Tender Value
Refer Docs
EMD Value
₹2.5 L
Closing Date
12 Feb 2021, 6:00 pmClosed
HQ Chief Engineer Bareilly Zone
HQ Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan, Station Road Bareilly Cantt Bareilly - 243 001
PROVISION OF TWO UNDER PASSES AT IMA DEHRADUN
2020_MES_401168_2
CEBZ/DDN/T-10 of 2020-21
Open Tender
Civil Works
Lump-sum
180 days
Dehradun
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE IMA DEHRADUN
₹2.5 L
6 Mar 2021
29 Jan 2021
17 Feb 2021
29 Jan 2021
12 Feb 2021
6 Feb 2021
30 Jan 2021 - 4 Feb 2021
Amount
Total amount of SCHEDULE 'A' PART-I (BUILDING WORK) (For details see Schedule 'A' Part-I in PDF folder)
Total amount of SCHEDULE 'A' PART-II (INTERNAL WATER SUPPLY) (For details see Schedule 'A' Part-II in PDF folder)
Total amount of SCHEDULE 'A' PART-III-A (INTERNAL ELECTRIFICATION) (For details see of Schedule 'A' Part-III-A in PDF folder)
SCHEDULE 'A' PART-III-B (INTERNAL ELECTRIFICATION)
M&L for point wiring (concealed) complete using approved colour coding as per IS (Red, Black, Green for single phase circuit) with multi-stranded copper conductor 1.5 Sqmm nominal cross section area, single core PVC insulated unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No. in and including PVC conduit medium grade conduit accessories such as bend, tee, junction boxes elbows etc, ISI marked with valid CML No. (IS :9537 -1983 for conduit and IS :9537 -1976 for conduit accessories) including pressed steel terminal sunken boxes 1.6 mm thickness, 65mm deep with earth dolly, duly painted with two coats of black bitumenous paint over a coat of red oxide primer externally, covered with 3mm thick plastic laminated sheet ISI marked top cover fixed with brass screws, cup washers and PVC unsheathed copper conductor 1.5 Sqmm cross sectional area, single core FRLS cable as earth continuity wire connected to DBs/sunken boxes/fittings conductor and all other metal parts with earth dolly complete all as specified and directed for the following:-
One Light point controlled by one switch 5/6 Amp
One fan/exhaust fan point controlled by one switch 5/6 Amp.
One 5/6 Amp socket point controlled by one switch independent board.
M&L for point wiring (concealed) complete using approved colour coding as per IS (Red, Black, Green for single phase circuit) with multi-stranded copper conductor 2.5 Sqmm nominal cross section area, single core PVC insulated unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No. in and including PVC conduit medium grade conduit accessories such as bend, tee, junction boxes elbows etc, ISI marked with valid CML No. (IS :9537 -1983 for conduit and IS :9537 -1976 for conduit accessories) including pressed steel terminal sunken boxes 1.6 mm thickness, 65mm deep with earth dolly, duly painted with two coats of black bitumenous paint over a coat of red oxide primer externally, covered with 3mm thick plastic laminated sheet ISI marked top cover fixed with brass screws, cup washers and PVC unsheathed copper conductor 2.5 Sqmm cross sectional area, single core FRLS cable as earth continuity wire connected to DBs/sunken boxes/fittings conductor and all other metal parts with earth dolly for one three pin 15/16 Amp, socket outlet point on independent board complete all as specified and directed.
M&L for Distribution board (DB) sheet metal enclosure for mounting MCBs/Isolators/ELCBs etc. factory made conforming to IS: 13032, IP-42 protection, fabricated of CRCA sheet sheet not less than 1.2 mm thick fitted with DIN channel, neutral link and 200 Amps rated bus bar, DB semi glossy finished with epoxy polyster based powder coated paint dust and vermin proof, double door, single pole neutral 8 way with 200 Amps rated copper bus bar neutral, earth bar, 240 volts, flush to wall connection with cable, complete all as specified and directed.
S&F MCB, single pole & neutral, 40 Amps current rating, breaking capacity 10 KA, 240 volts complete all as specifed and directed.
S&F MCB 6 to 32 Amps, single pole, 240 volts, breaking capacity 10 KA with 'B' characteristic complete all as specified and directed.
S&F LED surface and wall mounted fitting LED batten, extryded aluminium housing provided for dissipation with polycorbonate diffuser and integrated electronic driver with industrial grade heavy duty having THD<10% suitable for 20 watt including tube rod light (double side connection) ultra glass LED tube light with high efficiency suitable for installation T8 fitting with G13 lamp holder, high lumen output PF>0.98, neutral white 20 watt 4 ft long light fitting with lamp etc complete with all light accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make-Havells Cat No. ENDURALINEARNEOBS20WLED865SPCWH & CRYSTAL 1213TBDSTL20WLED865SGLASS/ MaKE-C&S Cat Part No.TATRA-Ei/20W/ Make-Crompton Cat No.LCTL-18CDL+LLT8-20
Supply, fixing, connecting & testing ceiling fan 1200 mm sweep, energy saving 5 star rated complete without regulator, 230 volts, single phase, including canopy set down rod and shackle assembly, fan hook and connecting with and including PVC insulated three core copper conductor of size 1.5 Sqmm to ceiling rose to fan and writing MES No with balck synthetic enamel paint 2.0 cm high, complete all as specified and directed.
Supply, fixing, connecting and testing building security light fitting LED 45 watt with pressure die cast aluminium housing heat resistant toughened glass, IP-66 protection and impact resistance of IK07 with 10 KV buit in surge protection device, better optics for uniform distribution complete with electronic driver etc, including connecting up with three core copper conductor cable with 1.5 Sqmm size copper wire from ceiling rose to connector of light fitting complete all as specified and directed. Make-Havells Cat No.ENDURAPEARLNEOSL45WLED757POSYTOPC/ Make-C&S Cat Part No.LTESSI45WLED/LS / Make-Crompton Cat No.LCTP-45CDL
M&L for fabrication of GI pipe, light grade, bracket of size 40 mm dia and 1.50 m long fixed to wall with and including nut, bolts and GI clamps of size 50 x 5 mm as required including two coats of synthetic enameled paint over a coat of primer, complete all as specified and directed.
S&F Exhaust fan 300 mm sweep, energy saving 3 star, 230 volts, single phase, metalic body with louver shutter, bracket etc complete, including cutting the round hole of required size in wall finishing the same supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 23/0.0076 copper cable, rubber insulated from ceiling rose to exhaust fan motor and writing MES No with black synthetic enamel paint 2.0 cm high complete all as specified and directed. Make- Havells Model-Turbo force SP/ Bajaj Model-70046(MAXX AIR)/ Crompton Model-TRANS AIR
M&L for Earthing with galvanized mild steel earth plate (electrode) 600 x600x6.00mm thick, burried directly in ground earth pit not less than 2.25 mtr deep below ground level surrounded with adequate quantity of charcole dust mixed with salt ot a packed thickness of 15 cm all round the plate, using 4 mm dia GI wire as earth wire moulded and riveted to earth plate at one end and connected to main switch/control switch of the building at another end, GI earth wire incased in and including 15 mm dia GI "light grade' pipe from upper end of earth plate upto main switch/control of the building including 20 mm dia gi pipe light grade as water pipe from earth chamber to upper edge of earth plate, CI funnel with wire mesh fixed on water pipe and provision of PCC chamber and RCC pit cover with lifting handle, excavation earthwork including laying of GI pipe concealed in floor/ walls all as described in electrical plate No 5 of SSR Part-I complete all as specified and directed.
Note:- The unit quoted rate deemed to be included for protection pipe and GI earth wire 4 mm dia from top of earth plate to 7.5 mtr above ground level.
S&F 4 mm dia GI wire earth continuity conductor on main earthing lead fixed to pole or burried in ground or any other situation for loop earthing extra as required complete as specified & directed.
Total amount of Sch 'A' Sec - IV (SITE CLEARANCE AND EARTHWORK) (For details see Schedule 'A' Part-IV in PDF folder)
Total amount of SCHEDULE 'A' PART-V(A) (SEWAGE DISPOSAL) (For details see Schedule 'A' Part-V(A) in PDF folder)
SCHEDULE 'A' PART-V(B) (SEWAGE DISPOSAL)
Construction of Soakage well of size 1.20 mtr dia and 3.00 m deep, excavation in any type soil, foundation in PCC 1:3:6 type C2, walls of Honey combed masonary and solid masonry using fly ash bricks in cement mortar 1:4, including RCC cover slab and bands, CI manhole cover and filling with brick bats complete all as shown in TD drawing and specified.
Construction of Septic tank to carry sewage for 10 users, excavation in any type soil, foundation floor in PCC 1:2:4, brick work in CM 1:4 using fly ash bricks, RCC, baffle wall & slab covers including RCC precast manhole covers having 6mm plate embeded all around/reinforced concrete cover with angle iron frame, vent shaft, sludge chamber and connection etc complete all as shown in TD drawing and specified.
Supply & laying DWC HDPE SN-8 pipes 200mm internal dia outer dia conforming to IS:16098 (Part-2) 2013, jointing of pipes by elastomeric rubber rings & couplers etc, laid in trenches and testing, complete all as specified and directed.
Total amount of SCHEDULE 'A' PART-VI(A) (EXTERNAL ELECTRIFICATION) (For details see Schedule 'A' Part-VI(A) in PDF folder)
SCHEDULE 'A' PART-VIB (EXTERNAL ELECTRIFICATION)
Supply, instalation, testing and commissioning LT panel board CPRI approved, of size 140x120x60cm, KIOSK type weather , dust and vermin proof, outdoor double door shutter, made out from CRCA sheet 3.15mm thick outer and 2.00 mm thick for inner door conforming to IS:8623 with angle iron 50mmx50mmx6 mm duly painted with two coat of stove enamel paint over a coat of red oxide primer, floor mounted type closed bus bars, chamber and internal wiring, cable glands, cable lugs etc and provision of PCC 1:2:4 type B1 in platform/plinth upto height 30 cm from ground level and bottom of panel shall be minimum 15 cm above platform on angle iron legs grouted in plinth, complete all as specified and directed having following incoming and outgoing feeder control :-
(a) INCOMING:- MCCB 400 Amp 4 pole, 415 Volts, with breaking capacity 50 KA - 01 No.(Main incoming) (b) ACCESSORIES :- (i) Aluminium Bus bar 630 Amp rating three phases 4 wire system - 04 Nos. (ii) Digital multi function panel mounted meter for energy metering, monitoring and management system suitable for LT 3 phase 4 wire applications, using micro controllersand non voltage memory and providing anti tamper features and communication facility at high accuracy with accuracy for active energy as per IS:13779-99/IEC 61036, CL 1.0, operating temperature - 10 to +55 degree C, relative humidity 95% non condensing, 96x96x86 mm or nearer size, 3 line backlit display of 6 digit each to display voltage , current active power, reactive power, apparent power, power factor frequency and other parameters, digit height 8x4.8 mm, protection index IP-54 with all necessary CT 0-400 Amps & PT 0-500 volts and instrument fuses, wiring complete - 01 Set (iii) Panel indicator lamp for three phase R, Y & B for each incoming and outgoing feeder - 01 Set (iv) Complete control panel internal wiring including making connection all incoming and out going MCB/MCCBs with suitable size of stranded copper conductor -01 job
(c) OUTGOING:- (i) MCCB 250 Amp 4 pole, 415 Volts, with breaking capacity 35/36 KA - 02 Nos. (ii) MCCB 200 Amp 4 pole, 415 Volts with breaking capacity 35/36 KA - 02 Nos (iii) MCCB 63 Amp 4 pole, 415 Volts with breaking capacity 16 KA - 01 Nos
Material and labour for earthing wth galvanised cast earth plateof size 600x600x6mm thick burried vertically in ground to a depth not less than 2.25mtr below GL with top edge of earth plate not less than 1.5mtr below GL the earth plate surrounded by adequate quantity of charcoal dust and salt all around earth plate 15 cm and earth plate connected with GI strip 32X6 mm as earth continuity lead with nut, bolts or rivetted to earth plate one end, protection with GI pipe light grade 40 mm bore, GI pipe medium grade 15 mm bore watering pipe from earth chamber to earth plate, CI funnel with wiremesh fixed on water pipe and PCC 1:2:4 type B-1 using 20mm graded stone aggregate in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1 duly reinforced with MS bar 6mm dia @150 mm both ways and 10mm dia MS bar in lifting handle, including necessary excavation & earthwork etc all as shown in electirical plate No 3 of SSR Part-I and complete all as specified and directed. (Note:-On testing after completion if desired earth resistance does not obtain, the earthing shall be redone by contractor without any extra cost to Govt).
Supply, laying and jointing LT XLPE Insulated, galvanized steel strip or wire armoured power electric cable (heavy duty) 1100 volt grade with aluminium stranded conductor of size 400 Sqmm x 3.5 core confirming to IS 7098 (Part-I) of 1988 passing through pipes, in duct, on poles, in trenches, under road etc complete all as specified and directed.
Supply, laying and jointing LT XLPE Insulated, galvanized steel strip or wire armoured power electric cable (heavy duty) 1100 volt grade with aluminium stranded conductor of size 300 Sqmm x 3.5 core confirming to IS 7098 (Part-I) of 1988 passing through pipes, in duct, on poles, in trenches, under road etc complete all as specified and directed.
Supply, laying and jointing LT XLPE Insulated, galvanized steel strip or wire armoured power electric cable (heavy duty) 1100 volt grade with aluminium stranded conductor of size 185 Sqmm x 3.5 core confirming to IS 7098 (Part-I) of 1988 passing through pipes, in duct, on poles, in trenches, under road etc complete all as specified and directed.
Supply, laying and jointing LT XLPE Insulated, galvanized steel strip or wire armoured power electric cable (heavy duty) 1100 volt grade with aluminium stranded conductor of size 150 Sqmm x 3.5 core confirming to IS 7098 (Part-I) of 1988 passing through pipes, in duct, on poles, in trenches, under road etc complete all as specified and directed.
Supply, laying and jointing LT XLPE Insulated, galvanized steel strip or wire armoured power electric cable (heavy duty) 1100 volt grade with aluminium stranded conductor of size 120 Sqmm x 3.5 core confirming to IS 7098 (Part-I) of 1988 passing through pipes, in duct, on poles, in trenches, under road etc complete all as specified and directed.
Supply, laying and jointing LT XLPE Insulated, galvanized steel strip or wire armoured power electric cable (heavy duty) 1100 volt grade with aluminium stranded conductor of size 10 Sqmm x 2 core confirming to IS 7098 (Part-I) of 1988 passing through pipes, in duct, on poles, in trenches, under road etc complete all as specified and directed.
Taking out LT under ground cable of size 300 to 400 Sqmm, 3.5 core from trenches/passing through pipe/on poles etc complete all as specified and directed. (Note:- Excavation, earth work shall be measured paid separately under respective items)
Taking out LT under ground cable of size 95 to 185 Sqmm, 3.5 core from trenches/passing through pipe/on poles etc complete all as specified and directed. (Note:- Excavation, earth work shall be measured paid separately under respective items)
Taking out LT under ground cable of size 6 Sqmm, 2 core from trenches/passing through pipe/on poles etc complete all as specified and directed. (Note:- Excavation, earth work shall be measured paid separately under respective items)
Taking out HT under ground cable of size 120 to 150 Sqmm, 3 core from trenches/passing through pipe/on poles etc complete all as specified and directed. (Note:- Excavation, earth work shall be measured paid separately under respective items)
Supply and fixing earth continuity conductor or main earthing lead 36x6 mm galvanised iron strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and directed.
M&L for boring of holes under road / hardstanding by trenchless technology including HDPE pipes of 150mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed.
Total amount of SCHEDULE 'A' PART-VIIA (EXTERNAL WATER SUPPLY) (For details see Schedule 'A' Part-VIIA in PDF folder)
SCHEDULE 'A' PART-VIIB (EXTERNAL WATER SUPPLY)
Drilling and tapping from 150mm dia cast iron water mains (in position) including saddle piece made out of mild steel flat iron of size 50x6mm duly welded with 40mm dia GI socket and 02 Nos nut bolts of suitable size /length, necessary rubber packing for branch connections for the internal dia 20mm, complete all as specified and directed at site.
Drilling and tapping from 100mm dia cast iron water mains (in position) including saddle piece made out of mild steel flat iron of size 50x6mm duly welded with 40mm dia GI socket and 02 Nos nut bolts of suitable size /length, necessary rubber packing for branch connections for the internal dia 20mm, complete all as specified and directed at site.
Boring of holes 150 mm dia under road / pavement/ hardstanding by trenchless technology using ultrasound technique and necessary machines complete all as specified and directed.
M&L for construction of brick masonry valve pit of following internally size 900mm x 900mm x 900mm with angle iron 25mm x 25mm x 4mm frame and 2mm thick mild steel plate cover painted with two coats of synthetic enameled paint over a coat of red oxide primer after preparation of surface including locking arrangement, including necessary excavation and earth work 75 mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate over 100 mm thick hard core using broken in foundation/base floor, brick work in cement mortar (1:6) in one brick thick wall and 15mm thick cement plaster in cement mortar 1:4 on internal surface of walls and outside upto 150 mm deep below ground level complete all as specified and directed at site.
Dismantling of old existing brick masonry valve pit chamber and M&L for construction of brick masonry valve pit internally size 1200mm x 1200mm x 1200mm with angle iron 25mm x 25mm x 4mm frame and 2 mm thick mild steel plate cover, painted with two coats of synthetic enameled paint over a coat of red oxide primer after preparation of surface including locking arrangement and necessary excavation and earth work 75 mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate over 100 mm thick hard core using broken in foundation/base floor, brick work in cement mortar 1:6 in one thick wall and 15mm thick cement plaster in cement mortar 1:4 on internal surfaces of walls and outside upto 150 mm deep below ground level complete all as specified and directed at site.
S&F cast iron non raising type sluice valve for 100 mm bore pipe with drilled flanged ends, stainless steel spindle with gun metal working parts with hand wheel pressure type PN 1.0 including disconnectionh and removing the unserviceable sluice valves from the existing pipe line/ valve chamber complete all as specified and directed
S&F cast iron non raising type sluice valve for 150 mm bore pipe with drilled flanged ends, stainless steel spindle with gun metal working parts with hand wheel pressure type PN 1.0 including disconnectionh and removing the unserviceable sluice valves from the existing pipe line/ valve chamber complete all as specified and directed
S&F cast iron non raising type sluice valve for 200 mm bore pipe with drilled flanged ends, stainless steel spindle with gun metal working parts with hand wheel pressure type PN 1.0 including disconnectionh and removing the unserviceable sluice valves from the existing pipe line/ valve chamber complete all as specified and directed.
Cutting of roads/ hardstanding for laying of GI/CI pipes at required depth not exc 1.5 m complete all as specified and directed.
M&L for laying DI pipe 100 mm bore spigot and socket ends, class K-7 with rubber gasket laid in trenches, cut to length to match existing fitting / pipes or insertion of new DI specials complete all as specified and directed.
M&L for laying DI pipe 150 mm bore spigot and socket ends, class K-7 with rubber gasket laid in trenches, cut to length to match existing fitting / pipes or insertion of new DI specials complete all as specified and directed.
M&L for laying DI pipe 200 mm bore spigot and socket ends, class K-7 with rubber gasket laid in trenches, cut to length to match existing fitting / pipes or insertion of new DI specials complete all as specified and directed.
Total amount of SCHEDULE 'A' PART-VIII (DEMOLITION / DISMANTLING) (For details see Schedule 'A' Part-VIII in PDF folder)
Note: Tenderers may be noted that amount of credit Rs. 1150537.66 will be deducted from the total amount arrived, at the time of acceptance of contract. (For details please refer Schedule of credit).
Sanjeev Construction Co
Sham Sunder Bansal
Laxmi Builders
RAMAPATI ENGINEERING SERVICES
R.K Engineering Assemble
Ms Banco Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .