Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹95.8 LAccepted-AOC 160 PREM NAGAR BAREILLY | L1 | Accepted-AOC Accepted | |
| 2 | L2₹99.7 L+₹90,763.75 (0.92%)Rejected-Finance 232 1 D SHIVLOK KANKARKHERA DISTT MEERUT UP PIN 250001 | MEERUT | MEERUT | UP | 250001 | L2 | Rejected-Finance Being higher Bidder | |
| 3 | L3₹1.1 Cr+₹9.6 L (9.73%)Rejected-Finance FLAT NO 330 PKT 1 SECTOR 1 DWARKA NEW DELHI 110 075 | NEW DELHI | NEW DELHI | DELHI | 110075 | L3 | Rejected-Finance Being higher Bidder | |
| 4 | L4₹1.1 Cr+₹11.2 L (11.3%)Rejected-Finance A 04 ADGNJ CHANDAN NAGAR OPP IOCL PETROL PUMP RAMPUR ROAD BAREILLY U P 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | L4 | Rejected-Finance Being higher Bidder | |
| 5 | L5₹1.2 Cr+₹23.6 L (23.9%)Rejected-Finance 145H 2G AQAMA MODEL APARTMENT LUKERGANJ PRAYAGRAJ UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211001 | L5 | Rejected-Finance Being higher Bidder |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
25 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Office BAREILLY
HQ, CWE, MES, Station Road, Bareilly
CA NO.CWE BLY/GE (W) / 36 OF 2023- 2024 SPECIAL REPAIRS TO BLDG NO P-9 (SINGLE LIVING JCOs LIVING ACCN), T-133A (PILLORA COY), T-38, T-39, T-41 AT MANGO COY AT JRC UNDER GE (WEST) BAREILLY
2023_MES_617052_1
8100/B/772/E8
Open Tender
Civil Works
Item Rate
270 days
GE WEST BAREILLY
As Per NIT
6 documents required · 6 mandatory
₹1,000
GE West Bareilly
₹2.2 L
Yes
27 Dec 2023
4 Sept 2023
27 Oct 2023
4 Sept 2023
25 Oct 2023
26 Sept 2023
Amount
M & L for non-skid ceremic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match of tiles over and including screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6 including dismantling of tiles & including cement mortar bedding (but not backing) & removing the rubbish off the premises complete all as specified directed
All as per serial item No 1 as above but as in vertical surfaces of tiles and rendering 10 mm thick in cement mortar 1:4, as in backing layer complete all as specified.
M & L for non- skid ceremic coloured tiles 7 to 8 mm thick (Square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6 including dismantling of tiles & including cement mortar bedding (but not backing) & removing the rubbish off the premises complete all as specified and directed.
M & L for 18-20 mm thick machine cut pre polished kota stone slab flooring laid and jointed with grey cement slurry fixed with pigment to match to shade of the slab including rubbing and mirror polishing over and including 20 mm thick bedding layer of cement mortar 1:6 including dismantling floor, hearth or wall kota stone slab/ rougning existing surface including cement mortar bedding (but not backing) & removing the rubbish off the premises complete all as specified and directed.
All as per serial item 04 as above but as in vertical surfaces including dismantling of tiles and rendering 10 mm thick in cement mortar 1:4, as in backing layer complete all as specified.
M&L for Glazed coloured ceramic tiles wall 600x300x7-8mm thick on vertical faces of walls including 10mm thick rendeing in CM 1:4 set jointed in neat cement slurry and pointed in coloured cement to match including taking down old dado/skirting complete all as specified.
M&L for Providing & injecting chemical for post construction ATT along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc in a portion with cement mortar 1:2 to match the existing apron complete all as specified and directed.
M & L for Post Construction Anti TermiteTreatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed.
Taking down chowkats with shutters (without taking off shutters from the frames) area not exc 1.5 Sqm each including making good disturbed portions to match the existing surface complete all as specified and directed.
Taking down chowkats with shutters (without taking off shutters from the frames) area exc 1.5 Sqm each and not exc. 4.00 Sqm including making good disturbed portions to match the existing surface complete all as specified and directed.
S & F Solid Prelam PVC Door Frame of size 50mm x 47mm made out of 5mm thick single side prelam PVC sheet used instead of Plain colour PVC sheet reinforced with MS tube, suppling & fixing in opening as per specification & drawing complete all as specifed and directed.
S&F 30 mm thick factory made one side Prelam PVC sheet other side decorative (door shutter) used instead of Plain colour PVC sheet. Stile and rails feathered at edges and on other side 10mm 90 degree bent edge consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C' channel heaving a Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site complete all as per specification & drawing.
S&F for 125x60mmx2mm thick (PBI Sheet) pressed steel, frames for door with one or more rebates including filing and inner surface of the frame shall be treated with a coat of bituminous paint & compaction with PCC 1:3:6 Type C1, necessary fixing lugs, SS hinges, lock strike plate, 02 x MS bar/flat at bottom of the frame etc, complete including wooden texture finished paint on the frame surface all as specified and directed.
S&F for 105x60mmx2mm thick(PBI sheet) pressed steel, frames for door with one or more rebates including filing and inner surface of the frame shall be treated with a coat of bituminous paint & compaction with PCC 1:3:6 Type C1 necessary fixing lugs, SS hinges,lock strike plate, 02 x MS bar/flat at bottom of the frameetc, including wooden texture finished paint on the frame surfacecomplete all as spd and directed.
S&F for 35 mm thick flush shutter, solid core construction with block board core and ply wood face panels, commercial type on both side, complete all as specsified & directed.
M & L for 35mm thick plain framed glazed and skeleton shutter(factory made) open rebated & prepared to receive glass, gauge etc, with sash bar edges of framing plain chamfered or rounded fitted with cut and mitered beads for securing glass including campsule mesh tightly fixed with the glazed and skelton door shutter etc, of 2nd class hard wood, members of shutters as specified in SSR Part - I Section 8 clause 8.24 (a) fitted to chowkats all as specified and directed. Note:- Campsule Mess will be measured and paid separately.
M & L for repair to shutters, resecuring, easing and adjusting without taking down the shutter of any description of size exceeding 1 sqm but not exceeding 2 sqm each and also refixing builders hardware as required including renewal of unserviceable screws, etc. complete all as specifed and directed.
S & F in repair factory made PVC cupboard frame of size 75mmx40mm with a wall thickness of 5 mm made out of extruded 5 mm thick plain/prelam PVC sheet of density 600kg/Cum, having bottom width of 50 mm and thickness of 10 mm, all four frame lengths reinforced with 15 mmx15mm MS square tube of 19 mm gauge thisknedd throughout the frame and mitre cut at two corner adjoined with 2 Nos of 15mm long brackets of 10mmx10mm MS square tubes. The door frame shall be provided to wall using 8/100 long MS screw to be providedfor each vertical members and minimum of 2 Nos of screw to be provided horizontal membes etc. complete all as manufacturer's drawing, as specified and directed.
S & F in repair factory made PVC cupboard flush shutter /shelve of 30 mm thick consisting of frame made out M S tube of 19 gauge thickness and size 19mmx19mm for stiles and rails. The inside panel shall consist of 20 mm thick multichamber hollow PVC section of 1mm wall thickness, bonded using solvent cement/suitable adhesive with 5 mm thick plain/prelam PVC sheet, on both side of inside panels including all four edge of the panels to be sealed with lipping of 10 mm thick and 20 mm wide PVC sheet baton (made by sticking 2 Nos PVC foam sheet of 5 mm thickness using PVC solvent cement adhesive) and shelves will be rest on PVC fillet 18 mm thick or on angle 25x25x3mm fixed with ecrews length equal to width of the shelve complete all as manufacturer's drawing, as specified and directed.
S&F for 100mm long Stainless steel butt hinges medium weight. complete all as specified and directed.
S&F for 150mm long aluminum anodised, barrel tower bolts of extruded section and fixed.
S&F for 200mm long aluminum anodised, barrel tower bolts of extruded section and fixed.
S&F for 150mm long aluminum handles, cast type complete all as specified and directed.
S&F for 150mm long Extruded aluminium alloy handles, fabricated type, anodised
S&F 300 mm long Aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixedmild steel complete all as specified and directed.
S&F galvanised Stainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanesed wire stapels complete all as specifed and directed.
M&L Preparation of old wooden surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L painting to wood and wood based surfaces of any description exc 10cm with or girth with two coats of synthetic enamel paint over a coat of pink primer including preparation of newly or previously untreated surface complete all as specified and directed.
M & L preparation of old steel surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for painting to steel surface exc 10 cm width or girth with two coats of synethic enamel paint over a coat of red oxide primer including preparation of newly or previously untreated surface complete all as specified and directed.
M & L for Plain Cement Concrete 1:3:6 type C-1(using 20 mm graded aggregate) as in bed blocks for hold fast/concrete filling in chowkhats and similar work etc complete all as specified and directed.
M&L 15mm thick cement plaster on brick surfaces or concrete surfaces (on external surface) in cm (1:4) using WPC @ 200 ml per 50 kg of cement , finishing the surface even and smooth without using extra cement and necessary scaffolding including taking down existing plaster complete all as specified and directed,(Note :- cost of WPC shall be included in the unit rate)
M&L 15mm thick cement plaster on brick surfaces or concrete surfaces (on external surface) in cm (1:4) using WPC @ 200 ml per 50 kg of cement newly surface even and smooth without using extra cement and necessary scaffolding complete all as specified and directed (Note :- cost of WPC shall included in the unit rate)
M&L 12mm thick cement plaster on brick surfaces or concrete surfaces (on internal surface) in cm (1:6) including taking down plaster finishing the surface even and smooth without using extra cement and necessary scaffolding complete all as specified and directed
M&L 12mm thick cement plaster on brick surfaces or concrete surfaces (on internal surface) in cm (1:6) newly surface even and smooth without using extra cement and necessary scaffolding complete all as specified and directed
M & L for rendering 5mm thick on ceiling or concrete surfaces in cement mortar (1:3) finished including taking down plaster the surface even and smooth without using extra cement and necessary scaffolding complete all as specified and directed
M & L for rendering 5mm thick on ceiling or concrete surfaces in cement mortar (1:3) newly surface even and smooth without using extra cement and necessary scaffolding complete all as specified and directed
M&L Two coats of oil bound distemper over a coat of primer on ceiling surfaces including preparation of newly plastered untreated surfaces and necessary scaffolding complete all as specified and directed
M&L for applying 1 mm thick layer of Birla wall care putty on external and internal wall surfaces incl rubbing down the surfaces with sand paper after getting dried all as directed to obtain a smooth & even surface complete all as specified and directed
M&L Preparation of old decorated surfaces and applying two coats of oil bound distemper on ceiling surfaces and rubbing down with sand paper to have even and smooth surfaces complete all as specified and directed
M & L for complete removal of existing treatment on wall by scrapping with mechanical sander (having mechanical vaccum machanisum) with sanding pad of appropriate grit to make surface clean, free from dust, loose paint etc by skilled labour and applying two coats of oil bound distemper on wall surface with airless electric sprayers over a coat of primer applied using electric spayers complete all as specified and directed.
M & L applying two coats of oil bound distemper on new plastered wall surfaces with airless electric spayer over a coat of primer appiled using airless electric sparyer complete all as specified and directed.
M & L applying One coat of cement based paint on old decorated or undecorated wall, roof surface including preparation of surfaces by washing rubbing down and stoping of distempered and painted surfaces complete all as specified.
M&L Two coats of cement base paint on new plastered wall surfaces over a coat of cement base primer of any description including preparation of surfaces, complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, aches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles all as specified and directed
M&L Brick work with fly ash bricks (old size) as per IS 12894 -2002 straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and directed.
M&L brick work with fly ash bricks (old size) as per IS 12894 -2002 straight or curved on plan to any radius in half brick thick walls built in CM (1:4) all as spd and directed
M & L for cutting chases of hanging chajjas, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of sunshades, shelves, lintels, Chajja ( up to IIIrd floor) etc making good, cutting out exc 10cm and not exc 40cm girth in RCC chajjas in brick walls complete all as specified and as directed.
Demolition of reinforced cement concrete, (other than ground floors), shelves, chajjas, slabs and stair case similar work carefully and matching to adjoining disturbed surfaces complete all as specified directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified directed.
M & L form work to edges of concrete rough finished surface flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide complete all as specified and directed.
Form work to soffits of suspended slabs flat surface of concrete finished rough surfaces of concrete not exceeding 200mm thick, complete all as specified and directed.
M & L formwork to sides and soffits of lintels,lintel bend, beams etc finished rough surfaces of concrete complete all as specified directed.
M & L formwork to sides of pillars, posts, struts, piers, columns and stanchions square, rectangular finishes rough surfaces of concrete.etc finished rough surfaces of concrete complete all as specified and directed.
M & L formwork to chullah hoods, chajjas, trough and similar items including edges finished rough surfaces of concrete complete all as specified and directed.
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F TMT bars 5mm and over upto and including 10mm dia in stirrups, spacers and binders bent to shape required,including binding with mild steel wire (annealed) not less than .9mm dia complete all as specified and directed.
M&L RCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in slab, shelves and stair case etc.complete all as specified and directed.
M&L RCC type B 1, 1:2:4 (20mm graded stone aggregate) as in beams, cantilevers, lintels, over 1.5 m span complete all as specified and directed.
M&L RCC type B 1, 1:2:4 (20mm graded agg) as in columns, pillars, piers, posts and struts complete all as specified and directed.
M&L RCC 1:2:4 type B1 using 20 mm graded aggregate as in chajjas and likecomplete all as specified and directed.
Dismantling of concrete by chiseling from RCC members like column , beam, parapet facia, chajja, ceiling,etc exposing the reinforcement without disturbing the reinforcement free from rust by sand blasting/using chemical, apply a coat of rustolin to remove rust and acralic polymer on old rusted reinforcement proving at places addl reinforcement welding with existing reinforcement as directed wherever required binding RCC 50 mmx 50 mm (10 mm gauge welded mesh ) & tack , securing with clips / linding wire, welding & provision guniting pressure 2.2 to 2.5 kg /sqm with admixer 1 cement 3.5 of sand of thickness 25 to 40 mm including stripping floating with wooden strippers for proper dimension control neccssary form work & scaffolding up to three storey and including height of head room complete surface of guniting to be finished fair with 10 mm thick plaster in cement mortar 1:4 with water proofing compound @ 200 ml every 50 kg of cement and applying two coat of Dr fixit /pidilite new coat ezee at interval of 8 hours cure for the surfaces complete all as specified and directed.
Demolition of cement concrete(un-reinforced), in ground floorand paving ( n.exc. 15 cm thickness below or above ground level) complete all as specified and directed.
M & L for 75 mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in paving, plinth protection finished even the surface fair and even including forming 10 mm wide joints at not exceeding 3 m distance between adjoining slabs shall not exceed 10 mm in thickness and shall be filled with bitumen mastic i.e. bitumen and sand in proportion 1:2 complete all as specified or as directed.
Providing water proofing treatment to RCC sunken slab as specified and directed as under:- (a) Cleaning the existing RCC sunken slab and vertical wall/RCC beam and hacking the surface. (b) 15mm thick plastering over the floor & vertical surface in CM 1:4, mixed with liquid water proofing compound @ 200ml per 50 kg of cement trowelled to even and smooth finish without using extra cement .(Water proofing compound shall be measured and paid separately). (c ) filling the sunken portion with water for 72 hrs and carring out the ponding test.(Any leakage /seapage noticed shall be repaired). (d) Applying two coats of elastomaric acrylic water proof coating per sqm in each coat with roller application.(Note: Each coat of elastomaric acrylic compound requires 6-8hrs to dry up itself second coat shall be applied on getting the first coat completely dried up.) ( Note- Liquid WPC shall be measured and paid separately under respective items)
Supply only liquid waterproofing compound all as specified.
M&L for cement concrete 1:5:10, type E2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
M&L for PCC 1:2:4, Type B0 ( using 12.5 mm graded stone aggregate) as in levelling course, haunching, coping and similar works of over RCC roof surface including rounded or chamferred on edges etc complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of concrete or brick surfaces in CM 1:4 mix with water proofing compound as per manufacturer's instruction but not less than @ 3% by weight of cement complete all as specified and directed.(NOTE:- WPC shall be measured and paid separatly)
Dismantling of roof terracing cement / brick concrete (un-reinforced) and existing water proofing treatment of any thickness in any position and of any portion from top of roof of building, cleaning surface of roof with wire brush / mechanical brush and with water thoroughly to remove all dust / dirt and loose particles to expose base concrete roof slab and removal of rubbish / demolished material out of MD land complete all as specified.
Supply and providing water proofing treatment with polyster based water waterproofing membrane standard water proofing membrane 3 mm thick, wt not less than 3.5 kg/ sqm having 10 years guarantee for water tightness all as specified and directed and described as under : (a) Prepartion of RCC roof surface and applying one coat of polymer modified bitumen 85/25 @ 1.2 Kg/Sqm over a coat of polymer primer @ 0.30 Kg/Sqm including cleaning surface, all as per manufacture's specification complete all as specified and directed. (b) Supply & Providing APP based polyster based water waterproofing membrane minimum weighing 3.5kg/sqm and minimum 3.mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced/ torch application of membrane with 10 cm overlaps as required thereof, complete all as specified or as directed.
M & L for applying two coats of Bitumen based UV reflective and water proofing paint with aluminium finish over APP membrane and maximum coverage 8.00 Sqm per litre per coat on non assessible roof over APP membrance complete all as specified and directed.
S&F 18-20 mm thick green marble (of any type) work (table rubbed and polished) in riser & steps, cills and like jointed in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed and making V-groove 5mm wide and 5mm deep in 3 nos on the each tread in length wise 25mm centre to centre complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps , cooking platform, and other similar situations complete all as specified and directed
S&F in repairs Vitreous china wash down water closet pedestal pattern, duroplast slim seat cover, slow falling seat cover size 69x37x77CM complete, including connection to drain pipe etc complete all as specified and directed.
S&F in repair PVC low level flushing cistern 10 litres, valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, flushing pipe complete all as specified and directed.
S&F in repair fancy type chromium plated Stop valve (angle stop valve) type suitable for 15mm bore pipe complete all as specified and directed.
S&F in repair 15 mm dia bib tap fancy type chromium plated with flange quarter turn including all necessary fittings complete all as specified and directed.
S&F in repairs 450mm long PVC connection 15mm bore with PTMT nuts complete all as specified and directed.
Taking up or down 15 mm dia steel tubing and connections including cleaning for refixing or removal to store complete all as specified or as directed.
Taking up or down 20 mm dia steel tubing and connections including cleaning for refixing or removal to store complete all as specified or as directed.
Refixing 15mm dia old steel tubing with and including new fittings and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed.
Refixing 20mm dia old steel tubing with and including new fittings and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed.
S&F for 15mm bore galvanised steel water tubing with and including all fittings 'medium grade' and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
S&F for 20mm bore galvanised steel water tubing with and including all fittings 'medium grade' and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
S&F in repairs 100mmx100mm stainless steel 100 mm dia grating fixed complete all as specified and directed.
S&F in repair fancy type 20 mm dia brass chromium plated towel rack size 600mm long including a pair of brass bracket complete all as specified and directed.
S&F in repairs vitreous china ware coloured wash hand basin with padestal of size 55X40X82cm complete including PTMT Waste coupling ,waste pipe ,complete fixing arrangement and cutting for and pinning in walls & making good complete all as specifed and directed .
S & F in repair fancy type 150mm size square brass CP shower rose with or without swivel joints complete all as specified and as directed.
S&F in repairs Brass chromium plated wall mixer 2 in 1, 15mm for mixing hot & cold water inclding provision of over head shower, screwed down three joints to steel pipes or unions and plugging and screwed to walls incl necessary fitting complete all as specified and directed.
S&F in repairs health faucet 1.25 mtr long flexacle tube with 15 mm dia SS Braided connection tube with wall hook complete for ETWC incl necessary fitting complete all as specified and directed.
S&F in repair fancy type brass chromium plated soap dish of 160x160x90 mm complete all as specified and directed.
S&F in repair fancy type 15 mm bore brass chromium plated WHB mixer for mixing hot and cold water screwed down for iron pipe and fixed to WHB including taking out existing mixer from old WHB complete all as specified and directed.
S & F low density polyethene pipes (LDPE) 32mm of pressure rating 6 Kg/cm2 fixed to walls complete all as specified and directed.
S&F in repairs mild steel chromium plated Curtain Rod 25 mm dia of approved quality with two number decorative design as approved brackets fixed in brick/concrete wall and same finished knobs on each end of curtain rod all as directed and specified.
Dismantling water tanks and removing to store capacity exc. 250 liter but n exc 500 complete all as specified and directed.
S & F 250 ltrs capacity rotational moulded polythylene triple layered water storage tanks white in colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
S&F 15mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed (Minimum weight 210 gms complete all as specified and directed.
S&F in repairs of 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F Mild steel OHT cage, bands, straps, supports or stay, for rain water, ventilating pipes including bolts if reqd, hooks (stay) heavy for large gates hook and pintle large hasps and staple, chains hand made sliding bolts clamps, hold fasts wall ties etc etc hooks for hanging fans plain angle cleats for securing purlins to wood truss or rafter, knee piece inserts, two way and three way straps, plate washer and similar small articles confirming to Fe-290 Gde - E-165 complete all as specified and directed.
Taking up or down AC/PVC rain water pipe, soil/waste/vent pipe of any size with fittings etc. complete all as specified and directed.
S & F PVC (SWR) 110 mm dia soil waste or rainwater drainage pipes single socketed in any length with rubber ring joint laid in floor or fixed on wall allcomplete all as specified and directed.
S & F PVC (SWR) 110 mm bore bends complete all as specified and directed.
S&F in repair PVC (SWR) floor trap/multi floor trap with grating including jointing with solvent cement floor trap 75 mm dia outlet plain including jointing to waste pipe fixed in cement concrete (1:2:4), type B-1 complete all as specified and directed.
S&F in repair PVC (SWR) 75 mm bore soil, waste or rainwater pipes single socketed in any length with rubber ring joints fixed to wall and floor with necessary fitting complete all as specified and as directed.
S&F in repairs PVC 100mm bore Y-Junction piece single (equal or unequal) ordinary or inverted (spigot or shocket type) or with parallel branches with oval access door complete all as specified and directed.
S&F PVC 100mm bore branch piece single (equal or unequal) ordinary or inverted (spigot or shocket type) or with parallel branches with oval access door complete all as specified and directed.
S&F PVC 100mm bore bend(any radius) diminising pieces or tapers (large bore measured) oval access door complete all as specified and directed.
S&F PVC 75 mm bore branch piece single (equal or unequal) ordinary or inverted (spigot or shocket type) or with parallel branches with oval access door complete all as specified and directed.
S&F Spun iron soil,waste and vent, 75 mm bore in any length with or without ear with cement joint fixed to wall complete all as specified and directed.
S&F 75mm bore PVC bends (any radius) diminishing pieces or tapers (larger bore mesured) with oval access door complete all as specified and directed.
S&F in repairs 75 mm bore PVC cowl complete all as specified and directed.
S&F powder coated aluminium sliding windows frame with movable shutter (sliding on minimum two PVC roller of best quality) for each shutter on three tracks with stainless steel mosquito proofing and glazing shutter and including 5.50 mm thick figured glass & stainless steel wire mesh fixed with neoprene rubber gasket with aluminium beading, clipsa, frame made with aluminium section as appended below- (i) Window frame :68.4x38mm X 1.15 mm thick for three tracks. (ii) Top/bottom rail and style / rail of shutter : 15x37.5x1.15 mm thick and over. (iii) Aluminium beading - 0.7mm thick (iv) stainless steel wire cloth 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed in aluminium window or along with F/Y section fixed with aluminium wire staples complete. (v) Aluminium fittings such as aluminium suitable handle with auto interlock cap with suitable size . (vi) Making good of wall surfaces with silicon to match with existing surfaces complete all as specified and directed.
S & F for aluminium glossy finish hat peg set of five tier with necessary fitting complete all as specified and directed.
S&F for mild steel window grills box type framed work as in window guard bars, grills or forged into spikes, framed balusters, walkway railing and similar work including welding, FE-290 grade E-165 complete all as specfied and directed.
S&F sheet glass 4 mm thick ordinary quality and glazing with oil putty in square exc 0.5 Sqm each pane complete all as specified and directed.
S&F for Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays for 75mm dia pipe, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
S&F for Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays for 100mm dia pipe, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
S&F for computerised reflective letter / bldg number on ACP sheet (size 45 cm x 45 cm) and fixing with 04 nos of screw, rawal plug etc on wall in front of building complete all as specified and directed.
Dismatling of RCC jalli complete all as specified and directed.
M & L for 25 mm thick (measured solid) Providing precast cement concrete louvres and jallies as in?cluding all mouldings and set in CM 1:4 but excluding frame Note-Pre cast frame shall be measured and paid separately)
M&L for Machine pressed precast conctete interlocking paver block ISI marked with gray cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade over 25mm thick sand cushioning including watering and consolidation incl dismantling of existing tiles complete all specified and directed.
S&F 32mm dia GI pipe, medium grade as in spout pipe complete all as specified and directed.
M&L 25mm thick cement concrete 1:2:4, type B1 (using 20mm graded stone aggregate) as in floor finishes even and fair to receive floor tiles/top layer of floor complete all as specified and directed.
S&F in repair vitreous china squatting pan of orrissa pattern long pan size 580 x 440 mm white with "P"or "S" trap size 100 mm dia front or back inlet and integral foot rest any pattern (excluding flushing cistern) including provn of lime concrete bedding (1:2:5), minimum 150mm all round and finish just below level of rim of pan complete all as specified and directed.
S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x330mm x160mm complete all as specified and as directed
S&F in repairs 50 mm x 32 mm dia chromium plated waste fitting special size suitable for stainless steel sinks including PVC flexible waste pipe of approved quality complete all as specified and directed.
S&F in repair fancy type 15 mm bore brass chromium plated pillar tap screwed down for iron pipe and fixed to WHB including taking out existing mixer from old WHB complete all as specified and directed.
Dismantling water tanks and removing to store capacity exc 500 and not exc.1000 litres complete all as specified and directed.
S & F 500 ltrs capacity rotational moulded polythylene triple layered water storage tanks white in colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
S & F 1000 ltrs capacity rotational moulded polythylene triple layered water storage tanks white in colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
S&F steel windows with pressed steel frame of size 95 x 45mm (thickness of PBI Sheet 1.25mm) side hung shutter including box type hinges with steel handle and steel peg stay with glazed openable shutter with glazing bar (open out side ) and wire gauged openable shutter without glazing bar (open inside ) dovetailed or welded complete all as per DRG No TD /088 dt 07 Jan 2002 with and including PCC 1:3:6 type C0 for filling of frame complete all as specified and directed. (Note -(i)Two shutter ie wire guaged and glazed shall be fixed in one composite frame and both shutter shall be measured as one unit (ii) rate of filling pcc in framed deemed to be included in unit quoted rates..(iii) MS grill shall be measured and paid seperatly under relevent item of schedule.
Dismatling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
M&L for pre- painted galvalume aluminum zinc coating GI based profile sheet( Manglore pattern) 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L for pre- painted galvalume aluminum zinc coating GI based plain sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Dismantling framed timber scantlings 40 sq. cm and over in section, in any complete all as specified and directed.
Dismantling unframed timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section, in any position complete all as specified and directed.
S&F steel work in tubular hollow rectangle trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade Fe-410 gde st- 240 complete all as specified and directed.
Dismatling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
S&F false ceiling at all heights with GRG (Glass FibreReinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture,design and patterns having moisture content less than 2%, humidity resistanceof 99%, NRC0.50 to 0.75 as per IS8225:1987, Noncombustible as per BS 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter?locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main?T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm ,suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000 mm length and L?shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws complete all as specified and directed.
M&L for 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in floor and finished even and fair (levelling course) complete all as specified and directed.
S&F 300 mm size, MS ordinary rat tail rod pattern springs including roller and roller plate complete including fixed to wooden and steel chowkats complete all as specified and directed.
M&L for 16-18 mm thick Granite (Z- black colour only) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. stone including grinding, polishing, rounding edges of stone slabs and 15mm screed bed in cement mortar 1:6 including dismantling of existing tiles, hearting etc complete all as specified and directed.
S&F for Steel ventilator with top hung shutter including hinges, steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F for 3 mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed.
S&F 150 mm long floor door stopper of aluminum alloy body and tongue, brass body and tongue with hard drawn steel spring fixed in floor complete all as specified and directed.
Precast cement concrete type C1 , 1:3:6 (Using 20 mm graded stone aggregate) in bonders stone etc. (of any section indicated),with plain fair faces,including chamfers,weatherings,throating and setting in cement mortar 1:6 complete with joints to match. complete all as specified and as directed.
M & L for chicken wire mesh of 10 mm aperture and 0.63 mm dia and 200 mm wide be fixed with rawlplug at 200 mm intravel over the cracked walls surfaces and cracks shall be cut into V shape & filled epoxy crack seal before the plastering to act as reinforcement for the plaster complete all as specified and directed.
S & F for Steel rolling shutters, thickness of lath 1.25 mm with out ball bearing, as specified including top cover, an?choring rod, hasp and staple and one shop coat of primer erected in position a indicated , push pull or manual type complete all as specified and directed.
M & L for 75 mm thick plain cement concrete Type D2, 1:4:8 ( using 40 mm graded stone aggregate) as in sub base etc complete all as specified and directed.
M & L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed.
Dimantlaing of bricks (laid flat of or on edge) ore brick tiles in floors, channels, kerbs, aprons etc (each layer) in dry laid complete all as sepecified and directed.
M &L for 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed.
M&L for chequred cement concrete tiles 25cmx25cmx22mm thick with grey cement and no pigment set jointed and pointed in neat cement slurry in floors complete all sepecified and directed.
Excavating in trenches, n exc 1.5m wide and n exc 1.5m depth for foundation etc or for shafts wells, cesspits, manholes, pier holes etc not exc 10 sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all specified and directed.
M & L for PCC type D2, 1:4:8 (using 40mm graded stone aggregate as in foundatin, mass filling complete all as specified and directed.
M&L Brick work with fly ash bricks (old size) as per IS 12894 -2002 straight or curved on plan exc 6 m mean radius built in cement mortar 1:4, complete all as specified and directed.
Returning filling including spreading leveling watering and well ramming in layers not exc 25cm in soft/loose soil complete all as specified and directed.
Removing excavated Soil materail n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Taking down carefully aluminium point wiring any type including battens if any except for ceiling or where not feasible for light/ fan//bell/socket or power and including unscrewing from board, fitting and fixture such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified.
Taking down carefully UNSV main switch DBs of any description of an size in any position complete all as specified.
Taking down submain wiring including all accessories complete all as specified and directed.
Material and labour for point wiring with single core PVC sheathed 1100 volt grade FRLSH cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, with all conduit accessories, screws, rawl plugs (concealed conduit wiring in walls and casing capping on ceiling or roof) including pressed steel terminal sunken boxes and covered with 3 mm thick plastic laminated sheet cover of suitable size with new brass screws for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC sheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for:- (a) One light / fan/ exhaust fan point controlled by one switch.
(b) One 5 pin 5 Amp switch socket out let point on an independent board complete all as specified and directed.
(c) One 5 pin 5 Amp socket out let point controlled by one switch on same board complete all as specified and directed.
(d) One buzzer/ bell point controlled by one push button on the same board with other switches or independent
(e ) One light point controlled by two switch 2 way complete all as specified and directed.
All as per item 164 here in before but for one 15/16 Amp 6 Pin switch socket out let independent with 4 Sqmm FRLSH (Nominal Area) PVC unsheathed copper conductor single core multistranded incl 4.0 sq mm FRLSH PVC copper conductor single core used as earth continuity conductoe complete all as specified.complete all as specified.
S&F switch piano flush type 5/6 Amp single pole one way complete all as specified and directed.
S&F socket out let 2 in 1 flush type 5/6 Amp 5 Pin complete complete all as specified and directed.
S&Fswitch piano type 15/16 Amp flush type 240 Volt complete all as specified and directed.
S&Fsocket out let 6 Pin 2 in 1, 5/15-6/16 Amp flush type 240 Volt complete all as specified and directed.
S&F bell push flush type 5/6 Amp complete all as specified and directed.
S&F switch piano flush type 15/16 Amp single pole two way complete all as specified and directed.
S&F bell ding dong musical ,AC, 230 Volt, single pole complete all as specified and directed.
Supply and Fixing ceiling rose PVC / Poly carbonate, Isolated body, three terminal AC 230 volts complete all as specified and directed.
Supply and fix in replacement of fan regulator 150 watts electronic flush socket type with five stepped range hum free complete all as specified and directed .
S&F in replacement LED light fitting of 1 x 10 watt T-5 lamp type with electronic ballast of suitable capacity, clear acrylic cover including mounting on wall complete all as specified and directed.
Supply and fixing surface mounting LED light fitting aluminium extruded T-5 batten , 20 Watt, 4 feet including connection with 23/0.0076 three core PVC flexible cable etc complete all as specified and directed.
S&F indoor decorative LED City-3 light fitting suitable for & including single 9 Watt LED lamp with polycarbonate body with upper globe complete all as specified and directed.
Taking down carefully ceiling fan and keeping in safe custody for refixing at site after bldg repair including Painting of ceiling fans complete, with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. painting complete all as specified and directed.
Supply & Fixing security light fitting, LED type, 20 Watt, 6000 K, pressure die cast housing with prismatic polycarbonate diffuser & indvl LEDs as light source with integrated electronic driver complete with M&L GI pipe mounting bracket of size 25/32 mm dia and 1.20 m long fixed to wall with and including nut, bolts and GI clamps of size 50 x 6 mm as required including two coats of synthetic enameled paint over a coat of primer and making connection with three core 23/.0076 rubber insulated copper cable from ceiling rose to connector of street light complete all as specified and directed.
M&L for sub main wiring with two single core 6.0 Sqmm (FRLSH) copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including 4.0 Sqmm (FRLSH) PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dollycomplete all as specified and directed.. ( Note : Two runs of 6.0 sqmm (FRLSH) and one run of 6.0 sqmm (FRLSH) copper conductor shall be measured as one unit length.)
S&F in repair MCB SPN 40 Amp, 10 KA 240 volt complete all as specified and directed
S&F in repair MCB single pole 6 to 32 Amp 240 Volt 'B' curve 10 KA complete all as specified and directed .
S&F in repair MCCB Triple pole and neutral 160 Amps 415 Volt 'C' curve 10 KA complete all as specified and directed ..
S&F in repair MCCB Triple pole and neutral 100 Amps 415 Volt 'C' curve 10 KA complete all as specified and directed ..
Supply and fix flush sheet metal enclosure SPN DB 8 way with double door IP-42 protection detachable gland plates, flush mounting for MCB fitted with bus bar , earth bar and neutral links complete including taking down old unsv all as specified and directed.
Supply and fix flush sheet metal enclosure V TPN DB 4 way 415 V with double door protection detachable gland plates, flush mounting for provn of MCCB 160 Amps fitted with bus bar, earth bar and neutral links complete including taking down old unsv all as specified and directed.
Servicing complete Solar Water Systems ( Tata BP) by pouring the anti-corrosion/anti scaling agent solution in the make up tank to clear the water circulated pipes , descalling of solar collectors with required concentration descaling sulotion with the help of 0.5 HP descaling pump and PVC pipe for recirculating the descaling solution Complete of heat convertors sets upto 3 glasses of capacity 300 LPD and drain out the solution by opening the nuts and bolts of dead plate placed at the end of the system and opening SS flange by taking out of old rusted SS nuts and bolts and rubber gasket at inlet and out let Position of solar collectors. replacement of parts such as gasket , hex nuts, bolt washers etc incl inspection and checking of fault in solar water heating system of 300 LPD including water supply and electric supply circuit complete and make the system serviceable including cleaning of toughned glass first with detergent and after that with coline solution as per site requirement complete all as specified and directed.
M&L One coat painting to existing steel structure of solar water heating system 500 Ltrs capacity including all supports with super enameled paint of approved colour all as specified and directed.
Supply & Fixing in replacement heating elements of Capacity not less than 4 KW for Solar water system of any capacity including making connections complete all as specified and directed .
Material & Labour for gas welding of leaking Copper tubes of solar collectors at different places complete all as specefied and as directed.
Supply and fixing in replacement Gun metal gate valve ISI Marked with crutch or butter fly handle for 20 mm dia bore all as specified and directed.
Taking down unserviceable PVC water storage Tank and supply and fixing in replacement of Rotational moulded polyethylene water storage tank cylinderical vertical with closed top hoisted and fixed of 250 ltrs capacity including all inlet,outlet,overflow,washout etc system complete all as specified and directed (Note : (i) The water storage tank shall be three layered HDPE tank moulded to seam-less perfection of rotational moulding process polythylene and shall be certified fit for potable water.)
Taking down unserviceable hot water water storage tank made out of SS with appropriate size and suitable for accomodate 300 Ltr cap incl insulated with glass wool and wrapping with aluminium sheet duly rivetted vertical with closed top hoisted and fixed including all inlet,outlet,overflow,washout etc system complete with all inlet out let connection complete all as specified and directed.
Supply and fixing in replacement Insulated Hot water G I pipe medium grade, ISI marked, 15 mm bore with including all fittings and fixing arrangements by taking out insulation & re- insulation as per manufacturer's recommendations all as specified and directed. (NOTE : New insulation will be done with proper packing of galss wool,wire mesh and stainless steel SS 304 where required as per site requirement, insulation will be carried out with no extra cost on the item of schedule and will be measured and paid under this item of schedule).
Material & Labour for earthing complete including taking out old unsv and replace with galvanised steel earth plate 600x600x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using 4 mm dia GI wire as earth wire electrode moulded and rivetted to earth plate at one end and connected to main switch/ control switches of buildings at another end, GI earth wire encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto main switch board of building including 20 dia bore GI pipe 'light grade' as water pipe from earth chamber and including excavation and earth work, PCC 1:3:6 type C1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced and as per Electrical Plate No. 3 of SSR Part-I complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Taking down carefully Exhaust fan and keeping in safe custody for reuse at site after bldg repair incl Painting of ex fan complete, with synthetic enamel paint smoke grey spraying including filling cavities with filler, one coat after cleaning all dust etc. painting and minor repairs etc complete all as specified and directed.
M&L for sub main wiring with two single core 4.0 Sqmm (FRLSH) copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including 4.0 Sqmm (FRLSH) PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. Note :- Two runs of 4.0 sqmm (FRLSH) and one run of 4 sqmm (FRLSH) copper conductor shall be measured as one unit length.)
Taking down existing geyser carefully and re fixing the same after necessary repair and fixing arrangement, painting complete all as spd and directed.
SM & L for replacement of lamp holder, PVC / Poly carbonate, insulated body modular type with back plate batten/angle type for batten fittings complete all as specified and & directed Note : Tenderers may note that amount of credit Rs 3,07,596.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
Shikhar ji Enterprises
The new hut furnitures
BHARAT ELECTRICAL TRADERS
yash enterprises
Ikrar khan & co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .