| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 LAccepted-AOC HOUSE NO 43 VPO KOT DISTRICT PANCHKULA 134118 | PANCHKULA | HARYANA | 134118 | L1 | Accepted-AOC LOA | |
| 2 | L2₹1.3 L+₹5,953 (4.99%)Rejected-Finance | L2 | Rejected-Finance Highest | |
| 3 | Rejected-Technical | - | Rejected-Technical Non responsive |
Tender Value
₹1.4 L
EMD Value
₹2,800
Closing Date
20 Dec 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
NAVEEN RATHEE
Executive Engineer Electrical Division PWD B and R Ambala Cantt
Setting up of Machine Lab in the campus of Govt. Polytechnic College, Sec.-26, Panchkula. (Pdg. E.I Only). (Recall)
2023_HRY_333585_2
202304173D07 72A6 46D4 B725 D2727ED7760B663BAR
Open Tender
Electrical Works
Works
110 days
Ambala Cantt
Setting up of Machine Lab in the campus of Govt. Polytechnic College, Sec.-26, Panchkula. (Pdg. E.I Only). (Recall)
2 documents required · 2 mandatory
₹500
₹2,800
Yes
13 Jun 2024
14 Dec 2023
20 Dec 2023
14 Dec 2023
20 Dec 2023
14 Dec 2023
Amount
[23.22.1.10]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.10. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 125 to 160 amp, 25 KA
[23.22.4.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.1. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 4 way ( 2 incoming and 2 outgoing)
[23.22.4.10]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.10. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 6 way ( 8 incoming 3phase*6 outgoing)
[23.22.5.6]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.6. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs TRIPLE POLE
[23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE
[23.5.6.3]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm)
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.
Supply and Erection of MS frame of height 4 Feet x 1 Feet (W) made by MS angle iron of size 50mm x 50mm x 3mm thickness and MS plate of size 1 Feet x 1 Feet of 3mm thickness. The frame made/fixing with help of welding work and fastner of 8mm size to complete the job in all respect with the help of all petty mterial and labour up to the entire satisfaction of Engineer in Charge of work.
Supply and Erection of PVC insulated Copper armored cable 25 Sqmm x 4 Core 1100 Volts grade to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work. Make- Havell`s / Polycab / R.R
Nardev Singh Contractor
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .