| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.3 LAccepted-AOC | ₹41.3 L Quoted ₹41.7 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹44.0 L+₹2.2 L (5.33%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | ₹44.0 L+₹2.2 L (5.33%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹44.5 L+₹2.8 L (6.67%)Rejected-Finance C O BHAGYODAY STORES BAZAR CHOWK NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | ₹44.5 L+₹2.8 L (6.67%) | L3 | Rejected-Finance Being L3 |
| 4 | L4₹45.3 L+₹3.6 L (8.53%)Rejected-Finance KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | ₹45.3 L+₹3.6 L (8.53%) | L4 | Rejected-Finance Being L4 |
| 5 | L5₹45.8 L+₹4.1 L (9.74%)Rejected-Finance | ₹45.8 L+₹4.1 L (9.74%) | L5 | Rejected-Finance Being L5 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
20 Jan 2024, 6:00 pmClosed
LT COL UTKARSH SHARMA
OPP BIRLA FACTORY GE (I) CG PORBANDAR
SPECIAL REPAIR TO BUILDING No. P-20 AT ICGS VADINAR UNDER GE(I) CG PORBANDAR
2023_MES_635042_1
8965/E8
Open Tender
Civil Works
Item Rate
180 days
VADINAR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE I CG PORBANDAR
₹84,000
Yes
26 Feb 2024
30 Dec 2023
22 Jan 2024
30 Dec 2023
20 Jan 2024
15 Jan 2024
Amount
SCHEDULE 'A' B/R ITEMS
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises, Complete all as specified & directed by Engineer-in-Charge.
Material & Labour for PCC 1:2:4 type B-0 (using 12.50mm graded stone aggregate) 40mm thick as in sub base to receive tiles, Complete all as specified & directed by Engineer-in-Charge.
Material & Labour for Non - skid Ceramic tiles 10mm thick (square/ rectangular) area of each tile exceeding 1.00 sqm but not exceeding 2.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 20mm screed bed or bedding layer in 1:4 Cement Mortar, Complete all as specified & directed by Engineer-in-Charge.
Material & Labour for Glazed Ceramic tiles 10mm thick (square/ rectangular) area of each tile exceeding 1.00 sqm but not exceeding 2.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 20mm screed bed or bedding layer in 1:4 Cement Mortar, Complete all as specified & directed by Engineer-in-Charge.
Material & Labour for Glazed ceramic tiles in vertical surface 1800x 600x 10 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match, including 10mm thick screed bed or bedding layer in 1:4 Cement Mortar as in skirting, dados & vertical surface, Complete all as specified & directed by Engineer-in-Charge.
Material & Labour for Exterior floor tiles 16-18 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 20mm thick screed bed or bedding layer with 1:6 cement Mortar, Complete all as specified & directed by Engineer-in-Charge.
Material & Labour granite (of any type) tiles 20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding, moulding the edges and polishing over backing coat of 10mm thick in cement mortar 1:4 for laying dadoo & skirting finishes, Complete all as specified & directed by Engineer-in-Charge.
Demolition of brick and stone wall built in cement mortor including all quoins, arches, pillars built in cement mortar, Complete all as specified & directed by Engineer-in-Charge.
Material & Labour for Pre-cast cement concrete block masonary type C-1, 1:3:6 (20mm graded stone aggregate) with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:4, Complete all as specified & directed by Engineer-in-Charge.
Taking down cement plaster on stone wall including racking out joints, hacking for key scrubbing with water etc., Complete all as specified & directed by Engineer-in-Charge.
Material & Labour for rendering 5mm thick on ceiling concrete surfaces in cement mortar 1:4 and even and smooth without using extra cement, Complete all as specified & directed by Engineer-in-Charge.
Material & Labour for rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4 and even and smooth without using extra cement, Complete all as specified & directed by Engineer-in-Charge.
Material & Labour for rendering 10mm thick in cement mortor 1:6 on brick / concrete surfaces, finished even and smooth without using extra cement, Complete all as specified & directed by Engineer-in-Charge.
Material & Labour for granules textured homogeneous wall finishing system consisting of a two component system of dry granules (25 Kg per Pack) made of 92% silica particles coated with fade resistant pigment, 100% acrylic polymer bonding agent (5 Kg per pack) with the applied thickness of the coating being between 0.8mm -1.2mm to be applied on curved, smooth level plaster without key, as per manufacture directions, for usages to be applied and approved applicator of the manufacture as per the direction/ supervision of the Engineer-in-charge, all complete. The above textured coating should conform to surface spread of flame class one of BS 476:Part 7:1971 and pull off strength of the coating to meet JISA 6909 on smooth plastered surfaces, Complete all as specified & directed by Engineer-in-Charge. Make:- Bakelite Hylam Limited or equivalent make approved by the GE.
Material & Labour for Preparing new surfaces of walls by washing rubbing down and stopping of distempered and painted surfaces and applying two coat of distemper oil emulsion over one coat of chalk putty, Complete all as specified & directed by Engineer-in-Charge.
Dismantling water tanks exceeding 500 Litres and not exceeding 1000 Litres and removing to store, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing 1000 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore ball brass valves, high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed, Complete all as specified & directed by Engineer-in-Charge.
Taking up or down 15mm steel tubing and connections or removal to store, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing 20mm outer dia of pipe 3-layer PP-R polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV Stabilised and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plian & brass threated polypropylene random fittings fixed complete to walls, ceiling or in floors etc., Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing in repair vanitee cabinate of overall size 0.90 mtr x 1.70mtr with one nos of mirror having size 0.75mtr x 0.80 mtr , one wash basin of size 0.50 x 0.30 mtrs,with one wash basin mixture of approved shade and size, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing in repair shower enclosure having overall size 1.2 mtr x 1mtr x 2.10 mtr height with 8-12mm thick glass with sliding door arrangements etc., Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing in repair shower panels with over head shower, hand shower, mixing arrangements for hot and cold water etc., Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing in repair Ceramic white colour EWC with seat cover and dual flush tank, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing in repairs 15mm dia CP bib tap of brass type cast copper alloy with crutch or butterfly handle fixed pipe, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing in repair 15mm bore stop valves, cast copper alloyfancy type screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing in repair stainless steel towel rack with lower hangers 60cm long fixed, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing in repair 15mm dia two way bib cock, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing in repair 15mm dia Health Faucet with 1mtr long lead fixed in pipe, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing in repair superior quality towel ring of 150mm dia, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing in repair toilet roll paper holder with stainless steel flap, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing in repair soap dish holder with flap, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing in repair Glass shelves 550mm long, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing in repair Grating doom 100mm dia of PTMT (Minimum weight 25gms), Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing in repair PVC connections 15 mm size with PTMT nuts of length 600 mm, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing in repair PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm dia fixed, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing PVC (SWR) bends any radius 110mm dia, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing 12mm thick toughened frosted float glass including rounding to edges for partaion or door, Complete all as specified & directed by Engineer-in-Charge.
Taking down chowkat with shutters (without taking of shutters from the frames of any description not exceeding 1.5 Sqm in each panel, Complete all as specified & directed by Engineer-in-Charge.
Taking down chowkat but shutters (without taking of shutters from the frames of any description exceeding 1.5 Sqm but not exceeding 4.0 Sqm in each panel, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing of 2nd class HW plain chowkhats and framed,rebated on the solid rounded or chamfered put together with glue pinned at joints, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing 40mm thick Flush Shutter, solid core construction, with block board core and plywood face panels, both face is covered with decorative face veneer with lipping/ frame to match commercial type on both side, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing 100mm long medium weight, cold rolled mild steel Butt hinges and fixed, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing 150mm long Extruded Aluminium alloy handles, fabricated type, anodised, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing 150mm long Aluminium, anodised, barrel tower bolts of extruded section, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (±0.2mm). Window profile with hollow section with multi chamber, frame (88mm x 52mm), sliding sash (42mm x 67mm), sliding interlock (one vertical length in each shutter) (45.5mm x 28mm), glazing bead (24.5mm x 16mm) will be mitered cut and fusion welded at all corners, including railing of holes for fixing hardware and drainage of water ets, making arrangement for fixing of hardware, EPDM gasket. 1.2 ±0.2mm thick galvanized steel frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm) 2nos, sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100m long fastener. Hardware (touch lock of zinc alloyed (white powder coated), steel roller system, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories, Complete all as specified & directed by Engineer-in-Charge. Note: The unit rate excludes cost of glass and includes all other connected accessories area not exceeding 2.0 Sqm each.
Supply & Fixing 7mm thick aluminium grills of make "Decogrill" model DG 104 surrounded by aluminum 'C' channel and size of opening 75x75 mm, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing 20mm dia., double hook Aluminium alloy anodised curtain rails with brackets, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing in repair aluminium body Door closer hydraulically regulated,designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed to aluminium door, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, Complete all as specified & directed by Engineer-in-Charge.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets etc., Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing size of grid 605mm x 605mm GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20mm and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exceeding 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long, Complete all as specified & directed by Engineer-in-Charge.
Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions, Complete all as specified & directed by Engineer-in-Charge.
Ditto-all as per ser Item No. 56.00 but to curved surface, Complete all as specified & directed by Engineer-in-Charge.
Material & Labour for preparation of ceiling surfaces and applying two coat of oil bound distemper over a coat of primer, Complete all as specified & directed by Engineer-in-Charge.
Demolition of reinforced cement concrete of any description and in any position not other wise specifically provided for like manhole covers, kitchen shleves etc upto 2nd floor, Complete all as specified & directed by Engineer-in-Charge.
Material & Labour for cement concrete Type B-0 1:2:4 (12.5mm graded aggregate) for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves including necessary form work, Complete all as specified & directed by Engineer-in-Charge.
Material & Labour for mild steel TMT bars 10mm dia and over , cut to length, bent shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing in repair wall panelling made up of UPVC foam profile with homogenous fine cellular structure having smooth outer intergral skin having 100mm wide tounge and groove design with 10mm thickness of required shade, the internal batten having 35mm width and 17mm thickness, The batten aligned horizontally along the wall with 50mm gap above the floor and below the ceiling. The internal batten shall be fixed 450mm centre to centre in between junction and corners should be covered with foam beading profiles including providing 17mm thick EPS Sheet as insulation and better rigidity of wall panelling between wall and paneling, Complete all as specified & directed by Engineer-in-Charge.
Dismantling mild steel work of any description not otherwise provided for Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing framed work such as grills, gratings, etc with ends of bars shouldered and/or revited, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work confirming to Fe.290. Gde-E-165, Complete all as specified & directed by Engineer-in-Charge.
Material & Labour for preparation of new steel surfaces of any description over 10cm width or girth apply two coats of synthetic enamel painting over one coat of red oxide primer, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing in repair sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete with waste coupling and waste pipes of suitable capacity, Complete all as specified & directed by Engineer-in-Charge.
Demolition Cement Concrete of any description and in any position not otherwise specifically provided for Drain cover, manhole cover, Beam, Slab & etc., Complete all as specified & directed by Engineer-in-Charge.
Material & Labour hardcore of guage not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, Complete all as specified & directed by Engineer-in-Charge.
Material & Labour for sand filling under floor or in foundations including watering and consolidation, Complete all as specified & directed by Engineer-in-Charge.
Material & Labour for machine pressed precast concrete interlocking paver blocks any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Gde with grey cement and pigment, Complete all as specified & directed by Engineer-in-Charge.
Material & Labour for precast cement concrete Type B-0 (1:2:4) (using 12.5 mm graded aggregate), 40mm thick Jali, including all moulding set in Cement Mortar 1:4, Complete all as specified & directed by Engineer-in-Charge.
Dismantling boarding, any description, fixed in any position with nails, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing in repair 1.5mm thick Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions on 18mm thick calibrated plywood of grade BWR, type BB, fixed with screws to timber frame work, Complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing in repair Continuous (Piano) hinges, mild steel, bright finished or electro galvanized, width of flaps (When open) 30mm, Complete all as specified & directed by Engineer-in-Charge.
SCHEDULE 'A' E/M ITEMS
Taking down the sub main wiring of any dia / Sqmm on teak wood batten / PVC conduit GI earth wire, Complete all as specified & directed by Engineer-in-Charge.
Taking down the existing point wiring of aluminium/copper for Light, fan, Sockets, power sockets, stair case light point complete with switch socket regulator , bracket fitting etc and making good disturbed surfaces for wall, floors etc., Complete all as specified & directed by Engineer-in-Charge.
Taking down Ceiling fan, cealing cable and dismantling blades and removing fan and blade to store for safe custody and re-hanging the same after servicing and painting of ceiling fan complete in situ with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc and connecting up including provision of cable from ceiling rose, Complete all as specified & directed by Engineer-in-Charge.
Taking down geyser 25 Ltr, connection cable and to store for safe custody and re-hanging the same after servicing complete in situ and connecting up including provision of cable, Complete all as specified & directed by Engineer-in-Charge.
Material & Labour for Point wiring complete with 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sqmm PVC insulated but unsheathed multi stranded copper conductor FRLS cable as earth continuity wire for modular wiring, Complete all as specified & directed by Engineer-in-Charge. for the following:- Make of cable:- Havells/ Finolex/ RR Kable/ KEI
All as per Ser Item No. 80.00 But One light point /fan point controlled by one switch with cable 1.5 Sqmm nominal area
All as per Ser Item No. 80.00 But one 3 pin socket outlet 5 Amps on the same board with other switches with cable of size 1.5 Sqmm nominal area
All as per Ser Item No. 80.00 But one 3 pin socket outlet 5 Amps independent board with cable 1.5 Sqmm nominal area
All as per Ser Item No. 80.00 But One bell point controlled by one bell switch with cable 1.5 Sqmm Sqmm nominal area
Material & Labour for Point wiring complete with 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 Volts grade drawn through and including PVC heavy duty conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 2.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire, Complete all as specified & directed by Engineer-in-Charge. for the following:- Make of cable:- Havells/ Finolex/ RR Kable/ KEI (a) one 3/5 pin 15/16 Amps socket
Supply & Fixing in replacement of Modular switch 1 way, 10 Amps, 1 module in black colour, Complete all as specified & directed by Engineer-in-Charge. Make:- Legrand / Schneider / hager/Anchor(Panasonic)/Anchor(Roma)
Supply & Fixing in replacement of Modular switch 1 way, 16 Amps, 1 module in black colour, Complete all as specified & directed by Engineer-in-Charge. Make:- Legrand / Schneider / hager/Anchor(Panasonic)/Anchor(Roma)
Supply & Fixing in replacement of Modular socket, 6 Amps, 2/3 pin combined 2 module in black colour, Complete all as specified & directed by Engineer-in-Charge. Make:- Legrand / Schneider / hager/Anchor(Panasonic)/Anchor(Roma)
Supply & Fixing in replacement of Modular socket, 6/16 Amps, 2/3 pin combined 2 module in black colour, Complete all as specified & directed by Engineer-in-Charge. Make: Legrand / Schneider / hager/Anchor(Panasonic)/Anchor(Roma)
Supply & Fixing in replacement of Modular Bell push 6A 1 module in black colour, Complete all as specified & directed by Engineer-in-Charge. Make: Legrand / Schneider / hager/Anchor(Panasonic)/Anchor(Roma)
Supply & Fixing in replacement of Bell, Ding Dong AC. 230 volts, single pole, Complete all as specified & directed by Engineer-in-Charge. Make: Legrand / Schneider / hager/Anchor(Panasonic)/Anchor(Roma)
Supply & Fixing in replacement of Modular fan regulator, 120 watt, 2 module in black colour (ISI marked), Complete all as specified & directed by Engineer-in-Charge. Make: Legrand / Schneider / hager/Anchor(Panasonic)/Anchor(Roma)
Supply & Fixing in replacement of Modular 32 Amp Switch 1 way with indicator, 2 module in black colour (ISI marked), Complete all as specified & directed by Engineer-in-Charge. Make: Legrand / Schneider / hager/Anchor(Panasonic)/Anchor(Roma)
Supply & Fixing 6 Amp, 250 V high quality robust surface/ flush type polycarbonate/ PVC ceiling rose, conforming to IS: 371- 1979, having 2/3 terminals and outside diameter not less than 63.5 mm, Complete all as specified & directed by Engineer-in-Charge. Make: Anchor/Crabtree/Cona
Supply & fixing modular metal flush box 1 module ISI marked), Complete all as specified & directed by Engineer-in-Charge. Make: Legrand / Schneider / hager/Anchor(Panasonic)/Anchor(Roma)
Supply & fixing modular metal flush box 2 module ISI marked), Complete all as specified & directed by Engineer-in-Charge. Make: Legrand / Schneider / hager/Anchor(Panasonic)/Anchor(Roma)
Supply & fixing modular metal flush box 3 module ISI marked), Complete all as specified & directed by Engineer-in-Charge. Make: Legrand / Schneider / hager/Anchor(Panasonic)/Anchor(Roma)
Supply & fixing modular metal flush box 4 module ISI marked), Complete all as specified & directed by Engineer-in-Charge. Make: Legrand / Schneider / hager/Anchor(Panasonic)/Anchor(Roma)
Supply & fixing modular metal flush box 8 module ISI marked), Complete all as specified & directed by Engineer-in-Charge. Make: Legrand / Schneider / hager/Anchor(Panasonic)/Anchor(Roma)
Supply & fixing modular metal flush box 12 module ISI marked), Complete all as specified & directed by Engineer-in-Charge. Make: Legrand / Schneider / hager/Anchor(Panasonic)/Anchor(Roma)
Supply & fixing modular metal flush box 18 module ISI marked), Complete all as specified & directed by Engineer-in-Charge. Make: Legrand / Schneider / hager/Anchor(Panasonic)/Anchor(Roma)
Supply & fixing modular cover plate with frame (Black colour), 1 module (ISI marked), Complete all as specified & directed by Engineer-in-Charge. Make: Legrand / Schneider / hager/Anchor(Panasonic)/Anchor(Roma)
Supply & fixing modular cover plate with frame (Black colour), 2 module (ISI marked), Complete all as specified & directed by Engineer-in-Charge. Make: Legrand / Schneider / hager/Anchor(Panasonic)/Anchor(Roma)
Supply & fixing modular cover plate with frame (Black colour), 3 module (ISI marked),Complete all as specified & directed by Engineer-in-Charge. Make: Legrand / Schneider / hager/Anchor(Panasonic)/Anchor(Roma)
Supply & fixing modular cover plate with frame (Black colour), 4 module (ISI marked), Complete all as specified & directed by Engineer-in-Charge. Make: Legrand / Schneider / hager/Anchor(Panasonic)/Anchor(Roma)
Supply & fixing modular cover plate with frame(Balck colour), 8 module (ISI marked), Complete all as specified & directed by Engineer-in-Charge. Make: Legrand / Schneider / hager/Anchor(Panasonic)/Anchor(Roma)
Supply & fixing modular cover plate with frame (Balck colour), 12 module (ISI marked), Complete all as specified & directed by Engineer-in-Charge. Make: Legrand / Schneider / hager/Anchor(Panasonic)/Anchor(Roma)
Supply & fixing modular cover plate with frame (Balck colour), 18 module (ISI marked), Complete all as specified & directed by Engineer-in-Charge. Make: Legrand / Schneider / hager/Anchor(Panasonic)/Anchor(Roma)
Material & Labour for point wiring using lSI marked 1.1 kV grade single core FRLSH flexible cable, conforming to IS:694- 1990, having multi-drawn thin strands of electrolytic copper conductors, conforming.to IS: 8130- 1984 and insulation conforming to IS: 5831-1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25 mm NB PVC medium grade recessed conduits, conforming to IS: 9537 (Part 3)- 1983, colour-coded as specified incIS: 11353-1985, including factory made sunken, galvanized, not less than 1.20 mm thick modular flush sheet metal enclosure having top, bottom, side and back-wall knockout for conduit entry from any direction,cconforming to IS: 14772- 2000 complete all as specified in IS: 732- 1989 and directed for One Modular 32 Amp Switch 1 way with indicator, 2 module independent, with cables 2.5 mm² size, Complete all as specified & directed by Engineer-in-Charge. Make of cable: Havells/ Finolex/ RR Kable/ KEI
Material & Labour for Sub main wiring with two runs of 4.0 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 Volts grade cable fire retardant low smoke drawn through and including PVC concealed conduit heavy duty grade ISI marked 25mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I including conduit accessories like bends, tees, junction boxes etc including 4.0 sqmm PVC insulated but unsheathed multistranded copper conductor FRLSH cable as earth continuity wire fixed, Complete all as specified & directed by Engineer-in-Charge. Make of cable: Havells/ Finolex/ RR Kable/ KEI
Material & Labour for Sub main wiring with two runs of 6.0 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 Volts grade cable fire retardant low smoke drawn through and including PVC concealed conduit heavy duty grade ISI marked 25mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I including conduit accessories like bends, tees, junction boxes etc including 6.0 sqmm PVC insulated but unsheathed multistranded copper conductor FRLSH cable as earth continuity wire fixed, Complete all as specified & directed by Engineer-in-Charge. Make of cable: Havells/ Finolex/ RR Kable/ KEI
Supply & Fixing in replacement 22 Watt LED extruded aluminium batten luminaire, nominal lumen output 2000 lm, IP20, voltage range 140-270 volts PF>0.9, wall mounted, Complete all as specified & directed by Engineer-in-Charge. Make: Philips/ Wipro/Crompton Greaves
Supply & Fixing in replacement LED Luminaires recessed mounted down lighter 18 watt 5700K system efficiency not less than 100lm/watt, thd<10% single phase including connecting cable from ceiling rose to terminal block of luminaires, Complete all as specified & directed by Engineer-in-Charge. Make :Wipro/ Philips/Crompton Greaves
Supply & Fixing in replacement 7/9 W LED spot light with multiple beam tilting angles, no UV radiation and dimmable ballast, Complete all as specified & directed by Engineer-in-Charge. Make : Philips / Wipro/ Crompton Greaves
Supply & Fixing in replacement of square shape slim recessed mounted LED down light of capacity 30 Watt (2ft x 2ft) 3000K with die cast housing finished in white powder coating, lumen not less than 120, input voltage 220-240V, Complete all as specified & directed by Engineer-in-Charge. Make : Wipro / Philips/Polycab
Supply & Fixing in replacement of Decorative, wall mounting, brushed nickle finish fixture with round glass diffuser suitable for 4 W LED filament lamp E14 base and inbuilt protection,complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of Decorative LED mirror light 10 Watt, Aluminium casting/wooden color, input voltage AC 165-265 Volts, 50 Hz, PF>0.90, Luminous efficacy not less than 0.9, Beam angle not less than 120 degree and inbuilt protection, Complete all as specified & directed by Engineer-in-Charge.
Supply & fixing in replacement BEE rated BLDC 5 star rated ceiling fan 1200mm sweep and connecting up to and including provision of 23/0.0076 flexible three core PVC insulated copper conductor cable from ceiling rose to fan etc., Complete all as specified & directed by Engineer-in-Charge. Make: Havells/Crompton/Usha/Bajaj Note: Old unserviceable ceiling fan to be deposited to E/M store yard.
Supply & Fixing engery efficient non-metalic fresh air fan having blade sweep 250mm, air delivery not less than 800 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan, Complete all as specified & directed by Engineer-in-Charge. Make: Crompton / Usha / Havells / BAJAJ Note: Old unserviceable Exhaust fan to be deposited to E/M store yard.
Supply & fixing wall mounted mounted fan 300mm sweep and connecting up to and including provision of 23/0.0076 flexible three core PVC insulated copper conductor cable from ceiling rose to fan etc., Complete all as specified & directed by Engineer-in-Charge. Make: Orient(Jazz) / Havells / Crompton /Usha
Supply and fixing sheet metal enclosure for Single pole and neutral DBs when MCBs to be used 12 way 230 V double door with 200 Amps bus bar, Complete all as specified & directed by Engineer-in-Charge. Make:Legrand/Schneider/Hager
Supply & fixing MCB Single pole 230 Volts 5-32 Amps, 10 KA 'C' curve, Complete all as specified & directed by Engineer-in-Charge. Make: Legrand/Schneider/Hager
Supply & fixing MCB Single pole & neutral 230 Volts 10 Amps, 10 KA 'C' curve, Complete all as specified & directed by Engineer-in-Charge. Make: Legrand/Schneider/Hager
Supply & fixing MCB triple pole & neutral 415 Volts 63 Amps, 10 KA 'C' curve, Complete all as specified & directed by Engineer-in-Charge. Make: Legrand/Schneider/Hager
Vijay Construction Co
KRISHNA ENGINEERING
JAY BHARAT METAL SUPPLIERS
jitendra c joisar
KEVAL ENTERPRISE
SURAJ ENTERPRISE
RAJESH ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .