.3 461.20
DSR/17.69.2 Waste coupling 38 mm dia of 83 mm length and 77mm breadth,
weighing not less than 60 gms Each 2 122.40 244.80
DSR/17.70 Providing and fixing PTMT Bottle Trap for Wash basin and sink.
DSR/17.70.1 Bottle trap 31mm single piece moulded with height of 270 mm,
effective length of tail pipe 260 mm from the centre of the
waste coupling, 77 mm breadth with 25 mm minimum water
seal, weighing not less than 260 gms. Each 4 367.1 1,468.40
DSR/17.70.2 Bottle trap 38 mm single piece moulded with height of 270 mm,
effective length of tail pipe 260 mm from the centre of the
waste coupling, 77 mm breadth with 25 mm minimum water
seal, weighing not less than 263 gms. Each 2 0.00 -
15 DSR/18.49 Providing and fixing C.P. brass bib cock of approved quality
conforming to IS:8931 :
DSR/18.49.1 15 mm nominal bore Each 7 506.8 3,547.60
DSR/18.50 Providing and fixing C.P. brass long nose bib cock of approved
quality conforming to IS standards and weighing not less than
DSR/18.50.1 15 mm nominal bore Each 2 820.7 1,641.40
16 DSR/18.53 Providing and fixing C.P. brass angle valve for basin mixer and
geyser points of approved quality conforming to IS:8931
DSR/18.53.1 15 mm nominal bore Each 7 574.3 4,020.10
17 NS Providing, fixing, testing and commissioning of heavy duty chrome
plated brass health faucet conforming to relevant IS/CPWD
specifications, comprising trigger operated hand spray, SS braided
flexible hose of 1.2 m length, wall bracket, 15 mm CP brass angle
valve with wall flange, complete with all accessories, connection to
water supply line, cutting/chasing, making good the wall and
testing complete in all respects.
Approved Make: Jaquar / Hindware / Cera / Kohler / Parryware /
Equivalent approved.
Sub- Head - ( II ), Soil, Waste, Vent & Rain Water pipe
1 MR Supply fixing and testing UPVC SWR pipe confirming to IS:13592
for waste connection from wash basin and pantry sink to floor
trap or thermosyphonage pipe with solvent cement joints
including all the fittings laid above the fall ceilling connected in
wall etc the shall include wall chiseling making good the same in
cement mortar etc complete include with all necessary support
like GI hangers support GI grip and bolts GI clamp etc in fall
ceilling area as well as supplying and fixing GI slotted angle iron
bracket hangers supports with necessary drilling holes to suit
the insertion of pipe clamps deburring brick work concrete
supports etc as per detailed drawing for supporting soil waste
and rain water pipes and water supply pipes in shaft with
suitable GI clamps GI bolts anchor nuts and washers fixed on
shaft walls, outer walls etc.
2 MR Providing and fixing M.S. holder bat clamps of approved design
including cost of cutting holes and making good the walls etc.
Digitally signed Page 2 of 4
S.No. DSR -2023 / NS Description Unit Qty. Rate (Rs.) Amt. as per DSR
3 MR Providing fixing and testing UPVC SWR plain ring type 90 Deg
Bend with door IS:14735
4 MR Providing fixing and testing UPVC SWR plain ring type 45 Deg
5 MR Providing fixing and testing UPVC SWR plain Single Y Branch
with Door type fitting IS:14735
6 MR Providing fixing and testing UPVC SWR plain Reducing Single Y
Branch Door type fitting IS:14735
7 MR Providing fixing and testing UPVC SWR plain Tee Branch with
Door type fitting IS:14735
8 MR Providing and fixing and testing UPVC single floor trap with all
necessary UPVC pipes connection extension pipe and reducing
tee for water pipe connections from toilet and wash area.
9 MR Providing and fixing 75 mm dia, 3 mm thick Stainless steel
grating with frame for floor traps or drains of required pattern
including cutting and making good the floors complete.
10 DSR /4.1 Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering - All work
up to plinth level:
DSR /4.1.3 1:2:4 (1 cement :2 coarse sand: 4 hard stone aggregate 20mm
and down gauge). Cum 0.35 7878.5 2,757.48
11 DSR/12.22 Making khurras 45x45 cm with average minimum thickness of 5
cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m
x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1
cement : 3 coarse sand) and a coat of neat cement, rounding the
edges and making and finishing the outlet complete.
12 DSR /12.41 Providing and fixing on wall face unplasticised Rigid PVC rain
water pipes conforming to IS : 13592 Type A, including jointing
with seal ring conforming to IS : 5382, leaving 10 mm gap for
thermal expansion, (i) Single socketed pipes.
DSR /12.41.2 110 mm diameter Metre 10 377.4 3,774.00
13 DSR /12.42 Providing and fixing on wall face unplasticised - PVC moulded
fittings/ accessories for unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for thermal
DSR /12.42.1 Coupler
DSR /12.42.3 Single tee with door
DSR /12.42.5 Bend 87.5
14 DSR /12.43 Providing and fixing unplasticised -PVC pipe clips of approved
design to unplasticised - PVC rain water pipes by means of
50x50x50 mm hard wood plugs, screwed with M.S. screws of
required length, including cutting brick work and fixing in
cement mortar 1:4 (1 cement : 4 coarse sand) and making good
the wall etc. complete.
15 DSR /12.44 Providing and fixing to the inlet mouth of rain water pipe cast
iron grating 15 cm diameter and weighing not less than 440
grams. Each 2 54.7 109.40
16 DSR-18.58 Providing and fixing PTMT grating of approved quality and
Digitally signed Page 3 of 4
S.No. DSR -2023 / NS Description Unit Qty. Rate (Rs.) Amt. as per DSR
18.58.1 Circular type
18.58.1.1 100 mm nominal dia Each 8 37.6 300.80
Sub- Head - ( III ), Internal Water Supply
1 DSR /18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all
CPVC plain & brass threaded fittings, including fixing the pipe
with clamps at 1.00 m spacing. This includes jointing of pipes &
fittings with one step CPVC solvent cement and testing of joints
complete as per direction of Engineer in Charge.
Internal work - Exposed on wall
DSR /18.7.1 15 mm nominal outer dia Pipes Metre 286.8 -
DSR /18.7.2 20 mm nominal outer dia Pipes Metre 335 -
DSR /18.7.3 25 mm nominal outer dia Pipes Metre 18 401.55 7,227.90
DSR /18.7.4 32 mm nominal outer dia Pipes Metre 518.55 -
DSR /18.7.5 40 mm nominal outer dia Pipes Metre 702.95 -
DSR /18.7.6 50 mm nominal outer dia Pipes Metre 934.15 -
2 DSR /18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all
CPVC plain & brass threaded fittings, i/c fixing the pipe with
clamps at 1.00 m spacing. This includes jointing of pipes &
fittings with one step CPVC solvent cement and the cost of
cutting chases and making good the same including testing of
joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the
DSR/18.8.1 15 mm nominal outer dia Pipes Metre 497.8 -
DSR/18.8.2 20 mm nominal outer dia Pipes Metre 20 537.6 10,752.00
DSR/18.8.3 25 mm nominal outer dia Pipes Metre 20 627.25 12,545.00
DSR/18.8.4 32 mm nominal outer dia Pipes Metre 739.3 -
3 DSR/18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply including all
CPVC plain & brass threaded fittings This includes jointing of
pipes & fittings with one step CPVC solvent cement, trenching,
refilling & testing of joints complete as per direction of Engineer
Pipe running at terrace level
DSR/18.9.6 50 mm nominal inner dia Pipes Metre 30 794.25 23,827.50
DSR/18.9.7 65 mm nominal inner dia Pipes Metre 1674.4 -
DSR /18.9.8 80 mm nominal inner dia Pipes Metre 2166.35 -
DSR /18.9.9 100 mm nominal inner dia Pipes Metre 3271.7 -
DSR /18.9.10 150 mm nominal inner dia Pipes Metre 6822.7 -
4 DSR/18.48 Providing and placing on terrace (at all floor levels) polyethylene Per 1000 11 11,000.00
water storage tank IS: 12701 marked, with cover and suitable litre
locking arrangement and making necessary holes for inlet, outlet
and overflow pipes but without fittings and the base support for
5 MR Providing and fixing forged brass operated ball valve of full flow
of superior quality having minimum working pressure of 16
5.1 25 mm nominal bore Each 4 3262.00 13,048.00
5.2 32 mm nominal bore Each 1 4600.00 4,600.00
Digitally signed Page 4 of 4
SUMMRY OF INTERNAL ESTIMATE (ELEC& ELV) PRINCIPLE BUNGLOW ( G+0) AT KV,
BARKATAHA, HAZARIBAGH
SLNO DESCRIPTION AMOUNT
1 SCHEDULE ITEMS (DSR-2025) (PART-A)
i) TOTAL OF SUB-HEAD :1 3,16,660.00
ii) TOTAL OF SUB-HEAD :2 20,380.00
iii) TOTAL OF SUB-HEAD :3 18,302.00
iv) TOTAL OF SUB-HEAD :4 31,630.00
v) TOTAL OF SUB-HEAD :5 32,856.00
vii) TOTAL OF SUB-HEAD :6 1,19,741.00
viii) TOTAL OF SUB-HEAD :7 2,286.00
TOTAL OF SCHEDULE ITEMS (PART-A) 5,41,855.00
2) TOTAL OF NON SCHEDULE ITEMS (PART-B) 1,32,489.00
TOTAL (SCHEDULE + NON SCHEDULE ITEMS)
Digitally signed by PRIYA
ESTIMATE FOR INTERNAL ELECTRICAL PRINCIPLE BUNGLOW ( G+0) AT KV , BARKATAHA, HAZARIBAGH
Sl. No. Item Description UNIT QTY RATE AMOUNT (DSR) AMOUNT (NON
Code. SCHEDULE
DSR- SCHEDULE ITEMS (DSR-2025) (PART-A)
SUB-HEAD :1_WIRING
1 D.S.R Point Wiring in Medium Class PVC Conduit, with Modular type Switch: Wiring for
1.10 light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/ HFFR PVC
( Page insulated copper conductor single core cable in surface/recessed Medium Class PVC
No.-03) conduit, with modular type switch, modular plate, suitable size of GI box and earthing the
point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc as
2 D.S.R Wiring for light/power plug with 2x4 Sq.mm FRLS/HFFR PVC insulated copper conductor Mtr. 160 373.00 59,680.00
1.12 single core cable in surface/recessed Medium Class PVC conduit along with 1 No. 4 Sq.mm
( Page FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing etc. as
No.-03) required.
3 D.S.R Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of
1.14 FRLS/HFFR PVC insulated copper condcutor, single core cable in surface/ recessed Medium
( Page Class PVC conduit as required.
4 D.S.R Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed
1.18 copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC
( Page conduit as required
5 D.S.R Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE Mtr. 120 54.00 6,480.00
1.18 insulated, shielded with fine tinned copper braid and protected with PVC sheath in the
( Page existing surface/ recessed steel/ PVC conduit as required.
6 D.S.R Supplying and fixing of following sizes of medium class PVC conduit along with accessories
1.21 in surface/recess including cutting the wall and making good the same in case of recessed
( Page conduit as required.
7 D.S.R Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with
1.22 suitable size of phenolic laminated sheet cover in front
( Page including painting etc. as required.
8 D.S.R. Supplying and fixing following modular switch/ socket on the existing modular plate &
1.24 switch box including connections but excluding modular plate etc. as required.
1.24.4 3 pin 5/6A socket outlet Each 10 136.00 1,360
1.24.5 6 pin 15/16 amp socket outlet Each 3 219.00 657
1.24.6 Telephone socket outlet Each 1 168.00 168
1.24.7 TV antenna socket outlet Each 4 168.00 672
1.24.8 Bell push Each 1 159.00 159
9 D.S.R. Supplying and fixing two module stepped type electronic fan regulator on the existing Each 8 402.00 3,216.00
1.25 modular plate switch box including connections but excluding modular plate etc. as
( Page required.
10 D.S.R. Supplying and fixing following size/ modules, GI box along with modular base & cover plate
1.27 for modular switches in recess etc. as required.
11 D.S.R. Supplying and fixing suitable size GI box with modular plate and cover in front on surface Each 7 545.00 3,815.00
1.31 or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A
( Page modular switch, connections etc. as required.
12 D.S.R. Supplying and fixing suitable size GI box with modular plate and cover in front on surface Each 8 659.00 5,272.00
1.32 or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and
( Page 15/16 A modular switch, connections etc. as required.
13 D.S.R. Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block Each 18 104.00 1,872.00
1.33 including connections etc. as required
14 D.S.R. Supplying and fixing brass batten/ angle holder including connection etc. as required. Each 14 154.00 2,156.00
15 D.S.R. Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as Each 1 112.00 112.00
1.38 required.
16 D.S.R. Installation, Testing and Commissioning of exhaust fan in the existing opening, including
1.50 making good the damage, connection, testing, commissioning etc. as required.
17 D.S.R. Supplying and fixing suitable size GI box with modular plate and cover in front on surface Each 5 757.00 3,785.00
1.56 or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2
( Page nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non
No.-11) residential buildings).
18 D.S.R. Supplying & fixing suitable size GI box with modular plate and cover in front on surface or Each 4 807.00 3,228.00
1.57 in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP
( Page MCB, "C" curve including connections, painting etc. as required.
TOTAL OF SUBHEAD :1 3,16,660.00
SUB-HEAD :2 MCCB,MCB & DB'S
19 D.S.R 2.4 TPN DB :- Supplying and fixing following way, horizontal type three pole and neutral,
( Page sheet steel, MCB distribution board, 415 V, on surface/recess,complete with tinned copper
No.-14) bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including
earthing etc. as required. (But without MCB/RCCB/Isolator).
20 D.S.R MCB:- Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature
2.10 circuit breaker suitable for inductive load of following poles in the existing MCB DB
( Page complete with connections, testing and commissioning etc. as required.
21 D.S.R Supplying and fixing following rating, double pole, single phase and neutral), 240 V,
2.14 residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing
( Page MCB DB complete with connections, testing and commissioning etc. as required.
22 D.S.R Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at Each 1 315.00 315.00
2.21 least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single
( Page red colour on front side as required.
TOTAL OF SUBHEAD :2 20,380.00
SUB-HEAD :3 EARTHING SYSTEM
23 D.S.R. Earthing with G.I. earth plate 600 mm X 600 mm X6 mm thick including accessories, and Each 2 8,351.00 16,702.00
5.4 ( Page providing masonry enclosure with cover plate having locking arrangement and watering
No.-30) pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
24 D.S.R. Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth Mtr 10 160.00 1,600.00
5.9 electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as
( Page required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring
No.-31) washer spaced at 50mm)
TOTAL OF SUBHEAD :3 18,302.00
SUB-HEAD :4 LIGHTNING CONDUCTOR
25 D.S.R. Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. Each 2 609.00 1,218.00
6.1 tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including
( Page holes etc. complete as required.
26 D.S.R. Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for Each 70 148.00 10,360.00
6.6 lightning conductor complete as required.(For horizontal run)
27 D.S.R. Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for Each 12 238.00 2,856.00
6.7 lightning conductor complete as required.(For vertical run)
28 D.S.R. Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, Each 2 140.00 280.00
6.10 with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required
29 D.S.R. Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and Each 2 7,658.00 15,316.00
5.2 ( Page providing masonry enclosure with cover plate having locking arrangement and watering
No.-30) pipe etc. with charcoal/ coke and salt as required.
30 D.S.R. Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth Mtr 10 160.00 1,600.00
5.9 electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as
( Page required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring
No.-31) washer spaced at 50mm)
TOTAL OF SUBHEAD :4 31,630.00
SUB-HEAD :5 LED LIGHT & FAN
Note:- All LED Light fittings LM 79 and LM 80 reports need to be submitted with all
accessories and 50,000.00 hrs shall as burning life. Samples of alltype LED light fixtures
are to be submitted to the Engineering Incharge and each LED Light should have minimum
100lm/W for the approval prior to procurement of light fixtures.
31 D.S.R. LED Down lighter (COB Type) (System lumen efficacy ≥105 < 120 lm/Watt ).
Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter
(Round/ Square/ Rectangular) COB Type of following body material and construction as
per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating
voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C,
internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%
, P.F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should
be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning
Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K
/4000°K/5700°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)
<3, Maximum power consumption should not more than the specified rating and
Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name
Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external
connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core
cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen
efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing
required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as
approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of
aluminium housing such that LED junction temperature shall not rise above 90°C) Powder
coated die cast /Extruded aluminium Body including trim with Aluminium Reflector .
32 D.S.R. LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).
8.9 Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of
( Page following body material and construction as per IS : 10322 with driver (Replaceable) as per
No.-45) the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt,
frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5
KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker
free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of
minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT
3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard DeviationColour
Matching) <3, Maximum power consumption should not more than the specified rating and
Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/
Embossing/ Screen printing on housing. complete in all respect i/c external connections
with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing
etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120
lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per
BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-
Charge as per requirement. (Thermal management: heat sink of aluminium housing such
that LED junction temperature shall not rise above 90°C). Powder coated die cast
/Extruded aluminium Body (Thickness > 1.20 mm)
33 D.S.R. LED Street light fixture, powder coated pressure die cast aluminium body (System lumen
8.12 efficacy ≥105 <120 lm/Watt) (to use as building outer light)
Supplying, installation, Testing & Commissioning of Street light (to be use as Building Outer
Light) LED fixture powder coated pressure die cast aluminium body with driver as per the
requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency
50/60 hz, Operating temp range -5°C to 50°C, internal surge protection of 5 KV L,N,E as
per IEC 61000-4-5,61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over
voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type
I/II/III as per the width of the road and the project requirement., suitable to fit in up to
65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning
Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-
21-11 report,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard
Deviation Colour Matching) <5, Maximum power consumption should not more than the
specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c
external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single
core cable and earthing etc. as required with Minimum 5 year OEM warranty. System
lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing
required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as
approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of
8.12.7 aluminium
25 housing LIGHT
W LED STRRET such that LED junction temperature shall not rise above 90°C). Each 2 1,000.00 2,000.00
34 D.S.R. Brush Less Direct Current (BLDC) Fan without Remote:-
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct
Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium
alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper
winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum
as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less
than 10%, suitable for operation with regulator
for speed control and all remaining accessories including safety pin, nut bolts, washers,
temperature rise=75 0C (max.), insulation resistance more than 2
mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS
374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR,
PVC insulated copper conductor single core cable and earthing etc. as required.
9.2.3 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
TOTAL OF SUBHEAD :5 32,856.00
SUB-HEAD :7 LOW VOLTAGE SYSTEM SCHEDULE ITEMS (DSR-2025)
35 D.S.R. Supplying, Installation, Testing & Commissioning of Analog phones having standard Each 1 1,544.00 1,544.00
38.4 feautres like 16 digit LCD display, 2 way speaker, caller ID and number storage facility etc.
( Page complete as required.
DATA NETWORKING SYSTEM
36 D.S.R.- Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2
39.1 (P. indoor Network Switch having features and specifications etc. as mentioned here under: At
no-.268) least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports
DSR-2025 with non-blocking architecture by having Switching capacity of min. 128 Gbps and packet
forwarding rate of 95Mpps or higher, 16K MAC table. Console Port, USB port, Stacking
support of min. 4 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU
Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD
Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP
Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ,
Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening.
RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR,
Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time
based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client,
LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route,
SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access
ports. Certifications: FCC, CE marked, UL/EN, RoHS and relevant MTCTE{TEC)/BIS
compliance/ certification as applicable, etc. complete as required.
39.1.1 8 port PoE Layer 2 Network Switch with PoE Support of 130W or higher with each copper Each 1 35,091.00 35,091.00
port supporting 802.3at PoE+.
37 D.S.R. Supplying, Installation, Testing and commissioning of small form-Pluggable (SFP) for
39.6 Network Switches. Must be hot Pluggable, RoHS Complaint, etc. complete as required.
39.6.1 1G SFP Single Mode/Multi Mode Each 1 4,211.00 4,211.00
38 D.S.R. Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded (8 Each 1 5,278.00 5,278.00
39.11 oport Loade) Must be of 1U height with clear label holders and white label with the panel.
(Page No.- 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for
274) compliance with ANSI/TIA-568.2-D etc. complete as required.
39 D.S.R. Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should
39.12 have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc.
(Page No.- complete as required.
39.13.1 Copper Patch Cords of length 1m (3ft) Each 2 173.00 346.00
40 D.S.R. Supplying, Installation, Testing and commissioning of CAT6A Copper Information Outlet Each 2 302.00 604.00
39.15 (IO) with face plate of color as per site requirement, should have ETL/UL verification
( Page program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and
No.-275) Components should be from same OEM to maintain compatibility
and interoperability etc. complete as required.
39 D.S.R. Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. Each 2 9.00 18.00
39.16 RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-
(Page No.- 2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required.
40 D.S.R. Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper
39.18 cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable
(Page No.- suitable for high speed data networking application supporting upto 10Gbps over a 100
275) meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for
easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1,
Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC
11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter
should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc.
complete as required.
41 D.S.R. Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring.
39.19 The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following
(Page No.- Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-
277) core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE-
Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage
Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db / km) at Operational
Wavelength 1310 nm and ± 0.22 db / km at Operational Wavelength 1550 nm. type of
fiber should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675. The value for
Mode-filed, Cladding Diameter 9.2 ± 0.4 μm and 125 ± 0.7 μm correspondingly. The
Dispersion value < 3.5 < 18 ps/nm-km and PMD value < 0.2 ps/km and Cable Cutoff
wavelength < 1260 nm i/c splicing & marking etc complete as required.
39.19.1 6 Core Multi Mode Optical Fiber Cable Meter 65 64.00 4,160.00
41 D.S.R. Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable
39.21 saddles for jumper management, suitable to manage both splices and terminations, Pre-
(Page No.- assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal
278) splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber
storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter,
Removable front and rear covers for better access to interior of LIU, Should be Single /
Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws,
and spiral wrap tube etc complete as required.
42 D.S.R. Supplying and fixing Patch Cord of Optical Fiber Multi Mode or Single Mode LC to LC Fiber Each 1 705.00 705.00
39.22 Duplex having high precision ceramic ferrule with good concentricity, Fiber corning single
(Page No.- mode G652D, Cable Type 2mm with Mechanical specification Apex Offset < 50 μm, Fiber
278) Height + 100 nm, End-face radius of Curvature 7mm < R <25mm, Repeatability < 0.2 dB,
(As per correction Slip-1 DSR-568-H E &M- 2025) Working ambient Temperature – 5 0C
to +50 0C, Storage Temperature – 10 0C to +50 0C, Length -- 2meter, Type -- LC-LC
Duplex etc complete as required.
43 D.S.R. Supplying and fixing Outdoor Pole/ Wall mount 6U Rack, IP55, Front Door with Filter, Each 1 22,228.00 22,228.00
39.26 Louver & Unique key Lock. 3 Socket PDU 5Amp - 1 No. Self adhesive thermal foam from
(Page No.- inside. Hood For Air Inlet at front side.1U Cantilever Tray 250mmDepth, Gasket. etc
279) complete as required.
CCTV CAMERA SYSTEM
44 5MP/6MP IP IR DOME CAMERA
D.S.R. Supplying Installation Testing and Commissioning of 5/6MP IP IR Dome Camera having
40.5 followingspecifications and features etc :-
( Page 1)Type of Camera: Dome Camera
No.-286) 2) Image Sensor: 1/2.8" or better progressive Scan CMOS get color image even at night
3) Signal System: PAL/NTSC
4) Minimum Illumination: 0.008Lux@ F1.4, AGC ON, 0 lux with IR or better
5) Imaging: 1/3s to 1/30000s Shutter Support, Auto Gain Control , White Balance- Auto,
Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.
6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded
7) Signal to Noise Ratio: > 50 dB
8) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto
switch, IR Source- Inbuilt IR LED's with effective distance upto 50 Mtrs integrated IR 30
Mtrs for colour view in night.
9) Video Compression (Minimum): H.265 or better, Audio:- G.711U/A, G.711Mu, G.726,
10) Wide Dynamic Range: WDR (120dB or more)
11) Digital Noise Reduction: DNR (2D/3D) On/Off
12) Streaming: Triple streaming, configurable
13) Video Streaming & Frame Rates: Triple streaming configurable Main stream: 5/6MP
@25/30 fps, Sub streams: D1@25/30 fps or better
14) Image Setting: Rotate Mode, saturation,
brightness, contrast, sharpness adjustable through client software or web browser
15) Profile Management: User configuration import, export
16) Security: User Authentication, Water Marking
17) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto
512 GB. It should be supplied with minimum 128GB memory Card.
18) Recording Management: Format SD, overwrite, storage management, video to NAS
device,19) Edge Analytics : Tripwire, Intrusion, Motion Detection
20) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP
conflict detection; memory card state detection; memory space detection
21) Alarm Support: It should have 1/1 Alarm In/ Out Port
22) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external
Mic. and Speaker (As per site requirement) with G.711U/A/ G.711Mu/ AAC/ G.726 audio
23) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP,
PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,
24) System IP Capability:
ONVIF mm fixed lens (as per site requirement) Dome Camera. Each 1 12,800.00 12,800.00
5MP/6MP IP IR BULLET CAMERA
45 D.S.R. Supplying Installation Testing and Commissioning of 5MP/6 MP IP IR Bullet Camera having
40.6 following specifications, type of lens and features etc :-
(Page No.- 1) Type of Camera: Bullet Camera
288) 2) Image Sensor: 1/2.8" or better progressive Scan CMOS get color image even at night
3) Signal System: PAL/NTSC
4) Minimum Illumination: 0.006Lux@ F1.4, AGC ON, 0 lux with IR or better
5) Imaging: 1/3s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light
Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.
6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded
7) Signal to Noise Ratio: > 50 dB
8) Lens Type & Focus: as given below.
9) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto
switch, IR Source- Inbuilt IR LED's with effective distance upto 50 Mtrs integrated IR and
30 Mtrs for colour view in night.
10) Video Compression (Minimum): H.265 or better, Audio:- G.711U/A, G.711Mu, G.726,
11) Wide Dynamic Range: WDR (120dB or more)
12) Digital Noise Reduction: DNR (2D/3D) On/Off
13) Streaming: Triple streaming, configurable
14) Video Streaming & Frame Rates: Triple streaming , configurable Main stream:
5MP/6MP @25/30 fps, Sub streams: D1@25/30 fps or better
15) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable
through client software or web browser
16) Profile Management: User configuration import, export
17) Security: User Authentication, Digital Water Marking
18) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto
512 GB. It should be supplied with minimum 128GB memory Card.
19) Recording Management: Format SD, overwrite, storage management, video to NAS
20) Edge Analytics: Tripwire, Intrusion, Motion Detection
21) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP
conflict detection; memory card state detection; memory space detection
22) Alarm Support: It should have 1/1 Alarm In/ Out Port
23) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external
Mic. and Speaker (As per site requirement) with G.711U/A / G.711Mu/
AAC/ G.726 audio compreesion
24) NetworkIP Protocol:
IR 2.8 to SFTP,
3.6/6/8/12 mm fixed
IPv6, IPv4, lens (as
DNS,RTCP, perRTP,
NTP, site HTTP,
requirement outdoor
HTTPS, SNMP Bullet
46 D.S.R. Supplying and laying of following size DWC HDPE pipe ISI marked along with all
15.15 accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete
(Page No.- with fitting and cutting, jointing etc. in the existing trench, complete as required.
15.15.1 63 mm dia (OD-63 mm & ID-51 mm nominal) Mtr 65 136.00 8,840.00
TOTAL OF SUBHEAD :7 1,19,741.00
TOTAL OF SCHEDULE ITEMS (PART-A)
CIVIL DSR-2023 ITEMS (PART-B)
SUB-HEAD :8 GI PIPE
46 DSR-2025 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with
15.13 G.I. fittings including trenching (75 cm deep)and re-filling etc as
( Page required
TOTAL OF SUBHEAD :8 GI PIPE 2,286.00
TOTAL OF SCHEDULE ITEMS (PART-A) 5,41,855.00
NON SCHEDULE ITEMS (PART-B)
(ELECTRICAL & ELV)
LED LIGHT FIXTURES
47 N.S. Note:- All LED Light fittings LM 79 and LM 80 reports need to be submitted with all
accessories and 50,000.00 hrs shall as burning life. Samples of alltype LED light fixtures
are to be submitted to the Engineering Incharge and each LED Light should have minimum
100lm/W for the approval prior to procurement of light fixtures.
(N.S.-i) Supply of 9W/10W LED Bulb (Luminous Flux- 600lm, CCT-6500K (Cool W 9/10 watt LED Each 14 104.00 1,456.00
Bulb, B22, 6500 Khite), CRI-80, Rated Voltage- 220V/ 240V. Beam Angle- 120 degree
(N.S.-ii) Supply and fixing of 10 W LED Type Bulk Head luminaire (Metal Body) with minimum Each 2 2,375.00 4,750.00
efficency 100lm/w in comprising of pressure die cast housing, acrylic diffuser, IP 66
protection and complete with ectronic driver etc. dirctly on wall or ceiling including
connection with 1.5 Sq. mm, FRLS PVC cu conductor cable etc. as required with lamp
(N.S.iii) Supply, installation, testing and commissioning of 2ft 10W LED Batten delivering an initial Each 5 621.00 3,105.00
system lumen of 1000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W.
The housing should be made of Extruded Aluminium with polycarbonate diffuser. The
operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered
electronic driver with input voltage range of 150 to 270V , PF ≥ 0.9 ,THD ≤ 10%, 50,000
Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have
minimum surge protection of 2.5KV. The luminaire shall be with following certifications:
LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard.
(N.S.-iV) Supply, installation, testing and commissioning of LED 3x8W chandelier light as per Each 1 10,284.00 10,284.00
Architectural drawings with all accessories complete as required.
48 N.S. All Exhaust shall be of minimum 2 years of Warranty. Samples of all Fans are to be
submitted to the Engineer-in- charge for the approval prior to procurement of Exhaust
(i) SITC of 230mm 230V AC single phase,1440RPM Exhaust Fan, double ball bearing (Metal Each 4 2,002.00 8,008.00
Body, metalick blade,- Light Duty) exhaust fan as required.
N.S.I Supply, fitting fixing and testing of 63A/ FP. 10kA, C Series MCB . Each 1 2,738.00 2,738.00
50 (N.S. i) METER PANEL FOR NEW PROPOSED PRINCIPAL QUARTE
Supplying, designing, manufacturing and commissioning in correct alignment position,
effecting proper connection of all incomer and outgoing feeders of Smart Meter Panel ,
unloading at site, shifting to loaction, fitting, fixing and testing of meter Panel, fabricated
out of 2mm thick (14SWG) CRCA sheet steel for Load bearing and 1.6 mm or 16 SWG
Unload Bearing, dust and vermin proof with reinforcement of suitable size iron channel,
size 50mmx50mmx6mm with proper lifting arrangement, (IP-42) fully compartmentalized
cubical type (folded joints construction), wall mounted, totally enclosed, accessories, all
out going feeders protection & meters as required, free floor standing, factory built sheet
steel enclosed extendable panel and suitable for use on 415V, 3 phase, AC Supply, 4 wire,
50 C/S, system having 25 KA fault capacity, housed with incoming and outgoing aluminum
bus bars, interconnection, interlocking between feeders etc. with indicating lamps, push
buttons, necessary accessories, all out going feeders protection & meters as required.
The sheet steel under go minimum 7 tanks treatment followed by finishing of powder
coating of minimum 60 micron thickness, duly compartmentalized having accessories
mounted inside the cubical panel, earthing with 2 Nos. earth studs.
The Smart Energy Meter Panel shall be totally enclosed, completely dust and vermin proof.
Synthetic rubber gaskets (neoprene/DPDM) between all adjacent units and beneath all
covers shall be provided to render the joints dust proof. All doors and covers shall be fully
gasketed and shall be lockable. Doors shall have concealed hinges. All the doors shall be
suitably reinforced by channel to provide rigidity. Panel shall have suitable cable entry from
bottom/Top and suitable arrangement for aluminum cable termination.
The Smart Energy Meter Panel shall be provided with a thermostatically controlled heating
arrangement (200 W) to take care of high humidity conditions. A 6/16A socket with sitch
as service outlet (single phase) and 1 no. 10W LED LAMP with holder shall be provided in
one of the compartments as service outlet in the panel. The complete panel shall be fuse
less type, for control circuits 2A SP MCB's to be used.
For the protection of equipment & feeders, switchgear shall be provided with required O/C
& S/C releases. Selection of switchgear rating shall be made on the basis of load current &
fault withstand capacity.
Panel Builder will provide shop drawing SLD & GA drawing along with BOM with CAT. No. of
each and every components and switch gears of Meter Panel for approval of Consultant or
concirned department. Inspection of the Meter Panel shall be carried out at Panel Builder's
factory by the Consultantor departmental engineers before final delivery for that all
arrangements shall be made by the contractor.
Location :- Near Front Varandha
The Name Plate for each feeder must be in Anodized Aluminium Sheet.
MCCB:- L&K-DSine/ LEGRAND-DPX³/SCHNEIDER-NSX/ SIMENS- 3VJ-3WJ
MCB- C Series 10kA _ Legrand- DX³/Schneider- ACTI-9/Siemens- Beta Guard/ L&K- AU
Make of Smart Energy Meter (Kwh- Meter) :- L&K, Socomo/Secure, HPL.
Name of Panel Bulder:- Name of Panel builders -Name of Panel builders:- EAP Kolkat,
Green Galaxy Kolkata, JMD, Kokar, Ranchi, STEC, SIRDO, BIT, Meshra, Meditiron, SIRDO,
BIT Meshra, Ranchi. Amichand Technology, Jamshedpur.
The panel includes 415V, 100A, 3Ph, 25KA, 50Hz, TPN Electrolytic Aluminium Bus Bar
(E91E) GI Earth Bus with removable glands plates, cable glands at sending and receiving
ends, including connection with outgoing feeders complete in all respects. The electrolytic
Aluminium bus bar as per I:S 5082 of suitable length and insulated by heat shrinkable
sleeves Red, yellow, Blue and Black as R Y B & N. The current density of bus bar shall be
minimum 0.8 A / sq mm. Minimum clearance between live parts / neutral to earth shall be
19 mm. However clearances between terminals at components shall be as per applicable
individual standard for components. Interconnections between the main bus bars and
individual units shall be made using vertical / horizontal Bus Bar to individual MCB shall be
made with 4 & 6 Sq mm FRLS PVC Cu. wire aluminium bus bars of adequate rating. AL.
Bus Bar will be supported on insulators made of non-hygroscopic, non-inflammable
material with tracking index equal to or more than that defined in BIS.
1 Set of Fabrication part of LT Panel & busbar system, with AL. bus bar and
interconnection FRLS cables) in CRCA Sheet Steel enclosure (IP-42) without components.
Name of Panel builders - as per approved make list.
1 Sets Multifunction Meter having LED mete display accuracy Class 1 as per IEC 62053-21,
should have an active RS-485 port, in built RTC, Aux Supply: 44-277Vac/dc. Parameters:
Volts, Amps, PF, THD, F, W, Wh, VA, VAh, Var, Varh, Runhrs, Onhrs Interrupts, THD for
V&I per phase, individual harmonics for V&I upto 15th level complying with IEC61557-12.
Min/Max for eight parameters. Sampling rate: 64 samples per cycle. MAKE- L& K /
SCCHEIDER-EM6400/ Legrand-EDMX3/CX3/PMX
3 Nos. CT of different power as per incomer & out going /5VA -5 class one Epoxy resin cast
CT (3 Nos.)=1 Set.
3 Sets Phase indicating light shall be protected by 2 Amps SP MCB's for incomer &
1 No. 63 A F/P MCCB (25kA) with adjustable thermomagnetc release type with S/C & O/L
protection, and front rotary Handle and spreader links in both ends Cable Size 3.5 C 35
Sq.mm Al,Ar, Cable)
2 nos. 63 FP/10kA/C Serise MCB & 1 nos. 415/Three Phase, 4 Wires 415V 10-60A LCD
Smart Meter energy with optical port and box, Frequency 50Hz, Complying to IP51, with
LCD Display, kWh LED, encrypted STS based token System with RS485 Modbus and
polycarbonate box along with Vending/Server charges per meter per annum with 63A FP
/10 kA MCB including 45 Sq.mm. 3 studs brass terminal. LCD Display Smart Energy
meter in panel. (Note:- Location of kWh Smart Meter shall be out side the Meter Panel as
per the latest Guide lines of SEB, and shall be installed in a Systematic formation and
demarcation with respective Quarter no.)
2 no. 63A/FP/10kA/ C Series MCB (1 no. as spare)
1 no. 415/Three Phase, 4 Wires 415V 10-60A LCD Smart Meter energy Meter with optical
2 nos. 45 Sq.mm. 3 studs brass terminal
Total Cost of Smart Energy Meter Panel of Principal Quarter Set 1 77,803.00 77,803.00
TELEPHONE SOLUTION
51 N.S.I Krone box:-
Providing, fixing, connecting & testing of Krone box (Telephone Tag Block) in a
thermoplastic, IP 65 (weather proof) enclosure, internally embedded gasket, anti corrosive,
insulated and shock proof with provision for cable through IP 65 glands complete in all
i) 5 pair Tag Block (krone Box) (136 mm x 253 mm x 115 mm) Each 1 1,048.00 1,048.00
ii) Providing, laying, connecting, testing & commissioning of telephone 5 Pair armoured Mtr 65 333.00 21,645.00
cables of conductor size 0.5 sq.mm. high conductivity Solid Annealed Bare tinned Copper
Telphone cable (with ferrule) with high density Polythene insulation, Paired, Polyester and
seathed with high Oxygen Index, Fire Retradant, PVC Compound, Gey Outer Sheath
generally confirming ITD Specification, laid on existing cable tray or along the wall or laid
through under floor chanel (Metal floor Race Way) as required.
52 Accessories for TV SYSTEM
N.S. Supply, erection, testing and commissioning of splitter / tap off mounted in suitable sizes
MS boxes for MATV system and shall be suitable for interactive system. Make:- (Reputed
of as directed by I/E or Consultant)
i) Two Way (S-2) (Make:- Reputed of as directed by I/E or Consultant) Each 2 334.00 668.00
ii) Two way tap off (T2) (Make:- Reputed of as directed by I/E or Consultant) Each 2 492.00 984.00
TOTAL OF NON SCHEDULE ITEMS (PART-B) 1,32,489.00
TOTAL (SCHEDULE + NON SCHEDULE ITEMS) (PART_A+B) 6,74,344.00
CIVIL ESTIMATE FOR THE PROPOSED CONSTRUCTION OF ASSEMBLY
Sl No. SOR No. Description of work Unit Rate (Rs.) Quantity
1 2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means
over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)
including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5
m, as directed by Engineer-in-charge.
2 2.7 Earth work in excavation by mechanical means (Hydralic excavator/manual
means)over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on
plan) including getting out and disposal of excavated earth, lead upto 50m and lift
upto 1.5m, as directed by Engineer - in Charge
3 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited
layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Cum. 196.00 256.27 50,228.72
4 2.27 Supplying and filling in plinth with sand under floors, including watering,
ramming, consolidating and dressing complete. Cum 2123.75 12.58 26,725.27
5 4.1 Providing and laying in position cement concrete of specified grade excluding the cost
of centering and shuttering - All work up to plinth level :
5.1 4.1.8 1 :4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from
natural sources : 8 graded stone aggregate 40 mm nominal
size derived from natural sources) Cum 6812.00 12.58 85,722.21
6 5.33 Providing and laying in position ready mixed or site batched design mix
cement concrete for reinforced cement concrete work; using coarse
aggregate and fine aggregate derived from natural sources, Portland
Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in
recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to
improve durability and workability without impairing strength; including pumping of
concrete to site of laying, curing, carriage for all leads; but excluding the cost of
centering, shuttering, finishing and reinforcement as per direction of the engineer-in-
charge; for the following grades of concrete. Note: Extra cement up to 10% of the
minimum specified cement content in design mix shall be payable separately. In case
the cement content in design mix is more than 110% of the specified minimum
cement content, the contractor shall have discretion to either re-design the mix or bear
the cost of extra cement.
6.1 5.33.1 All works up to plinth level
5.33.1.1 Concrete of M25 grade with minimum cement
7 5.9 Centering and shuttering including strutting, propping etc. and removal of form for :
7.1 5.9.1 Foundations, footings, bases of columns etc. for mass
7.2 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm. 961.30 78.00 74,981.40
8 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing
in position and binding all complete upto plinth level.
i 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg 107.85 9930.96 10,71,054.04
9 10.2 Structural steel work riveted, bolted or welded in built up sections, trusses
and framed work, including cutting, hoisting, fixing in position and applying
a priming coat of approved steel primer all complete. Kg 133.70 10719.80 14,33,237.26
10 10.25.2 Steel work welded in built up sections/ framed work, including cutting,
hoisting, fixing in position and applying a priming coat of approved steel
primer using structural steel etc. as required. In gratings, frames, guard bar, ladder,
railings, brackets, gates and similar works
Digitally signed by PRIYA
11 12.50 Providing and fixing precoated galvanised iron profile sheets (size, shape
and pitch of corrugation as approved by Engineer-in-Charge) of total
coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness
with total coating thickness of 0.05mm) with zinc coating 120 grams per
sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on
both side of the sheet and polyester top coat 15-18 microns. Sheet should
have protective guard film of 25 microns minimum to avoid scratches
during transportation and should be supplied in single length upto 12
metre or as desired by Engineer-in-charge. The sheet shall be fixed
using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM
seal, complete upto any pitch in horizontal/ vertical or curved surfaces,
excluding the cost of purlins, rafters and trusses and including cutting to
size and shape wherever required. Sqm 738.65 1500.00 11,07,975.00
12 12.51 Providing and fixing precoated galvanised steel sheet roofing accessories
of total coated thickness 0.50 mm (base metal of minimum 0.45 mm
thickness with total coating thickness of 0.05 mm) with Zinc coating 120
gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy
primer on both side of the sheet and polyester top coat 15-18 microns
using self drilling/ self tapping screws complete :
12.2 12.51.6 Gutter (600 mm over all girth) metre 1313.70 100.00 1,31,370.00
11 13.50 Applying priming coat :
11.1 13.50.3 With ready mixed red oxide zinc chromate primer of approved brand and manufacture
on steel galvanised iron/ steel works Sqm 67.40 1540.82 1,03,851.27
12 13.62 Painting with synthetic enamel paint of approved brand and manufacture of required
colour to give an even shade :
12.1 13.62.1 Two or more coats on new work over an under coat of suitable
shade with ordinary paint of approved brand and manufacture Sqm 226.25 1540.82 3,48,610.53
13 12.41 Providing and fixing on wall face unplasticised Rigid PVC rain water
pipes conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)
Single socketed pipes.
14 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/
accessories for unplasticised Rigid PVC rain water pipes conforming to IS
: 13592 Type A, including jointing with seal ring conforming to IS : 5382,
leaving 10 mm gap for thermal expansion.
12.42.2 Single pushfit Coupler 110 mm Each 127.60 24.00 3,062.40
15 12.43 Providing and fixing unplasticised -PVC pipe clips of approved design
to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard
wood plugs, screwed with M.S. screws of required length, including cutting
brick work and fixing in cement mortar 1 :4 (1 cement: 4 coarse sand) and
making good the wall etc. complete.
GR. TOTAL 79,57,892.24
Digitally signed by PRIYA
CIVIL ESTIMATE FOR THE PROPOSED CONSTRUCTION OF SUBSTATION BUILDING
Sl No. SOR No. Description of work Unit Rate (Rs.) Quantity
SUB-HEAD-2 EARTHWORKS
1 2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means
over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)
including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5
m, as directed by Engineer-in-charge.
2 2.7 Earth work in excavation by mechanical means (Hydralic excavator/manual
means)over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on
plan) including getting out and disposal of excavated earth, lead upto 50m and lift
upto 1.5m, as directed by Engineer - in Charge
3 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited
layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Cum. 196.00 80.41 15,759.97
4 2.27 Supplying and filling in plinth with sand under floors, including watering,
ramming, consolidating and dressing complete. Cum 2123.75 11.87 25,209.76
SUB-HEAD-3 MASONARY WORKS
1 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation
7.5 in foundation and plinth in:
1.1 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum. 7132.25 15.91 1,13,474.10
2 6.34 Brick work with non modular fly ash bricks conforming to IS:12894, class designation
10 average compressive strength in super structure above plinth level up to floor V
6.34.2 Cement mortar 1:6 (1 cement : 6 Coarse sand) Cum. 8752.55 36.29 3,17,630.04
SUB-HEAD-4 CONCRETE WORKS
1 4.1 Providing and laying in position cement concrete of specified grade excluding the cost
of centering and shuttering - All work up to plinth level :
1.1 4.1.5 1:3:6 (1 Cement: 3 coarse sand:6 graded stone aggregate 20 mm cum nominal size
2 4.17 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse
sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry
brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine
sand, including finishing the top smooth. sqm 749.30 19.20 14,386.56
3 5.33 Providing and laying in position ready mixed or site batched design mix
cement concrete for reinforced cement concrete work; using coarse
aggregate and fine aggregate derived from natural sources, Portland
Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in
recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to
improve durability and workability without impairing strength; including pumping of
concrete to site of laying, curing, carriage for all leads; but excluding the cost of
centering, shuttering, finishing and reinforcement as per direction of the engineer-in-
charge; for the following grades of concrete. Note: Extra cement up to 10% of the
minimum specified cement content in design mix shall be payable separately. In case
the cement content in design mix is more than 110% of the specified minimum
cement content, the contractor shall have discretion to either re-design the mix or bear
the cost of extra cement.
3.1 5.33.1 All works up to plinth level
5.33.1.1 Concrete of M25 grade with minimum cement
3.2 5.33.2 All work above Plinth level upto floor V Level.
5.33.2.1 Concrete of M25 grade with minimum cement
6 5.9 Centering and shuttering including strutting, propping etc. and removal of form for :
6.1 5.9.1 Foundations, footings, bases of columns etc. for mass
6.2 5.9.2 Walls (any thickness) including attached pilasters.
Butteresses, plinth and string courses etc. Sqm. 842.50 0.00 0.00
6.3 5.9.21 Lintels, beams, plinth beams, girders, bressumers and
cantilevers with water proof ply 12 mm thick. Sqm. 841.95 108.98 91,755.71
Digitally signed by PRIYA
6.5 5.9.20 Suspended floors, roofs, landings, balconies and access
platform with water proofply 12 mm thick. Sqm. 1028.40 78.96 81,202.46
6.7 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm. 961.30 28.35 27,252.86
6.9 5.9.19 Weather shade,Chajjas, corbels etc. including edges Sqm. 951.10 3.24 3,081.56
7 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing
in position and binding all complete upto plinth level.
i 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg 107.85 1265.40 1,36,473.39
8 5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing
in position and binding all complete above plinth level.
i 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg 107.85 2746.75 2,96,237.40
9 26.86 Providing and fixing factory made single extruded WPC (Wood Polymer Composite)
solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin
PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural
fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity
index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent
cement and screwed with full body threaded star headed SS screws having minimum
frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N
(Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900
N/mm2 and resistance to spread of flame of Class A category with property of being
termite/borer proof, water/moisture proof and fire retardant and fixed in position with
M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per
direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be
paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance
in dimensions i.e depth and width of profile shall be acceptable. Variation in profile
dimensions on plus side shall be acceptable but no extra payment on this account
10 26.87 Providing and fixing factory made single extruded WPC (Wood Polymer Composite)
solid plain flush door shutter of required size comprising of virgin polymer of K value
58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice
husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)
having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N
(Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of
elasticity 850 N/mm2 and resistance to spread of flame of Class A category with
property of being termite/ borer proof, water/moisture proof and fire retardant and
fixing with stainless steel butt hinges of required size with necessary full body
threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-
Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid
11 9.165 Providing and fixing bright /matt finished Stainless Steel handles of
approved quality & make with necessary screws etc all complete.
12 9.96.2 Providing and fixing aluminium sliding door bolts, ISi marked anodised
(anodic coating not less than grade AC 10 as per IS : 1868), transparent
or dyed to required colour or shade, with nuts and screws etc. complete : (250x16
13 9.97 Providing and fixing aluminium tower bolts, ISi marked, anodised (anodic
coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed
to required colour or shade, with necessary screws etc. complete :
14 9.82 Providing and fixing bright finished brass hanging type floor door stopper
with necessary screws, etc. complete. Each 121.65 1.00 122.00
SUB-HEAD-5 STEEL WORKS
1 9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S.
flats, square or round bars etc. including priming coat with approved steel primer all
1.1 9.48.2 welding Fixed to openings/ wooden frames with rawl plugs Kg. 238.35 135.00 32,177.25
2 10.5.1 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron
and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings
complete, including applying a priming coat of approved steel primer. Using M.S.
angels 40x40x6 mm for diagonal braces. Sqm 5804.35 0.00 0.00
Digitally signed by PRIYA
3 10.6.1 Supplying and fixing rolling shutters of approved make, made of required
size M.S. laths, interlocked together through their entire length and jointed
together at the end by end locks, mounted on specially designed pipe
shaft with brackets, side guides and arrangements for inside and outside
locking with push and pull operation complete, including the cost of
providing and fixing necessary 27.5 cm long wire springs manufactured
from high tensile steel wire of adequate strength conforming to IS: 4454 -
part 1 and M.S. top cover of required thickness for rolling shutters.
80x1 .25 mm M.S. laths with 1.25 mm thick top cover
4.1 10.18 Providing and fixing circular/hexagonal cast iron or M.S sheet box for
ceiling fan clamp 140 mm internal dia, 73 mm height, 5 mm thick rim
bottom and top lids, 1.5 mm thick M.S sheet with its top surface hacked for
proper bonding top lid shall be screwed into the cast iron box by means of
3.3 mm dia round headed screws, one lock at the corners. Clamps shall be
made of 12 mm dia M.S. bar bent to shape as per standard drawing. Each 220.65 4.00 882.60
5.1 10.25.2 Steel work welded in built up sections/ framed work, including cutting,
hoisting, fixing in position and applying a priming coat of approved steel
primer using structural steel etc. as required. In gratings, frames, guard bar, ladder,
railings, brackets, gates and similar works
SUB-HEAD-6 WOOD & uPVC/ PVC WORKS
6.1 21.1.2.2 Providing and fixing aluminium work for doors, windows, ventilators and
partitions with extruded built up standard tubular sections/ appropriate Z
sections and other sections of approved make conforming to IS: 733 and IS:
1285, fixing with dash fasteners of required dia and size, including necessary
filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM
rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free,
straight, mitred and jointed mechanically wherever required including cleat
angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel
screws, all complete as per architectural drawings and the directions of
Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for
separately) : For shutters of doors, windows & ventilators including providing
and fixing hinges/ pivots and making provision for fixing of fittings wherever
required including the cost of EPDM rubber / neoprene gasket required (Fittings
shall be paid for separately) Powder coated aluminium (minimum thickness of
powder coating 50 micron)
15 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and
partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the
architectural drawings and the directions of engineer-in-charge . (Cost of aluminium
snap beading shall be paid in basic item):
15.1 21.3.2 With float glass panes of 5.0 mm thickness (weight not less
SUB-HEAD-7 FLOORING WORKS
16 11.4 52 mm thick cement concrete flooring with concrete hardener topping,
under layer 40 mm thick cement concrete 1 :2:4 (1 cement : 2 coarse
sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12
mm thick cement hardener consisting of mix 1 :2 (1 cement hardener mix
: 2 graded stone aggregate 6 mm nominal size) by volume, hardening
compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's
specifications. This includes cost of cement slurry, but excluding the cost
of nosing of steps etc. complete. Sqm 978.45 90.25 88,305.11
17 11.6 Cement plaster skirting up to 30 cm height, with cement mortar 1 :3 (1
cement : 3 coarse sand), finished with a floating coat of neat cement. Sqm 662.05 7.98 5,283.16
18 11.13 Providing and fixing glass strips in joints of terrazo/ cement concrete
40 mm wide and 4 mm thick Rmt. 91.75 315.88 28,981.53
SUB-HEAD-9 PLASTER WORK
17 13.4 12 mm cement plaster of mix :
18 13.16 6 mm cement plaster of mix :
19 13.5.2 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement:
Digitally signed by PRIYA
20 MR-6 Providing and fixing 24 gauge Chicken Wire mesh in junction of block work & RCC
works at corner/wall surface as per direction of Engineer-In-Charge. Sqm Rate only 266.86
Roof Waterproofing
21 22.7 Providing and laying integral cement based water proofing treatment
including preparation of surface as required for treatment of roofs,
balconies, terraces etc consisting of following operations:
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement
admixed with water proofing compound conforming to IS. 2645 and
approved by Engineer-in-charge over the RCC slab including adjoining
walls upto 300 mm height including cleaning the surface before treatment.
(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm
to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse
sand) admixed with water proofing compound conforming to IS : 2645
and approved by Engineer-in-charge over 20 mm thick layer of cement
mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-in-charge
to required slope and treating similarly the adjoining walls upto 300 mm
height including rounding of junctions of walls and slabs.
(c) After two days of proper curing applying a second coat of cement slurry
using 2.75 kg/ sqm of cement admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge.
(d) Finishing the surface with 20 mm thick jointless cement mortar of mix
1:4 (1 cement :4 coarse sand) admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge including
laying glass fibre cloth of approved quality in top layer of plaster and
finally finishing the surface with trowel with neat cement slurry and making
pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be
flooded with water for a minimum
period of two weeks for curing and for final test. “All above operations to be
done in order and as directed and specified by the Engineer-in-Charge”:
22.7.1 With average thickness of 120 mm and minimum thickness
SUB-HEAD-11 FINISHING WORK
22 13.83.2 Wall painting with premium acrylic emulsion paint of interior grade, having VOC
(Volatile Organic Compound ) content less than 50 grams/ litre of approved brand
and manufacture, including applying additional coats wherever required to achieve
even shade and colour. Two coats sqm 142.80 324.08 46,278.62
23 13.85.3 Applying priming coats with primer of approved brand and manufacture,
having low VOC (Volatile Organic Compound ) content. With water thinnable cement
primer on wall surface having VOC content less than 50 grams/litre Sqm 73.95 324.08 23,965.72
23.00 13.47.1.1 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of
required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and
including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
23 13.50 Applying priming coat :
23.1 13.50.3 With ready mixed red oxide zinc chromate primer of approved brand and manufacture
on steel galvanised iron/ steel works Sqm 67.40 46.08 3,105.79
24 13.62 Painting with synthetic enamel paint of approved brand and manufacture of required
colour to give an even shade :
24.1 13.62.1 Two or more coats on new work over an under coat of suitable
shade with ordinary paint of approved brand and manufacture Sqm 226.25 46.08 10,425.60
24 12.22 Making khurras 45x45 cm with average minimum thickness of 5 cm cement
concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of
20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished
with 12 mm cement plaster 1 :3 (1 cement : 3 coarse sand) and a coat
of neat cement, rounding the edges and making and finishing the outlet
25 12.41 Providing and fixing on wall face unplasticised Rigid PVC rain water
pipes conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)
Single socketed pipes.
Digitally signed by PRIYA
26 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/
accessories for unplasticised Rigid PVC rain water pipes conforming to IS
: 13592 Type A, including jointing with seal ring conforming to IS : 5382,
leaving 10 mm gap for thermal expansion.
12.42.2 Single pushfit Coupler 110 mm Each 127.60 2.00 255.20
27 12.43 Providing and fixing unplasticised -PVC pipe clips of approved design
to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard
wood plugs, screwed with M.S. screws of required length, including cutting
brick work and fixing in cement mortar 1 :4 (1 cement: 4 coarse sand) and
making good the wall etc. complete.
28 12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating
15 cm diameter and weighing not less than 440 grams. Each 54.70 2.00 109.40
GR. TOTAL 23,16,056.35
Digitally signed by PRIYA
CIVIL ESTIMATE FOR THE PROPOSED CONSTRUCTION OF CANTEEN KIOSK
Sl No. SOR No. Description of work Unit Rate (Rs.) Quantity D.S.R-2023
1 2.6 Earth work in excavation by mechanical means (Hydraulic excavator) / manual
means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on
plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m,
disposed earth to be levelled and neatly dressed.
2.6.1 All kinds of soil Cum. 177.50 12.96 2,301.00
2 2.25 Filling available excavated earth (excluding rock) in trenches, plinth,sides of
foundations etc. in layers not exceeding 20cm in depth, consolidating each
deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Cum. 196.00 8.04 1,576.00
3 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming,
consolidating and dressing complete. Cum. 2123.75 1.98 4,206.00
4 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation
7.5 in foundation and plinth in:
i 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 7132.25 2.38 16,939.09
5 6.32 Brick work with clay flyash F.P.S. (non modular) brick of class designation
7.5 in superstructure above plinth level up to floor five level in :
6.32.2 Cement mortar 1 :6 (1 cement : 6 coarse sand) Cum 9095.05 4.58 41,679.00
6 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks
of class designation 7.5 in superstructure above plinth level up to floor
6.1 6.13.2 Cement mortar 1 :4 (1 cement :4 coarse sand) Sqm 1123.80 5.40 6,069.00
7 4.1 Providing and laying in position cement concrete of specified grade excluding the
cost of centering and shuttering - All work up to plinth level :
4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone
aggregate 20 mm nominal size) cum 7,780.30 1.76 13,655.00
8 5.33 Providing and laying in position ready mixed or site batched design mix cement
concrete for reinforced cement concrete work; using coarse aggregate and fine
aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland
/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to
accelerate I retard setting of concrete, to improve durability and workability without
impairing strength; including pumping of concrete to site of laying, curing, carriage
for all leads; but excluding the cost of centering, shuttering, finishing and
reinforcement as per direction of the engineer-in-charge, for the following grades of
Note: Extra cement up to 10% of the minimum specified cement content in design
mix shall be payable separately. In case the cement content in design mix is more
than 110% of the specified minimum cement content, the contractor shall have
discretion to either re-design the mix or bear the cost of extra cement.
8.1 5.33.1.1 All works upto plinth level. Concrete of M25 grade with minimum cement content of
8.2 5.33.2.1 All works above plinth level upto floor V level. Concrete of M25 grade with minimum
cement content of 330 kg /cum Cum. 9,860.40 6.56 64,685.00
9 5.9 Centering and shuttering including strutting, propping etc. and removal of form for :
9.1 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete Sqm 392.15 14.76 5,789.00
9.2 5.9.3 Suspended floors, roofs, landings, balconies and access
9.3 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 961.30 20.40 19,611.00
9.4 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers Sqm 736.40 2.70 1,989.00
10 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending,
placing in position and binding all complete upto plinth level.
10.1 5.22.6 Thermo-Mechanically Treated bars Kg. 107.85 158.40 17,084.00
10 5.22A Steel reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete above plinth level.
10.2 5.22A.6 Thermo-Mechanically Treated bars Kg. 107.85 526.33 56,765.00
Digitally signed by PRIYA
11.0 26.86 Providing and fixing factory made single extruded WPC (Wood Polymer Composite)
solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of
virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and
natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives
(maximum toxicity index of 12 for 100 gms) fabricated with miter joints after
applying PVC solvent cement and screwed with full body threaded star headed SS
screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of
2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2,
modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A
category with property of being termite/borer proof, water/moisture proof and fire
retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required
dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs
or SS dash fasteners shall be paid for separately).Note: For WPC solid
door/window frames, minus 5mm tolerance in dimensions i.e depth and width of
profile shall be acceptable. Variation in profile dimensions on plus side shall be
acceptable but no extra payment on this account shall be made.
12.0 26.87 Providing and fixing factory made single extruded WPC (Wood Polymer Composite)
solid plain flush door shutter of required size comprising of virgin polymer of K value
58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/
rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100
gms) having minimum density of 650 kg/cum and screw withdrawal strength of
1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2,
modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A
category with property of being termite/ borer proof, water/moisture proof and fire
retardant and fixing with stainless steel butt hinges of required size with necessary
full body threaded star headed counter sunk S.S screws, all as per direction of
Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws
shall be paid separately)
13.0 9.96.2 Providing and fixing aluminium sliding door bolts, ISi marked anodised
(anodic coating not less than grade AC 10 as per IS : 1868), transparent
or dyed to required colour or shade, with nuts and screws etc. complete : (250x16
14.0 9.97 Providing and fixing aluminium tower bolts, ISi marked, anodised (anodic
coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed
to required colour or shade, with necessary screws etc. complete :
15.0 9.165 Providing and fixing bright /matt finished Stainless Steel handles of
approved quality & make with necessary screws etc all complete.
16.0 10.6 Supplying and fixing rolling shutters of approved make, made of required
size M.S. laths, interlocked together through their entire length and jointed
together at the end by end locks, mounted on specially designed pipe
shaft with brackets, side guides and arrangements for inside and outside
locking with push and pull operation complete, including the cost of
providing and fixing necessary 27.5 cm long wire springs manufactured
from high tensile steel wire of adequate strength conforming to IS: 4454 -
part 1 and M.S. top cover of required thickness for rolling shutters.
16.1 10.6.1 80x1 .25 mm M.S. laths with 1.25 mm thick top cover Sqm 3653.20 2.76 10,083.00
17.0 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622
(thickness to be specified by the manufacturer), of approved make, in all colours,
shades except burgundy, bottle green, black of any size as approved by Engineer-
in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement
mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg
per sqm, including pointing in white cement mixed with pigment of matching shade
18.0 11.26.1 Kota stone slab flooring over 20 mm (average) thick base laid over and
jointed with grey cement slurry mixed with pigment to match the shade of
the slab, including rubbing and polishing complete with base of cement
mortar 1 : 4 (1 cement : 4 coarse sand) :
Digitally signed by PRIYA
19.0 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars
laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse
sand) and jointed with grey cement slurry mixed with pigment to match
the shade of the slabs, including rubbing and polishing complete. Sqm 2354.70 1.50 3,533.00
20.0 13.4 12 mm cement plaster of mix :
21.0 13.16 6 mm cement plaster of mix :
22.0 13.14 15 mm cement plaster 1:2 (1 cement : 2 stone dust) on the rough side of
single or half brick wall. sqm 437.20 33.83 14,789.00
23 13.83.2 Wall painting with premium acrylic emulsion paint of interior grade, having VOC
(Volatile Organic Compound ) content less than 50 grams/ litre of approved brand
and manufacture, including applying additional coats wherever required to achieve
even shade and colour. Two coats Sqm 142.80 25.95 3,706.00
24 13.85.3 Applying priming coats with primer of approved brand and manufacture,
having low VOC (Volatile Organic Compound ) content. With water thinnable
cement primer on wall surface having VOC content less than 50 grams/litre Sqm 73.95 25.95 1,920.00
23 DSR 13.47 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of
required shade :
23.1 13.47.1 New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including
priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) sqm 171.10 33.83 5,788.00
24.0 13.62 Painting with synthetic enamel paint of approved brand and manufacture of
required colour to give an even shade :
13.62.1 Two or more coats on new work over an under coat of suitable
shade with ordinary paint of approved brand and manufacture Sqm 226.25 5.52 1,249.00
25 22.22A Providing and applying fibre reinforced elastomeric liquid water proofing membrane
with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of
concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of
elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two
coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete
application/system not less than 500 microns). The operation shall be carried out
after scrapping and properly cleaning the surface to remove loose particles with
wire brushes, complete in all respect as per the direction of Engineerin-
26 22.14.1 Grading roof for water proofing treatment with. Cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size) Cum 8042.30 0.70 5,630.00
Digitally signed by PRIYA
CONSTRUCTION OF BOUNDARY WALL & GATE WITH GUARD ROOM FOR KENDRIYA VIDYALAYA SCHOOL
CAMPUS, BARKATHA, DIST.- HAZARIBAGH, JHARKHAND
Amount as per Amount as per Amount as
Sl. No. DESCRIPTION Total Cost
DSR-2023 DSR-2025 per N.S Items
1 BOUNDARY WALL
1.1 Front Boundary Wall With MS grill (Length-153 m) 29,39,179.00 29,39,179.00
1.2 Rear and Side Boundarywall Wall Wilth Concertina Coil
1.3 Boundary wall for Principal Qtr.
2 MAIN ENTRANCE GATE WITH GUARD ROOM-1
2.1 Main Entrance Gate & Guard Room (Civil works) 16,49,046.00 71989.00 17,21,035.00
2.2 Plumbing & Sanitary Works 1,51,772.10 3036.30 1,54,808.40
2.3 Septic Tank (10 Users) 73,363.76 73,363.76
3 GATE WITH GUARD ROOM - 2 & 3
3.1 Gate with Guard Room-2 Nos.
( Residential Entry & School Exit Gate) 15,88,642.00 66904.00 16,55,546.00
Digitally signed by PRIYA
CIVIL ESTIMATE FOR THE PROPOSED CONSTRUCTION OF BOUNDRY WALL WITH MS GRILL
Sl No. SOR No. Description of work Unit Rate (Rs.) Quantity D.S.R-2023
SUB-HEAD-1 EARTHWORKS
1 2.6 Earth work in excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30 cm in depth,
1.5 m in width as well as 10 sqm on plan) including getting out and
disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as
directed by Engineer-in-charge.
2 2.25 Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundations etc. in layers not exceeding 20cm in
depth, consolidating each deposited layer by ramming and
watering, lead up to 50 m and lift upto 1.5 m. Cum. 196.00 228.58 44,801.00
3 2.27 Supplying and filling in plinth with sand under floors, including
watering, ramming, consolidating and dressing complete.. Cum. 2123.75 13.46 28,587.00
SUB-HEAD-2 MASONARY WORKS
4 6.32 Brick work with clay flyash F.P.S. (non modular) brick of class
designation 7.5 in superstructure above plinth level up to floor five
6.32.2 Cement mortar 1 :6 (1 cement : 6 coarse sand) Cum. 9095.05 63.11 5,74,012.00
SUB-HEAD-3 CONCRETE WORKS
5 4.1 Providing and laying in position cement concrete of specified grade
excluding the cost of centering and shuttering - All work up to plinth
4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone
aggregate 20 mm nominal size) cum 7,294.70 13.74 1,00,229.00
6 5.33 Providing and laying in position machine batched and machine
mixed design mix M-25 grade cement concrete for reinforced
cement concrete work, using cement content as per approved
design mix, including pumping of concrete to site of laying but
excluding the cost of centering, shuttering, finishing and
reinforcement, including admixtures in recommended proportions
as per IS: 9103 to accelerate, retard setting of concrete, improve
workability without impairing strength and durability as per direction
of Engineer-in-charge.
6.1 5.33.1.1 All works upto plinth level Cum. 9504.75 28.54 2,71,226.00
6.2 5.33.2.1 All works above plinth level upto floor V level Cum. 9,860.40 27.51 2,71,308.00
SUB-HEAD-4 CENTERING AND SHUTTERING WORK
7 5.9 Centering and shuttering including strutting, propping etc. and
removal of form for :
7.1 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
7.2 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
7.3 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 961.30 182.42 1,75,365.00
8 5.28 Providing and fixing in position 12 mm thick bitumen impregnated per
fiber board conforming to IS: 1838, including cost of primer, sealing cm
compound Grade-A in expansion joints. depth
SUB-HEAD-5 STEEL WORK
9 5.22 Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete upto
9.1 5.22.6 Thermo-Mechanically Treated bars Kg. 107.85 2568.22 2,76,983.00
9 5.22A Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete above
9.2 5.22A.6 Thermo-Mechanically Treated bars Kg. 107.85 4175.95 4,50,377.00
Digitally signed by PRIYA
10 10.25 Steel work welded in built up sections/ framed work, including
cutting, hoisting, fixing in position and applying a priming coat of
approved steel primer using structural steel etc. as required.
10.1 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates
and similar works Kg. 172.60 1514.70 2,61,438.00
SUB-HEAD-6 PLASTER & FINISHING WORK
11 13.4 12 mm cement plaster of mix :
12 13.44 Finishing walls with water proofing cement paint of required shade
13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm) sqm 116.90 641.95 75,044.00
13 13.62 Painting with synthetic enamel paint of approved brand and
manufacture to give an even shade
13.61.1 Two or more coats on new work. sqm 226.25 10.53 2,382.00
GR. TOTAL 29,39,179.00
Digitally signed by PRIYA
CIVIL ESTIMATE FOR THE PROPOSED CONSTRUCTION OF EXTERNAL BOUNDRY WALL WITH CONCERTINA COIL FENCING.
Sl No. SOR No. Description of work Unit Rate (Rs.) Quantity D.S.R-2023
SUB-HEAD-1 EARTHWORKS
1 2.6 Earth work in excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30 cm in depth, 1.5
m in width as well as 10 sqm on plan) including getting out and
disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as
directed by Engineer-in-charge.
2 2.25 Filling available excavated earth (excluding rock) in trenches, plinth,
sides of foundations etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up
3 2.27 Supplying and filling in plinth with sand under floors, including
watering, ramming, consolidating and dressing complete.. Cum. 2123.75 73.23 1,55,524.00
SUB-HEAD-2 MASONARY WORKS
4 6.32 Brick work with clay flyash F.P.S. (non modular) brick of class
designation 7.5 in superstructure above plinth level up to floor five
6.32.2 Cement mortar 1 :6 (1 cement : 6 coarse sand) Cum. 9095.05 371.25 33,76,538.00
SUB-HEAD-3 CONCRETE WORKS
5 4.1 Providing and laying in position cement concrete of specified grade
excluding the cost of centering and shuttering - All work up to plinth
4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone
aggregate 20 mm nominal size) cum 7,294.70 72.89 5,31,718.00
6 5.33 Providing and laying in position machine batched and machine mixed
design mix M-25 grade cement concrete for reinforced cement
concrete work, using cement content as per approved design mix,
including pumping of concrete to site of laying but excluding the cost of
centering, shuttering, finishing and reinforcement, including
admixtures in recommended proportions as per IS: 9103 to
accelerate, retard setting of concrete, improve workability without
impairing strength and durability as per direction of Engineer-in-
6.1 5.33.1.1 All works upto plinth level Cum. 9504.75 151.39 14,38,936.00
6.2 5.33.2.1 All works above plinth level upto floor V level Cum. 9,860.40 154.57 15,24,098.00
SUB-HEAD-4 CENTERING AND SHUTTERING WORK
7 5.9 Centering and shuttering including strutting, propping etc. and removal
7.1 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete Sqm 392.15 694.95 2,72,525.00
7.2 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers Sqm 736.40 660.00 4,86,024.00
7.3 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 961.30 966.24 9,28,847.00
8 5.28 Providing and fixing in position 12 mm thick bitumen impregnated fiber per
board conforming to IS: 1838, including cost of primer, sealing cm
compound Grade-A in expansion joints. depth
SUB-HEAD-5 STEEL WORK
9 5.22 Steel reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete upto plinth level.
9.1 5.22.6 Thermo-Mechanically Treated bars Kg. 107.85 13625.21 14,69,480.00
9 5.22A Steel reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete above plinth
9.2 5.22A.6 Thermo-Mechanically Treated bars Kg. 107.85 21347.10 23,02,285.00
10 10.25 Steel work welded in built up sections/ framed work, including cutting,
hoisting, fixing in position and applying a priming coat of approved
steel primer using structural steel etc. as required.
10.1 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates
and similar works Kg. 172.60 2565.00 4,42,719.00
Digitally signed by PRIYA
11.0 16.53 Providing and fixing concertina coil fencing with punched tape
concertina coil 600 mm dia 10 metre openable length ( total length 90
m), having 50 nos rounds per 6 metre length, upto 3 m height of wall
with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and
with 9 horizontal R.B.T. reinforced barbed wire, stud tied with
G.I. staples and G.I. clips to retain horizontal, including necessary
bolts or G.I. barbed wire tied to angle iron, all complete as per
direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) /
Spring core (2.5mm thick) wire of high tensile strength of 165 kg/
sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost
of M.S. angle, C.C. blocks shall be paid separately)
SUB-HEAD-6 PLASTER & FINISHING WORK
12 13.4 12 mm cement plaster of mix :
13 13.44 Finishing walls with water proofing cement paint of required shade :
13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm) sqm 116.90 4696.35 5,49,004.00
14 13.62 Painting with synthetic enamel paint of approved brand and
manufacture to give an even shade
13.61.1 Two or more coats on new work. sqm 226.25 142.50 32,241.00
Digitally signed by PRIYA
CIVIL ESTIMATE FOR THE PROPOSED CONSTRUCTION OF BOUNDARY WALL FOR PRINCIPAL QTR.
Sl No. SOR No. Description of work Unit Rate (Rs.) Quantity D.S.R-2023
SUB-HEAD-1 EARTHWORKS
1 2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means
over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)
including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5
m, as directed by Engineer-in-charge.
2 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited
layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Cum. 196.00 63.33 12,412.86
3 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming,
consolidating and dressing complete.. Cum. 2123.75 0.00 0.00
SUB-HEAD-2 MASONARY WORKS
4 6.34 Brick work with non modular fly ash bricks conforming to IS:12894, class designation
10 average compressive strength in super structure above plinth level up to floor V
6.34.2 Cement mortar 1:6 (1 cement : 6 Coarse sand) Cum. 8752.55 26.60 2,32,817.83
SUB-HEAD-3 CONCRETE WORKS
5 4.1 Providing and laying in position cement concrete of specified grade excluding the cost
of centering and shuttering - All work up to plinth level :
5.1 4.1.5 1:3:6 (1 Cement: 3 coarse sand:6 graded stone aggregate 20 mm cum nominal size
6 5.33 Providing and laying in position ready mixed or site batched design mix
cement concrete for reinforced cement concrete work; using coarse
aggregate and fine aggregate derived from natural sources, Portland
Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in
recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to
improve durability and workability without impairing strength; including pumping of
concrete to site of laying, curing, carriage for all leads; but excluding the cost of
centering, shuttering, finishing and reinforcement as per direction of the engineer-in-
charge; for the following grades of concrete. Note: Extra cement up to 10% of the
minimum specified cement content in design mix shall be payable separately. In case
the cement content in design mix is more than 110% of the specified minimum cement
content, the contractor shall have discretion to either re-design the mix or bear the
cost of extra cement.
6.1 5.33.1 All works up to plinth level
5.33.1.1 Concrete of M25 grade with minimum cement
content of 330 kg /cum Cum. 9504.75 9.36 88,940.70
6.2 5.33.2 All work above Plinth level upto floor V Level.
6.2.1 5.33.2.1 Concrete of M25 grade with minimum cement
7 5.9 Centering and shuttering including strutting, propping etc. and removal of form for :
7.1 5.9.1 Foundations, footings, bases of columns etc. for mass
7.2 5.9.21 Lintels, beams, plinth beams, girders, bressumers and
cantilevers with water proof ply 12 mm thick. Sqm. 841.95 56.75 47,777.86
7.3 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm. 961.30 69.52 66,829.58
8 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing
in position and binding all complete upto plinth level.
8.1 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg 107.85 1265.88 136524.62
8.2 5.22A Steel reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete above plinth level.
5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or
SUB-HEAD-4 STEEL WORKS
9 10.25 Steel work welded in built up sections/framed worK including cutting
hoisting, rixing in position andapplying a priming coat of approved steel
primer using structural steel, etc. as required.
9.1 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets,
gates and similar works Kg. 172.60 1198.08 2,06,788.61
SUB-HEAD-5 PLASTER WORK
10 13.3 20 mm cement plaster of mix ;
SUB-HEAD-6 FINISHING WORK
12 13.47 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone
additives of required shade:
Digitally signed by PRIYA
12.1 13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over
and including priming coat of exterior primer applied @ 0.90
13 13.62 Painting with synthetic enamel paint of approved brand and manufacture of required
colour to give an even shade :
13.1 13.62.1 Two or more coats on new work over an under coat of suitable
shade with ordinary paint of approved brand and manufacture sqm 226.25 68.10 15,406.72
GR. TOTAL 15,33,001.56
Digitally signed by PRIYA
CIVIL ESTIMATE FOR THE PROPOSED CONSTRUCTION OF ENTRANCE GATE & GUARD ROOM -1
Sl No. SOR No. Description of work Unit Rate (Rs.) Quantity D.S.R-2023
SUB-HEAD-1 EARTHWORKS
1 2.6 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over
areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including
disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled
and neatly dressed.
2.6.1 All kinds of soil Cum. 177.50 55.61 9,871.00
2 2.25 Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc.
in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and
watering, lead up to 50 m and lift upto 1.5 m. Cum. 196.00 45.53 8,925.00
3 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming,
consolidating and dressing complete. Cum. 2123.75 3.00 6,380.00
SUB-HEAD-2 MASONARY WORKS
4 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in
foundation and plinth in:
6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum. 7132.25 3.27 23,339.00
5 6.32 Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in
superstructure above plinth level up to floor five level in :
5.1 6.32.2 Cement mortar 1 :6 (1 cement : 6 coarse sand) Cum. 9095.05 10.74 97,693.00
6 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks
of class designation 7.5 in superstructure above plinth level up to floor
6.1 6.13.2 Cement mortar 1 :4 (1 cement :4 coarse sand) Sqm 1123.80 21.64 24,317.00
7 6.15 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of
half brick masonry. Sqm 104.80 21.64 2,268.00
8 6.47 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to
300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185
(Part 3) in super structure above plinth level up to floor V level with RCC band at sill level
and lintel level with approved block laying polymer modified adhesive mortar all complete as
per direction of Engineer-in-Charge. {The payment of RCC band and reinforcement shall be
made for seperately). Cum. 8333.65 5.10 42,502.00
SUB-HEAD-3 CONCRETE WORKS
9 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of
centering and shuttering - All work up to plinth level :
4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone
aggregate 20 mm nominal size) cum 7,780.30 5.02 39,073.00
10 5.33 Providing and laying in position ready mixed or site batched design mix cement concrete for
reinforced cement concrete work; using coarse aggregate and fine aggregate derived from
natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures
in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to
improve durability and workability without impairing strength; including pumping of concrete
to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,
finishing and reinforcement as per direction of the engineer-in-charge, for the following
grades of concrete.:
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall
be payable separately. In case the cement content in design mix is more than 110% of the
specified minimum cement content, the contractor shall have discretion to either re-design
the mix or bear the cost of extra cement.
10.1 5.33.1.1 All works upto plinth level. Concrete of M25 grade with minimum cement content of 330 kg
10.2 5.33.2.1 All works above plinth level upto floor V level. Concrete of M25 grade with minimum cement
SUB-HEAD-4 CENTERING AND SHUTTERING WORK
11 5.9 Centering and shuttering including strutting, propping etc. and removal of form for :
11.1 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete Sqm 392.15 38.26 15,004.00
11.2 5.9.3 Suspended floors, roofs, landings, balconies and access
11.3 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers Sqm 736.40 54.79 40,346.00
11.4 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 961.30 54.72 52,603.00
SUB-HEAD-5 STEEL WORK
12 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete upto plinth level.
12.1 5.22.6 Thermo-Mechanically Treated bars Kg. 107.85 913.51 98,523.00
13 5.22A Steel reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete above plinth level.
13.1 5.22A.6 Thermo-Mechanically Treated bars Kg. 107.85 2256.11 2,43,322.00
14 9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats,
square or round bars etc. including priming coat
with approved steel primer all complete.
14.1 9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc. Kg. 238.35 54.00 12,871.00
Digitally signed by PRIYA
15 10.18 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of
internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface
hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by
means of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of
12mm dia M.S. bar bent to shape as per standard drawing. each 220.65 2.00 442.00
16 10.25 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in
position and applying a priming coat of approved steel primer using structural steel etc. as
10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates
and similar works Kg. 172.60 1719.00 2,96,700.00
SUB HEAD 5 : WOOD WORK & ALUMINIUM WORK
17.0 9.21 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-
decorative type, core of block board construction with frame of 1st class hard wood and well
matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on
both faces of shutters :
17.1 9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws Sqm 2,392.65 3.78 9,045.00
18.0 26.86 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid
door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC
polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood
powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100
gms) fabricated with miter joints after applying PVC solvent cement and screwed with full
body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw
withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58
N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A
category with property of being termite/borer proof, water/moisture proof and fire retardant
and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length
complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners
shall be paid for separately).Note: For WPC solid door/window frames, minus 5mm
tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile
dimensions on plus side shall be acceptable but no extra payment on this account shall be
18.1 26.86.1 Frame size 45 x 70 mm
18.2 26.86.4 Frame size 50 x 125 mm
19.0 26.87 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid
plain flush door shutter of required size comprising of virgin polymer of K value 58-60
(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat
husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum
density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge),
minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance
to spread of flame of Class A category with property of being termite/ borer proof,
water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required
size with necessary full body threaded star headed counter sunk S.S screws, all as per
direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S
screws shall be paid separately)
20.0 9.70.2 Providing and fixing IS : 12817 marked stainless steel butt hinges with
stainless steel screws etc. complete : 100X58X1.90 mm Each 107.10 4.00 429.00
21.0 9.96 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not
less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade,
with nuts and screws etc. complete :
22.0 9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less
than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with
necessary screws etc. complete :
23.0 9.100 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than
grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with
necessary screws etc. complete :
24.0 9.101 Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic
coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required colour
and shade, with necessary screws etc. complete.
24.1 9.101.2 Twin rubber stopper each 72.35 2.00 145.00
25 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with
extruded built up standard tubular sections/ appropriate Z sections and other sections of
approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia
and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides
with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust
free, straight, mitred and jointed mechanically wherever required including cleat angle,
Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all
complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing,
paneling and dash fasteners to be paid for separately) :
Digitally signed by PRIYA
25.1 21.1.2 For shutters of doors, windows & ventilators including
providing and fixing hinges/ pivots and making provision
for fixing of fittings wherever required including the cost of
EPDM rubber / neoprene gasket required (Fittings shall be
paid for separately)
25.2 21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 634.45 27.36 17,359.00
26 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc.
with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the
directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic
26.1 21.3.1 With float glass panes of 4.0 mm thickness (weight not less
SUB HEAD 6 : FLOORING WORK & WALL TILES
27.0 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to
be specified by the manufacturer), of approved make, in all colours, shades except
burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting,
risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse
sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white
cement mixed with pigment of matching shade complete. Sqm 1267.95 12.18 15,444.00
28.0 11.40 Providing and fixing rectified glazed floor tiles 300x300mm 1st quality conforming to IS:
15622 (thickness to be specified by the manufacture) of approved make in all colours,
shades except burgundy, bottle green, black of any size laid over 20 mm thick bed of
cement Mortar 1:4 (1 cement: 4coarse sand) and jointing with white cement slurry and
matching pigment complete Sqm 1439.40 2.60 3,741.00
29.0 DSR Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the
11.41A manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of
approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement
mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including
grouting the joints with white cement and matching pigments etc. The tiles must be cut with
the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel,
plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the
29.1 11.41A.1.1 Double charge vitrified tile polished finish of size (Size of Tile 600 x 600 mm)
30.0 8.9.1.2 Stone tile (polished) work for wall lining over 12 mm thick bed of cement
mortar 1 :3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm
including pointing in white cement complete. 8 mm thick
Granite of any colour and shade Sqm 3617.55 9.90 35,814.00
31.0 12.20 Providing and laying pressed clay tiles (as per approved pattern 20 mm
nominal thickness of approved size) on roofs jointed with cement mortar
1 :4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing
compound, laid over a bed of 20 mm thick cement mortar 1 :4 (1 cement :
4 coarse sand) and finished neat complete. Sqm 709.75 16.00 11,356.00
SUB-HEAD-6 PLASTER & FINISHING WORK
32 13.4 12 mm cement plaster of mix :
33.0 13.11 18 mm cement plaster in two coats under layer 12 mm thick cement
plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm
thick cement plaster 1:6 (1 cement : 6 fine sand). sqm 518.55 176.39 91,468.00
34 13.16 6 mm cement plaster of mix :
35 13.41.1 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than
50 gram/litre, of approved manufacturer and of required shade and colour all complete to
achieve even shade and colour :
New work (two or more coats) over and including water
thinnable priming coat with cement primer having VOC content
less than 50 gram/litre sqm 185.65 130.12 24,156.00
36 13.5 Finishing walls with textured exterior paint of required shade :
New work (Two or more coats applied @ 3.28 ltr/10 sqm)
over and including priming coat of exterior primer applied @
37 13.80 Providing and applying white cement based putty of average thickness 1
mm, of approved brand and manufacturer, over the plastered wall surface
to prepare the surface even and smooth complete. sqm 156.05 92.25 14,396.00
38 DSR 13.47 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required
38.1 13.47.1 New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of
exterior primer applied @ 2.20 kg/ 10 sqm) sqm 171.10 92.25 15,784.00
39 13.61 Painting with synthetic enamel paint of approved brand and manufacture to give an even
13.61.1 Two or more coats on new work sqm 155.90 42.85 6,681.00
Digitally signed by PRIYA
40 MR-9 Supply Fitting and fixing 6 to 12 inch height 306 grade stainless steel 18 gauge letter cut with
Leaser machine as per the design LETTER PROJECTION - 2 Inch projected with 18 gauge
thick steel sheet to make the side wall of letter (6 to12 inch)
41 MR-10 Providing and fixing 3D Stainless Steel Golden Letter Signage and Logo Grade 306
Stainless Steel, laser cut, fabricated, polished to chrome/mirror finish, including 3M vinyl
graphics printed on HP Latex machine with over-lamination on logo, complete with 60–75
mm projection, stainless steel studs, fixing accessories, transportation, erection and
installation on existing wall, complete as per approved design and direction of Engineer-in-
Total-A+B 17,21,035.00
Digitally signed by PRIYA
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
detail.html
html • 0.06 MB
1 NIT 204 KV Barkatha.pdf
Tender Document
3 SCC Barkatha.pdf
Tender Document
4 Scope of work.pdf
Tender Document
5 Soil Report.pdf
Tender Document
6 Drawings.pdf
Tender Document
7 Technical Circulars upto 36.pdf
Tender Document
8 GCC With Ammendment 05.pdf
Tender Document
9 List of Approved Makex KVS.pdf
Tender Document
10 IP.pdf
Tender Document
2 BOQ.pdf
Tender Document
addendum-179f4b3d5fdb-Corri-01 2040.pdf
pdf • 0.14 MB
corrigendum-5823-Corri-01 204.pdf
pdf • 0.14 MB
addendum-7ca372b03ec0-10 IP.pdf
pdf • 0.83 MB
addendum-250218e09ba1-3 SCC KVSB.pdf
pdf • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .