| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹37.8 L+₹78,655.50 (2.13%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹40.9 L+₹3.9 L (10.5%)Rejected-AOC SARDARPURA 1ST B ROAD NEAR HANUMAN JI KA MANDIR JODHPUR RAJASTHAN 342 003 | JODHPUR | JODHPUR | RAJASTHAN | 342003 | L3 | Rejected-AOC L3 | |
| 4 | L4₹42.3 L+₹5.3 L (14.2%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹42.7 L+₹5.7 L (15.4%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹34.0 L
EMD Value
₹67,960
Closing Date
18 Sept 2023, 6:00 pmClosed
GE (AF) No 02 Jodhpur
GE (AF) No2 Jodhpur
ADDN ALTN TO BATHROOM AND BATHROOM FITTINGS IN MAIN BLOCK OF OFFICER MESS AT AF STN JODHPUR AND SPECIAL REPAIR TO BLDG NO 1389 (SNCOs MESS) AT AF STN JODHPUR
2023_MES_608169_3
8407/E8
Open Tender
Civil Works
Item Rate
60 days
GE (AF) No 02 Jodhpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) No 02 Jodhpur
₹67,960
Yes
9 Nov 2023
1 Sept 2023
20 Sept 2023
1 Sept 2023
18 Sept 2023
12 Sept 2023
1 Sept 2023 - 7 Sept 2023
Amount
Add/Altn to bathroom and bathroom fittings in main block of Officer Mess at AF Stn Jodhpur
Dismantling floor hearth or wall tiling including cement mortar or bedding (but not backing ) removiing serviceable tiles to store and rubbish of the premises
M & L for Glazed ceramic coloured tiles in vertical surface joint free 450x350x7mm thick set and jointed in neat cement slurry and pointed in colour cement to match the surface over and including 10 mm thick plaster in Cm 1:4 complete all as specified and as directed .
M & L for Glazed ceramic coloured tiles in vertical surface (in coloured Border) joint free 350x 250 x 7mm/450x350x7mm thick set and jointed in neat cement slurry and pointed in colour cement to match the surface over and including 10 mm thick plaster in Cm 1:4 complete all as specified and as directed as .
Demolition of cement concrete (unreinforced) in ground floor or paving of any description and in any position not otherwise specifically provided for all as specified.
M&L for 25 mm thick cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub floors finished rough complete all as specified.
M&L Non - skid Ceramic Coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but notexceeding 0.18 sqm, infloors over cement screed bed, 15 mm thick in CM 1:6 for laying floor finishes laid and jointed with grey cement slurry mixed with pigment to match the shed of tile including pointing with coloured cement to match complete all as specified
M&L Non - skid Ceramic Coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but notexceeding 0.38 sqm, infloors over cement screed bed, 15 mm thick in CM 1:6 for laying floor finishes laid and jointed with grey cement slurry mixed with pigment to match the shed of tile including pointing with coloured cement to match complete all as specified
All as per item no 8.00 above but in skirting over 10mm thick rendering 1:4.
Taking down Chowkats or frames but with shutters (without taking off shutters from the frames) n exc. 1.5 sq. m
S&F Powder Coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
M&L 4 mm thick Figured glass, pin head type and glazing with rubber bidding to fix glass in squares n exc 0.5 sq. m in each pane for vantilator
S&F Aluminium Grill for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
S & F in repair 25mm dia stainless steel Stablizer rod heavy grade with brackets to securing toughned glass complete all as specified.
S & F Brass Chrome plated Handle for toughned glass door with brackets to fix & drilled complete all as specified.
Taking up or down galvanised steel water tubing 15mm bore fixed to walls or laid under floors or in any other position alongwith required connetions including cleaning for re-fixing or renewal from site etc complete all as specified.
All as per item No 16.00 here-in-before but 20mm bore.
M & L 15mm bore galvanised steel water tubing medium grade (ISI Marked) with all fittings and cut the wall & fixed complete to walls and or laid under floors etc complete all as specified.
All as per item No 18.00 here-in-before but 20mm bore pipe.
S&F in repair Project Shower Panel 1600X200 mm With Anti Finger Print In Stainless Steel Finish complete all as specified with minimum functions and fittings 1. Head shower 2. Massage jet 3. Hand shower 4. Diverter:4-ways 5. Hot&Cold Faucet 6. Spout, of jaquar series JPL-SSF-ST8896 or same series in equavalent make
Refixing of Vitreous china wash basin (for table top type), white or Coloured, flat back, size 550x400mm including brackets, cutting for and pinning in ends of brackets or erecting stand, brass chromium plated perforated waste coupling/ fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32mm bore and of suitable length, complete all as specified.
S&F in repairs vitreous china wash basin (for table top type), white or Coloured, flat back, size 550x400mm including brackets, cutting for and pinning in ends of brackets or erecting stand, brass chromium plated perforated waste coupling/ fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32mm bore and of suitable length, complete all as specified of make jaquar series JDS-WHT-25907N or same series in other make .
S&F Pillar taps (mixer type for table top whb ), cast copper alloy, fency type with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts,15mm bore of jaquar series KUP-35051BPM or same series in equavalent make with all necesary fittings fix to washbasin
M&L for 20mm thick Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl making round the edge of granite.
S&F in repair Vitreous China EWC, size 710X420X810mm, white or coloured, with floor mounted coupled WC with Soft slim seat cover, Hinges,Sensor & Manual operated single flush cistern & fittings including P/S trap complete all as specified jaquar series LYS-WHT-38851S300UF or same series in equavalent make
S&F in repair Vitreous China Bidget/Urinal, Size 380x605x385mm, white or coloured, with floor mounted with water stopper, waste pvc pipe to drain and all necessary fixtures all as specified jaquar series-SLS-WHT-6153 or same series in equavalent make
S&F in repair Single lever 1-hole bidget mixer Brass chromium plated with Popup waste sustem with 375 mm long braided hoses 2 nos. all as specified jaquar series-OPP-15213BPM or same series in equavalent make
S & F in repair 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified.
S & F in repair extruded aluminum alloy handles fabricated type and anodised of size 150mm complete all as specified.
S&F 250mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S&F UPVC (SWR) floor trap, plain with grating including jointing with solvent cement fixed in cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate for 75 mm out let including taking out old floor trap complete all as specified.
S&F 75mm dia UPVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors
S&F 110mm dia UPVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors
S&F 18mm thick Solid UPVC (WPC) of density not less than 0.60 gm/CM3 decorative face on one faces and other face are white ; fixed with screws to timber frame work as in cabinate approval by Engr-in-charge
S&F Catchable Magnet for cabinate complete all as directed
S & F Auto-hinges, Brass, bright finish complete all as directed
S&F Salt glazed stoneware gully traps of size 150 x 150 mm, square or rounded mouthed, type `P' fixed in CM 1:6 and cover with RCC cover slab of size 200 X 200 X 50mm incl necessary exc, pcc etc.
S&F in repairs, 15 mm bore stop cock/angle cock , fancy type, chromium plated half turn complete all as specified and directed by Engr-in icharge make Jaquar or equavalent
S&F in repairs 15 mm bore bib cock long body fency type with crutch or butterfly handle, cast copper alloy, chromium plated, screwed down, screwed for iron pipe or for brass ferrule make Jaquar or equavalent
S&F Stop valves, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type) screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed 15mm bore make Jaquar or equavalent
S&F Stop valves, cast copper alloy, fancy type, chromium plated with long shank and cup screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed 15mm bore make Jaquar or equavalent
S&F in Repairs 125mm Stainless steel grating (anti-cockroach) with or without waste hole make Jaquar or equavalent approved by Engr-in-charge.
S&F 100 mm size Brass handles, cast type, polished bright for cabinate complete all as directed
S&F in repairs sheet glass shelf 60cm (with brass brackets) consisting of 5.5 mm thick sheet glass with chromium plated bracket guard and railing of jaquar series or same series in equavalent make .
S&F in repairs Corner glass shelf (with brass brackets) consisting of 5.5 mm thick sheet glass with chromium plated bracket guard and railing of jaquar series or same series in equavalent make .
S&F in Repair Brass Health faucet chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and wall hook including making connections and fixed in position complete in all respect as specified of jaquar series-ALD-577 or same series in equavalent make
S&F in repairs Brass chromium plated Soap dish fixed to plugs with chromium plated brass screws Approved by Engr-in-charge of jaquar series-ACN-1131N or same series in equavalent make
S&F Towel Rack 600mm long of Stainless Steel (foldable type) fixed with and including Chromium plated brass screws and wooden/plastic cleats approved by Engr-in-charge of jaquar series or same series in equavalent make
S&F Towel Rail 600mm long of SS fixed with and including Chromium plated brass screws and wooden/plastic cleats approved by Engr-in-charge of jaquar series AQN-7711 or same series in equavalent make
S&F in repair Toilet paper Holder of Stainless Steel with Flap recessed type approved by Engr-in-charge of jaquar series AHS-1553 or same series in equavalent make
S&F 110mm PVC (SWR) junction double, (double T), equal or unequal
S&F 75mm PVC (SWR) junction double, (double T), equal or unequal
S&F 75mm PVC (SWR) bends any radius with access door
S&F 110mm PVC (SWR) vent cowl
Taking down cement plaster in brick walls, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified.
M&L for renderning 15 mm thick in CM 1:4 on stone masonry surfaces finished even and smooth with out using extra cement complete all as specified..
M&L for preparation of new plaster or unplastered surface of walls, applying two coat of OBD over a coat of primer over a thin layer of wall care putty complete all as specified and directed.
M&L for complete removal of existing treatment of wall surfaces by scrubbing with wire brush hard brush, washing down with water, applying two coat of oil bond distemper over a coat of alkali resistant primer over one coat of wall care putty, complete all as specified.
M&L for complete removal of existing treatment of ceiling surfaces by scrubbing with wire brush hard brush, washing down with water, applying two coat of oil bond distemper over a coat of alkali resistant primer over one coat of wall care putty, complete all as specified.
M&L Demolition of Brickwork or stone/ boulder masonry, built in Cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
M&L Squared rubble walling, Jodhpurtype brought uptocourses, well bonded,bedded and solidlyhearted, built in, built in 1:6
Spl repair to Bldg No. 1389 (SNCOs Mess) at AF Stn Jodhpur
Dismantling floor hearth or wall tiling including cement mortar or bedding (but not backing ) removiing serviceable tiles to store and rubbish of the premises
M&L for coloured non skid ceramic tiles of size 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06Sqm but n.exc 0.11 Sqm in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match over 20 mm screed bed in CM 1:6 for lying floor finishes.
M&L for glazed ceramic tiles, coloured, 450x300x7mm thick on vertical surfaces such as skirtings, dados and risers to steps etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 on stone or brick masonry surfaces as directed by Engineer-in-Charge.
M&L for vitrified light coloured and printed tiles of 8 to 10 mm thick (Square/Rectangular) polished area of each tiles not exceeding 0.36 Sqm as in flooring over and including 15 mm thick cement screed in (1:4) CM set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles complete all as specified and directed.
M&L for kota-stone slab 15 mm thick in riser of steps skirting dado skirting and risers to step set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick renedering in CM 1:4 on stone masonary surfaces as directed by Engineer-in-Charge
Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment tomatch the shade of granite stone including grinding and polishing over 20 mm thick Screed bed or bedding layer for laying floor finishes in CM 1:6 completed all as directed by Engineer-in-Charge
Demolition of brick work or stone masonary built in cement mortar complete all as directed.
M&L for Brick work with sub class B bricks straight or curved on plan exc. 6m mean radius built in cement mortar (1:6).complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm each or as directed by Engineer-in-Charge
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqm but not exc 4 sqm each as directed by Engineer-in-Charge
S&F powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
S&F Anodised aluminium powder coating of any color window and ventilator shutter fixed type/sliding type without sash bar, aluminium section weighing 0.55 Kg/m including necessary joining cleats,glazing clips,rubber packing,anodisedaluminium snap beading,screws etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing from site all as specified and directed.
Taking up or down steel tubing 15mm bore and connections including cleaning for refixing or removing from site to store complete as directed by Engineer-in-Charge.
Taking up or down steel tubing 20 mm bore and connections including cleaning for refixing or removing from site to store complete all as specified
Supply and fix 15mm bore galvanized steel tubing "medium grade" with all fittings and fixed complete to walls and ceiling or laid in floor complete all as specified and as directed.
Supply and fix 20 mm bore galvanized steel tubing "medium grade" with all fittings and fixed complete to walls and ceiling or laid in floor complete all as specified and as directed.
M&L for preparation of old painted wooden surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint as directed by Engineer-in-Charge
Demolition of cement concrete (unreinforced) in ground floors and pavings exc. 15 cm thickness (below or above ground level) and removing from site all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for (roof padding, flooring above ground floors) including roof treatment and removing from site all as specified and directed.
M&L for 50 mm thick (average) cement concrete 1:3:6 type C-0 mix (12.5 mm graded stone aggregate) in padding over roof.
M&L for 10 mm thick rendering in CM 1:3 over concrete surfaces (Roof) mixed with water proofing compound @ 3% by weight of cement complete all as specified. NOTE : Water proofing compound shall be measured and paid for separately as “Supply only”
Supply only integral water proofing compound ISI marked.
M&L for complete removal of existing Old App membrane treatment from roof surface complete all as specified and as directed by Engineer-in-Charge.
M&L for applying roof treatment on top of roof with APP modified membrane (minimum 3 mm thick) with non-woven polyster reinforcement/mat (centre core) with thermal insulation with white mineral gravel finish on upper side of membrane laid by torch application method with overlaps 100mm on length side and 100 mm on the width side as per manufacturer’s instructions over and including a coat of approved cold applied bituminous oil based primer (IS- 3384) @ 250 gm/sqm over cleaned roof surface complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for complete removal of existing treatment of plastered or unplastered surfaces of wall and applying two coat of water proof appex paint ( weather coat ) over a coat of primer in any shade or colour as approved by Engr-in-charge complete all as spfd.
Material and Labour for preperation of newly plastered surfaces of wall and applying two coats of Acrlic distemper over 1mm thick wall care putty over a coat of primer complete all as specified and directed by Engr-in-Charge
M & L for three coat of white wash on new surface of ceiling including preparation of new surfaces as directed by Engineer-in-Charge
Dismantling of water tank exc. 250 Litres but not not exc. 500 Litres capacity complete all as specified and directed.
S & F of 500 Litre capacity rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of specifications as per MES Schedule 2009, Part – I and hoisted, fixed in position complete all as specified and directed.
S & F of 20 mm bore ball brass valves, high pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule complete all as specified and directed.
S & F mild steel frame work such as grills, grating framed guard bar with ends of bars shouldered and / or riveted and similar work confirming to Fe-410-0 or Fe-310-0 complete all as specified and directed.
S&F in repairs 20 mm dia gun metal globe or gate valve with iron wheel head screwed both ends for iron pipes as directed by Engineer-in-Charge (Minium weight 15 mm-450 gms)
Taking down carefully copper/aluminum point wiring (Light/ fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, stacking at site for reuse or removing materials to store for keeping in for taking credit and making good the disturbed surfaces / walls/ floors etc,.
M&L for point wiring with 1.5 Sq. mm, multi-stranded copper conductor(FRLSH), single core, PVC insulated and unsheathed cable for phase and neutral, including 1.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly, drawn in surface/concealed conduit heavy duty (HMS Grade), GI terminal boxes not less than 1.0mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover or including modular plates of required size for mounting switch and sockets etc. complete all as specified and directed for following : - Note : Quoted rates deems to be included cost of modular plate for mounting switches, sockets & regulators as required at site. Cutting into chases required for concealing heavy duty (HMS Grade) PVC conduits and making good to damaged surface shall be measured and paid separately under relavant item.
One light / fan point controlled by one switch one way.
One 3 pin 5 Amp switch & socket outlet on same board with other switches.
One 3 pin 5 Amp switch & socket outlet on Independant board.
All same as per item ser No 100.00 here-in-above but wiring using 2.5 sqmm multi-stranded copper conductor FRLSH, single core, PVC insulated and unsheathed cable, including 2.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for 6 pin, 15/16 Amps socket outlet on independant board.
All same as per item ser No 100.00 here-in-above but wiring using 4.0 sqmm multi-stranded copper conductor FRLSH, single core, PVC insulated and unsheathed cable, including 4.0 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for two pin earth metal clad plug & socket point for AC/Geysers.
S&F switch modular single pole one way 6 Amps 230 volt 1 module.
S&F switch modular single pole one way 16 Amps 230 volt 1 module.
S&F Socket modular 6 Amp 2/3 pin combined two module.
S&F Socket modular 6&16 Amp 2/3 pin combined two module.
S&F Stepped type electronic fan regulator, socket size, flush type 230V AC.
S&F Ceiling rose surface bakelite 65x50mm three terminal.
S&F Lamp holder insulated PVC/Polycarbonate/bakelite body, fixed on PVC round or squre box using necessay screw & gutti complete all as specified.
Taking down carefully Ceiling fan/Exhaust fan by disconnecting electrical connections, unsecrewing from position, dismantling blades, stacking carfully at site for reuse of serviceable fans complete all as directed and specified.
Supply and fixing LED light fitting wall /roof mounted, Aluminium housing, 1 x 20 watt including LED tube with driver complete suitable body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 kV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and directed.
Supply and fixing LED light fitting wall /roof mounted, Aluminium housing, 1 x 9/10 watt including LED tube with driver complete suitable body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 kV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and directed.
NOTES FOR LED LIGHT FITTINGS & BULBS : (i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13. (ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80. (iii) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced on site free of cost in the following case :- (a) Manufacturing defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries.
Hanging only ceiling fans, 1200mm sweep, complete with three blade, down rod, accessories and making connection from ceiling rose or connector to fan using three core 0.75sqmm copper stranded conductor PVC insulated and PVC sheathed flexible wire complete all as specified. NOTE: Fan taken down against item No 16 shall be used after complete civil work repair and minor repair of ceiling fans (like replace of rusted nut bolts, denting of blade, cleanig of dust etc)
Fixing only exhaust fan 300mm sweep, Steel/PVC body AC single phase 230V of size 300m using 4 Nos 10mm x 100mm long wall fasteners, nut and washers and connecting up using flexible three core 0.5sqmm copper stranded conductor PVC insulated and PVC sheathed flexible wire through PVC flexible conduit from ceiling rose/connector to fan complete all as specified. NOTE: Exhaust Fan/wall fans taken taken down against item No 16 shall be used after complete civil work repair and minor repair of ceiling fans (like replace of rusted nut bolts, denting of blade, cleanig of dust etc)
M&L for Sub main wiring as per IS, single core FRLS PVC insulated flexible multistranded copper conductor 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unsv submain wiring complete all as specified for Four runs of 6.0 Sq.mm main R-Y-B-N supply cable alongwith two run of single core 6.0 Sq.mm for continuous earth wire in green color. (for OMQ)
Supply and replace sheet metal enclosures with socket plug top, and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 16 Amps, 240 Volt capacity fixed flush to wall surface including making good to damaged surface of wall to match with existing specification and tested on completion complete including taking out old all as directed.
Supply and replace sheet metal enclosure distribution board for 240 volts, 12 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and blank plates and fixed flush in wall surface, and tested on completion complete including taking out old all as directed.
Supply and fix Sheet metal enclosure distribution board TPN, 415 volts, 4 way Horizontal/vertical type as per site requirement, double door type, 200 Amps rated neutral copper bus bar for housing MCBs, blank plates and including provision for fixing TPN MCB as incommer, DB fixed flush or in wall surface including making good to damaged surface of wall to match with existing specification complete including taking out old all as specified all as specified and directed.
M&L for MCB TPN/FP, 63 Amps 415 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
M&L for MCB SPN/DP 40 to 63 Amps 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
Supply and fixing MCB single pole 6-32 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
M&L for wiring with TV coaxial RG-06, electrolytic grade solid annealed copper conductor having single strand of 0.7 mm dia, PVC insulated, aluminium foiled and aluminium wire braided, overall PVC sheathed cable complete including concealed PVC conduit 20mm dia from TV Socket to dish antena on roof of building complete all as specified. Note : 20mm conduit pipe inside building shall be concealed in wall surface and from external surface duly fixed with GI Saddles is deems to be included in quoted rates.
Material and labuor for earthing complete with Galvanized Steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level and filled with 15cm thick alternate layers of charcoal and salt, connected & including GI wire earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron protected by 15mm dia GI Pipe (light grade). Earth plate shall be surrounded by alternate layers of charcoal or coke and common salt in 15cm thick in layers & 15cm of widht all aurround of earth plate including 20mm dia GI light grade pipe for watering and including funnel, wire mesh, necessary earth work in any type of soil, Pre-cast RCC cover duly re inforced with 8mm dia TMT Bar @150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar embedded in cover slab, Earth Pit of PCC (1:3:6) type C2 (using 20mm graded crushed store aggrgate) complete all as specified and as shown in electrical plate No-3 of SSR Part-I including testing on completion. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.
Savitri Enterprises
VIKAS CONSTRUCTION CO.
Sankhla Builders and Construction
M/s Pal Builders
psj build solutions and company
M/S MAJISA CONSTRUCTIONS
M/S JALAL KHAN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .