Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-AOC H NO 107 A RAJENDRA NAGAR DIGARI KALAN JODHPUR 342015 | JODHPUR | JODHPUR | RAJASTHAN | 342015 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹40.6 L+₹44,250 (1.10%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹43.9 L+₹3.7 L (9.27%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹44.1 L+₹3.9 L (9.76%)Rejected-Finance HOUSE NO 8 589 BEHIND PHC HOSPITAL OLD BUS STAND KORBA KORBA CHHATTISGARH 495678 | 495678 | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹45.5 L+₹5.3 L (13.3%)Rejected-Finance 0 BEECHPARA DANGAURA MAHENDRAGARH MANENDRAGARH CHIRMIRI BHARATPUR CHHATTISGARH 497442 | KOREA | CHHATTISGARH | 497442 | L5 | Rejected-Finance Rejected being L5 |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
31 Jan 2022, 6:00 pmClosed
GE ARMY CENTRAL IN ARMY AREA JODHPUR
GE ARMY CENTRAL IN ARMY AREA JODHPUR
SPECIAL REPAIRS TO ROOF TREATMENT FALSE CEILING PLATSER WK AND FLOOR TILES IN BLDG NO P 1 AND P 2 AT KURC II IN THE AREA OF AGE B R I UNDER GE ARMY CENTRAL IN ARMY AREA JODHPUR
2021_MES_498329_1
GE/J/A- OF 2021-22 (9068/E8)
Open Tender
Civil Works
Item Rate
180 days
GE ARMY CENTRAL IN ARMY AREA JODHPUR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE ARMY CENTRAL JODHPUR
₹94,000
23 Feb 2022
30 Dec 2021
2 Feb 2022
30 Dec 2021
31 Jan 2022
6 Jan 2022
Amount
(B/R WORK) Demolition of cement concrete of thickness n. exc 200 mm and in any position including removal of existing water proofing treatment of any description and bedding in any type of roof and removing rubbish to a distance exc 50 M but not exc. 250 M, complete all as specified and as directed.
Plain cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, complete all as specified & directed.
M&L for 75mm thick Plain cement concrete 1:3:6 type C1 (using 20mm graded crushed stone aggregate), as in plinth protection including necessary form work laid in alternate bays and filling the joints with bitumen mastic filler, complete all as specified and directed.
M&L Factory made machine pressed precast conctete interlocking paver block, size 60 mm thick with 6mm top layer of anti abrassive rubberised material & any shape, rubberised finish confirming to IS 15658-2006, M-35 Grade, with grey cement and pigments, over and including sand cushioning of 25mm thick, complete all as specified and as directed.
M&L machine pressed precast cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in kerb stone blocks of approved size and setting in cement mortar 1:4, complete all as specified and as directed .
Demolition of stone / boulder masonry walling built in cement mortar including all quoins arches pillars etc and removal unserviceable materials, debris, rubbish to out side MD land, complete all as specified and as directed.
Cutting into old masonry to form toothings for and bonding in new brick or stone work including making good but making good in lime or cement mortar of the same mix as for new walling, complete all as specified and as directed.
M&L for squared rubble walling, Jodhpur type, regular coursed , well bonded, bedded and solidly hearted, built in cement mortar 1:6, complete all as specified and as directed.
Ditto all as per item no. 8.00 here-in-above, but except stone.
M&L precast cement concrete 1:2:4 type C-1 using 20mm graded stone aggregate as in solid block masonry exceeding 10cm width and setting in cement mortar 1:6 complete all as specified and as directed .
Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exceeding 20mm & dressing face beds and joints as specified to square rubble walling un-coursed or brought up to courses, complete all as specified & as directed by Engineer-in-charge.
Dismantling of floor / wall tiling of any description including cement mortar bedding / backing coat and removing rubbish to out side MD Land complete all as specified and as directed.
M&L 25mm thick (average) PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate), as in sub base , the surface of concrete is to be finished even & rough to receive tile flooring surface, with out using extra cement complete all as specified and as directed.
M&L non skid ceramic tiles (premium quality), coloured, of size exceeding 0.18 Sq.m and not exceeding 0.38 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6, complete all as specified and as directed.Makes:- Kajaria / Somani / Orient bell.
M&L non skid ceramic tiles (premium quality), coloured, of size exceeding 0.18 Sq.m and not exceeding 0.38 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in dado / verticle surface, etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles including screed bed or bedding layer of mortar 10 mm thick in cement mortar 1:4, complete all as specified and as directed.Makes:- Kajariya / Somani / Orient bell.
Dismantling of stone slab / floor / wall tiling of any description including cement mortar bedding / backing coat and removing rubbish to out side MD Land complete all as specified and as directed.
Dismantling of stone sett of any description, laid in dry and removing rubbish to out side MD Land complete all as specified and as directed.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off the premises, complete all as specified and as directed.
Racking out joints/ pointing to random rubble or polygonal rubble un-coursed or brought up to courses masonry built in cement mortar or cement lime mortar, coursed or un-coursed in walls not less than 12mm deep, washing the joints, removing rubbish off the premises and keeping the surface to pointed or plastered wet for two days prior to re-pointing or plastering, complete all as specified & directed by Engineer-in-charge.
M&L 15 mm thick, plastering in CM 1:6 on stone masonry surfaces ( internal wall surfces) finished even and smooth with out using extra cement, complete all as specified and as directed.
M&L 15 mm thick, plastering in CM 1:4 on stone masonry surfaces finished even and smooth with out using extra cement using integral water proofing liquid as per manufracturer, complete all as specified and as directed.
M&L plastering 5 mm thick in CM 1:3 on concrete surfaces of ceiling / facia / chajja, finished even and smooth without using extra cement complete all as specified and as directed.
M&L plastering 10 mm thick in CM 1:3 on concrete surfaces of ceiling , finished even and smooth without using extra cement complete all as specified and as directed.
M&L for keyed pointing in CM 1:3 to square rubble stone masonry jodhpur type wall surfaces, uncoursed or brought up to courses complete all as specified and as directed.
Preparing new plastered or unplastered surfaces and applying (3mm thick in two layers) Birla/JK wall care putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of oil bound distemper over one coat of primer on walls, complete all as specified and as directed.
Complete removal of existing treatment of any description on walls and applying with wall care putty 3mm thick in two layers including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of oil bound distemper over one coat of primer on walls complete all as specified and as directed.
Preparation of new plastered or unplastered surfaces and applying three coats of white wash on wall surfaces, complete all as specified and as directed.
Preparation of old plastered surfaces and applying one coat of white wash on ceiling surfaces, complete all as specified and as directed.
Preparation of old white washed surfaces and applying one coat of white wash on wall surfaces, complete all as specified and as directed.
Preparation of new plastered or un-plastered surfaces of walls and applying two coats of cement base paint incld & over one coat of primer, complete all as specified and as directed.
Preparation of old painted external surfaces of walls and applying one coat of cement base paint, complete all as specified and as directed.
Preparation of new or previously untreated wood and wood based surfaces of any description otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed .
Preparation of new or previously untreated steel surface of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red- oxide, zinc chrome primer complete all as specified and as directed.
Taking down chowkats or frames (without taking of shutters from the frames) area not exceeding 1.5 Sqm each complete all as specified and as directed.
Taking down chowkats or frames (without taking of shutters from the frames) area exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and as directed .
Taking down Shutters of any description exceeding 1.00 Sq.m and not exceeding 2.00 Sq.m each after easing and adjusting complete all as specified and as directed.
Taking down Shutters of any description and refixing the shutters in the same opening of any description exceeding 1.00 Sq.m and not exceeding 2.00 Sq.m each after easing and adjusting complete all as specified and as directed.
M&L mild steel work as in door frame and similar work fixed with angle cleates, confirming to Fe 290 Grade - E - 165 complete all as specified and as directed.
M&L rolled mild steel sections like angle, channel, flat, square etc as in framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars ,barred iron doors; ladders ;framed balusters walk ways railings framed work of water tanks and similar work confirming to Fe-290Gde E-165 complete all as specified and as directed.
M&L rolled mild steel sections like hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; and similar work confirming to Fe-290Gde E-165 complete all as specified and as directed.
M&L factory Made modular shutters, 35 mm thick solid core with particle board core construction, both side laminated, as per IS 2202(part-I, 1999) . The stiles & rails shall be with out any joint and made with non- coniferous timber hard wood (Hillock/ Mirantee/ Bosum/ Benteak) with moisture content not less than 12% as per IS. The face panel comprising of ply wood or cross band and face veneers shall be glued by hot pressed process. The over all finished thickness of face panel shall not be less than 35mm while the thickness face veneer shall not be less than 0.6 mm complete all as specified and directed.
Taking down steel windows and ventilators ( glazed / fly proof) of any description, complete all as specified and as directed.
S&F Factory made steel window with side hung shutters including box type hinges, steel peg stay, glazed window, complete all as specified and as directed.
S&F Factory made steel window with side hung shutters including box type hinges, steel peg stay, gauged window, complete all as specified and as directed.
S&F Factory made steel ventilators with top hung shutters including box type hinges, steel peg stay, glazed ventilator, complete all as specified and as directed.
S&F Factory made steel ventilators with top hung shutters including box type hinges, steel peg stay, gauged ventilator, complete all as specified and as directed.
S&F 200mm size aluminium anodised barrel tower bolts of extruded section, complete all as specified and as directed.
S&F 150 mm size extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and directed.
S&F 300 mm length aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, complete all as specified and as directed .
S&F SS butt hinge of size 100mm , medium weight, complete all as specified and as directed.
S&F 140 mm floor door stopper of aluminium alloy body and tongue , anodised ,with hard drawn steel spring ,fixed in floor, complete all as specified and directed.
S&F 4.00 mm thick figured glass,pin head type and glazing with putty in square not exceeding 0.50 Sqm in each pane, complete all as specified and as directed.
S&F Sheet glass 3mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sq.m in each pane complete all as specified and as directed.
S&F GI wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed to Al door/window, complete all as specified and as directed.
S&F in repair GI wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.00 mm and fixed to Al door/window, complete all as specified and as directed.
M&L PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in hold fast block concrete, complete all as specified and as directed.
M&L flat iron as in hold fast for door frame and similar work fixed with angle cleates, confirming to Fe 290 Grade - E - 165 complete all as specified and as directed.
Demolition of reinforced cement concrete such as roof, floor slab, beams, stair case, landing, chajjas and similar suspended work and removing rubbish to out side MD land complete all as specified and as directed.
M&L reinforced cement concrete type B-1 [Nominal Mix] 1:2:4 using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
S&F 5 cm thick sand stone slabs Jodhpur pattern/colour in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc not exceeding 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar (1:4) complete all as specified & directed by Engineer-in-charge.
Supply only water proofing compound complete all as specified & directed by Engineer-in-Charge
Use and waste formwork to sides & soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick [horizontal or sloping] including rough finished surfaces complete all as specified and directed.
Use and waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide includingrough finished surfaces complete all as specified and directed.
Use and waste of form work to sides and soffits of lintels, beams, brackets, shelves and similar works for rough finished surfaces of concrete complete all as specified and as directed.
RCC M-25 design mix as in slabs supported on walls, beams and colunms in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
RCC 1:1½:3 type A1 by using 20mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span including necessary form work complete all as specified and directed.
M&L TMT steel bars of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
M&L TMT steel bars of 6 to 8 mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
TMT steel bars of 5mm to 10mm dia bars as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
M& L for carrying out of water proofing treatment in roof to the following stages : (a)- M & L 10 mm thick sceeding in cement mortar 1:3 on brick work or concrete surfaces on roof surfaces mixed with WPC, surface finished even and smooth without using extra. (b)- Apply first coat of bitumen primer confirming to IS 3384-1986 @ 0.40Kg/Sqm. (c)- Second coat of bonding material using hot blown type bitumen confirming to IS- 702-1988 grade 85/25 @1.20 Kg/ Sqm (d) Third layer of 3 mm thick APP modified polymeric membrane with non-woven polyester reinforcement shall be laid by torch application method. The side overlaps of minimum 75 mm and the end laps of minimum 100 mm. All overlaps & joints shall be sealed as per manufacturer's instructions. (e) Fourth coat of bonding material using hot blown type bitumen confirming to IS 702-1998 of grade 85/25 @ 1.20 Kg/Sqm (f) Fifth and top most layer of surface finish 25mm thick PCC 1:2:4 type B-1 using 12.5mm graded crushed stone aggregate in roof padding over APP membrane, the surface of concrete is to be finished even and smooth with using extra cement and proved V shaped groove 6mm wide & 10mm depth filled with mastic bitumen of (1:1) complete all as specified and directed by Engr-in-charge.
GI frame work size of grid 605 x 605mm for seamless ceiling comprising of GI perimeter chanel 0.55mm thick with two unequal flanges of 20 & 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm c/c intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm c/c with GI cleat and steel expansion fasteners with and inccluding ceiling section (not exceeding 1.2M length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to intermediate channel at 457mm c/c and hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and including providing gypsum board 12mm thick in ceiling fixed with screws as per manufacturers instructions over the frame work and preparation of ceiling board and applying two coats of oil bound distemper over a coat of 'Birla' wall / ceiling care putty including dismantling of existing false ceiling of any thickness with cover fillets complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide but not exceeding 1.5m in deep for foundation etc and not exceeding 1.50m deep for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and as directed.
Removing of excavated material to a distance not exceeding 50m and deposited where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
(E/M WORK) Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc . removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed.
Point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multi stranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including heavy duty drawn through and including in 20mm dia PVC concealed conduit with all accessories complete concealed in wall/roof/floor etc, ISI marked with modular metal modular box of suitable size for mounting of modular switches, sockets and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly for,one way switch One light / fan / bell point controlled by one, one way switch, complete all as specified and directed .
All as per Serial Item No. 76 above but one 3/5 pin socket outlet 5/6 Amps on independent board, complete all as specified and as directed.
All as per Serial Item No.76 above but for one 3/5 pin socket outlet 5/6 Amps on the same board with other switches, complete all as specified and as directed.
All as per serial Item No.76 above but for 15 Amps 5/6 pin socket point on independent board with 2.50 Sqmm PVC insulated FRLS multi-stranded copper conductor with 2.50 Sqmm PVC insulated FRLS multi-stranded copper conductor as earth wire, complete all as specified and directed .
All as per serial Item No.76 above but for 15 Amps 5/6 pin socket point on independent board with 4.00 Sqmm PVC insulated FRLS multi-stranded copper conductor with 4.00 Sqmm PVC insulated FRLS multi-stranded copper conductor as earth wire, complete all as specified and directed .
M&L switch piano, modular type, single pole, one way, 5/6 Amps, 230 Volts complete all as specified and as directed. Make: Legrand / L&T / Schneider
M&L switch piano, modular type, single pole, one way, 16 Amps, 230 Volts complete all as specified and as directed. Make: Legrand / L&T / Schneider
M&L socket outlet 5 Amps 2-in-1, 3/5 pin 230V AC modular type, complete all as specified and directed. Make: Legrand / L&T / Schneider
M&L socket outlet 6/16 Amps 2-in-1, 3/5 pin 230V AC modular type, complete all as specified and directed. Make: Legrand / L&T / Schneider
S&F batten lamp holder,metal case body of brass, suitable for LED batten fitting 9W 230 volts complete all as specified and as directed .
S&F ceiling rose, 3 phase / PVC / Polycarbonate, isolated body complete all as specified and as directed.
Fixing only integrated LED channel tube light fitting, 10/18/20/22 W, 230V, energy efficient box type, integral, sleek polycarbonate with white acrylic cover epoxy powder coated with fluorscent tube light 1X20W complete with all accesories internally pre wired and connectiong up with twin core twisted flexible copper conductor of suitable size, complete all as specified and as directed. Note:- Material shall be issued under Sch 'B' items
Fixing only, connecting and commissioning of energy efficient, pressure die cast aluminium housing with heat resistant toughened glass with frame & IP-66 protection and impact resistance IK 07, LED street light luminaries 25/45 watt 5700K, fixed on pole, incld. 1.60 mtr long 40 mm bore light grade GI pipe mounting bracket made to shape with and including MS clamp of FI 40 mm x 6 mm with nuts, bolts & washers and conductor to fitting with 3 core 1.50 sqmm pvc insulated cable including taking down unserviceable light fitting complete all as per specified and directed by Engg-in-charge. Note:- Material shall be issued under Sch 'B' items
Fixing only, connecting and commissioning of LED luminaire 600 mm x 600 mm, 35/36watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling, incld. 1.60 mtr long 40 mm bore light grade GI pipe mounting bracket made to shape with and including MS clamp of FI 40 mm x 6 mm with nuts, bolts & washers and conductor to fitting with 3 core 1.50 sqmm pvc insulated copper conductor cable including taking down unserviceable light fitting complete all as per specified and directed by Engg-in-charge. Note:- Material shall be issued under Sch 'B' items
M&L for making openings for exhaust fan / ventilating fan in stone wall and making good by plastering / rendering etc around the wall opening, including removing rubbish to out side MD land complete all as specified and as directed.
Taking down & hanging only ceiling/exhaust fan and connecting up including provision of cable from ceiling rose or connector to fan
S&F Single pole and neutral sheet metal enclosure with two pin earth industrial plug and socket with one MCB SP 20 Amps complete all as specified and as directed. Make:- Legrand cat part no. 507811 or its equivalent make of / Havells / L&T / ABB
S&F factory made prewired distribution board in sheet metal enclosure in double door with 200A rated bus bar,SPN 8 way, 240V for fixing MCB's, complete all as specified and as directed. Make:- Legrand / Havells / L&T / ABB
S&F factory made prewired distribution board in sheet metal enclosure in double door with 200A rated bus bar,SPN 12 way, 240V for fixing MCB's, complete all as specified and as directed. Make:- Legrand / Havells / L&T / ABB
S&F factory made prewired distribution board in sheet metal enclosure in double door with 200A rated bus bar,TPN 4 way, 240V for fixing MCB's, complete all as specified and as directed. Make:- Legrand / Havells / L&T / ABB
S&F MCB TPN ‘C’ Curve 10KA, 63 amps, 415 volts, complete all as specified and directed . Make:- Legrand / Havells / L&T
S&F MCB SPN ‘C’ Curve 10KA, 63 amps, 240 volts, complete all as specified and directed . Make:- Legrand / Havells / L&T
S&F MCB SP ‘C’ Curve 10KA, 6 to 32 amps, 240 volts, complete all as specified and directed . Make:- Legrand / Havells / L&T
S&F Verticle distribution board in double door with 300 A rated bus bar,TPN 4 way, 415V, IP-43 protection, suitable for 4 Pole MCCB's 100 A, IP protection 43 & IK 09 , TPN 4 way, dust and vermin proof, complete all as specified and as directed. Note:- MCCB's / MCB's measured and paid separately Make:- Havells cat part No. DHDLVSRWGOFO04 or its equivalent of Legrand / Havells / L&T / ABB
Supply and fixing 4 Pole MCCB 160 Amps 32 KA, 415 Volt, thermal adjustable magnetic type, Ics=75% including sheet metal enclosure powder coated finish and fixed flush in wall including making good to distrubed surface etc complete. Make:- Legrand / Havells / L&T / ABB
M&L in repairs submain wiring with two runs of 6 sqmm with one run of 4 Sqmm earth wire of 1100V grade FRLS PVC insulated multi-stranded copper conductor, single core cable conforming to IS 694 drawn through in and including heavy duty non metallic PVC rigid conduit of 25mm dia with accessories fixed & concealing on wall / ceiling and connected to common earth dolly complete all as specified and directed. Note :- Two runs of 6 sqmm cable & one run of 4 sqmm earth cable and one run of PVC conduit shall be measured as one length for the purpose of measurement.
Supply, laying, jointing, testing and commissioning 1100 volt grade heavy duty, insulated LT under ground cable, sheathed, as per IS- 7098 (Part I) 1988, galvanized steel strip armoured heavy duty multi solid aluminum conductor laid in trenches / passed through pipe/duct road crossing, fixed on poles/ wall with clamps made out of mild steel flat iron including fixing accessories like brass cable glands double compression type, lugs, nuts, bolts, washers etc of size 4 core 16 sqmm complete all as specified and directed
Supply, laying, jointing, testing and commissioning 1100 volt grade heavy duty, insulated LT under ground cable, sheathed, as per IS- 7098 (Part I) 1988, galvanized steel strip armoured heavy duty multi solid aluminum conductor laid in trenches / passed through pipe/duct road crossing, fixed on poles/ wall with clamps made out of mild steel flat iron including fixing accessories like brass cable glands double compression type, lugs, nuts, bolts, washers etc of size 3.50 core 35 sqmm complete all as specified and directed
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel including dismentling of existing earth pit etc complete all as specified and as directed. NOTE :(i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-( ii) Item includes the cost of GI pipe up to 7.5m for protection of earth wire. Any variation in length beyond 7.50 m shall be measured separately.(iii) Item includes cost of lead wire up to 7.5 m Any variation in length beyond 7.50 m shall be measured separately.(iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
Note for all above items:-(i) All items in BOQ are for "Materials and labour / Supply and fix" and to be executed in "Repairs i.e. incld taking down old items" unless optherwise specifically mentioned as "Suppply only" or "fixing only" in BOQ. Contractors are required to quote their rates accordingly. (ii) The contract sum shall be arrived at after duducting amount of schedule of "Credit" from the Total quoted amount.
SN TECHNO CONSTRUCTIONS
M/s Deepshikha Trading Corporation
Bhagwati Construction Company
mahalaxmi enterprises
Jai Doulat Construction Co
M/S KAUTILYA GARG
M/S SUMAN ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .