Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 LAccepted-AOC | ₹4.1 L | L1 | Accepted-AOC L1 |
| 2 | L2₹4.1 LRejected-AOC | ₹4.1 L | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | HAKKIM .M. S L1 | A N JAYAPRASAD L2 |
|---|---|---|---|---|---|
| 1.00building | |||||
| 1.00 | 12.48:Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) | 62.55 | sqm | 434 ₹27,146.70 | 435 ₹27,209.25 |
| 1.00 | 12.49:Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately ). | 16.7 | metre | 97 ₹1,619.90 | 98 ₹1,636.60 |
| 1.00 | 13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand). | 360.57 | sqm | 353 ₹1.3 L | 355 ₹1.3 L |
| 1.00 | OD484271/2025-2026:Engaging Carpenter for re arranging of doors and windows, roof ceiling settings, window glass
fixing etc. including all charges. | 3 | each | 1,197 ₹3,591 | 1,200 ₹3,600 |
| 1.00 | 15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar | 21.06 | cum | 2,129 ₹44,836.74 | 2,130 ₹44,857.80 |
| 1.01 | OD482890/2025-2026:Finish walls with Acryllic Smooth exterior paint of required shade:
Old work ( Two or more coats applied @ 1.67 ltr/10 sqm) on existing cement paint surface | 223.6 | sqm | 139 ₹31,080.40 | 140 ₹31,304 |
| 1.01 | 15.13.1:Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area 3 sq. metres and below | 10 | each | 148 ₹1,480 | 150 ₹1,500 |
| 1.01 | 13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) | 112.49 | sqm | 209 ₹23,510.41 | 210 ₹23,622.90 |
| 1.01 | 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work | 15.15 | sqm | 164 ₹2,484.60 | 165 ₹2,499.75 |
Tender Value
₹4.1 L
EMD Value
₹10,169
Closing Date
2 Mar 2026, 4:00 pmClosed
AEE
OFFICE OF ECECUTIVE ENGINEER PMC
Annual Plan-PMC PRO NO.532/2025-26 - PARAKKUNNAM SCHOOL MAINTENCE IN PALAKKAD MUNICIPALITY-General Civil Work
2026_LSGD_840138_1
24/AEE/LID EW/PMC/2025-26
Open Tender
Civil Works - Others
Palakkad
Please refer Tender documents.
7 documents required · 7 mandatory
₹900
Yes
₹10,169
Yes
18 Mar 2026
24 Feb 2026
3 Mar 2026
24 Feb 2026
2 Mar 2026
24 Feb 2026
building
12.48:Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately)
12.49:Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately ).
13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
OD484271/2025-2026:Engaging Carpenter for re arranging of doors and windows, roof ceiling settings, window glass fixing etc. including all charges.
15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
OD482890/2025-2026:Finish walls with Acryllic Smooth exterior paint of required shade: Old work ( Two or more coats applied @ 1.67 ltr/10 sqm) on existing cement paint surface
15.13.1:Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area 3 sq. metres and below
13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
50.18.9.19.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
OD495093/2025-2026:DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1416046.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.05 MB
BOQ_1416046.xls
BOQ • 0.31 MB
viewsbd_merged.pdf
Tender Documents • 1.67 MB
affidavit.pdf
Tender Documents • 0.34 MB
epayment.pdf
Tender Documents • 0.34 MB
formoftender.pdf
Tender Documents • 0.34 MB
integritypact.pdf
Tender Documents • 0.33 MB
preliminaryagreement.pdf
Tender Documents • 0.35 MB
Download all tender documents and submit your bid