| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAccepted-AOC PLOT NO 102 H NO 21 1382 102 GROUND FLOOOR SAMATHA NAGAR COLONY OLD SAFILGUDA ROAD NO 3 HYDERABAD RANGAREDDI TELANGANA 500056 | HYDERABAD | TELANGANA | 500056 | ₹2.2 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹2.5 Cr+₹27.1 L (12.3%)Rejected-Finance | ₹2.5 Cr+₹27.1 L (12.3%) | L2 | Rejected-Finance Being not lowest |
| Sl No | Description | Qty | Unit | YAGYA AGARWAL CONSTRUCTIONS AND INFRA SOLUTIONS PVT LTD L2 | Squad 7 Projects and Services Pvt Ltd L1 |
|---|---|---|---|---|---|
| .10NOTE: Schedule ‘A’ Part I under Ser No. 1 is not Prepriced by MES and prepriced rates indicated as 0.00 under column no. 5 signifies this fact only (ie. TO BE QUOTED BY THE CONTRACTOR). Structural design of buildings/ structures covered under this schedule is to be done by the contractor. | |||||
| 1.00 | Provision of OFFICER'S MESS DINNING HALL BLOCK INCLUDING FRONT VERANDAH AND CONNECTING VESTIBULE in RCC framed structure including structural designing complete all as shown in architectural drawings and schedule of finishes and as specified and directed. | 1 | Each | 2,03,42,975 ₹2,03,42,975 | 1,75,00,000 ₹1,75,00,000 Lowest |
| 1.01NOTE: Schedule ‘A’ Part II to VIII are under Ser No. 2 to 8 are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. | |||||
| 2.00 | Lump sum price worked out for DEMOLITION/ DISMANTLING as listed in Sch 'A’ Part II | 1 | Lumpsum | 1,36,725 ₹1,36,725 Lowest | 2,07,391 ₹2,07,391 |
| 3.00 | Lump sum price worked out for EXCAVATION AND EARTHWORK as listed in Sch 'A’ Part III | 1 | Lumpsum | 2,50,000 ₹2,50,000 Lowest | 3,93,547.8 ₹3,93,547.8 |
| 4.00 | Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch 'A’ Part IV | 1 | Lumpsum | 7,50,000 ₹7,50,000 Lowest | 7,78,852.88 ₹7,78,852.88 |
| 5.00 | Lump sum price worked out for PATH as listed in Sch 'A’ Part V | 1 | Lumpsum | 75,000 ₹75,000 Lowest | 85,905.15 ₹85,905.15 |
| 6.00 | Lump sum price worked out for AREA DRAINAGE as listed in Sch 'A’ Part VI | 1 | Lumpsum | 4,75,000 ₹4,75,000 Lowest | 5,37,984.82 ₹5,37,984.82 |
| 7.00 | Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch 'A’ Part VII | 1 | Lumpsum | 2,20,000 ₹2,20,000 Lowest | 2,96,019.86 ₹2,96,019.86 |
| 8.00 | Lump sum price worked out for EXTERNAL ELECTRIFICATION as listed in Sch 'A’ Part VIII | 1 | Lumpsum | 6,75,000 ₹6,75,000 Lowest | 7,87,698.6 ₹7,87,698.6 |
Tender Value
₹2.2 Cr
EMD Value
₹3.0 L
Closing Date
23 Jul 2025, 6:00 pmClosed
CE (AF) Gandhinagar
HQ CE (AF) Gandhinagar, Lekhawada Patia, Chiloda - 382042
ADDITION/ ALTERATION TO BUILDING NO P-90 AT VSN GANDHINAGAR
2025_MES_700932_3
89393/E8
Open Tender
Civil Works
Lump-sum
365 days
GE (AF) Chiloda
All as per NIT and Tender Documents
7 documents required · 7 mandatory
₹2,000
GE (AF) Chiloda
₹3.0 L
Yes
30 Sept 2025
17 May 2025
25 Jul 2025
17 May 2025
23 Jul 2025
9 Jul 2025
18 May 2025 - 24 May 2025
Amount
NOTE: Schedule ‘A’ Part I under Ser No. 1 is not Prepriced by MES and prepriced rates indicated as 0.00 under column no. 5 signifies this fact only (ie. TO BE QUOTED BY THE CONTRACTOR). Structural design of buildings/ structures covered under this schedule is to be done by the contractor.
Provision of OFFICER'S MESS DINNING HALL BLOCK INCLUDING FRONT VERANDAH AND CONNECTING VESTIBULE in RCC framed structure including structural designing complete all as shown in architectural drawings and schedule of finishes and as specified and directed.
NOTE: Schedule ‘A’ Part II to VIII are under Ser No. 2 to 8 are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for DEMOLITION/ DISMANTLING as listed in Sch 'A’ Part II
Lump sum price worked out for EXCAVATION AND EARTHWORK as listed in Sch 'A’ Part III
Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch 'A’ Part IV
Lump sum price worked out for PATH as listed in Sch 'A’ Part V
Lump sum price worked out for AREA DRAINAGE as listed in Sch 'A’ Part VI
Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch 'A’ Part VII
Lump sum price worked out for EXTERNAL ELECTRIFICATION as listed in Sch 'A’ Part VIII
SCHEDULE `A' PART-IX MISCELLANEOUS ITEMS (Note for items 9 to 24: The contractor shall quote his rate for each of these items separately. The estimated rate is left blank since the same is not prepriced by MES)
INTERNAL ELECTRIFICATION
Taking down existing split A/C indoor and outdoor unit of capacity 1.5/ 2.0 TR complete, including fixture and fittings such as metal plates, copper pipe, out door stand etc. removing materials and depositing to MES store for keeping in safe custody and refixing the same as per direction of Engineer-in-Charge complete all as specified and directed.
Taking down old LT cable with junction boxes and DBs etc. and depositIng to MES store for keeping in safe custody and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Supply and fix wall mounting fans 400 mm sweep, single phase, 240 volts complete all as specified and directed.
Supply and fix vertical load line TPN DB double door complete encloser type (TPN) six way 415 Volts with IP 54 protection complete, including the following: Incoming side: (a) MCCB of 160 amps 4 pole 25 KA, 50 Hz Outgoing side: (a) 40 Amp MCB TP 10 KA, C-Series- 06 nos for outgoing including complete grouting on wall with nut and bolt properly and as directed by Engr-In-Charge.
Supply and fix vertical load line TPN DB double door complete encloser type (TPN) six way 415 Volts with IP 85 protection complete, including the following: Incoming side: (a) MCCB of 160 amps 4 pole 25 KA, 50 Hz Outgoing side: (a) 6-32 Amps MCB SP10 KA, C-series - 12 Nos (b) 40 Amp MCB TP 10 KA, C-Series- 02 nos for outgoing including complete grouting on wall with nut and bolt properly and as directed by Engr-In-Charge.
Supply and fix SPN DB double door complete encloser type (SPN) Eight way of capacity 220-230 Volts with IP 65 protection complete, including provision of incoming MCB SPN of capacity 40 Amp and out going SP- 6-32 Amp 6 nos complete including complete grouting on wall with nut and bolt properly and as directed by Engr-In-Charge.
Supply and fix integral Bollard light cast aluminium housing aluminium louvers, opal acrylic diffuser with IP 65 with LED 10 Watt including driver complete all as specified and directed. Note: Light should have minimum lumen output of 1500 lumens and minimum system efficiancy>100 lumen/watt., PF>0.90. The light should have a colour temp of 6500 K & CRI >80 of cool white and mounted on necessary steel fabricated stand upto 400 mm length including in ground PCC work (1x1) in feet complete.
Supply, installation, commisioning and testing factory made and tested, TTA type LT Panel (Type tested Assembly) as per IEC 61439 standards of size 3(L) x 3(H) x 1.5(W) in feet, outdoor type, mounted on rigid angle iron frame, suitable size, having independent compartment for insulated aluminium bus bar, incoming feeder and each out going feeder, dust and vermin proof, factory made, fabricated out of not less than 3.15 mm thick CRCA sheet with IP-65 protection suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with aluminium bus bar of 400 Amp rating for 3 phase and neutal 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators- 01 Set, Cable glands with independent plates at bottom for each outgoing and incoming cables in cable alley and complete board painted with powder coating in siemens grey colour front and rear opening type with double door shutter and locking arrangement including provision of 65 mm Godrej (freedom) lock with 2 keys, suitable aprons for cable entry/ exist, including taking down and refixing of exisiting cable properly with lugs and thimable all as approved and comprising as under:
Supply and fix SPN DB double door complete encloser type (SPN) four way of capacity 220-230 Volts with IP 65 protection complete, including provision of incoming MCB SPN of capacity 32 Amp - 01 Nos and out going SP- 10 Amp -2 Nos complete including complete grouting on wall with nut and bolt properly and complete all as specified and as directed
EXTERNAL ELECTRIFICATION
Boring of holes under road, pavement, hardstanding using trenchless technology using manual technology incl HDPE pipe of 150mm dia suitable for 0.4 Mpa working pressure complete all as specified and directed.
M & L for DWC pipe laying in trenches/under floors/on walls for protection of UG cables of 110mm OD, complete with coupler and connected accessories all as specified and directed Note : Cutting of floor/road and making the surface good with PCC type B1 1:2:4 (20mm graded aggregate) is deemed to be included in the Item rate.
M & L for DWC pipe laying in trenches/under floors/on walls for protection of UG cables of 90mm OD, complete with coupler and connected accessories all as specified and directed Note : Cutting of floor/road and making the surface good with PCC type B1 1:2:4 (20mm graded aggregate) is deemed to be included in the Item rate.
Supply, installation, commisioning and testing factory made and tested, TTA type LT Panel (Type tested Assembly) as per IEC 61439 standards of size 3 (L) x 3 (H) x 1.5 (W) in feet, outdoor type, mounted on rigid angle iron frame of suitable size (50 x 50 x 8mm), having independent compartment for insulated aluminium bus bar, incoming feeder and each outgoing feeder, dust and vermin proof, factory made, fabricated out of not less than 3.15 mm thick CRCA sheet suitable for 3 phase 415 volts 50 Hz AC supply, bus bar chamber with aluminium bus bar of 1200 Amp rating for 3 phase and neutral 4 wire system duly insulated with heat shrikable type sleeves as per colour code, supported on epoxy insulators - 01 set, cable glands with independent plates at bottom for each outgoing and incoming cable in cable alley and complete board painted with powder coating in siemens grey colour front and rear opening type with double door shutter and locking arrangement including provision of 65 mm Godrej (freedom) lock with 2 keys, suitable aprons for cable entry/ exit, necessary excavation as required and PCC 1:3:6 (40 mm graded aggregate) type C2 for foundation for angle iron leg frame work including fixing of existing cable properly with lugs and thimble complete all as specified and approved and comprising following accessories:
INCOMING SIDE: (i) AI bus bar 1200 Amp cap- 1 set (set of four strips) (ii) ACB 630 Amp 415V TPN 50 KA- 1 no. (incoming) (iii) Digital voltmeter 0- 500 V- 1 no. (iv) Digital amperemeter 0- 1000 A- 1 no. (v) Indicator lamp LED type R, Y, B - 3 no.s (vi) Change Over Switch On load 630 A- 1 no. OUTGOING SIDE: (i) MCCB 500 Amp, 415 V, 4 pole, 25 KA with spreader links- 2 no. (ii) Space for MCCB 250 Amp, 4 pole- 1 no. (iii) MCCB 400 Amp, 16 KA, 4 pole- 1 no.s (for APFC)
Supply, installation, commisioning and testing factory made and tested, TTA type LT Panel (Type tested Assembly) as per IEC 61439 standards of size 3 (L) x 3 (H) x 1.5 (W) in feet, outdoor type, mounted on rigid angle iron frame of suitable size (50 x 50 x 8mm), having independent compartment for insulated aluminium bus bar, incoming feeder and each outgoing feeder, dust and vermin proof, factory made, fabricated out of not less than 3.0 mm thick CRCA sheet suitable for 3 phase 415 volts 50 Hz AC supply, bus bar chamber with aluminium bus bar of 400 Amp rating for 3 phase and neutral 4 wire system duly insulated with heat shrikable type sleeves as per colour code, supported on epoxy insulators - 01 set, cable glands with independent plates at bottom for each outgoing and incoming cable in cable alley and complete board painted with powder coating in siemens grey colour front and rear opening type with double door shutter and locking arrangement including provision of 65 mm Godrej (freedom) lock with 2 keys, suitable aprons for cable entry/ exit, necessary excavation as required and PCC 1:3:6 (40 mm graded aggregate) type C2 for foundation for angle iron leg frame work including fixing of existing cable properly with lugs and thimble complete all as specified and approved and comprising following accessories:
INCOMING SIDE: (i) AI bus bar 800 Amp cap- 1 set (set of four strips) (ii) On load Change Over Switch 400 Amp cap- 1 no. (iii) MCCB 500 Amp, 415 V TPN 35 KA- 1 no. (iv) Digital voltmeter 0- 500 V- 1 no. (v) Digital amperemeter 0- 500 A- 1 no. (vi) Indicator lamp LED type R, Y, B - 3 no.s OUTGOING SIDE: (i) MCCB 100 Amp, 4 pole, 16 KA with spreader links- 2 no.s (set of 4 Nos Each) (ii) MCCB 200 Amps, 4 Pole, 25 KA with spreader links - 1 Nos (set of 4 Nos Each) (iii) MCCB 125 Amps, 4 Pole, 16 KA with spreader links - 1 Nos (set of 4 Nos Each)
Supply and Installation, testing and commissioning of Auto Power factor improvement capacitor panel outdoor type having aggregate capacity 250 KVAR in 7 stage with micro processor based control, factory made indoor type, platform mounted, suitable for 440 volts 3 Phase 4 wire, 50 Hz AC supply system, having duly insuated copper bus bars, dust and vermin proof, IP 54 class protection and made of 1.6mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, fixed on PCC, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement (incl provn of 65mm Godrej (Navtal) lock with 2 keys , internal wiring with PVC insulated, solid copper conductor, FRLS cables, IS -694 marked of adequate size but not less than 2.5 sqmm and comprising of followings ;- (i) Power factor corrector relay 7 stage Microprocessor based, modular type, intelligent thyristor switch module (VTSM) type APFC relay capable of having auto operation to maintain power factor between 0.85 to 0.99 with digital indication of power factor, preset parameters and having in built capability of indication and elimination of defective capacitor steps - 01 Nos
Supply and fix chain link fencing, MS galvanised, of any size and shape, for transformer protection with clear distance around transformer, with two side opening, including excavation, MS angle iron posts, drilling holes, fixing with nuts and bolts or welding and applying two coats synthetic enamel paint to all steel surfaces complete all as specified and directed.
NOTE: Amount of credit of Rs. 28,300.00 for retrieved materials is mentioned in schedule of credit on Srl Page No. 52 of tender documents in pdf form which will be deducted offline while acceptance of tender.
YAGYA AGARWAL CONSTRUCTIONS AND INFRA SOLUTIONS PVT LTD (BID ID -3368679)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .