| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC | L1 | Accepted-AOC L1 |
| Sl No | Description | Qty | Unit | HARIPRASAD BK L1 |
|---|---|---|---|---|
| 1.002024-25 Sustainability support to Kuntar WSS | ||||
| 1.01 | 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | 17.64 | sqm | 308 ₹5,433.12 Lowest |
| 1.02 | 13.37.1 : White washing with lime to give an even shade:New work (three or more coats) | 185.96 | sqm | 33 ₹6,136.75 Lowest |
| 1.03 | 13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer | 185.96 | sqm | 69 ₹12,831.38 Lowest |
| 1.04 | 13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work | 185.96 | sqm | 148 ₹27,522.38 Lowest |
| 1.05 | 13.71 : Lettering with black Japan pint of approved brand and manufacture | 1,500 | per Letter per cm height | 5.2 ₹7,800 Lowest |
| 1.06 | 22.23.2 : Providing and applying integral crystalline slurry of hydrophilic in nature for
waterproofing treatment to the RCC structures like retaining walls of the basement,
water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels
/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts
integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts
integral crystalline slurry : 1 part water) for horizontal surfaces and applying the
same from negative (internal) side with the help of synthetic fiber brush. The material
shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing
permeability of concrete by more than 90% compared with control concrete as per
DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline
slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work
shall be carried out all complete as per specification and the direction of the engineerin-
charge. The product performance shall carry guarantee for 10 years against any
leakage.For horizontal surface one coat @1.10 kg per sqm. | 68 | sqm | 420 ₹28,560 Lowest |
| 1.07 | 10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works | 298 | kg | 140 ₹41,720 Lowest |
| 2.00Sustainability Support to Vivekananda WSS | ||||
| 2.01 | od51918/2024_2025 : Suitable HP (IS; 8034) borewell submerssible 3phase electric driven motor pumpset working at 360 voltage with bronze impeller and stainless steel shaft with suitable ISI marked accessories such as starter(best quality ISI marked fully automatic electronic Star Delta ), main switch ,fuse, capacitor, ELCB, adequate length of best quality suitable size flat submerssible cable, reflux valve, sluice valve, pressure gauge, earthing materialsconforming to IS 3043/2000 as amended to date, ammeter, volt meter, selector switch, flickering lamps, dry running preventer cum no voltage wire, conveying and erecting the motor pumpset and panel board and giving all connections, earthing etc. as per KSEB/EI rules and regulations. Conveying and fixing suitable GI pipe medium pipe as suction and delivering pipes including connections with pumpset delivery to the common pumping main of suitable size using suitable T/Y connections etc,.Trial run should be given for 7 days. Any documentation required for proper electric connection shall be arranged by the contractor at their own cost etc. complete as per direction of site in charge of the work. | 2 | no | 18,134.5 ₹36,269 Lowest |
Tender Value
₹15.2 L
EMD Value
₹37,989
Closing Date
26 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Regional Project Director
2nd Floor, Bldg.No.3/253, Near AKG Hospital, Talap, Kannur
Sustainability Support to Kuntar WSS, Vivekanda WSS, Kaithode SC WSS, Koyakudlu SC WSS in Karadukka GP
2025_KRWSA_769637_1
9/ KRWSA/KNR/MT/KDK/SUS/24-25/RT2
Open Tender
Civil Works - Water Works
Item Rate
90 days
Karadka Grama Panchayath Kasaragod District
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,500
Yes
₹37,989
Regional Project Management Unit, KRWSA, Kannur
16 Sept 2025
17 Jun 2025
28 Jun 2025
17 Jun 2025
26 Jun 2025
17 Jun 2025
17 Jun 2025 - 26 Jun 2025
19 Jun 2025
Amount
2024-25 Sustainability support to Kuntar WSS
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.37.1 : White washing with lime to give an even shade:New work (three or more coats)
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.71 : Lettering with black Japan pint of approved brand and manufacture
22.23.2 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Sustainability Support to Vivekananda WSS
18.17.6 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore
13.37.1 : White washing with lime to give an even shade:New work (three or more coats)
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.71 : Lettering with black Japan pint of approved brand and manufacture
22.23.2 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.
100.98.192 : Supply of PE Pipe, PE100, PN16, 63mm dia, conforming to IS 4984/2016.
100.9.6 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 63 mm nominal outer dia pipes.
Providing and fixing of good quality water level indicater with proper markings
2024-25 Sustainability support to Kaithode SC WSS in Karadukka GP
od60624/2024_2025 : Supplying and fixing Water Meter, Indian Standard, Class B, Multijet, 15mm ( 1/2 inch )<br>including the Surface box in the existing house connection and making the loop for fixing<br>the water meter - tracing, locating and exposing the service line at the required place<br>including earth work excavation, cutting and removing the service line portion and making<br>the connection functional including cost of all specials, labour charges etc complete.<br>
100.1.1 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil (Ref. Item No. 2.10.1 of DSR)
100.98.229 : Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 20mm.
100.98.231 : Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 32mm Dia.
100.98.233 : Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 50mm Dia.
100.98.235 : Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 75mm Dia.
100.9.1 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 20 mm nominal outer dia pipes.
100.9.3 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 32 mm nominal outer dia pipes.
100.9.5 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials) 50 mm nominal outer dia pipes.
100.9.7 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 75 mm nominal outer dia pipes.
18.12.7 : Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work65 mm dia nominal bore
18.17.6 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore
100.98.192 : Supply of PE Pipe, PE100, PN16, 63mm dia, conforming to IS 4984/2016.
Tank maintanace works
13.37.1 : White washing with lime to give an even shade:New work (three or more coats)
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.71 : Lettering with black Japan pint of approved brand and manufacture
22.23.2 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.
Pump House
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
Hydrogeological survey
Drilling of borewell of caising pipe 180mm
Good quality cable for motor
Providing and fixing MS sheet,sheet frame , roof sheet for pump house
2024-25 Sustainability support to Koyakudlu SC WSS
od60462/2024_2025 : Supplying and fixing Water Meter, Indian Standard, Class B, Multijet, 15mm ( 1/2 inch )<br>including the Surface box in the existing house connection and making the loop for fixing<br>the water meter - tracing, locating and exposing the service line at the required place<br>including earth work excavation, cutting and removing the service line portion and making<br>the connection functional including cost of all specials, labour charges etc complete.<br>
100.60.12.3.2 : Providing 15mm PVC Tap in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of consumables, hire charges for tools and labour charges etc. complete, but excluding cost of materials and as per the direction of departmental officers.
100.98.234 : Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 63mm Dia.
100.9.6 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 63 mm nominal outer dia pipes.
100.98.192 : Supply of PE Pipe, PE100, PN16, 63mm dia, conforming to IS 4984/2016.
Pump Houe
12.1.2 : Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.80 mm thick with zinc coating less than 275 gm/m2
4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
50.10.1 : Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
Providing and fixing good quality ISI marked HDPE tank including foundation
Drilling of bore well of caising pipe dia 180mm
Providing and fixing good quality cable for motor
Hydrogeological survey
Bidder Name
HARIPRASAD BK
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1255531.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .