| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAdmitted-Finance 110 MINI SHOPPING COMPLEX NEHRU MARKET JAMMU | L1 | Admitted-Finance | |
| 2 | L2₹4.9 L+₹2,080 (0.43%)Admitted-Finance MAIN CHOWK TABAB TILLO JAMMU | JAMMU | JAMMU AND KASHMIR | 180001 | L2 | Admitted-Finance | |
| 3 | L3₹5.0 L+₹17,490 (3.60%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Rishabh Electricals and Mechanical Works L1 | GANPATI ELECTRICAL AND MECHANICAL WORKS L2 | R M ENTERPRISES L3 |
|---|---|---|---|---|---|---|
| 1.00 | Providing of Floor Standing Air Conditioners (tower Type ) 4 Ton along with outdoor unit at Neurosurgery Operation theatre of Govt. Super Specialty Hospital of Daikin/Voltas/Blue star/ Hitachi with remote control having voltage range of 380-415V/50Hz/3 Ph, Refrigerant control(Expansion Device)-Outdoor Capillary tube, LED Display for operation status, Auto restart features, Two way Swing , Auto Protection functions, Anti dust filter, Strong dehumidification features, Copper coil, Eco friendly refrigrent-R410A and R32. The job includes providing and laying of communication copper wire size and quantity as per requirement of site. The complete job includes transportation charges of machines, carriage charges for carrying the machines to fourth floor, and all kind of taxes. | 2 | JOB | 0 ₹2,61,800 Lowest | 0 ₹2,62,400 | 0 ₹2,67,000 |
| 2.00 | Installation, testing and commissioning of 4 TR Floor Standing Air Conditioner (Tower Type) complete with matching outdoor unit. The work shall include proper installation and positioning of indoor unit and outdoor unit at designated locations, including fabrication and fixing of suitable MS platform for outdoor unit placement. The scope also includes removal of toughened glass and refixing of new glass panels, wherever required, for safe placement of the outdoor unit. Cutting of floor for laying of condensate drain pipe with proper slope, and restoration of floor including plastering and finishing after installation of drain piping shall be included. The job further includes drilling/coring through GI sheet walls and reinforced concrete OT walls for routing of insulated copper refrigerant piping, drain pipe and interconnecting power/control cables, including proper sealing of openings after completion. The job includes nitrogen pressure testing, vacuumization and additional refrigerant charging as required for extended piping length are included in the scope. The item also covers all electrical interconnections, termination, testing of system parameters, performance testing and complete commissioning of the unit The job include all materials, consumables, tools, tackles and skilled labour charges required for complete installation, testing and commissioning of the machine in all respects | 2 | JOB | 0 ₹33,000 Lowest | 0 ₹33,500 | 0 ₹36,400 |
| 3.00 | Providing of PVC drain pipes to collect drain water from indoor unit of air conditioner to nearby suitable area. The job includes cost of material , transportation and carriage charge and all kind of taxes etc | 200 | RFT | 0 ₹8,600 Lowest | 0 ₹8,800 | 0 ₹9,600 |
| 4.00 | Providing and fitting of extra copper pipe with insulation 3/4 ‘’ & 3/8 ‘’extra as per requirement of site. | 200 | RFT | 0 ₹1,29,000 Lowest | 0 ₹1,29,600 | 0 ₹1,35,000 |
| 5.00 | P/f of TPN MCB 80 Amp for air conditioner Make:Havells/L&T/ Schneider/ABB along with Gang Box . | 2 | nos | 0 ₹4,960 Lowest | 0 ₹4,980 | 0 ₹5,200 |
| 6.00 | Providing and laying of 35 sq mm FRLS PVC insulated copper wire required to make connection from existing nearby power source .The job includes cost of laying of cable, clamps, cable tray as per equirement , and and making of bus bar for forming two separate connections for two no units . Make:Havells/L&T/ Polycab/KEI | 50 | MTRS | 0 ₹42,250 Lowest | 0 ₹42,400 | 0 ₹43,500 |
| 7.00 | Supply and fixing of M.S Wall Stand duly powder coated for outdoor units | 2 | nos | 0 ₹5,900 Lowest | 0 ₹5,910 | 0 ₹6,300 |
Tender Value
₹4.9 L
EMD Value
₹10,000
Closing Date
29 May 2026, 4:00 pmClosed
XEN MH DIVISION GMCH JAMMU
XEN MH DIVISION GMCH JAMMU
Repair Renovation of Operation theatre No. 03 and 05 Urology OTs at Fourth Floor by way of fitting of Floor Standing Tower Type Air Conditioner 4 Ton each in both Operation theatres at Govt. Super Specialty Hospital, Jammu
2026_PWDJK_310188_1
MHDJ/e-NIT 48 of 2026-27
Open Tender
Repair and Maintenance Services
Turn-key
15 days
ssh jammu
as per e nit
2 documents required · 2 mandatory
₹200
XEN MH DIVISION GMCH JAMMU
₹10,000
18 Jul 2026
18 May 2026
30 May 2026
18 May 2026
29 May 2026
23 May 2026
18 May 2026 - 29 May 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Executive Engineer, Mechanical & Hospital Division GMCH Jammu.
Repair/Renovation of Operation theatre No. 03 and 05 (Urology OTs) at Fourth Floor by way of fitting of Floor Standing (Tower Type) Air Conditioner 4 Ton each in both Operation theatres at Govt. Super Specialty Hospital, Jammu.
MHDJ/e-NIT 48 of 2026-27 Dated: 18.05.2026 Due : 29.05.2026
Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Rate including GST to be quoted by the bidder Rs. P Currency Convertion against each Item Quoted Currency in INR / Other Currency Rebate on old parts in Percentage (%) if any Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category Net Cost of item Rs. P
1 Providing of Floor Standing Air Conditioners (tower Type ) 4 Ton along with outdoor unit at Neurosurgery Operation theatre of Govt. Super Specialty Hospital of Daikin/Voltas/Blue star/ Hitachi with remote control having voltage range of 380-415V/50Hz/3 Ph, Refrigerant control(Expansion Device)-Outdoor Capillary tube, LED Display for operation status, Auto restart features, Two way Swing , Auto Protection functions, Anti dust filter, Strong dehumidification features, Copper coil, Eco friendly refrigrent-R410A and R32. The job includes providing and laying of communication copper wire size and quantity as per requirement of site. The complete job includes transportation charges of machines, carriage charges for carrying the machines to fourth floor, and all kind of taxes. 2 JOB Excess(+) Full Conversion INR
2 Installation, testing and commissioning of 4 TR Floor Standing Air Conditioner (Tower Type) complete with matching outdoor unit. The work shall include proper installation and positioning of indoor unit and outdoor unit at designated locations, including fabrication and fixing of suitable MS platform for outdoor unit placement. The scope also includes removal of toughened glass and refixing of new glass panels, wherever required, for safe placement of the outdoor unit. Cutting of floor for laying of condensate drain pipe with proper slope, and restoration of floor including plastering and finishing after installation of drain piping shall be included. The job further includes drilling/coring through GI sheet walls and reinforced concrete OT walls for routing of insulated copper refrigerant piping, drain pipe and interconnecting power/control cables, including proper sealing of openings after completion. The job includes nitrogen pressure testing, vacuumization and additional refrigerant charging as required for extended piping length are included in the scope. The item also covers all electrical interconnections, termination, testing of system parameters, performance testing and complete commissioning of the unit The job include all materials, consumables, tools, tackles and skilled labour charges required for complete installation, testing and commissioning of the machine in all respects 2 JOB Excess(+) Full Conversion INR
3 Providing of PVC drain pipes to collect drain water from indoor unit of air conditioner to nearby suitable area. The job includes cost of material , transportation and carriage charge and all kind of taxes etc 200 RFT Excess(+) Full Conversion INR
4 Providing and fitting of extra copper pipe with insulation 3/4 ‘’ & 3/8 ‘’extra as per requirement of site. 200 RFT Excess(+) Full Conversion INR
5 P/f of TPN MCB 80 Amp for air conditioner Make:Havells/L&T/ Schneider/ABB along with Gang Box . 2 nos Excess(+) Full Conversion INR
6 Providing and laying of 35 sq mm FRLS PVC insulated copper wire required to make connection from existing nearby power source .The job includes cost of laying of cable, clamps, cable tray as per equirement , and and making of bus bar for forming two separate connections for two no units . Make:Havells/L&T/ Polycab/KEI 50 MTRS Excess(+) Full Conversion INR
7 Supply and fixing of M.S Wall Stand duly powder coated for outdoor units 2 nos Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
BOQ_1003734.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .