Loading…
Loading…
Tender Value
Refer Docs
Closing Date
24 Sept 2026, 5:00 pm
DDE/M, Mandi Parishad, Lko
Kisan Mandi Bhawan, Vibhuti Khand, Gomti Nagar Lko
S/I/T/C of AMF Panel, Emergency Distribution Board etc. at Kisan Mandi Bhawan, Lko.
2026_RKUMP_1181576_1
E/M/325/2026-
Open Tender
Electrical Works
Item Rate
Kisan Mandi Bhawan, Lko.
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
3 Sept 2026
3 Sept 2026
25 Sept 2026
3 Sept 2026
24 Sept 2026
3 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S/I/T/C of cubicle type indoor mounting Powder coated (Siemen's Gray) AMF panel with body made up of 16SWG CRCA sheet with suitable angle iron, iron strip, etc. All doors will be made up of 16SWG, covered with rubber biding so that they will be completely dust and vermin proof. All instruments fitting screws and nut bolts used will be zinc polished including busbar strip connections. Control section wiring will be done with appropriate wire. Proper lugging in all the connections. Wiring shall be done with appropriate PVC channels, binding strip and cable ties. The panel should have proper depth for maintenance/repair purpose. Panel should have both top and bottom cable entry and capable for extension on both sides. The Job includes the grounting of the board as per directions of Engineer-in charge complete in all respects.
ACB FP 800Amp 1no. (L&T/Scnieder/ABB/Siemens)
Contactor 600Amp 1 no.(L&T/Scnieder/ABB/Siemens)
MCCB FP 630Amp 1No. (L&T/Scnieder/ABB/Siemens)
All busbar FP 1000Amp inslutated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides.
Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment. Battery Amp. meter 0-15A
Battery Voltmeter 0-30V
Charging selector switch 1 no. (Rep make)
Push button with element 4No. (Rep make)
Mode selector switch 1No.(Rep make) | 1 | No | - | - |
| 1.2 | SPP 1No.(Rep Make)
Control MCBs: 6/20Amp 6No.(L&T/Scnieder/ABB/Siemens)
Hooter 24DC for panel 1no.
Indicating lamps 6No.
Engine start/stop replay 25Amp 2no. and Control termination as required
Programmable AMF module with LCD display having following features:-
- Three attempt engine start relay
- On delay timer for load changeover
- On delay timer for engine shut down
- Engine cranking relay with adjustable time delay
- Built in adjustable timers: Mains wait, cranking wait, cranking ON, cranking OFF, cranking Attempts, Stop solenoid, Engine idle run.
- Alternator over voltage protection
- Alternator under voltage protection
- LLOP protection
- HWT/HCT protection
- Auto/Manual Selection
- Mains over under voltage protection
- Push button: start, Stop, Mains close/trip, Alt close/trip
- over/under frequency | - | - | - | - |
| 2 | S/I/T/C of cubicle type indoor mounting Powder coated (Siemen's Gray) LT distribution panel / Emergency distribution board with body made up of 16SWG CRCA sheet with suitable angle iron, iron strip, etc. All doors will be made up of 16SWG, covered with rubber biding so that they will be completely dust and vermin proof. All instruments fitting screws and nut bolts used will be zinc polished including busbar strip connections. Control section wiring will be done with appropriate wire. Proper lugging in all the connections. Wiring shall be done with appropriate PVC channels, binding strip and cable ties. The panel should have indicating lamps, 3in1 meter, busbar isolators. The panel should have proper depth for maintenance/repair purpose. Panel should have both top and bottom cable entry and capable for extension on both sides. The Job includes the grounting of the board as per directions of Engineer-in charge complete in all respects.
Incoming:
On load changeover: 630Amp 2No. (L&T/Scnieder/ABB/Siemens)
Busbar:
Aluminium busbar TPN 800Amp. inslutated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides.
Outgoing:
MCCB TPN 400Amp 2No (L&T/Scnieder/ABB/Siemens)
MCCB TPN 320Amp 2No. (L&T/Scnieder/ABB/Siemens)
MCCB TPN 250Amp 1No. (L&T/Scnieder/ABB/Siemens)
MCCB TPN 63Amp 1No. (L&T/Scnieder/ABB/Siemens) | 1 | No | - | - |
| 3 | S/F of 12 core 2.5sqmm stranded copper conductor, PVC insulated, armoured control cable (1.1KV grade) for 250KVA DG set and AMF panel | 1 | Mtr | - | - |
| 4 | S/F of 800Amp ACB FP 50kA with retro fitting. (L&T/Scnieder/ABB/Siemens) | 1 | No | - | - |
| 5 | Buy back price of existing/old AMF panel including dismanteling, porper stacking and cartage. | 1 | Job | - | - |
| 6 | Buy back price of existing/old emergency distribution board (EDB) including dismanteling, porper stacking and cartage. | 1 | Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.59 MB
494EQuotation.pdf
Tender Documents • 0.57 MB
BOQ_2222811.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].