Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.2 LAccepted-Finance | ₹10.2 L | L1 | Accepted-Finance LOWEST |
| 2 | L2₹12.7 LRejected-Finance | ₹12.7 L | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹14.0 LRejected-Finance | ₹14.0 L | L3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | L4₹14.0 LRejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹14.0 L | L4 | Rejected-Finance OTHER THAN LOWEST |
| 5 | L5₹14.2 LRejected-Finance | ₹14.2 L | L5 | Rejected-Finance OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | SSV Infra L5 | satpal and brothers L4 | PARGAL CONSTRUCTION CO L6 | M/S PRAJAPATI ENGINEERS L3 | Vishav Karma Refrigeration and Electric Work L7 | M/S PYRAMID CONSTRUCTIONS L2 | dinesh enterprises L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Maintenance and repair to existing street / perimeter security lights fittings / solar lights etc of any type / size/wattage from date of work order / physically handing over site to contractor as nature the work is of urgent requirement keeping security of areas and any specifications, fittings / fixed of poles, buildings or watching towers of any heights, finding faults in LT feeder and light fittings, liasoning with connectioning sub station of MES, reporting to concerned JE E/M and Engr-in-Charge about the faults complete manpower for repair including rectifying the same by replacing defective spare parts as per direction by concerned JE E/M and Engr-in-Charge at various location complete all as specified and directed (Zone-I).
Note :- 1. Spare parts of light fitting / fitting shall be measured and paid separately under relevant items of Schedule 'A' as supply only as per requirement for repair / replacement however providing manpower on daily basis as quoted above. | 1,500 | Each | 40 ₹60,000 | 80 ₹1.2 L | 50 ₹75,000 | 136 ₹2.0 L | 69 ₹1.0 L | 45 ₹67,500 | 50 ₹75,000 |
| 2.00 | Maintenance and repair to existing street / perimeter security lights fittings / solar lights etc of any type / size/wattage from date of work order / physically handing over site to contractor as nature the work is of urgent requirement keeping security of areas and any specifications, fittings / fixed of poles, buildings or watching towers of any heights, finding faults in LT feeder and light fittings, liasoning with connectioning sub station of MES, reporting to concerned JE E/M and Engr-in-Charge about the faults complete manpower for repair including rectifying the same by replacing defective spare parts as per direction by concerned JE E/M and Engr-in-Charge at various location complete all as specified and directed (Zone-II).
Note :- 1. Spare parts of light fitting / fitting shall be measured and paid separately under relevant items of Schedule 'A' as supply only as per requirement for repair / replacement however providing manpower on daily basis as quoted above. | 1,500 | Each | 40 ₹60,000 | 80 ₹1.2 L | 60 ₹90,000 | 130 ₹1.9 L | 69 ₹1.0 L | 35 ₹52,500 | 50 ₹75,000 |
| 3.00 | Maintenance and repair to existing street / perimeter security lights fittings / solar lights etc of any type / size/wattage from date of work order / physically handing over site to contractor as nature the work is of urgent requirement keeping security of areas and any specifications, fittings / fixed of poles, buildings or watching towers of any heights, finding faults in LT feeder and light fittings, liasoning with connectioning sub station of MES, reporting to concerned JE E/M and Engr-in-Charge about the faults complete manpower for repair including rectifying the same by replacing defective spare parts as per direction by concerned JE E/M and Engr-in-Charge at various location complete all as specified and directed (Zone-III).
Note :- 1. Spare parts of light fitting / fitting shall be measured and paid separately under relevant items of Schedule 'A' as supply only as per requirement for repair / replacement however providing manpower on daily basis as quoted above. | 350 | Each | 45 ₹15,750 | 80 ₹28,000 | 70 ₹24,500 | 130 ₹45,500 | 89 ₹31,150 | 85 ₹29,750 | 50 ₹17,500 |
| 4.00 | Supply onlyLED street light driver of capacity 100 watt, make of LED driver as per suitable light fitting of make and type as per sample complete all as specified and directed | 200 | Each | 325 ₹65,000 | 400 ₹80,000 | 1,200 ₹2.4 L | 200 ₹40,000 | 449 ₹89,800 | 585 ₹1.2 L | 300 ₹60,000 |
| 5.00 | Replacement of old UNSV / damaged street light fitting any type and S & F 60 Watt LED fitting new generation energy saving and environmental friendly long life LED street light fitting made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeddedPC cover with IP66 protection and impact resistance of IK07 complete including 2 RM, 2 core, 1.5 Sqmm copper wire for each light fitting etc complete all as specified and directed. | 112 | Each | 1,850 ₹2.1 L | 1,800 ₹2.0 L | 2,200 ₹2.5 L | 1,600 ₹1.8 L | 2,449 ₹2.7 L | 2,425 ₹2.7 L | 1,500 ₹1.7 L |
| 6.00 | Replacement of old UNSV / damaged street light fitting any type and S & F LED Flood Light luminaire in pressure die-cast aluminium housing with IP66 protection 60 watts, 230 volts, 50 Hz, area lighting including 60 watts LEDs and driver. | 132 | Each | 1,950 ₹2.6 L | 1,900 ₹2.5 L | 2,200 ₹2.9 L | 1,800 ₹2.4 L | 2,449 ₹3.2 L | 1,539 ₹2.0 L | 1,100 ₹1.5 L |
| 7.00 | Replacement of old UNSV / damaged street light fitting any type and S & F LED Flood Light luminaire in pressure die-cast aluminium housing with IP66 protection 70 watts, 230 volts, 70 Hz, area lighting including 60 watts LEDs and driver. | 41 | Each | 2,000 ₹82,000 | 2,000 ₹82,000 | 2,000 ₹82,000 | 2,000 ₹82,000 | 2,449 ₹1.0 L | 2,025 ₹83,025 | 1,500 ₹61,500 |
| 8.00 | Replacement of old UNSV / damaged street light fitting any type and S & F LED Flood Light luminaire in pressure die-cast aluminium housing with IP66 protection 50 watts, 230 volts, 50 Hz, area lighting including 50 watts LEDs and driver. | 191 | Each | 1,985 ₹3.8 L | 1,800 ₹3.4 L | 1,500 ₹2.9 L | 1,600 ₹3.1 L | 2,449 ₹4.7 L | 1,589 ₹3.0 L | 1,200 ₹2.3 L |
| 9.00 | Replacement of old UNSV / damaged street light fitting any type and S & F LED Flood Light luminaire in pressure die-cast aluminium housing with IP66 protection 100 watts, 230 volts, 50 Hz, area lighting including 100 watts LEDs and driver. | 5 | Each | 2,100 ₹10,500 | 2,000 ₹10,000 | 2,800 ₹14,000 | 2,600 ₹13,000 | 4,449 ₹22,245 | 2,445 ₹12,225 | 1,300 ₹6,500 |
| 10.00 | Supply and fixing in repair and replacment of Gate lights made out of aluminium die cast with modern artistic design and white PC diffuser suitable with LED lamp B-22 7.5 Watt LED Filament lamp all as specified and directed by Engr-in-Charge. Note: Necessary PCC work for fixing on gate rate deemed to be included on the quoted rate. The GI pipe of required size measured and paid separtely if required on site. | 10 | Each | 1,250 ₹12,500 | 2,500 ₹25,000 | 1,600 ₹16,000 | 2,500 ₹25,000 | 4,449 ₹44,490 | 1,123 ₹11,230 | 2,300 ₹23,000 |
Updated dates
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
6 May 2026, 6:00 pmClosed
GE SAMBA
GE SAMBA PIN 184121
REPAIR MAINTENANCE OF PERIMETER LIGHTS AND OTHER CONNECTED WORKS AT ZONE I II UNDER GE SAMBA
2026_MES_759539_1
8166/GE/SMB/T-11/2026-27
Open Tender
Miscellaneous Works
180 days
GE SAMBA
Class E Cat b i
8 documents required · 8 mandatory
₹500
GE SAMBA
₹40,000
Yes
16 Jun 2026
8 Apr 2026
9 May 2026
8 Apr 2026
6 May 2026
22 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
Maintenance and repair to existing street / perimeter security lights fittings / solar lights etc of any type / size/wattage from date of work order / physically handing over site to contractor as nature the work is of urgent requirement keeping security of areas and any specifications, fittings / fixed of poles, buildings or watching towers of any heights, finding faults in LT feeder and light fittings, liasoning with connectioning sub station of MES, reporting to concerned JE E/M and Engr-in-Charge about the faults complete manpower for repair including rectifying the same by replacing defective spare parts as per direction by concerned JE E/M and Engr-in-Charge at various location complete all as specified and directed (Zone-I).
Note :- 1. Spare parts of light fitting / fitting shall be measured and paid separately under relevant items of Schedule 'A' as supply only as per requirement for repair / replacement however providing manpower on daily basis as quoted above. | 1,500 | Each | - | - | |
Maintenance and repair to existing street / perimeter security lights fittings / solar lights etc of any type / size/wattage from date of work order / physically handing over site to contractor as nature the work is of urgent requirement keeping security of areas and any specifications, fittings / fixed of poles, buildings or watching towers of any heights, finding faults in LT feeder and light fittings, liasoning with connectioning sub station of MES, reporting to concerned JE E/M and Engr-in-Charge about the faults complete manpower for repair including rectifying the same by replacing defective spare parts as per direction by concerned JE E/M and Engr-in-Charge at various location complete all as specified and directed (Zone-II).
Note :- 1. Spare parts of light fitting / fitting shall be measured and paid separately under relevant items of Schedule 'A' as supply only as per requirement for repair / replacement however providing manpower on daily basis as quoted above. | 1,500 | Each | - | - | |
Maintenance and repair to existing street / perimeter security lights fittings / solar lights etc of any type / size/wattage from date of work order / physically handing over site to contractor as nature the work is of urgent requirement keeping security of areas and any specifications, fittings / fixed of poles, buildings or watching towers of any heights, finding faults in LT feeder and light fittings, liasoning with connectioning sub station of MES, reporting to concerned JE E/M and Engr-in-Charge about the faults complete manpower for repair including rectifying the same by replacing defective spare parts as per direction by concerned JE E/M and Engr-in-Charge at various location complete all as specified and directed (Zone-III).
Note :- 1. Spare parts of light fitting / fitting shall be measured and paid separately under relevant items of Schedule 'A' as supply only as per requirement for repair / replacement however providing manpower on daily basis as quoted above. | 350 | Each | - | - | |
Supply onlyLED street light driver of capacity 100 watt, make of LED driver as per suitable light fitting of make and type as per sample complete all as specified and directed | 200 | Each | - | - | |
Replacement of old UNSV / damaged street light fitting any type and S & F 60 Watt LED fitting new generation energy saving and environmental friendly long life LED street light fitting made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeddedPC cover with IP66 protection and impact resistance of IK07 complete including 2 RM, 2 core, 1.5 Sqmm copper wire for each light fitting etc complete all as specified and directed. | 112 | Each | - | - | |
Replacement of old UNSV / damaged street light fitting any type and S & F LED Flood Light luminaire in pressure die-cast aluminium housing with IP66 protection 60 watts, 230 volts, 50 Hz, area lighting including 60 watts LEDs and driver. | 132 | Each | - | - | |
Replacement of old UNSV / damaged street light fitting any type and S & F LED Flood Light luminaire in pressure die-cast aluminium housing with IP66 protection 70 watts, 230 volts, 70 Hz, area lighting including 60 watts LEDs and driver. | 41 | Each | - | - | |
Replacement of old UNSV / damaged street light fitting any type and S & F LED Flood Light luminaire in pressure die-cast aluminium housing with IP66 protection 50 watts, 230 volts, 50 Hz, area lighting including 50 watts LEDs and driver. | 191 | Each | - | - | |
Replacement of old UNSV / damaged street light fitting any type and S & F LED Flood Light luminaire in pressure die-cast aluminium housing with IP66 protection 100 watts, 230 volts, 50 Hz, area lighting including 100 watts LEDs and driver. | 5 | Each | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
TenderDocuments11.pdf
Tender Documents • 0.81 MB
BOQ_850750.xls
BOQ • 3.80 MB
Download all tender documents and submit your bid