Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
11 Sept 2026, 6:00 pm
GE AF PHALODI
GE AF PHALODI PIN - 342301
REPAIR/MAINT TO WATER TREATMENT PLANT AND OTHER PUMP/MOTORS INCLUDING ITS STARTER PANEL BOARD UNDER AF STN PHALODI
2026_MES_785560_1
8826/A/E8
Open Tender
Civil Works
Item Rate
270 days
Air Force Station Phalodi
As per tender documents
7 documents required · 7 mandatory
₹500
GE (AF) Phalodi
₹50,000
Yes
20 Aug 2026
20 Aug 2026
14 Sept 2026
20 Aug 2026
11 Sept 2026
4 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes or for laying underground cable, pipe lines etc. in soft/ loose soil, complete all as specified & directed.
Note:- Any excavation in SDR/Loose soil/PCC/Hardstanding/Interlocking tiles/Bituminous pavement shall be carried out by manual mode only irrespective of Tech/Residential area. In case of mechanical excavation engaged by the contractor, any fault due to rupturing of communication/power/any other utility lines shall be rectified by appropriate joint as per direction of Engr-in-Charge/GE/Stn Auth as deemed fir and no extra cost will be paid in this respect. | 236.79 | CUBIC METER | - | - |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in soft / loose or hard dence soil complete all as specified and directed. | 174.04 | CUBIC METER | - | - |
| 3 | Removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. | 62.75 | CUBIC METER | - | - |
| 4 | Supply & spread unwashed dry river sand for sand cushioning and covering the under ground cable in trenches. (Note :- Punning thickness shall be measured.) | 42.12 | CUBIC METER | - | - |
| 5 | Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm across the cable in trenches complete all as specified and directed. | 3,355 | EACH | - | - |
| 6 | Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes of 70 sqmm 3.5 core complete all as specified and directed.
Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.
(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. | 150 | RUNNING METER | - | - |
| 7 | Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes of 50 sqmm 3.5 core complete all as specified and directed.
Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.
(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. | 100 | RUNNING METER | - | - |
| 8 | Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes of 35 sqmm 3.5 core complete all as specified and directed.
Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.
(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. | 80 | RUNNING METER | - | - |
| 9 | Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes of 25 sqmm 4 core complete all as specified and directed.
Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.
(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. | 70 | RUNNING METER | - | - |
| 10 | Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes of 16 sqmm 4 core complete all as specified and directed.
Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.
(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. | 150 | RUNNING METER | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
tender.pdf
Tender Documents • 1.12 MB
BOQ_880271.xls
BOQ • 0.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].