Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹33.3 L+₹44,094.65 (1.34%)Rejected-Finance 33 MAHAVEER NAGAR NANDRI ROAD PO SARAN NAGAR JODHPUR 342015 | JODHPUR | JODHPUR | RAJASTHAN | 342015 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹33.8 L+₹95,119.65 (2.90%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹33.9 L+₹1.1 L (3.34%)Rejected-Finance PAHARGANJ SECOND COLONY LAL SAGAR JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance Not lowest bidder |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
1 Jun 2022, 6:00 pmClosed
Garrison Engineer Banar
Garrison Engineer Banar, Jodhpur-342027
REPAIR AND REPLACEMENT OF HIGHBAY LED LIGHTS,FLAMEPROOF LIGHTS IN THE HANGAR,RUNWAY/TAXI WAY LIGHTS,RUNWAY CABLE,CCR UNITS AND OTHER CONNECTED WKS FOR TECH AREA AT RALAWAS UNDER GE BANAR
2022_MES_502445_2
8821/30/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Banar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer Banar
₹79,000
Yes
13 Jun 2022
30 Apr 2022
3 Jun 2022
30 Apr 2022
1 Jun 2022
18 May 2022
Amount
Disconnecting/taking down old existing unserviceable Panel any type all as directed.
Dismantling/taking down old existing unserviceable UG Cable diff size all as directed. Note : Earth work shall be measured and paid seprately.
Dismantling/taking down old existing unserviceable flood/street/highbay light any type all as directed.
Dismantling/taking down old existing unserviceable earthing set of any type all as directed.
Excavation in trenches not. exc. 1.5m wide and not exc. 1.5 deep and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, watering and well ramming in layers not exc 25cm in any type of soil complete all as specified and directed by Engr-in-Charge.
Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
Material and labour for sand cushioning for under ground cable with locally available sand for protection of cable including spreading and consolidations, complete all as specified and directed. Note: Punned thickness shall be measured, which shall be minimum 18 cm.
M&L for laying 40 to 50 mm thick quarry faced stone slab 25 to 30 cm wide and not exceeding 60 cm long laid dry abutting each other with gap between adjacent patties n.exc 10 mm for UG cable protection complete all as specified and dirtected
Supply, Installing,testing and commissioning of LT Panel factory made outdoor type (CPRI approved) as per latest IS mark with minimum thickness - Load bearing member/Doors - 2mm, Non-load bearing member/internal partitions - 1.5mm, Glandplate/Base channel-3MM and board floor mounted, dust and vermin proof, 3 phase 4 wire with rated operational voltage 415V, rated insulation voltage of 1000V and Impulse withstand of 8kV and minimum internal Arc with-stand of 65kA, 500mSec as per latest IS mark, weather proof, with separate hinge door for each compartment with Operating handle & locking arrangement with back door common openable(screwed/Lockable), grouted in PCC 1:2:4 Complete. Painting as per defined 7 Tank process with epoxy powder polymerized at high temperature and aluminium busbar (TPN) suitable for 150A with double compression aluminium cable glands with the following accessories with IP 54 rating :- (For Industral Socket Panel) (a) Incoming - MCCB 125 Amp 4 pole 415 V 25 kA rating (b) Outgoing - (i) Angle Type industral socket 63Amp Panel mounting (3P+N+E) - 02Nos (II) Angle TypeIndustral Socket 32Amp Panel mounting (3P+N+E) - 02 Nos . (III) Angle Type inustral Socket 16Amp panel mounting (3P+N+E) - 01 nos . (V) LED indicating lamps for main supply (R-Y-B)
Supply and Fix Energy saving and environmental friendly long life Versatile pressure die cast aluminium IP-65 surface /roof mounted highbay light fittings luminaire with high power,light weight LED of capacity 200 watt external surge protection complete all as specified as per directed by EIC Note:- The building has highrised so arragement of fixing light shall be made by contractor without any extra claim .
Supply and Fix Energy saving and environmental friendly long life Versatile pressure die cast aluminium IP-66 flood light fittings luminaire with high power,light weight LED of capacity 200 watt external surge protection complete all as per specified . .
M&L for factory made street/gate/flood light polycarbonate junction box,3 phase, 4 wire, 415 volts, weather proof pole mounted of suitable size as per site requirement with properly insulated aluminium buses-04 Nos of 10 Amps rated current cap with holes for connecting of cables, with hinged door and locking bolt, handle complete all as directed by Engr-in-charge
Material & Labour for wire mesh cover enclouser of dispersal light fittings over PCC foundatation with suitable locking arrangement all as directed by Engr-in-charge .
Material & Labour for PCC foundatation/Piller of suitable size & PVC pipe fixing for cable entry in PCC piller or another work with 1:3:6 type C-2 using 40mm graded aggregate etc complete all as specified and directed.
Cutting of road, hard standing,PCC 45cmX45 cmx30cm for laying of cable and making good surface with existing specification give the shape of cable trench as per site requirement as per directed by Engr-in-Charge
Material and labour for 80 mm dia galvanized iron tube light grade as in replacement for cable protection , road crossing, trenches, footpath etc, complete including clamps, nut bolt and washers as all specified and directed.
Material and labour for 40 mm dia galvanized iron tube light grade as in replacement for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, complete all as specified and directed including clamps, nut bolt and washers as all specified and directed.
Boring under road and foot path for inserting 40/80 mm bore GI tubing for drawing UG cable, complete all as per specified and directed.
Laying Only XLPE insulted, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable, heavy duty, with aluminium conductor 1100 volts grade, cross sectional area 70 sqmm,3.5 core complete all as per specified and directed.Note:- Cable will be issue under Sch 'B' free for fixing.
Laying Only XLPE insulted, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable, heavy duty, with aluminium conductor 1100 volts grade, cross sectional area 25 sqmm,4 core complete all as per specified and directed.Note:- Cable will be issue under Sch 'B' free for fixing.
Supply and Fix in replacement Industrial plugs and sockets panel mounted (3P+E) 125A 415 V complete as per specified and directed by Engr-in-Charge
Supply and Fix in replacement Industrial plugs and sockets panel mounted (3P+E) 63A 415V Complete as per specified and dirtected by Engr-in-Charge
Supply and fix in replacement Industrial plugs and sockets panel mounted (3P+E) 32A 415V Comlete as per specified and directed by Engr-in-Charge
Supply and fix in replacement Industrial plugs and sockets panel mounted (3P+E) 16A 415 V complete as per specified and directed by Engr-in-Charge
Supply and fix in replacement LT bus bar panel out door type of size 0.9 x0.6x0.3 mtr with 04 nos alluminium busbar with 32 TPN as incommer and MCB SPN 16 amps as out going 4 nos with complete acessories all as directed .
M & L for building earthing complete with galvanised steel earth plate electrode 60 x 60x 6mm burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level, connected to galavanised iron earth lead by means of bolt, nut, check nut and washer of galavanised iron strip 32x6mm as earthing lead as shown in Electrical Plate No 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/ loose soil, earth pit in PCC 1:3:6 type C1 using 20mm stone aggreate, funnel, 20mm dia GI medium grade water pipe, 15mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs, wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation and earth work pit cover including disposal of surplus soil to a distance not excessding 50m, complete testing on completion all complete as shown in electrical plate No 3 of SSR Part I 2009 all as directed by Engr-in-Charge
Supply, Installation, testing and commissioning in replacement of high intensity 200 watt bi-pin lamp for runway lights complete all as specified and directed by Engineer-in-charge.
Supply, Installation, testing and commissioning in replacement of high intensity 200 watt bi-pin lamp holder in repair for runway lights complete all as specified and directed by Engineer-in-charge.
Supply, Installation, Testing & Commissioning in replacement of Medium Intensity 45 watt bi-pin lamp for runway taxiway lights. complete all as specified and directed by Engineer-in-charge.
M & L in finding and rectifying the fault in Runway/Taxiway lights by duly locating fault and rectifing by checking the circuit in series / light to light including Excavation and Returning filling if required at site. complete all as specified and as directed by Engineer in charge. Note:- Lamps, Lamp Holder, connectors, transformers, cables etc required in rectifying the fault will be measured and paid seperately under relevent items of Schedule.
Supply and Fix in replacement Main Control Card including RMS to DC converter Card for 4/7.5KW CCRcomplete all as specified and directed by Engineer-in-charge
Supply and Fix in replacement Power supply and driver Card for 4/7.5 KW CCR complete all as specified and directed by Engineer-in-charge
Supply and Fix in replacement Insulation Monitor Card for 4/7.5 KW CCR complete all as specified and directed by Engineer-in-charge
Supply and Fix in replacement Over current Trip card Nos -02 for 4/7.5 KW CCR complete all as specified and directed by Engineer-in-charge
Supply anf Fix in replacement Relay card for 4/7.5KW CCR complete all as specified and directed by Engineer-in-charge
Supplyand Fix in replacement Plug for relay 24VDC suitable for 4/7.5KW CCR complete all as specified and directed by Engineer-in-charge
Supplyand Fix in replacement Plug for relay 48VDC 11 Pin suitable for 4/7.5KW CCR complete all as specified and directed by Engineer-in-charge
Supplyand Fix in replacement Plug for relay 240VDC suitable for 4/7.5KW CCR complete all as specified and directed by Engineer-in-charge
S & F in replacement of flexible matelic conduit from ceiling rose/Junction box to fitting to cover the exposed wire complete all as specified
Supply and Fix in replacement HRC fuse link 4 Amps suitable for 4/7.5KW CCR complete all as specified and directed by Engineer-in-charge
Supply and Fix in replacement HRC fuse link 32 Amps suitable for 4/7.5KW CCR complete all as specified and directed by Engineer-in-charge
Supply and Fix in replacement HRC fuse link 63 Amps suitable for 4/7.5KW CCR complete all as specified and directed by Engineer-in-charge
M & L for 5 KV grade plug and receptable of type - I class -B connector and suitable for field attachment with 5 KV grade PVC insulated PVC sheathed single core copper conductor cable as required and confirming to the specification as required.
M&L for medium intensity 15watt ,6/6.6 Amps,5KV,50Hz,0.95PF individual lamp series to series type isolating transformer encapsulated in polyester resin , finally moulded with neoprene type rubber compliant to FAA specification no. 150/5345-47C specification complete all as specified and directed by Engineer-in-charge.
Supply and Laying in replacement of 6 Sqmm 5 KV grade single core, stranded copper conductor PVC insulated & PVC sheathed, underground airport lighting cable generally.confirming to IS: 1554 Part-II 1981 with upto date amendment as required. complete all as specified and as directed by Engineer in charge.
Supply and fix in replacement transformer housing box made of FRP material suitble for receive a light base plate.
Material and labour in replacement of ALCMS Network Adaptor with SMPS card inclulding maintenance of ALCMS network adaptor complete all as specified and directed by Engineer-in-charge
Material and labour in replacement of ALCMS Network Adaptor Communication card inclulding maintenance of ALCMS network adaptor complete all as specified and directed by Engineer-in-charge
Material and labour in replacement Vault Processor I/P & O/P Module complete all as specified and directed by Engineer-in-charge
Material and labour in replacement of ALCMS Control panel wiring with 2.5sqmm single core size of wire as existing and with contractors complete all as specified and directed by Engineer-in-charge
Material and labour in replacement for replacing of ALCMS network Adaptor CPU EDS 510A card complete all as specified and directed by Engineer-in-charge
Material and labour for replacement of Splicing of Fiber Cable with connector complete all as specified and directed by Engineer-in-charge
Supply ,install and testing in replacement Thyristors 85RK 160 for 4/7.5 KW CCR complete all as specified and directed by Engineer-in-charge
Supply and fix in replacement flameproof ceiling fan regulator 230v 50Hz complete all as specified and directed by Engineer-in-charge
Supply and fix in replacement flameproof switch socket and plug(2P+E) 16Amp 250V complete all as specified and directed by Engineer-in-charge
Supply and fix flameproof switch socket and plug(3P+E) 16Amp 415V complete all as specified and directed by Engineer-in-charge
Supply and fix in replacement spare Plug for 16 Amps 250V (2P+E) complete all as specified and directed by Engineer-in-charge
Supply and fix in replacement spare Plug for 16 Amps 415V (3P+E)complete all as specified and directed by Engineer-in-charge
Supply and fix in replacement LED light fiiting 2x16 watt flame proof ,CMRI certified recommended for gas/vapor group of IIA & IIIB Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixture driver,holder,connector etc,complete with all three core flexibble copper conductor cable with suitable size complete all as specified and directed by Engineer-in-charge
Supply and fix in replacement Reflector for twin flameproof light fitting complete all as specified and directed by Engineer-in-charge
suply and fix in replacement flameproof rotary switch with cable terminal box in LM6 10 Amp single pole on-off complete all as specified and directed by Engineer-in-charge
suply and fix in replacement flameproof rotary switch with cable terminal box in LM6 16 Amp single pole on-off complete all as specified and directed by Engineer-in-charge
suply and fix in replacement flameproof Junction box 100 dia upto 4 way in LM6 complete all as specified and directed by Engineer-in-charge
Supply and fix in replacement Flameproof Distribution board SPN 8 way Double door with 200 amps rated bus bar complete all as directed by engineer in Charge
Supply and fix in replacement Flameproof Distribution board SPN 6 way single door with 200 amps rated bus bar complete all as directed by engineer in Charge
Taking down carefully aluminium/copper point wiring of any type/size for Light, fan, socket or power complete including making good the disturbed surfaces finishing of wall / floor etc, complete all as specified and directed.
Taking down existing sub main wiring of any type/size complete from wall and making good the disturbed surface.
Taking out serviceable MCBs single pole of any capacities and refixing all as directed.
M&L Point wiring with 1.5 Sq. mm PVC insulated and unsheathed single core FRLS copper cable 1100 volts grade with Multi-stranded copper conductor in and including In Stove enamelled steel Conduit (heavy grade) and accessories fixed on walls/floors/ceilings etc alongwith continuous earth wire 1.5 Sq mm PVC insulated and unsheathed single core FRLS cable 1100 volts grade with stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screw etc complete all as specified for the following:-
One light point controlled by one switch.
One fan/ exhaust fan point controlled by one switch.
One switch socket out let point 5 Amps on independent board
One switch socket out let point 5 Amps on same board
Material and labour for surface point wiring with two single core FRLS PVC insulated unsheathed copper stranded conductor of size 4 Sqmm and one run of same size/specification for conteneous earthing connected to common earth dolly complete drawing in and including suitable size of In stove enamelled Steel conduit with all fittings and accessories fixed properly on wall or ceiling including PVC terminal boxes for mounting switches socket for 3 pin 15 amp independent board all as specified and as directed by Engr-in-Charge.
M&L Point wiring with 1.5 Sq. mm PVC insulated and unsheathed single core FRLS copper cable 1100 volts grade with Multi-stranded copper conductor in and including PVC casing caping (heavy grade) and accessories fixed on walls/floors/ceilings etc alongwith continuous earth wire 1.5 Sq mm PVC insulated and unsheathed single core FRLS cable 1100 volts grade with stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screw etc complete all as specified for the following:-
One light point controlled by one switch.
One fan/ exhaust fan point controlled by one switch.
One bell/buzzar point controlled by one bell push independent
One switch socket out let point 5 Amps on independent board
One switch socket out let point 5 Amps on same board
Material and labour for surface point wiring with two single core FRLS PVC insulated unsheathed copper stranded conductor of size 4 Sqmm and one run of same size/specification for conteneous earthing connected to common earth dolly complete drawing in and including suitable size of PVC casing & capingwith all fittings and accessories fixed properly on wall or ceiling including PVC terminal boxes for mounting switches socket for 3 pin 15 amp independent board all as specified and as directed by Engr-in-Charge.
Supply and fixing switch piano flush type 5 Amp single pole, one way complete all as specified and directed by Engr-in-Charge.
Supply and fixing for ceiling rose surface bakelite 65 x 50 mm three terminal complete all as specified and directed by Engr-in-Charge.
Supply and fixing socket outlet 5 pin 5 Amps, flush type complete all as specified and directed by Engr-in-Charge.
Supply and fixing Socket outlet 5 in 1 3 pin 6 and 16 amp flush type complete all as specified and directed by Engr-in-Charge.
Supply and fixing Socket outlet 2 in 1 5 pin 5 and 5 amp flush type complete all as specified and directed by Engr-in-Charge.
Supply and fixing bell/buzzer Ding dong AC 230 Volts single pole complete all as specified and directed by Engr-in-Charge.
Supply and fixing stepped type electronic fan regulator, resistance type complete all as specified and directed by Engr-in-Charge.
Supply and fixing Modular Switch Socket combination 16A 6 Pin 3 module with plate as specified as per directed
Supply and fixing Modular Switch Socket outlet multipurpose 3 pin 16 Amp and one pin 6 Amp controlled by one switch as specified as per directed
Supply and fixing modular sockets 6Amp 2/3 pin 2 module all as specified.
Supply and fixing modular sockets 6/16Amp 2/3 pin 2 module all as specified.
Supply and fixing modular Fan step type regulator 2 module all as specified.
Supply and fixing modular white coverplate with frame 2 module all as specified.
Supply and fixing modular white coverplate with frame 6module all as specified.
Supply and fixing modular white coverplate with frame 8 module all as specified.
Supply and fixing modular Switch 1 way 6A 1 module all as specified.
Supply and fixing modular Switch 1 way 16A 1 module all as specified.
Material and labour for sub main wiring with two single core FR PVC insulated unsheathed copper stranded conductor of size 2.5 Sqmm and one run of size 2.5 Sqmm for continious earthing connected to common earth dolly complete drawing in and including suitable size of In Steel conduit with all fittings and accessories fixed with clamp properly on wall or ceiling as per specified as directed by Engr-in-charge
Material and labour for sub main wiring with two single core FR PVC insulated unsheathed copper stranded conductor of size 6 Sqmm and one run of size 6 Sqmm for continious earthing connected to common earth dolly complete drawing in and including suitable size of In Steel conduit with all fittings and accessories fixed with clamp properly on wall or ceiling as per specified as directed by Engr-in-charge
Material and labour for sub main wiring with two single core FR PVC insulated unsheathed copper stranded conductor of size 10 Sqmm and one run of size 10 Sqmm for continious earthing connected to common earth dolly complete drawing in and including suitable size of In steel conduit with all fittings and accessories fixed with clamp properly on wall or ceiling as per specified as directed by Engr-in-charge
Supply and fixing in repair powder coated sheet metal enclosures MCB DB, double door, single pole and neutral 8 way 240 Volt fitted with bus bar, DIN channel, neutral link and incoming contact complete all as specified.
S&F in replacement powder coated sheet metal enclosures VTPN DB, double door, tripple pole and neutral, 4 way 415 volts fitted with insulated vertical phase bus bar/neutral bar with shround earth bar cement spill proctector interconnecting wire set cable tiesblanking plates and circuit indentificationlables etc all as per IS-8623-1 IK-09
Supply and fixing in replacement MCB SPN 6-32 Amps 240 volts complete all as specified.
Supply and fixing in replacement MCCB TPN 125 Amps 415 volts. 18kA Adjustableoverload setting l &fixed magnetic setting complete all as specified
Supply and fixing in replacement MCB SP 6 Amps to 32 Amps 230 Volt complete all as specified.
Fixing only surface mounting batten tube light fitting, integrated polycarbonate LED channel with white acrylic cover complete suitable for and including lamp LED 1x20 Watt,(4 feet) fixed properly on wall surface and connecting complete from ceilling rose to fitting by three core copper conductor cable of overall sheathed size 2.5 Sqmm which shall be passed through PVC flexible conduit all as directed. Note:Tube light fitting will be issue under Sch 'B' free for fixing.
S&F in replacement Metal Clad Plug and socket with box 20 Amp with MCB complete fixed properly on wall surface with the provisioning of suitable sizes of bolts, nuts, washer and to connect by using cable PVC insulated copper stranded conductor of size 4 Sqmm as per specification as per dirteced
S&F in replacement AMF panel relay 3 Phase main for 63KVA operating voltage 8-30 VDCwith reverse polarity protection with LED display with indication auto,manual mode operation,last 60 event records as faults maximum display error+/-1% of full reading operating temp 0-70 degree also show low fuel percentage level as per specified as directed .
S&F in replacement MCCB 4 Pole 125 Amp 16KA all as specified.
S&F in replacement MCCB 4 Pole 100 Amp 16KA all as specified.
Supply,fixing and testing in replacement of LED 45W driver with surge protection complete connection to LED Flood/street/highbay light fitting with suitable wire as specified as per directed by EIC
Supply,fixing and testing in replacement of LED 75W driver with surge protection complete connection to LED Flood/street/highbay light fitting with suitable wire as specified as per directed by EIC
Supply,fixing and testing in replacement of LED 100W driver with surge protection complete connection to LED Flood/street/highbay light fitting with suitable wire as specified as per directed by EIC
Supply,fixing and testing in replacement of LED 150W driver with surge protection complete connection to LED Flood/street/highbay light fitting with suitable wire as specified as per directed by EIC
Supply and fixing in replacement of LED PCB board for 45/60KW light fitting board thickness 1.6mm for Flood/street/highbay light fittingcomplete with connection as specified as per dirtected
Supply and fixing in replacement of LED PCB board for 90/100KW light fitting board thickness 1.6mm for Flood/street/highbay light fitting complete with connection as specified as per dirtected
Supply and fixing in replacement of LED PCB board for 150 KW light fitting board thickness 1.6mm for Flood/street/highbay light fitting complete with connection as specified as per dirtected
Preventive maintance of Online UPS 3 Phase 415V 50Hz of capacity upto 10KVA by high skilled trademan including cleaning of UPS panel with blower & tighting of all power and control terminations points and repair / fix of unserviceable spare parts such as PCB card,IGBT, voltmeter 500v : 96mm-02Nos, 300V:72mm-03Nos,Three phase control panel -01No, Capacitor , filter coil control transformer (CTs) and battery bank reinstalling at its original position after repair complete servicing, testing of UPS to be done to check the serviceability condition of same all as directed by Engr-in-Charge.Note:- Spare parts will be paid seperatly under relevant items of Sch
S&F in replacement IGBT modules complete set of 150Amp 600V suitbale for 10KVA Online three phase UPS complete all as specified.
S&F SMPS in replacement for DC power for providing different types of Input power supply of various driver cards of 5/10KVA Online UPS complete all as specified.
S&F in replacement Galvanised iron wire 4mm dia with clips connecting upto test point or DB as specified as per directed by EIC
S&F in replacement MS conduit 20mm bore medium grade pipe flame proof light or passing through PEB shed wall etc connection with suitable clips,nut,bolt all complete as per directed by EIC
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .