Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC | ₹1.7 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.9 Cr+₹1.2 Cr (69.6%)Rejected-AOC | ₹2.9 Cr+₹1.2 Cr (69.6%) | L2 | Rejected-AOC L2 |
Tender Value
₹2.5 Cr
EMD Value
₹5.0 L
Closing Date
21 Jun 2023, 6:00 pmClosed
AGM ENGG-ELECTRICAL
AGM ENGG-ELECTRICAL Trichy Airport
Up-gradation of Passenger Terminal Building and Airside Facilities at Trichy International Airport. S.H. Provision of Landscape Lighting for NITB at Trichy Airport
2023_AAI_155489_1
AAI/TRY/E-E/LANDSCAPE/2023
Open Tender
Electrical Works
Item Rate
90 days
AIRPORTS AUTHORITY OF INDIA, TRICHY AIRPORT
Please refer Tender documents.
12 documents required · 12 mandatory
₹1,180
₹5.0 L
6 Sept 2023
31 May 2023
23 Jun 2023
1 Jun 2023
21 Jun 2023
1 Jun 2023
1 Jun 2023 - 8 Jun 2023
Amount
Supply, installation, testing and commissioning of 20W-33W nominal Decorative luminaire (with integral driver) column of height 1100mm and 115mm Dia, with special visual effect created through a smart mix of white and blue sources distributed up and down inside the column. The light fixture (as per the reference pictuers) shall be made of extruded aluminium housing with polyester powder coating and optics cover shall be impact resistance acrylic, stabilized against UV rays, fixture having IP 66, IK08, operating temperature (-10 to +45 degC nominal). Luminaire comprising LEDs of 4000K CCT and Blue colour. LED shall be compliant with useful L70 life of >50,000 Hrs, driver efficiency shall be 85% including proper heat sink for heat dissipation, suitable to operate on input voltage range of 200V to 240V nominal with minimum 4 KV internal surge protection etc., complete as required. (Make: Wipro Schreder Bora Midi or its equivalent similar to the image provided & meeting the technical specifications.) Note: The scope of work covers providing and fixing of suitable loop-in & loop-out polycarbonate junction box having IP-65 including suitable metallic/PVC gland for cable entry & required end terminations complete with all accessories like connectors suitable for connecting the cables, minor civil works, foundation works for fixing the light fixtures, Driver, JB with suitable supports etc., as required inline with tender specifications.
Supply, installation, testing and commissioning of Mono Colour 10W Flood luminaire (with integral driver), Extruded aluminium housing integrated with MC PCB populated with LED and optical lens beam angle (Symmetrical 15 Deg./40 Deg. with 100 lm/w) mounting option of Strap/Spike/Surface, PDC aluminium end caps fixed with silicon gasket to achieve IP66, CRI > 70, SDCM <5, P.F>0.9, Driver efficacy >80, powder coated with pure polyester Eco Gray shade, Toughened clear glass sealed with housing with silicon sealant along with supporting clamp to meet IK06 protection, Constant current IP66 Driver integrated inside of housing etc., complete as required. (Make: Wipro LF39-131-030-30-XX or its equivalent similar to the image provided & meeting the technical specifications.) Note: The scope of work covers providing and fixing of suitable loop-in & loop-out polycarbonate junction box having IP-65 including suitable metallic/PVC gland for cable entry & required end terminations complete with all accessories like connectors suitable for connecting the cables, minor civil works, foundation works for fixing the light fixtures, Driver, JB with suitable supports etc., as required inline with tender specifications.
Supply, installation, testing and commissioning of Mono Colour 20W Flood luminaire (with integral driver), CRI>70, SDCM <5, P.F>0.9, Driver efficacy >80, Extruded aluminium housing integrated with MC PCB populated with LED and optical lens beam angle (Symmetrical 15 Deg./30 Deg/60 deg. with 100 lm/w) mounting option of Strap/ Spike/Surface, PDC aluminium end caps fixed with silicon gasket to achieve IP66, powder coated with pure polyester Eco Gray shade, Toughened clear glass sealed with housing with silicon sealant along with supporting clamp to meet IK06 protection, Constant current IP66 Driver integrated inside of housing etc., complete as required. (make: wipro LF39-271-030-30-XX or its equivalent similar to the image provided & meeting the technical specifications.) Note: The scope of work covers providing and fixing of suitable loop-in & loop-out polycarbonate junction box having IP-65 including suitable metallic/PVC gland for cable entry & required end terminations complete with all accessories like connectors suitable for connecting the cables, civil works, foundation works for fixing the light fixtures, Driver, JB with suitable supports etc., as required inline with tender specifications.
Supply, installation, testing and commissioning of Mono Colour 40W Flood luminaire (with integral driver), CRI>70, SDCM <5, P.F>0.9, Driver efficacy >80, Extruded aluminium housing integrated with MC PCB populated with LED and optical lens beam angle (Symmetrical 15 Deg./30 Deg/60 deg. with 100 LPW) mounting option of Strap/Spike/Surface. PDC aluminium end caps are fixed with silicon gasket to achieve IP66. Luminaire is powder coated with pure polyester Eco Gray shade. Toughened clear glass is sealed with housing with silicon sealant with supporting clamp to meet IK06 protection Constant current IP66 Driver integrated inside of housing etc., complete as required. (make: wipro LF39-521-030-30-XX or its equivalent similar to the image provided & meeting the technical specifications.) Note: The scope of work covers providing and fixing of suitable loop-in & loop-out polycarbonate junction box having IP-65 including suitable metallic/PVC gland for cable entry & required end terminations complete with all accessories like connectors suitable for connecting the cables, civil works, foundation works for fixing the light fixtures, Driver, JB with suitable supports etc., as required inline with tender specifications.
Supply, Installation, testing and commissioning of 12W 3000K LED inground luminaire with System Lumen Output of Minimum 900 Lumen (±10%), CRI > 70, CCT ≥ 3000, driver efficiency ≥ 80%, L70 > 35000 hrs. Min Inground Light die cast aluminium housing integrated with MC PCB populated with LED and optical lens beam angle Symmetrical 15 Deg. / 30 Deg. Fixture shall be made up of Die cast Aluminium Housing for better heat dissipation having IP66 Dust and Water Protection for Outdoor usage mounted on aluminium Die cast Heat Sink. SS ring shall be fixed with a min. 8mm Toughened clear glass with silicon gasket to die cast Heat sink to achieve IP67 ingress protection and meet IK10 protection. Luminaire is powder coated with Polyester TGIC for Heat Sink. The luminaire should have loop in loop out provision for power and DMX Signal. Luminaire should be capable of operating at 24VDC, with External IP66 24Vdc Driver etc., complete as required. (make: wipro LI20-111-30-30-G2 or its equivalent similar to the image provided & meeting the Technical specifications.) Light fixture shall be including of: 1) 06nos. of 120W LED Driver shall be Isolated type, Constant Voltage topology driver in metal enclosure with IP 66 Protection. Output voltage 24Vdc Driver efficiency should be 80% & proper heat sink for heat dissipation suitable to operate in input voltage range of 140V to 270V (nominal rated voltage – 240V) with 4 KV internal surge protection. LED driver shall have out put short circuit & over voltage protection inbuilt. 2) 06nos. of IP 67 Plug-in socket connector (It is 2 core Straight connector used for 3000K luminaires). 3) 41nos. of IP 67 Plug-in socket connector (It is 2 core T connector used for 3000K luminaires). Note: The scope of work covers providing and fixing of suitable loop-in & loop-out polycarbonate junction box having IP-65 including suitable metallic/PVC gland for cable entry & required end terminations complete with all accessories like connectors suitable for connecting the cables,civil works, foundation works for fixing the light fixtures, Driver, JB with suitable supports etc., as required inline with tender specifications.
Supply, Installation, testing and commissioning of 18W Underwater Surface Mounted Device, IP 68, LED underwater light with chrome plated SS powder coated for better heat dissipation. Product comprising LEDs of 3000K CCT. Fixtures should have high purity lenses with glass with 60° Beam, IK10. The LED shall be compliant with useful L70 life of >35000 Hrs. LED Driver shall be Isolated type, with IP 68 Protection. Driver efficiency should be 80% & proper heat sink for heat dissipation suitable to operate in input voltage range of 100V to 300V nominal, power factor > 0.9, with 3 KV internal surge protection etc., complete as required. (make: wipro LU03-211-030-30-XX or its equivalent similar to the image provided & meeting the Technical specifications.) Light fixture shall be including of: 1) 07nos. of 120 W LED Driver shall be Constant Voltage topology driver in metal enclosure with IP 66 Protection. Output voltage 24Vdc LED driver shall have output short circuit & over voltage protection inbuilt. 2) 07nos. of IP 67 Plug-in socket connector (It is 2 core Straight connector used for 3000K luminaires.) 3) 25nos. of IP 67 Plug-in socket connector (It is 2 core T connector used for 3000K luminaires.) Note: The scope of work covers providing and fixing of suitable loop-in & loop-out polycarbonate junction box having IP-65 including suitable metallic/PVC gland for cable entry & required end terminations complete with all accessories like connectors suitable for connecting the cables,civil works, foundation works for fixing the light fixtures, Driver, JB with suitable supports etc., as required inline with tender specifications.
Supply, Installation, testing and commissioning of 18W RGB LED Underwater Surface Mounted Device, IP 68, LED underwater light with chrome plated SS powder coated for better heat dissipation. Product comprising LEDs of RGB CCT. Fixtures should have high purity lenses with glass with 60° Beam, IK10. The LED shall be compliant with useful L70 life of >35000 Hrs. LED Driver shall be Isolated type, with IP 68 Protection. Driver efficiency should be 80% & proper heat sink for heat dissipation suitable to operate in input voltage range of 100V to 300V nominal, power factor > 0.9, with 3 KV internal surge protection etc., complete as required. (make: wipro LU03-211-030-CC-XX or its equivalent similar to the image provided & meeting the Technical specifications.) Light fixture shall be including of: 1) 04nos. of 120 W LED Driver shall be, Constant Voltage topology driver in metal enclosure with IP 66 Protection. Output voltage 24Vdc LED driver shall have output short circuit & over voltage protection inbuilt. 2) 04nos. of IP 67 Plug-in socket connector (It is 2 core Straight connector used for 3000K luminaires.) 3) 08nos. of IP 67 Plug-in socket connector (It is 2 core T connector used for 3000K luminaires.) Note: The scope of work covers providing and fixing of suitable loop-in & loop-out polycarbonate junction box having IP-65 including suitable metallic/PVC gland for cable entry & required end terminations complete with all accessories like connectors suitable for connecting the cables,civil works, foundation works for fixing the light fixtures, Driver, JB with suitable supports etc., as required inline with tender specifications .
Supply, installation, testing and commissioning of 6W to 7.5W LED Step luminaire (with integral driver) Extruded Aluminium Housing IP-66 , IK-07, driver efficiency ≥ 75%, CRI ≥ 70, PF > 0.9, etc., complete as required. (make: wipro LT51-750-XXX-30-XX or its equivalent similar to the image provided & meeting the Technical specifications.) Note: The scope of work covers providing and fixing of suitable loop-in & loop-out polycarbonate junction box having IP-65 including suitable metallic/PVC gland for cable entry & required end terminations complete with all accessories like connectors suitable for connecting the cables, civil works, foundation works for fixing the light fixtures, Driver, JB with suitable supports etc., as required inline with tender specifications.
Providing, laying, fixing, connecting and testing of following sizes of GI strip/GI wire from earth electrode to equipment loop and earthing system, in trenches, on surfaces, along pole or along M.S. support, etc. including excavation where required for laying the copper strip/ GI strip and filling back complete, conforming to relevant IS and all as specified. GI wire 8 SWG
Providing, laying, fixing, connecting and testing of following sizes of GI strip/GI wire from earth electrode to equipment loop and earthing system, in trenches, on surfaces, along pole or along M.S. support, etc. including excavation where required for laying the copper strip/ GI strip and filling back complete, conforming to relevant IS and all as specified. Hot dip GI strip 25mmx 5mm on surface or in recess
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 16205 complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling earthwork, and protective covering etc., complete as required. 63 mm dia. (OD-63 mm & ID-51 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 16205 Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling earthwork, and protective covering etc., complete as required. 90 mm dia. (OD-90 mm & ID-76 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 16205 Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling earthwork, and protective covering etc., complete as required. 120 mm dia. (OD-120 mm & ID-103 mm nominal)
LT CABLES & CABLE LAYING Supply of following size of 1.1 KV grade FRLS multicore aluminium conductor XLPE insulated and PVC extruded sheathed armoured cable as per IS: 7098:1988 (Part-I) with upto date amendments etc., as required. 3½ core X 120 Sq.mm Al.
Supply of following size of 1.1 KV grade FRLS multicore aluminium conductor XLPE insulated and PVC sheathed extruded armoured cable as per IS: 7098:1988 (Part-I) with upto date amendments etc., as required. 4 core X 25 Sq.mm Al.
Supply of following size of 1.1 KV grade FRLS multicore copper conductor XLPE insulated and PVC sheathed extruded armoured cable as per IS: 7098:1988 (Part-I) with upto date amendments etc., as required. 4 core X 4 Sq.mm Cu.
Supply of following size of 1.1 KV grade FRLS multicore copper conductor XLPE insulated and PVC sheathed extruded armoured cable as per IS: 7098:1988 (Part-I) with upto date amendments etc., as required. 4 core X 6 Sq.mm Cu.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on existing cable tray as required. Tagging on both the ends will be done with aluminium tags etc. complete as required. (Cable in cable tray shall be clamped with 1mm thick saddle) Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on existing cable tray as required. Tagging on both the ends will be done with aluminium tags etc. complete as required. (Cable in cable tray shall be clamped with 1mm thick saddle) Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ STONEWARE/ METAL/ DWC HDPE pipe etc. complete as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ STONEWARE/ METAL/ DWC HDPE pipe etc. complete as required. Above 95 sq. mm and upto 185 sq. mm
Supplying and making indoor end termination with brass single compression gland (Heavy duty type) and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor armoured cable of 1.1 KV grade as required. 3½ core X 120 Sq.mm Al.
Supplying and making indoor end termination with brass single compression gland (Heavy duty type) and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor armoured cable of 1.1 KV grade as required. 4 core X 25 Sq.mm Al.
Supplying and making indoor end termination with brass single compression gland (Heavy duty type) and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor armoured cable of 1.1 KV grade as required. 4core X 4 Sq.mm Cu.
Supplying and making indoor end termination with brass single compression gland (Heavy duty type) and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor armoured cable of 1.1 KV grade as required. 4 core X 6 Sq.mm Cu.
Supplying and fixing 32 A, 415 V, TPN Industrial type socket outlet (IP-65), with 3 pole and earth, plug top along with 63 A, 10 kA MCB in IP-65, IK-08 Polycarbonate enclosure with cover for the socket outlet and complete with connections, testing and commissioning etc. including 1.25 Mtr. MS 'C' class stand post of suitable dia. (minimum 50 mm) including civil foundation work (PCC) complete in all respect etc., as required.
Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design: Inside size 100 x 100 cm and 100 cm deep including RCC cover with frame (heavy duty). With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Supply and fixing of 17.2 mm Copper bonded BIS certified rod of 3 Mtr length complete environment friendly, RoHS certified, low resistivity Ground enhancement material in 22.6 Kg pack, including pit cover, clamping arrangements to fill the bore area around the rod complete in all respect etc., as required as per technical specifications.
Providing, laying and fixing of following dia. R.C.C. pipe NP3 class complete with R.C.C. collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) for road crossings including excavation and refilling etc. complete as required. 150 mm
Making Horizontal boring by suitable mechanical arrangment, Sensor operated, Min 2.5 mts depth, horizontal borewell suitable for inserting 01no 160mm dia HDPE pipe, job including inserting of HDPE pipe in bore well hole, but welding etc., complete as per site requirment.
Supply of 160mm dia size HDPE pipe, ISI marked along with all accessories like socket, couplers etc. conforming to IS 4984-1995, NP6 grade, PE63 etc., complete as required.
Providing and fixing flow solar studs of size 125 x 125 x 20 mm made of heavy duty body of moulded Aluminium Alloy and High Impact Polystyrene/Polycarbonate having electronically welded micro-prismatic lens with abrasion resistant coating as approved by Engineer in Charge. The glow stud shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro reflective surface shall be 35 (+/-5) degree to base. The illuminated panels on both sides with at least 12 cm of illuminating area up each side. It shall be tested as described in ASTM I: 809 as recommended in BS: 873 part 4:1973. The studs shall be fixed to the road surface using the adhesive confirming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineering In Charge.
BUDHIRAJA ELECTRICALS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .