Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | ₹13.8 L | L1 | Accepted-Finance Accepted |
| 2 | L2₹16.0 L+₹2.2 L (15.9%)Rejected-Finance | ₹16.0 L+₹2.2 L (15.9%) | L2 | Rejected-Finance Rejected due to bidder is not L1 |
Tender Value
Refer Docs
EMD Value
₹27,200
Closing Date
27 Jan 2021, 6:00 pmClosed
Sh K A Vardhan, IDSE
Office of the GE (Army) Camp Hanuman, Ahmedabad - 380 004
SPECIAL REPAIR / REPLACEMENT OF UNSERVICEABLE LT UG CABLE, JUNCTION BOXES OF SECURITY POLES AND CERTAIN MINOR WORKS UNDER GE (A) AHMEDABAD
2021_MES_410100_1
8151/E8
Open Tender
Civil Works
Item Rate
180 days
GE (Army) Ahmedabad
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (Army) Ahmedabad
₹27,200
Yes
1 Feb 2021
6 Jan 2021
29 Jan 2021
6 Jan 2021
27 Jan 2021
13 Jan 2021
6 Jan 2021 - 13 Jan 2021
Amount
Supplying, laying and testing of LT UG cable, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes complete all as specified and directed. Note: Earth work ( Excavation, Returning & filling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Sch 'A'.
120 sqmm 3.5 core.
25 sqmm 4 core
16 sqmm 4 core
10 sqmm 4 core
10 sqmm 2 core
6 sqmm 2 core
Excavation in trenches in soft/loose soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,Foundation filling of poles or stays complete all as specified and directed.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.
Supply and laying sub class 'B' bricks of old size (230x115x75 mm) or of size locally available , laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
Steel tubes ISI marked light grade galvanised with all fittings fixed to walls / poles as required of following sizes:-.
40 mm bore
80 mm bore
S&F PVC insulated & sheathed, multistranded copper conductor industrial cable 1.5 sqmm 3 core 1100 volt grade from Junction box to street light fitting as required complete all as specified and directed by Engr-in-Charge.
Supply and fix Polystyrene body IP 65 cable junction box with connector metric knockouts on all sides for cable entry including cable glands,sizeof junction box 200 x 160 x 98 mm as per Hensel cat ref no. K 9255 or equivalent duly fitted with followings:-
ELMEX or equivalent make end plate - 1 No
ELMEX or equivalent make end clamps - 2 Nos
Clamp made of 30x5 mm flat iron duly painted with two coats of aluminium paint over a coat of red oxide primer suitable for steel tubular swaged pole type 410 SP-31.
Taking out of unserviceable LT cable XLPE, aluminium armoured type up to 25 Sqmm 4 core from existingcomplete all as directed by Engr-In-Charge.
Taking out of unserviceable LT cable XLPE, aluminium armoured type 35 Sqmm3.5 core to 120Sqmm 3.5 Core core from existing complete all as directed by Engr-In-Charge.
Labour & tools for horizontal boring through road / path / floor for passing UG cables by using trench less technology for laying upto 80mm dia GI pipe complete all as specified and directed. Note : GI pipe will be measured and paid seperately.
M & L for excavation in post holes (or similar holes) n.exc 0.5 cum on plan and getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance 50m.
Surface excavation not exceeding 30 cm deep and averaging 24 cm deep and getting out in soft/ loose soil& removing excavated material to a distance not exceeding 50 m complete all as specified and directed by Engr-in-Charge
M&L for Plain cement concrete 1:4:8 type D2 (using 40mm graded aggregate) as in foundation complete all as specified and directed.
M&L for cement concrete 1:3:6 type C2 (using 40mm graded aggregate) in foundation filling & mass concrete as in post complete all as specified and directed
M&L for Hard core broken boulder of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick watered and well rammed to a line surface complete all as specified and directed.
S & F joist, channel, angle, or T-sections fixed independently, without connecting plates etc (cut to ordinary lengths i.e within 20mm of the length) conforming to FE-290(Gde E-165) complete all as specified and directed
S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, fixed with self tapping screws complete all as specified and directed
M & L brick work with sub class 'B' bricks old size straight or curved on plan exc. 6 mtr mean radius built in cement mortar 1:6 , complete all as specified and directed.
M&L for 75 mm thick cement concrete 1:3:6 type C-2,(40mm graded agg) as in Sub-base to floor finishes complete all as specified and directed.
M&L for 40 mm thick cement concrete (1:2:4), type B1 (using 20mm graded agg) as in flooring finished even and smooth using extra cement complete all as specified and directed.
M&L for 15 mm thick rendering on (external) other than fair faces of brick/concrete surfaces in CM (1:4) finished even and smooth without using extra cement complete all as specified and directed. Mixed with integral WPC (WPC shall be measured and paid separately)
Supply only integral water proofing compound(WPC) Conforming to IS and as approved complete all as specified and directed.
M&L for preparation of new or previously untreated steel or iron surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed.
Preparing newly plastered or concrete surfaces of wall and applying two coats of cement based paint over a coat of white wash complete all as specified and directed.
M & L 75 mm Thick Cement concrete 1:4:8 type D2 (40mm graded aggregate) as in subbase complete all as specified and directed.
M & L 25 mm thick Cement concrete type B-0, (1:2:4) (12.5 mm graded aggregate) complete all as specified and directed.
M & L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Flat) complete all as specified and directed.
M & L for Reinforced cement concrte (1:2:4) type B1 (20mm graded aggregte) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M & L for RCC 1:2:4 type B1 in lintels bands upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded for chamfered angles and throating complete all as specified and directed.
M&L for mild stel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking bending spirally for hooping for coloumns, hooking ends and binding with and including mild steel wire not less than 0.9mm dia or seuring with clips complete all as specified and directed.
All as per item No 33 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed
M & L 10mm thick Screed bed or bedding layer of mortar CM(1:3) Mixed with integral WPC complete all as specified and directed (WPC shall be measured and paid separately)
M&L for 15 mm thick rendering on (internal) fair faces of brick work/concrete surfaces in CM (1:6) finished even and smoth without using extra Cement complete all as specified and directed.
M&L for 10 mmthick rendering on ceiling of concrete surfaces in CM (1:3) finished even and fair without using extra cement complete all as specified and directed.
M&L for preparation of new surfaces of wall and applying three coat of colour wash complete all as specified and directed.
M&L for preparation of new surfaces of ceiling and applying three coat of white wash complete all as specified and directed.
M&L for cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate 75mm thick as in plinth protection including necessary form work and finishing surface even and smooth w/o using extra cement including bitumen joints complete complete all as specified and directed.
M&L for prepolished machine cut Kota stone slab 18 to 22 mm thick as in floors jointed with grey cement slurry incl. rubbing and polishing complete all as specified and directed.
M & L for screed bed or bedding layer of mortar (1:6) 20mm thick as laying in floor finishes complete all as specified and directed.
M & L for 40 mm thick Damp proof course in cement concrete (1:2:4) type B0 to horizontal or vertical surfaces including water proofing compound necessary formwork complete all as specified and directed.
M&L for providing cement concrete 50mm thick type B1 1:2:4 (20mm graded aggregate) as in floor complete all as specified and directed
S & F dividing glass strip 3 mm thick and 22 mm width complete all as specified and directed
S&F mild steel angles as in columns, posts, purlins rafters beams gusset plate and struts including embedding in concrete, and welding etc complete all as specified Fe-410-W Gde-E-250 quality A
M&L for 15 mm thick rendering on (external) other fair faces of brick/concrete surfaces in CM (1:4) finished even and smooth without using extra cement complete all as specified and directed.
M&L PCC (1:2:4) type B-0 using 12.5 mm gradedcrushed stone aggregate as in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directing complete all as specified and directed
S&F pre-painted galvalume aluminium zinc coating corrugated steel sheet 0.60mm thick of any colour (as approved by GE) having tensile strength of 550 Mpa as in roofing, self drilling and self tapping screws of suitable size including neoprene and EPDM washers complete all as specified.
S&F mild steel tubular rectangular sections as in coloums, posts, purlins rafters beams gasset plate and struts including embedding in concrete, and screwing etc complete all as specified Fe-410-W Gde-E-250 quality A
Supply and install split Type indoor/ outdoor air conditioner electric driven single phase cooling capacity 4500K Cal per hour complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor quality with minimium BEE 5 Star rating of capacity 1.5 Ton complete all as specified and as directed. Make : Carrier / Hitachi / O General / Voltas
S&F Single pole and neutral, socket outlet, with 2 pole and earth metal enclosure 20 amp recess mounted with chained metal cover for socket outlet with and including one number single pole 'C' series MCB 20 Amps as required. Make : Legrand cat ref No 607840 & 408590 or equivalent in Hager or Scheider as approved.
Supply and fixing MCB DB Single pole neutral 4 way,240 volts AC ,of sheet metal phosphotised powder coated with 200 Amps,neutral bars ,earth bar all as specified and directed .
Supply and fixing MCB single pole and neutral 240 volts 32 to 40 Amps ,50 Hz 10 KA ,C series all as per specified and directed.
Supply and fixing MCB single pole 240 volts ,6 to 32 Amps ,50 Hz 10KA ,C series all as per specified and directed.
M & L for submain wiring along with the 2 x 6 .0 Sqmm + 1 x 6 Sqmm earth wire FR PVC INSULATED multistranded copper conductor single core cable in surface / recessed in PVC casing caping as reauired at site complete all as specified and as directed. Note:- Three runs & cable shall be measured as one length.
Supply and fix water cooler electric driven (single phase ) having approx storage capacity of 80 litre and normal cooling capacity of 40 litre per hour. Make:- Bluestar Cat ref No SDLX480B/Voltas / Haier as approved.
SNEH TRADERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .