Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC | ₹6.0 L Quoted ₹6.2 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹6.7 L+₹47,150 (7.62%)Rejected-Finance 38 30 92 SAI NAGAR MARRIPALEM VISAKHAPATNAM 530 018 | VISAKHAPATANAM | ANDHRA PRADESH | 530018 | ₹6.7 L+₹47,150 (7.62%) | L2 | Rejected-Finance Being not L1 |
| 3 | L3₹6.9 L+₹70,580 (11.4%)Rejected-Finance DOOR NO 57 28 10 4 2 BHAVANI GARDENS INDUSTRIAL ESTATE POST VISAKHAPATNAM 530 007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | ₹6.9 L+₹70,580 (11.4%) | L3 | Rejected-Finance Being not L1 |
| 4 | L4₹6.9 L+₹73,060 (11.8%)Rejected-Finance DOOR NO 44 19 10 RAILWAY NEW COLONY BEHIND SIVALAYAM VISAKHAPATNAM AP 530016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | ₹6.9 L+₹73,060 (11.8%) | L4 | Rejected-Finance Being not L1 |
| 5 | L5₹6.9 L+₹75,515 (12.2%)Rejected-Finance 21 167 KAKANI NAGAR 2ND LANE NAD POST VISAKHAPATNAM 530009 | VISAKHAPATANAM | ANDHRA PRADESH | 530009 | ₹6.9 L+₹75,515 (12.2%) | L5 | Rejected-Finance Being not L1 |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
29 Apr 2022, 6:00 pmClosed
Shri Nitesh K Singh, IDSE AEE AGE (I) R and D NSTL
AGE (I) R and D, NSTL Complex, Visakhapatnam 530027
8377 REPAIR / REPLACEMENT OF UNSERVICEABLE STREET LIGHT, SECURITY LIGHT, POLE PAINTING, JUNCTION BOXES, DAMAGED CABLES AND CONNECTED WORKS AT NSTL TECH AREA UNDER AGE (I) RnD NSTL, VISAKHAPATNAM.
2022_MES_517356_1
AGE I R AND D NSTL VIZAG 8377
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Visakhapatnam
Class E Category b (i)
7 documents required · 7 mandatory
₹500
AGE I R and D NSTL Visakhapatnam
₹18,000
Yes
1 Jul 2022
8 Apr 2022
2 May 2022
8 Apr 2022
29 Apr 2022
22 Apr 2022
Amount
Supply and fixing, connecting up and testing 120 W High efficient LED flood light fitting with aluminium pressure die-cast housing, High powered LEDs andf secondary lenses with IP66 protection, Toughened glass with silicon gaskets complete including taking down existing unserviceable light fitting. [Make: Crompton, Cat No: LFLN-120-CDL/60-M or equivalent in Wipro/ Havells/ Philips]
Supply, fixing, connecting up and testing 150 W High efficient LED flood light fitting with aluminium pressure die-cast housing, High powered LEDs and secondary lenses with IP66 protection, Toughened glass with silicon gaskets complete including taking down existing unserviceable light fitting. [Make: Crompton, Cat No: LFLN-150-CDL/60-M or equivalent in Wipro/ Havells/ Philips]
Supply, fixing, connecting up and testing 30 W High efficient LED security light fitting with aluminium pressure die-cast housing, High powered LEDs and secondary lenses with IP-65 protection complete including taking down existing unserviceable light fitting. [Make: Crompton, Cat No: LSTS-30-CDL-M or equivalent in Wipro/ Havells/ Philips]
Supply, fixing, connecting up and testing 45 W High efficient LED security light fitting with aluminium pressure die-cast housing, High powered LEDs and secondary lenses with IP-65 protection complete including taking down existing unserviceable light fitting. [Make: Crompton, Cat No: LSTS-45-CDL-M or equivalent in Wipro/ Havells/ Philips]
Supply and install LED post top lantern, 20W, IP 65 protection complete including necessary cable connection all as specified and directed including taking down existing unserviceable fitting. [Cat No. LPTH-20-CDL of make: Crompton or Techno-commercially equivalent in Bajaj/ Wipro/ Havells/ Philips]
Disconnecting & taking down unserviceable MS Box and S&F pole mounted PVC junction box one piece moulded SMS base and SMC door fixed with hinges on left side of size 280x170x130 mm outside and 240x130x110 mm inside of off white colour (Make -Sintex including one No SP MCB of 6 Amp cap and neutral link and necessary fixing arrangement)
S&F in replacement of LED street light driver of 25/30 Watt 230 V 50Hz suitable for operation on voltage range of 140 V to 270 V by removing from existing position complete all as specified and as directed by Engineer-in-Charge. [Make: Philips/ Wipro/ CG/ Havells/ Bajaj] Note: (i) T& P required for carrying out repair work on street lights at a height up to 15 mtr will be arranged by the contractor and cost of the same deemed to be included in quoted rate (ii) Contractor is bound to provide material to match the technical specification of LED fittings and to suit to be fixed in the casing of LED fittings
All as per item No. 7 herein before but of capacity 45 Watts
S&F in replacement of LED flood light driver of 120/150 Watt 230 V 50Hz suitable for operation on voltage range of 140 V to 270 V by removing from existing position complete all as specified and as directed by Engineer-in-Charge. [Make: Philips/ Wipro/ CG/ Havells/ Bajaj] Note: (i) T& P required for carrying out repair work on street lights at a height up to 15 mtr will be arranged by the contractor and cost of the same deemed to be included in quoted rate (ii) Contractor is bound to provide material to match the technical specification of LED fittings and to suit to be fixed in the casing of LED fittings
S&F in replacement of Surge Protection Devices of 10KV compatible with industrial & outdoor LED fixtures of by removing from existing position complete all as specified and as directed by Engineer-in-Charge. [Make: Philips/ Wipro/ CG/ Havells/ Bajaj] Note: (i) T& P required for carrying out repair work will be arranged by the contractor and cost of the same deemed to be included in quoted rate (ii) Contractor is bound to provide material to match the technical specification of LED fittings and to suit to be fixed in the casing of LED fittings
Trimming the branches of tree/ bushes touching the electric conductor and around the street light fitting upto 1.5 mtr radius and removing the same from site cleaning and depositing where directed complete all as specified and as directed by Engg-in-Charge. Note :- Any damage caused to the infrastructure during trimming shall be made good by the contractor without any extra cost.
Disconnection & taking down the unserviceable GI bracket of size 40mm dia from the pole / building and M&L for street light bracket made out of 40 mm dia GI tubing medium grade upto 1.5 mtr long including bending, welding ,drilling holes as required and fixing with flat iron clamps 50x 6 mm thick (02 Nos) with suitable nut, bolts and washers to steel tubular /concrete poles complete, including preparation of steel and iron surface and applying two coats of aluminium paint, first quality, over a coat of primer, etc complete, all as specified and as directed. Make of GI Pipe:- Jindal / Zenith / Prakash and Make of paint:- Asian / Berger / Jenson & Nicholson.
All as per item No 12 here-in-above but of capacity 25mm dia GI tubing
M & L for PCC 1:3:6 type C-2 (40 mm graded aggregate) for pole foundation complete all as directed
M & L for PCC 1:2:4 type B-1 (20 mm graded aggregate) for pole coping complete all as directed
Supply and fix NATURE SWITCH in replacement of Analog Timer switch of capacity 230 volts, Max Load 3-5 KW, 25 Amps rating, single phase, model: SWADEEP-02EC-3KW1P for Automatic Switching ON/ OFF along with Contactors, MCBs and eclosures with complete control wiring complete all as specified and as directed. Make: Healer or equivalent in Bajaj/ Kakatiya energy systems
M & L for Preparation of old painted surface of electric poles mild steel tubular type 9 long any type /make/model above ground level including cross arms clamps etc and applying two coats with aluminium paint on pole , cross arms, clamps , brackets etc including zebra painting for PCC/ Steel poles 9/11 mtr long upto 1.5 mtr height from ground level with two coats of enamel synthetic paint in 30 CM height of alternate band including painting of pole coping writing pole No all as specified and directed by Engineer in /charge. Make of paint : Berger/Asian/ Nerolac
Taking up existing LT XLPE/ PVC UG cable 1100 V grade, 3½/ 4 core of size 16 Sq.mm to 25 Sq.mm from the trenches along with cable protection covers/ bricks, sand carefully for finding out the fault complete all as directed by Engineer-in-Charge Notes: (a) Excavation to expose cable covers/ sand cushion will be measured and paid separately.
Supply, lay, connect, test and commissioning of LT XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade of size 3.5 Core 25 Sq.mm complete all as specified and directed.
All as per Item No. 24 here-in before but of size 16 Sq.mm 4 core
Taking up old unsv cable and Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty 6 sq. mm 2 core cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed.
Relaying of old serviceable LT XLPE UG cable 1100V grade of any size after fault rectification complete all as directed by Engineer-in-Charge Note: Excavation & earth work will be measured and paid separately.
Supply and laying GI pipe of 50mm bore dia light grade for cable protection, laid in trenches for drawing cables complete all as specified and as directed. [Make: Tata/ Jindal/ Zenith]
Cutting trench of width 30cm and depth n.exc. 60cm through road/ hard standing for laying cable through GI pipe and returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm after laying the cable complete including provision of PCC type B1 filling for top 100mm layer all as directed.
Excavating in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n. exc. 10sq.m. on plan and n. exc. 1.5m in depth and getting out in hard/ dense soil.
Returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm in any type of soil.
Removing excavated materials to a distance not exc. 50m and depositing where directed at a level n.exc 1.50m above the starting point.
Supply & lay precast cable cover class LV, type 1, flat of size 250x150x40mm for cable protection all as specified
Supply and spread river sand as in cushioning for UG cable all as specified in clause 19.75 of SSR Part I. [Note: Punned down thickness shall be considered for payment]
M & L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick buried directly in gorund earth pit not less than 2.25 m deep below normal ground level with the top edge of earth plate at a depth of not less than 1.5 m below normal ground level connected to using galvanised iron strip 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers made out of GI pipe as well as 20mm dia medium grade pipe 1.5 mtr fixed with funnel and wire mesh as specified and connected all as shown in electrical plate No 3 of SSR Part I including necessary earth work and excacation in any type of soil anbd PCC1 : 2: 4 type B-1 in chamber and 40 mm thick RCC 1 : 2 : 4 type B-1 cover slab with 6mm dia mild steel bars at 100mm centre to cenre both ways with 6mm dia M S hooks complete all as specified.
ANJALI CONSTRUCTIONS
B SRINIVAS
ANJALI ENTERPRISES
SVG SUPPLIES
ANJANA ENTERPRISES
R AND A ASSOCIATES ENGINEERS CONTRACTORS
suresh electricals
DPS sales and services india
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .