| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.1 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹16.3 L+₹1.6 L (11.0%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹16.7 L+₹2.1 L (14.0%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹17.9 L+₹3.2 L (21.6%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹18.0 L+₹3.3 L (22.2%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
27 Aug 2022, 6:00 pmClosed
GE SAMBA
GE SAMBA
REPAIR TO HARD STANDING SECURITY WALL COMPOUND WALL INCLUDING PERIODICAL SERVICES AND CONNECTED ITEMS IN ZONE I AREA UNDER GE SAMBA
2022_MES_541810_1
GE/SMB/T-23/2022-23
Open Tender
Civil Works
Item Rate
180 days
Samba
REF NIT
8 documents required · 8 mandatory
₹500
Yes
GE SAMBA
₹40,000
Yes
5 Nov 2022
30 Jul 2022
29 Aug 2022
30 Jul 2022
27 Aug 2022
13 Aug 2022
30 Jul 2022 - 1 Aug 2022
Amount
Demolition of brick work or stone masonry, built in cement mortar incl all quoins, arches pillars etc complete all as specified and directed.
Taking down cement plaster on brick/concrete or stone walls, ceiling, etc, including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
Dismantling fencing wire mesh any type, Complete all as specified and as directed .
Dismantling posts or struts (Wood, steel or RCC) any section including taking out embeded portion by demolition of cement concrete in fdn and making good the disturbed portion of ground, Complete all as specified and as directed .
Demolition of plain cement concrete in ground floors or above ground floor and paving n.exc 15 cm thickness (Below or above ground level), Complete all as specified and as directed .
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Brick work with old size sub class 'B' burnt bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan exc. 6 m mean radius built in CM 1:4 , complete all as specified and directed.
Brick work with old size sub class 'B' burnt bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan exc. 6 m mean radius built in CM 1:4 but except brick, complete all as specified and directed.
Brick work with sub class 'B' burnt bricks having crushing strength not less than 75 Kg/Sqcm,straight or curved on plan to any radius in half thick brick wall built in CM 1:4 complete all as specified and as directed.
Brick work with sub class 'B' burnt bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan to any radius in half thick brick wall built in CM 1:4 but except brick complete all as specified and as directed.
Rendering 15 mm thick cement plaster in two layers 5 mm thick over and including 10 mm thick in CM 1:4 on brick work or concrete surfaces finished even and smooth without using extra cement ,complete all as specified and directed.
Machine pressed precast concrete interlocking paver block of any shape and size approved by EIC, ISI marked (IS:15658-2006) 60mm thick, M-35 grade (Medium Traffic), in paths and hardstanding,with grey cement and pigment, laid tightly over & including 50 mm thick dry sand cushion (compacted) and joints filled with dry sand, colour and pattern as approved by GE, complete all as specified and directed.
Pre-polished chequered cement concrete tiles of size 20 cm x 20cm x 25 mm thick / 25 cm x 25 cm x 25 mm thick, set & jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 20 mm thick cement screed bed in CM 1:4 complete all as specified and as directed.
PCC 1:3:6, 75 mm thick,Type C-2 (using 40mm graded crushed stone aggregates) as in sub base in paver blocks etc, complete all as specified and directed.
Plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates as in copings, kneelers, apex stones, bed plates, etc. and in similar works including weathering,slightly rounded or chamfered angles and throating and necessary form works,Complete all as specified and as directed .
Preparation of newly steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Preparation of old plastered surfaces of steel and applying one coat of synthetic enamel paint , complete all as specified and directed.
Galvansied 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining & fixing to any type of standard rails strain-ing bolts including securing or tying at cossing with and provn of galvanised mild steel wire, staples or steel pins, etc, complete all as specified and directed.
Galvansied 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining & fixing to any type of standard rails strain-ing bolts including securing or tying at cossing with and provn of galvanised mild steel wire, staples or steel pins, etc fixed in repair, complete all as specified and directed.
Restraining & resecuring including making good steples etc of Galvansied 2 strand, steel barbed wire with 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining & fixing to any type of standard rails strain-ing bolts including securing or tying at cossing with and provn of galvanised mild steel wire, complete all as specified and directed.
Preparation of old decorated brick/concrete/ plastered/unplastered surfaces of walls, Pillars, cornices etc by booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots, rubbing with sand paper and applying one coat of cement base paint on walls, pillars, cornices etc . complete all as specified and directed.
Preparation of newly plastered surfaces of walls etc and applying two coats of cement based paint over including priming plastered and other surfaces with alkali resistant priming paint , complete all as specified and directed.
25 mm thick cement concrete 1:2:4, Type B-1 (20 mm graded stone aggregate) as in sub-base of floor for tiles/Kota stone finished even & rough, complete all as specified and directed
Kota stone floor 18-22 mm thick, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer of 15 mm thick CM 1:6, including rubbing and polishing, complete all as specified and directed.
Kota stone skirting 18-22 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over rendering layer of 10 mm thick CM 1:4, including rubbing and polishing, complete all as specified and directed.
Excavation in post holes (or similar holes) each n.exc. 0.5 cum. in hard/dense soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc. 25 cm, watering and removing surplus soil to a distance not exc. 50 M and making good Complete all as specified and as directed .
PCC 1:3:6 Type C-2 ( using 40mm graded crushed stone aggregate) in foundations, filling and mass concrete, complete all as specified and directed.
Supply only chain link MS galvanisd fencing, any size or type complete all as specified and directed
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed
40 mm thick cement concrete 1:2:4, Type B-0 (12.5 mm graded crushedstone aggregate) as in floor finished even & smooth using extra cement, complete all as specified and directed
Glass dividing strips, 3 mm thick of 38 mm width inserted in position to confirm to design as in floor, complete all as specified and directed.
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth: for foundation etc or for shafts,wells, cesspits, manholes, pier holes, etc n exc 10 sqm on plan and n exc 1.5m in depth and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm, complete all as specified and directed.
Removng excavated material (soil) to a distance n. exc. 50m and depositing where directed at a level n exc 1.5m above the starting point,complete all as specified and directed.
RCC M-20 , Design mix(using 20 mm graded crushed stone aggregate) as in foundations including rafts footings, foundations beams, plinth beams for coloumns etc and mass concrete, complete all as specified and directed.
RCC M-20 , Design mix(using 20 mm graded crushed stone aggregate) as in walls, retaining walls and like any thickness, complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of coloumn raft beams, sides and soffits of foundations and plinth beams, and similar works, vertical or to better for rough finished flat surfaces, complete all as specified and directed.
Formwork to faces of walls, retaining walls, abutments, parapets and staircase, railing and similar work including attached pillasters, butteresses etc vertical or barter rough finished flat surfaces of concrete, complete all as specified and directed.
Mild steel TMT bars (Fe 500) 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
All as per above here in before but 8 mm dia and over upto and including 12 mm dia as in striups, spacers and binders.
M S Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and as directed.
Concertina coil having dia 450 mm 600mm with blade thickness 0.47mm and core wire diameter 2.5mm with minimum zinc coating on wire minimum 275 GSM wt 14.63kg each coil fixed in repair. complete all as specified and directed.
Mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets or ms round bar etc(for securing wire mesh etc.) including all necessary drilling, bolting etc., and similar work conforming to Fe-290 Gde E-165, Complete all as specified and as directed .
12 mm dia mild screw bolts machine made with hexagonal or square heads at one end and screwed the other, or screwed on both ends each screwed ends to be fitted with washers and one hexagonal or square nut but length of bolt exc 5 cm but n.exc. 10 cm long, complete all as specified and directed.
MS round bar fixed to chain link fencing top and bottom, complete all as specified and directed.
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering. Doors etc to be prepared for hanging or sliding with and including either hooks and hings or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete, Fe-410 (Gde E-250) complete all as specified and directed.
Framed work such as grills, grating, etc. with ends of bars shoulders and/ or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work complete, conforming to Fe-410 (Gde E-250) complete all as specified and directed.
Dismantling of PVC(SWR) drain pipes upto 110 mm dia, jointed in cement mortar and taking out of trenches, if reuired, complete all as specified and directed .
PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
M/S RAJESH SHARMA & CO.
THAKUR BUILDERS AND CO
SINGH CONTRUCTION AND WORKS
BALI ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .