REPAIR TO STREET LIGHTS, LT CABLES AND ASSOCIATE WORKS AT AF STN JODHPUR
2020_MES_387548_1
8426/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Jodhpur
As per NIT
6 documents required · 6 mandatory
₹500
GE (AF) Jodhpur
₹40,000
Yes
1 Dec 2020
17 Oct 2020
13 Nov 2020
17 Oct 2020
12 Nov 2020
31 Oct 2020
Amount
Supply and fixing in replacement of automatic street light timer using nature switch for automatic switching of street light based on LUX level of natural light .The sensor (nature switch) along with suitable power contactor, MCB and support terminal should be enclosed in pole/wall mountable enclosure made of rust proof ,electric shock proof ,termite proof and FF grade SMC junction box (sintex make) confirming to IP 54 suitable for three phase phase of 05 KW model -Swadeep -02EC05kW3P of Make - Nature switch or equivalent in Legrand/Siemens/GE/L&T as approved by the GE.
Supply & fixing in repairs Energy saving LED street light of 90 Watt capacity with built in control box (IP66) suitable for outdoor application fixed on PCC Block with all connecting items like clamps, nut bolts complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs Energy saving LED flood of 120 Watt capacity with built in control box suitable for out door application complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs of energy efficient IP-66 LED Street flood light fitting of 100 watt, pole mounting comprising a diecast aluminium housing with all accessories complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs of energy efficient IP-66 LED Street flood light fitting of 200 watt, pole mounting comprising a diecast aluminium housing with all accessories complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs Aviation obstruction LED light fitting 240 volt low intensity twin aviation light of power consumption 10 watt in total, mounting on walls/Poles complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement of liner of suitable size for DG set of capacity 125 KVA, Make : Kirloskar, 415 Volts, 50 Hz , complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement of Piston of suitable size for DG set of capacity 125 KVA, Make : Kirloskar, 415 Volts, 50 Hz , complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement of Tepid Valve of suitable size for DG set of capacity 125 KVA, Make : Kirloskar, 415 Volts, 50 Hz , complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement of Piston Ring of suitable size for DG set of capacity 125 KVA, Make : Kirloskar, 415 Volts, 50 Hz , complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement of Engine Gaskit of suitable size for DG set of capacity 125 KVA, Make : Kirloskar, 415 Volts, 50 Hz , complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement of fuel injector pump of suitable size for DG set of capacity 125 KVA, Make : Kirloskar, 415 Volts, 50 Hz , complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement of O Ring Set of suitable size for DG set of capacity 125 KVA, Make : Kirloskar, 415 Volts, 50 Hz , complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for Calibration of Fuel injector pump of DG set of capacity 125 KVA, Make : Kirloskar, 415 Volts, 50 Hz to the entire satisfaction of Engineer in Charge.
Supply & fixing in replacement of Nosal of suitable size for DG set of capacity 125 KVA, Make : Kirloskar, 415 Volts, 50 Hz , complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement of Delivery Valve of suitable size for DG set of capacity 125 KVA, Make : Kirloskar, 415 Volts, 50 Hz , complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement of CR Bearing of suitable size for DG set of capacity 125 KVA, Make : Kirloskar, 415 Volts, 50 Hz , complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement of Main Bearing of suitable size for DG set of capacity 125 KVA, Make : Kirloskar, 415 Volts, 50 Hz , complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for disconnecting , dismantling & taking down the Engine head of DG set capacity 125 KVA, of Make : Kirloskar, 415 Volts, 50 Hz and repairs the engine head & make it functional to the entire satisfaction the Engineer-in-Charge.
Supply & fixing in replacement of Water body of suitable size for DG set of capacity upto 400 KVA, as per existing make complete all as specified and directed by the Engineer-in-Charge.
Disconnecting , dismantling & taking down old unserviceable AMF panel and Supply, installation, testing and commissioning of AMF Panel outdoor type, for 100 KVA CUMMINS DG Set with alluminium busbar of capacity 300Amps, TPN powder coated (coloured ) heat shrinkable sleeves, 3.15 mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of 250Amps consisting the following:-
INCOMING from 100 KVA (i) MCCB 200 Amp FP 25 KA with M/P Basd overcurrent & short circuit protection - 01 No (ii) Spreaders 250 Amps FP - 01 Set (iii) Extended Rotary handle 250 Amps FP - 01 No (iv) Earth fault module 250 Amp FP - 01 No (v) Power Contactor 200 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC - 01 No (vi) C.T. 250/5A CL-1.0 10 VA - 03 Nos (vii) Digital MF meter 96 x 96 mm with 485 Port CL 1.0 - 01 No (viii) Indicating lights (Red-4, Yellow-2. Green-2) (ix) Control MCB 6A SP 10 KA C curve - 03 Nos (x) VMR - 01 No (xi) In built on load change over switch 250 A for bypassing of AMF panel - 01 No
Outgoing (i) MCCB 200 Amp FP 25 KA with M/P Basd overcurrent & short circuit protection - 01 No (ii) Power Contactor 200 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No (iiI) AMF relay - 06 Nos (iv) SMPS 12V, DC, 10A - 01 No (v) Emergency stop P.B - 01 No (vi) Digital Amp meter 24V, DC - 01 No (vii) Digital Volt meter 24V, DC - 01 No (viii) Control MCB 6A SP 10 KA C Curve - 03 Nos (ix) Hooter - 01 No (x) PROCOM UNIT (DGC6D) FOR control - 01 No
Disconnecting , dismantling & taking down old unserviceable AMF panel and Supply, installation, testing and commissioning of AMF Panel outdoor type, for 82.5 KVA CUMMINS DG Set with alluminium busbar of capacity 300Amps, TPN powder coated (coloured ) heat shrinkable sleeves, 3.15 mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of 200Amps consisting the following:-
INCOMING from 82.5 KVA (i) MCCB 160 Amps FP 25 KA with M/P Basd overcurrent & short circuit protection -01 No (ii) Spreaders 200 Amps FP - 01 Set (iii) Extended Rotary handle 200 Amps FP - 01 No (iv) Earth fault module 200 Amp FP - 01 No (v) Power Cont. 160 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No (vi) C.T. 250/5A CL-1.0 10 VA - 03 Nos (vii) Digital MF meter 96 x 96 mm with 485 Port CL 1.0 - 01 No (viii) Indicating lights (Red-4, Yellow-2. Green-2) (ix) Control MCB 6A SP 10 KA C curve - 03 Nos (x) VMR - 01 No (xi) In built on load change over switch 250 A for bypassing of AMF panel - 01 No
Outgoing (i) MCCB 160 A FP 25 KA with M/P Basd overcurrent & short circuit protection - 01 No (ii) Power Cont. 160 A FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No (iiI) AMF relay - 06 Nos (iv) SMPS 12V, DC, 10A - 01 No (v) Emergency stop P.B - 01 No (vi) Dig Ammeter 24V, DC - 01 No (vii) Dig Voltmeter 24V, DC - 01 No (viii) Control MCB 6A SP 10 KA C Curve - 03 Nos (ix) Hooter - 01 No (x) PROCOM UNIT (DGC6D) FOR control - 01 No
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 Sqmm 2 Core nominal cross section in service connections complete all as specified and directed by the Engineer-in-Charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 Sqmm 2 Core nominal cross section in service connections complete all as specified and directed by the Engineer-in-Charge.
Attending day to day street / security light (LED, Flood light fittings of any make, installed at Dispersal & High mast light poles, Sun Shelter lights, Hanger lights, perimeter lights, watch tower lights etc at AF station jodhpur) complaints received through telephone or in person, identification and rectification of defects by bringing down the fittings on ground or in position including replacement of drivers, Surge Protection Device (SPD), GI Socket, replacement of old unserviceable light fittings, cleaning of glass/acrylic cover for clear reflection of light, jumper fixing, tightening of loose connections, GI bracket tightening, checking the connection of FRP junction box, light alignment, tightening of flood light safety chain in Hangers, properly incsulating the connections complete all as specified & directed by the Engineer-in-Charge. Note :- (i) Replacement of unserviceable items shall be measured and paid for seperately as 'Supply only' under respective items of schedule 'A'/BoQ . (ii) contractor shall provide/depute sufficient number of electricians and helpers (as directed by Engineer-in-charge) to attend the complaints and rectified the same within 04 hours of receipt of complaints. (iii) contractor manpower shall attend daily to recieve complaints at complaint cell at 9.00 AM from JE E/M and report after completion of complaints and handover a complaint slip to JE E/M with user signature as a record of attending the complaints for payment purposes. (iv) Vehicle, ladder, tools, LT tapes and takes as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement. (v) Any complaint/job given on a particular day shall be repaired/rectified within four hours on the same day. The rate of recovery against non attending/completing job on same day shall be Rs. 75/- per complaint per day. (vi) Old retrieved material shall be deposited in AGE E/M yard and shall be given to contractor after completion of contract.
Supply only electric driver for 75 watt LED type fitting complete all as specified and directed by the Engineer-in-Charge.
Supply only electric driver for 100 watt LED type fitting complete all as specified and directed by the Engineer-in-Charge.
Supply only electric driver for 150 watt LED type fitting complete all as specified and directed by the Engineer-in-Charge.
Supply only surge protection device rated 5kv for LED type fitting complete all as specified and directed by the Engineer-in-Charge.
Attending day to day street / security light (Sodium vapour, MH high bay light, MH hanger flood light of any make, installed at Dispersal & High mast light poles, Sun Shelter lights, Hanger lights, perimeter lights, watch tower lights etc at AF station jodhpur) complaints received through telephone or in person, identification and rectification of defects by bringing down the fittings on ground or in position including replacement of flexible wire, MH choke, MH/Sodium lamp, ignitor, lamp holder, replacement of old unserviceable street light fittings, cleaning of glass/acrylic cover for clear reflection of light, jumper fixing, tightening of loose connections, GI bracket tightening, checking the connection of FRP junction box, light alignment, tightening of flood light safety chain in Hangers, properly incsulating the connections complete all as specified & directed by the Engineer-in-Charge. Note :- (i) Replacement of unserviceable items shall be measured and paid for seperately as 'Supply only' under respective items of schedule 'A'/BoQ . (ii) contractor shall provide/depute sufficient number of electricians and helpers (as directed by Engineer-in-charge) to attend the complaints and rectified the same within 04 hours of receipt of complaints. (iii) contractor manpower shall attend daily to recieve complaints at complaint cell at 9.00 AM from JE E/M and report after completion of complaints and handover a complaint slip to JE E/M with user signature as a record of attending the complaints for payment purposes. (iv) Vehicle, ladder, tools, LT tapes and takes as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement. (v) Any complaint/job given on a particular day shall be repaired/rectified within four hours on the same day. The rate of recovery against non attending/completing job on same day shall be Rs. 75/- per complaint per day. (vi) Old retrieved material shall be deposited in AGE E/M yard and shall be given to contractor after completion of contract.
Supply only lamp holder suitable for HPSV/MH street light fittings of 1 x 70/150/250/400 watt complete all as specified and directed by the Engineer-in-Charge.
Supply only Metal Halide Choke capacity 150 watt complete all as specified and directed by the Engineer-in-Charge. Make- Phillips, Wipro, Crompton Greaves
Supply only Metal Halide Choke capacity 250 watt complete all as specified and directed by the Engineer-in-Charge.
Supply only Metal Halide Choke capacity 400 watt complete all as specified and directed by the Engineer-in-Charge. Make- Phillips, Wipro, Crompton Greaves
Supply only Metal Halide Choke capacity 1000 watt complete all as specified and directed by the Engineer-in-Charge. Make- Phillips, Wipro, Crompton Greaves
Supply only Metal Halide /Sodium Vapour lamp capacity 150 watt complete all as specified and directed by the Engineer-in-Charge.
Supply only Metal Halide /Sodium Vapour lamp capacity 250 watt complete all as specified and directed by the Engineer-in-Charge.
Supply only Metal Halide /Sodium Vapour lamp capacity 400 watt complete all as specified and directed by the Engineer-in-Charge.
Supply only Metal Halide /Sodium Vapour lamp capacity 1000 watt complete all as specified and directed by the Engineer-in-Charge.
Material and labour for prepration of the PCC/RCC poles (single pole structure) upto two meter height from the ground level and apply two coats of cement painting to PCC/RCC poles (single pole structure) upto two meter height from ground level , including painting to cross arm chanel on the top of poles with alluminium paint , and writing the pole number on each pole with reflector type paint complete all as specified and directed by the Engineer-in-Charge.
Material and labour for prepration of the Steel poles (single pole structure) upto two meter height from the ground level and apply two coats of Aluminium Paint Steel poles (single pole structure) upto two meter height from the ground level , and writing the pole number on each pole with reflector type paint complete all as specified and directed by the Engineer-in-Charge.
Achal Sales
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .