Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 LAccepted-AOC 10 MAKHAN LAL SADHUKHAN LANE PO PS BARRACKPORE KOLKATA 700120 W B | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | L1 | Accepted-AOC Lowest quoted bidder. | |
| 2 | L2₹16.7 L+₹2.2 L (15.3%)Rejected-Finance 37 205 A 2 A 1 BUNDHU KATRA GWALIOR ROAD AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance Higher quoted bidder. | |
| 3 | L3₹19.6 L+₹5.1 L (35.2%)Rejected-Finance SRIPUR BICHWA VILLAGE MAJRA FARM KHATIMA UDHAM SINGH NAGAR UTTARAKHAND 262308 | KHATIMA | UDHAM SINGH NAGAR | UTTARAKHAND | 262308 | L3 | Rejected-Finance Higher quoted bidder. | |
| 4 | Rejected-Technical 160 PREM NAGAR BAREILLY | - | Rejected-Technical wrong DD is uploaded which has already been encashed in other work |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
22 Jan 2024, 6:00 pmClosed
GE Pithoragarh
GE Pithoragarh Post - Bharkatiya Pithoragarh - 262520
PROVN OF 02 x SENTRY POSTS, STAINLESS STEEL PLATE RACKS, SECURITY LIGHT AND SPECIAL REPAIR OF CERTAIN TOILET AND BATHROOM BLOCK AND OTHER MISC WORKS AT MIL STN BANBASA.
2023_MES_634219_1
8570/PGH/E8
Open Tender
Civil Works
Item Rate
180 days
Banbasa
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Pithoragarh
₹42,000
Yes
29 Feb 2024
23 Dec 2023
29 Jan 2024
23 Dec 2023
22 Jan 2024
8 Jan 2024
25 Dec 2023 - 30 Dec 2023
Amount
DESCRIPTION OF ITEMS
S & F of wall mounted stainless steel plate rack of size 31"x 30"x 10" and of minimum 0.80mm sheet thickness and weighing not less than 7.5Kg complete all as specified and directed by Engineer-in-charge.
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth, for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
M & L for removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and directed.
M & L for PCC 1:4:8 type-D2 (using 40mm graded stone aggregate) in foundation ,filling and mass concrete complete all as specified and directed.
M & L for brickwork with old sized sub-class ‘B’ burnt clay bricks, straight or curved on plan exc 6m mean radius built in CM(1:6) complete all as specified and directed.
M & L for 10mm thick cement plaster in CM (1:6) on other than fair surfaces of brick wall finished even & fair complete all as specified and directed.
M & L for 15mm thick cement plaster in CM (1:4) on fair faces of brick walls finishing the surface even and fair complete all as specified and directed.
M & L for 5mm thick cement plaster in CM (1:3) on ceiling surfaces finished even & fair complete all as specified and directed.
M & L for preparing newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M & L for preparing the newly plastered surfaces of ceiling and applying three coats of white wash on complete all as specified and directed.
M & L for preparation of newly plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
M & L for RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M & L for RCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), work in rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, work in rough finished surfaces of concrete complete all as specified and as directed.
M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 8mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for 40mm thick damp proof course in cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregate) to horizontal or vertical surfaces including necessary formwork and using water proofing compound as per manufacturer's instructions complete all as specified and directed (WPC shall be measured and paid separately).
Supply only liquid water proofing compound.
M & L for 100mm thick PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed.
M & L for non-skid ceramic coloured floor tiles exc 0.11sqm but not exc 0.18sqm including bedded and jointed in neat cement slurry and pointed with white cement with pigment to match the shade of tile over 15mm thick screed bed in CM(1:6) complete all as specified and directed.
M & L IInd class hard wood plain solid straight chowkats and frame wrought, framed rebated on the solid put together with glue, pinned at joints and fixed in position complete all as specified and directed.
M & L for plain cement concrete type C-1 (1:3:6) using 20mm graded stone aggregate for embedding of holdfasts and filling of pressed steel frames/chowkhats etc complete all as specified and directed.
S & F 30 mm thick flush door shutter solid core construction with block board core and plywood face panels commercial type on both side including teak wood lipping 6mm thick fixed with nails complete all as specified and directed.
S & F mild steel butt hinges of medium weight and fixed 100mm all as specified and directed.
S & F aluminium handle, cast type anodised size of handle 125mm ISI marked complete all as specified and directed.
S & F 200mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
S & F aluminum anodised sliding door bolt 250mm fixing with bolt and sliding bolt of extuded section all as specified and directed.
M & L for preparation of new wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M & L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for 75mm thick cement concrete type-C1 (1:3:6) using 20mm graded aggregate as in path, plinth protection finished surface even and smooth with out using extra cement all as specified and directed.
Demolition of cement concrete unreinforced in any description and in any position removal of debris from site all as specified and directed.
M & L for 75mm thick cement concrete type C2 (1:3:6) using 40mm graded stone aggregate for plinth protection, path etc finished surface even and smooth without using extra cement all as specified and directed.
Demolition of brick work built in cement mortar all as specified and directed.
Taking down cement plaster of any description in any position including raking out joints making for key, scrubbing down with water etc and removal of debris from site all as specified and directed.
M & L for 15mm thick rendering in CM(1:6) on other than fair faces of brick walls and finishing the surface even and and smooth with out using extra cement complete all as specified.
M & L for preparing the new surfaces of walls and applying three coats of white wash on complete all as specified and directed.
Dismantling floor hearth, wall tiling including cement mortar bedding, backing complete all as specified and directed.
M & L for non-skid ceramic coloured floor tiles exc 0.11sqm but not exc. 0.18sqm as in floors set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade over and including 15mm thick screed bed in CM(1:6) complete all as specified and directed.
M & L for glazed ceramic coloured wall tiles 300x450x7 to 8mm thick as in vertical surface such as skirting/dado tiles set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade over and including 10mm thick rendering in CM(1:4) complete all as specified and directed.
Taking down chowkats or frames with shutter(without taking off shutter from the frame) area not exc. 1.5 sqm and making the surface of brick wall good plastering, around the opening complete all as specified and directed.
Taking down chowkats of any description without taking off shutter from the frame exceeding 1.5 sqm but not exc. 4.0 sqm each and making the surface of brick wall good plastering, around the opening complete all as specified and directed.
S & F in repair of Stainless Steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and direceted.
S & F of fibre glass reinforced plastic (FRP) door frames of cross section 95mm X45 mm having double rebate of 32mmX15mm to recive shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resign and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three leg the frame shall be covered with fibre glass in all side MS stay shall be provided bottom to steady the frame complete as specified by the manufacture and as per the direction of Engineer-in-charge.
Supply and fixing 30 mm thick fiber glass reinforced plastic (FRP) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester esin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table 3 of IS: 14856 complete all as specified by the manufacturer and as per directions of Engineer- in-charge.
S & F of aluminium butt hinges medium weight 100mm type C-21 complete all as specified and directed.
S & F of 150mm aluminium anodised barrel tower bolt complete all as specified and directed.
S & F of 150mm aluminium anodised handles cast type complete all as specified and directed.
Taking down GI pipes and connection including cleaning for refixing or removal to store of 15mm bore complete all as specified and directed.
Taking down GI pipes and connection including cleaning for refixing or removal to store of 20mm bore all as directed.
Cutting chases in brick walls for concealed water tubing or concealed conduit wiring, etc., and making good in PCC or CM(1:3) not exceeding 10 cm girth complete all as specified and directed.
S & F of galvanised iron tubing medium grade, with all fittings and fixed complete to wall and ceiling or laid in floors concealed where necessary bore of tube 15mm all as specified and directed.
S & F of galvanised iron tubing medium grade, with all fittings and fixed complete to wall and ceiling or laid in floors concealed where necessary bore of tube 20mm all as specified and directed.
Supply, hoisting and fixing in repairs of rotational moulded PVC water storage tank, 500 litres capacity cylindrical vertical type triple-layered with closed top including inlet,PVC float valve and necessory fittings outlet and wash out holes of approved make including dismantling of existing tank of any description and removing from site of work complete all as specified and as directed.
S & F in repairs of vitreous china squatting pan 'Orissa' pattern of size 580mm x 440mm white with integral foot rest with 'P' or 'S' trap, front or back inlet and connection to trap with cement concrete bedding etc complete all as specified or as directed.
S & F in repair PVC valveless, syphonic action type, flushing cistern, 10 litre capacity, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed.
S & F of vitreous china wash hand basin white flat back of size 550mm x 400mm including cutting for and pinning ends of brackets including 32mm bore PTMT waste coupling (half or full threaded) and PVC waste pipe 32mm dia and 15mm bore PVC connection 450mm long with brass union and jam nuts on both sides and fixed on a pair of MS cantilever bracket of appropriate size complete all as specified and directed.
S & F in repairs of 15mm bore dia Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S & F in repairs of 15mm dia PVC connection with PTMT nuts of length 450mm complete all as specified.
S & F of 15mm bore angular stop cock fancy type, cast copper alloy chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed.
S & F in repairs of 15mm CP fancy type bib cock long body all as specified and directed.
S & F in repairs of brass chromium plated towel rail 20mm dia D type 60cm long all as specified and directed.
S & F in repairs of soap dish holder CP all as specified and directed.
S & F of 125mm chromium plated grating with or without waste hole all as specified and directed.
Taking down rainwater pipes (any size or pattern), including all fittings heads, shoes, bends, swan-necks etc., including cleaning or refixing or removal to Store (measured over all as fixed along the centre line over fittings and accessories) complete all as specified and directed.
S & F of PVC (SWR) 110mm dia rain water pipe single socket any length with rubber rings joints fixed to walls complete all as specified and directed.
S & F of PVC (SWR) 110mm dia bend any radius including cutting brick wall / concrete and making good the disturbed surfaces complete all as specified and directed.
S & F PVC (SWR) 110 mm junction (Single T) equal or unequal 110mm complete all as specified and directed.
Cutting into existing manhole for connecting new drains and making good to pipes and rendering cutting out existing benching for and forming branching for and forming branch channel (1/2 round or ¼ section ) in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate smooth finished and reforming benching as specified and directed for 100mm dia of pipe complete all as specified.
Dismantling of AC corrugated, semi-corrugated sheets in roof coverings & ridges complete all as specified and directed.
S & F of pre-painted galvalume aluminium zinc coating GI base corrugated steel sheet 0.50 mm thick trapezoidal pattern of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws/L-type or J-type or cranked hook bolts complete all as specified and directed.
Dismantling timber scantling 40 sq cm and over in framed work in any position complete all as specified and directed.
S & F of rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides fixed with angle cleats or other connecting plates conforming to Gde Fe-410 W complete all as specified and as directed.
S & F of vitreous china bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement mortar 1:3 including PTMT waste coupling, PVC waste pipe complete all as specified and directed.
E/M Items :
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credits and making good distrubed surfaces of walls, floors etc complete all as specified and directed.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed.
M&L for point wiring with 1.5 Sq mm single core PVC insulated unsheathed copper FRLSH multi stranded conductor cable in and including Concealed PVC conduit of size 20/25mm ISI marked inclusive of tees ,bend ,elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc with white laminated 3 mm thick hylam sheet cover ISI marked of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sq mm FRLSH cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by Engr-in-charge for following :-
(a) One light point controlled by one, one way switch 5 Amps
(b) One exhaust fan point controlled by one, one way switch 5 Amps
(c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
(d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
ditto all as item no. 81 above as in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.
S & F for Switch Piano type single pole 5 amp, 230 Volts complete all as specified and directed at site.
S & F for Switch Piano type single pole 15 amp, 230 Volts complete all as specified and directed at site.
S & F for socket outlet 2 in 1 , 5 pin, 5 amp, 230 Volts complete all as specified and directed at site.
S & F for socket outlet 2 in 1 , 5 pin, 15 amp, 230 Volts complete all as specified and directed at site.
S & F for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified
S & F for lamp holder , PVC / Polycarbonate type with back plate suitabl for batten/ slanting fittings complete all as specified and directed.
S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for MCB Single pole and neutral rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for Highly efficient LED Bulbs, 10 W, used as a ready replacement for existing GLS/CFL direct fit lamp,in B-22 cap of make Bajaj, Havells, HPL complete all as specified and directed.
Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing LED Bldg sec light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed.
Taking down existing old unserviceable LT UG/ service cable of any description and size complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m in depth of trenches for laying of pipe lines and getting out including forming bottom surfaces to required level complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm all as specified and directed.
Removing excavated material (soil) at a distance n.exc 50m and depositing where directed at a level n.exc 1.5 mtr above the starting point all as specified and directed.
M&L for providing dry sand as in cushioning to underground cable including punning down of sand in layers as specified and directed.
M&L for brick protection cover of UG cable by using old size sub class 'B''common burnt clay building bricks, laid dry and flat abutting each other with width equal to length of the brick and gap between adjacent brick n.exc 10 mm complete all as specified and directed.
S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq. mm 2 core core all as specified and directed.
S&F GI Pipe 40 mm dia light grade for protection of cable complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x6.0 mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0mm dia Protedcted by light GI Pipe 20 mm dia and 15 dia med grade for watering pipe and connected by means of bolts, nuts, check nuts and washers of galvanized iron or steel, iron funnel,Iron pit cover and chamber all as shown in electrical plate No. 3 connected to earthing test point including testing on completion complete all as specified and directed.
Supply, Install, Testing and commissioning of Hot & cold type split air conditioner complete unit with remote, electric driven, single phase 230V, 50Hz with copper pipe duly insulated and electrical cable of suitable size, mounting bracket and all connected required accessories for installation and commissioning with following Specification complete: (a) Capacity - 1.5TR / 4500 K-Cal/Hr (b) Technology - Variable speed dual Inverter Technology (c) Compressor Type - High EER Twin rotary compressor (d) Operating Voltage range - 145V-270V (without stabilizer) (e) Condenser Coil- 100% Copper (f) Star Rating- 5 Star (g Air Filter- Anti dust, anti bacteria
S&F for 3 KVA capacity voltage stablizer, for 1.5 TR inverter type split AC, automatic operation, single phase naturally air cooled, indoor type & designed for input variation betweeen 140 volts to 290 volts, with output volatge stablized at 230 volts with accuracy of +2.5%, and speed og correction 8 volts per second, fixed on wall with necessary fixing arrangements complete all as specified and directed.
Supply, installing steel tubular swaged poles type 410-SP-31 (9 mtr long) with mild steel base plate of size 30cmx30cmx6mm thick, welded at bottom and cap finial taper plugs, bolt, nuts and screw as specified and fixed in true vertical position complete including dismantling of US existing pole by breaking PCC coping and making good as existing ground from site complete as directed by Engr -in-Charge.all as specified and directed. Note :- (a) Earth work and PCC in foundation / coping/padestal shall be measured and paid for separately under respective items. (b) Poles shall be painted with two coats of black bituminous paint throughout internally, and externally upto planting depth. The remaining portion of the exterior surface shall be painted with two coats of aluminium paint over a coat of red oxide primer.
M&L for cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in foundation of pole/stay/strut, filling and mass cocrete etc complete all as specified and directed.
M&L for cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) as in cills, copings, pole pedestals, plinth courses and the like including necessary form work, weathering, slightly rounded or chamfered angles and throating etc complete all as specified and directed.
Supply and fix junction box of PVC type with hinged type door locking arrangement and two Nos suitable mounting clamp of white colour suitable to accomodate one 06 A MCB SP 230 V and incomming & outgoing two cable gland as per requirement size of cable with aluminium bus bar 04 Nos suitable size on insulator fitted in the box all as directed by Engr-in-charge.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp with suitable size bracket and clamp, impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FR cable with stranded copper conductor of size 2.5 Sq mm nominal area and drawing into suitable size of steel conduit with 1.5 Sqmm (nominal area) stranded copper conductor FR cable as earth wire complete all as specified and as directed. Note:- Two runs of 2.5 sqmm cable,one run of 1.5 sqmm cable and one run of steel conduit 19 mm will be measured as one unit.
Note : Tenderers may note that amount of credit Rs 21,054.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
Jain construction co
Pushkar Dutt Bhatt
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .