Operation and Maintenance of Water treatment plant, Repairs to over head tank and Sump for the Year 2026-27.
KBJNL/2026-27/WS/WORK_INDENT3775
KBJNL/2026-27/WS/WORK_INDENT3775
Open
Water supply/sewage lines
Two Tender Document System(Two Cover)
KBJNL Division Dam Division Almatti
10 documents required · 10 mandatory
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
List of Financial Resources with Certificates
The intending bidders should be a registered contractor enrolled in valid KPWD Class-II & above contractor licence along with labour licence (Form-C)
Valid Employees Provident Fund Registration Certificate
Valid ESI Registration Certificate
Valid GST Registration Certificate mandatory
To qualify for award of this contract, each Tenderer in its name should have in the last five years i.e.,2021-22, 2022-23, 2023-24, 2024-25& 2025-26.The intending bidder in his/its name should have in the last 5 years i.e,2021-22 to 2025-26 achieved in at least 2 financial years, a Minimum financial turn over of Rs. 215.96 Lakhs.(usually not less than two times the estimated annual payments under this contract).The turnover prior to FY 2025-26 will be updated to the Present Price Level by giving weight age of 10% each year. Audited Profit and Loss account certified by a practicing Chartered Accountant bearing UDIN along with copy of Income Tax returns filed for the years indicated above should be furnished. FY 2026-27
The intending bidder should have in last 5 years i.e. from 2021-22 to 2025-26, Satisfactorily completed (not less than 90% of the contract value), as prime contractor, one similar work Operation and maintenance/AME/Construction of new drinking water treatment plant costing not less Rs. 54.00 lakhs (50% of the amount put to tender) in last five years reckoned back from 2025-26)(Up to last date of submission bid) (The work done certificate should be obtained duly signed from an officer not below the rank of Executive Engineer of the concerned Division. The cost will be updated to the present value by giving a weightage of 10% each year.)if the work is completed prior to FY 2026-27
The intending bidder should have in last 5 years i.e. from 2021-22 to 2025-26, The intending bidder should have executed minimum quantity of work (0.80XQtyX12/12 Months) in any one financial year, during the last five financial years reckoned from 2025-26. Of (1) Providing Manpower is equals to 10 Months, 13 labour /Month, (2) Waterproofing work is equals to 801.60 Sqm, (3) Providing & Fixing of new/replacement of filter media in WTP is equals to 1.5 MLD & above. The work done certificate should be obtained duly signed from an officer not below the rank of Executive Engineer of the concerned Division.
Bidder should furnish liquid assets and/or availability of credit facilities of not less than Rs.27.00 Lakhs from any Nationalized /scheduled bank (Credit lines/letter of credit/certificates from banks for meeting the fund requirement etc. (Usually the equivalent of the estimated cash flow for 3 months in the peak construction period)). The format for Bankers Certificate / Line of Credit (BC/LOC) letter to be issued by the Banks as per circular No. FD-CAM/16/2022(P-2) dated: 22-08-2022.
Tenderers who meet the above specified minimum qualification criteria, will only be qualified, if their available tender capacity is more than the total tender value (Rs.107.96 Lakhs).The available tender Capacity will be calculated as under Assessed available tender Capacity is (AXNX1.5 - B), where, A is Maximum value of civil engineering works Executed in any one year during the last five years (updated to 2026-27 price level) taking into account the completed as well as works in progress. N is Number of years (1 years i.e.12Months )prescribed for completion of the works for which tenders are invited. B is Value, at 2026-27 price level, of existing commitments and on going works to be completed during the next 12 months (Period of completion of the works for which tenders are invited)
The Requisite EarestMoneyDepositein(E-cash)
₹2,700
₹1.6 L
10 Sept 2026
10 Sept 2026
24 Sept 2026
16 Sept 2026
17 Sept 2026
Operation and Maintenance of Water treatment plant, Repairs to over head tank and Sump for the Year 2026-27. Daily Consumable material for old and New IB and Chumari Block For the Year 2026-27
Sl No DETAILED SPECIFICAITONS Quantity UNIT Ref. for detail specifications AMOUNT
In figures In words
SUB ESTIMATE-1 (LABOUR COMPONENT)
Operation and maintenance of intake ,jack well, raw water pump house and water treatment plant having capacity 0.35 MGD at Almatti colony which includes all components like aerator,chemical house, laborotry,filter house and pump house etc, including MS rising main and gravity main of 200mm dia from pump house at jack well to end point of Service reservoirs for length of 1.20 kms and 150 mm dia to 75 mm dia for gravity main for 1.20 kms and Distribution net work for a length of 6.50 kms having 20 mm to25mm dia CI/DI/MS/GI Pipes including supplying of treated water to door step and operation and maintenance of pumps, including routine and preventive maintenance as per operation manual/recommendation. It also includes operation and consumables like Alum/PAC powder, Clorine,Bleaching powder and other chemicals, as per standards and daily testing of water in laboratory watch and ward of jack well, water treatment plant raising and gravity main including distribution pipeline network, maintenance of specials and valves on pipeline network. This operation and maintenance includes coverage of risk/other hazzards materials and consumables. Operational staff/maintenance staff and patroling of pipeline along the alignment and all woris and conditions as defined in various clauses of tender document excluding the major repairs of pumps and panel boards etc., complete as directed by the Engineer-in-charge of the work.For this Engaging following personnels per day as mentioned below.
1 Pump operator (Skilled) 36 Months 29532.87 1,063,183.29
2 Electrician ( Licensed ) (Skilled) 12 Months 29532.87 354,394.43
3 Valveman (Unskilled) 60 Months 24623.81 1,477,428.88
4 Light mazdoor (Unskilled) 12 Months 24623.81 295,485.78
5 Watchman (Unskilled) 36 Months 24623.81 886,457.33
SUB ESTIMATE-2 (CHEMICAL AND CONSUMABLES ITEMS)
6 Providing and supplying of bleaching powder Grade-II snow white colour through 100 MASH containing stable chlorine C-12 @ 32% including all taxes loading, unloading and transportation up to water treatment plant at Almatti calony and making arrangements of weighing at your own cost etc., complete as As directed by the Engineer-in-charge of the work. 1,596.97 Kg 41.50 66,274.26
7 Providing and supplying of Sulphate of Ferric Alum Grade-II loose slabs of cream colour Alumina as A-1203 @ 15% IRON as Fe at 0.5% and INSOLUBLES at 1.00% including all taxes loading, unloading and transportation up to water treatment plant at Almatti Calony and making arrangements of weighing at your own cost etc., complete as As directed by the Engineer-in-charge of the work. 16,108.88 Kg 14.30 230,356.98
8 Providing and supplying of Liquid Chlorine containing percentage of C-12 @ 98% to 99% Oxygen @ 0.80% Cylinder of capacity 900 Kg filled in own Cylinder as per ISI specifications on cylinder returnable bases including all taxes loading, unloading and transportation up to water treatment plant at Almatti calony and making arrangements of weighing at your own cost etc., complete as As directed by the Engineer-in-charge of the work. 871.07 Kg 49.00 42,682.43
10 Providing and supplying of Grease including all taxes loading, unloading and transportation up to water treatment plant at Almatti camp, complete as As directed by the Engineer-in-charge of the work. 25.40 Kg 189.00 4,800.60
11 Wire brush 90.00 Each 45.00 4,050.00
12 Rubber Packing 10.00 Kg 199.00 1,990.00
SUB ESTIMATE-3 (Garden Maintenance)
13 Work to be Under Taken During Maintenance of garden (i)Watering: the plants and lawns in the garden should be watered frequently as required looking to the climate, soil and plant conditions. If Sprinklers are made availbale it can be used other wise hose pipe can be used for watering problems regarding pipeline damage during watering/ maintenance should be repaired and taken care. (ii) Weeding:-Weeding has to be done reguraly in the entire garden area including extra weed growth in the pathways and other remaining areas in the park. Weeding should be done reguraly once in a fortnight and the weeds collected should be used for preparing manure or it should be disposed from the garden appropriately. (iii) Sweeping:-Sweeping of the garden area has to be done daily. The pathways entire garden area should be swept and kept free of fallen leanves branches ,flowers, dusts, etc. and should be made for the public. Dust bins in the garden area should be emptied and disposed propperly and reguraly. Any dead rodent pets or animals area founds should be removed immediately and the garden spaces should be free from foul smell. Gezeboo, Chairs and other Adomments shouldbe be cleaned daily. (iv) Maintenance of shrubs, Hedges, Ground covers and other area by reguraly pruning so as to maintain the garden aesthetically. (v) Lawn mowing should be done reguraly every fortnight. (vi) Digging of soil around plants in the garden, should be carried out. Soil basins should be prepared around the Hedges/edge/trees/shrubs/ground covers by digging the soil so as to maintain retention of water. This should be done before and after monsoon. (vii) Pruning of plants in the garden, such as the hedges, Trees, Shrubs, Ground Cover plants Topiary plants Rose plants, etc should be carried out as and when required. (viii) Transportation of plastic and other materials should be removed from the garden, must be taken care. The swept leaf materials only should be used for preparation of compost manure in the garden itself and the compost manure should be used in the garden. All dead plants, branches, and other waste materials should be removed regularly and transported outside the garden. In the garden area dried leaves and other waste materials should be regularly removed from the garden at the risk of contractors. (ix) Garden Labour accommodation and any other accidetns, is soley responsible of contractor. And all other works to be done as per the direction of the officer incharge and to the satisfaction of the officer incharge. 15,000.00 Sqm 6.00 90,000.00
14 Lawn Bed Maintenance (Chemicals):-Procuring of Insecticide (Termite Control) Procuring Chlorophyriphos Liquid drenching @ 5mL/liter of water for 5 Sqm of Lawn once in a year. 1.25 Ltr 286.00 357.50
15 Procuring of Biofertilizer/ Neem cake/Neem powder @200 Kg/Acre Soil Application. Once in a year. 35.00 Kg 18.00 630.00
16 Procuring of Fungicide sulpher 50% W.P @ 20gm/15 ltr tank. 1 tank per 100 Sqm of Ground Cover/Flower Bed Each time. Foliar Application once in a year. 0.25 Kg 400.00 100.00
SUB ESTIMATE-4 (Water proofing to OHT,GLSR, Aerator, Falsh Mixer, Clariflocculator and Providing Required Valves )
17 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of Engineer-in-charge. 1,001.59 Sqm 38.85 38,911.92
18 Retaining Wall (Inside) / OHT / UG Sump Tanks. Providing & Applying Crystalline waterproofing slurry coat RCC structure like Retaining wall, Underground tank. The material having chemical resistance properties, seals shrinkage cracks up to 0.4 mm width, capable of preventing water dampness & seepages, Water permeability is Nil confirms to BS EN 12390 Part 8: 2000. Powder to water mixed at a ratio (5:2) 5 parts powder and 2 parts water, applied @ 1.5kg/m2 in 2 coats to achieve 1.0mm DFT on a cleaned surface free from all loose materials etc., complete. The finished cost to include surface preparation completely as per specification. 1,001.59 Sqm 2,572.50 2,576,599.79
19 Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete For sluice Valve of PN 16.0 and 200mm 4.00 Each 34,687.80 138,751.20
20 Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete For sluice Valve of PN 16.0 and 250mm 3.00 Each 54,313.35 162,940.05
21 Providing, fabricaing and fixing at site various diameters of MS Flanges as per IS standards to fix sluice valves as per sketch. The rate to include cost of all materials, labour, consumables, hire charges for tools and tackles, weldiing equipments etc. complete as per instructions of the Engineer in charge for: Flanges of 200mm dia and 16mm thick. 8.00 Each 2,363.55 18,908.40
22 Providing, fabricaing and fixing at site various diameters of MS Flanges as per IS standards to fix sluice valves as per sketch. The rate to include cost of all materials, labour, consumables, hire charges for tools and tackles, weldiing equipments etc. complete as per instructions of the Engineer in charge for: Flanges of 250mm dia and 16mm thick. 4.00 Each 3,123.75 12,495.00
23 Manufacturing, providing, trasporting, rolling, lowering, laying, jointing and commissioning of ERW (Electric Resistance Welded)/ SAW (Submerged Arc Welded) MS pipes of Outer dia (Fe-410 grade) conforming to IS 3589-2001 with latest amendments, including perfect linking and welding of joints to correct position, cost of the pipes, conveyance, lead, lift charges, cost of all labour and giving satisfactory hydraulic test as per IS 3589-2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications inside with CM 1:1.5 lining of minimum 10mm thick for pipes upto 610mm OD and with minimum 12mm thick beyond 610mm OD and out side with minimum 25mm thick coating in CM 1:3 over 50 x 50mm weld mesh of 13 gauge, including loading and unloading of pipes for the following diameters and specified thickness of plate as noted below, including bailing out of water wherever necessary. (Contractor will make his own arrangements for procuring water for testing). For MS Pipes of 219mm dia Note: a) No Negative tolerance in respect of thickness is pemissible. b) Basic Cost of MS Plate is considered as Rs.71,700/- per MT c) The pipe costs are FOR destination anywhere in Karnataka. Pipe of 219mm dia 6.0mm thick 24.50 mtr 4,446.75 108,945.38
SUB ESTIMATE-5 (Replacement of filter media and Electromechanical Components)
24 Removing the existing filter media of course and fine aggregate from rapid gravity beds including cleaning the filter chamber and disposing off removed media outside of the filter house all lead and lifts as directed by the Engineering in charge. 32.40 Cum 1750 56,700.00
25 Attending minor repairs to RCC Manifold and plastering the manifold top and sides with cement mortar 1:3 with water proof compound as directed by the Engineer in charge 2.00 Job 30000 60,000.00
26 Cleaning of filter beds and guller walls and filter side walls with jet machine including all cost of labors machines and etc.Complete. 2.00 Job 18000 36,000.00
27 Supplying of rapid gravity filter media of sand effective size 0.40 to 0.60 mm and UC between 1.30 to 1.70 the Rates inclusive of Transportation,and stacking Media at water Treatment plant site yard as directed by the Engineer in charge. 17.56 Cum 25000 439,000.00
28 Supply of course sand of size 2mm to 6mm as per PHE manual.The rates inclusive of Transportation and stacking Media at W.T.P.Yard as directed by Engineer in Charge. 4.06 Cum 20000 81,200.00
29 Supply of course pebbles of size 6mm to 60mm per PHE manual.The rates inclusive of Transportation and stacking Media at W.T.P.Yard as directed by Engineer in Charge. 5.35 Cum 18000 96,228.00
30 Refilling the newly and existing supplied filter media in proper depth by manual mean by head load conveyance carefully in specified sizes layer by layer uniformly with all lead and lifts & as directed by the Engineer in Charge. 32.40 Cum 1750 56,700.00
31 Supplying and Fixing Non Return Valve 100 MMDia 2.00 No 12500 25,000.00
32 Fabrication of Manifold pipe by Providing (T-Section) and other suitable dia MS Pipes including perfect linking by gas cutting and welding etc complete with satisyfactory hydraulic test including all lead and lift and labour charges 1.00 Job 40000 40,000.00
33 Re-Conditioning of Alum Mixing plant and making suitable arrangements and connecteions to supply alum for Flash Mixer tank etc complete. 1.00 Job 15000 15,000.00
34 Supplying and Fixing of pressure gauge meter Silcagel glysirine filled along with all fittings etc complete. 4.00 Set 8500 34,000.00
35 Dismantling Overhauling and servicing of Existing motor and its arrangements at flash mixerincluding supply of matrials, labour, errection charges with all lead and lift etc complete. 1.00 Job 15000 15,000.00
36 Dismantling, Overhauling and servicing of Clariflocculator motors and Reconditioning of Rotating Mounted Bridge including cunsumable items with all labour charges, lead and lift complete 1.00 Job 60000 60,000.00
37 Supply and fixing of Gear Box along with all accessories including all labour charges, lead and lift complete complet etc,. 8.00 Each 18500 148,000.00
38 Supplying, fabricating errecting of Stainless steel to Flash Mixer rod and its paddles, Clarifier rod and its paddles, Floccculator rod and its paddles. fabricated from Rolled stainless steel section like channels/ angle/ beams/rails/ plates etc,. Asper specification and approved drawings including cost of all materials machinary, labour,scaffolding, Cleaning, cutting welding, Grinding, errecting including all labour charges, lead and lift complete complet etc,. 1.00 Job 575000 575,000.00
39 Supply of regent kits for awter quality testing using field test kit (FTKS at GP Level) 2.00 Set 7850 15,700.00
40 Re-Conditioning of existing ISMB200 Gurder Beam including Spur geared Indef Make Chain Pully Block with 6m lifting chain to the existing pump house suitable to carry gantry to take up the load of 2MT Complete etc,. 1.00 Job 34000 34,000.00
41 Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments.2 HP, Size 65x50 Head 13M, Discharge 462 LPM 3.00 Each 16390.5 49,171.50
42 Supply and delivery of Centrifugal pumpset 15 HP, size 80x65 Head 44M, Discharge 900 LPM at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments 2.00 Each 56665.35 113,330.70
43 Supply and delivery at site brand new best make starter/ control panel suitable for following HP centrifugal pump confirming with ISI mark and its latest amendments 10 to 12 HP centrifugal pump 2.00 Each 37432.5 74,865.00
44 Work of supply and fixing of 40 amps star delta panel Boards upto 15Hp backwash pump motor as specified below: a. Supply and fixing of new upto 15 Hp star delta starter panel board for back wash motor with the following materials. b. Power connector upto 40 A. c. On delay, off delay automatic timer. d. Over current relay upto 20-60 amps e. Upto 10 amps MCB 3 Pole for control circuit. f. Contactor 2 No+ 2 Nc upto 25 amps g. Single phase preventer. h. On and off push button switch. i. LED indication lamps RYB motor on, off and trip. j. 0 to 600 volts meter upto 96/96 mm. k. Amps meter C.T Ratio upto 100/5A. l. Current Transformer for metering upto 100/5A. m. upto 30mmx10mm Electronic Grad Aluminum bus bar for RYB phases. n. Internal main wiring using upto 95 sq.mm Copper wire. o. Volts and ammeter selector switch 2.00 Each 35413.35 70,826.70
45 Supply, installation and commissioning of Chlorine Di Oxide Generator and confirming the specification as per below.Application of ClO2 Generator: 1) For disinfection ClO2 dosage required between 0.2-0.3ppm or mg/litre and for disinfection chemical has to dilute at site using RO water or DM water. 2) For removal of dissolved algea and green color from the raw water 0.68-1ppm or mg/litre dosage is required. For the capacity from 10000lph to 450000lph The Requirment of Chemicals Refer ANNEXURE-E ClO2 generator Capacity 200-1000 gm/hr Input power 230 V a/c, 50Hz Water pressure Inlet 2.5±0.5 Kg/cm2 Outlet 2.5±0.5 Kg/cm2 Pressure drop ~ 0.5 Kg/cm2 Operating Temperature Minimum 25 Deg C Maximum 40 Deg C Dosing Pump for 1496 0 to 10 lph Dosing Pump for HCL 0 to 10 lph Electrical Control Panel 1 no Drive water pump Capacity 200-1000 litre/hr Head 25 m MOC CI 1.00 Set 614250 614,250.00
46 1.1kV LTUG Heat Resistant PVC Insulated Cables as per IS-1554 (Part-1) 1998 with following parameters & as per BESCOM Requirements: • H2/H4 grade Aluminium Conductor having purity of 99.7% • Conductor Resistivity of 0.028264 Ωmm²/m • Insulated through extrusion with HR PVC Compound • HR PVC compound Insulation withstanding temparature of 85 Deg C should pass minimum Thermal Stability of 100 Minutes as per IS-5831-1984 Type C • Extruded inner sheath PVC ST-2 compound • GI strip armoured (hot dip galvanized armour width and thickness in average tolerance of ± 5%, resistivity 14.5 Ω/ Km maximum as per IS-3975 and armour coverage should be minimum 90%) (No of aromour wires shall be as per below table) • Outer sheath extruded ST2 PVC compound should pass thermal stability minimum value of 100 minutes conforming to IS-7098 (PART 1) – 2011 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm) 0.20 Km 219446.4 43,889.28
47 Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 Sqmm 0.20 Km 22329.6 4,465.92
48 Supply of LED Street light luminaire with pressure diecast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @Lumen Maintenance of 70%, maximum light intensity should be between 60degrees to 70degrees. CCT>5500K, IP66 optical and electrical compartment &impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection-Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm.Universal Voltage driver too perate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC60598,LM79& LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........WSystem Power consumption. LED Efficiency>1301m/w, nominal CRI >75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO9001:2008. Housing with supplier wordmark/name shallbe Engraved /Embossing on the diecast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 200 W 5.00 Each 19094 95,470.00
49 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2 200.00 Mtr 42 8,400.00
50 Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia 3.00 No 3510 10,530.00
51 Supplying and fixing of GI/Copper strips for grounding connections, using necessary fixing materials as required.25 x 3 mm GI strip 30 mtr 82 2,460.00
"Supply and Errection 12.5Mtr High Mast Pole at WTP" 0.00
52 Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m 9.68 cum 107.1 1,036.73
53 Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes ma chine mixed, laid in layers not exceeding 150 mm thickness, well com pacted using plate vibrators, including all lead & lifts, cost of all materi als of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates 0.5808 Cum 6454.35 3,748.69
54 Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates 2.187 Cum 6853.35 14,988.28
55 Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification for buildling. 0.09906 Tonne 94987.2 9,409.43
56 5 Fabrication, Supplying, Erection, Testing and Commissioning of 12 m/12.5 m - Top 100 mm and Bottom 310 mm dia ms long Polygon high mast with Single/Multiple telescopic sections having, (minimum overlap distance of 1.5 times of top section) thickness as per BSEN 10025 grades 355 JO/ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/s as per IS 875 part 3(as per GA Drawing). Base plate as per IS 2062/ASTM A572-50. The mast shall be Galvanized in single Hotdip as per BSEN ISO 1461/ASTM A123 with an average 70 microns as per IS 2629, and welded as per BS 5135 Single L-Seam joint The mast shall have 2 Way head frame with die cast LM-6 pulleys, stainless steel axle, Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5 mm dia, stainless steel wire rope of AISI 304grade 7/19-core, (Factor of Safety as per TR no-7). 2.5 mm2 EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement The mast shall have manual/power tool (Suitable reversible geared motor operating on 230/415V, 50Hz, shall be provide above 15 Mtr mast) The mast shall have lantern of 2 segments, suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3 mm thick template, lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin l A fitting with wiring complete. (excluding foundation) as per technical data. 1 Each 131000 131,000.00
57 Supplying, and fixing of Single Arm Bracket with 1000 mm Standard 40/50 mm dia Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. 1 Each 1700 1,700.00
58 Supply of LED 150w floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT > 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency> 1301m/w, nominal CRI >75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved /Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 8 Each 12490 99,920.00
59 Fixing charges of post top/ Gate/ Garden fitting /LED on the existing CI / GI or any other pipe using required size of reducer, wiring using suitable wires. complete as per direction of engineer in charge. 8 Each 198 1,584.00
60 Supplying and drawing 3C X 2.5Sq.mm Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS:8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage up to 1100Volts as per IS-694:1990 50 Mtr 113 5,650.00
61 Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In Ordinary Soil 100 cum 260 26,000.00
62 Fabricating supplying and mounting MS box made out 14 SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete.complete as per direction of engineer in charge. 45000 Sq.Cms 0.5 22,500.00
63 Supplying 100Amps 4x30x6mm Aluminum Strips rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.complete as per direction of engineer in charge. 2 Mtr 2465 4,930.00
64 Supplying and fixing 40x40x6mm angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.complete as per direction of engineer in charge. 5 Mtr 305 1,525.00
65 Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.complete as per direction of engineer in charge. 1 Each 9315 9,315.00
66 Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C.complete as per direction of engineer in charge. 3 Each 515 1,545.00
67 Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers.complete as per direction of engineer in charge. 1 Each 4843 4,843.00
68 Supplying and fixing 6-32Amps TPN miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.complete as per direction of engineer in charge. 2 Each 1717 3,434.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
WTP.pdf
Others - Drawings • 0.48 MB
WTP Plan-Model.pdf
Others - Drawings • 0.14 MB
DTP WTP.docx
Tender Document • 21.51 MB
WTP Sch B.xlsx
Others - Schedule B • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .