Loading…
Loading…
Tender Value
₹21.1 L
EMD Value
₹42,300
Closing Date
14 Aug 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
WORKS 2
12 conditions · 1 needing a document upload
Electrical contractor license: - The contractor should have valid electrical contractor license issued by government and submit along with tender document. If valid electrical contractor license is not submitted along with tender document, then offer will be summarily rejected.
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
2 conditions
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
I / We have visited the works site and I / We am / are aware of the site conditions.
Electric Work in c/w Proposed new block station between Mandore and Marwar Mathaniya station along with development of Goods shed at Manaklao station.
GSUELECTG-14of2026-27
GSUELECTG-14of2026-27
Open
Works - General
12 Months
Jodhpur, Rajasthan
₹0
₹42,300
14 Aug 2026
23 Jul 2026
31 Jul 2026
123 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 21,12,489.94 | ||
| — | 1.00 | — | — | ||
| Supply, installation, testing & commissioning of VTPN type metal double door type 8 way DB with having 01 No. 250Amp., 4 pole MCCB, 36 KA as incomer & 8 Nos. TP MCB, 10KA'C' curves, 40-63 Amp. Cap. As outgoing having suitable IP-54,IK-09protection. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 50,367.6 | |
| — | 80.00 | — | — | ||
| Supply of material & wiring of sub-main with 2x6 sq mm PVC insulated multi-strand ( 84 /.30 mm ) copper conductor cable in existing laid ( surface / recessed ) PVC conduit pipe and continuous running of PVC insulated copper earth wire of 1 Sq.mm. as per specifications attached as required. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 9,417.6 | |
| — | 200.00 | — | — | ||
| Supply of material & wiring of sub-main with 2x4 sq mm PVC insulated multi-strand ( 56 /0.3 mm ) cooper conductor cable in existing laid ( surface / recessed ) PVC conduit pipe and continuous running of PVC insulated copper earth wire of 1 Sq.mm. as per specifications attached as required. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 16,662 | |
| — | 500.00 | — | — | ||
| Supply of material & wiring of sub-main with 2x2.5 sq mm PVC insulated ( 36 /0.3 mm ) multi-strand copper conductor cable in existing laid ( surface / recessed ) PVC conduit pipe and continuous running of PVC insulated copper earth wire of 1 Sq.mm. as per specifications attached as required. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 32,715 | |
| — | 10.00 | — | — | ||
| Wiring of main (for individual qtr.) with 2x4 sq mm 56/.30 PVC insulated multi-strand copper cable in 19/20 mm dia MS conduit pipe to be fixed properly with saddles, gutties & other fixtures and continuous running of PVC insulated copper earth wire as per specifications attached. Including supply of material as required. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,220 | |
| — | 400.00 | — | — | ||
| Supply and Fixing of 20 mm dia medium class P.V.C. Pipe along with accessories as required in recess on walls/roof properly including cutting of wall /roof and making good the damages as per specifications attached. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 30,472 | |
| — | 100.00 | — | — | ||
| Supply of material and wiring of LP/TP/FP/Ex.Fan point with 1.5sqmm PVC single core multi-stranded copper wire insulated concealed in stone/brick masonry wall in19/20 mm PVC conduit with 1.5sqmm PVC wire insulated copper for earth wire 1-way/2-way switch 5/6A as required and good quality ceiling rose including connection (MODULAR)as per spec. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 37,209 | |
| — | 40.00 | — | — | ||
| Supply and fixing 5/6A plug 5-pin 230Vwith switch, board and wiring with 2.5sqmm PVC CU cable as per spec. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 7,787.6 | |
| — | 20.00 | — | — | ||
| Supply and fixing 15/16A power socket with switch on flush type sheet metal box and connection as per spec. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 3,873.4 | |
| — | 10.00 | — | — | ||
| Supply and fixing ceiling of fan regulator electronic type 5-step as per spec. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 3,221 | |
| — | 10.00 | — | — | ||
| Supply and fixing 12 module plate for fixing of switches and sheet metal box of good quality concealed fixing of MS/PVC. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 2,425.9 | |
| — | 10.00 | — | — | ||
| Supply and fixing 8 module plate for fixing of switches and sheet metal box of good quality concealed fixing of MS/PVC. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 2,201.6 | |
| — | 6.00 | — | — | ||
| Supply and fixing 6 module plate for fixing of switches and sheet metal box of good quality concealed fixing of MS/PVC. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,002.96 | |
| — | 5.00 | — | — | ||
| Supply and fixing 4 module plate for fixing of switches and sheet metal box of good quality concealed fixing of MS/PVC. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 656.3 | |
| — | 4.00 | — | — | ||
| Supply and fixing 2 module plate for fixing of switches and sheet metal box of good quality concealed fixing of MS/PVC. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 344.76 | |
| — | 20.00 | — | — | ||
| Supply, fixing and connecting modular type exhaust fan 225/250mm as per spec. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 15,252.2 | |
| — | 20.00 | — | — | ||
| Wiring of shed LP/TP in covered shed with 1.5sqmm copper wire PVC Wiring of shed LP/TP in covered shed with 1.5sqmm copper wire PVC insulated & multi-stranded in PVC conduit, ISI mark 1.5mm thick, size19/20mm dia and 1.5sqmm PVC insulated multistranded copper earth wire with ceiling rose fixed with saddles or tied properly and junction box as per spec.. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 3,451.8 | |
| — | 210.00 | — | — | ||
| Supply of material & commissioning of PVC casing caping 25X12 mm with accessories for surface wiring as per specification. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 4,819.5 | |
| — | 80.00 | — | — | ||
| Supply, Fixing of MCB to be provided in the MCBDB given above including supply of material as required & as per specifications attached-MCB (SP-) 6-32 A. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 18,053.6 | |
| — | 10.00 | — | — | ||
| Supply, Fixing of MCB to be provided in the MCBDB given above including supply of material as required & as per specifications attached-RCCB - 25 A/30mA. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 23,792.4 | |
| — | 10.00 | — | — | ||
| Supply. fixing, testing and commissioning of SPN DB 8-way with provision of incoming MCB of 63A,IP 43/IK09, double door at suitable locations. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 24,056.9 | |
| — | 1.00 | — | — | ||
| Supply, Fixing, testing and commissioning of TPN DB 8-way with provision of incoming MCCB of 125A, IP43/IK09, double door at suitable locations. (Inspection: Consignee, Inspection Charges: None | — | — | — | 14,474.29 | |
| — | 1.00 | — | — | ||
| Supply, Fixing of MCB to be provided in the MCBDB given above including supply of material as required & as per specifications attached- MCCB 4-pole 100/125A, 25 KA (Inspection: Consignee, Inspection Charges: None) | — | — | — | 13,033.26 | |
| — | 5.00 | — | — | ||
| Supply, fixing, testing and commissioning of RCBO 25A,RCBOdouble pole, 30mA with Earth leakage, overload and short circuit protection as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 10,772.9 | |
| — | 1.00 | — | — | ||
| Supply, fixing, testing and commissioning of RCBO 63A,RCBOFour pole, 30mA with Earth leakage, overload and short circuit protection as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 3,266.34 | |
| — | 6.00 | — | — | ||
| Supply, fixing, testing and connecting of wall mounted heavy duty Air Circulator of 24''(600mm) size with built in 3 speed regulator, delivers Air 280Cu.m/min, similar to M/s Almonard make with all accessories complete confirming to IS specification with latest amendments. The Air Circulator is to be fixed by suitable MS clamps of size 50x50x6mm / flats of size 40x6mm with bolts and nuts etc., complete as desired by site engineer. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 56,145.66 | |
| — | 10.00 | — | — | ||
| Supply, Testing & Fixing of wall mounted cabin fan with regulator three speed, suitable for 220- 230 volt ,50HZ AC supply .Model No-Media BW 04 of Bajaj or similar to Usha/ Crompton Greaves /Philips . (Inspection: Consignee, Inspection Charges: None) | — | — | — | 18,428.8 | |
| — | 2.00 | — | — | ||
| Supply and Fixing Re- roll plug socket 20 A with single pole 20A MCB & Re-roll plug top and as per specification. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,682.94 | |
| — | 10.00 | — | — | ||
| "B" Class 50 mm dia GI pipe earth Station with digging pit & refilling with charcoal & salt as per specification. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 13,006.4 | |
| — | 10.00 | — | — | ||
| Inspection Chamber with cover as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 3,627.6 | |
| — | 100.00 | — | — | ||
| Supply & laying of earth connection from earth electrode with 4 mm GI wire properly fixed on wall with wooden gutties etc. as required. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,101 | |
| — | 25.00 | — | — | ||
| Supplying., laying of GI pipe size 50 mm dia. B class as per IS1239 for cable use as per specification enclosed (Inspection: Consignee, Inspection Charges: None) | — | — | — | 8,079.25 | |
| — | 700.00 | — | — | ||
| laying cable in Air/Wall/Pole with fixture(02 nos. per mtrs) as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 15,981 | |
| — | 2300.00 | — | — | ||
| Supply and laying of HDPE pipe confirming to IS 4984:1995, 50 mm dia, wall thickness 3 mm, PN 6 under the road. The work involves laying of HDPE pipe. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 2,12,934 | |
| — | 2300.00 | — | — | ||
| Digging and filling of trench size 0.4 x 0.8 mtr as per spec ( trench work may be on kuchcha/ pucca land and all type of soil as per site requirement and without protective layer of brick). Surface of trench shall be made good in all respect and satisfaction of site engineer. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 87,860 | |
| — | 50.00 | — | — | ||
| Drilling of horizontal bore below track/road by pushing method for laying of RCC/HDPE/DWC pipe of various sizes (As per specifications) (Inspection: Consignee, Inspection Charges: None) | — | — | — | 66,856.5 | |
| — | 20.00 | — | — | ||
| Supply & laying of HDPE pipe, dia 160 mm under road/ground/floor/railway track or as per site requirement in already excavated trench. (As per specification) (Inspection: Consignee, Inspection Charges: None) | — | — | — | 14,835 | |
| — | 30.00 | — | — | ||
| Erection of 7 mtrs high single arm hot dip galvanized Steel Octagonal "Smart poles" with galvanized base plate of 220 x 220 x 12 mm Foundation PCD 205 & Bolt size (4x20 mm dia X 700 mm) length in position including excavation of pit and filling the same with concrete 50 cm ground level from base plate mounting including supply of material as required The pole shall be galvanized internally & externally by single dipping method .Make BAJAJ Model BOP -7030, GE, Crompton Greaves, Philips or similar to this model. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 3,50,837.7 | |
| — | 1.00 | — | — | ||
| Supply, erection, testing & commissioning of 12.50 Mtrs. High mast shaft totally hot dip galvanized and suitable for wind velocity as per IS 875 PART 3. The mast shaft shall be in two finished section. it shall also include accessories for 12.5 Mtrs. high mast including head frame, steel wire rope 6 mm dia. (7/19 construction ) double drum winch, galvanized lantern carriage arrangement suitable for 6 luminaries symmetrically and its control gear boxes and lighting finial with integral power tool. The work also include design and casting of suitable foundation bolts with M-15 Concrete for high mast considering the safe soil bearing capacity at site as 10T per Sq. mm at 2 Mtrs. depth. the foundation should be casted with foundation bolt manufactured with special steel along with nuts, washers, anchors plates and templates as required make: BAJAJ/PHILIPS.The mast shall have one longitudinal weld and single dipping (hot dip galvanized) per section (as per specification attached). (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,47,654.22 | |
| — | 1.00 | — | — | ||
| Supply & installation of control panel housing suitable timer contactor circuit for Automatic switch ON & switch OFF of the mast at a preset time. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 16,767.9 | |
| — | 1.00 | — | — | ||
| Supply and fixing of aviation light luminaires of BGAV 302 LED of Bajaj or similar comprising of aluminium housing with polycarbonate enclosure (1 fitting per mast is necessary if no taller structures are in the vicinity). Fitting should be of reputed make and as per tech. spec. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 3,963.51 | |
| — | 100.00 | — | — | ||
| Assembling, fixing, hanging and making connection of Surface pendent mounted box type tube light fitting/street light fitting as per specification. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 6,859 | |
| — | 1.00 | — | — | ||
| Supplying, fixing ,testing & commissioning Automatic operation street light timing switch box having lighting control (on-off) through astronomical calculation and pre-wired with suitable size of contactors, copper conductor etc. at specified locations as per specification attached and Similar to model no 04764 of LEGRAND make or similar of Siemens/ABB. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 19,621.47 | |
| — | 15.00 | — | — | ||
| Design, Manufacturer, Supply, fixing at Specified given locations and testing, commissioning of LED based station Name Board in Hindi/English as per given size of letters and as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,08,056.55 | |
| — | 1.00 | — | — | ||
| L.T. Panel-I Manufacturing, supplying, testing and commissioning of wall/floor mounted (as per site requirement) LT Distribution board with 01 No. 200 Amp. 4 pole 415 Volt, 50 Hz, thermal magnetic MCCB as incoming and 02 No.100 Amp. 4 pole MCCB, 03 Nos. 40 Amp. 4 pole MCCB as outgoing. .(As per Specification attached) (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,16,512.56 | |
| — | 40.00 | — | — | ||
| Supply, fixing, testing & connecting of LED backlit single sided signage boards withn IP-65 CRCA housing, vinyl print on acrylic sheet which is backlit with high grade, high brightness LED modules, inbuilt SMPS driver, without battery backup, operating voltage 80v-270V AC, life period >50000 hrs, LPM technology, including fabrication and supply of clamping arrangements as desired by site engineer. (Inspection: Consignee, Inspection Charges: None)) | — | — | — | 56,794.4 | |
| — | 40.00 | — | — | ||
| Supply, fixing, testing & connecting of LED backlit double sided signage boards withn IP-65 CRCA housing, vinyl print on acrylic sheet which is backlit with high grade, high brightness LED modules, inbuilt SMPS driver, without battery backup, operating voltage 80v-270V AC, life period >50000 hrs, LPM technology, including fabrication and supply of clamping arrangements as desired by site engineer. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,01,861.2 | |
| — | 13.00 | — | — | ||
| Supply of LED FLOOD LIGHT 150 Watt as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 29,874 | |
| — | 10.00 | — | — | ||
| Supply of Brushless Direct Current (BLDC) motor type Ceiling fan 1200 mm as per spec. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 22,990 | |
| — | 310.00 | — | — | ||
| Supply of 2 Core 70 sq mm XLPE insulated, PVC sheathed armoured Aluminium multistrand conductor cable 1100V grade, as per specification attached. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 32,379.5 | |
| — | 1.00 | — | — | ||
| Supply, fixing and commissioning of 60 Amp. Capacity 240 volts, 50 Hz. for 10 KVA AT automatic Change Over Control and Distribution panels for CLS as per Latest RDSO Specification No. TI/SPC/ PSI/CLS/ 0020 with A & C Slip 1 to 4. CORE approved drawing no.: COS/CORE/ 2005/01 Rev.02 or latest (Inspection: Consignee, Inspection Charges: None) | — | — | — | 48,442.14 | |
| — | 3.00 | — | — | ||
| Supply of material & provision of Strip Earth complete with digging of 15 meter trench/0.45meter width/0.6 meter depth and refilling with salt and charcoal as required. The earth should have masonry enclosure on top with hinged MS cover, as per specification. It should be properly packed and watered so that it may not sink in rainy season. The electrode should be provided with 0.5 meter length GI Pipe for Electrode coming out of ground. The earth value should be tested and displayed near the earth pit. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 14,594.07 | |
| — | 30.00 | — | — | ||
| Supply and fixing copper earth strip 25x3 mm and as per specification attached. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 11,936.7 | |
| — | 3.00 | — | — | ||
| Supply, Fixing of MCB TPN to be provided in the MCBDB including supply of material as required & as per specifications attached-MCB(TPN)-63A (Inspection: Consignee, Inspection Charges: None) | — | — | — | 5,922.06 | |
| — | 3.00 | — | — | ||
| Supply, Fixing of MCB TP 63A to be provided in the MCBDB including supply of material as required & as per specifications attached. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 5,877 | |
| — | 4.00 | — | — | ||
| Supply, fixing, testing and commissioning of fabricated Feeder Pillar distribution box made of MS sheet 1.6mmthick size 600x300x600mmwith suitable MS stand Copper bus bar of 200Acapacity and 2x63A MCB 4pole as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 21,624 | |
| — | 4.00 | — | — | ||
| Supply, fixing, testing & commissioning of three phase Electronic KWH meter make HPL Long Range meter model no. TPPB1U2314 or similar model (as per specifications attached) complete and earthed properly including supply of material. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 54,688 | |
| — | 4.00 | — | — | ||
| Supply of AC single phase static Energy Meter 5-30 A capacity to measure & display of unit (KWH), Ampere (I), Voltage (V), Load (KW), maximum demand (KW) including last six month history of Energy etc. of accuracy class 1.0, 240 V, 50 Hz with backlit LCD display confirming to IS:13779 or latest. Make: Indotech, L&T, HPL, CG, Genus. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 9,664 | |
| — | 10.00 | — | — | ||
| Fixing of ceiling fan with clamp, hooks and down rod as per requirement and connection asper spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,767.9 | |
| — | 100.00 | — | — | ||
| Supply, installation, testing & commissioning of (150 mm width x 50 mm depth x 1.6 mm thickness) perforated Hot Dipped Galvanized Iron Cable Tray (Galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections fixed with MS Angle frame duly painted of 35 mm x 5 mm thick and all hardware complete in all respect. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 69,999 | |
| — | 35.00 | — | — | ||
| Supply, installation, testing & commissioning of (100 mm width x 50 mm depth x 1.6 mm thickness) perforated Hot Dipped Galvanized Iron Cable Tray (Galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections fixed with MS Angle frame duly painted of 35 mm x 5 mm thick and all hardware complete in all respect.(Inspection: Consignee, Inspection Charges: None) | — | — | — | 22,715 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ACS1TO11COMPRESSED1_1.pdf
ATTACHMENT
TDGSU14of2026-27.pdf
ATTACHMENT
SORTECHNICALSPECGSU 14of202627
ATTACHMENT
SORTECHSPECGSUGoodshedManaklavGSU14of26-27_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .