| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-AOC BUNGALOW NO 21 CANTONMENT BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | ₹24.8 L Quoted ₹26.8 L | L1 | Accepted-AOC 1ST LOWEST |
| 2 | L2₹27.8 L+₹1.0 L (3.84%)Rejected-Finance WARD NO 11 THIRIYA NIZAWAT KHAN BAREILLY | BAREILLY | BAREILLY | ₹27.8 L+₹1.0 L (3.84%) | L2 | Rejected-Finance 2ND LOWEST |
| 3 | L3₹32.9 L+₹6.2 L (23.0%)Rejected-Finance | ₹32.9 L+₹6.2 L (23.0%) | L3 | Rejected-Finance 3RD LOWEST |
| 4 | L4₹39.0 L+₹12.3 L (45.8%)Rejected-Finance | ₹39.0 L+₹12.3 L (45.8%) | L4 | Rejected-Finance 4TH LOWEST |
| 5 | L5₹39.1 L+₹12.3 L (46.0%)Rejected-Finance SHOP NO 10 ASHRAM MANDIR NAKATIA P O P A C SHAHJAHANPUR ROAD BAREILLY 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | ₹39.1 L+₹12.3 L (46.0%) | L5 | Rejected-Finance 5TH LOWEST |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
21 Aug 2021, 6:00 pmClosed
(Vidhi A Raut, IDSE)
Military Engineer Services Shahjahanpur Garrison Engineer East Military Road Bareilly Cantt
REPAIRS MAINT OF SUB MAIN WIRING DBS AND CONNECTED WORK BLDG. SECURITY LIGHT REPAIR MAINT OF CEILING FANS EXHAUST FAN AIR CIRCULATOR PVC EXHAUST FANS AND GEYSERS ETC UNDER GE E BAREILLY
2021_MES_461547_1
C/8937/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE EAST BAREILLY
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE EAST BAREILLY
₹86,000
Yes
20 Sept 2021
20 Jul 2021
23 Aug 2021
20 Jul 2021
21 Aug 2021
9 Aug 2021
20 Jul 2021 - 5 Aug 2021
Amount
Taking down electric meter and disconnecting, removing to store for keeping in safe custody for refixing etc complete all as specified & as directed.
Taking down main switch / MCB/ DBS including MC BS etc of any size removing for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surfaces to match with the existing surfaces of wall, floors etc complete all as specified and directed.
Taking dowm submainwiring including earth wire and making good disturbed surfaces to match with the existing surfaces of walls incuding removing from site for credit complete all as specified and directed.
Taking down copper/aluminum point wiring complete including fixture and fitting such as switches, ceiling roses, light fitting etc, removing materials for taking credit (credit for the items should be made as per conditions separately ) and making good disturbed surfaces of wall, floors etc complete all as specified & as directed.
M & L for point wiring with 2.5 sqmm cable PVC unsheathed and insulated copper multistranded conductor FRLS 1100 Volts grade cable ( red colour cable to be used for live connection and black colour cable to be used for neutral connection ) controlled by one way switch drown through and including non metallic rigid PVC concealed conduit with all accessories and 2.5 sqmm copper multistrand conductor FRLS 1100 Volts grade unsheathed PVC insulated ( green colour ) continuity earth wire connected to common earth dolly and sunk cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of switch with 3 mm thick hylum laminated sheet cover incl cutting Chases pinning in, for concealed conduit wiring and making goods of disturbed surface not exc 15 cm girth complete all as specified and as directed for more than one light controlled by one Switch complete all as specified & as directed.
S&F Switch Piano flush type single pole one way 15 Amps complete all as specified & as directed.
S&F ceiling roze, 3 terminals, PVC polycarbonate isolated body complete all as specified & as directed.
Fixing only and connecting electric meter upto 25 Amps, received against item srl no-1 above complete all as specified & as directed.
M & L for sub main wiring with 2 run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through in PVC conduit/ PVC Casing & Caping complete all as specified and directed. (Note- 2 Run of wire +1 run of Earth wire+ 1 run of PVC conduit/casing&capping will be measured as one unit.)
M & L for sub main wiring with 2 run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through in existing PVC conduit/ PVC Casing & Caping complete all as specified and directed. (Note- 2 Run of wire +1 run of Earth wire+ 1 run of PVC conduit/casing&capping will be measured as one unit.)
M & L for sub main wiring with 2 run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through in PVC conduit/ PVC Casing & Caping complete all as specified and directed. (Note- 2 Run of wire +1 run of Earth wire+ 1 run of PVC conduit/casing&capping will be measured as one unit.)
M & L for sub main wiring with 2 run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through in existing PVC conduit/ PVC Casing & Caping complete all as specified and directed. (Note- 2 Run of wire +1 run of Earth wire+ 1 run of PVC conduit/casing&capping will be measured as one unit.)
M & L for sub main wiring with 2 run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through in PVC conduit/ PVC Casing & Caping complete all as specified and directed. Note- 2 Run of wire +1 run of Earth wire+ 1 run of PVC conduit/casing&capping will be measured as one unit.
M & L for sub main wiring with 2 run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through in existing PVC conduit/ PVC Casing & Caping complete all as specified and directed. (Note- 2 Run of wire +1 run of Earth wire+ 1 run of PVC conduit/casing&capping will be measured as one unit.)
S&F sheet metal enclousers (DBS) when MCBs to be used 4 way, 240 Volts, double door, Single pole & neutral prewired made out of CRCA sheet with 1.6mm thick, with 200 Amps rated bus bar.(MCBs are to be measured and paid for seperately) complete all as specified and directed
S&F sheet metal enclousers (DBS) when MCBs to be used 8 way, 240 Volts, double door, single pole & neutral prewired made out of CRCA sheet with 1.6mm thick, with 200 Amps rated bus bar.(MCBs are to be measured and paid for seperately) complete all as specified and directed
S&F sheet metal enclousers (DBS) when MCBs to be used 12 way, 240 Volts, double door, single pole & neutral prewired made out of CRCA sheet with 1.6mm thick, with 200 Amps rated bus bar.(MCBs are to be measured and paid for seperately) complete all as specified and directed
S&F sheet metal enclousers (DBS) when MCBs to be used 4way, 415 Volts, double door, three phase & neutral prewired made out of CRCA sheet with 1.6mm thick, with 200 Amps rated bus bar.(MCBs are to be measured and paid for seperately) complete all as specified and directed
S&F MCB TPN 100 A, 415V, 10 KA, B curve type complete all as specified & directed.
S&F MCB SPN 16 to 63 A, 230 V, 10 KA, B curve type complete all as specified & directed.
Fixing only MCB 16A - 63A, 230 Volt, 10 KA, complete ( Received from item No- 2 above ) complete all as specified and directed
S&F MCB SP 6 A- 32A, 230 V, 10 KA, B curve type complete all as specified & directed.
Fixing only MCB SP 6A - 32A , 230V, 10KA, B' curve type complete all as specified and directed
S & F in repairs MCCB 100A, 415 Volts, 4 pole 16KA complete all as specified and directed
S&F Blanking plate PVC complete all as specified and directed
S & F in repairs GI bracket made out from GI pipe 25/32mm dia, 1.20 m long fixed on wall with and including nut, bolts and GI clamps of size 25x4mm as required & including painting etc complete.
S & F in repairs LED building security light fitting 25 Watt 230 Volts AC out door type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket and corrision resistant including thermal management in multiple optics complete IP 65/66 protection including electric connections etc complete all as specified & directed.
S & F in repairs LED building security light fitting 35 Watt 230 Volts AC out door type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket and corrision resistant including thermal management in multiple optics complete IP 65/66 protection including electric conection complete all as specified & directed.
M & L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metres below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts,check nuts, nuts and washers of GI or steel all as shown in electrical plate No 3 of SSR-I 2009. GI wire protected by GI pipe light grade 15mm dia connected to earth test point including excavation in any type of soil, returning filling, disposal of soil, earthing pit in PCC (1:3:6) type C1,RCC (1:2:4) type B1 precast cover slab with one handle made out of 8 mm dia round bar,20 mm dia (medium grade) watering pipe and providing layer of charcoal or coke and salt in alternative layers complete as specified or directed & including testng on completion.
Taking down Ceilings/Walls/AirCirculator and refixing the same after repairs/painting in original position including fixing of nut, bolt & split pin and provision of new three core flexible PVC insulated multistranded copper conductor cable 1.0 sqmm from ceiling rose to fan complete all as specified and directed by Engr-in-charge.(Note- Repair work/ painting and cable for connection shall be measured and paid separately )
All as per item no. 30 (here in before) but Exhaust fans of any sweep complete as specified or directed
M&L for dismantiling the ceiling fan of any sweep/wall mounted fan/Air circulator fan , cleaning the surfaces throughly and applying a spray coat of synthetic existing enamel paint over one coat of red oxide primer including rewriting MES no. on fan complete all as specified and directed by Engr-in-Charge.
All as per item no 32 .( here in before) but Exhaust fans of any sweep.
M&L for dismentiling the Stator & Rotor of ceiling fan of any sweep,taking out the burnt copper wire, cleaning the Stator & Rotor with CTC, rewinding the fan with existing gauge and same nos of turns with super enameled copper including varnishing, baking, replacement of sleeves etc and reassembling the fan & testing , complete all as specified and directed by Engr-in-Charge.
All as per item no.34 (here in before) but Exhaust fan of 300mm sweep complete all as specified & directed.
All as per item no.34 (here in before) but Exhaust fan of 375/450mm sweep complete all as specified & directed.
All as per item no.34 (here in before) but Wall mounted fans complete all as specified & directed.
Dismantiling the ceiling fan of any sweep, examine complete part thoroughly , oiling, greasingall parts and complete overhauling of fan including replacement of spares such as bearings, bushes, split pin, nuts, bollts, clamps, screws and reassembling complete fan and making fully functional coplete all as specified and directed by Engr-in-Charge. [Note:- Spares like Bearings, Bushes, Capacitor & others shall be measured and paid separetely.]
All as per item no.38 (here in before) but Exhaust fans of any sweep complete all as specified & directed.
All as per item no.38 (here in before) but Wall mounted fans complete all as specified & directed.
All as per item no.38 (here in before) but Air Circulator fans complete all as specified & directed.
. Supply & Fix in repairs metal bush made out of Gun metal/Brass suitable for ceiling fans/ Exhaust fans of anysweep.
Supply& fix in repairs ball bearings suitable for ceiling fan of any sweep complete all as specified & directed.
Supply & fix in repairs ball bearings suitable for Exhaust fan of any sweep complete all as specified & directed.
Supply & fix in repairs capacitor 2.5 Mfd, 415 , 50Hz. Make- Universal/Tibcon or equivalent as approved by GE.
Supply & fix in repairs capacitor wall mounted fan 2.0 Mfd, 415V, 50Hz Make- Universal/Tibcon or equivalent as approved by GE.
Supply & fix in repairs capacitor 3.15/4.0 Mfd, 415 V,50Hz Make- Universal/Tibocon or equivalent as approved by GE.
Supply & Fix in repairs fan hook clamps steel suitable for ceiling fan hanging complete all as specified & directed
Supply & fix in repairs rubber reel for ceiling fan hanging complete all as specified & directed
Supply & Fix in repairs fan down rod made of 15 mm bore GI pipe, 60 cm long complete all as specified & directed.
Supply & Fix in repairs Canopy PVC suitable for fixing on fan down rod with screws etc complete all as specified & directed
Supply & Fix in repairs Fan blades complete with nuts & washers and complete all as specified & directed.
Supply & Fix fan hook steel with suitable nut bolts for fixing arrangement on GI Pipe for ceiling fan hanging complete all as specified & directed
Supply & Fix nut, bolt,washer and split pins suitable for fixing of fan clamps with down rod& hanging of ceiling fan complete all as specified & directed
Supply & Fix in replacement of burnt rotor assembly complete for 1200mm sweep ceiling fan all as specified and directed.
Supply &Fix in replacement of burnt stator assembly complete for 1200mm sweep ceiling fan all as specified and directed.
Supply & fix in repairs metalic Exhaust fan blade with MS frame for 300mm sweep Exhaust fan complete all as specified and directed.
Supply & fix in replacement of burnt motor kit for PVC Exhaust fan 250mm sweep complete all as specified and directed.
S&F stepped type electronic fan regulator switch, flush type on the existing phenolic laminated sheet ,180W, 250 Volts.complete all as specified and directed.
Supply & fix PVC insulated sheathed flexible multistranded copper conductor cable 3core 1.0 sqmm ,1100Volts grade complete all as specified and directed.
Disconnecting/Taking down from position existing defective storage type water heater( Geyser ) 25/35/50 Ltrs capacity of any make from the building carefully. Opening for repairing , replacement of defective inner, outer tank, deffective spares, accessories & packing with new glass wool, painting the same complete and reinstalling at its original position with suitable fastners etc, water cnnection, and electric connection with 3 core 1.5 sqmm copper cable, testing complete all as specified and directed by Engr-in-Charge. [Note:-Repair & replacement of item/ spares, painting works, electric copper cable and PVC connections etc for respective items, shall be measured and paid separately.
M&L for Geyser of 50/35/25Ltr capacity , cleaning the surfaces throughly and applying a spray coat of synthetic enamel paint including rewriting MES no. on Geyser complete all as specified and directed.
Supply &Fix in repairs steel outer body 50Ltr capacity complete all as specified and directed .
Supply &Fix in repairs steel outer body 25 Ltr capacity complete all as specified and directed .
Supply & Fix in repairs copper inner tank 50 Ltr capacity heavy quality complete all as specified and directed.
Supply & Fix in repairs copper inner tank 25 Ltr capacity heavy quality complete all as specified and directed.
Supply & Fix in replacement new apparatus plate/base heavy duty 18 SWG with rubber gasket suitable for 50/35/25 Ltr capacity Geysers complete all as specified and directed.
Supply & Fix in repairs Geyser assembly made out of copper for 50 Ltr capacity Geyser as per sample complete all as specified and directed.
Supply & Fix in repairs Geyser assembly made out of copper for 25 Ltr capacity Geyser as per sample complete all as specified and directed.
Taking down existing pressure release valve and Supply & Fix new pressure release valve with bent to Geyser as per ISI specification and directed.
Taking down existing safety valve and Supply & Fix new safety valve for Geyser as per ISI specification and directed.
Supply & Fix in repairs Geyser element 2.0 KW push type/thread type/dual clip type with rubber gasket suitable for Geyser of any size complete all as specified and directed. Make:- Bajaj/ Recold or equivalent as approved by GE.
Ditto All as per item no.72 above but 1.5KW of Make:- Bajaj/ Recold or equivalent as approved by GE.
Ditto All as per item no. 72 above but 1.5KW with thermostate pocket complete all as specified and directed
Ditto All as per item no 72 above but 1.5KW coiled type with porceline complete all as specified and directed
Supply &Fix in repairs thermostate switch ( ISI Marked ) suitable for Geyser 25/35/50 Ltr capacity, adjustable 0 degree to 80 degree centigrade and acting at 70 degree centigrade complete all as specified and directed
Supply &Fix in repairs new indicator lamp square type/round type, red/green colour for Geyser of any capacity complete all as specified and directed.
Repairs on existing inner copper tank by using brazing to make leak proof not exceeding 15 cm in length complete all as specified and directed.
Repairs on existing copper Geyser assembly by using brazing to make leak proof not exceeding 12 cm in length complete all as specified and directed.
Supply & Fix in repairs new PVC connection 15mm dia size of length 300mm long superior quality suitable to connect GI pipe 15mm dia to hot water outlet/cold water inlet of Geyser with brass adopter complete all as specified and directed. Make;-Prayag or equivalent as approved by GE.
Supply & Fix in repairs new PVC connection 15mm dia size of length 450mm long superior quality suitable to connect GI pipe 15mm dia to hot water outlet/cold water inlet of Geyser with brass adopter complete all as specified and directed. Make;-Prayag or equivalent as approved by GE..
Supply & Fix in repairs of sheet metal enclousers single pole & neutral with a two pin and earth plug and socket complete with double pole MCB 20A, 240Volt complete all as specified and directed Make:- Havells, HPL or equivalent as approved by GE.
S&F in repairs 3 pin 16 A plug top 230 Volts complete all as specified and directed.
Supply & fix in repairs PVC insulated sheathed flexible multistranded copper conductor cable 3 core 1.5 sqmm ,1100Volts grade complete all as specified and directed.
Supply & Fix in repairs Bib taps chromium plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule of size 15mm bore complete all as specified and directed.
Supply & Fix in repairs Stop valve chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule of size 15mm bore complete all as specified and directed. ( NOTE:- Tenderers may note that amount of credit will be deducted from the total amount arrived at the time of Acceptance of contract.)
N S ELECTRICALS
RAZA ENTERPRISES
LEEJA ENTERPRISES
NOORI ELECTRIC ENGINEERING WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .