Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹16.7 L+₹1.8 L (11.9%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹17.8 L+₹2.9 L (19.2%)Rejected-Finance WZ 1391 31 B NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Being not lowest | |
| 4 | Not Admitted-Finance 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | - | Not Admitted-Finance Price Bid not complied | |
| 5 | Not Admitted-Finance | - | Not Admitted-Finance Price Bid not complied |
Tender Value
Refer Docs
EMD Value
₹43,500
Closing Date
22 Dec 2020, 6:00 pmClosed
Lt Col Sidhartha Singhal
GE (P) Dappar
Outsourcing of services for manning and operation and for attending electrical breakdowns of 11 KV Main Receiving Station at Mil Stn Dappar under GE (P) Dappar
2020_MES_394115_1
GE (P) DPR-27/2020-21
Open Tender
Miscellaneous Services
Supply
330 days
GE (P) Dappar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (P) Dappar
₹43,500
Yes
5 Jan 2021
10 Nov 2020
24 Dec 2020
10 Nov 2020
22 Dec 2020
8 Dec 2020
10 Nov 2020 - 8 Dec 2020
Amount
Manning and operation of power house comprising of under mentioned equipment at 11KV receiving Stn (03 shifts) in addition to attend and rectify electrical berakdowns by operation of GODs, binding of DO fuse units on 02/04 pole structure, testing of Transformers, trimming of tree branches, operation of MCCBs, cutting and refixing of burnt out cables, etc. located at various locations of 33 FAD Dappar as directed by Engr-in-Charge including Sunday and holiday complete by a technically qualified one Skilled electrician / (SBA) in each shift round the clock including maintaining all records as directed - (i)11 KV HT VCBs - 10 Nos., (ii) Step down transformer 11 / 0.433 KV of various ratings - 17 Nos. (iii) DC battery bank - 24 Volt, 70 AH - 01 No., (iv) LT automatic power factor correction panels of various capacities - 17 Nos. (vi) LT Panels floor mounted comprising of MCCBs of various ratings installed in Tech and Adm areas, etc.
as per item No 1.00 above but, EPF as notified by the Govt (as per notes given in this schedule)
as per item No 1.00 above but, EDLI as notified by the Govt / as applicable (as per notes given in this schedule)
as per item No 1.00 above but, Administration Charges on EPF (Employer contribution) as notified by the Govt (as per notes given in this schedule)
as per item No 1.00 above but, ESIC as notified by the Govt / as applicable (as per notes given in this schedule)
as per item No 1.00 above but, Bonus as notified by the Govt (as per notes given in this schedule)
as per item No 1.00 above but, Overhead and Profit (as per notes given in this schedule)
as per item No 1.00 above but, GST as notified by the Govt (as per notes given in this schedule)
as per item No 1.00 above but, LWC as notified by the Govt (as per notes given in this schedule)
All-as per item No 1 above but with 01 Unskilled Electrician inclusive of attending Day to Day internal electrical complaints/eletrical breakdowns 03 (Three) shifts including Sundays and holidays complete by a helper in each shift round the clock all as directed by Engr-in -charge.
as per item No 2.00 above but, EPF as notified by the Govt (as per notes given in this schedule)
as per item No 2.00 above but, EDLI as notified by the Govt / as applicable (as per notes given in this schedule)
as per item No 2.00 above but, Administration Charges on EPF (Employer contribution) as notified by the Govt (as per notes given in this schedule)
as per item No 2.00 above but, ESIC as notified by the Govt / as applicable (as per notes given in this schedule)
as per item No 2.00 above but, Bonus as notified by the Govt (as per notes given in this schedule)
as per item No 2.00 above but, Overhead and Profit (as per notes given in this schedule)
as per item No 2.00 above but, GST as notified by the Govt (as per notes given in this schedule)
as per item No 2.00 above but, LWC as notified by the Govt (as per notes given in this schedule)
NOTES - FINANCIAL EVALUATION CRITERIA :- The provision of statutory laws relating to Minimum wages as per Code of wages 2019 including social security such as EPF and ESI shall be strictly adhered by the contractor and the quoted rate shall deemed to include these factors. Following rates of minimum wages, statutory provision and contractor profit & overhead charges shall be deemed to have been considered during financial evaluation :- (a) Minimum wages :- As per as latest notification issued by Government of India/State Government/Local body whichever is higher as on bid submission end date. (b) ESI (Insurance cover) @ 3.25% on minimum wage. In case monthly (26 days) minimum wage are exceeding Rupees twenty one thousand (Rs 21,000/-), ESI shall be exempted. (c) EPF (Employees provident fund) @ 12.00% on minimum wage. In case monthly (26 days) minimum wage are exceeding Rupees fifteen thousand (Rs 15,000/-) EPF shall be calculated for amount Rupees fifteen thousand (Rs 15,000/-) only. (d) EDLI @ 0.5% on total amount. (e) Administration Charges @ 0.5% on total amount. (f) Minimum Bonus applicable is @ 8.33%. (g) Labour cess @ 1% on total amount. (h) GST applicable is @ 18% on total amount. (j) The bidder shall have to be consider their profit and overhead charge on above provision. In case bidder considers Nil profit and overhead charge, the bidder shall be treated as a unresponsive and his offer shall be consider as a non bonafide bid. (k) Any quoted rate against the Sch Item as detailed above which corresponds to/works out to lower than the correspondening prevailing minimum rates of wages/subscription/contribution towards EPF, ESIC, Bonus and LWC shall be treated as non-bonafide and such bid shall not be considered for acceptance. The prevailing rate/wage/contribution shall be as applicable on the bid submission end date. If the Contractor's Profit quoted is equal to zero, the bid will be treated as non-bonafide.
Work done amount will only be paid to the Contractor only after he/she will submit a valid and authentic document in support of having paid the requisite amount of bonus to the workmen i.e. proof of payment. Monthly e banking statement stating payment done to the employees shall be furnished by contractor to the Engineer-in-Charge and the same shall be kept in record duly verified by Engineer-in-Charge alongwith monthly e-banking statement of employed employee EPF account stating monthly deposit of EPF & ESI by the contractor.
Operator shall be well qualified and should be adequately experienced as under :- (a). SKILLED Tradesman - Diploma Holder with 3 years experience or ITI with 5 years experience. (b). SEMI SKILLED Tradesman - class 12th pass with 5 years experience. (c). Helper - UNSKILLED workmen shall have experience of minimum 3 years in the relevant trade.
In case the operator is found without proper uniform/dress as mentioned earlier, a penalty of Rs 100/- per day per operator shall be charged.
Payment to the worker shall be made on or before 07th day of every month, as per attendance register.
The contractor will submit the employee details as specified in PS of his Contract to the Engineer-in-Charge regarding each person to be employed by him under this contract within seven days from the date of commencement failing which the recovery of Rs 100/- per person per day shall be made from the contractor upto maximum of 15 days. After that the worker shall not be allowed to attend the installations and the contractor shall replace the person immediately otherwise further period shall be treated as absent and recovery shall be made as per P.S clause 71A of this Contract.
If the Accepting Officer finds the labours employed by the Contractor as not competent for the job, the same will be intimated to the Contractor on the 15th day of the same month. Contractor has to replace the respective labour before or on the last day of the month otherwise further period shall be treated as absent and recovery shall be made as per P.S clause 71A of this Contract.
The installations shall be manned and operated on all days as indicated in Schedule ‘A’. In case, the operator of the contractor found missing and / or the installation is found running unattended, during the check of installation by any officer, a penalty of Rs 420/- per shift per operator and or Rs 55/- per hour per operator per installation shall be make from the contractor. In addition to above the manning charges of that shift/period shall also not be paid to the contractor. No claim whatsoever shall be entertained from the contractor on his account.
All tools and machinery required for routine works, preventive maintenance etc. (for example such as pliers, cutter, screw drivers, spanner set, blower, drill machine, crimping tool, megger, earth tester, pipe wrench, tripod, safety equipment‟s etc.) shall be provided by the contractor cost of which is deemed to be included in the quoted rate.
The staff will ensure wearing respective work masks, safety gloves and belts as and when required cost of which is deemed to be included in the quoted rate.
Agency should provide Police Verification & Character Certificate of the manpower. The clearance of the local police with regards the antecedents of the persons deployed by it will be obtained by the agency before deployment of the personnel.
Any extra labour of any nature if required, at any time for attending any type of minor or major repair/break down shall be deployed by the contractor at his own cost for which nothing extra shall be payable.
Cost of conveyance for carrying and for filling of diesel from MES Yard to the installation for running of DG Sets is deemed to be included in the quoted rate.
Log sheets shall be prepared and kept on record in a binded folder covered with leather clad hard cover, all pages serially machine numbered cost of which is deemed to be included in the quoted rate.
After the approval of Operator the Contractor is required to submit at his own cost the cloth bound IDENTITY CARD duly affixed with a Passport size Photograph of Operators and one spare Photograph (both attested by the Contractor) to the Engineer-in-Charge, for his Countersignature. One copy of the Photograph shall be retained by the Department. Any Operator not in possession of requisite IDENTITY CARD shall not be allowed to handle the Installation.
Weekly "off " as per Lobour act to be given to the Operator& reliever to be Provided by the Contractor at no Extra Cost.
Supply and fix cable jointing kit for 1100 V grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size upto 25 to 50 sqmm, core outdoor type and taking down fault complete all as specified and directed by Engr-in-Charge. Make : Denson/M Seal/Birla
Supply and fix cable jointing kit for 1100 V grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size upto 50 to 95sqmm, core outdoor type and taking down fault complete all as specified and directed by Engr-in-Charge. Make : Denson/M Seal/Birla
Supply and fix cable jointing kit for 1100 V grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size upto120 to 150 sqmm, core outdoor type and taking down fault complete all as specified and directed by Engr-in-Charge. Make : Denson/M Seal/Birla
M&L in repairs Heat shrinkable straight through cable jointing kit suitable for earthed 3 core 95/120 sqmm HT 11 kV XLPE aluminium conductor cable incld. disconnecting concerned cable, cutting out burnt/damaged jointing kit, jointing new kit inld. testing and commissioning of the complete cable to the complete satisfaction of Engr-in-Charge all as specified and directed. Make:- Raychem/ XICON/ M-Seal/Denson. NOTE- (a). The quoted rate is deemed to be inclusive of cost of saddling or clamping of cable all as directed by Engr-in-Charge. (b). Contractor has to arrange proper electrical shutdown after informing to depratment concerned. (c). Cost of connected excavation, soil removal, returning filling in, sand cusshioning and cable covers will be measured and paid in the respective items of the Schedule.
M&L in repairs Heat shrinkable outdoor type end termination cable jointing kit suitable for earthed 3 core 95/120 sqmm HT 11KV XLPE aluminium conductor cable incld. disconnecting concerned cable, cutting out burnt/damaged jointing kit, jointing new kit inld. testing and commissioning of the complete cable to the complete satisfaction of Engr-in-Charge all as specified and directed. Make:- Raychem/M-Seal/Denson. NOTE- a. The quoted rate is deemed to be inclusive of cost of saddling or clamping of cable all as directed by Engr-in-Charge. b. Contractor has to arrange proper electrical shutdown after informing to depratment concerned.
Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, S&F MCCB FP, 36kA, 400 AMPS with Thermal - Magnetic Release Type Ics = 100% Icu, Adjustable Over Load setting: 0.4 -1.0 x In, Adjustable short circuit for each phase from 1.5 - 8 x In, Make - L&T, Cat No. - CM98401OOROOG including spreader terminals (Make-L&T, Cat No.-ST98066OOOO). NOTE - Quoted rate is deemed to be inclusive of minor jobs and minor spares required for fitment of MCCB in the existing panel.
Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, S&F MCCB TP, 25kA, 250 AMPS with Thermal - Magnetic Release Type, Ics = 100% Icu, Adjustable Over Load setting: 0.4 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In, Make - L&T, Cat No. -CM90642OOPO including spreader terminals (Make-L&T, Cat No.-ST98066OOOO).
Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, S&F MCCB TP, 25 kA, 200 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In, Make - L&T, Cat No. - CM90642OONO including spreader terminals (Make-L&T, Cat No.-ST98066OOOO).
Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, S&F MCCB FP, 25 kA, 125 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In, Make - L&T, Cat No. - CM9064200L0 Spreader terminals (Make-L&T, Cat No.-ST98066OOOO).
Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, S&F MCCB FP, 25 kA,100 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In, Make - L&T, Cat No. -CM9172000k00G including spreader terminals (Make-L&T, Cat No.-ST98066OOOO).
Supply only fuse wire (Tin & Copper) 16/18/20 SWG complete all as specified and as directed by Engr-in-Charge.
Taking down unserviceable ACSR conductor and supply and fixing aluminium conductor steel reinforced any type complete all as specified and as directed by Engr-in-Charge.
Restringing and Fixing ACSR Conductor reinforced of any size to proper sag incl binding on insulator all as specified and as directed by Engr-in-Charge
Cutting & trimming of tree branches any girth and size around overhead lines to a clear distance 1.5 mtr both sides of overhead line with in a 25 to 40 mtrs span gap of HT/LT lines including clearing the site all as specified and directed by the Engr-in-Charge.
M&L for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending, cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide zinc chrome primer including removing old unserviceable rusted ones complete all as directed by Engineer-in-Charge
M&L for stay assembly complete with accessories as shown in electric plate No.I including loop type insulator, stay clamps etc complete all as specified & directed with diameter of stay 20 mm of stay rod complete all as specified & directed. Note: - Loop type insulator, PCC foundation, Exc & earth work & GI stay strand will be measured and paid seperately under relevent items of Sch 'A'
Dismantling of unserviceable insulator any type and any size.
M&L for disc insulator porcelain vitreous brown 145 mm height & 225 mm dia ball and socket type two in series assembly with cast aluminium 4 U bolt tension hardware and tension clamps for conductors working pressure HT 11 kV complete all as specified and directed.
S&F Male contact (gunmetal) suitable for vertical operating type GOD 11 kV grade, 200 Amps rating in position as in replacement including testing and commissioning to the complete satisfaction of Engr-in-Charge.
.- ditto- as per srl item No. 38 but Female gunmetal contact.
.- ditto- as per srl item No. 38 but Tinned copper flexible jumper.
M&L for fixed type top contact for DO fuse units 11 kV in replacement complete all as specified and directed.
M&L for fixed type bottom contact for DO fuse units 11 kV in replacement complete all as specified and directed.
Fixing only LED LUMINARIE, pressure die cast aluminum housing, 25/45/60/70 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete all as directed and specified by Engr-in-charge.NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate.
Disconnecting & taking out old unserviceable LT cable of size 120 sq mm 3.5 core.
Disconnecting & Taking out old unserviceable LT cableof size 70 sq mm 3.5 core
Disconnecting & Taking out old unserviceable LT cable of size 50 sq mm 3.5 core
Disconnecting & Taking out old unserviceable LT cable of size 35 sq mm 3.5 core
Disconnecting & Taking out old unserviceable LT cable of size 25 sq mm 4 core
Disconnecting & Taking out old unserviceable LT cable of size 16 sq mm 4 core
Disconnecting & Taking out old unserviceable LT cable of size 10 sq mm 2 core
Re -laying , jointing, connecting, testing & commissioning UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured electric power cable (heavy duty 1100 volts grade with standard aluminium conductor of cross sectional area 120 sqmm x 3.5 core all as specified and directed by Engr-in-Charge. NOTE - (a). The quoted rate is deemed to be inclusive of arranging respective shutdown, disconnection of cables, commissioning of feeder after the completion of job and inclusive of any minor spares and jobs required for the completion of the job. (c). The cost of excavation, returning, filling, removal and PCC cable covers will be measured and paid under relevant items of this schedule.
Description all as per ser item No 51 here-in-before but size of LT under ground cable 70 sqmm 3.5 core.
Description all as per ser item No 51 here-in-before but size of LT under ground cable 50 sqmm 3.5 core.
Description all as per ser item No 51 here-in-before but size of LT under ground cable 35 sqmm 3.5 core.
Description all as per ser item No 51 here-in-before but size of LT under ground cable 25 sqmm 4 core.
Description all as per ser item No 51 here-in-before but size of LT under ground cable 16 sqmm 4 core.
Description all as per ser item No 51 here-in-before but size of LT under ground cable 10 sqmm 2 core.
Excavation in trenches in soft/loose/hard soil n exc 1.5 m wide and not exc 1.5 m in depth and getting out including forming bottom to required level or slope for laying pipes / laying of cable complete all as specified and as directed by Engineer-in-Charge.
Returning filling in soft / loose soil in trenches including spreading, leveling and well ramming in 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge.
Removal of surplus soil to a distance n exc in 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
Material and labour sand cushioning (dry sand) to underground cable for cable protection 23 cm thick in two layers (8 cm thick before laying of cables and 15 cm thick after laying the cable and punning down the sand to 18 cm thickness.). Complete all as specified and as directed by Engineer-in-Charge. (Note:- Only punned thickness 18 cm of sand shall be measured for payment purposes).
Re- Laying precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm.
S&F in repairs power capacitor duty contactor 3 phase with auxilary switch block 415 volts suitable for 10 kVAR capacitor complete with connected switch gear/ components in various APFC panels of L&T make Type MO C10 Cat Part No. CS96156 or equivalent in Makes as per PS of this CA all as specified and directed by Engr-in-Charge.
S&F in repairs power capacitor duty contactor 3 phase with auxilary switch block 415 volts suitable for 15 kVAR capacitor complete with connected switch gear/ components in various APFC panels of L&T make Type MO C15 Cat Part No. CS90019 or equivalent in Makes as per PS of this CA all as specified and directed by Engr-in-Charge.
S&F in repairs power capacitor duty contactor 3 phase with auxilary switch block 415 volts and Spreader Link Kit suitable for 25 kVAR capacitor complete with connected switch gear/ components in various APFC panels of L&T make Type MO C25 Cat Part No. CS96322 or equivalent in Makes as per PS of this CA all as specified and directed by Engr-in-Charge.
S&F in repairs NO element complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
S&F in repairs NC element complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
S&F in repairs Illuminated push button- RED complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
S&F in repairs Illuminated push button- GREEN complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
S&F in repairs 1.1 KV current transformer of ratio 150/5 complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
S&F in repairs 1.5 Sqmm multistranded copper FRLSH wire for control circuit complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
S&F in repairs 6 sqmm multistranded FRLSH copper flexible cable complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
S&F in repairs 1.5 sqmm pin type lugs complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
S&F in repairs 6 sqmm pin/fork/round type lugsr complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
S&F in repairs 6-32 A SP MCB, 10 kA 'C' series, 240 V AC, 50 Hzcomplete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
S&F in repairs 32 A TP MCB, 10 kA 'C' series, 415 V AC, 50 Hz complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
S&F in repairs 63A TPN MCB, 10 kA 'C' series, 415 V AC, 50 Hz complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
S&F in repairs 2 way slector adaptor 25 Amps complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
M/S Sonu Traders
G M CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .