Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.5 L+₹13,253 (2.10%)Rejected-Finance E 172 CHAURA MAIDAN 103 TUNNEL SHIMLA HIMACHAL PRADESH 171001 | SHIMLA | HIMACHAL PRADESH | 171001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹7.0 L+₹68,578 (10.8%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹5.6 L
EMD Value
₹11,200
Closing Date
22 Nov 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Elect. Division HPPWD Palampur
C/O Science lab (additional accommodation) for Govt. Sr. Sec. School at Lambagaon Lower, Tehsil Jaisinghpur, Distt. Kangra, HP (SH- Providing E.I. therein)
2021_PWD_53576_5
Elect. Division HPPWD Palampur
Open Tender
Electrical Works
Item Rate
365 days
Lambagaon in Tehsil Jaisinghpur
Please refer Tender documents.
10 documents required · 10 mandatory
₹350
₹11,200
4 Aug 2024
15 Nov 2021
23 Nov 2021
15 Nov 2021
22 Nov 2021
15 Nov 2021
120 days
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. (Make: KEI/ Polycab/ Finolex)
Group C.
Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 2-way, 5/6 amps. modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. (Make: KEI/ Polycab/ Finolex)
Group C.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. (Make: KEI/ Polycab/ Finolex)
2x2.5 Sq. mm.
2x4.0 Sq. mm.
2x10 Sq. mm.
Wiring for circuit / sub-main with 4x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.16 Sq.mm. (4x16+2x16) HRFRLS/PVC insulated single core copper conductor cable for earthing as required. (Make: KEI/ Polycab/ Finolex)
Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required. (Make: KEI/ Polycab/ Finolex)
PVC insulated HRFR LS Copper conductor 2.5 Sq. mm.
3x2.5 Sq. mm.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required. Make:- Legrand (Myrius)/ SSK(Lica)/ Anchor Roma (Plus)
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required. Make:- Legrand (Myrius)/ SSK(Lica)/ Anchor Roma (Plus)
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- Make: Legrand, L&T and Schneider
Single pole. Cat-A.( 6 Amps)
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make: Legrand, L&T and Schneider
40 Amps. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make: Legrand, L&T and Schneider
40 Amps. Cat-A.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- Make: Legrand, L&T and Schneider
Double door-12 way
Earthing with G.I. earth plate 600 mmx600 mmx 6 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using salt and charcoal for pipe earth electrode complete as required.
Supplying and laying 6 SWG G.I. wire at 0.50 mtr. below ground level for earth electrode conductor, including soldering etc. as required.
Providing, Installation, testing and commissioning of ceiling fan with socket size step type electronic fan regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required.
Ceiling Fan 1200 mm sweep
Makes:- ,Bajaj , Pansonic,Usha (At par with usha Technix Plus 3 Star)
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:-
Exhaust Fan, Light duty, (Domestic) 300 mm sweep
supplying and Fixing of surface mounting 2x2 size LED solution suitable for surface applicationwith the use for latest technology 36 Watt ( 3600) lumens) K-6000 and it shold be compatible with spectfcations i.e. Power factor > 0.9 , Harmonic dlstortion < 10% and efftcacy > 100 tumens per watt, CRL>80. sultable for lnput voltage AC 220-240v ,50/60 HZ complete with all accesseries,including connections,testing and commissioning etc.as required complete in all respects
Recess/Surface Mounting ( 36 Watt) (2x2)-
Makes:-Bajaj, Panasonic Philps , Jaquar {at par with Jaquar Cat No. LSVR01SO36SC }
Providing and installation of following type of Surface mounting slim Round type LED Downlight luminaire 1800 lumens CCT(K)- 5700 with spectfcations i.e. Power factor > 0.9 , Harmonic dlstortion < 10% and efftcacy > 100 tumens per watt, CRL>80. sultable for lnput voltage AC 220-240v ,50/60 HZ omplete with all accesseries,including connections,testing and commissioning etc.as required complete in all respects
20 Watt , square Surface LED- (1x1)
Makes:-Jaquar, Panasonic Philps , Bajaj,{at par with Jaquar Cat No. LSVR01150SO20XC }
Providing and fixing indoor decorative aluminium extruded LED Batten (including T-8 Tube Rod) and it should be compatible with specification i.e. Power Factor > 0.9, Harmonic Distortion <10% and efficacy > 100 Lumens per watt, CRI rating> 80 suitable for input voltage: AC 220-240 V, 50 Hz, complete with all accessories, connections, testing and commissioning etc. as required.
Batten for T8 Tube Light ( Including T-8 Tube Rod), Suitable For 1X18 Watt LED
Makes( Batten for T-8 Tube Rod) :- Panasonic, Philips, Jaquar, Bajaj( At par with Bajaj Cat. No. BLRB DB 118 )
Makes ( T-8 Tube Rod):- Panasonic, Philips, Jaquar, Bajaj( At par with Bajaj Cat. No. BLRB 18 W CWC )
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-
Armoured cable 16 sq. mm (twin core)
Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation sand cushioning, protective covering and refilling the trench etc. of the required size:-
Armoured cable 16 sq. mm (twin core)
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:-
50 mm. dia
Providing and fixing following rating double pole switch disconnector fuse unit cubical type, 415/500 volts, with 2 No. HBC/HRC fuses, in sheet steel enclosure including drilling holes on the board, connections, earthing the body etc. as required.
32 Amp. Category-A
Supplying and fixing of following way SEGREGATED, triple pole and neutral, sheet steel MCB distribution board, 415 volts, on surface / recess, with provision to mount 8 module incomer, 4 module sub-incomer in each phase and SP MCBs as outgoing, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-
4+2 way 8+6+12 Modules
Make- Havells,Hager , Gold Medal
supplying and Fixing Street Light LED 45 Watt suitatble for outside applicationwith the use for latest technology 45 Watt ( 4500) lumens) K-6000 and it shold be compatible with spectfcations i.e. Power factor > 0.9 , Harmonic dlstortion < 10% and efftcacy > 100 tumens per watt, CRL>80. sultable for lnput voltage AC 220-240v ,50/60 HZ omplete with all accesseries,including connections,testing and commissioning etc.as required complete in all respects
LED Street Light 45 Watt
Makes:-Bajaj, Panasonic Philps , Jaquar {at par with Jaquar Cat No. LSRTO1SO45XC }
Supplying and Fixing of surface mounting LED solution suitable for surface applicationwith the use for latest technology 10 Watt ( 1000 lumens) K- 5700 and it shold be compatible with spectfcations i.e. Power factor > 0.9 , Harmonic dlstortion < 10% and efftcacy > 100 tumens per watt, CRL>80. sultable for lnput voltage AC 220-240v ,50/60 HZ omplete with all accesseries,including connections,testing and commissioning etc.as required complete in all respects
10 Watt ,Bulk Head LED
Makes:-Havells, C&S, Panasonic{at par with Panasonic Cat No. LSRTO1SO45XC }
anil kumar govt. contractor
NITIN PROP A VIGHNA ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .