Office of the Assisstant Executive Engineer PWD Electrical Subdivision Thalassery
GENERAL-Town beautification - Budget work 2019-20 We Park under Muzhappilangad ROB in Dharmadam LAC in Kannur District-Providing Decorative Lights General Electrical Work
2026_PWD_862553_2
PWD/BLDG/TR/186/2026_6_1_1/1
Open Tender
Electrical Works
Item Rate
90 days
KANNUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,850
₹20,925
19 Sept 2026
19 Sept 2026
1 Oct 2026
19 Sept 2026
28 Sept 2026
19 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Footpath Lighting | |||||
| 1.001 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. | 5 | cum | - | - |
| 1.002 | 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). | 2 | cum | - | - |
| 1.003 | OD269070/2025-2026:Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using tor steel as required. | 50 | kg | - | - |
| 1.004 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels | 2 | sqm | - | - |
| 1.005 | OD269068/2025-2026:SITC of LED Decorative Classic luminaire of system wattage 50W, with minimum
dimension 315mm width and 545mm height, BIS certified with a body
and frame of high pressure die cast aluminium, a frosted PMMA protector (IK06)
fixed on tothe optical unit
, separate optical and control gear compartment accessed by opening four
screws at the top of the luminaire, a vent pressure equalization unit and pre-cabled as
required. The luminaire shall have ingress protection of IP66. Highly efficient
temperature
resistant lenses for light distribution with several optical options providing excellent
photometry to optimally cater to different applications. Overall system efficiency of
120lm/W at correlated colour temperature (CCT) 3000K, colour rendering index
(CRI) >70
and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac,
Power
Factor > 0.95, with BIS certified potted driver having internal surge protection of 4
kV and an additional surge protection device (SPD) of 10 kV . ( KESSLEC RILA 50W WW)/ eqvt K lite/ eqvt ) | 8 | each | - | - |
| 1.006 | OD269073/2025-2026:Supply installation testing commissioning of Decorative Pole 3.2/3 meter height
above the
ground level made out of GI, tubular pole having two section section, bottom section
of
minimum 900/1000mm with base dia of 114mm and upper section of minimum
2300/2000mm
with minimum dia of 60mm. The pole shaft shall be as per IS 1161. The pole shall
have base plate of
dimension 200x200x12mm/round minimum 200mm including minimum16mm
diameter 4 numbers foundation bolts of
450mm bolt length, 200mm pitch circle diameter manufactured from special steel
along with
nuts, washers, The pole shall be with inbuilt control gear tray at bottom section. The
control
gear tray is prewired with 1.5 Sq.mm cable, 6A SP MCB and 32A stud type 4 way
terminal block for loop-in / loop-out arrangement, 6 A 2 Way terminal connector and
provision
for earthing.The pole shall be suitable for wind loadings as per IS 875 part 3 1987.
Design
comply EN40 standard and basic wind speed 169kmph. Pole should hot dip
galvanized to 65
microns to IS 2629:985/ IS 4759:1996 / IS 2633:1986. The Pole should be given with
two coats
of epoxy primer and above that it should be given marine coating. The complete
system should
be hot dipped Galvanised. (Crompton Deco/K lite COLOMBIA/Kesslec ECO). | 8 | each | - | - |
| 1.007 | OD362293/2025-2026:12000 lumen LED, efficacy >=120 Lm/watt, IP 66 flood light fitting with die-cast aluminium housing, polycarbonate cover complete with THD <10%, power factor >0.95, RoHS compliant, duly wired up for use on 230 V AC supply, IK >=7, with internal surge protection 4k above. Chip make Cree/Osram/lumilled/Nichea/Bridgelux.(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 6 | each | - | - |
| 1.008 | OD362323/2025-2026:4800 lumen LED, efficacy >=120 Lm/watt, IP 66 flood light fitting with die-cast aluminium housing, polycarbonate cover complete with THD <10%, power factor >0.95, RoHS compliant, duly wired up for use on 230 V AC supply, IK >=7, with internal surge protection 4k above. Chip make Cree/Osram/lumilled/Nichea/Bridgelux.(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 18 | each | - | - |
| 1.009 | OD277502/2025-2026:Supply Conveyance, installation, testing and commissioning of surface mounting low bay light
fittings of 30W , Initial LED luminaire efficacy 120 lm/W, CCT3500- 6500K With IP65 protection all types directly on
ceiling including giving connections with required length of 16/0.20 mm 3 core round copper
conductor flex wire conforming to relevant ISS or with the extended original wiring, making
good the damages, colour washing etc as required.( philips GreenUp Lowbay G2/equivalent) | 12 | each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_1476929.xls
BOQ • 0.33 MB
specificconditionNEW.pdf
Tender Documents • 0.34 MB
MOM.pdf
Tender Documents • 0.21 MB
viewnit.pdf
Tender Documents • 0.02 MB
viewsbd.pdf
Tender Documents • 2.72 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .