| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.2 LAccepted-AOC PO BANARHAT DIST JALPAIGURI W B PIN 735202 | BANARHAT | JALPAIGURI | WEST BENGAL | 735202 | ₹47.2 L Quoted ₹48.8 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹49.0 L+₹21,365.55 (0.44%)Rejected-Finance P O BINNAGURI 735203 DISTT JALPAIGURI W B | JALPAIGURI | WEST BENGAL | 735203 | ₹49.0 L+₹21,365.55 (0.44%) | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 3 | L3₹50.2 L+₹1.4 L (2.85%)Rejected-Finance | ₹50.2 L+₹1.4 L (2.85%) | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 4 | Rejected-Technical | - | - | Rejected-Technical DOCUMENTS ARE NOT FOUND IN ORDER |
| 5 | Rejected-Technical DURGA NAGAR CHECK POST PO ETHELBARI DIST ALIPURDUAR PIN 735204 WB | ALIPURDUAR | WEST BENGAL | 735204 | - | - | Rejected-Technical DOCUMENTS ARE NOT FOUND IN ORDER |
| Sl No | Description | Qty | Unit | BBKundu L2 | SHRI SANJAY KUMAR GUPTA L1 | S.N. GHOSH AND CO. L3 |
|---|---|---|---|---|---|---|
| 1.00 | M&L for periodical repair, maintenance & overhauling of 11 KV HT VCB 630 Amp including opening, checking, cleaning with CTC, cleaning wiping of insulating component, incl primary & secondary current enjection test , spouts, busbars, supports, CT, PT, cleaning contact tips, cover the expossed portion of busbar with HT tape & heat shrinkable sleeves, spout insulators for visible crack, tightness of fasterners holding moving contacts, check & correct the buffer gap adjustment & mechanism settings, meters. Testing and calibration of all relays fitted in control panels from technician minimume 5 years experiance , such as earth fault relays, over current relays fitted in HT 11 KV panels for its corrections & setting with main control panel relays individual VCB shall be tripped prior to main panel. Testing, cleaning & overhauling of complete operating mechanism for smooth functioning, checking of control panel wiring for operation & protection for tripping & closing & rectifying the defects all equipments including Deoxidizing of all electrical contacts replacement unserviceable wiring with ferrule & lugs, reassembling & testing of complete VCB, complete all as specified and directed by Engineer-in-charge. | 1 | EACH JOB | 14,999 ₹14,999 | 16,000 ₹16,000 | 14,500 ₹14,500 Lowest |
| 2.00 | M&L for periodical repair, maintenance & overhauling of 11 KV compect sub station 400 KVA including opening, checking, cleaning VCB,Transformer , cleaning wiping of insulating component, incl primary & secondary current enjection test , spouts, busbars, supports, CT, PT, cleaning contact tips, cover the expossed portion of busbar with HT tape & heat shrinkable sleeves, spout insulators for visible crack, tightness of fasterners holding moving contacts, check & correct the buffer gap adjustment & mechanism settings, meters. Testing and calibration of all relays fitted in control panels from technician minimume 5 years experiance, such as earth fault relays, over current relays fitted in panels for its corrections & setting with main control panel relays individual VCB shall be tripped prior to main panel. Testing, cleaning & overhauling of complete operating mechanism for smooth functioning, checking of control panel wiring for operation & protection for tripping & closing & rectifying the defects all equipments including Deoxidizing of all electrical contacts replacement unserviceable wiring with ferrule & lugs, reassembling & testing, complete all as specified and directed by Engineer-in-charge. | 2 | EACH JOB | 17,999 ₹35,998 | 19,500 ₹39,000 | 16,000 ₹32,000 Lowest |
| 3.00 | M & L for complete servicing and calibration of HT 11 KV RMU relays and tripping mechanism for regulating the fault flow (over current,Earth fault,differential) in sequence from down stream 11 KV distribution VCB's to SF-6 Breaker at switch room of receiving station complete and getting tested and certified by the authorised testing agency/maufacturing agency for accuracy for efficient functioning and servicing and cleaning to VCB trolleys 11 KV,3 pole,630 Amps including repairs to manual charging system of vaccum circuit breaker by servicing the charging mechanism(T1) and Operating mechanism (T2) and electrical connections, complete all as specified and directed by Engineer-in-charge.
Note:- i) Required spare parts for replacement will be measured and paid under relivant item as supply only under this schedule.
(ii) Cost of Labour for replacement is demed to be included under this item. | 1 | EACH JOB | 15,999 ₹15,999 | 17,990 ₹17,990 | 14,000 ₹14,000 Lowest |
| 4.00 | Supply Only Trip Catch Assembly, complete all as specified and directed by Engineer-in-charge. | 2 | EACH | 3,499 ₹6,998 Lowest | 4,000 ₹8,000 | 4,000 ₹8,000 |
| 5.00 | Supply Only Trip Shaft Assembly, complete all as specified and directed by Engineer-in-charge. | 2 | EACH | 2,099 ₹4,198 | 2,400 ₹4,800 | 1,500 ₹3,000 Lowest |
| 6.00 | Supply Only Closing Shaft Assembly, complete all as specified and directed by Engineer-in-charge. | 2 | EACH | 2,099 ₹4,198 Lowest | 2,400 ₹4,800 | 2,500 ₹5,000 |
| 7.00 | Supply Only Closing Coil Assembly, DC 110 Voltage, complete all as specified and directed by Engineer-in-charge. | 2 | EACH | 3,099 ₹6,198 Lowest | 3,750 ₹7,500 | 4,500 ₹9,000 |
| 8.00 | Supply Only Tripping Coil Assemblyy, DC 110 Voltage, complete all as specified and directed by Engineer-in-charge. | 2 | EACH | 3,299 ₹6,598 Lowest | 3,750 ₹7,500 | 4,500 ₹9,000 |
| 9.00 | Supply Only Auxiliary switch 6 NO/6NC, complete all as specified and directed by Engineer-in-charge. | 2 | EACH | 3,099 ₹6,198 Lowest | 3,400 ₹6,800 | 4,500 ₹9,000 |
| 10.00 | Supply Only Indicating VCB Lamps (RYB) LED type of Shape & Size as per existing, complete all as specified and directed by Engineer-in-charge. | 2 | EACH SET OF THREE | 199 ₹398 Lowest | 210 ₹420 | 200 ₹400 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
3 Jan 2026, 6:00 pmClosed
CWE BINNAGURI
HQ CWE BINNAGURI, BINNAGURI CANTT, JALPAIGURI, WEST BENGAL, PIN-735232
REPAIR/REPLACEMENT AND MAINTENANCE TO TRANSFORMER, VCB PANEL, RMU, HT/LT UNDERGROUND CABLE, OVERHEAD LINES, LT PANEL BOARD, FEEDER PILLAR BOXES, EARTHING AND OTHER CONNECTED WORKS AT BINNAGURI, COOCH BEHAR AND HASIMARA MILITARY STATION UNDER GE SOUTH
2025_MES_744262_1
8289/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (S) BINNAGURI
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (S) BINNAGURI
₹1 L
Yes
3 Mar 2026
13 Dec 2025
5 Jan 2026
13 Dec 2025
3 Jan 2026
27 Dec 2025
M&L for Onload filtration and dehydration of transformer oil by on load filtration plant machine to achive minimum 40 KV dielectric strength complete and testing the dielectric strength and contents of acid before and after filtration at different locations of 11 KV / 440 V installations, complete all as specified and directed by Engineer-in-charge.
M&L for Filling only new transformer oil for topping up or replacement oil transformers 11 KV / 440 V at different locations during the process of filtration, complete all as specified and directed by Engineer-in-charge.
M & L for silica gel in breathers of transformers of various capacities including taking down of unserviceable silica gel, complete all as specified and directed by Engineer-in-charge.
M&L for Structural steel work as the Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat one under coat and one finishing coat of synthetic enamelled paint including taking down old unserviceable, complete all as specified and directed by Engineer-in-charge.
M&L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 metres long) including dismantling of old unserviceable one, complete all as specified and directed by Engineer-in-charge. Note: Excavating & PCC work shall be measured and paid separtley under relevnt item of this schedule.
M & L for PCC(1:3:6) type C-2(using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete of above ground level of steel pole, complete all as specified and directed by Engineer-in-charge.
M & L for PCC(1:2:4) type C-2(using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete for coping of above ground level of steel pole, complete all as specified and directed by Engineer-in-charge.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 including, surface even & smooth without using extra cement, complete all as specified and as directed by Engineer-in-charge.
M&L for taking out old unserviceable cable of any size from trenches , GI pipe protection, with and including separating serviceable bricks & set aside and removing un-serviceable bricks from site, complete all as specified and as directed by Engineer-in-charge. Note :- (i) The Excavation and earth work shall be measured and paid separately under relevant item of this Sch).
Supply, laying & testing of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100Volt grade on walls with fixing accessories of size 10 Sqmm 2 Core cable, complete all as specified and directed by Engineer-in-charge. Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately.
Supply, laying & testing of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100Volt grade on walls with fixing accessories of size 16 Sqmm 4 Core cable, complete all as specified and directed by Engineer-in-charge. Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately.
Supply, laying & testing of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100Volt grade on walls with fixing accessories of size 35 Sqmm 3.5 Core cable, complete all as specified and directed by Engineer-in-charge. Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately.
Supply, laying & testing of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100Volt grade on walls with fixing accessories of size 50 Sqmm 3.5 Core cable, complete all as specified and directed by Engineer-in-charge. Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately.
Supply, laying & testing of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100Volt grade on walls with fixing accessories of size 70 Sqmm 3.5 Core cable, complete all as specified and directed by Engineer-in-charge. Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately.
Supply, laying & testing of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100Volt grade on walls with fixing accessories of size 95 Sqmm 3.5 Core cable, complete all as specified and directed by Engineer-in-charge. Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately.
Supply, laying & testing of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100Volt grade on walls with fixing accessories of size 120 Sqmm 3.5 Core cable, complete all as specified and directed by Engineer-in-charge. Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately.
Cutting unaxious green growth and wild grass by manual labour or by machine at Electrical Installation Permises around pole, around panel board along boundaries fencing, removing runnish material from work site and depositing where directed not exc. 100 meter from the starting point, complete all as specified and directed by Engineer-in-charge. Note : The item shall be operated every 1.5 months interval period of the Contract period and measurement will be taken every time independently for payment.
Material and labor for test Point Terminal Block, made of Gun Metal or Phosphorous Bronze, size 75 x 75 x 25 mm. The block shall be drilled and screwed, including three (3) Nos {8 mm dia. x 25 mm} hex-head screws. It must feature rectangular openings for the entry of the down earth strip and include all necessary fixing screws and bolts for wall mounting including taking down old unserviceable complete all as specified and as directed by Engineer-in-charge.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion including taking down old unserviceable one, complete all as specified and as directed by Engineer-in-charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil, complete all as specified and directed by Engineer-in-charge.
Excavation in trenches n.exc 1.5m wide and exc 1.5 m but n exc 3.0 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as per speci
Removing excavated materials to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point, complete all as specified and directed by Engineer-in-charge.
S&F in repair of Danger notice plate of 1.6 mm thick mild steel sheet letters, figures and conventional skull and bones in single red colour and fixed with M.S clamps, bolts and nuts of approved size, for HT pole, of size 25x20cm, complete all as specified and directed by Engineer-in-charge.
Dismantling and repairs of defective GODswitch, current rating upto 200/400 Amps,11000 Volts grade,including merging of insulators and operating mechanism and replacement of Male and Female contact,handle,arching horn and all rusted GI Nuts,Bolts and washers for proper connection of ACSR conductord/Cables and necessary Greasing etc. to make 100% serviceability and proper functioning of GOD switch including taking down of unserviceable insulators of any type and replace with New Insulators (Insulators shall measured and paid separately) and testing after repair, complete all as specified and directed by Engineer-in-charge.
S&F in repair of 11KV Dropout Fuse unit D type Porcelain, complete all as specified and directed by Engineer-in-charge.
Supply, laying & testing of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100Volt grade on walls with fixing accessories of size 10 Sqmm 4 Core cable, complete all as specified and directed by Engineer-in-charge. Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately.
Supply, laying & testing of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100Volt grade on walls with fixing accessories of size 185 Sqmm 3.5 Core cable, complete all as specified and directed by Engineer-in-charge. Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately.
EACH SET OF THREE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
8289TenderDocuments.pdf
Tender Documents • 0.95 MB
BOQ_833387.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .