Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.9 LAdmitted-Finance KOTHENALLOOR KAKKADA P O THIRUVANANTHAPURAM 695505 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695505 | L1 | Admitted-Finance | |
| 2 | L2₹50.9 L+₹1,555.39 (0.03%)Admitted-Finance 24 234 2 NEAR VYDHYUTHI BHAVAN KOTTAPPURAM ROAD PUNKUNNAM THRISSUR KERALA 680002 | THRISSUR | KERALA | 680002 | L2 | Admitted-Finance | |
| 3 | L3₹50.9 L+₹3,110.78 (0.06%)Admitted-Finance 18 398A MUNDAKAYAM MUNDAKKAYAM MUNDAKAYAM KOTTAYAM KERALA 686513 | KOTTAYAM | KERALA | 686513 | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | A ONE AGENCIES L1 | MERKURY ELECTRICAL CORPORATION L2 | KALLOOR ELECTRONICS AND LIGHTING PVT LTD L3 |
|---|---|---|---|---|---|---|
| 1.00CIVIL WORKS | ||||||
| 1.00 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil | 52.4 | cum | 256 ₹13,414.4 Lowest | 256.5 ₹13,440.6 | 257 ₹13,466.8 |
| 1.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) | 32.46 | cum | 7,931 ₹2,57,440.26 Lowest | 7,931.5 ₹2,57,456.49 | 7,932 ₹2,57,472.72 |
| 1.00 | Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete | 81.12 | sqm | 385 ₹31,231.2 Lowest | 385.5 ₹31,271.76 | 386 ₹31,312.32 |
| 1.00 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | 1,387.84 | kilogram | 111 ₹1,54,050.24 Lowest | 111.5 ₹1,54,744.16 | 112 ₹1,55,438.08 |
| 1.00 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | 21.72 | cum | 9,962 ₹2,16,374.64 Lowest | 9,962.5 ₹2,16,385.5 | 9,963 ₹2,16,396.36 |
| 1.01 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited.layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. | 55.24 | cum | 317 ₹17,511.08 Lowest | 317.5 ₹17,538.7 | 318 ₹17,566.32 |
| 2.00ELECTRFICATION WORKS | ||||||
| 2.00 | Supply, installation, testing and commissioning of Outdoor Floor / Wall Mounting Cubical Type KSEBL Metering Panel with Double Door and Canopy suitable for 240 V, Single Phase, 2 Wire 50 Hz AC supply system having sufficient front surface area fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame works and covers, 2 mm thick for gland plates, cleaning and finishing complete with 7 tank process for Powder Coating in approved shade and then provided with Clear Coating, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 12 mm x 3 mm at the rear with 2 Nos. earth stud and control wiring with 2.5 / 1.5 Sq.mm FRLS (Flame Retardant Low Smoke) or HRFR (Heat Resistant Flame Retardant) PVC insulated single core copper conductor cables, cable alleys etc. complete as required. The panel shall conform to the Electrical Inspectorate and KSEBL standards and it shall only be manufactured after getting approval from the Engineer-in-charge and the Consultant. INCOMER
1 Nos - Provision for Fixing Single Phase Energy Meter
1 Nos - 32A Bakelite Fuse Units with HRC Fuse of Suitable Rating 1 Nos - 32A Neutral Link
1 Nos - 25A/32A 10kA DP C Curve MCB
There shall be Separate Compartment for Energy Meter and Fuse Units/Neutral Link with KSEBL Sealing Provision.
SURGE PROTECTION DEVICE
1 Nos - 2 Module DIN Rail Mounting Type 1 + Type 2 / Class 1 + Class II 100kA SPD on the Incoming / Outgoing Side of Incomer MCB along with Green and Red Indication Lamps with Control MCBs [The connections to RYB Phases, Neutral and Earth shall be done using 16 Sq.mm FRLS (Flame Retardant Low Smoke) or HRFR (Heat Resistant Flame Retardant) PVC insulated single core copper conductor cables with less than 0.45m in length]
OUTGOING
1 Nos - Outdoor / Street Light Compartment with 6A/10A 10kA DP C Curve MCB, 25A 30mA DP RCCB, 9A/12A TP AC3 Duty Contactor with Auxiliary Contacts, 24Hour Digital Timer Switch, Auto - Manual Selector Switch (2 Pole 2 Way), ON (Red), OFF (Green) Push Buttons and ON (Red), OFF (Red) Indication lamps with Control MCBs | 40 | no | 35,059 ₹14,02,360 Lowest | 35,059.5 ₹14,02,380 | 35,060 ₹14,02,400 |
| 2.00 | Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters | 40 | each | 30,109 ₹12,04,360 Lowest | 30,109.5 ₹12,04,380 | 30,110 ₹12,04,400 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
8 Aug 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ENGINEER (PROJECTS)
KEL MAMALA KOCHI
MLA ADS (2024-25) - SITC OF 8 M MINIMAST LIGHTS AT VARIOUS LOCATIONS IN KUNNATHUR CONSTITUENCY
2025_KEL_778802_1
KEL/KMEP/EPROC/019/2025-26
Open Tender
Electrical Works
Item Rate
KEL MAMALA
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,500
₹50,000
Yes
11 Aug 2025
24 Jul 2025
9 Aug 2025
24 Jul 2025
8 Aug 2025
24 Jul 2025
24 Jul 2025 - 8 Aug 2025
Amount
CIVIL WORKS
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited.layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
ELECTRFICATION WORKS
Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
Installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
Supply and laying of XLPE insulated and PVC sheathed armoured Aluminium power cable of 1.1 kV grade of the following sizes in the existing excavated trenches, built up trenches and pulling through existing pipes including all minor civil works etc. complete as required 2 Core 10 Sq.mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp
Supply and laying of 1.5 Sq.mm 1.1kV Grade Three Core Round Insulated Copper Conductor and Sheathed Flexible cable with compact construction and high insulation resistance. The cable shall have the specifications of Standard FRLS PVC Insulation, FRLS Sheathing in accordance with IS 694, BS 6500, IEC 60227, DIN VDE-0281, IEC 60754-I IEC, 60332-I, BS 4066-I, ASTMD 2843, ASTMD 2863, Conductor Class 5, Number of Conductor Strands 30, Nominal Diameter of Conductor Strands 0.25mm, Nominal Thickness of Insulation 0.6mm, Nominal Thickness of Sheath 0.9mm, Approximate Overall Diameter 8.2mm, AC Current Rating of 18A, Voltage Drop/Amp/Metre for Single Phase AC 31mV, Maximum Conductor Resistance at 20 Deg.C 13.3 Ohms/Km etc. complete as required
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
Supply and providing gland earthing using Gland Earthing Clips / Clamps for following size of PVC insulated and PVC sheathed / XLPE Aluminium conductor cable of 1.1 kV grade etc. complete as required 2 X 10 Sq.mm
Excavation of all types of soils for the laying of PVC insulated and PVC sheathed / XLPE Aluminium or Copper conductor cable, GI / DWC HDPE / RCC / PVC / Conduit Pipes, Earthing conductors to the required width and depth up to and including 1.2m and back filling etc. complete as required. (The trench dimensions and specifications shall conform to CPWD / PWD, Electrical Inspectorate and KSEBL Standards)
Supply and providing earthing with ISI Marked Nickel Sealed Copper Bonded 20mm dia, 3.0m long Rod having 250 microns coating thickness with T clamp including Stainless Steel bolts, nuts, round and spring washers etc. and providing masonry enclosure with cover plate having locking arrangement with sufficient earthing compound etc. complete as required
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.06 mm GI conductor (8 SWG)
Supply and installation of 10 kg/cm2 PVC Pipes of the following sizes with all necessary accessories and laying in existing excavated trenches, built up trenches, clamping in built up trenches / walls / MS supports using Stainless Steel saddles and screws of which spacing between 30cm to 60cm including all minor civil works etc. complete as required Up to and including 40mm
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
Supply, fabrication and installation of Outdoor Floor / Wall Mounting Cubical Type KSEBL Metering Panel / PVC Pipe / Cable supports etc. using MS Angles, Flats and C Channels of adequate size painted with two coats of epoxy primer and two coats of black / grey / other approved shade epoxy paint. The scope also the includes the supply and installation of necessary rectangular / square plates, anchor fasteners, bolts, nuts, round and spring washers or screws etc. complete as required
Preparation and submission of application for Single Phase Connection along with drawings, detailed load schedule etc. and co-ordination with KSEBL for energization etc. complete as required. (*All Statutory fees for getting connection shall also come within the scope of the Contractor)
MERKURY ELECTRICAL CORPORATION (BID ID -2277403)
KALLOOR ELECTRONICS AND LIGHTING PVT LTD (BID ID -2278521)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .