| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹23.9 L+₹1.4 L (6.19%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹25.7 L+₹3.2 L (14.5%)Rejected-Finance 131 SANGAM NAGAR OPP NATIONAL SCHOOL SANGHVI PUNE 411027 | PUNE | MAHARASHTRA | 411027 | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹25.8 L+₹3.4 L (15.1%)Rejected-Finance | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹28.6 L+₹6.2 L (27.5%)Rejected-Finance 7 32 1 PRASANTHI NAGAR GOPALAPATNAM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | L5 | Rejected-Finance Not lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
4 Aug 2022, 6:00 pmClosed
Garrison Engineer P Navy Kalinga Visakhapatnam
Garrison Engineer P Navy Kalinga Military Engineer Services INS Kalinga PO Visakhapatnam 531 163
REPAIR AND MAINTENANCE TO CERTAIN SUB STATION, LT DISTRIBUTION SYSTEM CAPACITOR BANKS AND OTHER ALLIED WORKS AT TP AREA AND NON TP AREA AT INS KALINGA AND NAD BHEEMUNIPATNAM UNDER GE (P) NAVY KALINGA
2022_MES_536482_1
GE (P)/N/K/8933 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer P Navy Kalinga Visakhapatnam
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Garrison Engineer P Navy Kalinga Visakhapatnam
₹70,000
Yes
15 Sept 2022
7 Jul 2022
6 Aug 2022
7 Jul 2022
4 Aug 2022
21 Jul 2022
Amount
Excavation in trenches in soft / loose soil not exceeding 1.5 Mtr in wide and not exc. 1.5m in depth for taking out / laying of under ground cable in trenches or cable ducts all complete all as specified.
Returning, filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick in soil after repairing / jointing and laying and testing of cables complete all as specified
Removing surplus soil to a distance not exceeding 50 Mtr and deposited at a level not exceeding 1.5 mtr above from the starting point complete all as specified
M&L natural river sand as cushioning of cables including spreading and punning down all as per clause No 19.75 of SSR part -I all as specified. Note : Punned thickness shall be measured for payment purpose
Supply and lay un-reinforced precast concrete cable cover class LV, type 1, flat, size 250mmx150mmx40mm for protection of cable, laying in trenches complete all as specified and directed by Engr-in-charge.
Labour charges for re-laying of serviceable bricks of any size and type recovered during taking out of old cable , over newly laid or re-laid cables all complete as specified and directed.
M&L for cutting existing road / PCC drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with PCC 1:3:6 type CI using 20mm graded aggregates complete all as specified
M&L for 50mm dia GI pipe medium grade galvanised for cable protection and sealing both ends including taking out old pipe complete all as specified.
M&L for 80mm dia GI pipe medium grade galvanised for cable protection and sealing both ends including taking out old pipe complete all as specified.
Taking down or out existing cable of sizes 2/3.5/4 core 10 sqmm to 70 sqmm from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by Engineer in charge Note :(1) Excavation / cutting of road or floor/ GI pipe & laying / relaying of cable etc shall be measured and paid separately under respective item of this schedule
All as per Item No 10 but cable of size 3.5 core 95 sqmm to 300 sqmm
Relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 2/3.5/4 core 10 to 70 sqmm in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified Note ;- Lugs and Glands will be measured and paid separately.
All as per Item Sl No 12 above but of size 3.5 core 95 to 240sqmm
Supply & Laying XLPE insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 16sqmm 4 core including necessary cable lugs, glands, insulation tape complete all as directed and specified.
All as per Srl item No. 14 here-in-before but of size 10 sqmm 4 core
All as per Srl item No. 14 here-in-before but of size 25 sqmm 4 core
All as per Srl item No. 14 here-in-before but of size 35 sqmm 3.5 core
All as per Srl item No. 14 here-in-before but of size 50 sqmm 3.5 core
All as per Srl item No. 14 here-in-before but of size 70 sqmm 3.5 core
All as per Srl item No. 14 here-in-before but of size 95 sqmm 3.5 core
All as per Srl item No. 14 here-in-before but of size 120 sqmm 3.5 core
All as per Srl item No. 14 here-in-before but of size 150 sqmm 3.5 core
M&L straight through joint (Heat Shrinkable) for under ground PVC insulated and PVC sheathed armoured heavy duty XLPE cables with aluminium conductor including jointing kit, including making joints for the cable of size 10-16 sqmm x 2/4 core cables including testing and commissioning complete all as specified
All as per Srl item No. 23 here-in-before but of size 25 to 50sqmm x 3.5 / 4 core, as per the size of existing UG cable.
All as per Srl item No. 23 here-in-before but of size 70 to 120 sqmm x 3.5 / 4 core, as per the size of existing UG cable.
All as per Srl item No. 23 here-in-before but of size 150 to 185 sqmm x 3.5 / 4 core, as per the size of existing UG cable.
All as per Srl item No. 23 here-in-before but of size 240 to 300 sqmm x 3.5 / 4 core, as per the size of existing UG cable.
S&F in repair 400 A 4 Pole MCCB, 36/35 KA, 415V, 50 Hz, AC supply, Ics=100% Icu, adjustable Overload 80-100%, thermal magnetic release mechanism including necessary cable lugs & wire etc complete all as specified and directed.
All as per Srl item No. 28 here-in-before but of capacity 250 A 4 pole MCCB, Icu=35/36 KA.
All as per Srl item No. 28 here-in-before but of capacity 200 A 4 pole MCCB, Icu = 25/26 KA.
All as per Srl item No. 28 here-in-before but of capacity 125 A 4 pole MCCB, Icu = 18 KA.
All as per Srl item No. 28 here-in-before but of capacity 63 A 4 pole MCCB, Icu = 18 KA.
S&F in repair of CT's epoxy cast resin , with primary Current 400A - 650A or as per existing panel ratings suitable for relays and Secondary current 5A , Dual core , Dual Ratio. Protection core -Class 5P10 & Metering core - Class 0.5 , 2.5 VA . Suitable for LT 415V panel incoming feeders.
S&F in repair aluminium lugs suitable for 240 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed.
All as per Srl item No. 36 here-in-before but for 185 Sqmm
All as per Srl item No. 36 here-in-before but for 120 Sqmm,
All as per Srl item No. 36 here-in-before but for 95 Sqmm,
All as per Srl item No. 36 here-in-before but for 70 Sqmm,
All as per Srl item No. 36 here-in-before but for 50 Sqmm,
All as per Srl item No. 36 here-in-before but for 25 Sqmm,
All as per Srl item No. 36 here-in-before but for 16 Sqmm Sqmm,
M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth strip 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3, connected to earthing point of outdoor panel boards all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering , water funnel, complete all as specified and testing on completion.
S&F in repair 250 A 4 Pole Change over switch, 50 KA, 415V, 50 Hz, AC supply, I - O - II operation, manual type, open construction or closed type construction as per site requirement, adjustable type of thermal and magnetic setting, handle, including necessary cable lugs & wire etc complete all as specified and directed.
S&F in repair 160 A 4 Pole Change over switch, 50 KA, 415V, 50 Hz, AC supply, I - O - II operation, manual type, open construction or closed type construction as per site requirement, adjustable type of thermal and magnetic setting, handle, including necessary cable lugs & wire etc complete all as specified and directed.
S&F in repair double compression weatherproof brass cable gland heavy duty , nickel plated of size OD 23mm-26mm (cable size 10/16 sqmm) all complete as specified and as directed Note: The quoted rate is inclusive of disconnecting the existing cable from electrical panel board and reconnecting it to the panel board after replacing the gland.
All as per Srl item No. 47 here-in-before but of size OD 26mm - 30mm (cable size 25/35 sqmm)
All as per Srl item No. 47 here-in-before but of size OD 33mm - 37mm (cable size 50/70 sqmm)
All as per Srl item No. 47 here-in-before but of size OD 41mm - 46mm (cable size 95 / 120 sqmm)
All as per Srl item No. 47 here-in-before but of size OD 52mm - 61mm (cable size 185/240 sqmm)
M&L for dismantling the cable connections of 3/4 pole Air circuit breaker of capacity 630 to 1000 Amps ,415 V 50 HZ of Any make, strip opening the Air circuit breaker, inspecting the parts for serviceability/ overhauling complete and carrying out the following repairs/maintenance :- (Srl item No. 52 is here-by continued as Srl item No. 52.10 to 52.80)
a) Cleaning the insulation parts including bushings with CTC solution.
b) Checking the alignment and condition of movable and stationary contacts and adjust them all as per manufacturer's instructional manual
c) Check the bolts, nuts, washers, cotter pins and all terminal connections are in place and tights. Replace the worn-out parts.
d) Check arc chutes for damage and replace damaged parts.
e) Clean and lubricate the operating mechanism with a light machine oil (SAE-20 or 30) for pins and bearings and with a non-hardening grease for the wearing surfaces . Adjust breaker operating mechanism all as per manufacturer's instructional manual . Replace if there is excessive wear and tear.
f) Checking / inspecting shunt trip coil for serviceability and replacing the same if required.
g) Replacing the badly worn or burned contacts. Checking control device free for operation.
j) Check after servicing the circuit breaker to verify the contacts move to the fully opened and fully closed positions, that there is an absence of friction and that the electrical operation is functional
Note : The rate quoted deemed to be inclusive of T&P and minor spares like lubricants, nuts/bolts/washers/ pins etc. Major spares like contacts, shunt trip coil , relays, CTs etc will be measured & paid separately under relevant schedule items
S&F in repair XLPE insulated, armoured, earthed, heavy duty electric cable with Copper conductor , 1100 Volt grade, cross sectional area 16 sqmm 1 core complete all as directed and specified.
S&F in repair XLPE insulated, armoured, earthed, heavy duty electric cable with Copper conductor , 1100 Volt grade, cross sectional area 35 sqmm 1 core complete all as directed and specified.
S&F in repair Copper lugs suitable for 16 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed.
S&F in repair Copper lugs suitable for 35 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed.
Supply only auxiliary contact block suitable for air circuit breakers of rating 400 to 1000 Amps rating as all per existing make.
Supply only of Breaker Main Contact Set suitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing make.
Supply only of Spring charging handle assembly suitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing make.
Supply only of Shutter for guide frame suitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing make.
Supply only of Overcurrent release suitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing make.
Supply only of Front facia for drawout breakers suitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing make.
Supply only of arcing contacts (fixed/ moving) suitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing make.
Supply only of arc chutes (for 415 V) suitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing make.
Supply only of closing coil suitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing make.
Supply only of trip coil suitable for air circuit breakers of rating 400 to 1000 Amps rated all as per existing make.
S&F in repair 300/320 A 4 Pole MCCB, 36/35 KA, 415V, 50 Hz, AC supply, Ics=100% Icu, adjustable Overload 80-100%, thermal magnetic release mechanism including necessary cable lugs & wire etc complete all as specified and directed.
suresh electricals
LEO ENTERPRISES
SRI SAI KRISHNA ENGINEERING WORKS
MVV Prasad
VASANTHA NAIDU ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .