| 1 | L1₹7.0 LAccepted-AOC 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹7.5 L+₹41,535 (5.89%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L2 | Rejected-Finance Not being lowest | |
| 3 | Rejected-Technical 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | - | Rejected-Technical Adverse remarks in WLR for sister concern firms |
Tender Value
Refer Docs
EMD Value
₹17,280
Closing Date
15 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Ambala
Headquarter Commander Works Engineer Ambala Mansfield Road Ambala Cantt
CA NO CWE/AMB/UTILITY-02 OF 2024-25 ADDITIONS AND ALTERATION OF LT ELECT NETWORK SYSTEM WITH ALLIED WORKS AT KV NO. 01 RESIDENTIAL COMPLEX UNDER GE (UTILITY) AMBALA CANTT
2024_MES_652134_2
CWE/AMB/UTILITY-02 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Ambala Cantt
All as per tender documents
9 documents required · 9 mandatory
₹500
GE UTILITY AMBALA CANTT
₹17,280
Yes
21 Sept 2024
24 Jun 2024
17 Jul 2024
24 Jun 2024
15 Jul 2024
2 Jul 2024
24 Jun 2024 - 27 Jun 2024
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, shafts, man holes,for under ground cable / erection of poles,locating fault of LT cable and stay assembly etc not exceeding 10 Square metre on plan and getting out in soft/loose soil including dressing/trimming of sides and leveling, grading and ramming of bottom of excavation complete all as specified and as directed.
All as per item No. 1 above but excavation depth exceeding 1.5 metre and not exceeding 3.0 metre.
Returning, filling in, in soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick of any description, complete, all as specified and as directed.
Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Material and labour for Sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth after laying and stretching of cable ) complete all as specified and as directed.Note:- Punned thickness 18cm shall be measured for payment purposes.
Supply and laying sub class 'B' bricks old sizes over the HT/LT cable laid flat with width equal to length of brick, laid perpendicular to the cable for protection complete all as specified and as directed.
Material and labour for PCC 1:4:8 type D-2 (using 40 mm graded mechanically crushed stone aggregate), as in mass filling in pole pit and foundationetc., complete all as specified and as directed.
Material and labour for PCC 1:3:6 type C-1 (using 20 mm graded mechanically crushed stone aggregate), as in coping of pole and strut, stay around pole etc., complete all as specified and as directed.
Material and labour for PCC 1:2:4 type B-1 (using 20.00 mm graded mechanically crushed stone aggregates) as in coping of poles including necessary form work and finishing the exposed surface even and smooth without using extra cement, complete all as specified and as directed.
Supply and errection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 metres long) conforming to IS-1678 and including marking alternate 05 Nos white and black strip 30cm height with two coats of synthetic enamel paint including preparation of surfaces, upto 1.5 metre above the coping of pole, starting with black strip with and including of galvanized/ mild steel circular lantern carriage arangement suitable for 04 luminaries symmetrically on steel tubular poles complete all as specified and directed. Note: Excavation and earth wok and PCC for foundation, channel, clamps nuts, bolts to be measured and paid separately.
Disconnecting & taking out defective underground cable from trenches, pole, pipe, floor, wall etc and locate the fault, rectify the defect and relaying the XLPE cable underground PVC insulated and overall sheathed aluminum conductor heavy duty 1100 volts including connecting and testing for any size complete all as specified and directed. Note: Excavation, earth work, cable cover protection, sand cushioning, bricks and joint etc shall be measured & paid for separately.
Supplying and laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (Heavy duty) with aluminium conductor, 1100 Volts grade, cross sectional area 70 Sqmm 3.5 core, suitable for 1.1 KV earthed system, in trenches, floors, ducts passing through pipe for road crossing etc, including connecting and testing,complete all as specified and directed. Note : Excavation, earth work, cable cover protection, sand cushioning and GI pipe etc shall be measured & paid for separately.
All as per item No. 12.00 above but size of cable 25 Sqmm 4 core.
All as per item No. 12.00 above but size of cable 10 Sqmm 4 core.
Supply and fixing in replacement of GI tubing, 50mm bore, light grade, for cable protection along/on poles/culvert/drainage or under road crossing, complete, all as specified and as directed.
Material and labour for boring of holes under road, pavement, hard standing of any material and description, by trench less technology using ultra sound technique or manual boring including supply and laying of HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure complete, all as specified and as directed. Note:- Any damage of other property like sewage pipes, other cables , water pipes etc will be repaired/replaced under this item without extra cost , department will not responsible of any damage.
Material and labour for outdoor end termination heat shrinkable joint 1100 volt for XLPE cable of size 10 to 50 Sqmm 3.5/4 core with jointing material and accessories fixed as per manufacturer instruction complete all as specified and directed.
Material and labour for outdoor end termination heat shrinkable joint 1100 volt for XLPE cable of size 70 to 150 Sqmm 3.5/4 core with jointing material and accessories fixed as per manufacturer instruction complete all as specified and directed.
Supply, installing, testing & commissioning of factory fabricated outdoor type feeder pillar board of size 1000mmX900mmX500mm, outer shell made out of 3.15 mm thick CRCA sheet and inner shell made out of 2 mm thick CRCA sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 80 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door system and cable alley (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able with arrangement of pad locking on door 01 no of pad lock of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coated painting after 7-tank pre treatment control & power wiring with suitable size of copper conductor along with suitable gasket to make it dust/vermin proof and general construction confirming to IS:61439/2011 Part-1 and part -2 type test certificate with not less than IP-65 and breaking capacity 56 KA comprising of the following - (a) MCCB 160 Amps TPN, 25 KA-01 No (incoming) (b) MCCB 63 Amp, 10 ΚΑ ΤΡΝ 415 volts AC, (Outgoing) - 06 Nos (c) Copper busbar of capacity 250 Amps with colour coated heat shrinkable sleeve and suitable hole for out going connection - Set of four (d) Multi function meter with KWH, voltage, Amp, frequency meter (e) Indicator lamp for R,Y & B for each incoming and outgoing feeder including misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves, glands etc complete are included in quoted rates.
Supply and fixing of sheet metal enclosure Vertical triple pole & neutral (VTPN) with MCCB TPN 125 Amp for 415 volts 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed surface with PCC 1:3:6 complete all as specified and directed.
Supply, fixing and passing through PVC conduit pipe of 1100 volts grade heavy duty, PVC insulated round 3 core 1.5 sqmm copper cable with PVC conduit pipe fixed with clamp & nuts bolts including electrical connection suitable size of lugs, complete all as specified and as directed.
Supply & fixing in replacement of Sunbeam Senso LED Sensor street light fitting 60 watts made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 consisting of suitable number of LEDs with sealed toughened glass cover, 5700K, LED efficiency >110 lm/Watt and system efficiency 110 lm/W , 230 Volts AC, 50 Hz, CRI>70% operating voltage range 140 V-270 V, Power factor> 0.95,mains current 0.210A, working temperature range -10ºC to 50ºC,built in surge protection of more than 10 KV, autonomous sensor based dusk to dawn SL, IR sensor to mitigate the effect of surrounding, artificial lightbetter optics for uniform distrubution with multiple LEDs not less than 2 watt each and having optical grade polycarbonate lens with all accessories , suitable for side entry, pole mounting with bracket arm OD 40 mm, recommended mounting height with suitable inground reinforcement is 8 mtrs, Confirm the safety test as per IS 16107 part-2 from auth labs : LM79 & LM 80, incl proper fixing and testing of street lights on 9/11 mtr long steel tubular pole and provide facility of power supply shall be provide as suitable for maint work of light fittings incl make proper connection of new and existing light fittings complete with cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engineer-in-charge. Make :- Havells cat part no ENDURASUNBEAMSL60WLED757SASYTOPCSENSO or equivalent of makes as specified in tender documents. Note :-PVC heavy duty conduit pipe along with 3/1 run of 1.5/2.5 sqmm PVC insulated unsheathed/sheathed copper multistranded conductor from MCB box to street shall be measured and paid for separately.
Supply & fixing in replacement of bracket made out of GI tubing bore 40mm , light grade, single piece bended at proper angle 1.5 mtr long including painting with aluminium paint over one coat of primer to the bracket of street light fitting all as specified and as directed.
Supply & fixing in replacement of MS clamp suitable for holding street light bracket on steel/PCC pole made out of 40 mm x6 mm thick flat iron with M.S nuts bolts 50 mm long 10 mm dia -3 Nos with flat washer 3mm thick -02 No for each including painting with aluminium paint over one coat of red oxide primer to the M.S clamps all as specified and as directed
Supply and fixing in replacement of Kiosk box made out of fibre material complete to accomodate with TPN ,aluminium bus and suitable for one number MCB (SP) including one No MCB (SP) 10 Amps 240 volts with glands for incoming & out going cable including fixing of flat iron clamps of size 20x4mm on PCC/Steel tubular pole complete all as specified and as directed.
Supply, fixing and testing of auto day/night on and off photocell, LDR sensor switch 10 amps for lighting on/off, water proof 220 volt 50 Hz, AC supply, complete with all accessories internally pre-wired including connection with 1.5 Sqmm copper conductor from main supply to sensor, sensor to fittings complete all as specified and directed. Make;- Model No. Quick Sense QS-301 or equivalent of makes as specified in tender documents.
Supply and fixing of MCB SP 6-32 Amps, 240 volt,10 KA 'C' curve including removing old Unserviceable MCB complete all as specified and directed.
Supply and fixing of MCB TPN 63-100 Amps, 450 volt,10 KA 'C' curve including removing old Unserviceable MCB complete all as specified and directed.
Material and labour for sub main wiring with two single core, 6 sqmm, FRLS-H, 1100 volts grade, ISI marked, with multistranded, PVC insulated unsheathed copper conductor cable, drawn in and including rigid non metallic PVC conduit, medium grade, not less than 25 mm dia, ISI marked for housing cables, concealed in wall or ceiling including cutting chasing and making good, with accessories with and including one additional 6 sqmm, PVC insulated, stranded copper conductor, FRLS-H, green colour for earth continuity conductor connected to common earth dolly and making good the disturbed surface complete all as specified and as directed.Note- Three runs of 6.0 sqmm cable and one run of concealed conduct shall be measured as one unit.
Material and labour for earthing complete galvanised earth plate electrode 600mm x 600mmx 6.00mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to 25x4 mm GI strip earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 40mm dia (light grade) and connected to main switch or main control board all as shown in electrical plate No.3 of SSR Part-I & including necessary excavation and earth work. The rate also include charcoal & salt in alternate layers, 20mm dia GI pipe (light grade) for watering and 40mm GI protection pipe, funnel, wire mesh, cast iron cover and frame etc, including testing on completion, including taking down of old earthing, complete all as specified and directed Notes : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire wesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of earth pit covers to be conspicuously marked of plate with stand grouted in PCC. (iii) On testing after completion if the desired earth resistance is more than 2 ohm the earthing will be redone at no extra cost.
Supply and fixing of cable gland as per cable size in the LT panels complete all as specified and directed.
Note:- Amount of credit of Rs. 7540.00 for retrieved materials is mentioned in Schedule of Credit Page No. 17 of tender documents in pdf form which will be deducted offline while acceptance of tender.
R D Bansal (BID ID -3054123)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .