Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-AOC 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹31.0 L+₹24,460 (0.79%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹31.5 L+₹68,850 (2.24%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹32.5 L+₹1.7 L (5.66%)Rejected-Finance 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹35.2 L+₹4.4 L (14.4%)Rejected-Finance 255 VILLAGE UGRA POST OFFICE BARA AMBALA HARAYANA PIN 134003 | AMBALA | AMBALA | HARYANA | 134003 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
13 Apr 2024, 6:00 pmClosed
GE UTILITY AMBALA CANTT
GE UTILITY AMBALA CANTT 133001
REPAIR MAINT OF DESERT COOLERS REFRIGERATORS DEEP FREEZERS AND WATER COOLERS UNDER GE UTILITY AMBALA CANTT
2024_MES_646524_1
CA NO GE U AMB T 09 OF 2024-25
Open Tender
Civil Works
Item Rate
240 days
GE UTILITY AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹92,000
8 May 2024
14 Mar 2024
15 Apr 2024
14 Mar 2024
13 Apr 2024
30 Mar 2024
14 Mar 2024 - 21 Mar 2024
Amount
Comprehensive/preventive maintenance of the following Desert Coolers/ Water cooler / Refrigerator /Deep Freezer/Window / Split ACs different capacities by carrying out periodically maintenance of equipments including cleaning, lubrication, filling refrigerant gas etc, including chemical, anti moisture injection required for cleaning condenser/cooling coils complete and attending complaints all as specified and directed for following:
Desert Coolers of any capacity any size complaints as received and as directed by Engr-In-Charge.
Refrigerators any capacity any size complete and attending complaints as received and as directed by Engr-In-Charge.
Water cooler of any capacity any size complaints as received and as directed by Engr-In-Charge.
Deep freezers of any capacity any size complaints as received and as directed by Engr-In-Charge.
Split/Window ACs of any capacity any size complaints all as specified and as directed by Engr-In-Charge.
Note for items No 1.01 to 1.05 :- (i) Window / Split ACs / Water cooler / Refrigerator /Deep Freezer shall be taken from department on "as and where installed" basis, (ii) Window/ Split Acs are to be maintained for heating as well as cooling mode where installed all as specified and directed. (iii) The contractor shall ensure and asses at the site any initial maintenance required, to make the all Window/Split ACs/Water cooler / Refrigerator /Deep Freezer/Desert cooler in fully proper working condition. (iv) The date of periodical check will start from the date of commencement of work. (v) After completion of contract, contractor shall hand over the all Window / Split ACs / Water cooler / Refrigerator /Deep Freezer/Desert cooler in perfect running/functioning condition to the department. (vi) Contractor shall provide his authorised Cell/mobile No. and local address to contact and communicate the message for any breakdown and contractor's rep will visit the office twice a day (0930 Hrs and 1400 Hrs) to collect the day to day complaints of any nature/type. (vii) Penalty for not rectifying the defect in time(within 24 hrs)will be charged to contractor and the amount of penalty @ Rs 1000/- per complaint will deducted from the due payment of contract. (viii) Complaints will be treated as rectified only after user's "Satisfactory slip "duly signed by user including contact number will be produced by contractor to concerned JE E/M. (ix) Cost of attending day to day complaint is included in the rate quoted under this item, no extra payment for attending complaint shall be made. (x) Old material obtained from spares replaced under this item shall be contractor's property and will be measured as per credit schedule. (xi) Cost of minor spares i.e, insulation to copper tubes, soldering, internal wiring to cooling appliances are deemed to be included in the item rate, items other than mentioned will be measured and paid seperately, Refrigerant gas will only be measured when major items i.e, Comperessor, Condensing coil, Cooling coils are replaced, else cost of refrigerant gas required for less cooling, due to leakage etc will be deemed to be included in quoted rates. Labour required to carryout the maint / repairs for all repairs including testing and commissioning shall be deemed to be included in item rate as quoted by the contractor. (xii) Cost of T&P i.e, ladders, tools, brazing, welding, soldering required and transportation is deemed to be included in quoted rates. Supply only following items 2 to 62 to be fixed under Item No. 1.00 to 1.05 here-in-before:-
Supply only desert cooler body made of 20 gauge PGI sheet suitable for evaporative type desert cooler including side panel - 03 Nos of 20 gauge PGI sheet and water tank height 20 cm & grill with fins including electrical wiring and connection with ON/OFF switch piano type with distribution PVC cup and elbow, PVC flexible pipe connection , PVC cable 3 core - 3 Mtr with top plug 5 Amps - 01 No including duly painting the complete body internally and externally all side panels inner and outer side with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer complete all as specified and as directed.
Supply only Capacitor 4/5 MFD suitable for desert cooler/water cooler. Make- Usha/Spicex/Tibcon/Epcos
Supply only stop valve cast copper alloy screw down high pressure with crutch or butterfly handle screwed both ends for iron pipe 15 mm dia bore including complete all as specified and directed.
Supply only Thermostate for air conditioner capacity up to 2.0 Ton Make- INDOFOS or as approved by GE.
Supply only Starting Relay for AC capacity up to 2.0 ton Make- Renutralor or as approved by GE.
Supply only Operating Knob for AC capacity up to 2.0 Ton Make- Carrier/Usha/Vediocon/LG
Supply only Condenser fan blade plastic for fan Motor 1/10/ 1/16 HP for water cooler 40/150 ltr capacity.
Supply only Condenser fan blade plastic for Motor 1/32, 1/35 for water cooler 40/150 ltr capacity.
Supply only Copper filter pencil type single / Double Capillary for water cooler 40/150 ltr capacity.
Supply only Over load protector device for 150 Ltr Cap. Water Cooler .
Supply only Over load protect device for 40 Lts Cap. Water cooler .
Supply only Capacitor 6.0 MFD suitable for Air conditioner/water cooler. Make- Usha/Spicex/Tibcon/Epcos
Supply only starting Capacitor 80/100 Mfd. Make- Usha/Spicex/Tibcon/Epcos
Supply only Running capacitor 25/36 MFD for Window/Split type AC unit of Cap 1.5 Ton/2 Ton Make : Bentex/Delcon or as approved by GE.
Supply only Running capacitor 45/50 MFD for Window/Split type AC unit of Cap 1.5 Ton/2 Ton Make :- Unistar/Asian or as approved by GE.
Supply onlyStarting capacitor 100-120 MFD for Window/Split type AC unit of Cap 1.5 Ton/2 Ton Make:- Bentex/Delcon or as approved by GE.
Supply only Starting capacitor 120-150 MFD for Window/Split type AC unit of Cap 1.5 Ton/2 Ton Make :- Bentex/Delcon or as approved by GE.
Supply only Starting relay open type/Box type suitable for 150 Ltr .
Supply only Starting relay open type/Box type suitable for 40 Ltr water cooler
Supply only Starting relay 1/6 H.P. Open type with O.L.P. for Refrigerator/Deep freezer of 165 to 500 ltrs capacity.
Supply only Starting relay 1/8 H.P. open type with O.L.P. for Refrigerator/Deep freezer of 165 to 500 ltrs capacity.
Supply only Thermostat switch with Knob for Refrigerator/Deep freezer of 165 to 500 ltrs capacity.
Supply only copper filter single capillary pencil type for Refrigerator/Deep freezer of 165 to 500 ltrs capacity
Supply only Vegetable tray PVC suitable for Refrigerator of 165 to 500 ltrs capacity as per sample.
Supply only Defrost tray suitable for Refrigerator of 165 to 500 ltrs capacity as per sample
Supply only PVC ice tray flexible of existing type, make and size for Refrigerator of 165 to 500 ltrs capacity as per sample.
Supply only Refrigerator bottle shelf suitable for Refrigerator of 165 to 500 ltrs capacity Make Whirlpool/ LG/ Samsung
Supply only Waste water tray for Refrigerator of 165 to 500 ltrs capacity as per sample.
Supply only Freezer door for Refrigerator of 165 to 500 ltrs capacity as per sample.
Supply only Door Lock for Refrigerator of 165 to 500 ltrs capacity as per sample.
Supply only chiller tray for Refrigerator of 165 to 500 ltrs capacity as per sample.
Supply only ice tray for Refrigerator of 165 to 500 ltrs capacity as per sample.
Supply only Door switch for Refrigerator of 165 to 500 ltrs capacity as per sample.
Supply only Door handle suitable for Refrigerator of 165 to 500 ltrs capacity as per sample.
Supply only Refrigerator compartment Glass for Refrigerator of 165 to 500 ltrs capacity as per sample.
Supply only 900 mm long PVC connections 15 mm dia bore with PTMT nuts complete all as specified and directed.
Supply only PVC Pipe 1/2 " with Elbow plastic as per exisiting length set of three
Supply only MS Front Show grill for desert cooler as per exisitng size at site.
Supply only Plastic front Show grill for desert cooler as per existing size at site.
Supply only distributor box PVC for desert cooler.
Supply only plug top 3 pin 5A 230 volt complete all as specified and directed. Make- Cona/Indoasian/Havells.
Supply only switch piano flush type 5/6A 230 volt complete all as specified and directed. Make- IndoAsian/Legrand/crabtree/Havells
Supply only 3 pin 5/6 Amp plug top with main lead 2 mtr length for Desert cooler. Make- IndoAsian/Legrand/crabtree/Havells
Supply only float valves 15 mm dia for desert cooler/water cooler with ball complete all as specified and directed.
Supply only plug top 3 pin 15A 230 volt complete all as specified and directed .
Supply only 15 Amp 3 pin with 3 core copper PVC wire of 2 metre length
Supply only condenser fan motor 1/10, 1/16 HP of water cooler cap.150 Ltr single phase AC 220 V complete all as specified & directed.
All as per Srl No.50 here in before but for fan motor 1/32 HP for Water cooler of Capacity 40 Ltrs.
Supply only Drain hose pipe of length 05 metre for Air Conditioners/Water Coolers complete all as specified and directed.
Supply only self closing taps of cast iron galvanised, chromium plated screwed for iron pipe suitable for water coolers complete all as specified and as directed.
Supply only PVC blades for fan motor of desert cooler.
Supply only PVC insulated copper conductor cable of size 3 core, 1.0 sqmm, 1100 volt grade complete all as specified & directed
Supply only PVC insulated copper conductor cable of size 3 core, 2.5 sqmm, 1100 volt grade complete all as specified & directed.
Supply only PVC insulated copper conductor cable of size 3 core, 4.0 sqmm, 1100 volt grade complete all as specified and as directed.
Supply only PVC self adhesive electrical insulation tape roll of Nominal- 0.125mm thicknessx 1.80 cm width x 25 m length
Supply only M-Seal Fast Curing Epoxy Compound Putty Sealant Adhesive For Leakage, Bonding, Gap Filling and Repairing pack of 100 gm
Supply only Copper filter double capillary pencil type for Window/Split type AC unit of Cap 1.5 Ton/2 Ton.
Supply only Platic louvers (Front panel) for Window AC 1.5/2 Ton as per existing at site as directed.
Material & Labour for painting of desert cooler body both internally and externally by spray painting with one coat of synthetic enamel paint of approved tint and colour over a coat of red oxide primer where required after cleaning the desert cooler body throughly with the help of emery paper and dry jute cloth removing the old peep out colour layer and rust making the surface even and smooth complete all as specified and directed.
Material & Labour one coat painting with synthetic enamel paint on the body of window type AC/Split type AC outer body unit capacity 1.5/2 TR of any make and capacity with colour as per existing at site complete all as directed.
Material & Labour for repair of PCB of Indoor/Outdoor units of split AC's of capacity 1.5/2.0 ton including taking down, repair work, replacement of worn out spare parts, testing, refixing at site as per exsiting and re-testing complete all as specified and directed.
Material & Labour in replacement of angle iron stand for desert cooler/window AC made out of angle iron 40x40x5mm of required size with four legs and set of four angle for desert cooler for motor support with angle rubber, duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Material & Labour one coat of spray painting with synthetic enamel paint to refrigerator 165/310 lts cap including anticorrosive black paint on compressor, condenser coil Scratching out the existing paint with sand paper and filling up the scratches with putty complete all as specified & directed.
Cutting the rusted unserviceable base of 150/40 Ltr Capacity. water cooler body, material and labour for fabrication of New Base made of MS sheet & angle iron as per existing size and thickness incl welding of small patches as specified and directed.
Taking out the Water Cooler Tank from water cooler 150/40 ltrs capacity & repair the tank with brazing welding etc to stop the leakage of tank incl replacement of glass wool tarpaulin sheet etc. Repair to cooling coil, refixing in original position, testing and commissioning complete all as specified and directed.
Scraping & removing the existing paint from old steel surfaces of water coolers capacity 150 /40 Ltrs by rubbing, preparing the surface smooth & applying two coats of synthetic enamel paint by spray gun machine of colour as approved by Engr-in-Charge.
Material & Labour in replacement of 22 guage MS sheet of water cooler, capacity 150/40 ltrs, including nut, bolts, screws, welding if required, painting with two coats of synthetic enamel grey paint over a coat of red oxide primer complete all as specified & directed.
Supply & Fixing desert cooler pump vertical/submersible type heavy duty single phase 50 Hz, 230 volt 1340 RPM, 18/20 watt suitable for evaporative type desert cooler complete all as specified and as directed.
Supply & Fixing desert cooler motor of copper winding 500 mm sweep single phase three speed 230 volt, 180 watt, 1400 RPM including fan blades clamps and capacitor complete all as specified and as directed . Make- Khaitan/Bajaj/Crompton Greaves.
Supply & Fixing panel for desert cooler made out of 20 gauge PGI sheet with MS handle duly painted as per existing (set of 3) complete all as specified and as directed.
Supply & Fixing Wood wool pads of size- 700x700 mm set of 3 of best quality with including wire netting (chicken wire mesh) as approved by Engineer-in-charge.
Supply & Fixing hermetically sealed compressor sealed unit of deep freezer of any make and type 230 V single phase capacity 500 ltr suitable for 500 ltr deep freezer . Make : Kirloskar/Tachumsha/ Crompton
All as per Srl No.76 here in before but for 320 ltr capacity deep freezer .
All as per Srl No.76 here in before but for 205 ltr capacity deep freezer
Supply & Fixing hermetically sealed compressor unit suitable for 165 to 180 ltr Refrigerator & testing the same with two years gurantee .
All as per Srl No.79 here in before but for capacity of the refrigerator 280/ 300/310 Ltrs.
Supply & Fixing evaprotator/freezer of refrigerator, made out of aluminium suitable for 280/300/310 ltr capacity Refrigerator with freezer frame and door of existing make as per sample.
All as per Srl No.81 here in before but for capacity of the refrigerator 165 to 180 Ltrs.
Supply & Fixing hermetically sealed compressor for water cooler of capacity 40-80 Ltr complete all as specified & directed.
Supply & Fixing hermetically sealed compressor for water cooler of capacity 120-150 Ltr complete all as specified & directed.
Supply & Fixing condenser coil fins type as per existing size & patterns for Water Coolers 150 ltrs capacity complete all as specified and directed.
All as per Srl No.85 here in before but for water cooler 40 ltrs capacity.
Supply & Fixing complete Top door made out of stainless steel 20 guage sheet with handle and locking arrangement with double keys including door gasket, insulation material, PVC inner sheet of suitable thickness for 150/40 Ltr capacity water cooler as per eixsiting size and shape, welding work, nuts, bolts & washers all as directed.
Supply, laying & testing only G I Tubing 15 mm dia medium grade including all fixture & fittings as required at site complete all as specified and directed .
Supply & Fixing company manufactured sealed unit compressor for window AC of Cap 2 Ton with two years guarantee with Charging of Gas F-22/R-134A .
All as per Srl No.89 here in before but for Window Air Conditioner of Cap 1.5 Ton.
All as per Srl No.89 here in before but for spilt type Air Conditioner of Cap. 2 Ton.
All as per Srl No.89 here in before but for spilt type Air Conditioner Cap. 1.5 Ton.
Supply & Fixing air filter PVC type suitable for window type air conditioners of capacity 1 ton to 2 ton complete all as specified and as directed.
Supply & Fixing air filter PVC type filter suitable for split type air conditioner of capacity 1.5 Ton to 2.0 Ton complete all as specified and as directed.
Supply & Fixing remote control hand set for Window/ split AC of capacity 1.5/ 2.0 Ton as per existing complete all as specified and as directed
Supply & Fixing condenser fan blade for window AC of capacity 1.5/ 2.0 Ton as per existing complete all as specified and as directed Make- LG, Voltas, Carrier
Supply & Fixing condenser fan blade for split AC of capacity 1.5/ 2.0 Ton as per existing complete all as specified and as directed Make- LG, Voltas, Carrier
Supply & filling of refrigerant gas R-22/R-32 in 10 kg cylinder complete all as specified and directed
Supply & filling of refrigerant gas R-134/R-410A in 10 kg cylinder complete all as specified and directed.
Supply & fixing refrigerant copper tubing 1/4" & 1/2" all as specified and as directed.
Supply & fixing refrigerant copper tubing 3/8" & 5/8" all as specified and as directed
Supply & fixing insulation for refrigerant copper tubing 5'8", complete all as specified and as directed.
Supply & fixing insulation for refrigerant copper tubing 3'8", complete all as specified and as directed.
Supply & fixing insulation for refrigerant copper tubing 1'2", complete all as specified and as directed.
Supply & fixing insulation for refrigerant copper tubing 1'4", complete all as specified and as directed.
Supply & fixing PCB of cooling unit of split AC 1.5/ 2.0 Ton with electric accessories and sensors complete all as specified and as directed.
Supply & fixing PCB of cooling unit of window AC 1.5/ 2.0 Ton with electric accessories and sensors complete all as specified and as directed.
Supply & fixing Metal clad socket with two Pin and earth & plug top with one MCB SP 240 volt 32 Amp complete all as specified and as directed.
Supply & fixing MCB SP 240 volt 25 Amps complete all as specified and as directed.
Supply & fixing Thermocole sheet 40x20 inch and thickness 20mm for Window/Split type AC unit of Cap 1.5 Ton/2 Ton complete all as specified & directed.
Supply & Fixing Wiring kit for A.C Window/Split Type 1.5/2 Ton complete all as specified & directed.
Supply & fixing Suction and discharge valve set for Split type AC 1.5/2 TR capacity of any make as per exisiting complete all as specified & directed
Supply & fixing Reversible valve suitable for refrigerant R-22 for 1.5/ 2.0/ 3.0 TR AC including copper pipe complete all as specified & directed
Supply & fixing New condenser coil of window Type AC Cap. 1.5 Ton/2 Ton of existing make and type from any location complete all as specified & directed
All as per Srl No.114 here in before but for for split type AC 1.5/2 TR complete all as specified & directed
Supply & fixing Evaporator /Cooling coil for window type AC Cap. 1.5 Ton /2 Ton Cap of existing make and size complete all as specified & directed.
All as per Srl No.116 as here in before but for split type AC 1.5/2 TR complete all as specified & directed
Supply & fixing Indoor unit Blower motor with bush 230 V, 50 Hz suitable for Split AC Cap 1.5/2.0 Ton complete all as specified and as directed. Make- LG/Carrier/Voltas/Blue Star
Supply and fixing double shaft Blower motor 230 V, 50 Hz 1500 RPM suitable for Window AC Cap 1.5/2.0 Ton complete all as specified and as directed.Make : Crompton / Kirloskar suitable for AC of make Fedder Lloyd/ Blue star/ LG/ Carrier/ Samsung
Supply and fixing outdoor unit Cap 1.5 Ton suitable for/compatible with Split AC indoor units of capacity 1.5 ton including PCB for automatic control, with copper condensor coil, condenser fan motor, fan blades,compressor,capacitor ,relay,connector etc with all other parts of outdoor unit (complete set up) incl refrigerant R-407/22 as required at site all as specified and directed. Make-Voltas/LG/Bluestar
Supply and fixing condensing fan motor/ outdoor unit motor as per existing suitable for 1.5/2.0 Ton split type AC complete all as specified and directed.
Supply and fixing condensing fan motor as per existing suitable for 1.5/2.0 window type AC complete all as specified and directed.
Supply and fixing Indoor unit as per existing suitable for/compatible with split AC outdoor unit of capacity 1.5 Ton with evaporator coil/cooling coil, LCD display, PCB card, multi fan speeds, blower motor,auto air swing motor, filter,on-off timer ,inlet & outlet copper pipe, etc. with all other parts of indoor unit including remote control hand set complete all as specified and directed. Make-Voltas/LG/Bluestar
Supply and fixing water tank made of 20 gauge PGI sheet suitable for evaporative type desert cooler of height 20 cm as per existing shape and size all as specified and directed.
Supply & fixing Frost free thermostat for refrigerator of cap 310 litre and above as per sample as approved by Engineer-in-Charge.
Supply & fixing Timer for refrigerator of cap 310 litre and above as per sample as approved by Engineer-in-Charge.
Supply& Fixing kit for window type AC, comprising cooling/evaporator coil, condensing coil, blower motor (1.5 TR),thermostat,expansion valve and PCB plate, electrical accessories, testing complete all as specified and directed. Make: Opel/ LG/ Voltas/ Viva.
Supply & Fixing swing motor for 1.5 TR /2 TR split AC indoor unit for any type and make complete all as specified and as directed. Make: LG / Carrier / Voltas
Supply & fixing suction valve size 3/8" for 1.5/ 2 TR split AC complete all as specified and as directed.Make:- BAP / TAK Cassel
Supply and fixing discharge valve size 1/2" for 1.5/ 2 TR split AC complete all as specified and as directed.Make:- BAP / TAK Cassel
Supply and fixing door gasket suitable for 200 to 650 ltr for deep freezer doors ,water cooler and refrigerators complete as per sample all as specified and directed.
Supply and fixing condensing coil for water cooler capacity 40/80L of any make all as specified and directed.
All as per Srl No.132 here in before but for 60/120 ltr capacity.
Supply and fixing condensing coil for refrigerator 160L complete all as specified and directed.
Supply and fixing condensing coil for refrigerator 286/300 L complete all as specified and directed.
Supply and fixing gas filter flair type ¾” x ½” flare for refrigerator/deep freezer/watercooler/ACs of any capacity complete all as specified and directed.
Supply only Nitrogen gas for detection of leakage in cooling appliances complete all as specified and directed
Supply and fixing Condenser coil in replacement of old unsv condenser coil for 3 Ton outdoor unit existing as per ground complete all as specified and directed.
Supply and fixing Exhaust fan motor with fan blade used for cooling in cold storage size as per existing at ground complete all as specified and directed.
Supply and fixing Repair and Maintenance of evaporator coil used in cold storage at MH complete all as specified and directed.
Supply and fixing Expansion coil for 3 TR Split type AC/Pillar AC complete all as specified and directed.
Supply and fixing AC contactor three phase of capacity 25 Amp suitable for pillar type AC-3 TR complete all as specified and directed.Make : L&T/BCH/ABB
All as per Srl No.142 here in before but for capacity 32 Amp suitable for 5.5 TR capacity ductable type AC complete all as specified & directed .Make : L&T/BCH/ABB
All as per Srl No.142 here in before but for capacity 40 Amp suitable for LG 8.5 TR capacity ductable type AC complete all as specified & directed .Make : L&T/BCH/ABB
Supply and fixing Liquid line drier filter suitable for 8.5 ton ductale AC complete all as specified and directed. Make of drier filter: LG / Danfoss / Hitech
All as per Srl No.145 here in before but for 5.5 TR ductable type AC complete all as specified & directed. Make: Amtrex/ Danfoss/ Indofos
All as per Srl No.145 here in before but for 3 TR pillar /cassette type AC complete all as specified & directed. Make: Amtrex/ Danfoss/ Indofos
Supply and fixing of air filter set suitable for 8.5 ton ductable split type AC complete all as specified and directed. Make : LG / Danfoss / Hitech
All as per Srl No.148 here in before but for 5.5 TR ductable type AC complete all as specified & directed. Make: Amtrex/ Danfoss/ Indofos
All as per Srl No.148 here in before but for 3 TR pillar / cassette type ACcomplete all as specified & directed
Supply and fixing Low / high pressure switch for 8.5 ton ductable split type AC complete all as specified and as directed. Make : LG / Danfoss / Hitech
All as per Srl No.151 here in before but for 5.5 TR/3 TR ductable type AC complete all as specified & directed. Make: Amtrex/ Danfoss/ Indofos
Supply and fixing Hermetically sealed three phase scroll compressor of capacity 3 ton complete all as specified and directed. Make : LG/ Danfoss/ Sanyo/ Tecumseh/Kirloskar/ Comipro/Copeland
All as per Srl No.153 here in before for but hermetically sealed three phase scroll compressor suitable for 8.5 TR suitalbe for 8.5 TR ductable AC. Make : LG / Kirloskar / Tecumseh/Danfoss/Comipro/Copeland
All as per Srl No.153 here in before but for hermetically sealed three phase scroll compressor of capacity 5.5 TR suitalbe for 5.5 TR ductable AC. Make : LG / Kirloskar / Tecumseh/Danfoss/Comipro/Copeland
Taking down voltage stabilizer upto 5 KVA capacity of any make 220 volt for carrying out checking, overhauling including supply and replacement of the under mentioned defective parts of identical size and capacity complete with testing on load complete all as specified and as directed. Volt meter 0 to 300 volt
Relay transformer 12 volt complete all as specified and directed.
IC 240 volt 25 Amps complete all as specified and directed.
Rewinding of main transformer with existing size gauge of super enamelled copper winding wire and insulating materials complete all as specified and directed.
Operating switch push/knob type of voltage stabilizer complete all as specified & directed
Indicating lamp of voltage stabilizercomplete all as specified & directed
Taking out worn out existing 6mm/3mm thick ply wood and S&F 6.0 mm thick plywood for making air tight of desert coolers/air conditioners complete all as specified and directed.
Marerial and labour for shifting of AC's any type/capacity from any height & location and refix the same on another location after making necessary cutting on wall/roof/window/glass/grills as per requirement of users, complete all as specified and directed. (Note:- Necessary insulation for copper tubing, gas filling, ply work shall be measured and paid seperately under respective item)
Taking out of defective wiring of unit, PCB, visual eye plates, unserviceable parts control parts and fixing the new wiring, PCB, control parts in place of damaged items of Mechanical Laundary including matching the existing system complete all as specified and directed
Periodical maintenance and Servicing of RO Plant four times in year including replacement of all three types of defective filter and replacement of defective parts incl pump by authorized RO dealer as per site requirement complete all as specified and directed.
Material & Labour for sub main wiring with two runs of single core, PVC insulated, unsheathed ,multi standard copper conductor cable of size 4 Sqmm, 1100 volts grade and one run of 2.5 Sqmm PVC insulated earth continuity copper conductor cable drawn through and inculding suitable size of PVC concealed conduit with all necesary accessories such as bends, tees, junctions boxes, elbows etc complete with all in coming and out going cable connections complete all as specified and directed. (Note : Two runs of 4 Sqmm cable, one run of 2.5 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one unit length).
Disconnecting electric connection from defective blower motor and taking out from window type/ split AC outdoor unit capacity 1.5/2 TR of existing make and transporting to store yard of Refg AC Section, then to be transported to contractors workshop after getting the gate pass from Engineer-in-Charge. Dismantling the burnt winding & rewinding of 1/6 to 1/8 HP double shaft blower motor with the existing size of super enemelled copper winding wire including insulation, varnishing, greasing, testing complete and transporting back to the location from where it was disconnected and refixing the same and testing complete all as specified and directed.
Taking out of defective wiring of indoor/ outdoor unit, PCB, visual eye damp plates, unserviceable cordless electronic remote control and fixing the new wiring, cordless electronic remote control, PCB, visual eye damp plate in place of damaged items of split AC of capacity 1.5 TR/ 2TR including matching the existing system complete all as specified and directed. Make of AC & remote: Carrier/ LG/ Hi series/ Samsung/Voltas
Disconnecting electric connection from defective blower motor and taking out from desert cooler of existing make and transporting to store yard of Refg AC Section, then to be transported to contractors workshop after getting the gate pass from Engineer-in-Charge. Dismantling the burnt winding & rewinding of 180 watt single phase motor with the existing size of super enemelled copper winding wire including insulation, varnishing, greasing, testing complete and transporting back to the location from where it was disconnected and refixing the same and testing complete all as specified and as directed.
Note:- Amount of credit of Rs. 246617.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in PDFf form which will be deducted offline while acceptance of tender.
kapil enterprises
R. P. Suppliers and Construction Co.
Saurav Enterprises
u and v engineers and consultants
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .