Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance SHOP NO 31 FAIRDEAL SHOPPING COMPLEX RESIDENCY ROAD SRINAGAR RESIDENCY ROAD SRINAGAR JAMMU KASHMIR 190001 | SRINAGAR | JAMMU AND KASHMIR | 190001 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance MIR BUILDING HAZURI BAGH SRINAGAR JAMMU KASHMIR 190001 | SRINAGAR | JAMMU AND KASHMIR | 190001 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance 2ND FLOOR NO 3 BISMILLAH TRADE CENTRE CHOTTA BAZAAR KARANAGAR SRINAGAR JAMMU KASHMIR 190001 | SRINAGAR | JAMMU AND KASHMIR | 190001 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Not Admitted-Fee/PreQual/Technical/Finance | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
2 Mar 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Principal, Govt. Degree College Baramulla
Govt. Degree College Baramulla
Supply, installation, testing and commissioning of HPLC Equipment
2021_HED_117555_1
NIT-06
Open Tender
Laboratory and scientific equipment
Item Wise
15 days
Govt. Degree College Baramulla
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Principal, Govt. Degree College Baramulla
₹40,000
2 Mar 2021
20 Feb 2021
2 Mar 2021
20 Feb 2021
2 Mar 2021
20 Feb 2021
90 days
Amount
HPLC SYSTEM WITH PDA Component wise Specifications: 1. HPLC Pump (or delivery system) • High Pressure binary gradient Two pump System. • The machine should be operable both in isocratic and gradient mode. • The flow rate: 0.001 to 10 ml/min with the possibility of increment of 0.01 ml/min • Flow Precision: ≤ 0.1% RSD or better. • Delay Volume : <250µl (with Gradient Mixer). • Max. Operating pressure: 6000 psi or more. • Should have possibility to operate in various gradient curve mode including Linear, Step, concave, convex etc. 2. Column Oven • Should have provision for housing at least two or more columns • Temperature setting rage: 5 degree above Ambient to 60oC or better 3. PDA Detector • The detector should have wavelength range of 190-800 nm or more with wavelength accuracy of ± 1 nm • Wavelength Repeatability: ± 0.1 nm • Should be operable at high resolution mode (Resolution : 1.2 nm per photodiode) with a total of more than 512 Photo diodes, digital, and optical (3D mode) • Should be operable at noise level 1x10-5 AU at 254 nm or better • Data Acquisition : Up to 80 Hz or better • Path-length : 10 mm or better, Volume: 10ul or lesser. • Lamp optimization software to maintain light energy. • Deuterium lamp should be used as light source with minimum life of 2000 hrs or more. • Data Acquisition: Up to 80 Hz 4. Software • The software should be original, authenticated. • Should have option for versatility for multitasking without multiple software packages. • Customizable data reports, online help and answer wizards. • Should have option for data integrity along with advanced security measures • Licenced Oracle Database must be supplied separately or embedded in software. Columns • Analytical Column C18 RP (250 x 4.6 mm x 5μ) - 1 No Warranty: Minimum One Year Onsite, extended upto 2 Years
HPLC SYSTEM WITH PDA Optional Component Specifications Auto sampler • The auto-sampler should work with injection volume range of 0.2 to 1000 μl with possibility of 1μl increment or better. • Vial tray holder should have option for 96 vials or more of 2ml. • Injection Reproducibility: RSD <0.3% or better. • Carry over: <0.05% or better. • Auto sampler with provision of washing between injections with variable injection volume • With provision of programming of priority sample. • Should be at least 500 or more sample vials of standard size capacities with caps and septa. • Should have capacity to detect missing vials/well in the plates by an auto sensing system.
HPLC SYSTEM WITH PDA Optional Component Specifications Manual sampler • System should be quoted with Manual Sampling with 20,50 and 200ul loops and syringes
siab surgiments
M/S CHOICE CORNER BOMBAY DYEING
stage.html
html • 0.02 MB
finance_225462.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .