Loading…
Loading…
Tender Value
₹1.3 Cr
EMD Value
₹2.6 L
Closing Date
5 Jun 2026, 2:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
SRDEEGTVC
15 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of "V/N" or "V" whichever is less where V= advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/audited , the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure -VI B, along with copies of Audited Balance sheet duly certified by the Chartered Accountant/Certificate from Chartered Accountant duly supported by Audited balance sheet.
ii) For electrical works, the contractor should have a valid electrical contractor license from the concerned statutory authority of any state of India. The electrical license should be in the name of the firm's or in the name of any authorized person of the tenderers firm. It must be ensured that the validity of electrical license should be valid during the entire contract period duly renewing at appropriate time for extending validity. If the tenderer hired the electrical license, authorization of the same should be submitted
13 conditions · 1 needing a document upload
All the tenderers/Contractors have to deposit full earnest money and tender document cost as stipulated for the tender, through online modes as permitted in IREPS application through multiple banks net banking, debit and credit cards . All documents related to Partnership deed/Joint venture/ Consortium/ MOU, duly signed by the notary public, should be uploaded failing which offer will be summarily rejected.
I/We also hereby agree to abide by the Indian Railways Standard General Conditions Of Contract, with all correction slips up-to- date and to carry out the work according to the Special Conditions of Contract and Specifications of materials and works as laid down by Railway in the annexed Special Conditions of contract , General Instructions and conditions , explanatory notes of schedule of work and Annexures.
I/We hereby Confirm that the rates, rebates and/or other financial terms, if any, quoted by us in the relevant fields of the Financial Bid page will only be the ruling terms for deciding the inter-se ranking, and any such condition having financial repercussions, if quoted by us anywhere else including attached documents shall not be considered for deciding inter-se ranking
However, Railways shall have the right to incorporate any such condition quoted by us, in the contract, at their discretion, if contract is placed on us.
Manual submission of EMD and cost of tender form cannot be entertained/Considered and hence no need of uploading the scanned copy of financial instruments
Whether GST registration available or not?
The contractor has to submit the EPF Code as per the EPFO Act and also has to submit a statement in this regard before signing the contract agreement.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The bidder has to fill in his quoted rate against each item in the Bid rate / Unit rate column. The bidding rate is Rs./ unit, the bidder has to quote his rate for the individual item only
Subsequent to the enforcement of GST Act, the modifications to Para-(a),clause 6, part I of Indian Railways Standard General condition of contract, July 2014 vide Railway Board letter No: 2017/CE/CT/4/GST(a) of 23/6/2017 is as detailed below: Clause No.6 - Care in submission of Tenders: (a)(i) Before submitting a tender, the tenderer will be deemed to have satisfied himself by actual inspection of the site and locality of the works, that all conditions liable to be encountered during the execution of the works are taken into account and that the rates he enters in the tender forms are adequate and all inclusive to accord with the provisions in Clause-37 of the Standard General Conditions of Contract for the completion of works to the entire satisfaction of the Engineer. (ii) Tenderers will examine the various provisions of The Central Goods and Services Tax Act, 2017 (CGST)/ Integrated Goods and Services Tax Act, 2017 (IGST)/Union Territory Goods and Services Tax Act, 2017 (UTGST)/respective state's State Goods and Services Tax Act (SGST) also, as notified by Central/State Govt & as amended from time to time and applicable taxes before bidding. Tenderers will ensure that full benefit of Input Tax Credit (ITC) likely to be availed by them is duly considered while quoting rates. iii) The successful tenderer who is liable to be registered under CGST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/UTGST/SGST Act to Railway immediately after the award of contract, without which no payment shall be release to the contractor. The contractor shall be responsible for deposition of applicable to the concerned authority. iv) In case the successful tenderer not able to be registered under CGST/IGST/UTGST/SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism (RCM) and deposit the same to the concerned authority. The contractor is liable to pay the taxes as stipulated in the GST Act and Rules and also should furnish the details of GST to deduct from the contractor's bill.
TVC Divn: DEN/N Jurisdiction: Raising & extension of platforms in 7 stns (Ernakulam, Ettumanur, Mulamthuruthy, Kanjiramittam, Kaduthurithy, Chottanikkara Road & Kumaranallur) - Electrical arrangement
V-EG-OT-05-2026-2027
V-EG-OT-05-2026-2027
Open
Works - General
270 Days
Thiruvananthapuram, Kerala
₹0
₹2.6 L
5 Jun 2026
12 May 2026
22 May 2026
63 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,27,85,489.75 | ||
| — | 6660.00 | — | — | ||
| Supply & laying of HDPE pipe of 50 mm dia, pressure rating up to 4 PN (Material grade PE 63) conforming to IS 4984 /1995 in the excavated cable trench and threading of LTUG cable through the pipe and termination of either ends in a standard manner with suitable size heat zinc sleeve (Cable will be supplied free, departmentally at TVC and transportation will be provided by railway. Loading and un-loading operation has to be arranged by contractor) | — | — | — | 10,65,600 | |
| — | 300.00 | — | — | ||
| Clamping of LTUG cable 4 core x 70 sq.mm along PF Shelter /FOB/Building wall complete with 25 x 3 mm GI fixing hardware including termination on looping boxes /Kiyosk/Switch room. (Cable will be supplied free, departmentally at TVC and transportation will be provided by railway. Loading and un-loading operation has to be arranged by contractor). | — | — | — | 24,600 | |
| — | 450.00 | — | — | ||
| Clamping of LTUG cable 4 core x 25 sq.mm along PF Shelter /FOB/Building wall complete with suitable GI fixing hardware including termination on looping boxes /Kiyosk/Switch room.(Cable will be supplied free, departmentally at TVC and transportation will be provided by railway. Loading and un-loading operation has to be arranged by contractor) | — | — | — | 32,850 | |
| — | 12.00 | — | — | ||
| Supply And fixing of cable gland suitable for LTUG cable 4 core x 70 Sq.mm and termination using aluminium socket duly crimped with suitable size heat sinc sleeve | — | — | — | 4,044 | |
| — | 28.00 | — | — | ||
| Supply And fixing of cable gland suitable for LTUG cable 4 core x 25 Sq.mm and termination using aluminium socket duly crimped with suitable size heat sinc sleeve | — | — | — | 8,120 | |
| — | 4.00 | — | — | ||
| Supply and concealing/ fixing of metal box of suitable size fitted with 200 A, 4 P Brass connector | — | — | — | 9,800 | |
| — | 40.00 | — | — | ||
| Supply & fixing/concealing of ivory colour ISI marked PVC pipe 32 mm dia x 2/2.5 mm thick conforming to IS 9537 (PART-3), in a open manner complete with bend, Ts, etc with fixing hardware (Clamping to be done at a spacing not more than 75 cm on the building wall/roof) | — | — | — | 6,240 | |
| — | 40.00 | — | — | ||
| Supply & drawing of PVC insulated FRLS copper cable of 10.0sq.mm Four runs & 10 sq mm one run as earth wire conforming to IS 694, through 32 mm PVC conduit mentioned including termination in a standard manner as required at site | — | — | — | 20,640 | |
| — | 4.00 | — | — | ||
| Supply, erection testing and commissioning of MCB 6 Way Vertical Distribution Board , three phase ( 8+18 modules) IP-43 protected, CRCA sheet enclosure powder coated with suitably rated insulated copper bus bars for phase, with neutral & earth bars, shrouds, cement spill protector, color coded inter-connecting wire sets, cable ties etc as applicable and fitted with the following accessories one (1) one No. 63 A 4P MCB & (2) one No 63 A 4P 100 mA RCCB as incommer (3) one No. 25 A 3 P MCB (4) 10 Nos 6 to 32 A SP MCB as out going in a concealed/open manner as required at site. The MCCB/MCBs shall be IS/IEC certified. | — | — | — | 1,06,340 | |
| — | 4.00 | — | — | ||
| Fabrication, supply, erection and commissioning of in door type metal box of size 600 x 600 x 300 mm size fabricated out of 14 SWG CRCA sheet poweder coated finish and fitted with (1) One No. mechanical quartz clock timer switch with cycle duration of 24 hrs working in 230 V 50 Hz AC supply (2) Two Nos. Off-delay timer (3)Three Nos. 25 A contactor (4) three Nos. 32 A SP MCB & (5) 200 A 4 way connector ( fabricated with four Nos of brass/copper nut/bolt with washer fitted in 12 mm SMC sheet as cable connector including fixing hardware and locking arrangements. Provision has to be given for cable glands) (20% & 80% PF light control) | — | — | — | 82,740 | |
| — | 3.00 | — | — | ||
| Manufacture, Supply & fixing of integrated pre-cooling socket in MS enclosure fabricated out of 14 SWG sheet (Rail/Stanchion mounting type with front opening door & hinges from inside) epoxy powder coated & fitted with 5 mm thick SMC sheet base, 1 No 63 A TPN MCCB (25 KA), 1 No 63 A 4 Pole ELCB/RCCB( 300 mA), 1 No 63 A capacity, 5 pin heavy duty metal clad plug socket, 4 Nos 25 x 6 mm copper bus bars etc as per drawing No V/E.G/411 completely pre-wired using 16 sq.mm PVC insulated copper wire (Bottom plate to be used shall be of 10 SWG ) complete with 50 x 6 mm MS painted fixing hardware | — | — | — | 86,097 | |
| — | 30.00 | — | — | ||
| Supply & drawing of PVC insulated FRLS copper cable of 16.0sq.mm four runs & 16 sq mm one run as earth wire conforming to IS 694, through PVC conduit mentioned including termination in a standard manner as required at site (MCCB to DB) | — | — | — | 20,490 | |
| — | 1773.00 | — | — | ||
| Excavation of cable trench 0.3 m wide x 1.0 m deep (preferably) in ordinary soil, back filling of the excavated cable trench (After laying of cables) , ramming & consolidation properly | — | — | — | 8,40,402 | |
| — | 187.00 | — | — | ||
| Excavation of cable trench 0.3 m wide x 0.1 m deep (up to the depth of tarr/concrete) in tarred/concreted surface back filling of the excavated cable trench After laying of cables), ramming & consolidation properly. | — | — | — | 3,65,959 | |
| — | 187.00 | — | — | ||
| Concreting the top portion of the cable trench excavated in tarred/concreted surface to a depth of 10.0 cm, using 1:2:4 mix with M sand | — | — | — | 16,44,291 | |
| — | 22.50 | — | — | ||
| Excavation of cable trench 0.3m wide x 1.0 m deep under/side of railway tracks, duly removing stone ballast, back filling of the excavated cable trench (After laying of cable with HDPE pipe), ramming & consolidation properly and providing back the removed stone ballasts (The work should be carried out very carefully since space constraints and care should be exercised to protect signal cables) | — | — | — | 30,735 | |
| — | 3.00 | — | — | ||
| Design , supply, installation, testing and commissioning of three phase grid connected solar plants of 5 KWp capacity with mono PERC half cut PV modules complete with suitable mounting structures for fixing the PV modules on roof top with stainless steel nuts and bolts, grid-tie inverter of 5KVA capacity with all accessories, bidirectional meter for net metering, grid synchronization, DC/AC cabling, surge protection, lightning arrester and earthing arrangements' as per MNRE specification complete with al accessories. | — | — | — | 5,46,327 | |
| — | 53.00 | — | — | ||
| Double Arm: Supply and errection of 4 M high galvanised octagonal pole as per Specification No. V/E.SPEC/284(R1) with 70 mm top dia, 130 mm bottom dia, 3mm thick sheet and 200 x 200 x 10 mm base plate with 4 Nos. 20mm dia and 450 mm long GI foundation bolts including 450 mm long double arm GI bracket | — | — | — | 10,51,096 | |
| — | 201.00 | — | — | ||
| Supply and errection of 4 M high galvanised octagonal pole as per Specification No. V/E.SPEC/284(R1) with 70 mm top dia, 130 mm bottom dia, 3mm thick sheet and 200 x 200 x 10 mm base plate with 4 Nos. 20mm dia and 450 mm long GI foundation bolts including 1 No. 600 mm long single arm GI bracket | — | — | — | 35,92,071 | |
| — | 15.00 | — | — | ||
| Errection of 4 M high galvanised octagonal pole with 4 Nos. 20mm dia and 450 mm long GI foundation bolts . Octagonal pole will be supplied by Railway | — | — | — | 60,000 | |
| — | 24.00 | — | — | ||
| Fixing of 5 Star rated BLDC ceiling fan | — | — | — | 5,760 | |
| — | 10.00 | — | — | ||
| Supply installation testing and commissioning of aesthetically designed mobile phone charger with plug sockets complete with internal wiring by using 1.5sqmm copper cable. The box contain 6 Nos. of 6A sockets and single phase 30.0mA sensitivity RCCB as per the drawing attached | — | — | — | 65,000 | |
| — | 307.00 | — | — | ||
| Supply & fixing of LED street light fitting 33 + 3 watts complete with driver assembly, pressure die cast aluminium housing, toughened glass cover conforming to IP 66 protection including supply connection with replacement warranty period of 5 years | — | — | — | 8,28,900 | |
| — | 67.25 | — | — | ||
| Design and casting of M-15 RCC foundation with 8mm steel rods reinforcement to octagonal pole complete with materials. | — | — | — | 12,17,964.75 | |
| — | 269.00 | — | — | ||
| Supply and fixing of 1 No. 16A fuse unit, 1 No. 20 A 4 way SMC connector in 5 mm thick SMC sheet in side the octagonal pole with suitable fixing hardware | — | — | — | 1,80,768 | |
| — | 322.00 | — | — | ||
| Supply & wiring to /street light luminaire points through octagonal pole with 3 core 1.5 sq. mm PVC insulated Cu wire | — | — | — | 1,86,438 | |
| — | 95.00 | — | — | ||
| Cutting & stacking of existing rail post/tubular post/ Octagonal post/solar light post in a convenient location as per the instruction of SSE in charge including removal of coping and levelling the ground by concrete/plastering | — | — | — | 2,01,780 | |
| Lumpsum | 1.00 | — | — | ||
| Cutting & stacking of existing Old light tower in a convenient location as per the instruction of SSE in charge | — | — | — | 15,000 | |
| — | 8410.00 | — | — | ||
| Supply and laying of 8 SWG GI wire and termination on either end as required at site | — | — | — | 2,01,840 | |
| — | 205.00 | — | — | ||
| Supply and laying/fixing of GI earth strip of size 25X3 mm and termination as required at site | — | — | — | 28,700 | |
| — | 41.00 | — | — | ||
| Provision of pipe earthing arrangements as per drg No. V/E.29/2025-26 | — | — | — | 2,54,897 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Earthing
ATTACHMENT
Pree cooling bunk
ATTACHMENT
TenderDocument_1.pdf
ATTACHMENT
DrgV-E-29-25-26-LTEARTHING.pdf
ATTACHMENT
411400v63APre-coolingPlug_AutoDWG.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .